• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 2
  • Tagged with
  • 70
  • 70
  • 66
  • 34
  • 33
  • 26
  • 24
  • 19
  • 19
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Desenvolvimento de uma metodologia para calibração de câmaras de ionização de placas paralelas em feixes de raios X de energia baixa em termos de dose absorvida em água / Development of a methodology for calibration of parallel plate ionization chambers for X-ray beams of low energy in terms of absorbed dose to water

OLIVEIRA, CAMILA T. de 08 April 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-04-08T12:56:51Z No. of bitstreams: 0 / Made available in DSpace on 2016-04-08T12:56:51Z (GMT). No. of bitstreams: 0 / O objetivo deste trabalho foi estabelecer uma metodologia de calibração em termos de dose absorvida na água para câmaras de ionização de placas paralelas a serem utilizadas em feixes de radiação X de energia baixa (10 kV a 100 kV) para fins terapêuticos. Atualmente, no Brasil nenhum laboratório de calibração está oferecendo este tipo de serviço. Para o estabelecimento desta metodologia de calibração foram utilizadas duas câmaras de ionização PTW modelos 23344. Ambas as câmaras foram caracterizadas e testadas qualitativamente segundo recomendações de normas internacionais. Os testes de caracterização realizados foram: a medição da taxa de dose mínima efetiva, a curva de saturação, a eficiência da coleção de íons, a resposta quanto ao efeito da polaridade e a linearidade da câmara com a resposta. Os testes de controle de qualidade aplicados foram: estabilidade em curto e longo prazos, fuga de corrente sem irradiação, fuga de corrente após-irradiação e tempo de estabilização. Para a implantação da metodologia, foram estabelecidas as qualidades de radiação de T-10 a T-100, seguindo as recomendações do código de prática da AIEA. Desta forma, foi possível determinar a grandeza de referência, dose absorvida na água, utilizando-se as duas câmaras de ionizações e em todas as qualidades estabelecidas. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
62

Avaliação da radioatividade natural em tintas de uso comercial no Brasil / Assessment of natural radioactivity in wall paints of commercial use in Brazil

FONSECA, LEANDRO M. da 26 August 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-08-26T12:05:53Z No. of bitstreams: 0 / Made available in DSpace on 2016-08-26T12:05:53Z (GMT). No. of bitstreams: 0 / A radioatividade natural presente em solos, rochas e materiais de construção, devida ao 40K e às séries radioativas do 232Th e 238U é a principal contribuição à exposição externa aos seres humanos. Neste trabalho, determinou-se as concentrações de atividade de 226Ra (da série do 238U), 232Th e 40K presentes em 50 amostras de tintas látex de cor branca comercializadas no Brasil, especificamente, 15 do tipo econômico, 15 do tipo standard, 20 do tipo premium e em uma amostra de dióxido de titânio. As amostras foram seladas e armazenadas por um período mínimo de 30 dias para se alcançar o equilíbrio radioativo secular nas séries do 238U e do 232Th e medidas pela técnica analítica de espectrometria gama de alta resolução. As concentrações de atividade foram calculadas utilizando-se as médias ponderadas pelas incertezas do 214Pb e 214Bi para o 226Ra e médias ponderadas pelas incertezas do 228Ac, 212Pb e 212Bi para o 232Th. A concentração de atividade do 40K foi determinada pela sua transição única de 1460,8 keV. Fatores de autoatenuação gama foram calculados e utilizados para correção da concentração de atividade das amostras com densidade maior que 1,0 g.cm-3. Os índices radiológicos equivalente em rádio (Raeq), índice de concentração de atividade (Iγ), índice de risco à exposição gama interna (Hin), o índice de risco à exposição gama externa (Hex) e a taxa de dose (D) e dose efetiva anual (Def) foram calculados a partir das concentrações de atividade do 226Ra, 232Th e 40K. As concentrações de atividade de 226Ra das tintas variaram entre valores abaixo da atividade mínima detectável e 38,7 Bq.kg-1, as de 232Th variaram entre valores abaixo da atividade mínima detectável e 101,2 Bq.kg-1 e as de 40K variaram entre valores abaixo da atividade mínima detectável e 256 Bq.kg-1. O Raeq variou entre 1,41 Bq.kg-1 e 203 Bq.kg-1, o Iγ variou entre 0,0047 e 0,720, o Hin variou entre 0,0076 e 0,653 e o Hex variou entre 0,0038 e 0,549. A taxa de dose variou de 0,170 nGy.h-1 a 21,3 nGy.h-1 e a dose efetiva anual variou entre 0,83 μSv.a-1 e 104,2 μSv.a-1. Estes resultados mostram que as concentrações de atividades das tintas utilizadas neste estudo estão abaixo dos limites recomendados por Hassan et al. para Raeq (370 Bq.kg-1), pela Comissão Européia para o Iγ (limite de 2 para materiais superficiais) e pela Organização para Cooperação Econômica e Desenvolvimento para Hin e para Hex (ambos com limite de 1), para todas as 50 amostras estudadas, mostrando assim a segurança destas tintas com relação a proteção radiológica. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
63

Avaliação de dosímetros de óxido de alumínio pela técnica OSL na dosimetria de campos de fótons clínicos utilizados no tratamento radioterápico em arco modulado volumétrico / Evaluation of aluminum oxide dosimeters using OSL technique in dosimetry of clinical photom beams on volumetric modulated arc treatment

VILLANI, DANIEL 09 November 2017 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2017-11-09T11:51:03Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-09T11:51:03Z (GMT). No. of bitstreams: 0 / O tratamento utilizando Radioterapia em Arco Modulado Volumétrico é a modalidade mais moderna de radioterapia conformacional de forma que, com superposição de vários campos, as distribuições de dose forneçam uma perfeita conformação ao tumor, diminuindo a probabilidade de complicações nos tecidos normais adjacentes. Nesse sentido, muitos esforços estão sendo investidos para melhorar a conformidade de distribuição de dose, bem como a integração de técnicas de imagem para rastreamento de tumores e correção de variações inter e intrafração. Para isso, um intenso acompanhamento da qualidade dos processos e um programa de garantia de qualidade são fundamentais para a segurança dos pacientes e o cumprimento da legislação vigente; além do uso de diferentes metodologias de dosimetria para inter comparação e validação dos resultados. Este trabalho tem por objetivo avaliar e comparar o desempenho dos dosímetros OSL de óxido de alumínio (Al2O3:C) fabricados pela Landauer Inc. com os fabricados pela Rexon™ na dosimetria de feixes clínicos de fótons de energias altas empregados em radioterapia com tratamento em arco modulado volumétrico (VMAT) utilizando diferentes objetos simuladores. Os dosímetros foram caracterizados para radiação gama do 60Co e para feixes clínicos de fótons de 6 MV típicos de tratamentos por VMAT em condições de equilíbrio eletrônico e de dose máxima respectivamente. Testes de desempenho das leitoras TL e OSL utilizadas e repetibilidade das amostras foram avaliadas. Após realizados todos os testes, os dosímetros foram irradiados na simulação de diferentes tratamentos radioterápicos por VMAT e suas respostas comparadas ao sistema de planejamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das doses desse tipo de simulação de planejamento. Os dosímetros de Al2O3:C apresentaram resultados compatíveis entre si e validados pelos outros dosímetros e câmara de ionização. Em relação a melhor técnica, o sistema comercial OSL InLight apresenta maior praticidade e versatilidade para uso e aplicação na rotina clínica. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
64

Toxicity of Pulsed Beams in Radiation Therapy from a Physio-Chemical Perspective

Källén, Karin January 2021 (has links)
A significant portion of cancer patients receive radiotherapy as part of their curative or palliative treatment plan. Radiotherapy is however greatly limited by radiation induced toxicities in healthy tissue surrounding the tumour, which can lead to long-term or acute complications for a patient. In response to this issue, recent studies have considered a new technique called FLASH radiotherapy, where ultra-high dose rates have been shown to effectively reduce toxicity in normal cells whilst maintaining a tumour response equivalent to conventional dose rates. However, the exact mechanism for this effect is not yet well understood. This project seeks to investigate if certain dose delivery patterns exist where there is an increase or reduction of concentration of the toxic radical hydroxyl, which is known to play a key role in the damage of DNA in the cell, for unchanged total dose. This was done by simulating the chemical reactions which take place when water is irradiated with ionizing radiation using a simple model system consisting of water with free oxygen dissolved into it, called RadChemModel. Using basic reaction laws from chemistry, the concentration of each chemical species involved was solved for from a system of linear and non-linear ordinary differential equations. The concentration of hydroxyl was calculated as a function of time for a range of irradiation beam patterns. This model supports that there could be a difference in toxicity between FLASH and conventional beam parameters. Furthermore, a shift in the behaviour of hydroxyl suggesting reduced toxicity was observed at FLASH dose rates with very high beam pulse frequencies. However, the results obtained do not provide enough information to confirm that the concentration of hydroxyl is reduced with FLASH beam parameters. / En stor andel cancerpatienter får strålterapi som läkande eller palliativ behandling. Strålterapi kan ge upphov till allvarliga skador i den friska vävnaden i närheten av tumörområdet. För att förebygga omedelbara så väl som långsiktiga skadliga effekter av strålterapi, har nyligen pulicerade studier undersökt en ny teknik som kallas för FLASH strålterapi. Man har påvisat att ultra-höga doshastigheter kan minska strålskadorna i friska celler samtidigt som tumörkontrollen bevaras. Emellertid finns ännu ingen tillräcklig förklaring för den exakta mekanismen bakom fenomenet. Målet med detta projekt är att undersöka om en ökning eller minskning av koncentrationen hos radikalen hydroxyl, som är känd för att spela en kritisk roll i framkallandet av DNA skador, kunde upptäckas för särskilda doseringsmönster med en oförändrad total dos. Detta studerades med en enkel matematisk modell (RadChemModel) för vatten med upplöst syre. Med denna modell simulerades de kemiska reaktioner som äger rum när vatten bestrålas med joniserande strålning. Från fundamentala kemiska reaktionslagar, kunde koncentrationen av hydroxyl som funktion av tid fås genom att lösa ett system av linjära och icke-linjära ordinära differentialekvationer. Den här modellen visar att det kan finnas en skillnad i strålinducerade skador mellan FLASH och vanlig strålterapi. Resultaten från väldigt höga pulsfrekvenser med FLASH antydde också att mindre hydroxyl producerades och därmed att strålskador kan vara beroende av både doshastighet och pulsfrekvens. Däremot är resultaten inte tillräckliga för bekräfta att koncentrationen av hydroxyl är reducerad för FLASH.
65

Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques

GROPPO, DANIELA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:49Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
66

Desenvolvimento de método para caracterização de embalados de rejeitos radioativos / Development of a method for the radioisotopic characterization of waste packages

SOUZA, DAIANE C.B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:26Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
67

Caracterização dosimétrica de amostras de BeO em feixes de radiação alfa, beta e X por técnicas luminescentes / Dosimetric characterization BeO samples in alpha, beta and X radiation beams using luminescent techniques

GROPPO, DANIELA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:49Z (GMT). No. of bitstreams: 0 / No campo da medicina, a radiação ionizante é utilizada tanto para fins terapêuticos como para fins diagnósticos, englobando assim um amplo intervalo de doses de diferentes tipos de radiações. Para assegurar que a finalidade da prática esteja sendo alcançada, são necessários estudos detalhados de detectores e dispositivos que respondam a diferentes tipos de radiações. Neste trabalho foi realizada a caracterização dosimétrica de amostras de BeO utilizando as técnicas de termoluminescência (TL) e luminescência opticamente estimulada (OSL) comparando-se as respostas para as radiações alfa, beta e X e propondose um sistema adequado para sua utilização em monitoração de feixes destas radiações. Dentre os principais resultados obtidos estão: alta sensibilidade à radiação beta para ambas as técnicas empregadas, boa reprodutibilidade das respostas TL e OSL (coeficientes de variação inferiores a 5%), uma dependência energética máxima da radiação X de 28% para técnica TL, e de apenas 7% para a técnica OSL, dentro dos intervalos de energia estudados. As características dosimétricas obtidas neste trabalho mostram a possibilidade de aplicação das amostras de BeO em dosimetria das radiações ionizantes X, alfa e beta, considerando os intervalos de dose empregados, pelas técnicas de TL e OSL. Pelos resultados obtidos, as amostras de BeO apresentaram sua utilização potencial para dosimetria de feixes de radiodiagnóstico e radioterapia. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
68

Desenvolvimento de método para caracterização de embalados de rejeitos radioativos / Development of a method for the radioisotopic characterization of waste packages

SOUZA, DAIANE C.B. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:26Z (GMT). No. of bitstreams: 0 / Atualmente, a caracterização dos resíduos radioativos gerados na operação do reator nuclear de pesquisas IEA-R1 está em curso. O reator IEA-R1 é um reator do tipo piscina aberta, moderado e refrigerado por água leve, utilizando dois leitos de resinas de troca iônica e de carvão ativado para purificação de água de refrigeração. Estes meios filtrantes são substituídos quando já não são capazes de manter a qualidade da água dentro dos limites exigidos e são tratados como rejeitos radioativos. Contendo produtos de fissão, ativação e actinídeos que escapam do núcleo do reator para a água da piscina, apresentam altas taxas de dose devido à quantidade de emissores gama de meias-vidas curtas e intermediárias, emissores alfa, elementos transurânicos de meia-vida longa bem como emissores beta puros. A caracterização destes rejeitos, consequentemente, requer métodos de análise radioquímica que incluem a amostragem e o processamento das amostras, resultando em doses elevadas para os trabalhadores. Nesse contexto, o objetivo deste trabalho consistiu em correlacionar os resultados das análises radioquímicas de amostras de rejeitos, com os resultados das medições radiométricas, utilizando a modelagem das taxas de dose em diferentes distâncias da superfície dos embalados. As taxas de dose medidas foram comparadas com os resultados de cálculos . Massa, volume e geometria das fases sólidas e líquidas de cada um dos tambores também foram determinadas, uma vez que o teor de água varia amplamente entre diferentes tambores, e são essenciais para estimar as atividades totais em cada tambor. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
69

Estudo de casos clínicos em radioterapia através do sistema de planejamento AMIGOBrachy / Clinical cases study on radiotherapy using treatment planning system AMIGOBrachy

ANGELOCCI, LUCAS V. 21 December 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-12-21T11:30:16Z No. of bitstreams: 0 / Made available in DSpace on 2016-12-21T11:30:16Z (GMT). No. of bitstreams: 0 / O sucesso de uma radioterapia depende do correto planejamento da dose a ser entregue ao volume alvo. Na braquiterapia, modalidade da radioterapia onde um radioisótopo selado é implantado intracavitariamente ou intersticialmente no paciente, há menos avanços em sistemas de planejamento de tratamento computacionais do que na teleterapia, amplamente mais utilizada nos serviços típicos. Porém, a braquiterapia, quando aplicável, é preferível por poupar tecidos sadios vizinhos de uma dose desnecessária. O AMIGOBrachy, um sistema de planejamento para braquiterapia de interface amigável, compatibilidade com outros sistemas comerciais em uso e integrado ao código MCNP6 (Monte Carlo N-Particle Transport Code v. 6) foi desenvolvido no Centro de Engenharia Nuclear do Instituto de Pesquisas Energéticas e Nucleares (CEN-IPEN) e atualmente está em processo de validação. Este trabalho contribuiu para este processo, avaliando três diferentes casos clínicos através do AMIGOBrachy com o formalismo do TG43 da AAPM (Associação Americana de Física Médica), protocolo que rege a dosimetria em braquiterapia, e comparando seus resultados com as distribuições de dose calculadas por outros sistemas comerciais consagrados: Varian BrachyVision TM (Varian Medical Systems; Palo Alto, CA, EUA) e Nucletron Oncentra® (Elekta; Estocolmo, Suécia). Os resultados obtidos estão dentro de uma faixa de concordância de ±10%, estando mais discrepantes em regiões muito próximas do aplicador, onde os sistemas de planejamento comerciais e o AMIGOBrachy divergem devido aos diferentes métodos de cálculo. Em pelo menos dois terços da região de interesse, porém, a dose concordou em uma faixa de ±3% para os três casos. Também foram realizadas simulações utilizando o formalismo do TG186 da AAPM, que considera heterogeneidades no tecido, para avaliar o impacto dos mesmos na dose. Em adição ao processo de validação, também foi realizado um estudo em braquiterapia oftálmica para posterior inserção de um módulo adicional ao AMIGOBrachy; para isso, um modelo de olho humano foi desenvolvido utilizando geometria UM (Unstructured Mesh), para validação com o código MCNP6, que apenas nesta versão demonstra um novo recurso capaz de simular uma geometria híbrida: parcialmente analítica, parcialmente UM. O modelo considera dez diferentes estruturas no olho humano: esclera, coroide, retina, corpo vítreo, córnea, câmara anterior, lente, nervo óptico, parede do nervo óptico, e um tumor definido de forma arbitrária crescendo da superfície externa do globo ocular em direção ao seu centro. Os resultados foram comparados com um modelo de olho puramente analítico modelado com o MCNP6 e tomado como referência. Os resultados foram satisfatórios em todas as simulações desenvolvidas, exceto para as estruturas do nervo óptico e sua parede, que devido ao seu pequeno tamanho e distância da fonte, mostraram erros relativos maiores, mas ainda menores que 10%, e não representam problema de preocupação clínica uma vez que recebem doses muito pequenas. Discutiu-se também a eficácia e problemas encontrados nessa nova capacidade do código MCNP de simular geometrias híbridas, uma vez que é recente e ainda apresenta deficiências, que tiveram que ser contornadas no presente trabalho. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
70

Evolução das doses no ambiente do Reator IEA-R1 e tendências com base nos resultados atuais / The evolution of doses in THE IEA-R1 reactor environment and tendencies based on the current results

TOYODA, EDUARDO Y. 26 August 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-08-26T11:43:46Z No. of bitstreams: 0 / Made available in DSpace on 2016-08-26T11:43:46Z (GMT). No. of bitstreams: 0 / O Ipen/Cnen-SP possui um Reator de Pesquisa(IEA-R1) em operação desde 1957. Ele utiliza água leve como blindagem, moderador e como fluido refrigerante, o volume desta piscina é de 273m3. Até 1995 a operação do Reator era descontinua, ou seja, operava diariamente sendo desligado no final do dia, a uma potência de 2,0 MW. A partir daquele ano, após algumas modificações de segurança, o Reator passou a operar de forma continua, ou seja, de segunda-feira a quarta-feira sem ser desligado, totalizando 64 horas semanais. A potência também foi aumentando até 4,5 MW em 2012. Em virtude dessas alterações, a saber, operação contínua e do aumento da potência, as doses dos trabalhadores aumentaram e por isso foram realizados vários estudos para diminui-las. Estudos demonstraram que uma das principais limitações para operação de um reator em potência elevada, provém das radiações gama emitidas pelo sódio-24. Outros elementos como magnésio-27, Alumínio-28, Argônio-51, contribuem de forma considerável para a atividade da água da piscina. A introdução de uma camada de água quente em sua superfície, estável e isenta de elementos radioativos com 1,5m a 2m de espessura constituiria uma blindagem às radiações provenientes dos elementos radioativos dissolvidos na água. Estudos de otimização provaram que a instalação da camada quente não era necessária para o regime e potência atual de operação do Reator, pois outros procedimentos adotados eram mais eficazes. A partir desta decisão o serviço de Proteção Radiológica do Reator IEA-R1, montou um programa de avaliação das doses para certificar-se de que elas se mantinham em valores razoáveis baseados em princípios estabelecidos em normas nacionais e internacionais. O intuito deste trabalho é realizar uma análise das doses individuais dos IOE (Individuo Ocupacionalmente Expostos), considerando as mudanças no regime de operação do Reator e sugerir opções de proteção e segurança, viáveis em primeira instância, para reduzir as doses analisadas, visando se chegar aos níveis de referencia de 3 mSv/ano adotados pela instalação em apreço. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.077 seconds