Spelling suggestions: "subject:"endosseous"" "subject:"endoosseous""
31 |
Dental implants evaluated by periapical and panoramic radiography a thesis submitted in partial fulfillment ... oral diagnosis and radiology ... /Halk, Gerald J. January 1988 (has links)
Thesis (M.S.)--University of Michigan, 1988.
|
32 |
Histomorphometric and radiopharmaceutical investigations of the bone integration of implants in vivo laboratory models /McCracken, Michael January 1999 (has links)
Thesis (Ph. D.)--University of Alabama at Birmingham, 1999. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
33 |
Regeneration in periodontal and endosseous implant treatmentMayfield, Lisa. January 1998 (has links)
Thesis (doctoral)--Lunds Universitet, Malmö, 1998. / Added t.p. and errata sheet inserted. Includes bibliographical references.
|
34 |
Histomorphometric and radiopharmaceutical investigations of the bone integration of implants in vivo laboratory models /McCracken, Michael January 1999 (has links)
Thesis (Ph. D.)--University of Alabama at Birmingham, 1999. / Includes bibliographical references.
|
35 |
Avaliação clínica e da freqüência de ressonância, de implantes instalados por meio de técnica cirúrgica modificada na maxila e submetidos à função imediataVasconcelos, Laércio Wonhrath [UNESP] 03 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-02-03Bitstream added on 2014-06-13T19:43:11Z : No. of bitstreams: 1
vasconcelos_lw_dr_araca.pdf: 3387652 bytes, checksum: 665ddeee618bbda24e7caff661ab090e (MD5) / Universidade Estadual Paulista (UNESP) / Brånemark et al. (1969) introduziram os implantes osseointegrados como forma de ancoragem para próteses com intuito de substituir os dentes perdidos, tanto na mandíbula como na maxila. Desde então, foram instituídas modificações no protocolo clássico. Entre elas, a submissão dos implantes à função imediatamente após a sua instalação. Esse procedimento tem sido largamente estudado na mandíbula, com altos índices de sucesso, contudo, a literatura é escassa quanto à aplicação desta técnica na maxila. Propôs-se, então, avaliar a função imediata em implantes instalados em maxilas desdentadas totais, no momento da cirurgia e após seis e 12 meses de função. Para tanto foi utilizada uma técnica cirúrgica modificada e a avaliação da estabilidade dos implantes foi feita por meio da análise da freqüência de ressonância. Foram selecionados 10 pacientes, nos quais foram instalados seis implantes na maxila com a submissão dos mesmos à função imediata mediante a instalação de uma prótese fixa, com infra-estrutura metálica, 24 horas após a cirurgia. Estes pacientes foram acompanhados por um período de 12 meses. As medidas da estabilidade do implante foram realizadas no momento da instalação dos implantes (M0) e após seis (M6) e 12 meses (M12). Após o período de acompanhamento, foram obtidos índices de sucesso de 95% para os implantes e 90% para as próteses. Quanto aos valores da estabilidade dos implantes, foi observada uma diferença estatisticamente significativa entre os valores de M0 e M6, e, M0 e M12. Sendo o M0, o momento com maior valor do coeficiente de estabilidade. Não houve diferença estatisticamente significativa entre os valores da estabilidade obtidos no M6 e M12. Quando comparados, o valor da estabilidade para cada implante, não apresentaram diferença estatisticamente significativa no mesmo período de avaliação... / Brånemark et al. (1969) presented the osseointegrated implants as a way to anchorage prosthesis for missing teeth substitution in the jaws. Ever since, modifications in the classical protocol were instituted. Among them, the functional loading of the implants, immediately after their installation. This procedure have been well documented in mandibles, with high success levels, however, literature is scarce about the application of this technique in maxilla. The purpose of this study is to evaluate the immediate function in implants installed in totally edentulous maxillas, at the surgical moment and after six and 12 months of function. For so much, a modified surgical technique was used and implant stability was evaluated through the resonance frequency analysis. Ten patients were selected, who received six implants installed in the maxilla and submitted to immediate function. A metallic infra-structure fixed prosthesis was installed 24 hours after the surgery. The follow-up period was of 12 months. Implant stability measurements were taken at the surgical moment (M0) and after six (M6) and 12 months (M12). After the follow-up period, success rates of 95% for implants and 90% for prosthesis were achieved. As for the implant stability values, significant statistical difference were observed between M0 and M6, and M0 e M12, and no significant statistical difference was observed between M6 and M12. When the stability values of each implant was compared, no significant statistical difference was observed between them for different evaluation periods. It is concluded that the submission of implants, installed in the maxilla through a modified technique, to immediate function is a well predictable procedure, ever since well selected and executed. The resonance frequency analysis is an efficient method for the evaluation of the initial and late implants’ stability.
|
36 |
Implantes do sistema T. F. (Tissue functional) em alvéolos imediatamente após exodontia com e sem membrana de osso bovino: estudo histológico em cãesPalma, Vinícius Canavarros [UNESP] January 1998 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:41Z (GMT). No. of bitstreams: 0
Previous issue date: 1998Bitstream added on 2014-06-13T19:30:05Z : No. of bitstreams: 1
palma_vc_me_araca.pdf: 1901669 bytes, checksum: 33ec6f01ba3fb930bfa9ba761cd9b128 (MD5) / O protocolo convencional para que ocorra osseointegração sugere aguardar até 6 meses para o processo de reparo alveolar, antes da colocação de um implante. Os implantes imediatos são implantes colocados em alvéolos preparados imediatamente após a exodontia. Estes implantes apresentam vantagens, pois eliminam o período de reparação do alvéolo e um tempo cirúrgico, diminuindo o período para instalação da prótese. Reduz o custo e preserva altura e largura óssea alveolar, facilitando, desta maneira, a colocação do implante em relação ao seu comprimento, largura e angulação. Neste estudo a possibilidade de colocação de um implante de titânio em alvéolos imediatamente após a extração de pré-molares inferiores foi investigada. Dezesseis implantes (9x4mm) foram colocados em alvéolos preparados imediatamente após a exodontia em oito cães. Oito implantes foram recobertos com membrana reabsorvível e a outra metade não recebeu membrana. Um espaço esteve presente nas margens laterais de todos os implantes. Este espaço foi preenchido por coágulo e sutura oclusiva foi conseguida em todos os animais. Os animais foram sacrificados nos períodos de 40, 60, 90 e 120 dias após a implantação. Avaliações histológicas dos dois grupos mostraram que houve áreas de osseointegração. Conclui-se que o implante deve ficar o máximo em contato com o osso alveolar e que a membrana reabsorvível não promoveu a regeneração óssea guiada; ao contrário, o uso de membranas pode levar a diversas complicações. A partir dos resultados obtidos muitas questões surgem, gerando a possibilidade de vários outros estudos na tentativa de responder às limitações e dúvidas suscitadas pelo presente estudo. / The conventional osseointegration protocol calls for waiting up to 6 months for ossification of an extraction socket to heal before placing an endosseous implant. Immediate implants are implants placed into a prepared extraction socket following tooth removal. The advantages of the immediate implants include fewer surgical sessions, elimination of the waiting period for socket healing, shortened edentulous time period, reduced overall cost, as well as preservation of bone height and width. In this study the possibility of placing titanium implant directly into extraction socket immediately after extraction of mandibular premolars was investigated. Sixteen 9x4mm implants were placed into immediate extraction sockets in eight adult dogs. Eight implants were isolated with bioabsorbable membranes and eight sites served as controls. A space was present along the lateral border of all the implants. This gap was filled with clot and a primary flap closure was regarded. The animals were sacrificed 40, 60, 90 and 120 days after the implantations. Histologic evaluation of test and control specimens showed that the implants should be placed as close as possible to the alveolar crest level and the use of membranes did not imply better results; on the contrary, the use of membrane may lead to adverse complications. This study suggests that titanium implants have the potential to integrate when placed immediately after extraction of the teeth and warrants further investigation.
|
37 |
Avaliação clínica e da freqüência de ressonância, de implantes instalados por meio de técnica cirúrgica modificada na maxila e submetidos à função imediata /Vasconcelos, Laércio Wonhrath. January 2005 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Banca: Marco Antonio Bottino / Banca: Carlos Eduardo Francischone / Banca: Waldyr Antonio Janson / Banca: Per-Ingvar Branemark / Resumo: Brånemark et al. (1969) introduziram os implantes osseointegrados como forma de ancoragem para próteses com intuito de substituir os dentes perdidos, tanto na mandíbula como na maxila. Desde então, foram instituídas modificações no protocolo clássico. Entre elas, a submissão dos implantes à função imediatamente após a sua instalação. Esse procedimento tem sido largamente estudado na mandíbula, com altos índices de sucesso, contudo, a literatura é escassa quanto à aplicação desta técnica na maxila. Propôs-se, então, avaliar a função imediata em implantes instalados em maxilas desdentadas totais, no momento da cirurgia e após seis e 12 meses de função. Para tanto foi utilizada uma técnica cirúrgica modificada e a avaliação da estabilidade dos implantes foi feita por meio da análise da freqüência de ressonância. Foram selecionados 10 pacientes, nos quais foram instalados seis implantes na maxila com a submissão dos mesmos à função imediata mediante a instalação de uma prótese fixa, com infra-estrutura metálica, 24 horas após a cirurgia. Estes pacientes foram acompanhados por um período de 12 meses. As medidas da estabilidade do implante foram realizadas no momento da instalação dos implantes (M0) e após seis (M6) e 12 meses (M12). Após o período de acompanhamento, foram obtidos índices de sucesso de 95% para os implantes e 90% para as próteses. Quanto aos valores da estabilidade dos implantes, foi observada uma diferença estatisticamente significativa entre os valores de M0 e M6, e, M0 e M12. Sendo o M0, o momento com maior valor do coeficiente de estabilidade. Não houve diferença estatisticamente significativa entre os valores da estabilidade obtidos no M6 e M12. Quando comparados, o valor da estabilidade para cada implante, não apresentaram diferença estatisticamente significativa no mesmo período de avaliação...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Brånemark et al. (1969) presented the osseointegrated implants as a way to anchorage prosthesis for missing teeth substitution in the jaws. Ever since, modifications in the classical protocol were instituted. Among them, the functional loading of the implants, immediately after their installation. This procedure have been well documented in mandibles, with high success levels, however, literature is scarce about the application of this technique in maxilla. The purpose of this study is to evaluate the immediate function in implants installed in totally edentulous maxillas, at the surgical moment and after six and 12 months of function. For so much, a modified surgical technique was used and implant stability was evaluated through the resonance frequency analysis. Ten patients were selected, who received six implants installed in the maxilla and submitted to immediate function. A metallic infra-structure fixed prosthesis was installed 24 hours after the surgery. The follow-up period was of 12 months. Implant stability measurements were taken at the surgical moment (M0) and after six (M6) and 12 months (M12). After the follow-up period, success rates of 95% for implants and 90% for prosthesis were achieved. As for the implant stability values, significant statistical difference were observed between M0 and M6, and M0 e M12, and no significant statistical difference was observed between M6 and M12. When the stability values of each implant was compared, no significant statistical difference was observed between them for different evaluation periods. It is concluded that the submission of implants, installed in the maxilla through a modified technique, to immediate function is a well predictable procedure, ever since well selected and executed. The resonance frequency analysis is an efficient method for the evaluation of the initial and late implants' stability. / Doutor
|
38 |
Efeito do numero de ciclos de união e separação dos componentes sobre a retenção de sistemas de encaixes para overdentures / Retention force and fatigue strength of overdenture attachment systemPigozzo, Monica Nogueira 23 February 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T11:28:23Z (GMT). No. of bitstreams: 1
Pigozzo_MonicaNogueira_M.pdf: 2354060 bytes, checksum: cc00aca1a1073cf363d5005a5ed1a5d8 (MD5)
Previous issue date: 2007 / Resumo: Este trabalho teve como objetivo avaliar o efeito do número de ciclos de união e separação dos componentes sobre a retenção de 4 sistemas de encaixes para Overdenture do tipo barra-clipe. Foram confeccionados 40 corpos-de-prova, separados em 4 grupos de 10: 1- Conexão Sistema de Prótese (clipe de polímero); 2- Sterngold-Implamed (clipe de polímero); 3- 3i-Implant innovation (clipe metálico); e 4- SIN Sistema de Implante Nacional (clipe metálico). Os corpos-de-prova imersos em saliva artificial foram submetidos ao ensaio de ciclagem mecânica em máquina servohidraúlica MTS-810, realizando-se 5.500 ciclos (união e separação dos componentes) com freqüência de 0,8 Hz. Os valores da força de retenção foram monitorados em 6 registros por meio de ensaio de tração, utilizando o programa Test Work for Test Star com velocidade de 1mm/min, e célula de carga de 1 KN nos períodos: retenção inicial; em 1.100 ciclos de união e separação; 2.200 ciclos; 3.300 ciclos; 4.400 ciclos; e 5.500 ciclos. Os dados obtidos foram submetidos à análise de variância e aplicado o teste de Tukey (p<0,05). Os resultados mostraram que entre os grupos com clipes de polímeros não existiu diferença estatisticamente significante, enquanto os sistemas com clipes metálicos apresentaram diferença estatisticamente significante entre si, exceto após 5.500 ciclos. Os sistemas de retenção da Conexão e 3i apresentaram diferença estatisticamente significante após 4.400 ciclos. Os sistemas de retenção da Conexão e SIN apresentaram diferença estatisticamente significante em todosos ciclos, assim como os da Sterngold-Implamed e SIN. Os sistemas de retenção daSterngold-Implamed e 3i apresentaram diferença estatisticamente significante após 5.500ciclos. Os resultados permitiram concluir que: os sistemas avaliados apresentaram valores de força de retenção considerados satisfatórios em todos os tempos de registro, sendo os mais elevados apresentados pela Conexão e Sterngold-Implamed. Durante o experimento, não ocorreu diminuição nos valores da força de retenção, ou fratura dos componentes, em qualquer sistema avaliado / Abstract: The aim of the present study was to evaluate the effect of the number of insertion and removal cycles on retention force of four Overdenture bar-clip attachment systems. Sample included 40 specimens which were assigned to 4 groups (n=10): 1- Conexão Sistemas de Prótese (polymeric clip); 2- Sterngold-Implamed (polymeric clip); 3- 3i- Implant innovation (metallic clip); and 4- SIN Sistema de Implante Nacional (metallic/metal clip). Specimens immersed in artificial saliva were tested to 5.500 cycles at 0.8 Hz using a servohydraulic machine (MTS-810). During the test, retention force values were recorded 6 times using the tensile test (Test Works for Test Star) at a speed of 1mm/min, with a load cell of 1 KN: initial retention force; at 1100 insertion and removal cycles; 2200 cycles; 3300 cycles; 4400 cycles; and 5500 cycles). Data were submitted to analysis of variance (ANOVA) and Tukey test (p<0.05). No statistically significant difference was observed for the groups using polymeric clips; however, those using metallic clips showed significant difference, except after 5500 cycles. Conexão and 3i attachment systems showed statistically significant difference after 4400 cycles. Comparison between Conexão and SIN Systems and Sterngold-Implamed and SIN demonstrated significant difference at all cycles. Sterngold-Implamed and 3i systems showed statistically significant difference only after 5500 cycles. Results showed that the systems evaluated displayed satisfactory retention force values at all cycling periods tested, with the highest values observed for Conexão and Sterngold-Implamed. No component fractures or reduction in retention force values was found for any of the systems tested. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
39 |
Alterações dimensionais mandibulares e sua relação com atividade muscular em pacientes portadores de próteses implantossuportadas / Mandibular dimensional changes and its relationship with muscular activity in pacients when implant-supported prosthesis are usedTânia Mara de Tassis Mandelli 07 November 2008 (has links)
Objetivos: este estudo se propôs avaliar a correlação entre atividade do músculo masseter e alteração óssea mandibular, posterior ao último implante, um ano após a reabilitação com próteses implantossuportadas, em pacientes com fissura labiopalatina já reparada. Material e Método: As alterações dimensionais ósseas foram medidas em radiografias panorâmicas digitalizadas realizadas antes e um ano após a reabilitação de dezessete pacientes. A eletromiografia dos músculos masseteres foi realizada durante a contração voluntária isométrica máxima (CVIM) por 5s, mastigação habitual de cenoura (MH), mastigação unilateral direita (MUD) e esquerda (MUE) de látex. Resultados: ocorreu aumento ósseo significativo na mandíbula de 1,98mm (p<0,001) para o tipo de prótese inferior overdenture implantossuportada. O lado direito é maior que o esquerdo em 0,9mm. Um significante aumento da amplitude para a MH (9V) e para a MUE (19V) foi observado, independente do tipo de prótese. Um aumento significante para a MUE (19V) foi observado para a prótese overdenture. Ocorreu um aumento estatisticamente significante para o ato mastigatório durante os três tipos de mastigação (MH=0,13s, MUD=0,06s, MUE=0,12s), independente do tipo de prótese. Para o ciclo mastigatório também foi observado aumento estatisticamente significante, independente do tipo de prótese durante a MH (0,12s) e MUE (0,11s). Conclusão: Ocorreu aposição óssea na região posterior da mandíbula para a prótese overdenture e apesar do aumento da atividade muscular, não foi encontrada correlação estatisticamente significante com a atividade muscular do masseter. / Purpose: The purpose of the present study was to evaluate the correlation between masseter muscle activity and changes occurred in mandibular bone height, posterior to the last implant, one year after implant-supported prosthesis rehabilitation in repared cleft lip and palate patients. Materials and Methods: changes in mandibular bone height were measured in digitalized images of panoramic radiographies taken before and one year after oral rehabilitation of seventeen repared cleft lip and palate patients (Radiocef 2 Radiomemory). Parameters for electromyography of masseter muscle were: maximum voluntary isometric clench (MVC) for 5s, habitual chewing of carrots (HC) and unilateral right (URL) and left (ULL) chewing of latex. Results: a mean increase in mandibular bone height of 1,98mm (p<0,001) for the implant retained overdenture was observed. Bone apposition was higher in the right side. Significant increase in the amplitude was observed during HC (9V) and during ULL (19 V), regardless prosthesis type and side. A significant increase was observed during URL (19 V) for the implant retained overdenture. A significant statistical increase for the masticatory act was observed during the three types of mastication (HC=0,13s, URL=0,06s, ULL=0,12s), regardless prosthesis types. A significant statistical increase was observed for the masticatory cycle during HC (0,12s) and ULL (0,11s), regardless prosthesis type. Conclusion: Mandibular bone apposition in the posterior region to the last implant, in patients using implant retained overdentures and improvement in muscular activity in both types of prosthesis were observed, although no significant correlations were encountered between them.
|
40 |
A comparative study to evaluate patient satisfaction with conventional dentures and implant retained overdenturesAl-Makki, Amjad January 2006 (has links)
Magister Scientiae Dentium - MSc(Dent) / The edentulous jaw is a common feature in elderly patients that had lost their teeth during life due to local reasons such as poor oral hygiene and dental caries as well as periodontal disease. Hence these patients are the victims of biological phenomenona that lead to difficulties in different aspects of patient comfort with dentures. Clinicians are always concerned to minimize these difficulties and increase patient comfort through manufacturing a proper prosthesis to substitute for the loss of the natural teeth as well as the surrounding structures for optimum satisfaction and improved quality of life of the patient. The aim of this study was to evaluate patient satisfaction regarding function and aesthetics with conventional mandibular dentures and implant retained mandibular overdentures in denture wearers. / South Africa
|
Page generated in 0.0945 seconds