11 |
Codificação Eficiente de Sinais de Eletrocardiograma / Efficient Coding of ECG signalsAraújo, Enio Aguiar de 28 May 2010 (has links)
Made available in DSpace on 2016-08-17T14:53:09Z (GMT). No. of bitstreams: 1
Enio Aguiar de Araujo.pdf: 4163087 bytes, checksum: 164f9ddea4dce2f8f19d8e66d5e8294f (MD5)
Previous issue date: 2010-05-28 / Typically, in the digital processing of electrocardiography signal, linear
transformations are used to turn the signals more tractable in accordance to some
application. For applications such as classification or data compression, it usually
aimed to reduce the redundancy present in the signals, increasing the potential of the
applications. There are various methods usually used for the task, the Fourier transform,
the wavelet transform and principal component analysis. All those methods have any sort
of limitation, being the use of a predefined space, orthogonal spaces or the limitations to
second order statistics. In this work we propose the use of the independent component
analysis method for the encoding of the ECG signals, using as theoretical basis the
neuroscience concept of efficient coding. Two important results were found, the basis
functions space generated by the proposed method is different from the spaces seen on
the usual methods, and, on average, the method can reduce the redundancy of the signal.
We concluded that the traditional methods might not exploit the coding potential of
ECG signals due to their limitations, and also that ICA might be a reliable method for
improving the performance comparing to the current systems. / Tipicamente, em processamento digital de sinais de eletrocardiografia, são
utilizadas transformações lineares visando tornar os sinais mais tratáveis de acordo com a
aplicação. Para aplicações como classificação ou compressão de dados, normalmente temse
como objetivo dessas transformações, reduzir a redundãncia presente nesses sinais,
o que aumenta o potencial dessas aplicações. Existem diversos métodos usualmente
utilizados para essa tarefa, como a transformada de Fourier, a transformada de Wavelets,
e análise de componentes principais. Todos esses métodos tem alguma limitação, seja a
utilização de um espaço predefinido e ortogonal ou utilizar apenas estatística de segunda
ordem. Neste trabalho propomos a utilização do método de análise de componentes
independentes para a codificação de sinais de ECG utilizando como base o conceito da
neurociência de codificação eficiente. Dois resultados importantes foram obtidos, o espaço
de funções bases gerado pelo método proposto se diferencia dos espaços de transformações
utilizados usualmente, e, em média, o método proposto teve maior capacidade de reduzir
a redundância dos sinais. Concluímos que os métodos tradicionais podem não explorar
ao máximo o potencial de codificação de sinais de ECG devido às suas limitações, e que
ICA pode ser um método plausível para melhorarmos os sistemas atualmente utilizados.
|
12 |
Compressão de sinais de eletrocardiograma utilizando análise de componentes independentes / COMPRESSION OF ELETROCARDIOGRAMA SIGNALS USING ANALYSIS OF INDEPENDENT COMPONENTSGuilhon, Denner Robert Rodrigues 24 February 2006 (has links)
Made available in DSpace on 2016-08-17T14:53:12Z (GMT). No. of bitstreams: 1
Denner Guilhon.pdf: 761750 bytes, checksum: 0100d830816d0600a5ff8aacd65531cb (MD5)
Previous issue date: 2006-02-24 / The continuing demand for high performance and low cost electrocardiogram
processing systems have required the elaboration of even more efficient and reliable ECG
compression techniques. The objective of this work is to evaluate the performance of an
electrocardiogram (ECG) compression algorithm based on independent components analysis
(ICA). To each of the ECG signal we processed, using ICA, vectorial subspaces composed of
its basis functions were obtained, for the signal can be expressed as a linear combination of
them.
The ECG signal was subdivided into m fixed length windows, and each of them
was projected in the subspace, resulting in a vector w of coefficients for each window. A
simple quantization process was performed over the m vectors w, according to defined levels of
quantization, each one generating different levels of reconstruction error.
It was observed that the storage of the coefficients implies the use of less space in
memory in comparison to that one used by the corresponding windows of the electrocardiogram
signal. The reconstruction error measure traditionally used, the percent root mean-square
difference (PRD), was used into the evaluation of the algorithm. The results had been compared
with those obtained using the Karhunen Lo´eve transform (KLT). / A demanda contınua de por sistemas de processamento de eletrocardiogramas de
alto desempenho e baixo custo tem exigido a elaboração de técnicas de compressão de ECG
cada vez mais eficientes e confiáveis. O objetivo deste trabalho é avaliar o desempenho de
um algoritmo baseado em análise de componentes independentes (ICA) para a compressão de
eletrocardiogramas (ECGs). Para cada um dos sinais de ECG utilizados foram obtidos, através
de ICA, subespaços vetoriais construıdos a partir de suas funções base, pois o sinal pode ser
expresso como uma combinação linear destas.
O sinal de ECG foi subdividido em m janelas de comprimento fixo, e cada uma
delas foi projetada no subespaço, resultando em um vetor w de coeficientes para cada janela.
Um processo de quantização simples foi executado para os m vetores w, segundo nıveis de
quantização definidos, cada um gerando diferentes nıveis de erro de reconstrução.
Foi observado que o armazenamento dos coeficientes implica na utilização de um
menor espaço em memória em comparação àquele utilizado pelas janelas correspondentes
do sinal de eletrocardiograma. A medida tradicionalmente utilizada de erro de reconstrução,
diferença média quadrática percentual (PRD), foi empregada para a avaliação do algoritmo. Os
resultados foram comparados àqueles obtidos utilizando a transformada de Karhunen Loeve
(KLT).
|
13 |
Avaliação da adaptação entre implantes e pilar protético do tipo hexágono externo considerando a rugosidade superficial / Evaluation of adaptation between implant and prosthetic abutment hexagon external type considering the roughness surfaceSak, Luiz Fernando de Moura 13 December 2016 (has links)
No Brasil o numero de pacientes deficientes orais ainda é crescente, o edentulismo é caracterizado como uma condição evitável em que um ser humano tem perda completa dos dentes, que, segundo a organização mundial da saúde, surge em a consequência de um sistema de saúde deficiente que afeta a saúde geral da população, bem como a sua qualidade de vida. Com objetivo de tratar esta deficiência surgem os implantes dentários, uma das modalidades mais praticadas na atualidade em ciências médicas, com uma taxa de sobrevida de 95% a longo prazo em estudos publicados. O objetivo deste trabalho foi avaliar por meio de interferometria ótica 3D as superfícies de união de implantes Hexágono externo e seu pilar protético universal de quatro marcas vendidas no mercado nacional, quanto seus parâmetros de lisura Sa (rugosidade média) e mensurar metricamente o nível de adaptação entre o pilar protético e implantes utilizando microscopia eletrônica de varredura. Foram escolhidas quatro marcas de implantes do tipo hexágono externo e quatro pilares protéticos do tipo universal para próteses cimentadas de quatro diferentes fabricantes disponíveis no mercado brasileiro, para cada amostra implante ou pilar protético foram feita 06 medições para estabelecer uma média de rugosidade das superfícies sob os parâmetros de rugosidade Sa, Ssk e Sku, na sequência unidas e realizadas 06 medições em MEV para avaliar a qualidade do gap. Após a avaliação, os dados foram submetidos a ANOVA, teste t (0,05) e regressão linear dos dados. Onde descarta-se a hipótese igualdade entre as marcas com 95% de confiança para os parâmetros Sa e Gap, porém o teste “t”dois fatores revelam igualdade entre as marcas 01 e 02 para o valor de Sa e Gap nos implantes e igualdade entre as marcas 01 e 03 dos valores Sa dos pilares protéticos. / In Brazil the number of oral deficient patients is still increasing, edentulismo is characterized as an avoidable condition in which a human being has complete loss of teeth, which, according to the world health organization, arises in the consequence of a poor health system Which affects the general health of the population, as well as their quality of life. In order to treat this deficiency, dental implants arise, one of the most practiced modalities in the medical sciences today, with a 95% long-term survival rate in published studies. The objective of this work was to evaluate the external bonding surfaces of the external Hexagon implants and its universal prosthetic pillar of four brands sold in the Brazilian market through its 3D optical interferometry, as well as its smoothness parameters (mean roughness) and to measure the adaptation level Between the prosthetic abutment and implants using scanning electron microscopy. Four brands of external hexagon type implants and four universal type prosthetic abutments were selected for cemented prostheses from four different manufacturers available in the Brazilian market. For each implant sample or prosthetic abutment, measurements were made to establish a roughness mean of the surfaces under Roughness parameters Sa, Ssk and Sku, in the sequence joined and performed 06 MEV measurements to evaluate the quality of the gap. After the evaluation, the data were submitted to ANOVA, t test (0.05) and linear regression of the data. Where the hypothesis equality between the brands with 95% confidence for the Sa and Gap parameters is discarded, but the "t" test two factors reveals equality between the 01 and 02 marks for the value of Sa and Gap in the implants and equality between Marks 01 and 03 of the values Sa of the prosthetic abutments.
|
14 |
An?lise do efeito de polimorfismos n?o-sin?nimos em genes de reparo de DNA da via BER na resposta inflamat?ria da meningiteSilva, Thayse Azevedo da 21 March 2013 (has links)
Made available in DSpace on 2014-12-17T14:05:23Z (GMT). No. of bitstreams: 1
ThayseAS_TESE.pdf: 2133799 bytes, checksum: c236c1e72798e2c7e1008d1c78d046a4 (MD5)
Previous issue date: 2013-03-21 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico / In vitro and in animal models, APE1, OGG1, and PARP-1 have been proposed as being involved with inflammatory response. In this work, we have investigated if the SNPs APE1 Asn148Glu, OGG1 Ser326Cys, and PARP-1 Val762Ala are associated to meningitis and also developed a system to enable the functional analysis of polymorphic proteins. Patients with bacterial meningitis (BM), aseptic meningitis (AM) and controls (non-infected) genotypes were investigated by PIRA-PCR or PCR-RFLP. DNA damages were detected in genomic DNA by Fpg treatment. IgG and IgA were measured from plasma and the cytokines and chemokines were measured from cerebrospinal fluid samples using Bio-Plex assays. The levels of NF-?B and c-Jun were measured in CSF by dot blot assays. A significant (P<0.05) increase in the frequency of APE1 148Glu allele in BM and AM patients was observed. A significant increase in the genotypes Asn/Asn in control group and Asn/Glu in BM group was also found. For the SNP OGG1 Ser326Cys, the genotype Cys/Cys was more frequent (P<0.05) in BM group. The frequency of PARP-1 Val/Val genotype was higher in control group (P<0.05). The occurrence of combined SNPs increased significantly in BM patients, indicating that these SNPs may be associated to the disease. Increasing in sensitive sites to Fpg was observed in carriers of APE1 148Glu allele or OGG1 326Cys allele, suggesting that SNPs affect DNA repair activity. Alterations in IgG production were observed in the presence of SNPs APE1Asn148Glu, OGG1Ser326Cys or PARP-1Val762Ala. Reductions in the levels ofIL-6, IL-1Ra, MCP-1/CCL2and IL-8/CXCL8 were observed in the presence of APE1148Glu allele in BM patients, however no differences were observed in the levels of NF-?B and c-Jun considering genotypes and analyzed groups. Using APE1 as model, a system to enable the analysis of cellular effects and functional characterization of polymorphic proteins was developed using strategies of cloning APE1 cDNA in pIRES2-EGFP vector, cellular transfection of the construction obtained, siRNA for endogenous APE1 and cellular cultures genotyping. In conclusion, we obtained evidences of an effect of SNPs in DNA repair genes on the regulation of immune response. This is a pioneering work in the field that shows association of BER variant enzymes with an infectious disease in human patients, suggesting that the SNPs analyzed may affect immune response and damage by oxidative stress level during brain infection. Considering these data, new approaches of functional characterization must be developed to better analysis and interactions of polymorphic proteins in response to this context / Estudos in vitro e em modelos animais sugerem que as prote?nas de reparo de DNA da via de reparo por excis?o de bases (do ingl?s, BER) APE1, OGG1 e PARP-1 est?o envolvidas tamb?m na resposta inflamat?ria. Neste trabalho foi investigado se os SNPs APE1 Asn148Glu, OGG1 Ser326Cys e PARP-1 Val762Ala associam-se ? meningite, e foi desenvolvido um sistema para an?lise funcional destas variantes polim?rficas. Os gen?tipos de pacientes com meningite bacteriana (MB), meningite ass?ptica (MA) e n?o infectados (controles) foram investigados por PIRA-PCR ou PCR-RFLP. Danos no DNA gen?mico foram detectados por meio de tratamento com Fpg. IgG e IgA foram titulados no plasma e citocinas e quimiocinas foram mensuradas em amostras de l?quor atrav?s de ensaios em Bio-Plex. Os n?veis de NF-?B e c-Jun foram dosados no l?quor dos pacientes por meio de dot blot. Foi observado um aumento significativo (P<0.05) na frequ?ncia do alelo APE1 148Glu nos casos de MB e MA. Os gen?tipos Asn/Asn no grupo controle e Asn/Glu no grupo da MB tamb?m apresentaram relevante aumento em suas frequ?ncias (P<0.05). Para o SNP OGG1 Ser326Cys, o gen?tipo Cys/Cys esteve mais frequente (P<0.05) nos casos de MB. A frequ?ncia do gen?tipo PARP-1 Val/Val foi mais alta no grupo controle (P<0.05). A ocorr?ncia combinada dos SNPs foi significativamente alta nos pacientes com MB, indicando que estes SNPs podem estar associados ? doen?a. Os portadores do alelo APE1 148Glu ou OGG1 326Cys apresentaram um n?mero maior de s?tios sens?veis ? Fpg, sugerindo que os SNPs afetam a atividade de reparo do DNA. Altera??es na s?ntese de IgG foram observadas na presen?a dos SNPs APE1 Asn148Glu, OGG1 Ser326Cys ou PARP-1 Val762Ala. Redu??es nos n?veis de IL-6, IL-1Ra, MCP-1/CCL2 e IL-8/CXCL8 foram encontradas na presen?a do alelo APE1 148Glu em amostras de pacientes com MB, no entanto n?o foram encontradas diferen?as nos n?veis de NF-?B e c-Jun considerando os gen?tipos e os grupos analisados. Utilizando APE1 como modelo, foi desenvolvido um sistema que possibilita a express?o e caracteriza??o funcional das enzimas polim?rficas estudadas e seus efeitos na c?lula, por meio de clonagem, utilizando o vetor pIRES2-EGFP e cDNA de APE1, transfec??o celular da constru??o obtida, inibi??o por siRNA de APE1 end?gena e genotipagem de culturas celulares. Em conclus?o, foram obtidas evid?ncias de um efeito significativo dos SNPs nos genes de reparo de DNA na regula??o da resposta imunol?gica. Este ? um trabalho pioneiro na ?rea, que demonstra a associa??o de variantes das enzimas da via BER com uma doen?a infecciosa em humanos, sugerindo que os SNPs estudados podem afetar a resposta imune e o impacto do n?vel de estresse oxidativo durante a infec??o cerebral. Desta forma, novos meios de an?lise funcional devem ser desenvolvidos para estudo de prote?nas polim?rficas e suas intera??es neste contexto / 2020-01-01
|
15 |
Avaliação da viabilidade da implementação da tecnologia de gelificação na produção de insumos para diagnóstico / Evaluating the use of gelification technology for the production of diagnostic kitsCosta, Maykon Luiz Nascimento 26 September 2017 (has links)
Dentre os países da América Latina, o Brasil é o país que mais recebe doações de sangue em volume, alcançando mais de 3,5 milhões de bolsas anualmente só na hemorrede pública. Para que possam ocorrer as transfusões e processamento de hemoderivados é mandatória a realização de testes para detecção de agentes patológicos. Neste cenário está inserido o Instituto de Biologia Molecular do Paraná (IBMP) que, em parceria com a FIOCRUZ, é responsável pelo fornecimento do kit NAT destinado a detecção dos vírus da imunodeficiência humana (HIV), hepatite C (HCV) e hepatite B (HVB) à hemorrede pública brasileira. Visando implementar melhorias e novas tecnologias aos processos existentes, o Instituto adquiriu a licença para utilização da técnica de gelificação na produção de kits para diagnóstico. Esta técnica propõe a estabilização de biomoléculas sem afetar sua funcionalidade, proporcionando a redução de custos de produção, além de possibilitar que os kits sejam armazenados e transportados à temperatura ambiente, aspecto fundamental para simplificar sua cadeia logística e viabilizar a distribuição destes produtos em áreas remotas do Brasil e do mundo. No entanto, ainda há escassez de trabalhos que avaliem aspectos financeiros da implementação desta técnica na indústria. Cabe salientar ainda que a realização de testes em campo seria complexa e demandaria um alto investimento. Uma alternativa para realizar este tipo de avaliação é pelo uso de simulação computadorizada do processo. As ferramentas de simulação possibilitam avaliar diferentes cenários, obtendo dessa forma informações imprescindíveis para melhoria operacional e para tomada de decisões. Neste trabalho, são avaliados os impactos da implementação da técnica de gelificação no custo direto de produção de insumos para diagnóstico por meio de simulação discreta usando o software FlexSim®. Dados obtidos a partir de dezesseis cenários simulados usando a nova tecnologia foram comparados com registros históricos do IBMP na produção de insumos para diagnóstico pelo processo convencional. Dentre os cenários avaliados, seis atenderam às restrições impostas pelo processo e em todos foi possível verificar a redução nos custos diretos, que variou de 3,73% até 5,41% em relação às condições atuais. As reduções de custo ocorreram principalmente devido a reduções nos custos com matéria-prima, que alcançaram economia de 4,1% e nos custos com mão de obra, dada redução do número de operadores no processo. Ademais, os resultados indicam que a implementação da tecnologia propicia melhor aproveitamento da estrutura física da planta sem que ocorra saturação de linhas de processamento. Portanto, baseado em modelos de simulação, este trabalho demonstra a viabilidade do emprego da tecnologia de gelificação no IBMP em termos de custo direto de produção de insumos para diagnóstico. / Among Latin American countries, Brazil is the one that receives more blood donations in volume, reaching up to 3.5 million blood bags in the public blood donation network annually. In order to enable transfusions and processing of blood-derived products, it is mandatory to test the blood against pathologic agents. In association with the Oswaldo Cruz Foundation (FIOCRUZ), the Molecular Biology Institute of Paraná (IBMP) supplies the kit NAT for the detection of the human immunodeficiency, hepatitis B and C viruses (HIV, HBV and HCV) to the Brazilian public blood donation network. Aiming at the implementation of improvements and the introduction of new technologies to its processes, the Institute acquired a license to use the gelification technique in the production of diagnostic kits. The gelification technique proposes the stabilization of biomolecules without harming their functionality, while reducing production costs and allowing the products to be stored and transported at room temperature. It is a key aspect to simplify the logistics chain used to distribute the kit, allowing it to reach World`s remote areas. However, there is still a lack of published studies evaluating financial aspects of the implementation of this technique in the industry. It is worth emphasizing the cost to conduct field experiments of this kind of implementation. One alternative for such an evaluation is by the use of process computer simulation. Simulation tools could be used to analyze different scenarios, providing valuable information for process improvement and decision-making. In this work, the impacts of the gelification technique implementation in the direct production cost of reagents for diagnostic were evaluated using discrete simulation with FlexSim®. Data obtained from sixteen simulated scenarios deploying gelification were compared with historic records of the production of reagents for diagnosis using the conventional process at IBMP. Six of the sixteen evaluated scenarios satisfied the restrictions imposed by the process and all of them indicated a reduction of direct production costs, varying from 3.73% to 5.41% when compared to current conditions. The cost reduction is mainly associated to lower expenses with raw materials, representing savings of up to 4.1% and to the reduction in the number of operators needed. Additionally, results indicate that the implementation of the new technology leads to a better use of the physical structure of the production facility without saturating processing lines. Therefore, based on simulation models, this work shows that the employment of the gelification technology in the manufacturing process of diagnostic reagents at IBMP is viable in terms of direct production costs.
|
16 |
Utilização de corrente microgalvânica para o desenvolvimento de dois protocolos para tratamento de estrias albas / Utilization of microgalvanic current for the development of two protocols for treatment of alba stretch marksCosta, Cristiane Ferreira da 07 October 2016 (has links)
O desenvolvimento de estrias durante a gestação é considerado a alteração fisiológica mais comum do tecido conjuntivo e poucas são as alternativas de tratamento destinadas a suavizar a aparência dessa alteração. O presente estudo desenvolveu e aplicou dois protocolos para o tratamento de estrias albas surgidas durante o período gestacional utilizando a corrente microgalvânica e verificando seus efeitos. Tratou-se de um estudo exploratório, experimental, de abordagem quantitativa e qualitativa, composto por 26 voluntárias com faixa etária entre 20 e 35 anos divididas igualmente em dois grupos. Iniciou-se o estudo após a assinatura do Termo de Consentimento Livre e Esclarecido. Ambos os grupos receberam 15 sessões de tratamento com a corrente microgalvânica modulada em 100µA (microampères) sendo uma sessão a cada 12 dias de intervalo. O grupo A recebeu o tratamento com a técnica de punturação longitudinal e o grupo B recebeu a técnica de punturação transversal. Todas as voluntárias responderam a um questionário relatando a intensidade da dor, tipo de dor e a satisfação com o tratamento, e passaram por avaliação fisioterapêutica no início, após a quinta, décima e décima quinta sessão do protocolo de tratamento proposto. Todas as estrias foram tratadas, contudo, três estrias de cada voluntária foram selecionadas para serem acompanhadas, sendo fotografadas e tendo sua área, comprimento e largura analisados por meio do software ImageJ, da planimetria manual e da paquimetria. A cada cinco sessões houve uma comparação dos resultados obtidos dentro de cada um dos grupos e também entre os grupos a fim de avaliar qual o melhor protocolo e qual a quantidade necessária de sessões para aproximar a aparência das estrias escolhidas à da pele considerada normal. O grupo A apresentou diferença significativa após cinco sessões de tratamento enquanto o grupo B necessitou de 15 sessões para apresentar resultado semelhante ao grupo A na redução do tamanho das estrias. Todavia, os dois protocolos aplicados foram efetivos na redução do tamanho das estrias. Na comparação entre grupos para intensidade da dor foi encontrado diferença estatisticamente significativa (p=0,000) para o grupo A que apresentou dor maior em relação ao grupo B. Relativamente à satisfação das mulheres com o tratamento não houve diferença estatisticamente significativa entre os grupos. No grupo A 38,4% das voluntarias relataram muita satisfação, 53,8% satisfação e 7,7% pouca satisfação com o tratamento. O grupo B relatou 38,4% de muita satisfação, 46,5% satisfação e 15,4% de pouca satisfação com o tratamento. / The development of stretch marks during pregnancy is considered the most common physiological change of connective tissue and there are few alternative treatments designed to soften the appearance of this change. This study developed and applied two protocols for the treatment of striae alba arising during pregnancy using microgalvanic current and checking its effects. This was an exploratory study, experimental, quantitative and qualitative approach, consisting of 26 volunteers aged between 20 and 35 years also divided into two groups. It began the study after signing the Statement of Consent. Both groups received 15 treatment sessions with the microgalvanic current modulated 100μA (microamps) being a session every 12 days apart. Group A received the treatment with the longitudinal puncturing technique and the B group received the cross puncturing technique. All participants answered a questionnaire on the intensity of pain, type of pain and satisfaction with treatment, and underwent physical therapy evaluation at the beginning, after the fifth, tenth and fifteenth session of the proposed treatment protocol. All streaks were treated, however, three streaks of each volunteer was selected to be monitored being shot and having its area, length and width analyzed using the ImageJ software, manual planimetry and pachymetry. The five sessions was a comparison of the results within each group and between groups in order to assess what is the best protocol and wherein the required amount of sessions to approximate the appearance of the striae chosen to be normal skin. Group A showed significant differences after five treatment sessions while the B group needed 15 sessions to present results similar to group A in reducing the size of stretch marks. However, the two applicable protocols were effective in reducing the size of striae. In the comparison between groups for pain intensity was found statistically significant (p = 0.000) for group A which showed greater pain than in group B. With regard to women's satisfaction with the treatment, there was no statistically significant difference between groups. In group A, 38.4% of voluntary reported great satisfaction, 53.8% and 7.7% satisfaction little satisfaction with treatment. The B group reported 38.4% of great satisfaction, 46.5% and 15.4% satisfaction low satisfaction with treatment.
|
17 |
Proposta de modelo de gestão de confiança para internet das coisas médicas / A Model Proposal for Trustworthiness Management for Internet of Medical ThingsBrittes, Marisangela Pacheco 07 December 2016 (has links)
Nos últimos anos, o paradigma da Internet das Coisas (IoT) foi introduzido, ganhando relevância como uma tecnologia emergente, composta por redes amplamente conectadas e heterogêneas. No contexto médico essas redes suportam diferentes tipos de processos, sendo compostas por diversos tipos de dispositivos denominados objetos, os quais são capazes de interagir uns com os outros, colaborando para atingir um objetivo comum (diagnóstico, tratamento, monitoramento e reabilitação de pacientes). Este cenário caracteriza-se como Internet de Coisas Médicas (IoMT) e um dos maiores desafios a serem superados é o desenvolvimento de mecanismos de gestão de confiança para assegurar trocas de dados com um certo nível de credibilidade. Este trabalho propõe um modelo para gestão de confiança em redes IoMT a partir de conceitos de redes sociais e critérios de relevância biomédica. O modelo proposto baseia-se em um índice de recomendação calculado por um protocolo determinístico de gestão de confiança. Para avaliar sua eficácia, foram criadas simulações com diferentes cenários de redes IoMT. O modelo demonstrou ser útil para detectar objetos com comportamento suspeito na rede, evitando o estabelecimento de relações com estes objetos e minimizando os danos causados à IoMT durante as trocas de dados. / In recent years, the Internet of Things (IoT) paradigm has been introduced, getting attention as an emerging technology, built upon pervasive connectivity of objects in heterogeneous networks. Medical environments are composed by many devices named objects that are able to interact with each other and collaborate in order to achieve a common objective (diagnosis, treatment, monitoring and patient rehabilitation). This scenario is characterized as Internet of Medical Things (IoMT) and one of its greatest challenges is to develop trustworthiness mechanisms to assure data exchanges in a certain level of credibility. This work proposes a model to manage trustworthiness for IoMT networks based on social network concepts and biomedical relevance criteria. The proposed model is based on a trust recommendation index, computed by a deterministic trustworthiness management protocol. To evaluate the model effectiveness, simulations were created with different IoMT scenarios. The model demonstrated to be useful to detect objects with suspicious behavior in the network, avoiding their relationships establishment and minimizing the IoMT damage during the data exchanges.
|
18 |
Utilização de corrente microgalvânica para o desenvolvimento de dois protocolos para tratamento de estrias albas / Utilization of microgalvanic current for the development of two protocols for treatment of alba stretch marksCosta, Cristiane Ferreira da 07 October 2016 (has links)
O desenvolvimento de estrias durante a gestação é considerado a alteração fisiológica mais comum do tecido conjuntivo e poucas são as alternativas de tratamento destinadas a suavizar a aparência dessa alteração. O presente estudo desenvolveu e aplicou dois protocolos para o tratamento de estrias albas surgidas durante o período gestacional utilizando a corrente microgalvânica e verificando seus efeitos. Tratou-se de um estudo exploratório, experimental, de abordagem quantitativa e qualitativa, composto por 26 voluntárias com faixa etária entre 20 e 35 anos divididas igualmente em dois grupos. Iniciou-se o estudo após a assinatura do Termo de Consentimento Livre e Esclarecido. Ambos os grupos receberam 15 sessões de tratamento com a corrente microgalvânica modulada em 100µA (microampères) sendo uma sessão a cada 12 dias de intervalo. O grupo A recebeu o tratamento com a técnica de punturação longitudinal e o grupo B recebeu a técnica de punturação transversal. Todas as voluntárias responderam a um questionário relatando a intensidade da dor, tipo de dor e a satisfação com o tratamento, e passaram por avaliação fisioterapêutica no início, após a quinta, décima e décima quinta sessão do protocolo de tratamento proposto. Todas as estrias foram tratadas, contudo, três estrias de cada voluntária foram selecionadas para serem acompanhadas, sendo fotografadas e tendo sua área, comprimento e largura analisados por meio do software ImageJ, da planimetria manual e da paquimetria. A cada cinco sessões houve uma comparação dos resultados obtidos dentro de cada um dos grupos e também entre os grupos a fim de avaliar qual o melhor protocolo e qual a quantidade necessária de sessões para aproximar a aparência das estrias escolhidas à da pele considerada normal. O grupo A apresentou diferença significativa após cinco sessões de tratamento enquanto o grupo B necessitou de 15 sessões para apresentar resultado semelhante ao grupo A na redução do tamanho das estrias. Todavia, os dois protocolos aplicados foram efetivos na redução do tamanho das estrias. Na comparação entre grupos para intensidade da dor foi encontrado diferença estatisticamente significativa (p=0,000) para o grupo A que apresentou dor maior em relação ao grupo B. Relativamente à satisfação das mulheres com o tratamento não houve diferença estatisticamente significativa entre os grupos. No grupo A 38,4% das voluntarias relataram muita satisfação, 53,8% satisfação e 7,7% pouca satisfação com o tratamento. O grupo B relatou 38,4% de muita satisfação, 46,5% satisfação e 15,4% de pouca satisfação com o tratamento. / The development of stretch marks during pregnancy is considered the most common physiological change of connective tissue and there are few alternative treatments designed to soften the appearance of this change. This study developed and applied two protocols for the treatment of striae alba arising during pregnancy using microgalvanic current and checking its effects. This was an exploratory study, experimental, quantitative and qualitative approach, consisting of 26 volunteers aged between 20 and 35 years also divided into two groups. It began the study after signing the Statement of Consent. Both groups received 15 treatment sessions with the microgalvanic current modulated 100μA (microamps) being a session every 12 days apart. Group A received the treatment with the longitudinal puncturing technique and the B group received the cross puncturing technique. All participants answered a questionnaire on the intensity of pain, type of pain and satisfaction with treatment, and underwent physical therapy evaluation at the beginning, after the fifth, tenth and fifteenth session of the proposed treatment protocol. All streaks were treated, however, three streaks of each volunteer was selected to be monitored being shot and having its area, length and width analyzed using the ImageJ software, manual planimetry and pachymetry. The five sessions was a comparison of the results within each group and between groups in order to assess what is the best protocol and wherein the required amount of sessions to approximate the appearance of the striae chosen to be normal skin. Group A showed significant differences after five treatment sessions while the B group needed 15 sessions to present results similar to group A in reducing the size of stretch marks. However, the two applicable protocols were effective in reducing the size of striae. In the comparison between groups for pain intensity was found statistically significant (p = 0.000) for group A which showed greater pain than in group B. With regard to women's satisfaction with the treatment, there was no statistically significant difference between groups. In group A, 38.4% of voluntary reported great satisfaction, 53.8% and 7.7% satisfaction little satisfaction with treatment. The B group reported 38.4% of great satisfaction, 46.5% and 15.4% satisfaction low satisfaction with treatment.
|
19 |
Proposta de modelo de gestão de confiança para internet das coisas médicas / A Model Proposal for Trustworthiness Management for Internet of Medical ThingsBrittes, Marisangela Pacheco 07 December 2016 (has links)
Nos últimos anos, o paradigma da Internet das Coisas (IoT) foi introduzido, ganhando relevância como uma tecnologia emergente, composta por redes amplamente conectadas e heterogêneas. No contexto médico essas redes suportam diferentes tipos de processos, sendo compostas por diversos tipos de dispositivos denominados objetos, os quais são capazes de interagir uns com os outros, colaborando para atingir um objetivo comum (diagnóstico, tratamento, monitoramento e reabilitação de pacientes). Este cenário caracteriza-se como Internet de Coisas Médicas (IoMT) e um dos maiores desafios a serem superados é o desenvolvimento de mecanismos de gestão de confiança para assegurar trocas de dados com um certo nível de credibilidade. Este trabalho propõe um modelo para gestão de confiança em redes IoMT a partir de conceitos de redes sociais e critérios de relevância biomédica. O modelo proposto baseia-se em um índice de recomendação calculado por um protocolo determinístico de gestão de confiança. Para avaliar sua eficácia, foram criadas simulações com diferentes cenários de redes IoMT. O modelo demonstrou ser útil para detectar objetos com comportamento suspeito na rede, evitando o estabelecimento de relações com estes objetos e minimizando os danos causados à IoMT durante as trocas de dados. / In recent years, the Internet of Things (IoT) paradigm has been introduced, getting attention as an emerging technology, built upon pervasive connectivity of objects in heterogeneous networks. Medical environments are composed by many devices named objects that are able to interact with each other and collaborate in order to achieve a common objective (diagnosis, treatment, monitoring and patient rehabilitation). This scenario is characterized as Internet of Medical Things (IoMT) and one of its greatest challenges is to develop trustworthiness mechanisms to assure data exchanges in a certain level of credibility. This work proposes a model to manage trustworthiness for IoMT networks based on social network concepts and biomedical relevance criteria. The proposed model is based on a trust recommendation index, computed by a deterministic trustworthiness management protocol. To evaluate the model effectiveness, simulations were created with different IoMT scenarios. The model demonstrated to be useful to detect objects with suspicious behavior in the network, avoiding their relationships establishment and minimizing the IoMT damage during the data exchanges.
|
20 |
Análise da disponibilidade de equipamentos médico-assistenciais após reestruturação da programação de manutenção preventiva em um hospital público de grande porte e alta complexidadeGodoi, Carolina Mendes de 02 December 2016 (has links)
CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A organização hospitalar utiliza atualmente uma diversidade de tecnologias, merecendo o cuidado e o estudo de profissionais habilitados que atuam na Engenharia Clínica. Porém, o aumento da disponibilidade dessas tecnologias nos Estabelecimentos Assistenciais de Saúde (EASs) é sempre um grande desafio a ser gerenciado. Assim, os programas de manutenção preventiva (MP) de Equipamentos Médico-Assistenciais (EMAs) se apresentam como importante ferramenta de gestão no alcance desse objetivo. Diante disso, este trabalho apresenta a reestruturação da programação de MPs de EMAs, visando o aumento da disponibilidade dos mesmos, em um hospital público de grande porte e alta complexidade. O estudo foi realizado no Hospital de Clínicas de Uberlândia da Universidade Federal de Uberlândia (HCU-UFU) e foram levados em consideração 11 equipamentos médico-assistenciais de 24 famílias diferentes. A metodologia utilizada foi baseada no estudo dos manuais operacionais e técnicos dos equipamentos, nas normas técnicas em vigência, nas antigas manutenções preventivas dos EMAs, na experiência dos profissionais de Engenharia Clínica da BioEngenharia do HCU-UFU e nas necessidades do EAS. Foram alteradas periodicidades sugeridas nos manuais devido à quantidade de técnicos disponíveis para a realização da manutenção, a quantidade e disponibilidade de EMAs, e o custo de peças e acessórios para a execução dessas MPs. Foram desenvolvidos também os Procedimentos Operacionais Padrão (POPs) referentes a cada manutenção preventiva do EMA. As manutenções preventivas apresentadas nesse trabalho já estão cadastradas e em execução na BioEngenharia e até o presente momento têm funcionado de maneira eficaz, o que pôde ser confirmado pela análise da disponibilidade onde das 24 famílias de EMAs, 21 mostraram percentuais de disponibilidade superiores após a implementação da reestruturação das MPs e pela análise estatística que mostrou um p-valor < 0,05 para a hipótese de que a disponibilidade das famílias de equipamentos médico-assistenciais analisados é maior depois da restruturação das manutenções preventivas. / The hospital organization currently uses several technologies, requering care and study of qualified professionals of Clinical Engineering. However, increasing the availability of technologies in Health Care Facilities (HCF) is always a great challenge. An important tool to find this objective is the programs of preventive maintenance (PM) of Medical Assistance Equipment (MAE). Thus, aiming to increase availability of MAE, this work presents the restructuring of PM programming, in a large public hospital with high complexity. The study was carried out at the Hospital of the Federal University of Uberlândia (HCU-UFU), using 11 Medical Assistance Equipment from 24 different families. The method used was based on the study of the operational and technical manuals of the equipment, current technical standards, previous preventive maintenance of the MAE, experience of the Clinical Engineering professionals of the HCU-UFU BioEngenharia and the needs of the HCF. Periodicity suggested in the manuals were altered due to the number of technicians available for maintenance, the quantity and availability of MAE, and the cost of parts and accessories for the execution of PM. Standard Operating Procedures (SOP) were also developed for each preventive maintenance of MAE. The preventive maintenance presented in this work are registered and it is working at HCU-UFU BioEngenharia and they are working effectively, which is confirmed by two ways. Firstly, analysis of the availability of 24 families of MAE, showed that 21 families had higher percentages of availability after implementation of the restructuring of the PM. Secondly, statistical analysis showed that the availability of the families of medical assistance equipment analyzed is greater after the restructuring of the preventive maintenance, with p-value < 0.05. / Dissertação (Mestrado)
|
Page generated in 0.0498 seconds