• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 422
  • 188
  • 38
  • 14
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • 8
  • 6
  • 5
  • 4
  • 3
  • Tagged with
  • 777
  • 520
  • 422
  • 258
  • 187
  • 127
  • 99
  • 97
  • 86
  • 80
  • 78
  • 66
  • 65
  • 61
  • 59
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Erosive cola-based drinks affect the bonding to enamel surface: an in vitro study

Casas-Apayco, Leslie, Dreibi, Vanessa Manzini, Hipólito, Ana Carolina, Graeff, Márcia Sirlene Zardin, Rios, Daniela, Magalhaes, Ana Carolina, Buzalaf, Marília Afonso Rabelo, Wang, Linda 04 August 2014 (has links)
Objective: This study aimed to assess the impact of in vitro erosion provoked by different cola-based drinks (Coke types), associated or not with toothbrushing, to bonding to enamel. Material and methods: Forty-six bovine enamel specimens were prepared and randomly assigned into seven groups (N=8): C- Control (neither eroded nor abraded), ERO-RC: 3x/1-minute immersion in Regular Coke (RC), ERO-LC: 3x/1-minute immersion in Light Coke (LC), ERO-ZC: 3x/1-minute immersion in Zero Coke (ZC) and three other eroded groups, subsequently abraded for 1-minute toothbrushing (EROAB-RC, EROAB-LC and EROAB-ZC, respectively). After challenges, they were stored overnight in artificial saliva for a total of 24 hours and restored with Adper Single Bond 2/Filtek Z350. Buildup coronal surfaces were cut in 1 mm2-specimens and subjected to a microtensile test. Data were statistically analyzed by two-way ANOVA/Bonferroni tests (a=0.05). Failure modes were assessed by optical microscopy (X40). The Interface of the restorations were observed using Confocal Laser Scanning Microscopy (CLSM). Results: All tested cola-based drinks significantly reduced the bond strength, which was also observed in the analyses of interfaces. Toothbrushing did not have any impact on the bond strength. CLSM showed that except for Zero Coke, all eroded specimens resulted in irregular hybrid layer formation. Conclusions: All cola-based drinks reduced the bond strength. Different patterns of hybrid layers were obtained revealing their impact, except for ZC. / This study was supported in part by grants given by the São Paulo Research Foundation (FAPESP), Process no. 2009/14986-0, and the National Council for Scientific and Technological Development (CNPq), Process no. 480038/2007-4. In Addition, this study was performed by V.D.M. and A.C.H. as fulfillment of their graduation research, which was supported by FAPESP (Processes no. 2009/01376-9 and 2009/01377-5, respectively). The authors are also grateful to Oral B and SDI, which donated the materials used in the study. / Revisión por pares
162

Influence of Erosive and Abrasive Cycling on Bonding of Diferent Adhesive Systems Enamel: An in situ study

Ciccone Giacomini,Marina, Casas-Apayco, Leslie, Moreira Machado,Camila, Carvalho de Almendra Freitas,Maria Cristina, Atta,Maria Teresa, Wang, Linda January 1900 (has links)
This study evaluated the impact of orange juice on the bond strength (BS) of dentin bonding systems (DBSs) to enamel surface after simulation with an in situ/ ex vivo erosive cycling. One hundred and ninety two bovine enamel fragments (4x4x2 mm) were obtained and randomized regarding superficial microhardness and distributed to palatal devices for 8 volunteers, in three phases (one for each DBS), containing 8 blocks, which were, allocated in 4 pairs. Daily, these pairs were subjected extraorally to the following conditions: CONTneither erosive nor abrasive challenge; ERO- erosive challenge only; ABR- abrasive challenge only and ERO + ABR- with erosive and abrasive challenges. Erosive cycles (immersion in orange juice, 3 times/day/5 min/5 days) or/and abrasive challenges (electric toothbrush, 3 times/day/1 min/5 days) were performed. After these cycles, all specimens were restored with the adhesive systems Adper Scotchbond Multi Purpose (MP), Adper Single Bond 2 (SB) or Clearfil SE Bond (SE), and the composite resin Filtek Z250. After 7 days, sticks (area ≅1 mm2) were obtained and subjected to the microtensile bond strength test (μTBS) at 0.5 mm/min. Data was statistically analyzed by ANOVA and Tukey tests (a=0.05). Failure modes were determined using a digital microscope (40×). DBS was the only statistical significant factor. SE was the unique DBS not affected in any challenge, whereas MP and SB performed according to the scenario. The adhesive and mixed failures were predominant in all groups. Overall performance suggested that BS to enamel after erosive /abrasive challenged by orange juice was not affected and it was material-dependent
163

Resistência de união entre uma cerâmica e o esmalte de dente bovino, efetuada por diferentes sistemas adesivos e técnicas de cimentação / Bond strength between a ceramic and bovine tooth enamel, made by different adhesive systems and luting techniques

Sá, André Tomazini Gomes de 11 October 2011 (has links)
O objetivo no presente trabalho foi avaliar a resistência da união adesiva de uma cerâmica vítrea (IPS e.max Press) fixada sobre o esmalte de dentes bovinos. Empregaram-se dois métodos de cimentação um, com a fotoativação prévia do adesivo; outro, com a fotoativação simultânea do adesivo e do cimento compósito após a fixação do disco cerâmico, que tinha 5mm de diâmetro e 2mm de espessura. Pela combinação de dois sistemas adesivos fotopolimerizáveis (Optibond FL e Single Bond 2), e de dois cimentos (Variolink II e RelyX ARC), um fotopolimerizável e outro de cura dupla associados às duas técnicas de cimentação formaram-se oito condições de cimentação. As amostras foram submetidas a ensaio de cisalhamento pela técnica do fio de aço. Com base nos valores encontrados nas condições estabelecidas, após o respectivo tratamento estatístico, foi possível concluir que: a) a técnica de cimentação com fotopolimerização simultânea do adesivo com o cimento produziu índices de resistência superiores aos obtidos pela técnica de fotopolimerização prévia do adesivo; b) A combinação do adesivo Single Bond 2 com o cimento Variolink II resultou em menores valores de resistência adesiva, diante das outra três combinações de cimentos e adesivos formadas. / The aim of this study was to evaluate the strength of adhesive bonding of a glass-ceramic (IPS e.max Press) fixed on the enamel of bovine teeth. There were used two methods of cementation one in which the adhesive was pre-cured, and another in which the photopolymerization of the adhesive and composite cement was performed simultaneously after the fixing of ceramic disc, which was 5mm in diameter and 2mm thick. Through a combination of two light cured adhesive systems (Single Bond and FL Optibond 2) and two resin cements (Variolink II and RelyX ARC), one light-cured and another dual-cured associated with the two luting techniques eight conditions of cementation were formed. The samples were subjected to shear test technique. Under the established conditions, after statistical treatment of results the following conclusions could be drawn: a) the cementation technique with simultaneous curing of the adhesive with cement produced resistance rates higher than those obtained by the technique of pre-curing the adhesive; b) the combination of adhesive Single Bond 2 with cement Variolink II resulted in lower bond strength, in comparison with the other three combinations of cements and adhesives formed.
164

Monitoramento do processo de desmineralização e remineralização do esmalte dental humano durante e após o clareamento dental / Monitoring de-remineralizaton process on human enamel during and after dental bleaching

Andrade, Alessandra Pereira de 25 August 2009 (has links)
Este estudo in situ tem como proposta geral monitorar os processos de desmineralização e remineralização do esmalte dental humano durante e após o clareamento dental e como objetivos específicos: avaliar se o processo de desmineralização e remineralização do esmalte dental é influenciado pela utilização de agentes clareadores com diferentes composições e estimar o período necessário para que o esmalte dental clareado atinja os níveis de mineralização evidenciados anteriormente ao início do tratamento clareador. Dez voluntários participaram deste estudo utilizando dispositivos intra-orais contendo quatro fragmentos de esmalte dental humano cada que foram submetidos aos seguintes tratamentos: G1 - peróxido de hidrogênio 35% (Pola Office, SDI); G2 - peróxido de hidrogênio 7,5% (Pola Day, SDI); G3 - peróxido de hidrogênio 7,5% (Day White ACP, Discus Dental); G4 - ácido fosfórico 35% (Condicionador de ácido fosfórico 3M ESPE Scotchbond 3M ESPE). O período do estudo compreendeu 21 dias entre tratamento e monitoramento que foi realizado pelo método de fluorescência do tecido dental com o auxílio do equipamento QLF System. A análise estatística realizada pelo teste estatístico de ANOVA 2 fatores para mensurações repetidas e o teste de Tukey revelou haver diferenças estatísticas entre os tratamentos realizados e entre os tempos de mensuração. Após a realização do monitoramento do conteúdo mineral do esmalte dental durante e posteriormente ao término do tratamento clareador pode-se constatar que os agentes clareadores que apresentam composições químicas distintas ocasionaram diferentes níveis de desmineralização no esmalte dental humano, sendo que o composto ACP presente em um dos géis clareadores utilizados foi capaz de reduzir o processo de desmineralização durante o período de tratamento clareador. O período necessário para que o esmalte dental clareado atingisse os níveis de mineralização iniciais variaram em função do clareador utilizado, porém apenas o agente clareador que contém o composto ACP foi capaz de remineralizar completamente após 21 dias. / The overall proposal of this in situ study is to monitor the demineralization and remineralization process of human enamel during and after dental bleaching and its specific objectives are: to assess whether the process of demineralization and remineralization of enamel is influenced by the use of bleaching agents with different composition and estimate the time required to bleached enamel reaches the levels of mineralization observed prior to bleaching treatment. Ten volunteers participated of this study wearing intraoral devices containing four fragments of human enamel submitted to the following treatments: G1 - 35% hydrogen peroxide (Pola Office, SDI), G2 - 7.5% hydrogen peroxide (Pola Day, SDI); G3 - 7.5% hydrogen peroxide (Day White ACP, Discus Dental); G4 - 35% phosphoric acid (Scotchbond 3M ESPE, 3M ESPE). The study period comprised 21 days of treatment and monitoring. Monitoring was conducted by the quantitative light fluorescence method, with QLF System. Statistical analysis performed by the statistical two-way ANOVA for repeated measurements and Tukey tests demonstrated differences between treatments and between measurement times. Monitoring the enamel mineral content during and after the end of the bleaching treatment revealed that the bleaching agents with different chemical compositions resulted in different levels of human enamel demineralization and that, the ACP compound present in one of the bleaching agents used was able to reduce the demineralization process during the bleaching treatment. Time required for the bleaching human enamel reaches the initial levels of mineralization varied depending on the bleaching agent used, but only the bleaching agent containing ACP was able to completely remineralize enamel after 21 days.
165

"Efeito de tratamentos de limpeza na resistência adesiva de sistemas autocondicionantes ao esmalte dental íntegro e em contato com saliva humana" / Cleaning treatment effects on self-etching adhesive bonding strength to unground dental enamel after salivary contact

Vega, Ana Del Carmen Armas 13 September 2005 (has links)
Esta pesquisa avaliou o efeito de diferentes técnicas de limpeza aplicadas na superfície de esmalte intacto, na resistência adesiva de resina composta usando sistemas adesivos self etch. Coroas dentais foram cortadas e obtidos 90 fragmentos (n=10), cujas superfícies de esmalte permaneceram em contacto com saliva humana fresca por 1 hora, recebendo a seguir de acordo com o grupo, limpeza com uma das seguintes técnicas: pasta de pedra pomes/água seguida de detergente aniônico Tergensol (PP), jato de bicarbonato de sódio (B), ou spray ar/água (C). Após limpeza, um dos sistemas adesivos foi aplicado: Clearfil SE Bond (CF), Adper Prompt (AD) ou Scotchbond Multi-Purpose (SB), realizando-se um bloco de resina composta Z250 de 4 ou 5 mm sobre o adhesivo dental. Após 24 horas de armazenagem, os corpos de prova foram cortados em maquina Labcut, originando palitos com área adesiva de aproximadamente 1 mm 2 . Cada palito foi adaptado em um dispositivo de tração, para serem realizados os testes de resistência adesiva. A análise estadística, considerando a cada palito como unidade amostral, e os tipos de fraturas apresentadas, mostrou ausência de diferença entre os sistemas adesivos usados. Entre as técnicas de limpeza testadas, valores de RMT foram superiores para a técnica de PP, não se encontrando diferenças estatisticamente significantes entre B e C. A análise ao MEV da interface esmalte/resina confirmou os resultados estatísticos encontrados e permitiu observar que a interação resina adhesiva/esmalte ocorre de maneira diferente entre os sistemas self etch e all etch. Concluiu-se que, a técnica PP constitui uma opção adequada de limpeza de superfícies de esmalte liso intacto e que a técnica de bicarbonato pode afetar a resistência adesiva destas superfícies. / This study evaluated the effect of different cleaning techniques in the adhesive bond strength of self-etching bonding systems to unground enamel after being in contact with human saliva. Ninety enamel fragments were obtained from dental crowns (n = 10) and the enamel surface of each fragment were kept in contact with fresh human saliva for 1 hour. Next, they received the cleaning treatment according to the group as follows: pumice and water paste followed by anionic detergent - Tergensol (PP), sodium bicarbonate jet (B), or air/water spray (control group - C). After cleaning procedures, one of the bonding systems was applied: Clearfil SE Bond (CF), Adper Prompt (AD), or Scothbond Multi-Purpose (SB), and a Z250 composite resin bloc with 4 or 5 mm was built above the dental adhesive. After 24 hours of storage, the specimens were sectioned to obtain sticks with cross sectional areas of approximately 1 mm². The sticks were submitted to microtensile test in an Instron testing machine. Statistical analysis of the results, considering each stick as a sample unit and the fracture kinds presented, showed no statistical significant difference in mean shear bond strength among the bonding systems used. Regarding to the cleaning techniques, shear bond strength values were superior for PP and there was no significant statistical difference between B and C. The interface enamel/dentin SEM analysis corroborated the statistical results I was concluded that PP method is appropriate for cleaning unground enamel surface after salivary contact, improving bond strength of all etch and self etch adhesive systems, and that cleaning with sodium bicarbonate jet may affect the bonding strength of these surfaces.
166

Efeito da utilização prévia de agentes dessensibilizantes na resistência de união de sistemas adesivos à dentina humana / Efect of desensitizing agents on the bond strength of adhesive systems to human dentin

Chermont, Armando Brito 30 April 2013 (has links)
O objetivo deste estudo foi avaliar o efeito de agentes dessensibilizantes na resistência de união de diferentes sistemas adesivos condicione e lave e autocondicionantes a dentina humana por meio do microcisalhamento. Foram utilizados sessenta fragmentos de dentina obtidos das superfícies vestibular e lingual de terceiros molares inclusos, que foram distribuídos em grupos (n-12) de acordo com o tratamento dessensibilizante (controle - sem tratamento; oxalato de potássio; CPP-ACP + flúor; arginina; nanohidroxiapatita) e os sistemas adesivos (Adpter Single Bond 2 / 3M; Clearfil SE Bond / Curaray) empregados. As aplicações de agentes dessensibilizantes (2 ml) foram realizadas em três sessões com intervalo de 48 horas. Os fragmentos de dentina permaneceram imersos em 6 ml de saliva artificial no período entre as aplicações. Os sistemas adesivos foram aplicados conforme as orientações dos fabricantes e fotopolimerizados por 40 segundos. Sobre cada superfície dentinária foram confeccionados dois cilindros em resina composta. O ensaio mecânico de microcisalhamento foi realizado usando uma velocidade de 1 mm/min.Os padrões de fratura foram determinados por meio de um microscópio digital com aumento de 50 vezes . As fraturas foram classificadas como adesivas, coesivas em dentina, coesivas em resina e mistas descritas percentualmente pelos testes ANOVA 2-way e o teste Bonferroni (p<0.05) . Concluiu-se que os tratamentos dessensibilizantes influenciaram na resistência de união dos sistemas adesivos condicione e lave; o tratamento com oxalato de potássio e arginina reduziu a resistência de união dos autocondicionantes; o tratamento com CPP-ACP e com a nanohidroxiapatita não interferiram na adesão dos autocondicionantes. / The aim of this study was to evaluate the effect of desensitizing agents on the bond strength of different adhesive systems condition and rinse and self-etching to dentin through microshear. Were used sixty dentin fragments obtained from the buccal and lingual surfaces of molars third molars, which were distributed in groups (n = 12) according to desensitizing treatment (control - no treatment; potassium oxalate; + CPP-ACP fluorine; arginine; nanohidroxiapatita) and adhesive system (Single Bond Adpter 2 / 3M; Clearfil SE Bond / Curaray) employee. The application of desensitizing agents (2 ml) were performed in three sessions with an interval of 48 hours. The dentin fragments remained immersed in 6 ml of artificial saliva in the period between applications. The adhesive systems were applied according to the instructions of the manufacturer and cured for 40 seconds. About every two dentin surfaces were fabricated in composite cylinders. The mechanical test was performed using a microshear speed of 1 mm / min .The fracture patterns were determined using a digital microscope with increased 50 times. Fractures were classified as adhesive, cohesive in dentin and composite resin cohesive described percentage. 2-way ANOVA and the Bonferroni test (p <0.05) It was concluded that the desensitizing treatments influenced the bond strength of adhesive systems and conditional wash; treatment with potassium oxalate and arginine reduced the bond strength of self-etching; treatment with CPP-ACP did not interfere with hydroxyapatite and adhesion of self-etching .
167

Estudos dosimétricos de tecidos duros e alimentos por ressonância paramagnética eletrônica / Dosimetric studies Food and Hard Tissues using Electron Paramagnetic Resonance.

Leonor, Sérgio Jacintho 23 March 2012 (has links)
Este trabalho consiste no estudo e nas aplicações da dosimetria por Ressonância Paramagnética Eletrônico (RPE). Em uma tentativa de realizar a dosimetria retrospectiva do esmalte dentário através do menor método invasivo possível utilizamos espectrômetros de Ressonância Paramagnética Eletrônico (RPE), operando em Banda - X e Banda - K, visando determinar as condições que poderiam ser usados em casos de exposições acidentais. Primeiro, um pequeno prisma de esmalte foi removido e um almofariz de ágata foi utilizado para triturar este prisma até que as partículas atinjam um diâmetro de cerca de 0,5 mm. Este processo de extração do esmalte resultou em um menor sinal de artefato comparado com a extração de esmalte realizado diretamente com uma broca de abrasão diamantada. A moagem manual do esmalte não leva a qualquer sinal induzido de RPE, enquanto que o uso de uma broca diamantada mesmo em baixa velocidade aparecem rebarbas produzindo um sinal de artefato equivalente ao sinal dosimétrico induzido por uma dose de 500 mGy de radiação gama. Uma massa de 25 mg de esmalte foi removida de um dente molar previamente irradiado in vitro com uma dose de 100 mGy. Esta quantidade de esmalte foi suficiente para detectar o sinal dosimétrico em um espectrômetro de Banda - X padrão. Utilizando a Ressonância Paramagnética Eletrônica (RPE) espectros de goma arábica irradiados com doses entre 0,5 e 5 kGy foram estudados. A relação linear entre a dose absorvida e as intensidades dos espectros de RPE foi observada. Espectros de RPE irradiados de goma arábica apresentaram um decaimento das concentrações relativas dos radicais livres originados pela radiação produzindo pelo menos duas espécies de radicais livres com meia-vida de 3,3 e 125,4 horas. Os resultados das simulações encontradas para estes grupos radicais foram giso = 2,0046; A = 1,2 mT e gx = gy = 2,0062, gz = 2,0025. / In an attempt to make in vitro electron spin resonance (ESR) retrospective dosimetry of the tooth enamel a lesser invasive method, experiments using X-Band and K-Band were performed, aiming to determine conditions that could be used in cases of accidental exposures. First, a small prism from the enamel was removed and ground with an agate mortar and pestle until particles reach a diameter of approximately less than 0.5 mm. This enamel extraction process resulted in lower signal artifact compared with the direct enamel extraction performed with a diamond burr abrasion. The manual grinding of the enamel does not lead to any induced ESR signal artifact, whereas the use of a diamond burr at low speed produces a signal artifact equivalent to the dosimetric signal induced by a dose of 500 mGy of gamma irradiation. A mass of 25 mg of enamel was removed from a sound molar tooth previously irradiated in vitro with a dose of 100 mGy. This amount of enamel was enough to detect the dosimetric signal in a standard X-Band spectrometer. Electron spin resonance (ESR) spectra of irradiated gum Arabic with doses between 0.5 to 5kGy were studied. A linear relationship between the absorbed dose and the intensities of the ESR spectra was observed. ESR spectra of irradiated gum Arabic showed a decay of relative concentrations of free radicals originated by radiation and the production of at least two species of free radicals with half-times: 3.3 and 125.4 hours. The results of spectral simulations for these radical groups were giso= 2.0046; A= 1.2mT and gx= gy= 2.0062, gz= 2.0025.
168

Influência de materiais bioativos sobre a dureza, ultraestrutura e conteúdo mineral de dentes clareados: estudo in situ / Changes after whitening: bioactive materials benefits- in situ study

Pinheiro, Helena Burlamaqui 03 August 2012 (has links)
Objetivo: Investigar in situ a influência de materiais bioativos sobre a superfície do esmalte e dentina clareados, utilizando o teste de dureza Knoop (KHN), microscópio por emissão de campo (FEG) e quantificação do conteúdo mineral por fluorescência do substrato dental (QLF). Material e Métodos: Vinte molares humanos intactos foram selecionados. Para KHN e FEG, foram necessários 10 dentes. Foram obtidos 6 espécimes da porção cervical de cada dente, contendo esmalte e dentina, e distribuídos entre os 5 grupos experimentais, mais um controle (n=10). O grupo controle (sem tratamento) foi utilizado para o FEG, pois neste tipo de análise há destruição da amostra, não sendo possível a utilização de um mesmo espécime para obtenção de imagens nas fases antes e após o tratamento. Para o teste de dureza, as fatias tiveram os valores iniciais de dureza do esmalte e dentina medidos. Para o QLF, foram usados outros 10 dentes. Cada um foi seccionado em 5 fragmentos de esmalte superficial, retirados da porção coronária de cada dente. Metade de cada espécime foi protegida com verniz e a outra metade serviu para entrar em contato com os diversos tratamentos. Os fragmentos tiveram a quantificação mineral inicial medida pelo QLF. Todos os espécimes foram montados em retentores palatinos intraorais e usados por 10 voluntários durante 24h/dia, por 14 dias. Em cada dispositivo, eram aplicados os 5 diferentes tratamentos: 1: Opal, tratamento clareador com peróxido de carbamida (PC) 15% - Opalescence PF, Ultradent; 2: NiteWhite ACP, PC16% (Philips); 3: Opal + Bio (Biosilicato®, Vitrovita) misturados; 4: Opal Bio (Biosilicato® aplicado por 5 min, 1 vez por semana após clareamento); 5: Opal Rel ACP, Relief ACP (Philips) aplicado por 30 min por dia após clareamento. Em seguida, foram realizadas análises finais de KHN, FEG e QLF. Resultados: A análise estatística revelou que no grupo Opal houve redução significante dos valores de dureza em esmalte. No grupo Opal Bio, a aplicação do material bioativo não foi capaz de evitar a desmineralização do esmalte. Para os demais grupos, não houve alteração dos valores de dureza. Na dentina, o grupo Opal também causou diminuição na dureza. Nos grupos Opal Bio e Opal Rel ACP, a aplicação dos dois materiais bioativos não foi suficiente para evitar diminuição dos valores de dureza em dentina. Já nos grupos NW ACP e Opal + Bio, não foi observada desmineralização desse substrato. Os dados de dureza refletem os resultados observados na análise ultraestrutural do esmalte e da dentina, em que os grupos NW ACP e Opal + Bio apresentaram os melhores desempenhos em relação aos demais grupos. A análise por QLF não apresentou sensibilidade para detectar diferenças estatisticamente significantes entre os grupos e nem entre as fases inicial e final em nenhum dos grupos. Conclusão: No grupo Opal, observa-se desmineralização do esmalte e dentina clareados. A aplicação de Biosilicato® 1x por semana não foi suficiente para evitar alterações em esmalte e dentina. Relief ACP, aplicado diariamente após o tratamento clareador, foi capaz de evitar alterações em esmalte, mas não em dentina. A mistura de um gel clareador com um agente bioativo, como acontece nos grupos NW ACP e Opal + Bio, teve influência positiva em relação à dureza e morfologia da estrutura dental evitando sua desmineralização; nesses dois grupos, foram observados os melhores resultados tanto de dureza, quanto na análise ultraestrutural. / Objective: To Investigate in situ the influence of bioactive materials on whitened enamel and dentin surfaces using Knoop hardness test (KHN), field emission microscope (FEG) and quantitative light-induced fluorescence (QLF). Material and Methods: Twenty intact human molars were selected. Ten teeth for KHN and FEG were used. Six specimens were obtained from the cervical portion of each tooth, containing enamel and dentin. The slices were distributed into five experimental groups and one control (n=10). The control group (no treatment) was used for the FEG images, as this type of analysis destroys the sample, making it impossible to use the same specimens for before and after treatment images. For the hardness test, the enamel and dentin baseline Knoop hardness were measured for each slice for the control group and the five experimental groups. For QLF the other 10 teeth were used, each one sectioned into 5 superficial enamel slices. Half of each specimen was protected with varnish and the other half used to be in contact with the different treatments. The specimens had their baseline mineral content values measured by QLF. All specimens were mounted on intra-oral palatal retainers, which were used by 10 volunteers during 24h/day for 14 days. On each retainer five different treatments were applied: 1: Opal, whitening treatment (WT) with Opalescence PF, 15% carbamide peroxide (CP) (Ultradent); 2: NW ACP, whitening treatment with NiteWhite ACP, 16% CP (Philips); 3: Opal + Bio (Biosilicate®, Vitrovita) mixed; 4: Opal Bio (Biosilicate® applied for 5 minutes once a week after WT; 5: Opal Rel ACP, Relief ACP (Philips) applied 30 min per day after WT. Afterward, further KHN, FEG and QLF analysis were performed. Results: A statistical analyses revealed that the Opal group had a significant enamel hardness decrease. In the Opal Bio group, the application of the bioactive material was not able to prevent enamel demineralization. For the other groups changes in the hardness values were not observed. The Opal group also caused hardness decrease in the dentin. In the Opal Bio and Opal Rel ACP groups the application of the two bioactive materials was not enough to prevent the dentin hardness decrease. In the NW ACP and Opal + Bio groups demineralization of the substrate was not observed. The hardness data reflect the results observed in the ultra structural analysis of enamel and dentin, which groups NW ACP and Opal + Bio showed better performance compared to other groups. The QLF analysis was not sensitive enough to detect statistically significant differences between groups or between the initial and final phases in either groups. Conclusion: Enamel and dentin demineralization was observed for the Opal group. The application of Biosilicato® once a week was not enough to prevent enamel and dentin alterations. Relief ACP, applied daily after the whitening treatment, prevented changes in enamel but not in the dentin samples. The bioactive materials, when incorporated in the whitening gel (NW ACP and Opal + Bio groups), deliver positive benefits for tooth hardness and morphology, preventing demineralization; in both groups better hardness and morphology results were observed.
169

Desenvolvimento e avaliação de resina composta odontológica com esmalte bovino como partícula de carga / Development and evaluation of a dental composite resin using bovine enamel as reinforcing filler

Tribioli, Jeison Tallis 22 February 2011 (has links)
A utilização de resinas compostas para restaurações em dentes anteriores e posteriores é bastante frequente na odontologia atual, pois suas propriedades mecânicas e estéticas são compatíveis a estrutura dental. O objetivo deste trabalho foi confeccionar e caracterizar uma resina composta para uso odontológico utilizando esmalte bovino como carga de reforço. Para confeccionar a resina composta a mesma matriz orgânica comumente utilizada nas resinas comerciais foi empregada. A carga de reforço foi obtida através da moagem de fragmentos de esmalte bovino, e posteriormente submetida a um tratamento superficial para que tornasse possível a união das partículas com a matriz orgânica. Foram confeccionadas resinas compostas nas concentrações de 60, 70 e 85% em peso de carga. Para fotopolimerização um dispositivo a base de LED com banda de emissão centrada em 470 nm com intensidade e 1000 mW/cm2 foi usado. Duas resinas comerciais Filtek Z-250 e Supreme XT (3M ESPE) ambas na cor A2 foram empregadas para comparação. A caracterização das resinas experimentais e comerciais foi realizada através de ensaios de compressão axial e diametral, grau de conversão, teste de dureza Vickers e fluorescência. No teste de fluorescência realizado em dentes humanos, a resina experimental com 85% de partícula de carga em peso apresentou valores de intensidade de fluorescência em escala de cinza ao redor de 34 (unid. arb.) sendo mais semelhante ao dente (41 unid. arb.) quando comparada com as resinas comerciais que obtiveram valores ao redor de 17 (unid. arb.). Baseado nos testes realizados, a resina experimental apresenta propriedades promissoras para utilização em restaurações. / The use of composite resins for restorative procedure at anterior and posterior cavities is highly common in the modern Dentistry because its mechanical and aesthetic properties are compatible with the remanescent dental structure. The aim of this study was the manipulation and characterization of a dental composite resin using bovine enamel as reinforcing filler. The same organic matrix of the commercially available resins was used for this experimental resin. The reinforcing filler was obtained after the gridding of bovine enamel fragments and a superficial treatment was performed to allow the adhesion of the filler particles with the organic matrix. The experimental resin was manipulated at the weight filler concentrations of 60%, 70%, and 85%. A LED-based light source with 1000 mW/cm2 centered at 470 nm was used for photopolimerization. Two commercial resins, Filtek Z-250 and Supreme XT at A2 shade, were used for comparison. The resin characterization was performed with tensile strength and diametral tensile strength tests, conversion degree, Vickers hardness, and fluorescence. In the fluorescent test performed at human teeth, the experimental resin with 85% particle weight showed fluorescence intensity values at gray scale, around 34 (arbitrary units), being more similar to the tooth (41 arb. units) when compared with commercial resins (17 arb. units). Based on the investigated tests, the present experimental resin shows promising properties to its use on dental restorations.
170

Desenvolvimento de uma interface de comunicação para determinação da difusividade térmica em função da temperatura, por termografia no infravermelho / Development of a communication interface to determinate the thermal diffusivity as a function of temperature by infrared thermography

Corrêa, Paulo Roberto 21 March 2013 (has links)
O objetivo deste trabalho foi desenvolver um software, de fácil operação e eficiente, para determinar a difusividade térmica de biomateriais. A necessidade de se conhecer a difusividade térmica de materiais como, por exemplo, esmalte e dentina, é essencial para o estabelecimento de protocolos de utilização clínica laser, para evitar danos colaterais ao paciente. O software desenvolvido, denominado CZ ThermaDiff, baseia-se no processamento de imagens térmicas adquiridas por uma câmera termográfica no infravermelho (ThermaCam SC3000, FLIR System, EUA). Foi desenvolvido em ambiente LabView, o que permitiu criar um painel de controle de fácil operação, contendo apenas duas funções básicas (Start e Stop). O software arquiva os dados em formato de tabela contendo todas as medidas de difusividade térmica, suas médias para intervalos de 10 °C e suas respectivas temperaturas, para uma amostra. Foi observado, tanto para o esmalte quanto para a dentina, que os valores de difusividade não são constantes e aumentavam em função da temperatura. Os valores encontrados foram aplicados a um modelo de transferência de calor, simulando um dente molar humano com as seguintes estruturas: esmalte, dentina e polpa. O modelo baseia-se no método de resistores térmicos, sendo que para a polpa foi utilizado o modelo de difusão de calor, considerando a circulação sanguínea. Os valores de temperatura obtidos neste modelo teórico, utilizando difusividades dependentes da temperatura foram maiores que as obtidas com um valor constante de difusividade, medido à temperatura ambiente. Este fato realça a importância da mensuração da difusividade em função da temperatura e da interface desenvolvida neste trabalho. / The aim of this work was to develop a software, easy to operate and efficient, to determine the thermal diffusivity of biomaterials as enamel and dentin. It is necessary to know the thermal diffusivity of these materials to establish laser irradiation protocols, to avoid collateral damage to the patient. The software developed named called CZ ThermaDiff, processes thermographic images from a thermographic camera (ThermaCam SC300, FLIR System, USA). The software was programmed in LabView environment, allowing easy operation from a control window with only two buttons (start and stop). Thermal diffusivity values, the mean values for intervals of 10 °C and its respective temperature, for one sample are saved in table form. For both biomaterials, thermal diffusivity increased as function of the temperature increase. The experimental thermal diffusivity data were used in a heat transfer model, for a human molar tooth with three layers: enamel, dentin and pulp. The model was based on the thermal resistors method, for the three layers and for the pulp, it was applied the heat diffusion model, taking into account the blood circulation. Using temperature dependent diffusivities, temperatures where values were higher than the temperatures of the theoretical model using a constant diffusivity value, obtained at ambient temperature. This fact emphasized the importance of both: the temperature dependent diffusivity measurement and the software developed in this work.

Page generated in 0.0442 seconds