• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 422
  • 188
  • 38
  • 14
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • 8
  • 6
  • 5
  • 4
  • 3
  • Tagged with
  • 777
  • 520
  • 422
  • 258
  • 187
  • 127
  • 99
  • 97
  • 86
  • 80
  • 78
  • 66
  • 65
  • 61
  • 59
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Remineralization of human enamel in vivo

Gelhard, Thaddeus Bernardus Franciscus Maria. January 1982 (has links)
Thesis (doctoral)--Rijksuniversiteit te Groningen.
202

Vitamin D receptor deficiency and postnatal tooth formation

Zhang, Xueming, January 2007 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2007. / Title from first page of PDF file (viewed June 30, 2007). Includes bibliographical references (p. 98-101).
203

Resistência ao cisalhamento de diferentes sistemas adesivos no esmalte dental /

Paradella, Thaís Cachuté. January 2004 (has links)
Orientador: Marcelo Fava de Moraes / Banca: Priscila Christiane Suzy Liporoni / Banca: Rebeca Di Nicoló / Resumo: O objetivo deste estudo foi avaliar in vitro três sistemas adesivos: um monocomponente com condicionamento ácido prévio (GI Prime & Bond 2.1), um primer autocondicionante (GII Clearfil SE Bond) e um adesivo autocondicionante (GIII One Up Bond F), através da resistência ao cisalhamento no esmalte de dentes humanos, avaliando-se o tipo de fratura por estereomicroscopia. Trinta pré-molares armazenados em solução de cloramina a 0,5% receberam cortes em sentido médio-distal e tiveram suas superfícies de esmalte planificadas. Os espécimes foram aleatoriamente divididos nos três grupos experimentais (n=20). A área de atuação dos adesivos foi delimitada e os procedimentos adesivos realizados conforme recomendações dos fabricantes. Cilindros de resina composta Z-250 de 3mm de diâmetro foram confeccionados. Os espécimes foram armazenados em água destilada a 37°C por 24h, termociclados por 500 ciclos (5°C-55°C) e cisalhados com velocidade de 0,5mm/min. As médias de resistência adesiva foram Gl 18,13 ± 6,49 MPa, com 55% de fraturas coesivas em resina composta; Gll 17,12 ± 5,80 MPa com 90% de fraturas adesivas e Glll 10,47 ± 3,14 MPa com 85% de fraturas adesivas. Os dados foram submetidos à análise estatística ANOVA e comparação múltipla de Tukey (5%), não havendo diferenças significantes entre o Gl e o GIl, tendo o Glll diferença significante em relação aos outros grupos. O tipo de fratura mais predominante (adesiva do GIl) foi submetido à MEV e observou-se a ruptura na interface resina-dente. Concluiu-se que o adesivo do Gl promoveu resistência de valor semelhante ao GII, porém com tipo de fratura diferente / Abstract: The purpose of this study was to evaluate in vitro three adhesive systems: a total etch single-component (GI Prime & Bond 2.1 ), a self-etching primer (GII Clearfil SE Bond) and a self-etching adhesive (GIII One Up Bond F), through shear bond strength on enamel of human teeth, evaluating the type of fracture through stereomicroscopy. Thirty premolars, kept in 0.5% chloramines solution received cuts in mesium-distal sense and had their ena mel surfaces prepared. They were randomly assigned to three experimental groups (n=20). The adhesive system's area of acting was determined and the adhesive procedures were performed according to the manufactureis instructions. 3mm Z-250 composite resin cylinders were performed. The specimens were kept in distilled water at 370C for 24h, thermocycled for 500 cycles (5ºC-55ºC) and submitted to shear with 0.5mm/min speed. The adhesive resistance mediums were GI 18.13 ± 6.49 MPa, with 55% of resin cohesive fractures; GII 17.12 ± 5.80 MPa with 90% of adhesive fractures and GIII 10.47 ± 3.14 MPa with 85% of adhesive fractures. The data was submitted to Anova and Tukey multiple comparison (5%) statistical analysis. There were no significant differences between Gl and GIl, having GIII significant difference regarding the other groups. The predominant type of fracture (adhesive in GIl) was submitted to SEM and the rupture in the resin-tooth interface was noticeable. lt was concluded that the adhesive system in Gl presented similar shear bond strength to GIl, however with a different type of fracture / Mestre
204

Estudo radiográfico da espessura do esmalte nas faces proximais de dentes anteriores e posteriores

Amaral, Roberta Maria de Paula [UNESP] 23 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-23Bitstream added on 2014-06-13T18:09:52Z : No. of bitstreams: 1 amaral_rmp_me_arafo.pdf: 716789 bytes, checksum: 406e0b87387205de192b14b6c0012426 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A técnica de desgastes interproximais é um procedimento ortodôntico freqüente na prática ortodôntica, no qual parte do esmalte dental da área interproximal é removida, e para que este seja realizado com segurança é importante estimar a espessura de esmalte presente. Este estudo descreve a espessura do esmalte nas faces mesial e distal dos dentes permanentes anteriores e posteriores e avalia as correlações desta medida entre os dentes do arco superior e inferior, entre os dentes da região anterior e posterior e entre as faces mesial e distal. Foram selecionados 34 adultos jovens (21 mulheres e 13 homens) entre 13 a 24 anos de idade. Radiografias periapicais dos incisivos centrais, laterais e caninos e interproximais dos pré-molares e molares, superiores e inferiores do lado direito, foram digitalizadas em um scanner de mesa, para posterior mensuração da espessura do esmalte nas faces mesiais e distais, utilizando o software “Image tool”. Os dados obtidos foram avaliados estatisticamente pelos testes Kolmorov-Smirnov, t de Student e de Pearson e mostraram que os valores médios de espessura do esmalte nas faces proximais tornam-se progressivamente maiores distalmente, nos dentes posteriores o esmalte é mais espesso que nos anteriores 5,36 mm no arco inferior e 4,48mm no superior. A espessura do esmalte nas faces distais é significantemente maior que nas mesiais. A espessura total do esmalte interproximal de uma hemiarco é de 14,87 mm para os dentes superiores e 14,78 mm para os inferiores. Correlações positivas, estatisticamente significantes, foram encontradas entre as espessuras do esmalte das faces mesial e distal, dos dentes anteriores e posteriores, assim como, em grande parte dos valores obtidos para os dentes dos arcos superior e inferior. / Interproximal reduction is a frequent orthodontic procedure in clinical practice, in which part of dental enamel in the interproximal area is removed. To perform safe interproximal reduction, it is important to estimate the actual enamel thickness. This study describes the enamel thickness in mesial and distal surfaces of both anterior and posterior teeth and evaluates possible correlations between the measurements obtained from maxillary and mandibular arches, from anterior and posterior regions, as well as mesial and distal surfaces. The sample comprised 34 young adults (21 females, 13 males) 13 to 24 years old. Periapical radiographs from right central and lateral incisors and canines, and bitewing radiographs from pre-molars and molars, from maxillary and mandibular arches, were digitalized and the data required for the research were calculated in the Image tool software. The analysis of data was made using Kolmorov-Smirnov test, Student T test and Pearson Correlation Coefficient and showed that averages of enamel thickness in proximal surfaces becomes progressively thicker distally, total enamel in posterior teeth was greater than anterior 5,36 mm for mandibular arch and 4,48 mm for maxillary. Enamel thickness was consistently greater on the distal surface than on the mesial. Total enamel in proximal surfaces was 14,87 mm for maxillary teeth and 14,78 mm for mandibular teeth. Positive correlation, statistically significant, was found between the enamel thickness of the mesial and distal surfaces, anterior and posterior teeth, as well as, to a large extent of the values obtained for teeth of mandibular and maxillary arches.
205

Comparação termométrica entre preparos cavitários realizados com turbinas de alta-rotação e laser de Er:YAG /

Cavalcanti, Bruno das Neves. January 2001 (has links)
Orientador: Sigmar de Mello Rode / Banca: Fernando Ricardo Xavier da Silveira / Banca: Maria Auxiliadora Junho de Araujo / Resumo: O objetivo deste estudo foi comparar as variações de temperatura provocadas por turbinas de alta-rotação e pelo laser de Er:YAG (350mJ/10 Hz). Preparos cavitários classe V foram realizados numa profundidade de 2,0mm em 35 incisivos inferiores bovinos, que tiveram um termopar posicionado para ler as temperaturas no interior da câmara pulpar. A análise foi feita nos seguintes grupos: I - alta-rotação sem refrigeração a água; II - alta-rotação com refrigeração a água; III- laser de Er:YAG sem refrigeração a água; IV- laser de Er:YAG com refrigeração a água. Em todos os grupos foram utilizados dez dentes, com exceção do grupo III, que teve uma amostra de apenas cinco dentes, uma vez que foi impossível realizar os preparos adequadamente com o laser sem refrigeração. Os aumentos de temperatura foram gravados num computador ligados aos termopares e os dados dos grupos I, lI e IV foram submetidos ao teste de Dunn para comparações múltiplas (p<0,05). Os aumentos médios de temperatura foram: 11,64°C para o grupo I, 0,96°C para o grupo II, 40,86°C para o grupo lll e 2,9°C para o grupo IV. Não houve diferenças estatisticamente significantes entre os grupos II e IV, e estes foram diferentes do grupo I. Os preparos cavitários realizados com as turbinas de alta-rotação e com o laser de Er:YAG geraram aumentos de temperatura semelhantes quando sob refrigeração a água. A refrigeração é essencial para evitar aumentos de temperatura agressivos em ambos os casos e com o laser de Er:YAG é especialmente necessária para a ablação do esmalte / Abstract: The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel / Mestre
206

Polimorfismos em genes da resposta imune em indivíduos com Hipomineralização Molar-Incisivo (HMI) /

Bussaneli, Diego Girotto. January 2017 (has links)
Orientador: Rita de Cássia Loiola Cordeiro / Resumo: O objetivo deste estudo foi avaliar a possível associação entre a Hipomineralização Molar-Incisivo (HMI) e polimorfismos em genes da resposta imune, e sua interação com polimorfismos em genes relacionados a amelogênese. Amostras de DNA foram coletadas de 101 núcleos familiares que apresentavam pelo menos uma criança diagnosticada com HMI. Onze polimorfismos de base única (SNP) relacionados a resposta imune foram genotipados por meio de PCR em tempo real com ensaio TaqMan. A análise da associação foi realizada com o teste de desequilíbrio de transmissão (TDT), levando-se em consideração a severidade da HMI. A interação gene-gene entre os polimorfismos da resposta imune e da amelogênese foi realizada por meio da observação da transmissão dos alelos referentes aos marcadores pelos pais heterozigotos para ambos os marcadores, e o teste Qui quadrado foi utilizado a fim de determinar se ambos os alelos são transmitidos mais frequentemente em associação, do que individualmente. O nível de significância adotado foi de 5%. Resultados significantes foram obtidos para o SNP rs10733708 (gene TGFBR1, OR = 3.5, 95% IC = 1.1 - 10.6) para os casos severos de HMI. As interações gene-gene foram significativas entre o SNP rs6654939 (AMELX) com os SNPs rs2070874 (IL4), rs2275913 (IL17A), rs1800872 (IL10), rs1800587 (IL1A) e rs3771300 (STAT1). O SNP rs2070874 (IL4), quando associado com os marcadores rs7526319 (TUFT1) e rs2355767 (BMP4) também demonstrou resultados significativos, sugerindo um ef... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was evaluate the possible association between immune-related genes polymorphisms and Molar-Incisor Hypomineralization (MIH), and its interaction with amelogenesis-related genes polymorphysms. DNA samples were obtained from 101 nuclear families that had at least one MIH affected children. Eleven single nucleotide polymorphisms (SNP) were investigated in immune response candidate genes using the TaqMan method. Association analysis was performed by the transmission/disequilibrium test (TDT) considering the MIH severity. The gene-gene interaction between the immune-related and amelogennesis-related polymorphisms was performed by observing the transmission of markers alleles from parents heterozygous for both of the markers. The Qui squared test was used to determine whether both alleles are transmitted more often in association than individually. Significant result was observed for the SNP rs10733708 (TGFBR1 gene, OR = 3.5, 95% CI = 1.1 - 10.6) for severe cases of HMI. Gene-gene interactions were significant between SNPs rs6654939 (AMELX) and SNPs rs2070874 (IL4), rs2275913 (IL17A), rs1800872 (IL10), rs1800587 (IL1A) and rs3771300 (STAT1). The SNP rs2070874 (IL4) was significant when associated with SNPs rs7526319 (TUFT1) and rs2355767 (BMP4), suggesting a synergistic effect of the transmission of these alleles with susceptibility to HMI. This family-based study demonstrated an association between variation in the TGFBR1 gene and HMI. The polymorphisms in immune response and amelogenesis genes may have an additive effect on the risk of developing HMI. / Doutor
207

Comparação termométrica entre preparos cavitários realizados com turbinas de alta-rotação e laser de Er:YAG

Cavalcanti, Bruno das Neves [UNESP] 07 November 2001 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:22:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-11-07. Added 1 bitstream(s) on 2015-12-10T14:28:48Z : No. of bitstreams: 1 000143720.pdf: 2203998 bytes, checksum: 0f8fb99f8ca3fb9d8ef894f9e4063677 (MD5) / O objetivo deste estudo foi comparar as variações de temperatura provocadas por turbinas de alta-rotação e pelo laser de Er:YAG (350mJ/10 Hz). Preparos cavitários classe V foram realizados numa profundidade de 2,0mm em 35 incisivos inferiores bovinos, que tiveram um termopar posicionado para ler as temperaturas no interior da câmara pulpar. A análise foi feita nos seguintes grupos: I - alta-rotação sem refrigeração a água; II - alta-rotação com refrigeração a água; III- laser de Er:YAG sem refrigeração a água; IV- laser de Er:YAG com refrigeração a água. Em todos os grupos foram utilizados dez dentes, com exceção do grupo III, que teve uma amostra de apenas cinco dentes, uma vez que foi impossível realizar os preparos adequadamente com o laser sem refrigeração. Os aumentos de temperatura foram gravados num computador ligados aos termopares e os dados dos grupos I, lI e IV foram submetidos ao teste de Dunn para comparações múltiplas (p<0,05). Os aumentos médios de temperatura foram: 11,64°C para o grupo I, 0,96°C para o grupo II, 40,86°C para o grupo lll e 2,9°C para o grupo IV. Não houve diferenças estatisticamente significantes entre os grupos II e IV, e estes foram diferentes do grupo I. Os preparos cavitários realizados com as turbinas de alta-rotação e com o laser de Er:YAG geraram aumentos de temperatura semelhantes quando sob refrigeração a água. A refrigeração é essencial para evitar aumentos de temperatura agressivos em ambos os casos e com o laser de Er:YAG é especialmente necessária para a ablação do esmalte / The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel
208

Resistência ao cisalhamento de diferentes sistemas adesivos no esmalte dental

Paradella, Thaís Cachuté [UNESP] 02 February 2005 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:23:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-02. Added 1 bitstream(s) on 2015-12-10T14:29:49Z : No. of bitstreams: 1 000321044.pdf: 3854644 bytes, checksum: 01ab2d1605e6fa7494856c8a92d98414 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar in vitro três sistemas adesivos: um monocomponente com condicionamento ácido prévio (GI Prime & Bond 2.1), um primer autocondicionante (GII Clearfil SE Bond) e um adesivo autocondicionante (GIII One Up Bond F), através da resistência ao cisalhamento no esmalte de dentes humanos, avaliando-se o tipo de fratura por estereomicroscopia. Trinta pré-molares armazenados em solução de cloramina a 0,5% receberam cortes em sentido médio-distal e tiveram suas superfícies de esmalte planificadas. Os espécimes foram aleatoriamente divididos nos três grupos experimentais (n=20). A área de atuação dos adesivos foi delimitada e os procedimentos adesivos realizados conforme recomendações dos fabricantes. Cilindros de resina composta Z-250 de 3mm de diâmetro foram confeccionados. Os espécimes foram armazenados em água destilada a 37°C por 24h, termociclados por 500 ciclos (5°C-55°C) e cisalhados com velocidade de 0,5mm/min. As médias de resistência adesiva foram Gl 18,13 ± 6,49 MPa, com 55% de fraturas coesivas em resina composta; Gll 17,12 ± 5,80 MPa com 90% de fraturas adesivas e Glll 10,47 ± 3,14 MPa com 85% de fraturas adesivas. Os dados foram submetidos à análise estatística ANOVA e comparação múltipla de Tukey (5%), não havendo diferenças significantes entre o Gl e o GIl, tendo o Glll diferença significante em relação aos outros grupos. O tipo de fratura mais predominante (adesiva do GIl) foi submetido à MEV e observou-se a ruptura na interface resina-dente. Concluiu-se que o adesivo do Gl promoveu resistência de valor semelhante ao GII, porém com tipo de fratura diferente / The purpose of this study was to evaluate in vitro three adhesive systems: a total etch single-component (GI Prime & Bond 2.1 ), a self-etching primer (GII Clearfil SE Bond) and a self-etching adhesive (GIII One Up Bond F), through shear bond strength on enamel of human teeth, evaluating the type of fracture through stereomicroscopy. Thirty premolars, kept in 0.5% chloramines solution received cuts in mesium-distal sense and had their ena mel surfaces prepared. They were randomly assigned to three experimental groups (n=20). The adhesive system's area of acting was determined and the adhesive procedures were performed according to the manufactureis instructions. 3mm Z-250 composite resin cylinders were performed. The specimens were kept in distilled water at 370C for 24h, thermocycled for 500 cycles (5ºC-55ºC) and submitted to shear with 0.5mm/min speed. The adhesive resistance mediums were GI 18.13 ± 6.49 MPa, with 55% of resin cohesive fractures; GII 17.12 ± 5.80 MPa with 90% of adhesive fractures and GIII 10.47 ± 3.14 MPa with 85% of adhesive fractures. The data was submitted to Anova and Tukey multiple comparison (5%) statistical analysis. There were no significant differences between Gl and GIl, having GIII significant difference regarding the other groups. The predominant type of fracture (adhesive in GIl) was submitted to SEM and the rupture in the resin-tooth interface was noticeable. lt was concluded that the adhesive system in Gl presented similar shear bond strength to GIl, however with a different type of fracture
209

Avaliação clínica dos efeitos da associação do peróxido de hidrogênio a 38% com o peróxido de carbamida a 10%

Machado, Lucas Silveira [UNESP] 03 May 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-05-03Bitstream added on 2014-06-13T19:01:39Z : No. of bitstreams: 1 machado_ls_dr_araca.pdf: 4244386 bytes, checksum: 44f19a1237c274ea1f5b5a1532dd4547 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo clínico foi avaliar os efeitos da associação de técnicas clareadoras com peróxido de hidrogênio (clareamento de consultório) e de carbamida (clareamento caseiro), na alteração de cor, sensibilidade dental, na morfologia e rugosidade superficial do esmalte dental. Fizeram parte dessa pesquisa clínica 21 voluntários, com faixa etária de 18-25 anos. Foram utilizados, de acordo com as especificações do fabricante, o produto clareador a base de peróxido de hidrogênio a 38% Opalescence Boost PF (Ultradent Products Inc., UT, EUA) e o a base de peróxido de carbamida a 10% Opalescence (Ultradent Products Inc., UT, EUA). O fator em estudo foi a “técnica clareadora” em 2 níveis: Técnica 1 (clareamento de consultório associado com clareamento caseiro) e Técnica 2 (apenas clareamento caseiro). Inicialmente, os voluntários tiveram suas hemi-arcadas superiores direita ou esquerda submetidas ao clareamento de consultório com 3 aplicações de 15 minutos cada de peróxido de hidrogênio a 38% ou placebo (Fase 1), respectivamente, caracterizando assim, um delineamento tipo split-mouth ou de boca dividida. Durante os 7 dias seguintes à Fase 1, os voluntários realizaram o clareamento caseiro utilizando o peróxido de carbamida a 10%, por 4 horas diárias (Fase 2) em ambos os lados; a Fase 1 e 2 foram repetidas por mais uma vez na semana seguinte. A mensuração da variável alteração de cor foi realizada nos incisivos e caninos superiores, pelo método visual (Vita Classical, Vita Zahnfabrik, Germany) e digital (Vita Easyshade, Vita Zahnfabrik, Germany), antes e após a Fase 1 e ao final do experimento; a variável sensibilidade foi analisada pelo método analógico visual; enquanto que as alterações da superfície de esmalte e... / The objective of this clinical study was to evaluate the association between two dental bleaching techniques — hydrogen peroxide bleaching (in-office bleaching) and carbamide peroxide (home bleaching) – and color change, dental sensitivity, morphology, and superficial roughness of dental enamel. Were performed two applications according to the manufacturer's specifications, one per week, of the in-office bleachingwith38% hydrogen peroxide. We applied the home bleaching technique for two weeks with 10% carbamide peroxide in a custom-made tray. The factor studied was the bleaching technique on 2 levels: Technique 1 (in-office bleaching associated with home bleaching) and Technique 2 (home bleaching only).The response variables were color change, dental sensitivity, morphology, and superficial roughness. According to a random draw, the volunteers had their maxillary right and left hemi arches submitted to in-office placebo treatment and to in-office bleaching, respectively (Phase 1), and at home bleaching (Phase 2) treatment for both hemi-arches, characterizing a split-mouth type of design. The color change was performed in the incisor and canine teeth by visual and digital evaluation before and after phase 1 and after the conclusion of each session of attendance. The dental sensitivity was assessed using the visual analogical method whereas the enamel surface changes and roughness were analyzed by electron microscopy (SEM) and by optical interferometry (IFM), through replicas clinically obtained based on central incisors before and after bleaching procedures. No differences were observed between the bleaching techniques for both the visual and digital analysis. There was a significant difference in the dental sensitivity... (Complete abstract click electronic access below)
210

Protocolo de modelagem tridimensional do primeiro pré-molar superior para o método dos elementos finitos e análise das concentrações de tensões na região cervical do esmalte

Silva, Adriana de Oliveira [UNESP] 05 August 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-08-05Bitstream added on 2014-06-13T21:02:27Z : No. of bitstreams: 1 silva_ao_dr_arafo.pdf: 47247453 bytes, checksum: cfa1fd5d9b336cf113128352c96116a9 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo objetivou a descrição de um protocolo para modelagem tridimensional de um primeiro pré-molar superior hígido para o método dos elementos finitos e a validação do modelo pela análise da distribuição de tensões de tração na região cervical do esmalte vestibular quando submetido à aplicação de cargas oclusais fisiológicas e não-fisiológicas, relacionando os resultados obtidos com os estudos dos mecanismos formadores das lesões de abfração descritos na literatura. Projetou-se anatomia das estruturas envolvidas a partir de referenciais arquitetônicos básicos da morfologia dental descritos na literatura científica. As dimensões anatômicas vestibular, oclusal e mesial do dente hígido e estruturas de suporte foram desenhadas em papel milimetrado, escaneados e com 3DSMax® -Autodesk, modelados tridimensionalmente. O modelo foi exportado para o NeiNastran® -Noran Engineering, Inc., onde foram definidas as propriedades das estruturas biológicas, além da geração da malha de elementos finitos e condições de contorno. Foi analisada a tensão tração presente no modelo de onde se concluiu que houve diferenças significativas na distribuição de tensão entre os grupos analisados. As simulações de oclusão não-fisiológica interferiram acentuadamente na distribuição de tensões quando comparados com a oclusão fisiológica, sendo que a localização dos pontos de maior concentração de tensão de tração variou de acordo com a topografia do carregamento aplicado. A simulação de prematuridade retrusiva apresentou os maiores valores de tensão de tração na região cervical vestibular de esmalte. / The main objective of this study is the description of a protocol for threedimensional modeling of the first maxillary premolar using finite elements methodology by the validation of the stress analysis distribution in the cervical region of the enamel when submitted to the physiological occlusion load and nonphysiological, relating the results obtained with the studies of mechanisms that causes the described injuries due to abfraction in literature. The involved structures were designed using basic architectural of the dental morphology described in scientific literature. The vestibular, occlusal and mesial anatomical dimensions of the tooth and support structures were drawn in milimetric paper, scanned and modeled three-dimensionally by 3DSMax® - Autodesk. The model was exported to the NeiNastran® - Noran Engineering, Inc., where the finite elements mesh and further biological properties of the structures and constraints were set. The traction tension at the model was analyzed and it was concluded that appeared significant differences the distribution of tension between the analyzed groups. The simulation of non-physiological occlusion cases had highly interfered at the distribution of tensions when compared with the physiological occlusion cases. Moreover, the localization of the regions of bigger concentration of tension was related with the topography variation of the applied load. The simulation of retruded prematurity presented the biggest values of tension in the cervical enamel region.

Page generated in 0.0275 seconds