• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 1
  • Tagged with
  • 12
  • 12
  • 10
  • 10
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelos preditivos da composição corporal utilizando a antropometria e a absortometria de raios-x de dupla energia

Patrícia Siqueira Tavares, Ana 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T23:02:12Z (GMT). No. of bitstreams: 2 arquivo4039_1.pdf: 6838635 bytes, checksum: bce9817754c654c990a61050cec60f62 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Diversas são as equações encontradas na literatura, específicas ou generalizadas, no intuito de predizer a densidade corporal e/ou os componentes da composição corporal, percentual de gordura (%G), massa gorda (MG) e massa magra (MM). São empregados desde métodos simples, como a antropometria, até técnicas mais sofisticadas como é o caso da absortometria de raios-x de dupla energia (DXA) que vem sendo reconhecida como método padrão ouro . As diferenças entre as populações, o aumento cada vez maior da prevalência do sobrepeso, da obesidade e das doenças crônico-degenerativas em homens adultos jovens, aponta para a necessidade de pesquisas em diferentes regiões nas diversas fases da vida do homem. Nesse contexto, objetiva-se descrever aspectos envolvidos no processo de desenvolvimento, validação e possibilidades de aplicação das equações preditivas da gordura corporal, estabelecendo uma comparação dos valores do %G, MG e MM estimados pelos modelos preditivos e mensurados pela DXA. O estudo tem delineamento transversal. Participaram como sujeitos 45 homens com idade entre 20 a 30 anos, avaliados no Laboratório de Avaliação de Performance Humana da Universidade de Pernambuco Recife/PE e no Laboratório Albuquerque do Ó, Recife PE, no período de dezembro/2004 a agosto/2005. As medidas antropométricas utilizadas foram: massa corporal total, estatura, circunferência da cintura, circunferência do quadril, dobras cutâneas centralizadas (SE: subescapular, SI: supra-ilíaca, AM: axilar média e ABD: abdominal) e periféricas (TR: tríceps, BI: bíceps, CO: coxa e PE: perna), os índices antropométricos: índice de massa corporal (IMC), relação cintura quadril (RCQ), índice cintura altura (ICA) e %G, MG, MM mensurados pelo DXA dos membros superiores, inferiores, tronco e total. As análises foram realizadas no pacote estatístico SPSS versão 11.0, adotando-se um nível de significância de 5%. Os critérios de validação cruzada foram os sugeridos por Lohman (1992), além da análise dos escores residuais proposta por Bland e Altman (1986), a regressão linear simples e a Receiver Operating Characteristic (ROC). Foi realizada a validação cruzada de 7 modelos preditivas, sendo apenas validada a de Durnin e Womersley. Os resultados demonstraram forte associação entre o ICA e o %G de membros, tronco e total; a maior área sob a curva ROC foi a do ICA, 0,87 (0,72-0,99). Assim sendo, a equação recomendada para ser utilizada no grupo estudado foi de Durnin e Womersley; o ICA revelou ser o indicador antropométrico mais indicado para explicar a variação do %G por compartimento e apresentou maior poder discriminatório de risco cardiovascular. O componente MM demonstrou menor variabilidade em relação ao %G e a MG, sendo sugerido como variável explicativa nos modelos preditivos e o componente da composição corporal indicado para ser utilizado como forma de reduzir a proporção corporal
2

Simulação de mamografia digital por dupla energia para imagens quantitativas / Dual-Energy Digital Mammography: Study and Optimization Using Monte-Carlo Simulation.

Godeli Neto, Julio 01 August 2016 (has links)
A técnica de mamografia por dupla energia tem se mostrado uma ferramenta eficiente para aumentar a visualização e detecção de microcalcificações, uma vez que permite, por meio da combinação de imagens obtidas com energias diferentes (baixa e alta energia), suprimir o ruído estrutural. Por outro lado, pesquisas recentes sugerem que esta técnica permite a obtenção de imagens quantitativas das espessuras de microcalcificações e frações glandulares presentes nos tecidos mamários. O presente trabalho tem como objetivo, o estudo e otimização de imagens quantitativas obtidas através da técnica de mamografia por dupla energia. Este estudo foi realizado por simulação computacional, utilizando o código PENELOPE (Penetrarion and Energy Loss of Positrons and Electrons), o qual foi adaptado para fornecer imagens mamográficas digitais e dados relevantes para o estudo da formação da imagem, bem como fornecer as grandezas dosimétricas de interesse nesta técnica. Para isto, a geometria de um típico exame clínico foi simulado,considerando desde o equipamento mamográfico digital (fonte, placa compressora, suporte e detector), até a mama (pele, gordura, tecidos glandulares e microcalcificações). A validação das adaptações ao código foi feita através da comparação entre os valores de razão espalhado-primário (SPR) e dose glandular normalizada (DgN) gerados neste trabalho, com aqueles presentes na literatura. Finalmente, todos os elementos da cadeia da formação de imagens quantitativas foram implementados e avaliados, consistindo de (i) um algoritmo de pré-processamento, que permite corrigir a contribuição do espalhamento nas imagens, com desempenho superior a 95%; (ii) um algoritmo de pós-processamento nas imagens combinadas (baixa e alta energia) que permite corrigir o aumento do ruído decorrente do pré-processamento e da combinação das imagens, com desempenho de 90%. Os resultados de otimização foram adquiridos para diversas características de mama (espessuras de 2 a 6 cm e frações glandulares entre 25 e 75%) e avaliados para diferentes tamanhos de calcificações. As combinações ótimas de energias (baixa;alta) para mamas com espessuras de 2, 4 e 6 cm foram (16;62), (19;56) e (22;56) keV, respectivamente. As combinações escolhidas como ótimas conseguiram estimar as espessuras das microcalcificações com exatidão superior a 92% e a fração glandular com exatidão superior a 95%. / The dual-energy mammography technique has proven to be an efficient tool to increase the visualization and detection of microcalcifications, since it allows, by combining images obtained with different energies (low and high energy), suppress the structural noise. Moreover, recent researches suggests that this technique would allow obtaining quantitative images of microcalcifications thicknesses or glandular fractions present in the breast tissues. This current work aims the study and optimization of quantitative images obtained through dual-energy mammography technique, and was carried out by computer simulation using the PENELOPE code (Penetrarion and Energy Loss of Positron and Electrons), wich was adapted to provide digital mammographic images, and relevant data used in the study of the formation of images and provide the dosimetric quantities of interest in this technique. For this, the model of a typical clinical examination was simulated, from considering the digital mammography equipment (source, compressing plate holder and detector), until the breast (skin, fat, glandular tissues and calcifications). The validation of code adaptation was evaluated by comparing the values of scatter-primary ratio (SPR) and normalized glandular dose (DgN) acquired in this work, with the data in the literature. Finally, all elements of the data chain of the quantitative images were implemented and evaluated, which consist of (i) a pre-processing algorithm that corrects the scattering contribution in the images, with a performance superior to 95%; (ii) a post-processing algorithm in the combined images (low and high energy) that allows to correct the increased noise from the pre-processing and from the combination of the images, with a performance of 90%. The optimization results were obtained for different breast characteristics and evaluated in different calcifications sizes. The optimum combinations of energies (low;high) for breasts with thicknesses of 2, 4 and 6 cm were (16;62), (19;56) and (22;56) keV , respectively. The combinations chosen as optimal was able to estimate the thickness of microcalcifications with an accuracy higher than 92% and the glandular fraction with an accuracy upper to 95% .
3

Comparação de diferentes métodos na avaliação da massa livre de gordura e massa gorda nos pacientes em diálise.

Reis, Nayrana Soares do Carmo January 2019 (has links)
Orientador: Fracieli Cristina Delatim Vannini / Resumo: INTRODUÇÃO: A depleção proteico-energética está relacionada à piora da qualidade de vida e menor sobrevivência do paciente em diálise. A avaliação da composição corporal, especialmente da massa livre de gordura (MLG) e massa gorda (MG), é importante para a predição de desfechos nesses indivíduos. O objetivo deste trabalho foi comparar as medidas de MLG e MG obtidas por antropometria, bioimpedância unifrequencial (BIAUNI) e bioimpedância multifrequencial (BIAMULT), utilizando a densitometria de raio-X de dupla energia (DXA) como padrão de referência, em pacientes submetidos a tratamento dialítico. CASUÍSTICA E MÉTODOS: Estudo transversal realizado com pacientes adultos em tratamento regular por hemodiálise (HD) ou diálise peritoneal (DP). As avaliações foram realizadas por antropometria, BIAUNI, BIAMULT e DXA no mesmo momento. Para comparação entre os valores obtidos por esses métodos com a DXA foram utilizados testes de correlação de Person (r), Coeficiente de Correlação Intraclasse (ICC) e análise de concordância de Bland-Altman. RESULTADOS: A casuística foi composta de 112 pacientes adultos (62 em HD e 50 em DP) com média de idade de 55,5±14,5 anos (HD) e 55,1±16,3 anos (DP). Os grupos (HD e DP) foram semelhantes quanto à maioria das características, embora pacientes em DP tenham apresentado maior índice de hiperidratação (OH) (0,8±1,1 vs. -0,9±1,3, p<0,001), maior percentual de OH/AEC (água extracelular) (5,0±7,2% vs. -7,4±11,7%, p<0,001) e menor concentração de albumina s... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: INTRODUCTION: Protein-energy wasting is related to impairment of quality of life and lower survival of dialysis patients. The evaluation of body composition, especially fat free mass (MLF) and fat mass (MG), is important for the prediction of outcomes in these individuals. The objective of this study was to compare the MLG and MG measurements obtained by anthropometry, unifrequency bioimpedance (BIAUNI) and multifrequency bioimpedance (BIAMULT), using Dual-energy X-ray absorptiometry (DXA) as the reference method in patients submitted to dialysis treatment. MATERIAL AND METHODS: A cross-sectional study with adult patients undergoing regular hemodialysis (HD) or peritoneal (PD) dialysis. The evaluations were performed by anthropometry, BIAUNI, BIAMULT and DXA at the same time. To compare the values obtained by these methods with DXA, we used correlation tests of Person (r), Intraclass Correlation Coefficient (ICC) and Bland-Altman concordance analysis. RESULTS: The sample consisted of 112 adult patients (62 in HD and 50 in PD) with mean age of 55.5 ± 14.5 years (HD) and 55.1 ± 16.3 years (PD). The groups HD and DP were similar for most of the characteristics, although patients with PD had a higher hyperhydration index (OH) (0.8±1.1 vs. -0.9±1.3, p <0.001), higher OH/extracellular water (ECW) (5.0±7.2% vs. - 7.4±11.7%, p<0.001) and a lower serum albumin concentration (3.6±0.4g/dl vs. 4.0±0.4g/dl, p<0.001). Considering the sample of patients from both groups, all methods showed ... (Complete abstract click electronic access below) / Doutor
4

Simulação de mamografia digital por dupla energia para imagens quantitativas / Dual-Energy Digital Mammography: Study and Optimization Using Monte-Carlo Simulation.

Julio Godeli Neto 01 August 2016 (has links)
A técnica de mamografia por dupla energia tem se mostrado uma ferramenta eficiente para aumentar a visualização e detecção de microcalcificações, uma vez que permite, por meio da combinação de imagens obtidas com energias diferentes (baixa e alta energia), suprimir o ruído estrutural. Por outro lado, pesquisas recentes sugerem que esta técnica permite a obtenção de imagens quantitativas das espessuras de microcalcificações e frações glandulares presentes nos tecidos mamários. O presente trabalho tem como objetivo, o estudo e otimização de imagens quantitativas obtidas através da técnica de mamografia por dupla energia. Este estudo foi realizado por simulação computacional, utilizando o código PENELOPE (Penetrarion and Energy Loss of Positrons and Electrons), o qual foi adaptado para fornecer imagens mamográficas digitais e dados relevantes para o estudo da formação da imagem, bem como fornecer as grandezas dosimétricas de interesse nesta técnica. Para isto, a geometria de um típico exame clínico foi simulado,considerando desde o equipamento mamográfico digital (fonte, placa compressora, suporte e detector), até a mama (pele, gordura, tecidos glandulares e microcalcificações). A validação das adaptações ao código foi feita através da comparação entre os valores de razão espalhado-primário (SPR) e dose glandular normalizada (DgN) gerados neste trabalho, com aqueles presentes na literatura. Finalmente, todos os elementos da cadeia da formação de imagens quantitativas foram implementados e avaliados, consistindo de (i) um algoritmo de pré-processamento, que permite corrigir a contribuição do espalhamento nas imagens, com desempenho superior a 95%; (ii) um algoritmo de pós-processamento nas imagens combinadas (baixa e alta energia) que permite corrigir o aumento do ruído decorrente do pré-processamento e da combinação das imagens, com desempenho de 90%. Os resultados de otimização foram adquiridos para diversas características de mama (espessuras de 2 a 6 cm e frações glandulares entre 25 e 75%) e avaliados para diferentes tamanhos de calcificações. As combinações ótimas de energias (baixa;alta) para mamas com espessuras de 2, 4 e 6 cm foram (16;62), (19;56) e (22;56) keV, respectivamente. As combinações escolhidas como ótimas conseguiram estimar as espessuras das microcalcificações com exatidão superior a 92% e a fração glandular com exatidão superior a 95%. / The dual-energy mammography technique has proven to be an efficient tool to increase the visualization and detection of microcalcifications, since it allows, by combining images obtained with different energies (low and high energy), suppress the structural noise. Moreover, recent researches suggests that this technique would allow obtaining quantitative images of microcalcifications thicknesses or glandular fractions present in the breast tissues. This current work aims the study and optimization of quantitative images obtained through dual-energy mammography technique, and was carried out by computer simulation using the PENELOPE code (Penetrarion and Energy Loss of Positron and Electrons), wich was adapted to provide digital mammographic images, and relevant data used in the study of the formation of images and provide the dosimetric quantities of interest in this technique. For this, the model of a typical clinical examination was simulated, from considering the digital mammography equipment (source, compressing plate holder and detector), until the breast (skin, fat, glandular tissues and calcifications). The validation of code adaptation was evaluated by comparing the values of scatter-primary ratio (SPR) and normalized glandular dose (DgN) acquired in this work, with the data in the literature. Finally, all elements of the data chain of the quantitative images were implemented and evaluated, which consist of (i) a pre-processing algorithm that corrects the scattering contribution in the images, with a performance superior to 95%; (ii) a post-processing algorithm in the combined images (low and high energy) that allows to correct the increased noise from the pre-processing and from the combination of the images, with a performance of 90%. The optimization results were obtained for different breast characteristics and evaluated in different calcifications sizes. The optimum combinations of energies (low;high) for breasts with thicknesses of 2, 4 and 6 cm were (16;62), (19;56) and (22;56) keV , respectively. The combinations chosen as optimal was able to estimate the thickness of microcalcifications with an accuracy higher than 92% and the glandular fraction with an accuracy upper to 95% .
5

Avaliação da confiabilidade e concordância de métodos de avaliação da composição corporal em mulheres no período reprodutivo / Evaluation of reliability and consistency of body composition assessment methods in women in reproductive period

Silva, Rafael Costa 12 January 2016 (has links)
Objetivos: Avaliar a composição corporal através da medida das dobras cutâneas (DC) intra e inter observador em mulheres na fase reprodutiva. Estimar a confiabilidade de dois protocolos de medidas de dobras cutâneas com o método Absorciometria Radiológica de Dupla Energia (DEXA). Métodos: A amostra foi composta por 90 mulheres com faixa etária de 18 a 37 anos, com Índice de Massa Corporal entre 18 e <= 39,9 Kg/m². A reprodutibilidade dos métodos foram avaliados pelos coeficientes de correlação de concordância (CCC) e coeficiente de Saint Laurent e pelos limites de concordância e gráficos de Bland-Altman. Resultados: A comparação intra observador foi excelente (CCC = 0,99) para os valores das medidas de DC tricipital, supraíliaca, coxa, soma das dobras e percentual de gordura. O mesmo ocorreu na comparação inter observador (CCC = 0,99). As medidas das DC tricipital foram as que apresentaram maior CCC (0,98), seguido da medida da coxa (0,90), e a medida da DC da suprailíaca foi a menor (0,89). A soma das DC e o percentual de gordura tiveram valores de 0,95. Já os protocolos de medidas de DC comparados entre si e com o padrão ouro DEXA, obtiveram valores de concordância baixa (0,35). Conclusões: Nossos achados mostraram que a comparação intra e inter observador foi satisfatória, contribuindo para a reprodutibilidade das medidas de DC. Os protocolos de avaliação das DC não tiveram concordância quando comparados com a DEXA / Objectives: Assessing body composition by measuring the intra and inter observer skin folds in women in the reproductive phase and estimate the reliability of two protocols skinfold measures with radiographic absorptiometry method of dual energy absorptiometry (DEXA). Methods: The sample consisted of 170 women aged 18-37 years with body mass index between 18 and <= 39.9 kg / m². The reproducibility of methods and skinfold thickness were evaluated by the coefficient of concordance correlation (CCC) and coefficient of Saint Laurent and the limits of agreement and Bland-Altman. Results: Comparison intra observer was excellent with the same values of the CCC (0.99) for the measurements of skinfold thickness of the triceps, suprailiac, thigh and fat percentage. The same occurred in the comparison inter observer (CCC = 0.99). The measures of skinfold thickness of the triceps showed the greatest CCC (0.98), followed by thigh (0.90), and the suprailiac was the lowest (0.89). The sum of the measurements of skinfold thickness and the percentage of fat had CCC values of 0.95. Already the reliability of two protocols skinfold thickness measures compared with the gold standard DEXA method was low (CCC = 0.35). Conclusions: Our findings showed that compared intra and inter observer was satisfactory, contributing to the reproducibility of skin folds. Assessment protocols skinfold did not have agreement when compared with DEXA
6

Avaliação da técnica de impedância bioelétrica na identificação das alterações da composição corporal em mulheres no período pós-parto / Assessment of body composition changes in women in the postpartum period by bioelectrical impedance

Ana Cristina Teixeira Santos 20 December 2013 (has links)
Este trabalho teve como objetivo verificar se a técnica de impedância bioelétrica (IB) identifica as modificações da composição corporal em mulheres no período pós-parto. Participaram do estudo 47 mulheres (&#8805; 18 anos), nas quais foram avaliadas massa livre de gordura (MLG), massa gorda (MG) e percentual de gordura corporal (%GC) pelos equipamentos IB_Tanita BC 533; IB_RJL 101 e por absorciometria de raio X de dupla energia (DXA). Todas as avaliações foram feitas no mesmo dia. Posteriormente, as mulheres foram categorizadas em dois grupos: com perda ponderal (n= 24) e com ganho ponderal (n= 22). Os valores médios das alterações da composição corporal (CC), foram comparados intra-métodos e em relação ao método padrão-ouro (DXA) através de teste T-pareado. A concordância entre as diferenças das alterações da CC obtidas pelas IB e DXA foi avaliada pelo método de Bland & Altman e pelo coeficiente de correlação intraclasse (CCI). A média &#61617; desvio padrão de idade foi de 26,7 &#61617; 5,2 anos e o tempo médio da captação no pós-parto para a primeira avaliação foi de 2,6 &#61617; 2,0 meses e 8,0 &#61617; 2,7 meses para a segunda avaliação. A média de massa corporal (MC) foi de 74,6 &#61617; 11,4 kg na primeira avaliação e 75,1 &#61617; 12,6 kg na segunda avaliação, correspondendo a um valor de índice de massa corporal (IMC) de 28,8 &#61617; 4,0 kg/m2 e 29,0 &#61617; 4,6 kg/m2, respectivamente. O %GC medido pela DXA foi de 40,1 &#61617; 4,9 % para a primeira avaliação e de 41,0 &#61617; 5,2 %, para a segunda avaliação, representando uma MG de 30,2 &#61617; 6,6 kg e de 30,9 &#61617; 8,0 kg, respectivamente. Ambas as IB subestimaram a alteração do % GC (-0,7 % para IB_Tanita e -1,1% para IB_RJL) e MG (-0,6 kg para IB_Tanita e -1,0 kg IB_RJL) em relação ao DXA. Por sua vez, as alterações de MLG foram superestimadas 0,8 kg pela IB_Tanita e 1,0 kg IB_RJL. Houve boa concordância (CCI &#8805; 0,75) entre as alterações identificadas para MG pela IB_Tanita e por DXA e satisfatória pela IB_RJL. Dessa forma o presente estudo verificou um desempenho satisfatório da técnica de IB em identificar as alterações da MG gorda e que a IB_Tanita mostrou-se melhor que a IB_RJL na estimativa da alteração desse componente corporal nesse grupo de mulheres pós-parto. / The aim of the present study is to assure that the measurement of the bioelectrical impedance (IB) identifies the changes in the body composition of postpartum women. Forty-seven women (&#8805; 18 years of age) were enrolled in the study. Body composition (BC) - fat free mass (FFM), fat mass (FM) and percentage body fat (%BF) - was obtained by two IB devices (Tanita BC 533 and RJL 101) and DXA. All measurements were performed at the same day in two different postpartum moments. The women were categorized in two groups: with weight loss (WWL, n= 24) and with weight gain (WWG, n= 22). Pair T-test was used to compare mean difference values within methods and DXA. Bland & Altman plots and intraclass correlation coefficients (ICC) were used to evaluate the agreement between body composition changes obtained by both IB and DXA. The first and second visits for BC measurements occurred 2,6 &#61617; 2,0 months e 8,0 &#61617; 2,7 months after delivery, respectively. Mean ( SD) age was 26.7 &#61617; 5.2 years and body mass was 74.6 &#61617; 11.4 kg at the first visit and 75.1 &#61617; 12.6 kg at the second visit. Women were overweight in both visits (BMI= 28.8 &#61617; 4,0kg/m2 e 29.0 &#61617; 4.6 kg/m2). % BF measured by DXA at the first visit was 40.1 &#61617; 4.9% and at the second visit was 41.0 &#61617; 5.2% yielding on average a FM of 30.2 &#61617; 6,6 kg and 30,9 &#61617; 8,0 kg, respectively.. IB_Tantia yelded lower mean values for FFM and FM compare to DXA mean values, except for %BF. Both IB underestimated %BF (-0.7% for Tanita and -1.1% for RJL) and FM changes (-0.6 kg for Tanita and -1.0 for RJL) compared to DXA changes. On the other hand FFM changes were overestimated by Tanita (0,8 kg) and RJL (1,0 kg). There was a good agreement (CCI &#8805; 0.75) between FM changes measured by IB_Tanita and DXA and a fair agreement for IB_RJL. Therefore the IB technique was able to identified FM changes, and IB_Tanita showed a better performance than IB_RJL on the estimation of FM changes in these postpartum women.
7

Avaliação da técnica de impedância bioelétrica na identificação das alterações da composição corporal em mulheres no período pós-parto / Assessment of body composition changes in women in the postpartum period by bioelectrical impedance

Ana Cristina Teixeira Santos 20 December 2013 (has links)
Este trabalho teve como objetivo verificar se a técnica de impedância bioelétrica (IB) identifica as modificações da composição corporal em mulheres no período pós-parto. Participaram do estudo 47 mulheres (&#8805; 18 anos), nas quais foram avaliadas massa livre de gordura (MLG), massa gorda (MG) e percentual de gordura corporal (%GC) pelos equipamentos IB_Tanita BC 533; IB_RJL 101 e por absorciometria de raio X de dupla energia (DXA). Todas as avaliações foram feitas no mesmo dia. Posteriormente, as mulheres foram categorizadas em dois grupos: com perda ponderal (n= 24) e com ganho ponderal (n= 22). Os valores médios das alterações da composição corporal (CC), foram comparados intra-métodos e em relação ao método padrão-ouro (DXA) através de teste T-pareado. A concordância entre as diferenças das alterações da CC obtidas pelas IB e DXA foi avaliada pelo método de Bland & Altman e pelo coeficiente de correlação intraclasse (CCI). A média &#61617; desvio padrão de idade foi de 26,7 &#61617; 5,2 anos e o tempo médio da captação no pós-parto para a primeira avaliação foi de 2,6 &#61617; 2,0 meses e 8,0 &#61617; 2,7 meses para a segunda avaliação. A média de massa corporal (MC) foi de 74,6 &#61617; 11,4 kg na primeira avaliação e 75,1 &#61617; 12,6 kg na segunda avaliação, correspondendo a um valor de índice de massa corporal (IMC) de 28,8 &#61617; 4,0 kg/m2 e 29,0 &#61617; 4,6 kg/m2, respectivamente. O %GC medido pela DXA foi de 40,1 &#61617; 4,9 % para a primeira avaliação e de 41,0 &#61617; 5,2 %, para a segunda avaliação, representando uma MG de 30,2 &#61617; 6,6 kg e de 30,9 &#61617; 8,0 kg, respectivamente. Ambas as IB subestimaram a alteração do % GC (-0,7 % para IB_Tanita e -1,1% para IB_RJL) e MG (-0,6 kg para IB_Tanita e -1,0 kg IB_RJL) em relação ao DXA. Por sua vez, as alterações de MLG foram superestimadas 0,8 kg pela IB_Tanita e 1,0 kg IB_RJL. Houve boa concordância (CCI &#8805; 0,75) entre as alterações identificadas para MG pela IB_Tanita e por DXA e satisfatória pela IB_RJL. Dessa forma o presente estudo verificou um desempenho satisfatório da técnica de IB em identificar as alterações da MG gorda e que a IB_Tanita mostrou-se melhor que a IB_RJL na estimativa da alteração desse componente corporal nesse grupo de mulheres pós-parto. / The aim of the present study is to assure that the measurement of the bioelectrical impedance (IB) identifies the changes in the body composition of postpartum women. Forty-seven women (&#8805; 18 years of age) were enrolled in the study. Body composition (BC) - fat free mass (FFM), fat mass (FM) and percentage body fat (%BF) - was obtained by two IB devices (Tanita BC 533 and RJL 101) and DXA. All measurements were performed at the same day in two different postpartum moments. The women were categorized in two groups: with weight loss (WWL, n= 24) and with weight gain (WWG, n= 22). Pair T-test was used to compare mean difference values within methods and DXA. Bland & Altman plots and intraclass correlation coefficients (ICC) were used to evaluate the agreement between body composition changes obtained by both IB and DXA. The first and second visits for BC measurements occurred 2,6 &#61617; 2,0 months e 8,0 &#61617; 2,7 months after delivery, respectively. Mean ( SD) age was 26.7 &#61617; 5.2 years and body mass was 74.6 &#61617; 11.4 kg at the first visit and 75.1 &#61617; 12.6 kg at the second visit. Women were overweight in both visits (BMI= 28.8 &#61617; 4,0kg/m2 e 29.0 &#61617; 4.6 kg/m2). % BF measured by DXA at the first visit was 40.1 &#61617; 4.9% and at the second visit was 41.0 &#61617; 5.2% yielding on average a FM of 30.2 &#61617; 6,6 kg and 30,9 &#61617; 8,0 kg, respectively.. IB_Tantia yelded lower mean values for FFM and FM compare to DXA mean values, except for %BF. Both IB underestimated %BF (-0.7% for Tanita and -1.1% for RJL) and FM changes (-0.6 kg for Tanita and -1.0 for RJL) compared to DXA changes. On the other hand FFM changes were overestimated by Tanita (0,8 kg) and RJL (1,0 kg). There was a good agreement (CCI &#8805; 0.75) between FM changes measured by IB_Tanita and DXA and a fair agreement for IB_RJL. Therefore the IB technique was able to identified FM changes, and IB_Tanita showed a better performance than IB_RJL on the estimation of FM changes in these postpartum women.
8

Sarcopenia em idosos: revisão, prevalência, concordância entre métodos diagnósticos e antropometria como proposta de rasatreamento / Sarcopenia in the elderly: review, prevalence, agreement between diagnostic methods and anthropometry as a screening proposition

Pagotto, Valéria 21 June 2013 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2014-12-01T16:58:26Z No. of bitstreams: 2 Tese - Valéria Pagotto - 2013.pdf: 1825466 bytes, checksum: f97e4cc29d226317b6a69fbcc4e88f19 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2014-12-04T14:32:55Z (GMT) No. of bitstreams: 2 Tese - Valéria Pagotto - 2013.pdf: 1825466 bytes, checksum: f97e4cc29d226317b6a69fbcc4e88f19 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-12-04T14:32:55Z (GMT). No. of bitstreams: 2 Tese - Valéria Pagotto - 2013.pdf: 1825466 bytes, checksum: f97e4cc29d226317b6a69fbcc4e88f19 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-06-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The aim of this study was to review methods and diagnostic criteria for sarcopenia available in the literature to estimate the prevalence and concordance between them, in a sample of elderly Goiânia, and propose anthropometry for screening sarcopenia. To review methods we used the recommendations for systematic review and meta-analysis of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement. For other purposes, we used a subsample of 132 elderly Senior Project/ Goiânia, selected in proportion to the Sanitation Districts of Goiânia. The data were collected by staff previously trained and standardized. Sarcopenia was analyzed by mass and muscle strength. The mass mucular was estimated by dual X-ray absorptiometry (DEXA), bioelectrical impedance analysis (BIA) and anthropometry, and muscle strength through hand grip strength (FPP). Analyses were performed in STATA 12.0, comparison of means and proportions, estimation of prevalence and prevalence ratio, Kappa, calculation of sensitivity and specificity analysis and ROC (receiver operator characteristic) curve. The project was approved by the Ethics Committee of the Federal University of Goiás. In 28 prevalence studies reviewed were found three methods for the diagnosis of sarcopenia: DEXA BIA and anthropometry with significant variations in prevalence as sex and the method adopted. Applying the diagnostic criteria found in the subsample Elderly Project/ Goiânia, the prevalence of sarcopenia ranged from 60.6% to 8.3% for the criteria of muscle mass and 54.2% to 48.8% for the strength, increasing in age and is more prevalent in men by criteria of muscle mass and women by criteria muscle strength. There was good agreement between two diagnostic criteria using DEXA, and moderate to weak for others. Anthropometric measurements of the circumference of the calf (CP), midlearm circumference (MAMC) and brachial circumference (CB) have been proposed for screenig sarcopenia and all showed good sensitivity and specificity for the cutoff of DEXA, and the CP had the best performance. We conclude that there are different methods and criteria for diagnosis of sarcopenia and its aplicabillity both in elderly sample of Goiânia, as other results in different prevalence rates by sex and age. The only good agreement between the two methods indicates DEXA both the need for an operational definition and the need for early detection. Anthropometric measurements of CP, CMB and CB can be used for tracking and consequent prevention of adverse events in elderly health resulting from sarcopenia / O objetivo deste estudo foi revisar os métodos e critérios diagnósticos de sarcopenia disponíveis na literatura, estimar a prevalência e a concordância entre estes diferentes critérios em amostra de idosos de Goiânia e propor o método antropométrico como rastreamento da sarcopenia. Para revisão de métodos foram utilizadas as recomendações para comunicação de estudos de revisão sistemática e metanálise do Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement. Para os demais objetivos utilizou-se subamostra de 132 idosos do Projeto Idosos/ Goiânia, selecionados de forma proporcional aos Distritos Sanitários de Goiânia. Os dados foram coletados por equipe previamente treinada e padronizada. A sarcopenia foi analisada segundo a massa e força muscular. A massa mucular foi estimada por meio da Absortometria por raio-X de dupla energia (DEXA), bioimpedância elétrica (BIA) e antropometria; e a força muscular por meio da Força de Preensão Palmar (FPP). As análises foram realizadas no STATA 12.0, por meio de testes para comparação de médias e proporções, estimativa da prevalência e razão de prevalência, teste Kappa, cálculo de sensibilidade e especificidade e análise de Curva Roc (receiver operator characteristic curve). O projeto foi aprovado pelo Comitê de Ética em Pesquisa da Universidade Federal de Goiás. Em 28 estudos de prevalência revisados, foram encontrados 3 métodos para diagnóstico de sarcopenia: DEXA, BIA e antropometria, com variações significantes na prevalência conforme o sexo e o método adotado. Aplicando os critérios diagnósticos encontrados na subamostra do Projeto Idosos/ Goiânia, a prevalência de sarcopenia variou de 60,6% a 8,3% para os critérios de massa muscular e de 54,2% a 48,8% para os de força, aumentando nas faixa etária, sendo mais prevalente em homens por critérios de massa muscular e em mulheres por critérios de força muscular. Observou-se boa concordância entre dois critérios diagnósticos utilizando DEXA, e moderada a fraca para os demais. As medidas antropométricas da Circunferência da Panturrilha (CP), Circunferência Muscular do Braço (CMB) e Circunferência Braquial (CB) foram propostas para rastreamento de sarcopenia e todas apresentaram boa sensibilidade e especificidade para os pontos de corte de DEXA, sendo que a CP teve o melhor desempenho. Conclui-se que existem diferentes métodos e critérios para diagnóstico da sarcopenia e a aplicabilidiade deles tanto na amostra de idosos de Goiânia, como em outras resulta em diferentes prevalências conforme sexo e faixa etária. A boa concordância entre apenas dois métodos de avaliação pela DEXA sinaliza tanto a necessidade de uma definição operacional como a necessidade de detecção precoce. As medidas antropométricas da CP, CMB e CB podem ser utilizadas para rastreamento e consequente prevenção de eventos adversos a saúde do idoso decorrente da sarcopenia.
9

Avaliação da confiabilidade e concordância de métodos de avaliação da composição corporal em mulheres no período reprodutivo / Evaluation of reliability and consistency of body composition assessment methods in women in reproductive period

Rafael Costa Silva 12 January 2016 (has links)
Objetivos: Avaliar a composição corporal através da medida das dobras cutâneas (DC) intra e inter observador em mulheres na fase reprodutiva. Estimar a confiabilidade de dois protocolos de medidas de dobras cutâneas com o método Absorciometria Radiológica de Dupla Energia (DEXA). Métodos: A amostra foi composta por 90 mulheres com faixa etária de 18 a 37 anos, com Índice de Massa Corporal entre 18 e <= 39,9 Kg/m². A reprodutibilidade dos métodos foram avaliados pelos coeficientes de correlação de concordância (CCC) e coeficiente de Saint Laurent e pelos limites de concordância e gráficos de Bland-Altman. Resultados: A comparação intra observador foi excelente (CCC = 0,99) para os valores das medidas de DC tricipital, supraíliaca, coxa, soma das dobras e percentual de gordura. O mesmo ocorreu na comparação inter observador (CCC = 0,99). As medidas das DC tricipital foram as que apresentaram maior CCC (0,98), seguido da medida da coxa (0,90), e a medida da DC da suprailíaca foi a menor (0,89). A soma das DC e o percentual de gordura tiveram valores de 0,95. Já os protocolos de medidas de DC comparados entre si e com o padrão ouro DEXA, obtiveram valores de concordância baixa (0,35). Conclusões: Nossos achados mostraram que a comparação intra e inter observador foi satisfatória, contribuindo para a reprodutibilidade das medidas de DC. Os protocolos de avaliação das DC não tiveram concordância quando comparados com a DEXA / Objectives: Assessing body composition by measuring the intra and inter observer skin folds in women in the reproductive phase and estimate the reliability of two protocols skinfold measures with radiographic absorptiometry method of dual energy absorptiometry (DEXA). Methods: The sample consisted of 170 women aged 18-37 years with body mass index between 18 and <= 39.9 kg / m². The reproducibility of methods and skinfold thickness were evaluated by the coefficient of concordance correlation (CCC) and coefficient of Saint Laurent and the limits of agreement and Bland-Altman. Results: Comparison intra observer was excellent with the same values of the CCC (0.99) for the measurements of skinfold thickness of the triceps, suprailiac, thigh and fat percentage. The same occurred in the comparison inter observer (CCC = 0.99). The measures of skinfold thickness of the triceps showed the greatest CCC (0.98), followed by thigh (0.90), and the suprailiac was the lowest (0.89). The sum of the measurements of skinfold thickness and the percentage of fat had CCC values of 0.95. Already the reliability of two protocols skinfold thickness measures compared with the gold standard DEXA method was low (CCC = 0.35). Conclusions: Our findings showed that compared intra and inter observer was satisfactory, contributing to the reproducibility of skin folds. Assessment protocols skinfold did not have agreement when compared with DEXA
10

Simulação Monte Carlo do processo de aquisição de imagens de um tomógrafo de dupla energia / Monte Carlo Simulation of the Image Acquisition process of a Dual Energy Computed Tomography Device

Puerto, Lorena Paola Robayo 10 May 2018 (has links)
A Tomografia Computadorizada de Energia Dupla (DECT em inglês) é um dos campos das imagens tomográficas que mais evoluiu nos últimos anos. O DECT usa dois espectros para irradiar pacientes e é capaz de diferenciar tecidos com base na sua composição elementar. Apesar de serem semelhantes aos dispositivos padrão de tomografia, para essa modalidade é necessário o desenvolvimento de ferramentas específicas que permitam o estudo de suas propriedades de imagem. O objetivo deste trabalho era construir um sistema simulado de Tomografia Computadorizada (TC) com a capacidade de produzir imagens semelhantes às obtidas em dispositivos DECT reais. O TC simulado também permitiria explorar as propriedades das imagens de materiais de teste antes de sua construção física. Este trabalho presenta a simulação do processo de aquisição de imagens de um dispositivo DECT que funciona a partir da troca rápida de kV, o GE Discovery CT 750 HD. A geometria simulada foi baseada num dispositivo atualmente disponível no InRad (Instituto de Radiologia da Faculdade de Medicina da Universidade de São Paulo). As simulações foram realizadas usando o código Monte Carlo PENELOPE/penEasy para simular o transporte de radiação através dos materiais e detectores. Também é apresentada uma comparação entre as imagens obtidas no dispositivo real e nas simulações. Para isso, foi preparado um objeto simulador cilíndrico contendo concentrações de materiais equivalentes a iodo e cálcio. As imagens de tal objeto simulador foram adquiridas no equipamento GE Discovery CT 750 HD. Um objeto simulador equivalente foi modelado e as suas imagens foram simuladas com o código PENELOPE/penEasy. As imagens foram adquiridas e reconstruídas de acordo com as possibilidades do equipamento clínico de tomografia. Imagens de concentração de material e imagens monoenergéticas foram obtidas a partir do dispositivo CT clínico e das simulações. O algoritmo BMD (Basis Material Decomposition em Inglês) baseado nas projeções foi implementado usando os coeficientes de atenuação mássicos da água e do iodo. Consequentemente, imagens de concentração dos materiais água e iodo foram obtidas. A concentração medida nos cilindros de iodo foi equivalente às esperadas tanto no dispositivo real quanto nas imagens simuladas. Foram observados artefatos de endurecimento de feixe nas imagens de concentração de material. Imagens monoenergéticas foram obtidas para diferentes energias. Tais imagens foram obtidas a partir da superposição das imagens de concentração de água e iodo, que foram ponderadas pelos seus respectivos coeficientes de atenuação mássicos. Verificou-se que para as imagens monoenergéticas simuladas e reais em altas energias a imagem de concentração da água é a componente dominante, produzindo imagens que apresentaram as cavidades de iodo como menos atenuantes do que a água. Por outro lado, para energias baixas, a componente dominante nas imagens monoenergéticas foi a imagem de concentração do iodo. O CNR foi analisado nas imagens monoenergéticas como função da energia. As curvas do CNR dos dispositivos simulado e real exibiram semelhanças em sua forma, mas com escala diferente devido à diferença no ruído. Foi possível concluir que o modelo DECT simulado apresenta resultados qualitativos semelhantes aos obtidos no dispositivo real. O sistema de TC simulado permite explorar as características das imagens com diferentes materiais e composições. Ele também pode ser usado como uma ferramenta didática para melhorar a compreensão da diferenciação de materiais em tomografia espectral e DECT. / Dual Energy (DE) Computed Tomography (CT) is one of the fields of tomographic images that has evolved rapidly during the last years. DECT uses two X-ray spectra to irradiate patients It is capable to differentiate materials based on its elementary composition. Despite being similar to standard CT devices, DECT devices require the development of specific tools that allow the study of their image properties. The objective of this work was to build a modelled CT system capable of producing images similar to those obtained in real DECT devices. The modelled CT would also allow exploring the image properties of test materials before their physical construction. This work presents the simulation of the acquisition process of a DECT device that works with rapid kV switching, the GE Discovery CT 750 HD. The simulated geometry was based on a device currently available at the InRad (Institute of Radiology of the Faculty of Medicine of the University of São Paulo). The simulations were carried out using the PENELOPE/penEasy Monte Carlo code, which simulates radiation transport through the materials and detectors. A comparison between the images obtained in the real device and from simulations is also presented. To do so, a real phantom was prepared to be imaged and an equivalent system was simulated. The phantom contained inserts with concentrations of iodine and calcium. The images were acquired and reconstructed according to the possibilities of the real CT device. Standard, material concentration and virtual monoenergetic images were acquired[L1] from both, the real CT device and simulations. The Projection-Based BMD method was implemented using the mass attenuation coefficients of water and iodine. Then, material concentration images of water and iodine were obtained. The iodine concentrations estimated from the images agreed with the expected values in both real device and simulated images. Beam hardening artefacts were observed in the simulated material concentration images. Monoenergetic images were obtained for different energies. Such images were obtained as a superposition of the concentration images of water and iodine, weighed by their respective mass attenuation coefficient. It was verified that in the simulated and real device images, at high energies, the water concentration image predominated in the monoenergetic images, producing images that presented the iodine cavities as less attenuating than water. In contrast, at low energies, the predominant component of the monoenergetic images was the iodine concentration image. Contrast Noise Ratio (CNR) was analysed in the monochromatic images as a function of energy. Simulated and real device CNR curves exhibited similarities in their shape but with a different scale due to their difference in noise. It was possible to conclude that the simulated DECT model presented qualitative results similar to the obtained in the real device. The modelled CT system permits exploring the image features with different materials and compositions. It could also be used as a didactic tool to improve the understanding of material differentiation in spectral or DECT.

Page generated in 0.0621 seconds