• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 2
  • 1
  • Tagged with
  • 26
  • 24
  • 10
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação eletromiografica dos musculos masseter e temporal anterior de pacientes assintomaticos, sintomaticos e submetidos a tratamento das desordens temporomandibulares

Silva, Frederico Augusto Peixoto 22 February 2002 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-01T16:25:04Z (GMT). No. of bitstreams: 1 Silva_FredericoAugustoPeixoto_D.pdf: 3954505 bytes, checksum: 1002dd13c954a742d6c2b65ea790443c (MD5) Previous issue date: 2002 / Resumo: O objetivo desse trabalho foi comparar os valores da atividade eletromiográfica dos músculos masséter e temporal anterior com a mandíbula na posição de repouso, e em máxima intercuspidação habitual, e ainda determinar o coeficiente de simetria muscular em 44 mulheres na faixa etária entre 18 e 40 anos, com história negativa de bruxismo. As pacientes foram selecionadas de acordo com critérios pré-determinados e divididas por conveniência em três grupos: assintomáticas (G.CONT, n=14), com desordens temporomandibulares (G.DTM, n=16) e tratadas de desordens temporomandibulares (G.TRAT, n=14). As avaliações da atividade eletromiográfica foram realizadas com o sistema K6-1 (Myotronics-Noromed Inc. Tukwila, WA). Os resultados foram submetidos ao Teste não paramétrico de Mann-Whitney, com nível de significância de 5%. Durante a posição de repouso mandibular, a atividade do músculo masséter no G.CONT apresentou valores significativamente menores que os do G.DTM e do G.TRAT. No músculo temporal anterior, o G.DTM apresentou valores significativamente maiores que os do G.TRAT. Durante a máxima intercuspidação habitual no músculo masséter, os valores do G.CONT foram significativamente maiores que os do G.DTM, e no músculo temporal anterior, os valores do G.CONT foram significativamente maiores que os do G.DTM e do G.TRAT. A análise do coeficiente de simetria muscular em ambos os músculos, tanto na posição de repouso quanto na máxima intercuspidação habitual, não revelou diferenças entre os grupos. Pode-se concluir que: pacientes assintomáticos apresentam menor atividade eletromiográfica durante a posição de repouso e maior atividade durante a máxima intercuspidação habitual; pacientes com DTM apresentam maior atividade eletromiográfica durante a posição de repouso e menor atividade durante a máxima intercuspidação habitual; pacientes tratados de DTM apresentam valores da atividade eletromiográfica durante a posição de repouso e durante a máxima intercuspidação habitual, distintos dos indivíduos assintomáticos; pacientes assintomáticos, tratados e portadores de DTM apresentam coeficientes de simetria muscular semelhantes tanto na posição de repouso quanto na máxima intercuspidação habitual / Abstract: This study was conducted to investigate the electromyographic activity values of the masseter and anterior temporalis muscles during rest and maximal intercuspal clenching, and the symmetry of the electromyographic activity of paired muscles, in 44 women, age range 18-40 years, with no history of bruxism. The patients were selected according pre-determined criteria, and were classified into three groups: asymptomatic (control group, n=14); TMD patients (TMD group, n=16); and TMD treated group (treated group, n=14). The electromyographic evaluations were performed using the K6-I/Emg Eight Channel Surface Electromyograph (Myotronics-Noromed Inc. Tukwila, WA). The data collected were compared using the Mann-Whitney U-test nonparametric analysis, and the results at rest showed EMG activity of masseter muscle in the control group significantly smaller than the TMD group and TMD-treated group; and EMG activity of anterior temporalis muscle at rest greater in the TMD compared to the TMD-treated group. The results of maximal clenching EMG activity of masseter muscle showed that the control group was significantly greater than the TMD group. The results at maximal intercuspal clenching showed EMG activity of masseter significantly greater in the control group than in the TMD group; and EMG activity of anterior temporalis muscle significantly greater in the control group than in the TMD group or TMD treated group. The symmetry of the electromyographic activity of paired muscles showed no differences among the groups nor at rest neither at maximal intercuspaI clenching. It was concluded that: asymptomatic subjects have the smallest electromyographic activity at rest and the greatest electromyographic activity at maximal intercuspal clenching; TMD patients have the greatest electromyographic activity at rest and the smallest electromyographic activity at maximal intercuspal clenching; TMD treated patients have different electromyographic pattems compared to asymptomatic subjects; The three groups have similar coefficient of symmetry in both masseter and anterior temporalis muscles / Doutorado / Protese Dental / Doutor em Clínica Odontológica
22

Avaliação do sinal eletromiográfico como parâmetro para determinação do limiar de fadiga muscular / Evaluation of the eletromyographic signal as paameter for determination of muscle fatigue threshold

Azevedo, Fábio Micolis de 01 October 2007 (has links)
Embora a analise no domínio da freqüência do sinal Eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada sua aplicação, especificamente a da Freqüência Mediana (Fmed), é pouco explorada para a determinação do Limiar de Fadiga Eletromiográfico (LFE). Neste estudo foram realizadas análises baseadas em procedimentos experimentais executados em três diferentes modalidades de exercício: i) isométrico; ii) isotônico com peso fixo; iii) isotônico no cicloergômetro; onde foi monitorado o comportamento da Fmed do sinal EMG em três porções do músculo quadríceps femoral: vasto lateral, vasto medial e reto femoral. Os resultados demonstraram ser possível determinar o LFE através da monitoração da Fmed, em qualquer modalidade de exercício para todas as três porções musculares avaliadas. Entretanto, para o exercício isométrico e isotônico com peso fixo a qualidade dos ajustes, utilizados para o calculo do LFE, apresentou melhores índices estatísticos em comparação com os resultados obtidos no cicloergômetro. Pode ser considerado um reflexo deste comportamento a menor variação nos valores do LFE observada nas duas primeiras modalidades de exercício. Por conseqüência, nestas modalidades, uma melhor caracterização do LFE, relacionada sua definição teórica, foi observada. A análise complementar das bandas de freqüência isoladas demonstrou a possibilidade de melhoramentos relacionados ao processo metodológico de tratamento do sinal EMG para determinação do LFE. Entende-se que a determinação do LFE é uma temática controversa, porém ao mesmo tempo apresenta um grande potencial de exploração científica caracterizando, neste contexto, a contribuição deste estudo para a área / Tthough the analysis in the frequency domain of the Electromyographic Signal (EMG) was used in the characterization of the localized muscular fatigue process their application, specifically the Median Frequency (MF), is rarely explored for the determination of Electromyographic Fatigue Threshold (EMGFT). In this study analysis based in experimental procedures were executed in three different modalities of exercise: i) isometric; ii) dynamic with fixed load; iii) dynamic in the cycle ergometer; where was monitored the behavior of the EMG signal through the MF in three portions of the quadriceps muscle: vastus lateralis, vastus medialis and rectus femoris. The results demonstrated that the determination of EMGFT through the monitorization of MF was possible, in any modality of exercises for all the three muscular portions evaluated. However for the isometric and dynamic exercise with fixed load the quality of the adjustments, used for estimate the EMGFT, presented better statistical index in comparison with the results obtained in the cycle ergometer. May be considered a reflex of this behavior the smallest variation in the values of EMGFT observed in the first two modalities of exercise. For consequence, in these modalities, a better characterization of EMGFT was observed when related with your theoretical definition. The complemental analysis of the isolated bands of frequency demonstrated the possibility of improvement related in the methodological process of EMG signal processing for determination of EMGFT. The understanding around the determination of EMGFT demonstrated a controversial theme, however at the same time it presents a great potential of scientific exploration characterizing, in this context, the contribution of present study for this area
23

Avaliação do sinal eletromiográfico como parâmetro para determinação do limiar de fadiga muscular / Evaluation of the eletromyographic signal as paameter for determination of muscle fatigue threshold

Fábio Micolis de Azevedo 01 October 2007 (has links)
Embora a analise no domínio da freqüência do sinal Eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada sua aplicação, especificamente a da Freqüência Mediana (Fmed), é pouco explorada para a determinação do Limiar de Fadiga Eletromiográfico (LFE). Neste estudo foram realizadas análises baseadas em procedimentos experimentais executados em três diferentes modalidades de exercício: i) isométrico; ii) isotônico com peso fixo; iii) isotônico no cicloergômetro; onde foi monitorado o comportamento da Fmed do sinal EMG em três porções do músculo quadríceps femoral: vasto lateral, vasto medial e reto femoral. Os resultados demonstraram ser possível determinar o LFE através da monitoração da Fmed, em qualquer modalidade de exercício para todas as três porções musculares avaliadas. Entretanto, para o exercício isométrico e isotônico com peso fixo a qualidade dos ajustes, utilizados para o calculo do LFE, apresentou melhores índices estatísticos em comparação com os resultados obtidos no cicloergômetro. Pode ser considerado um reflexo deste comportamento a menor variação nos valores do LFE observada nas duas primeiras modalidades de exercício. Por conseqüência, nestas modalidades, uma melhor caracterização do LFE, relacionada sua definição teórica, foi observada. A análise complementar das bandas de freqüência isoladas demonstrou a possibilidade de melhoramentos relacionados ao processo metodológico de tratamento do sinal EMG para determinação do LFE. Entende-se que a determinação do LFE é uma temática controversa, porém ao mesmo tempo apresenta um grande potencial de exploração científica caracterizando, neste contexto, a contribuição deste estudo para a área / Tthough the analysis in the frequency domain of the Electromyographic Signal (EMG) was used in the characterization of the localized muscular fatigue process their application, specifically the Median Frequency (MF), is rarely explored for the determination of Electromyographic Fatigue Threshold (EMGFT). In this study analysis based in experimental procedures were executed in three different modalities of exercise: i) isometric; ii) dynamic with fixed load; iii) dynamic in the cycle ergometer; where was monitored the behavior of the EMG signal through the MF in three portions of the quadriceps muscle: vastus lateralis, vastus medialis and rectus femoris. The results demonstrated that the determination of EMGFT through the monitorization of MF was possible, in any modality of exercises for all the three muscular portions evaluated. However for the isometric and dynamic exercise with fixed load the quality of the adjustments, used for estimate the EMGFT, presented better statistical index in comparison with the results obtained in the cycle ergometer. May be considered a reflex of this behavior the smallest variation in the values of EMGFT observed in the first two modalities of exercise. For consequence, in these modalities, a better characterization of EMGFT was observed when related with your theoretical definition. The complemental analysis of the isolated bands of frequency demonstrated the possibility of improvement related in the methodological process of EMG signal processing for determination of EMGFT. The understanding around the determination of EMGFT demonstrated a controversial theme, however at the same time it presents a great potential of scientific exploration characterizing, in this context, the contribution of present study for this area
24

Avaliação eletroneurográfica comparativa precoce de pacientes com plexopatia braquial obstétrica / Electroneurography for early prognostic assessment of obstetrical brachial plexopathy

Heise, Carlos Otto 01 October 2003 (has links)
O desenvolvimento de um método eficiente de avaliação prognóstica precoce seria de grande utilidade na seleção de lactentes com plexopatia braquial obstétrica para cirurgias de reconstrução do plexo braquial. Realizamos uma eletroneurografia bilateral em 33 bebês com plexopatia braquial obstétrica entre 10 e 60 dias de vida. Foram avaliadas e comparadas lado a lado as amplitudes dos potenciais de ação musculares compostos dos nervos axilar, musculocutâneo, radial proximal, radial distal, mediano e ulnar. Os bebês foram seguidos clinicamente até os seis meses de vida, quando foram submetidos a uma avaliação da força de vários grupos musculares e a uma prova funcional. Uma redução da amplitude do potencial de ação muscular composto em qualquer nervo do membro acometido maior ou igual a 90% da amplitude do potencial do membro sadio correlacionou-se com um resultado clínico ruim aos seis meses de idade (p < 0,01). A acurácia prognóstica da eletroneurografia foi de 91% para as lesões do tronco superior, 97% para as lesões do tronco médio e 100% para as lesões do tronco inferior. Nossos resultados indicam que a eletroneurografia parece ser um instrumento útil na avaliação prognóstica precoce de pacientes com plexopatia braquial obstétrica / Early prognostic assessment of obstetric brachial plexopathies would be a major step for rational selection of infants for brachial plexus surgery. We performed bilateral electroneurography of Axillary, Musculocutaneous, proximal Radial, distal Radial, Median and Ulnar nerves in 33 babies (age 10 - 60 days) with obstetrical brachial plexus lesions in order to compare the amplitude of compound muscle action potentials (CMAPs). The babies were followed up for six months and the outcome was classified according to muscle power score and functional performance. A CMAP amplitude reduction in any nerve of the injured side superior or equal to 90% of CMAP amplitude of the normal side was related to an unfavorable clinical result at age of six months (p < 0,01). The prognostic accuracy of electroneurography was 91% for the upper trunk, 97% for the middle trunk and 100% for the lower trunk. Our results indicate that electroneurography seems to be a useful tool for very early prognostic assessment of obstetric brachial plexopathies
25

Análise da fadiga muscular localizada em atletas e sedentários através de parâmetros de freqüência do sinal eletromiográfico / Analysis of localized muscle fatigue in athletes and sedentaries throught frequency parameters of electromyographic signal

Santos, Marcelo Cláudio Amaral [UNIFESP] 30 April 2008 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:49:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-04-30. Added 1 bitstream(s) on 2015-08-11T03:25:48Z : No. of bitstreams: 1 Publico-10870.pdf: 69580 bytes, checksum: 9aba33341c44980cac0fc8ab7561d008 (MD5) / Embora a análise no domínio da freqüência do sinal Eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada, sua aplicação, especificamente a da Freqüência Mediana (Fmed), é pouco explorada no âmbito esportivo. O objetivo do presente estudo foi verificar a viabilidade da aplicação do sinal EMG, através de sua análise no domínio da freqüência, como parâmetro para determinação e diferenciação no comportamento da fadiga muscular localizada. Dois grupos de sujeitos um caracterizado como atletas (n=12) e outro como sedentários (n=12), foram submetidos a análises baseadas em procedimentos executados em três diferentes situações experimentais, todos envolvendo a modalidade de exercício isométrico: i) teste máximo para determinação da Contração Isométrica Voluntária Máxima (CIVM); ii) teste de fadiga, sustentado por 35 seg. a 80% da CIVM; iii) teste de recuperação, sustentado por 10 seg. a 80% da CIVM; neste ultimo foi monitorado o comportamento da Fmed nos três primeiros (Fmedi) e três últimos segundos (Fmedf) do sinal EMG no músculo tibial anterior durante o teste de fadiga. Durante os 10 segundos do teste de recuperação foi calculada a Fmed referente a todo o período (Fmedr).parâmetro utilizado no cálculo do Índice de Recuperação Muscular (IRM). Os resultados apontam que a Fmedf apresentou valor menor em relação à Fmedi em ambos os grupos (p<0.05). Quando comparado ao grupo de sedentários, o grupo de atletas apresentou valores maiores de Fmedi e Fmedf (p<0.05). O valor médio e desvio padrão do IRM para o grupo de atletas foi de 62.1% ±28.7 e para o grupo de sedentários foi de 55.2% ±27.8 (p>0.05). Desta forma, os resultados apresentados neste estudo permitem inferir a viabilidade na aplicação de parâmetros no domínio da freqüência do sinal EMG para a determinação e diferenciação do comportamento da fadiga muscular localizada. / Though the analysis in the frequency domain of the Electromyographic Signal (EMG) was used in the characterization of the localized muscular fatigue process their application, specifically the Median Frequency (MF), is rarely explored in the sports. The objective of this study was to verify the viability in the application of the EMG signal, through of the frequency domain analysis, as parameter for determination and differentiation of the behavior of located muscle fatigue. Two groups of subjects one characterized as athletes (n=12) and other as sedentary (n=12), were submitted to analysis based in procedures executed in three different experimental situations, all involving the isometric exercise modality: i) maximum test for determination of the Maximum Voluntary Isometric Contraction (MVIC); ii) fatigue test, 35 sec. sustained load of 80% of MVIC; iii) recovery test, 10 sec. sustained load of 80% of MVIC; where was monitored the behavior of MF in the first three (Fmedi) and last three seconds (Fmedf) of the EMG signal of anterior tibial muscle during the fatigue test. During the 10 seconds of the recovery test MF was calculated regarding the whole period (Fmedr) this parameter was used to calculate the Recuperation Muscle Index (RMI). The results showed that Fmedf presented a low value in relation to Fmedi in both groups (p <0.05). Also the value of Fmedi and Fmedf for the athlete group presented larger higher value in comparison with the sedentary group (p <0.05). The mean value and standard deviation of RMI for the athlete group were 62.1% ±28.7 and for sedentary group was 55.2% ±27.8 (p>0.05). In general terms the results presented in this study allow inferring the viability in the application of the frequency domain parameters of the EMG signal for the determination and differentiation of the located muscle fatigue behavior. / TEDE / BV UNIFESP: Teses e dissertações
26

Avaliação eletroneurográfica comparativa precoce de pacientes com plexopatia braquial obstétrica / Electroneurography for early prognostic assessment of obstetrical brachial plexopathy

Carlos Otto Heise 01 October 2003 (has links)
O desenvolvimento de um método eficiente de avaliação prognóstica precoce seria de grande utilidade na seleção de lactentes com plexopatia braquial obstétrica para cirurgias de reconstrução do plexo braquial. Realizamos uma eletroneurografia bilateral em 33 bebês com plexopatia braquial obstétrica entre 10 e 60 dias de vida. Foram avaliadas e comparadas lado a lado as amplitudes dos potenciais de ação musculares compostos dos nervos axilar, musculocutâneo, radial proximal, radial distal, mediano e ulnar. Os bebês foram seguidos clinicamente até os seis meses de vida, quando foram submetidos a uma avaliação da força de vários grupos musculares e a uma prova funcional. Uma redução da amplitude do potencial de ação muscular composto em qualquer nervo do membro acometido maior ou igual a 90% da amplitude do potencial do membro sadio correlacionou-se com um resultado clínico ruim aos seis meses de idade (p < 0,01). A acurácia prognóstica da eletroneurografia foi de 91% para as lesões do tronco superior, 97% para as lesões do tronco médio e 100% para as lesões do tronco inferior. Nossos resultados indicam que a eletroneurografia parece ser um instrumento útil na avaliação prognóstica precoce de pacientes com plexopatia braquial obstétrica / Early prognostic assessment of obstetric brachial plexopathies would be a major step for rational selection of infants for brachial plexus surgery. We performed bilateral electroneurography of Axillary, Musculocutaneous, proximal Radial, distal Radial, Median and Ulnar nerves in 33 babies (age 10 - 60 days) with obstetrical brachial plexus lesions in order to compare the amplitude of compound muscle action potentials (CMAPs). The babies were followed up for six months and the outcome was classified according to muscle power score and functional performance. A CMAP amplitude reduction in any nerve of the injured side superior or equal to 90% of CMAP amplitude of the normal side was related to an unfavorable clinical result at age of six months (p < 0,01). The prognostic accuracy of electroneurography was 91% for the upper trunk, 97% for the middle trunk and 100% for the lower trunk. Our results indicate that electroneurography seems to be a useful tool for very early prognostic assessment of obstetric brachial plexopathies

Page generated in 0.0545 seconds