91 |
Desenvolvimento de um dispositivo de teste dinâmico para avaliação da estabilidade de imagens de ressonância magnética funcionalCapaverde, Alexandre da Silva January 2014 (has links)
Made available in DSpace on 2014-07-11T02:03:01Z (GMT). No. of bitstreams: 1
000459163-Texto+Completo-0.pdf: 4581609 bytes, checksum: 9c2157ae4d5d0fdce6a15da19b6c7c45 (MD5)
Previous issue date: 2014 / Among the protocols for quality control of magnetic resonance equipment is to evaluate the stability of the sequence EPI (Echo-Planar Imaging), this used in imaging method called functional magnetic resonance imaging. Nowadays, static and homogeneous test devices are recommended for this review. This work proposes the development of a dynamic test device for quality control of the stability of EPI sequences. The test device consists of an acrylic box, where two brackets are inserted, through which passes a tube in which a liquid circulates signal producing. At certain times during acquisition, is injected through a fuel injection pump, a solution of copper sulfate and gadolinium in order to produce variations in signal intensity in the region of the hose, over time. To validate the device, images were acquired in a magnetic resonance with 3. 0 T during the period of a month, on Monday morning and evening and on Tuesday morning in order to evaluate machine wear.For each acquisition were evaluated: (1) the standard deviation of average normalized signal intensity in the region of the images corresponding to the homogeneous region of the liquid; (2) the average normalized signal intensity at baseline and injection in the image region corresponding to the hose; (3) the difference between the mean of baseline and injection; (4) the signal to noise ratio in the region of the images corresponding to the homogeneous region. As a result there was an increase in the standard deviation in the homogeneous region of the liquid from the acquisitions made on Monday evening. There was also wide variation in the difference between the baseline and injection line, and in one day this went from approximately 0. 3 to 0. 6 after five acquisitions and on another day of approximately 0. 7 to 0. 5 after a single acquisition. The test has been validated for use in 3. 0 T equipment and that additional tests are needed to verify the reproducibility of the results. / Dentre os protocolos de controle da qualidade de equipamentos de ressonância magnética está a avaliação da estabilidade da sequência EPI (Echo-Planar Imaging), esta utilizada no método de imageamento denominado ressonância magnética funcional. Atualmente, dispositivos de teste estáticos e homogêneos são recomendados para esta avaliação. Este trabalho propõe o desenvolvimento e validação de um dispositivo de teste dinâmico para avaliar a estabilidade de sequências EPI. O dispositivo de teste consiste em uma caixa de acrílico, onde são inseridos dois suportes, através dos quais passa uma mangueira, na qual circula um líquido produtor de sinal. Em determinados momentos durante a aquisição, é injetada, por meio de uma bomba injetora, uma solução de sulfato de cobre e gadolínio com o objetivo de produzir variações na intensidade de sinal, na região da mangueira, ao longo do tempo. Para validar o dispositivo, foram adquiridas imagens em um equipamento de ressonância magnética de 3,0 T, durante o período de um mês, nas segundas-feiras pela manhã e pela noite e nas terças-feiras pela manhã para avaliar o desgaste do equipamento.Para cada aquisição foram avaliados: (1) o desvio padrão da média de intensidade de sinal normalizada na região das imagens correspondente à região homogênea do líquido; (2) a média de intensidade de sinal normalizada nas linhas de base e de injeção na região da imagem correspondente à mangueira; (3) a diferença entre as médias das linhas de base e de injeção; (4) a razão sinal-ruído na região das imagens correspondente à região homogênea. Como resultado houve um aumento no desvio padrão na região homogênea do líquido nas aquisições realizadas nas segundas-feiras à noite. Houve ainda grande variação na diferença entre a linha de base e a linha injeção, sendo que em um dia esta passou de aproximadamente 0,3 para 0,6 após cinco aquisições e em outro dia de aproximadamente 0,7 para 0,5 após uma única aquisição. O dispositivo de teste foi validado para utilização em equipamentos de 3,0 T sendo que testes adicionais são necessários para verificar a reprodutibilidade dos resultados obtidos.
|
92 |
Desenvolvimento e avaliação de protótipo para estudos de neuroimagem: estímulo olfativoMondini, Renata January 2014 (has links)
Made available in DSpace on 2015-02-06T01:01:37Z (GMT). No. of bitstreams: 1
000465061-Texto+Parcial-0.pdf: 182147 bytes, checksum: f7a4815079fd1da1390d1f0d759a33b8 (MD5)
Previous issue date: 2014 / This dissertation presents the development and evaluation of a prototype for the stimulus of the olfactory system, which will be employed in the study of neuroimages gathered by functional magnetic resonance image (fRMI). Basic requirements for the prototype include: safety, human physiology and environmental compatibility, homogeneous release of aerosolized stimuli, accurate control of pressure and flow conditions, support for up to three distinct substances, and substance mixing capability. Digital image processing techniques were used in evaluation process through the usage of Matlab in order to better assess the reliability and reproducibility in the evaluation of the of the samples released under controlled constant pressure of 3. 5+/- 0. 3 kgf/cm², different flows (4 l/min, 6 l/min, 8 l/min and 10 l/min), and different duration periods (10s, 15s, 20s, 30s, 60s and 90s). Charts with the image profiles, histograms and statistical data were generated and analyzed. The delay in the system, important information for any study in fRMI, was measured using an oxygen sensor and custom software solution. Experiments for the determination of the amount of substance required and the real capability of mixing substances were performed with parameters based on the results from the digital image processing analysis. / Esta dissertação de mestrado apresenta o desenvolvimento e a avaliação de um protótipo para estimular o sistema olfativo, o qual será empregado em estudos de neuroimagens obtidas pela modalidade de ressonância magnética funcional. Para o desenvolvimento do protótipo foram definidos requisitos básicos que o sistema deveria possuir: segurança, compatibilidade com o ambiente e com as características fisiológicas humanas, dispensar amostra aerossolizada, precisão para controlar e regular vazão e pressão, capacidade para três substâncias distintas e possibilidade de misturá-las. A avaliação utilizou técnicas de processamento de imagens digitais com a utilização do software Matlab com a finalidade de estudar a confiabilidade e reprodutibilidade na quantificação da amostra dispensada utilizando pressão fixa de 3,5 +/- 0,3 kgf/cm² e as variáveis fluxo (4 l/min, 6 l/min, 8 l/min e 10 l/min) e tempo (10s, 15s, 20s, 30s, 60s e 90s). Os resultados foram analisados através de gráficos de perfil dos pixels, histogramas e dados estatísticos das imagens. O atraso do sistema, dado fundamental para pesquisas em ressonância magnética funcional, foi medido com a utilização de um sensor de oxigênio e um software desenvolvido em LabVIEW. Experimentos para medir o consumo e a possibilidade de misturar as amostras foram realizados utilizando os resultados obtidos com a validação por processamento de imagens digitais.
|
93 |
Aplicação da espectroscopia de ressonância paramagnética eletrônica e técnicas complementares no estudo dos compósitos restauradores fotopolimerizáveisFontes, Adriana da Silva 25 September 2009 (has links)
Os compósitos fotopolimerizáveis ainda requerem muitos estudos, pois, por não se polimerizarem completamente, apresentam alguns inconvenientes que podem omprometer a longevidade da restauração dentária. Diante disso, torna-se cada vez maior o interesse em realizarem-se novas investigações com metodologias que possam contribuir para um melhor entendimento das propriedades físico-químicas deste produto. Nesse contexto, o presente trabalho visa colaborar mostrando que a espectroscopia de Ressonância Paramagnética Eletrônica (RPE) combinada com as análises convencionais, pode trazer informações importantes sobre o processo de polimerização desse material restaurador estético. Inicialmente, oito tipos de compósitos comerciais, do tipo fotopolimerizável foram utilizados nesta investigação: FILTEKTM Z350 (3M ESPE), FILTEKTM Z250 (3M ESPE), Z100 (3M ESPE), Opallis (FGM), Charisma (Heraues Kulzer), Master Fill (Biodinâmica), Suprafill (SSWhite) e Fillmagic (Vigodent). Foram utilizadas para a fotopolimerização das amostras uma fonte halógena (Kehr XR Light) e uma fonte LED -Ultra Blue (Dabi Atlante). Devido à natureza do radical gerado durante o processo de fotopolimerização, a espectroscopia de RPE foi empregada para sondar o comportamento dessa espécie paramagnética sob diversas condições. Em adição, técnicas experimentais de Espectroscopia de Absorção na região do Infravermelho por Transformada de Fourier, resistência mecânica (flexural e compressão), microdureza superficial, contração volumétrica, profundidade de polimerização, Microscopia Eletrônica de Varredura, Sistema de Energia Dispersiva,Sorção e Solubilidade, Testes de Raspagens e Análise da Translucidez foram realizadas para a obtenção de informações adicionais. A combinação desses métodos foi utilizada com sucesso facilitando a compreensão do comportamento do material em estudo. Através da análise dos dados obtidos por RPE foi possível comprovar que a polimerização continua ocorrendo mesmo após o encerramento da fotopolimerização; que o espectro de RPE tem a contribuição de duas espécies de radicais; que a dose de irradiação deve ser diferenciada para as resinas, sendo dependente da composição química, da cor do compósito e do grau de translucidez, entre outros fatores, tendo esses, influencia significativa sobre o desempenho mecânico do material; A resina re-irradiada, após 24h da irradiação, gerou novos radicais, indicando que parte dos agentes iniciadores da polimerização ainda não haviam reagido; a resina armazenada em água a 370C apresenta uma polimerização mais rápida. Os resultados das técnicas utilizadas se complementam e indicam que a resina que gerou maior número de radicais livres, identificada por RPE, apresenta melhor qualidade. / The photopolymerizated composites still requesty many studies, because, for no polymerized themselves completely, they show some inconveniences that can commit the longevity of the dental restoration. For this, it is every time larger the interest in new investigations with methodologies that can contribute to a better understanding of the physiochemical properties of this product. In this context, the present work intends to collaborate showing that the spectroscopy of Electron Paramagnetic Resonance (EPR) combined with the conventional analyses, can bring important information on the polymerization process of this aesthetic restoring material. Initially, eight types of commercial composites, of the type photocurable were used in this investigation: FILTEKTM Z350 (3M ESPE), FILTEKTM Z250 (3M ESPE), Z100 (3M ESPE), Opallis (FGM), Charisma (Heraues Kulzer), Master Fill (Biodinâmica), Suprafill (SSWhite) and Fillmagic (Vigodent). They were used for the photo activation of the samples a halogenic source (Kehr XR Light) and a source LED Ultra Blue (Dabi Atlante). Due to the nature of the radical generated during the photopolymerization process, EPR spectroscopy was used to probe the behavior of that paramagnetic species under several conditions. In addition, Fourier Transform Infrared spectroscopy (FTIR), and experimental techniques of mechanical resistance (flexural and compression), microhardness, volumetric contraction, polymerization depth, Scanning Electron Microscopy, Energy Dispersive System (EDS), sorption and solubility, tests of scratching and measure of the translucency degree were accomplished for the obtaining of additional information. The combination of those methods was used with success facilitating the understanding of the material behavior under study. Through the analysis of the data obtained by EPR was possible to verify that the polymerization continues doing happen after the conclusion of the photopolymerization; that the spectrum of EPR show the contribution of two species of radicals; that the irradiation dose should be differentiated for the resins, being dependent of the chemical composition, of the composite color and of the translucency degree, among other factors, these have significant influences on the mechanical acting of the material; The re-irradiated resin, after 24h of irradiation generated new radicals, indicating that a fraction of the initiators agents of the polymerization had not reacted still; the resin stored in water at 370C showed a faster polymerization. The results of the used techniques are complemental and they indicate the resin that generated larger number of free radicals, identified for EPR, show better quality.
|
94 |
Métodos avançados de ressonância magnética de crânio na diferenciação entre radionecrose e recidiva tumoralLongo, Maria Gabriela Figueiró January 2015 (has links)
JUSTIFICATIVA E OBJETIVO: Muitos estudos reportaram o benefício dos métodos avançados de ressonância magnética (RM) para a avaliação da resposta ao tratamento do tumor cerebral, a fim de distinguir entre recidiva tumoral e radionecrose. No entanto, o tamanho da amostra em cada estudo é relativamente pequeno, o que torna difícil avaliar a validade externa. Nós realizamos uma revisão sistemática e metanálise de dados publicados afim de avaliar a acurácia dos métodos avançados de RM para diferenciação entre a recidiva e a radionecrose. Nosso objetivo foi determinar o valor diagnóstico da difusão (DWI), da perfusão Dynamic Susceptibility Contrast (PWI DSC), perfusão Dynamic Contrast Enhancement (PWI DCE) e espectroscopia (MRS). MATERIAL E MÉTODOS: A revisão sistemática incluiu todos os estudos que usaram métodos avançados de RM para detectar recidiva ou radionecrose em pacientes em segmento por tratamento radioterápico para tumor cerebral. A pequisa foi realizada nas bases de dados MEDLINE e Embase, das publicações até 31 de Julho de 2015. As sensibilidades e especificidades de cada estudo foram calculadas e a acurácia diagnóstica foi metanalisada, com um intervalo de confiança (IC) de 95%, em um modelo de efeito randômico. Foram realizados testes de heterogeneidade, sobre o efeito dos pontos de corte e modelos de metarregressão. Análises de subgrupos foram feitas com base em conjuntos de estudos com características homogêneas. RESULTADOS: 49 artigos foram incluídos na análise quantitativa, englobando um total de 1.508 pacientes. Cinco estudos avaliaram DWI, 32 avaliaram PWI e 21 avaliaram MRS. A sensibilidade (SEN) e especificidade (ESP) geral da DWI foi 81,0% (IC 95%: 71,0 a 89,0%) e 68,0% (IC 95%: 52,0 a 82,0%), respectivamente. A SEN e ESP da PWI DSC foi de 83,0% (IC 95%: 80,0 a 86,0%) e 81,0% (IC 95%: 76,0 a 85,0%) e da PWI DCE foi 76,0% (IC 95%: 66,0 a 85,0%) e 85,0% (IC 95%: 74,0 a 93,0%), respectivamente. A SEN e ESP da MRS foi de 76,0% (IC 95%: 71,0 a 80,0%) e 83,0% (IC 95%: 77,0 a 88,0%), respectivamente. O odds ratio diagnóstico (DOR) da DWI, PWI DSC, PWI DCE e MRS foi 14,83; 25,81; 14,45 e 27,39; respectivamente. O maior valor do DOR nos estudos com PWI DSC foi quando o ponto de corte do Volume Sanguíneo Cerebral relativo (rCBV) foi maior ou igual a 1,8 e o maior valor do DOR nos estudos com MRS foi quando o ponto de corte da relação Cho/Cr foi maior ou igual a 1,3. O valor do DOR nos estudos com MRS foi muito maior nos trabalhos realizados com equipamento de 3T (DOR = 40,07; IC 95%: 15,44 a 104,03) quando comparado aos trabalhos realizados em equipamento com 1,5T (18,69; IC95%: 8,32 a 42,02). CONCLUSÃO: Esta metanálise demonstrou que os métodos avançados de RM tem uma moderada e alta acurácia na diferenciação da recidiva tumoral da radionecrose usando os métodos de DWI, PWI DSC, PWI DCE e MRS. Algumas análises de subgrupos e testes de efeito do ponto de corte mostraram que alguns cenários têm uma tendência de melhor acurácia. / BACKGROUND AND PURPOSE: Several studies reported the benefit of magnetic resonance (MR) advanced methods for the treatment response of brain tumor assessment, for distinguishing tumor recurrence from radionecrosis in gliomas and other brain tumors. However, the sample size in each study is relatively small, which becomes difficult to draw conclusions about external validity. We performed a systematic review and meta-analysis of published data to evaluate the accuracy of the advanced MR methods for differentiating recurrence from radionecrosis. Our objective was to determine the diagnostic value of Diffusion (DWI), Dynamic Susceptibility Contrast Perfusion (PWI DSC), Dynamic Contrast Enhancement Perfusion (PWI DCE) and Spectroscopy (MRS), and compare the results between the methods MATERIALS AND METHODS: The systematic review included all studies that used MR advanced methods to detect recurrence or radionecrosis in patients followed by brain tumor radiotherapy. The databases selected were MEDLINE and Embase, for published data prior to July 31, 2015. The sensitivities and specificities of individual studies were calculated and the pooled diagnostic accuracies, with 95% confidence intervals (CI), were assessed under a random-effects model. It was also performed heterogeneity test, threshold effect test and meta-regression models for each MR method. A subgroup analysis was performed based on homogeneous subsets of the studies. RESULTS: 49 articles were included in the quantitative analysis, compromising 1,508 patients (919 with recurrence and 589 with radionecrosis). Five studies assessed DWI, 32 assessed PWI, and 21 assessed MRS. Overall sensitivity (SEN) and specificity (SPE) of DWI were 81.0% (95% CI: 71.0 to 89.0%) and 68.0% (95% CI: 52.0 to 82.0%), respectively. The SEN and SPE of PWI DSC were 83.0% (95% CI: 80.0 to 86.0%) and 81.0% (95% CI: 76.0 to 85.0%) and PWI DCE were 76.0% (95% CI: 66.0 to 85.0%) and 85.0% (95% CI: 74.0 to 93.0%), respectively. The SEN and SPE of MRS were 76.0% (95% CI: 71.0 to 80.0%) and 83.0% (95% CI: 77.0 to 88.0%), respectively. The overall diagnostic odds ratio (DOR) of DWI, PWI DSC, PWI DCE, and MRS were 14.83, 25.81, 14.45, and 27.39, respectively. The point with the highest DOR in the PWI DSC studies was when the relative Cerebral Blood Volume (rCBV) threshold was equal or higher than 1.8, and the point with the highest DOR in the MRS studies was when the Cho/Cr threshold was equal or higher than 1.3. The MRS DOR value is much higher in the 3T subgroup (40.07, 95% IC: 15.44 to 104.03), compared to the 1.5T subgroup (18.69, 95% CI: 8.32 to 42.02). CONCLUSIONS: This meta-analysis showed that MR advanced methods have moderate to high accuracy in differentiating tumor recurrence from radiation necrosis using DWI, PWI DSC, PWI DCE and MRS. Some subgroup analysis and threshold effect tests demonstrated subsets that have a better accuracy trend.
|
95 |
Estoques e composição química dos diferentes compartimentos da matéria orgânica do solo afetados pela introdução do monocultivo de pinusAlmeida, Henrique Cesar January 2011 (has links)
Este trabalho teve por objetivo investigar possíveis mudanças na composição química da matéria orgânica do solo em áreas de pastagem natural localizadas no planalto catarinense que sofreram a introdução do monocultivo de Pinus, além de investigar a relação entre a composição química de ácidos húmicos extraídos de solo e de carvão mineral e índices de fluorescência. A introdução de Pinus aumentou a acidez do solo, diminuiu o teor de seus nutrientes e aumentou os estoques de carbono na camada de 0-5 cm. Isso se verificou em todos os compartimentos químicos da matéria orgânica do solo. O Pinus também provocou aumento na aromaticidade da matéria orgânica do solo e em todos os seus compartimentos. Em subsuperfície, a mudança na vegetação promoveu uma redistribuição dos compartimentos químicos da matéria orgânica do solo, diminuindo seu caráter hidrofílico e aumentando seu caráter hidrofóbico. Em solos sob Pinus, as interações organo-minerais foram relevantes até 15 cm de profundidade, enquanto que em ambiente de pastagens esse mecanismo foi pronunciado principalmente na camada de 0-5 cm. Os índices de fluorescência e o deslocamento batocrômico do λmáx de emissão das soluções contendo as misturas de ácidos húmicos aumentaram com a maior proporção de ácido húmico de solo. A introdução de grupos nitro em sua estrutura também afetou os fenômenos de fluorescência observados. / This work aimed to investigate possible changes on the amount and on the chemical composition of the soil organic matter of pastures areas from the planalto catarinense caused by the introduction of the Pinus monoculture. Additionally, the relationship between the chemical composition of humic acids extracted from soil and from mineral coal and fluorescence indexes were further investigated. The Pinus introduction increased soil acidity, decreased nutrients content and increased carbon stocks in the 0-5 cm layer. This last result occurred in all chemical compartments of the soil organic matter. Pinus also promoted the increase of soil organic matter aromaticity in all compartments. In subsurface, the change off vegetation promoted the redistribution of the chemical compartments of soil organic matter, decreasing its hydrophilic character and increasing its hydrophobic character. In soils under Pinus, organo-mineral interactions were relevant until 15 cm depth, while in soil under pasture this mechanism was pronounced until 5 cm depth. Fluorescence indexes and the batochromic shift of the emission λmáx of the humic acids suspensions increased with the increase of soil humic acids proportion in the mixture. The introduction of nitro groups in their structure affected also the observed fluorescence behavior.
|
96 |
"Avaliação da doença de Alzheimer através da espectroscopia de prótons por ressonância magnética: comparação entre os achados no cíngulo posterior e nos hipocampos" / Evaluation of Azheimer's Disease using Magnetic Resonance Spectroscopy : comparation of findings in the posterior cingulate and hippocampiHae Won Lee 26 October 2005 (has links)
Foi realizada a comparação entre os achados de espectroscopia de prótons por ressonância magnética utilizando a sequência PRESS (point resolved spectroscopy), com TE curto (35ms) no cíngulo posterior e hipocampos de 29 pacientes com doença de Alzheimer (leve e moderada) e 15 controles. As relações de metabólitos com melhor sensibilidade e especificidade na diferenciação entre os grupos foram em ordem decrescente: Naa/Cr do cíngulo, mI/Naa do cíngulo, mI/Naa dos hipocampos e mI/Cr dos hipocampos. Não houve vantagens, nesta casuística, na realização da espectroscopia de prótons nos hipocampos, um local tecnicamente mais difícil e demorado em relação ao cíngulo posterior. Observou-se correlação positiva da relação Naa/Cr e negativa da relação mI/Naa do cíngulo posterior com o MMSE / The objective of this study is to compare the findings on Magnetic Resonance Spectroscopy using PRESS (point resolved spectroscopy) technique with short TE (35ms) in the posterior cingulate and hippocampi of 29 patients with Alzheimer's disease (mild and moderate) and 15 controls. The metabolic ratios with highest sensitivity and specificity were (in a decreasing order): posterior cingulate Naa/Cr, posterior cingulate mI/Naa, hippocampi mI/Naa and hippocampi mI/Cr. In the group analised it seems there is no advantage in performing MRS in the hippocampi instead of posterior cingulate, a technically challenging location, usually leading to a longer examination time. In the posterior cingulate we observed a positive correlation with Naa/Cr ratio and a negative correlation with mI/Naa ratio and the MMSE
|
97 |
Validação de modelos metabonômicos por ressonância magnética nuclear de hidrogênio para predição de fibrose hepática significativa, fibrose hepática avançada e cirrose em pacientes com hepatite C crônica / Validação de modelos metabonômicos por RMN de H1 para predição de fibrose hepática significativa, fibrose hepática avançada e cirrose em pacientes com hepatite C crônicaBATISTA, Andrea Dória 23 February 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-07-17T21:13:26Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
TESE Andrea Dória Batista.pdf: 3733528 bytes, checksum: 118ca9a13fedf2f4a63feac6b2e74c4c (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-07-19T22:44:43Z (GMT) No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
TESE Andrea Dória Batista.pdf: 3733528 bytes, checksum: 118ca9a13fedf2f4a63feac6b2e74c4c (MD5) / Made available in DSpace on 2018-07-19T22:44:43Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
TESE Andrea Dória Batista.pdf: 3733528 bytes, checksum: 118ca9a13fedf2f4a63feac6b2e74c4c (MD5)
Previous issue date: 2017-02-23 / O padrão-ouro na avaliação da fibrose hepática em pacientes com hepatite C crônica (HCC) é a análise histopatológica de fragmento hepático por biópsia, método invasivo, sujeito a complicações e a erros. Alternativamente, biomarcadores vêm sendo testados. A metabonômica é uma estratégia de análise que utiliza espectroscopia de ressonância magnética nuclear de hidrogênio (RMN H1) para classificar biofluidos em função do seu status bioquímico. Este estudo de validação fase II teve como objetivo desenvolver modelos metabonômicos (MMs), através de espectros de RMN H1 de amostras de soro, para predição de fibrose hepática significativa (FS: METAVIR ≥ F2), fibrose avançada (FA: METAVIR ≥ F3), e cirrose (C: METAVIR F4 ou cirrose clínica), em duas populações de pacientes com HCC, nas cidades de Recife/PE e do Rio de Janeiro/RJ, e comparar com os índices APRI e FIB-4, utilizando a biópsia como padrão de referência. Em PE, foram incluídos 69 pacientes com biópsia dos últimos 12 meses ou diagnóstico clínico de cirrose. No RJ, foram incluídos 180 pacientes com biópsia na inclusão. Pacientes com doença hepática por outra etiologia, coinfecção com HBV ou HIV ou ingestão excessiva de etanol foram excluídos. Espectros de RMN H1 foram obtidos utilizando espectrômetro Varian Unity 300. Os MMs foram construídos utilizando os formalismos análise discriminante linear (LDA) e análise discriminante por mínimos quadrados paricais (PLS-DA). Em pacientes de PE, os MMs foram testados por validação cruzada, considerando FS, FA e C, e em pacientes do RJ, por validação cruzada em 126 indivíduos, e por validação externa em 54, considerando FS e FA. Em PE, 42 (61%) pacientes apresentaram FS, 28 (40%) FA e 18 (26%) C. Os MMs apresentaram sensibilidade e especificidade de 97,6% (IC 95%: 87,4-99,9%) e 92,6% (IC 95%: 77,5-99,9%) para predição de FS; 96,4% (IC 95%: 81,7-99,1%) e 95,1% (IC 95%: 83,5-99,4%) para FA; e 100% (IC 95%: 81,5-100%) e 98,0% (IC 95%: 89,6-99,9%) para C. No RJ, 103 (57,2%) pacientes apresentaram FS e 51 (28,3%) FA. Os MMs validados externamente apresentaram sensibilidade e especificidade de 100% (IC 95%: 86,8-100%) e 100% (IC 95%: 87,7-100%) para predição de FS, e de 100% (IC 95%: 71,5-100%) e 100% (IC 95%: 91,8-100%) para FA. O desempenho dos MMs foi similar ao do APRI e FIB-4, nas duas populações, porém, os MMs classificaram corretamente 27 (39,7%) pacientes de PE e 95 (54,3%) do RJ com valores intermediários de APRI, e 25 (36,8%) pacientes de PE e 76 (44,2%) do RJ com valores intermediários de FIB-4, quando não é possível predizer FS e FA por esses índices. Conclui-se que os MMs desenvolvidos apresentaram elevada acurácia para predição de FS, FA e C, em pacientes com HCC de PE e do RJ, e permitiram o estadiamento da fibrose nas zonas cinzas do APRI e FIB-4, sugerindo tratar-se de método promissor como marcador
indireto de fibrose nesses pacientes. Entretanto, serão necessários novos estudos, com maior casuística, a fim de confirmar seu desempenho, para posterior incorporação na prática clínica. / The gold standard in liver fibrosis assessment in patients with chronic hepatitis C (CHV) is histopathological analysis of hepatic fragment by biopsy, an invasive method, subject to complications and errors. Alternatively, biomarkers have been tested. Metabonomics is an analytical strategy that uses nuclear magnetic resonance of hydrogen (1H-NMR) spectroscopy to classify biofluids based on their biochemical status. This phase II validation study aimed to develop metabonomic models (MMs), using 1H-NMR spectra of serum samples, to predict significant liver fibrosis (SF: METAVIR ≥ F2), advanced fibrosis (AF: METAVIR ≥ F3), and cirrhosis (C: METAVIR F4 or clinical cirrhosis), in two populations of CHC patients, in the cities of Recife/ PE and Rio de Janeiro/RJ, and to compare these to the APRI and FIB-4 scores, using biopsy as reference. In PE, 69 patients were included, who had had a biopsy in the last 12 months or clinical diagnosis of cirrhosis. In RJ, 180 patients were included who had had a biopsy on inclusion. Patients with liver disease due to another etiology, co-infection with HBV or HIV or excessive ethanol intake were excluded. 1H-NMR spectra were obtained using a Varian Unity 300 spectrometer. The MMs were constructed using the linear discriminant analysis (LDA) and partial least squares discriminant analysis (PLS-DA) formalisms. For patients of PE, the constructed MMs were tested by cross-validation, considering SF, AF and C and for those of RJ, by cross-validation in 126, and by external validation in 54 patients, considering SF and AF. In PE, 42 (61%) patients had SF, 28 (40%) AF and 18 (26%) C. The MMs presented sensitivity and specificity of 97.6% (95% CI: 87.4-99.9%) and 92.6% (95% CI: 77.5-99.9%) for predicting SF; 96.4% (95% CI: 81.7-99.1%) and 95.1% (95% CI: 83.5-99) for AF; and 100% (95% CI: 81.5-100%) and 98.0% (95% CI: 89.6-99.9%) for C. In RJ, 103 (57.2%) patients presented SF and 51 (28.3%) AF. The externally validated MMs presented sensitivity and specificity of 100% (95% CI: 86.8-100%) and 100% (95% CI: 87.7-100%) for predicting SF, and 100% (95% CI: 71.5-100%) and 100% (95% CI: 91.8-100%) for AF. The performance of the MMs was similar to that of APRI and FIB-4, in both populations, however, the MMs correctly classified 27 (39.7%) PE patients and 95 (54.3%) RJ patients with intermediate values of APRI and 25 (36.8%) PE patients and 76 (44.2%) RJ patients with intermediate values of FIB-4, when it is not possible to predict SF and AF by these scores. It is concluded that the MMs that were developed presented a high accuracy for predicting SF, AF and C in CHC patients of PE and RJ, and allowed the staging of fibrosis in the gray zones of these scores, suggesting that it is a promising method as an indirect marker of fibrosis in these patients. However, further studies, with a larger casuistry, will be necessary in order to confirm its performance, for later incorporation into clinical practice.
|
98 |
Determinação da toxicidade in vitro e in vivo de novos organofosforados e ressonancia magnetica nuclear do cloreto de acetilcolina / Determination of toxicity of the new organophosphorus and nuclear magnetic resonance of acetylcholine chlorideSega, Estela Munhoz 27 April 2006 (has links)
Orientadores: Nelci Fenalti Hoerhr, Roberto Rittner Neto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-06T21:30:04Z (GMT). No. of bitstreams: 1
Sega_EstelaMunhoz_M.pdf: 1403353 bytes, checksum: 0aec5b888298032d359cc1b3cf0905b6 (MD5)
Previous issue date: 2006 / Resumo: Esse estudo analisou as propriedades toxicológicas de novos compostos organofosforados. Foram realizados experimentos para avaliar a atividade anticolinesterásica desses organofosforados, in vitro, no sangue total através do método de Ellman modificado. Para determinar a sua citotoxicidade foram utilizadas células PC 12, com as quais avaliamos a viabilidade celular após contato com os organofosforados e determinamos a IC 50, encontrando valores muito diferentes para os diversos organofosforados estudados. Estudos de toxicidade aguda in vivo foram realizados com camundongos, através da metodologia recomendada pela OECD nos quais determinamos a DL50 para três dos organofosforados estudados, sendo que um apresentou toxidade moderada. Foram analisados os efeitos dos solventes nas constantes de acoplamento JHH, JHH, JNC e 2Jnc em espectros de RMN de LH e 13C do cloreto de acetilcolina. Os valores das constantes de acoplamento em solventes de diferentes constantes dielétricas (s) não sofreram variações, indicando uma ausência de efeitos de solvente no equilíbrio conformacional do cloreto de acetilcolina (ACh). As constantes de acoplamento mostram que o sistema OCH2CH2N+ tem uma conformação gaúche (sinclinal). O Jnh e Jkc são observados na maioria dos solventes, mas não em solventes clorados e não são dependentes da viscosidade do solvente, esse comportamento foi explicado usando dados de medidas de Ti. Os valores dos coeficientes de difusão de RMN mostraram que a ACh tem uma grande tendência de se agregar quando dissolvida em solventes clorados, fato que pode explicar as diferenças observadas em valores de T1 para o 14N / Abstract: This study analyzed the properties of the news organophosphorus. Experiments had been carried through to evaluate the inhibition of acetylcholinesterase of these organophosphorus, in vitro, through the modified EUman's method. In order to determine its cytotoxicity cells PC 12 had been used, with which we evaluate the cellular viability after contact with the organophosphorus and determined the IC50, different values were found for the diverse organophosphorus. Studies of acute toxicity had been carried through with mice, following the methodology recommended by the OECD in which determine the DL50 for three of the organophosphorus studied, being that one presented moderate toxicity. Coupling constants values ( Jhh and Jnc) obtained from the 'H and 13 C NMR spectra of acetylcholine chloride (ACh) in several solvents with a wide range of dielectric constants (e) are remarkably invariant, indicating an absence of solvent effects in the conformational equilibrium of this compound. Those values show that the OCH2CH2N+ system occurs in a synclinal conformation. The Jnh and Jnc are observable in most solvents, but not in chlorine-containing solvents and are not dependent on solvent viscosity. This behavior was explained using data from Ti measurements. The measurement of NMR diffusion coefficients show that ACh has a greater tendency to aggregate when dissolved in chlorinated solvents, a fact that could explain the observed differences in 14N T1 / Mestrado / Patologia Clinica / Mestre em Ciências Médicas
|
99 |
Estudo da viabilidade da utilização da técnica de MRS in vivo em experimentos funcionais / Feasibility study of in vivo MRS for functional experimentsDias, Carlos Sato Baraldi, 1983- 15 August 2018 (has links)
Orientador: Gabriela Castellano / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-15T20:04:30Z (GMT). No. of bitstreams: 1
Dias_CarlosSatoBaraldi_M.pdf: 2085782 bytes, checksum: 169421816d56753ab8dbb39c00e0a51f (MD5)
Previous issue date: 2010 / Resumo: A técnica de espectroscopia por ressonância magnética (MRS, do inglês Magnetic Resonance Spectroscopy)baseada no núcleo do hidrogênio (1 H -MRS)tem sido muito usada em estudos neurológicos na determinação de padrões metabólicos para várias patologias. A informação fornecida por esta técnica é única, pois permite monitorar níveis de metabólitos específicos, envolvidos em vários aspectos da função cerebral. Até o momento, a grande maioria dos estudos de 1 H -MRS in vivo têm sido "estáticos ", no sentido de que uma única medida é feita, sem se preocupar com informação temporal. Isso se deve à baixa razão sinal-ruído inerente a esta técnica, que obriga à realização de aquisições longas e médias temporais, sacrificando a resolução temporal. No entanto,o advento da técnica de ressonância magnética funcional e de outras técnicas de neuroimagem dinâmicas, que medem parâmetros dinâmicos como fluxo sanguíneo, taxa de oxigenação do sangue, atividades elétrica e magnética do cérebro, naturalmente fez surgir o interesse em se ter uma técnica que pudesse fornecer informação dinâmica sobre as vias metabólicas associadas à função cerebral - uma MRS funcional. O objetivo deste trabalho foi, portanto, verificar a viabilidade da utilização da técnica de MRS in vivo em experimentos funcionais, tendo sido o primeiro realizado nesta área, no Brasil. Para isso foi primeiramente realizado um estudo extensivo sobre os poucos trabalhos existentes na área e as bases bioquímicas da ativação neuronal. Em seguida, foram realizados experimentos e desenvolvidos vários métodos de análise para tentar detectar a variação temporal dos principais metabólitos presentes num espectro cerebral (N-acetil-aspartato total: NAA, Creatina total: Cre, grupo Colina: Cho, grupo Glutamato/Glutamina: Glx, e Lactato: Lac)em indivíduos saudáveis, durante um experimento com estímulo visual. Os experimentos apresentaram uma série de dificuldades, e não foi possível alcançar a alta resolução temporal desejada, sendo que a resolução média ficou na ordem de minutos -o que concorda, no entanto, com a maioria dos trabalhos encontrados na literatura. Não detectamos variações significativas nos níveis de NAA, Cre e Cho, o que também está de acordo com a maioria dos estudos encontrados na literatura. Por outro lado, foram encontradas variações nos níveis de Lac (que aumentaram com o estímulo, o que concorda com a literatura, porém não voltaram ao nível basal após o estímulo, o que não concorda), e variações nos níveis do grupo Glx (que aumentaram com o estímulo, voltando em seguida ao nível basal, o que concorda com a literatura). Embora os resultados encontrados não tenham sido totalmente concordantes com a literatura e não tenha sido possível melhorar a resolução temporal (em relação aos trabalhos da literatura), acreditamos que este trabalho deixa uma significativa contribuição através dos diversos protocolos experimentais e métodos de análise testados, e abre o caminho para pesquisas futuras na área / Abstract: The technique of Magnetic Resonance Spectroscopy using the hydrogen nucleus (1 H -MRS) has been widely used for neurologic research for determining metabolic patterns for many pathologies. The type of information provided by this technique is unique, since it allows monitoring specific metabolic concentrations involved in cerebral function.Until now, the majority of the in vivo 1 H -MRS studies have been "static ", meaning that data acquisition is done with no concern for temporal information. The reason for this is the low signal-to-noise ratio (SNR)inherent to this technique, which imposes long acquisitions and time averaging that sacrifices temporal resolution. However, the development of function Magnetic Resonance Imaging (fMRI)and other time resolved neuroimaging techniques, that measure dynamic parameters such as blood flow, blood oxygenation rate, electric and magnetic cerebral activity, naturally brought up the interest on a technique that would allow a time resolved measure of the specific metabolic concentrations involved on cerebral metabolism - something like a functional MRS. Therefore the goal of this work was to study the feasibility of using the in vivo MRS technique for functional experiments, being the .rst of its kind performed in Brazil.To do so,initially an extensive bibliographic research was done, to comprehend not only the details of these experiments but also the neurochemistry behind the MRS signal.Next, experiments were performed and many analysis methods were developed, in order to attempt to detect temporal variations of the main metabolites present on a typical cerebral spectrum (total N-acetyl-aspartic acid: NAA, total Creatine: Cre, total Choline: Cho, Glutamine/Glutamate group: Glx and Lactate: Lac) in healthy subjects, during a visual stimulation experiment. Those experiments presented a series of difficulties and the desired high temporal resolution was not attained, achieving an average resolution of minutes - the same resolution found on the majority of the works published. We did not detect any significant variation of the NAA, Cre or Cho levels, which supports the conclusions of other works published. On the other hand, we detected variations in the Lactate levels (which increased with the stimulus, as reported in other works, but did not return to base-line levels, which disagrees with the published works), and in the Glx levels (which increased with the stimulus, returning to baseline levels after it, which agrees with the published literature). Although the results found are not totally in agreement with the published literature and it was not possible to improve the temporal resolution (compared to published works), we believe that this work leaves a significant contribution to the field, through the experimental protocols and analysis methods tested, and opens paths for future research in this area / Mestrado / Física / Mestre em Física
|
100 |
Sensibilidade e especificidade do nistagmo de privação vertebrobasilar, angiorressonância magnética e Doppler transcraniano no diagnóstico da insuficiência vertebrobasilar relacionada à tontura / Sensitivity and specificity of the vertebro-basilar deprivation nystagmus, magnetic resonance angiography, and transcranial Doppler ultrasound in the diagnosis of the dizziness secondary to vertebro-basilar insufficiencyArlindo Cardoso Lima Neto 11 December 2017 (has links)
Objetivo: Determinar a sensibilidade e a especificidade da pesquisa do nistagmo de privação vertebrobasilar (PNPVB), Angiorressonância magnética (AngioRM), investigação ultrassonográfica cervical e Doppler transcraniano (DTC) em pacientes com diagnóstico clínico de insuficiência vertebrobasilar (IVB). Método: o estudo foi aprovado pela comissão de ética local. Os participantes deram consentimento formal. Foi formado grupo de estudo (GE) e grupo controle (GC) com 12 sujeitos em cada, pareados por sexo e idade, sendo 4 masculinos e 8 femininos, com média de idade de 72,66 (±8.35 anos). Os doentes foram selecionados do Ambulatório de Otoneurologia do HC-FMUSP com idade acima de 55 anos, sem outra provável causa de tonturas. Voluntários assintomáticos do Grupo de Apoio Multidisciplinar ao Idoso Ambulatorial (GAMIA) formaram o GC. Todos os participantes realizaram avaliação cardiogeriátrica para excluir qualquer doença de base que pudesse ser a causa da tontura, que não a IVB. Assim, os dois grupos realizaram a PNPVB, a AngioRM, a avaliação ultrassonográfica cervical e DTC. Resultados: PNPVB, AngioRM e avaliação ultrassonográfica cervical não mostraram diferenças entre os grupos. No DTC, foram detectadas diferenças significantes em cinco variáveis: velocidade do pico sistólico da artéria cerebral média direita (ponto de corte em 76,00; sensibilidade de 0,83; especificidade de 0,75; p=0,012), velocidade diastólica final da artéria basilar (ponto de corte em 24,00; sensibilidade de 0,66; especificidade de 0,66; p=0,028), índice de pulsatilidade (IP) da artéria cerebral média esquerda (ponto de corte em 0,85; sensibilidade de 0,83; especificidade de 0,75; p=0,005), IP da artéria cerebral média direita (ponto de corte em 0,88; sensibilidade de 0,75; especificidade de 0,75; p=0,010), IP da artéria basilar (ponto de corte em 1,01; sensibilidade de 0,91; especificidade de 0,91; p < 0,001). Considerando-se o IP da artéria basilar, calculou-se o poder estatístico para uma amostra com 12 sujeitos em cada grupo, sendo > 95%. Conclusão: a PNPVB e a AngioRM não mostraram diferenças entre os grupos. O DTC mostrou sensibilidade de 91% e especificidade de 91% para o diagnóstico da IVB relacionada à tontura, quando o IP da artéria basilar for maior que 1,01 / Objective: To determine the sensitivity and specificity of the vertebro-basilar deprivation nystagmus (VBDN), magnetic resonance angiography (MRA), cervical ultrasonographic investigation and Transcranial Doppler Ultrasound (TDU) in patients with clinical diagnosis of vertebro-basilar insufficiency (VBI). Methods: The study was approved by the Ethics in Research Committee. The patients gave formal consent for participating in this study. We composed 2 groups: a study group (SG) and a control group (CG), comprised of 12 patients each, with sex- and age-matched patients (4 men and 8 women). Their mean age was 72.66 (±8.35) years. The study group included patients from the neurotology outpatient clinic of the HC-FMUSP who were over 55 years old, without any other possible cause for dizziness than VBI. Asymptomatic volunteers from the geriatrics outpatient clinic were included in the CG. All participants were subjected to evaluation of a cardio-geriatric professional, to exclude any subjacent disease that could cause dizziness other than VBI. Then, both groups were subjected to VBDN, MRA, cervical ultrasonographic investigation and TDU. Results: The VBDN, MRA and cervical ultrasonographic investigation did not demonstrate differences between the groups. The TDU demonstrated that the systolic pulse velocity of the right middle cerebral artery (sensitivity=0.83, specificity=0.75; p=0.028), final diastolic velocity of the basilar artery (sensitivity=0.66; specificity=0.66; p=0.028), pulsatility index (PI) of the left middle cerebral artery (sensitivity=0.83; specificity=0.75; p=0,005), PI of the right middle cerebral artery (sensitivity=0.75; specificity=0.75; p=0.010), and the PI of the basilar artery (sensitivity=0.91; specificity=0.91; p < 0.001) were significantly higher in the diseased group compared to controls. Considering the PI of the basilar artery, we observed that the statistic power of the test was higher than 95%. Conclusion: The VBDN, MRA and cervical ultrasonographic investigation did not demonstrate significant changes in patients with VBI compared to controls. The PI of the basilar artery, measured using the TDU, demonstrated high sensitivity (91%) and specificity (91%) levels in the diagnosis of VBI when the PI was higher than 1.01
|
Page generated in 0.0514 seconds