• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 14
  • 14
  • 12
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Estudo comparativo de diferentes métodos eletrocardiográficos de diagnóstico de hipertrofia ventricular esquerda e sua associação com característica anatômicas e histológicas do coração" / A comparative study of different electrocardiographic methods for the diagnosis of left ventricular hypertrophy and its association with both anatomic and histological characteristics of the heart

Ronconi, Júlio César 27 June 2005 (has links)
A hipertrofia ventricular esquerda (HVE) é importante fator de risco cardiovascular. O objetivo deste estudo retrospectivo foi verificar a associação de critérios eletrocardiográficos de HVE com as características anatômicas e histológicas do coração, em 51 pacientes submetidos à necropsia. Procedeu-se à medição do diâmetro transverso dos cardiomiócitos e da porcentagem de fibrose do ventrículo esquerdo e direito. Entre os pacientes que apresentavam HVE anatômica, o critério de Romhilt foi positivo em 92,3%, sendo superior aos demais critérios avaliados, com especificidade de 89,5% e sensibilidade de 68,8%, Foi o único que se associou a características anatômicas e histológicas do coração / The left ventricular hypertrophy (LVH) is an important cardiovascular risk factor. The purpose of the present retrospective paper is to examine the association of LVH electrocardiographic criteria with both anatomical and histological characteristics of the heart on 51 patients submitted to the necropsy. The study carried out the measurement of the transverse diameter of cardiomyocytes, as well as the percentage of fibrosis at both left and right ventriculi. Among those patients who presented anatomic LVH, the Romhilt criterium resulted positive in 92.3% of the cases, thus surpassing the other criteria evaluated, with specificity and sensibility up to 89.5% and 68.8% respectively. This was the only criterium associated to both anatomic and histological characteristics of the heart
2

"Estudo comparativo de diferentes métodos eletrocardiográficos de diagnóstico de hipertrofia ventricular esquerda e sua associação com característica anatômicas e histológicas do coração" / A comparative study of different electrocardiographic methods for the diagnosis of left ventricular hypertrophy and its association with both anatomic and histological characteristics of the heart

Júlio César Ronconi 27 June 2005 (has links)
A hipertrofia ventricular esquerda (HVE) é importante fator de risco cardiovascular. O objetivo deste estudo retrospectivo foi verificar a associação de critérios eletrocardiográficos de HVE com as características anatômicas e histológicas do coração, em 51 pacientes submetidos à necropsia. Procedeu-se à medição do diâmetro transverso dos cardiomiócitos e da porcentagem de fibrose do ventrículo esquerdo e direito. Entre os pacientes que apresentavam HVE anatômica, o critério de Romhilt foi positivo em 92,3%, sendo superior aos demais critérios avaliados, com especificidade de 89,5% e sensibilidade de 68,8%, Foi o único que se associou a características anatômicas e histológicas do coração / The left ventricular hypertrophy (LVH) is an important cardiovascular risk factor. The purpose of the present retrospective paper is to examine the association of LVH electrocardiographic criteria with both anatomical and histological characteristics of the heart on 51 patients submitted to the necropsy. The study carried out the measurement of the transverse diameter of cardiomyocytes, as well as the percentage of fibrosis at both left and right ventriculi. Among those patients who presented anatomic LVH, the Romhilt criterium resulted positive in 92.3% of the cases, thus surpassing the other criteria evaluated, with specificity and sensibility up to 89.5% and 68.8% respectively. This was the only criterium associated to both anatomic and histological characteristics of the heart
3

Estudo comparativo entre a avaliação livre, dirigida e automatizada na assistência ao diagnóstico eletrocardiográfico em crianças e adolescentes / Comparative study among the free evaluation, guided and automatized in the assistance to the electrocardiographic diagnosis in children and adolescents

Molina, Marcos Sleiman 30 July 2007 (has links)
No desenvolvimento cardíaco infantil, a mudança na dinâmica vetorial do miocárdio influencia os parâmetros de normalidade, especialmente nos primeiros dias de vida. Estes limites são idade-dependentes, o que torna a análise do eletrocardiograma (ECG) potencialmente mais difícil em crianças que em adultos. Para facilitar esta tarefa, desenvolvemos um sistema interpretativo computadorizado para análise segmentar no ECG pediátrico. Para validar esta ferramenta, 15 cardiologistas pediátricos foram randomicamente distribuídos em três diferentes grupos, segundo abordagem quali-quantitativa, aqui definidas como avaliação livre (AL), dirigida (AD) e automatizada (AA), na análise de 20 ECGs pediátricos, distribuídos em uma proporção mínima de 35% para exames anormais, com 16 segmentos estudados em cada ECG. Na AL, o cardiologista foi solicitado a responder se o segmento em análise estava normal ou não, com liberdade para medir cada segmento antes de responder. Na AD, a mesma pergunta foi formulada, porém com a imposição de uma aferição prévia do segmento em análise. Consultar a tabela de normalidade foi permitida em ambas situações. Na AA, apenas a aferição foi solicitada e o resultado submetido a um software de interpretação segmentar para ECG pediátrico, com a tabela de normalidade em seu banco de dados. As respostas foram comparadas às análises de dois cardiologistas controle e os resultados conflitantes foram considerados discordantes. Foram observadas discordâncias em 11,6%, 10,7% e 6,2% nas AL, AD e AA, respectivamente. O viés de interpretação foi reduzido em 45% (p<0,0001) com o uso da AA. Observou-se maior benefício com a AA nos estudos das ondas Q em avF e em V6 e R em V1. Em análises não automatizadas, a aferição precedente não mudou a avaliação segmentar do ECG. Concluindo, a AA reduziu significativamente o viés interpretativo em análises não automatizadas, a aferição precedente não mudou a interpretação do ECG e o uso deste software permitiu reduzir o erro de análise segmentar em 45%. / During the cardiac development of children, changes in the vectorial dynamics of the myocardium influence upon normality standards, especially during the first days in life. These are age-dependent limits that make the analysis of EKG of children potentially harder than that of adults. Aiming to make this task easier, we designed a computerized interpretation system for segmental analysis of pediatric EKGs. In order to validate this tool, 15 pediatric cardiologists were randomly allocated to three different groups according to qualitative-quantitative evaluation methods herein defined as free (FE), guided (GE) and automatized (AE) evaluation, for the purpose of analyzing 20 pediatric EKG tracings distributed in a proportion of at least 35% abnormal examinations, with 16 segments being studied in each EKG tracing. In FE, cardiologists were asked to answer whether the segment was normal or not, with freedom to measure each segment before giving their answer. In GE, the same question was made, however they were requested to measure the segment before answering. In both situations they were allowed to refer to a table of normality standards. In AE, only the measurement was asked, and the result was then entered into the software for segmental interpretation of pediatric EKGs, whose database included the table of normality standards. Answers were all compared with those given by two control cardiologists. Discordant results were seen in 11.6%, 10.7% and 6.2% of FE, GE and AE, respectively. Interpretation bias was reduced by 45% (p<0.0001) with the use of AE. In the not automatized types of analyses, previous measurement of segments did not alter the segmental evaluation of EKGs . In conclusion, the automatized evaluation significantly reduced interpretation bias, previous measurement did not change the EKG interpretation with the other not automatized methods and the use of this software allowed to reduce the error of segmental analysis in 45%.
4

Aquisição eletrocardiográfica em equinos: definindo uma nova e mais adequada metodologia para a espécie / Equine electrocardiographic acquisition: defining a new and most adequate methodology for the species

Costa, Cássia Fré da 05 December 2017 (has links)
INTRODUÇÃO: Vários sistemas de derivações eletrocardiográficas são utilizados na espécie equina e os principais incluem o método de Einthoven, o Ápice-base e o Dubois. O intuito desses sistemas é de captar ondas e complexos de modo que o processo de condução elétrica seja avaliado de maneira eficaz. A disposição dos eletrodos pela metodologia de Dubois tenta posicionar o coração do equino no meio de um triângulo virtual dentro do tórax, assim como descrito por Einthoven, que se baseou no modelo humano. Entretanto, ao se fazer um paralelo com o posicionamento desses eletrodos no ser humano é possível verificar que, apesar da centralização do coração do equino no triangulo virtual, as referências de direita e de esquerda não são respeitadas. Este fato é explicado pela relação entre o ventrículo direito e o ventrículo esquerdo, que nos equinos e outros animais domésticos (na maioria quadrúpedes) se faz no sentido crânio-caudal, enquanto que a posição do coração dentro do tórax do ser humano (bípede) é predominantemente no sentido ântero-súpero-póstero-inferior. OBJETIVOS: O objetivo primário desta tese é o estabelecimento de uma nova e mais adequada metodologia de aquisição eletrocardiográfica para a espécie equina e o objetivo secundário é usar as medidas das variáveis eletrocardiográficas aqui encontradas como valores de referência para essa espécie. MATERIAIS E MÉTODOS: Foram utilizados 22 cavalos da raça Puro Sangue Inglês, sendo 11 fêmeas e 11 machos, com idades variando entre 2 e 5 anos, residentes do Jockey Club de São Paulo, Brasil. Foram realizados 2 eletrocardiogramas sequenciais em cada animal, sendo o primeiro pelo método de Dubois e o segundo de acordo com a nova metodologia aqui instituída, a qual foi nomeada de método Fré. Foi realizado ecocardiograma prévio em todos os equinos e estudo Holter em quatro animais do experimento, os quais foram submetidos à análise de TWA. RESULTADOS: Pelo eletrocardiograma, foi constatado que as derivações esquerdas do plano frontal (DI e aVL) apresentaram complexo QRS de maior duração e amplitude pela nova metodologia e o inverso ocorreu nas derivações inferiores (DII, DIII e aVF), com p < 0,0001. CONCLUSÃO: O método Fré proposto neste estudo mostrou ser mais adequado, quando comparado ao método de Dubois, na obtenção dos fenômenos elétricos cardíacos que ocorrem nos animais da espécie equina. As medidas eletrocardiográficas obtidas pelo método Fré podem ser usados como referência de valores normais para a espécie equina / INTRODUCTION: Many electrocardiographic methods are used for the equine species, among which the most used include Einthoven, Base-apex and Dubois lead systems. They aim to capture waves and complexes to evaluate the process of electric heart conduction in the most effective way. Placement of the electrodes by the Dubois lead system attempts to position the equine heart at the center of a virtual triangle inside the animal\'s thorax, as described by Einthoven, who based his system on the human model. However, in attempting to make a parallel with the positioning of electrodes in the human torso, it is possible to find out that, despite the centralization of the equine heart inside the virtual triangle, the references of right and left are not respected. This can be explained by the relationship between the right and left ventricles, which in the equines and pets (mostly quadrupeds) is done in the cranio-caudal direction, while the position of the heart inside the human thorax (biped) determines that this relationship is predominantly in the anterior-superior-posterior-inferior direction. OBJECTIVES: The primary objective of this thesis is the establishment of a new and most suitable methodology of electrocardiographic acquisition in equines and the secondary objective is the establishment of the electrocardiographic variables thus obtained as reference for this species. MATERIALS AND METHODS: Twenty-two Thoroughbred horses were used, 11 females and 11 males, aged 2 to 5 years old, all reared at the São Paulo Jockey Club, Brazil. Two sequential electrocardiograms were recorded from each animal, the first according to the Dubois lead system and the second according to the new methodology here suggested, which was denominated Fré lead system. All the horses had a previous echocardiogram recorded, in addition to a Holter-ECG obtained from four animals of this experiment, which were subjected to TWA analysis. RESULTS: Through the electrocardiogram it was observed that the values obtained in the left leads of the frontal plane (DI and aVL) showed a larger and taller QRS complex by the new methodology, the reverse happening with the inferior leads such as DII, DIII and aVF, with p < 0,0001. CONCLUSION: The Fré lead system proposed here is more suitable when compared to the Dubois lead system to acquire the cardiac electric phenomena in equines. Electrocardiographic measurements obtained by the Fré lead system can be used as normal reference values for equines
5

Avaliação da dose de radiação: angiotomografia coronariana - métodos retrospectivo e prospectivo

Braghini, André Luís 28 May 2015 (has links)
O objetivo deste estudo foi avaliar a dose efetiva de radiação nos exames de CCTA através dos métodos Prospectivo e Retrospectivo do ECG. A coleta de dados foi realizada na Clínica Sabedotti, em Ponta Grossa – PR, em um equipamento General Electric modelo VCT XT, de 64 linhas de detecção. A dose efetiva foi mensurada para 30 casos, selecionados aleatoriamente do Picture Archival and Communication System – PACS, Arquivamento e Comunicação de Imagens, a partir do Produto Dose Comprimento (DLP) reportado pelo equipamento para cada exame e pelo fator de conversão (EDLP) definido pela Comissão Europeia para região cardíaca (EDLP = 0,014). Os resultados apontaram diferenças expressivas quanto à dose de radiação entregue ao paciente de acordo com o método de aquisição empregado, Retrospectivo ou Prospectivo do ECG. / The aim of this study was to evaluate the effective dose received by patients undergoing CCTA in both acquisition methods in the period June 1st to October 30th, 2013. Data collection was performed at the Clínica Sabedotti in Ponta Grossa/PR, with General Electric Equipment VCT XT, 64 detections lines. The effective dose was measured from the thirty cases randomly selected of Picture Archival and Communication System – PACS, reported by Dose Lenght Product (DLP) equipment for each examination and the conversion factor (EDLP) set by the European Commission for cardiac region (EDLP = 0.014). The results showed significant differences in radiation dose delivered to the patient according to the employee acquisition method, Retrospective or Prospective of ECG.
6

Avaliação da dose de radiação: angiotomografia coronariana - métodos retrospectivo e prospectivo

Braghini, André Luís 28 May 2015 (has links)
O objetivo deste estudo foi avaliar a dose efetiva de radiação nos exames de CCTA através dos métodos Prospectivo e Retrospectivo do ECG. A coleta de dados foi realizada na Clínica Sabedotti, em Ponta Grossa – PR, em um equipamento General Electric modelo VCT XT, de 64 linhas de detecção. A dose efetiva foi mensurada para 30 casos, selecionados aleatoriamente do Picture Archival and Communication System – PACS, Arquivamento e Comunicação de Imagens, a partir do Produto Dose Comprimento (DLP) reportado pelo equipamento para cada exame e pelo fator de conversão (EDLP) definido pela Comissão Europeia para região cardíaca (EDLP = 0,014). Os resultados apontaram diferenças expressivas quanto à dose de radiação entregue ao paciente de acordo com o método de aquisição empregado, Retrospectivo ou Prospectivo do ECG. / The aim of this study was to evaluate the effective dose received by patients undergoing CCTA in both acquisition methods in the period June 1st to October 30th, 2013. Data collection was performed at the Clínica Sabedotti in Ponta Grossa/PR, with General Electric Equipment VCT XT, 64 detections lines. The effective dose was measured from the thirty cases randomly selected of Picture Archival and Communication System – PACS, reported by Dose Lenght Product (DLP) equipment for each examination and the conversion factor (EDLP) set by the European Commission for cardiac region (EDLP = 0.014). The results showed significant differences in radiation dose delivered to the patient according to the employee acquisition method, Retrospective or Prospective of ECG.
7

Aquisição eletrocardiográfica em equinos: definindo uma nova e mais adequada metodologia para a espécie / Equine electrocardiographic acquisition: defining a new and most adequate methodology for the species

Cássia Fré da Costa 05 December 2017 (has links)
INTRODUÇÃO: Vários sistemas de derivações eletrocardiográficas são utilizados na espécie equina e os principais incluem o método de Einthoven, o Ápice-base e o Dubois. O intuito desses sistemas é de captar ondas e complexos de modo que o processo de condução elétrica seja avaliado de maneira eficaz. A disposição dos eletrodos pela metodologia de Dubois tenta posicionar o coração do equino no meio de um triângulo virtual dentro do tórax, assim como descrito por Einthoven, que se baseou no modelo humano. Entretanto, ao se fazer um paralelo com o posicionamento desses eletrodos no ser humano é possível verificar que, apesar da centralização do coração do equino no triangulo virtual, as referências de direita e de esquerda não são respeitadas. Este fato é explicado pela relação entre o ventrículo direito e o ventrículo esquerdo, que nos equinos e outros animais domésticos (na maioria quadrúpedes) se faz no sentido crânio-caudal, enquanto que a posição do coração dentro do tórax do ser humano (bípede) é predominantemente no sentido ântero-súpero-póstero-inferior. OBJETIVOS: O objetivo primário desta tese é o estabelecimento de uma nova e mais adequada metodologia de aquisição eletrocardiográfica para a espécie equina e o objetivo secundário é usar as medidas das variáveis eletrocardiográficas aqui encontradas como valores de referência para essa espécie. MATERIAIS E MÉTODOS: Foram utilizados 22 cavalos da raça Puro Sangue Inglês, sendo 11 fêmeas e 11 machos, com idades variando entre 2 e 5 anos, residentes do Jockey Club de São Paulo, Brasil. Foram realizados 2 eletrocardiogramas sequenciais em cada animal, sendo o primeiro pelo método de Dubois e o segundo de acordo com a nova metodologia aqui instituída, a qual foi nomeada de método Fré. Foi realizado ecocardiograma prévio em todos os equinos e estudo Holter em quatro animais do experimento, os quais foram submetidos à análise de TWA. RESULTADOS: Pelo eletrocardiograma, foi constatado que as derivações esquerdas do plano frontal (DI e aVL) apresentaram complexo QRS de maior duração e amplitude pela nova metodologia e o inverso ocorreu nas derivações inferiores (DII, DIII e aVF), com p < 0,0001. CONCLUSÃO: O método Fré proposto neste estudo mostrou ser mais adequado, quando comparado ao método de Dubois, na obtenção dos fenômenos elétricos cardíacos que ocorrem nos animais da espécie equina. As medidas eletrocardiográficas obtidas pelo método Fré podem ser usados como referência de valores normais para a espécie equina / INTRODUCTION: Many electrocardiographic methods are used for the equine species, among which the most used include Einthoven, Base-apex and Dubois lead systems. They aim to capture waves and complexes to evaluate the process of electric heart conduction in the most effective way. Placement of the electrodes by the Dubois lead system attempts to position the equine heart at the center of a virtual triangle inside the animal\'s thorax, as described by Einthoven, who based his system on the human model. However, in attempting to make a parallel with the positioning of electrodes in the human torso, it is possible to find out that, despite the centralization of the equine heart inside the virtual triangle, the references of right and left are not respected. This can be explained by the relationship between the right and left ventricles, which in the equines and pets (mostly quadrupeds) is done in the cranio-caudal direction, while the position of the heart inside the human thorax (biped) determines that this relationship is predominantly in the anterior-superior-posterior-inferior direction. OBJECTIVES: The primary objective of this thesis is the establishment of a new and most suitable methodology of electrocardiographic acquisition in equines and the secondary objective is the establishment of the electrocardiographic variables thus obtained as reference for this species. MATERIALS AND METHODS: Twenty-two Thoroughbred horses were used, 11 females and 11 males, aged 2 to 5 years old, all reared at the São Paulo Jockey Club, Brazil. Two sequential electrocardiograms were recorded from each animal, the first according to the Dubois lead system and the second according to the new methodology here suggested, which was denominated Fré lead system. All the horses had a previous echocardiogram recorded, in addition to a Holter-ECG obtained from four animals of this experiment, which were subjected to TWA analysis. RESULTS: Through the electrocardiogram it was observed that the values obtained in the left leads of the frontal plane (DI and aVL) showed a larger and taller QRS complex by the new methodology, the reverse happening with the inferior leads such as DII, DIII and aVF, with p < 0,0001. CONCLUSION: The Fré lead system proposed here is more suitable when compared to the Dubois lead system to acquire the cardiac electric phenomena in equines. Electrocardiographic measurements obtained by the Fré lead system can be used as normal reference values for equines
8

Estudo comparativo entre a avaliação livre, dirigida e automatizada na assistência ao diagnóstico eletrocardiográfico em crianças e adolescentes / Comparative study among the free evaluation, guided and automatized in the assistance to the electrocardiographic diagnosis in children and adolescents

Marcos Sleiman Molina 30 July 2007 (has links)
No desenvolvimento cardíaco infantil, a mudança na dinâmica vetorial do miocárdio influencia os parâmetros de normalidade, especialmente nos primeiros dias de vida. Estes limites são idade-dependentes, o que torna a análise do eletrocardiograma (ECG) potencialmente mais difícil em crianças que em adultos. Para facilitar esta tarefa, desenvolvemos um sistema interpretativo computadorizado para análise segmentar no ECG pediátrico. Para validar esta ferramenta, 15 cardiologistas pediátricos foram randomicamente distribuídos em três diferentes grupos, segundo abordagem quali-quantitativa, aqui definidas como avaliação livre (AL), dirigida (AD) e automatizada (AA), na análise de 20 ECGs pediátricos, distribuídos em uma proporção mínima de 35% para exames anormais, com 16 segmentos estudados em cada ECG. Na AL, o cardiologista foi solicitado a responder se o segmento em análise estava normal ou não, com liberdade para medir cada segmento antes de responder. Na AD, a mesma pergunta foi formulada, porém com a imposição de uma aferição prévia do segmento em análise. Consultar a tabela de normalidade foi permitida em ambas situações. Na AA, apenas a aferição foi solicitada e o resultado submetido a um software de interpretação segmentar para ECG pediátrico, com a tabela de normalidade em seu banco de dados. As respostas foram comparadas às análises de dois cardiologistas controle e os resultados conflitantes foram considerados discordantes. Foram observadas discordâncias em 11,6%, 10,7% e 6,2% nas AL, AD e AA, respectivamente. O viés de interpretação foi reduzido em 45% (p<0,0001) com o uso da AA. Observou-se maior benefício com a AA nos estudos das ondas Q em avF e em V6 e R em V1. Em análises não automatizadas, a aferição precedente não mudou a avaliação segmentar do ECG. Concluindo, a AA reduziu significativamente o viés interpretativo em análises não automatizadas, a aferição precedente não mudou a interpretação do ECG e o uso deste software permitiu reduzir o erro de análise segmentar em 45%. / During the cardiac development of children, changes in the vectorial dynamics of the myocardium influence upon normality standards, especially during the first days in life. These are age-dependent limits that make the analysis of EKG of children potentially harder than that of adults. Aiming to make this task easier, we designed a computerized interpretation system for segmental analysis of pediatric EKGs. In order to validate this tool, 15 pediatric cardiologists were randomly allocated to three different groups according to qualitative-quantitative evaluation methods herein defined as free (FE), guided (GE) and automatized (AE) evaluation, for the purpose of analyzing 20 pediatric EKG tracings distributed in a proportion of at least 35% abnormal examinations, with 16 segments being studied in each EKG tracing. In FE, cardiologists were asked to answer whether the segment was normal or not, with freedom to measure each segment before giving their answer. In GE, the same question was made, however they were requested to measure the segment before answering. In both situations they were allowed to refer to a table of normality standards. In AE, only the measurement was asked, and the result was then entered into the software for segmental interpretation of pediatric EKGs, whose database included the table of normality standards. Answers were all compared with those given by two control cardiologists. Discordant results were seen in 11.6%, 10.7% and 6.2% of FE, GE and AE, respectively. Interpretation bias was reduced by 45% (p<0.0001) with the use of AE. In the not automatized types of analyses, previous measurement of segments did not alter the segmental evaluation of EKGs . In conclusion, the automatized evaluation significantly reduced interpretation bias, previous measurement did not change the EKG interpretation with the other not automatized methods and the use of this software allowed to reduce the error of segmental analysis in 45%.
9

O eletrocardiograma de alta resolução no domínio do tempo em portadores de insuficiência cardíaca congestiva / The signal-averaged electrocardiogram in pacients with congestive heart failure

Grell, Ernani de Sousa 20 February 2003 (has links)
Foi avaliada a incidência de potencial tardio pelo eletrocardiograma de alta resolução no domínio do tempo em portadores de insuficiência cardíaca congestiva de diferentes etiologias com o objetivo de se estudarem as correlações clínicas e prognósticas entre pacientes com potencial tardio presente e ausente na referida patologia. Foram estudados 288 pacientes com insuficiência cardíaca congestiva, de idades entre 16 a 70 anos (média 51,51; desvio padrão 11,24), 215 do sexo masculino (74,65%) e 73 do sexo feminino (25,35%). As etiologias da insuficiência cardíaca congestiva foram: a cardiopatia hipertensiva em 78 pacientes (27,08%); a cardiopatia isquêmica em 65 (22,57%); a Doença de Chagas em 42 (14,58%); a valvopatia em 12 (4,17%); a cardiomiopatia alcoólica em 9 (3,13%); a cardiomiopatia periparto em 6 (2,08%); a miocardite viral em 3 (1,04%). Em 73 pacientes (25,35%), a etiologia não foi identificada e a cardiomiopatia dilatada foi considerada idiopática. Foram estudados a idade, o sexo, a etiologia da insuficiência cardíaca, as variáveis do eletrocardiograma (área eletricamente inativa e bloqueios de ramo), do ecocardiograma transtorácico (diâmetro do átrio esquerdo, diâmetro sistólico e diastólico do ventrículo esquerdo), da ergoespirometria (consumo máximo de oxigênio) e do eletrocardiograma de longa duração (taquicardia ventricular não sustentada e taquicardia ventricular sustentada). No eletrocardiograma de alta resolução, foram estudadas a duração do QRS standard, a duração do QRS filtrado, a duração do sinal abaixo de 40µV e a voltagem da raiz quadrada dos últimos 40ms. Foi considerado o potencial tardio presente na vigência de dois ou mais dos seguintes critérios: Duração do QRS filtrado >= 114ms; duração do sinal abaixo de 40µV >= 38ms; voltagem da raiz quadrada dos últimos 40ms <= 20µV. Para a análise estatística, foram empregados: o teste de Fisher, para o caso de comparações entre duas variáveis categóricas com 2 categorias cada uma; o teste t-Student, para o caso de comparações entre as médias dos dois grupos para variáveis contínuas; o teste de Man-Whitney (não paramétrico), para o caso de comparações entre os dois grupos quando as variáveis eram provenientes de contagens (número de ocorrências); ANOVA (análise de variância), para o caso de comparações entre mais de dois grupos no caso de variáveis contínuas. Não se observou correlação estatística entre a presença de potencial tardio e as etiologias que levaram à insuficiência cardíaca. Houve correlação entre a duração do QRS standard e a duração do QRS filtrado com a Doença de Chagas e a cardiomiopatia dilatada idiopática. O potencial tardio mostrou correlação significativa com: bloqueios de ramo, duração do QRS maior ou igual a 120ms, consumo máximo de oxigênio, taquicardia ventricular não sustentada, taquicardia ventricular sustentada, morte súbita e mortalidade total. Ao correlacionarmos a presença de potencial tardio com uma má evolução (taquicardia ventricular sustentada, morte súbita e morte por evolução da insuficiência cardíaca) e uma boa evolução (nenhuma das complicações anteriores), foi encontrado diferença significativa no grupo que apresentava potencial tardio presente. Concluímos que pacientes com insuficiência cardíaca congestiva e portadores de potencial tardio presente ao eletrocardiograma de alta resolução têm achado estatisticamente significativo quanto à taquicardia ventricular sustentada e à morte súbita e uma má evolução em relação aos pacientes com potencial tardio ausente. / The incidence of late potential was evaluated by the signal-averaged electrocardiogram in the time domain in patients with congestive heart failure of different etiologies with the goal of studying the clinical and prognostic correlation among patients with the presence and the absence of late potential in the related pathology. 288 patients with congestive heart failure were studied, from 16 to 70 years old (average 51,51; standard deviation 11,24), 215 of males (74.65%) and 73 of females (25.35%). The etiologies of the congestive heart failure were: the hypertensive cardiomyopathy in 78 patients (27.08%); the ischemic cardiomyopathy in 65 (22.57%); the Chagas disease in 42 (14.58%); the valvopathy in 12 (4.17%); the alcoholic heart disease in 9 (3.13%); the delivery cardiomyopathy in 6 (2.08%); the viral myocarditis in 3 (1.04%). In 73 patients (25.35%); the etiology was not identified and the dilated cardiomyopathy was considered idiopathic. The age, sex, and etiology of the cardiac failure, the variable of the electrocardiogram (electric inactive area and bundle branch block), of the transthoracic echocardiogram (left atrium diameter, systolic and diastolic diameter of the left ventricle), of the cardiopulmonary exercise test (maximum consumption of oxygen) and of the Holter monitoring (nonsustained ventricular tachycardia and ventricular tachycardia) have been studied. In the signal-averaged electrocardiogram, the standard QRS duration, the filtered QRS duration, the filtered QRS complex below 40µV and the root mean square voltage of the terminal 40ms were studied. The late potential was considered in the existance of two or more of the following criteria: the filtered QRS duration >= 114ms; the filtered QRS complex bellow 40µV >= 38ms; the root mean square voltage of the terminal 40ms <= 20µV. For the statistic analysis, the Fisher test was used for the case of comparison between two specific variables, each one with 2 categories; the test t-Student was used for the case of comparison between the average of the two groups for continuous variables; the Man-Whitney test, for the case of comparison between the two groups when the variables were proceeding from counting (number of occurrences); the ANOVA (variance analysis), for the case of contrast between more than two groups in the case of continuous variables. Statistic correlation was not observed in the presence of late potential and the etiologies that had to the heart failure. There was correlation between the standard QRS duration and the filtered QRS duration with the Chagas disease and the idiopathic dilated cardiomyopathy. The late potential showed remarkable correlation with bundle branch block, duration of the largest or equal to 120ms QRS, maximum consumption of oxygen, nonsustained ventricular tachycardia, sustained ventricular tachycardia, sudden death and total mortality. When correlating the presence of late potential with a bad evolution (sustained ventricular tachycardia, sudden death and death by evolution of the heart failure) and a good evolution (none of the previous complications), relevant difference was found in the group that presented late potential. To conclude, patients with congestive heart failure and carrying late potential shown by the signal-averaged electrocardiogram have statistically relevant findings in the sustained ventricular tachycardia and the sudden death and a bad evolution in relation to the patients with absent late potential.
10

O eletrocardiograma de alta resolução no domínio do tempo em portadores de insuficiência cardíaca congestiva / The signal-averaged electrocardiogram in pacients with congestive heart failure

Ernani de Sousa Grell 20 February 2003 (has links)
Foi avaliada a incidência de potencial tardio pelo eletrocardiograma de alta resolução no domínio do tempo em portadores de insuficiência cardíaca congestiva de diferentes etiologias com o objetivo de se estudarem as correlações clínicas e prognósticas entre pacientes com potencial tardio presente e ausente na referida patologia. Foram estudados 288 pacientes com insuficiência cardíaca congestiva, de idades entre 16 a 70 anos (média 51,51; desvio padrão 11,24), 215 do sexo masculino (74,65%) e 73 do sexo feminino (25,35%). As etiologias da insuficiência cardíaca congestiva foram: a cardiopatia hipertensiva em 78 pacientes (27,08%); a cardiopatia isquêmica em 65 (22,57%); a Doença de Chagas em 42 (14,58%); a valvopatia em 12 (4,17%); a cardiomiopatia alcoólica em 9 (3,13%); a cardiomiopatia periparto em 6 (2,08%); a miocardite viral em 3 (1,04%). Em 73 pacientes (25,35%), a etiologia não foi identificada e a cardiomiopatia dilatada foi considerada idiopática. Foram estudados a idade, o sexo, a etiologia da insuficiência cardíaca, as variáveis do eletrocardiograma (área eletricamente inativa e bloqueios de ramo), do ecocardiograma transtorácico (diâmetro do átrio esquerdo, diâmetro sistólico e diastólico do ventrículo esquerdo), da ergoespirometria (consumo máximo de oxigênio) e do eletrocardiograma de longa duração (taquicardia ventricular não sustentada e taquicardia ventricular sustentada). No eletrocardiograma de alta resolução, foram estudadas a duração do QRS standard, a duração do QRS filtrado, a duração do sinal abaixo de 40µV e a voltagem da raiz quadrada dos últimos 40ms. Foi considerado o potencial tardio presente na vigência de dois ou mais dos seguintes critérios: Duração do QRS filtrado >= 114ms; duração do sinal abaixo de 40µV >= 38ms; voltagem da raiz quadrada dos últimos 40ms <= 20µV. Para a análise estatística, foram empregados: o teste de Fisher, para o caso de comparações entre duas variáveis categóricas com 2 categorias cada uma; o teste t-Student, para o caso de comparações entre as médias dos dois grupos para variáveis contínuas; o teste de Man-Whitney (não paramétrico), para o caso de comparações entre os dois grupos quando as variáveis eram provenientes de contagens (número de ocorrências); ANOVA (análise de variância), para o caso de comparações entre mais de dois grupos no caso de variáveis contínuas. Não se observou correlação estatística entre a presença de potencial tardio e as etiologias que levaram à insuficiência cardíaca. Houve correlação entre a duração do QRS standard e a duração do QRS filtrado com a Doença de Chagas e a cardiomiopatia dilatada idiopática. O potencial tardio mostrou correlação significativa com: bloqueios de ramo, duração do QRS maior ou igual a 120ms, consumo máximo de oxigênio, taquicardia ventricular não sustentada, taquicardia ventricular sustentada, morte súbita e mortalidade total. Ao correlacionarmos a presença de potencial tardio com uma má evolução (taquicardia ventricular sustentada, morte súbita e morte por evolução da insuficiência cardíaca) e uma boa evolução (nenhuma das complicações anteriores), foi encontrado diferença significativa no grupo que apresentava potencial tardio presente. Concluímos que pacientes com insuficiência cardíaca congestiva e portadores de potencial tardio presente ao eletrocardiograma de alta resolução têm achado estatisticamente significativo quanto à taquicardia ventricular sustentada e à morte súbita e uma má evolução em relação aos pacientes com potencial tardio ausente. / The incidence of late potential was evaluated by the signal-averaged electrocardiogram in the time domain in patients with congestive heart failure of different etiologies with the goal of studying the clinical and prognostic correlation among patients with the presence and the absence of late potential in the related pathology. 288 patients with congestive heart failure were studied, from 16 to 70 years old (average 51,51; standard deviation 11,24), 215 of males (74.65%) and 73 of females (25.35%). The etiologies of the congestive heart failure were: the hypertensive cardiomyopathy in 78 patients (27.08%); the ischemic cardiomyopathy in 65 (22.57%); the Chagas disease in 42 (14.58%); the valvopathy in 12 (4.17%); the alcoholic heart disease in 9 (3.13%); the delivery cardiomyopathy in 6 (2.08%); the viral myocarditis in 3 (1.04%). In 73 patients (25.35%); the etiology was not identified and the dilated cardiomyopathy was considered idiopathic. The age, sex, and etiology of the cardiac failure, the variable of the electrocardiogram (electric inactive area and bundle branch block), of the transthoracic echocardiogram (left atrium diameter, systolic and diastolic diameter of the left ventricle), of the cardiopulmonary exercise test (maximum consumption of oxygen) and of the Holter monitoring (nonsustained ventricular tachycardia and ventricular tachycardia) have been studied. In the signal-averaged electrocardiogram, the standard QRS duration, the filtered QRS duration, the filtered QRS complex below 40µV and the root mean square voltage of the terminal 40ms were studied. The late potential was considered in the existance of two or more of the following criteria: the filtered QRS duration >= 114ms; the filtered QRS complex bellow 40µV >= 38ms; the root mean square voltage of the terminal 40ms <= 20µV. For the statistic analysis, the Fisher test was used for the case of comparison between two specific variables, each one with 2 categories; the test t-Student was used for the case of comparison between the average of the two groups for continuous variables; the Man-Whitney test, for the case of comparison between the two groups when the variables were proceeding from counting (number of occurrences); the ANOVA (variance analysis), for the case of contrast between more than two groups in the case of continuous variables. Statistic correlation was not observed in the presence of late potential and the etiologies that had to the heart failure. There was correlation between the standard QRS duration and the filtered QRS duration with the Chagas disease and the idiopathic dilated cardiomyopathy. The late potential showed remarkable correlation with bundle branch block, duration of the largest or equal to 120ms QRS, maximum consumption of oxygen, nonsustained ventricular tachycardia, sustained ventricular tachycardia, sudden death and total mortality. When correlating the presence of late potential with a bad evolution (sustained ventricular tachycardia, sudden death and death by evolution of the heart failure) and a good evolution (none of the previous complications), relevant difference was found in the group that presented late potential. To conclude, patients with congestive heart failure and carrying late potential shown by the signal-averaged electrocardiogram have statistically relevant findings in the sustained ventricular tachycardia and the sudden death and a bad evolution in relation to the patients with absent late potential.

Page generated in 0.0844 seconds