• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 746
  • 339
  • 171
  • 67
  • 47
  • 44
  • 32
  • 15
  • 12
  • 12
  • 10
  • 10
  • 7
  • 6
  • 5
  • Tagged with
  • 1756
  • 1756
  • 343
  • 310
  • 304
  • 203
  • 184
  • 172
  • 154
  • 150
  • 143
  • 139
  • 131
  • 125
  • 125
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Resistência, densidade e desempenho termo-acústico do concreto com espuma de poliestireno expandido (EPS) aplicado às construções / Resistance, density and thermal-acoustic performance of concrete with foam from expanded polystyrene (eps) applied to buildings

Wolff, Paulo Sérgio 24 July 2008 (has links)
Made available in DSpace on 2017-05-12T14:47:50Z (GMT). No. of bitstreams: 1 PAULO SERGIO WOLFF.pdf: 1931589 bytes, checksum: f57f8dc01ee1f4a88bdb2471b6e4fba0 (MD5) Previous issue date: 2008-07-24 / The use of expanded polystyrene (EPS) packing has contributed for the production of solid residues in the agricultural and urban environments. This leads to a considerable amount of ambient impact, since same is discarded in garbage deposits, leading approximately one hundred years to degrade. One alternative to solve this problem is the use of this residue as aggregate in concrete, having as final product the light concrete, reducing the consumption of natural resources and ambient damages. The light concrete can be applied in the agricultural constructions, mainly in installations for animals, cold chambers, and climatization of silos, warehouses and deposits for grains. In this work it was verified the viability of use of an alternative material for concrete production, with partial substitution of the coarse aggregate, which can be used in urban and agricultural constructive elements. Reused EPS in the form of flakes was employed for production of light concrete. The experiments had been systematically carried through with cylindrical specimens and concrete plates after 28 days of curing. The rate of substitution of the coarse aggregate by EPS had been of 0% (reference), 25%, 50%, 75% and 100% in volume, as base to carry through the analyzes of density and strength corresponding to 7, 14, 21 and 28 days of curing, in accordance to ABNT's standards. It was verified that the assayed plates had presented a heat transfer reduction of up to 30% and reduction of sound propagation of up to 25%. With regard to the density, it was verified a reduction of up to 30%, generating a light concrete, making the structure lighter and bringing economy in the sizing of the structure. On the other hand, a reduction of the resistance from a certain content of EPS occurred, restricting the use of such concrete to closing, nonstructural, elements. The substitution of the coarse aggregate by EPS gradually produces a lighter concrete due to the addition of voids, what it made possible to obtain a thermal and acoustic isolating material. A direct consequence of the use of the light concrete is the reduction of the consumption of electric energy used by the climatization systems, not compromising the thermal and acoustic comfort in the urban and agricultural constructions. Besides the reuse of the industrial discarding and EPS packing as alternative materials of construction, it must be detached the reduction of the ambient problems caused by the materials used in the concrete production. / O uso de embalagens de poliestireno expandido (EPS) tem contribuído para a produção de resíduos sólidos no meio rural e urbano, gerando impactos ambientais consideráveis, por seu descartado na natureza ou em lixões, pois esse material demora, aproximadamente, cem anos para se degradar. Uma das soluções é o uso desse resíduo como agregado no concreto, tendo como resultado o concreto leve, reduzindo o consumo de recursos naturais e danos ambientais. O concreto leve pode ser aplicado em construções rurais, principalmente em instalações para animais, câmaras frias, climatização de silos, armazéns e depósitos para grãos. Neste trabalho, verificou-se a viabilidade da utilização de EPS como material alternativo para confecção de concreto, com substituição parcial do agregado graúdo, que pode ser utilizado em elementos construtivos urbanos e rurais. Utilizou-se EPS reaproveitada na forma de flocos, para produção de concreto leve. Os experimentos foram realizados sistematicamente com amostras na forma de corpos de prova cilíndricos e placas de concreto com 28 dias de idade. Os teores de substituição da brita por EPS foram de 0% (referência), 25%, 50%, 75% e 100% em volume, como base para realizar as análises de densidade e resistência aos 7, 14, 21 e 28 dias, de acordo com as normas da ABNT. Verificou-se que as placas ensaiadas apresentaram uma redução de transferência de calor de até 30% e redução de propagação de som de até 25% e, em relação à densidade, verificou-se uma redução de até 30%, possibilitando o uso de um concreto leve nas construções, tornando a sua estrutura leve e trazendo economia no seu dimensionamento. Por outro lado, ocorreu uma diminuição da resistência a partir de certo teor de EPS, fazendo com que o uso tenha maior aplicação como elemento de vedação sem fins estruturais. A substituição da brita pelo EPS, gradativamente, produz um concreto leve devido ao acréscimo do número de vazios, o que possibilita um material isolante térmico e acústico. Uma conseqüência direta do uso do concreto leve é a redução do consumo de energia elétrica utilizada pelos sistemas de climatização, não comprometendo o conforto térmico e acústico das edificações. Destaca-se, ainda, que o reaproveitamento do descarte industrial e de embalagens do EPS, como material alternativo de construção contribui para a redução dos problemas ambientais causados pelos materiais utilizados na fabricação do concreto.
362

Fachada de edifício residencial em vidro no século XXI : clima, conforto e conservação de energia

Caselli, Cristina Kanya 02 December 2011 (has links)
Made available in DSpace on 2016-03-15T19:23:59Z (GMT). No. of bitstreams: 1 Cristina Kanya Caseli.pdf: 10411066 bytes, checksum: 5bdc7226c2eff8b8801b64464bcf577f (MD5) Previous issue date: 2011-12-02 / Fundo Mackenzie de Pesquisa / Architects have a fascination for the glass, as curtain walls are present on every city in the world, regardless of the local weather and the usage of buildings. Glass allows the integration between the interior and the exterior and vice-versa, playing an important role in making an architecture project coming to life, useful. The solution for the equation that involves: envelope; residential buildings, glass, weather, comfort and energy conservation on 21st century is taking advantage of the transparency qualities and resistance of the glass in order to create envelopes fully adapted to the local climatic reality without harming the environmental comfort of the residential buildings users, focused on the market from São Paulo / Os arquitetos têm fascínio pelo vidro, tanto que as peles de vidro estão por todas as cidades do mundo, independente do clima local e uso da edificação. O vidro permite a integração do interior com exterior e vice versa, sendo um importante instrumento para o projeto arquitetônico se tornar vivo, útil. A solução da equação que abrange os fatores: fachada; edifício residencial; vidro; clima; conforto e conservação de energia no século XXI está em tirar vantagem das qualidades de transparência e resistência do vidro para criar fachadas adaptadas a realidade climática local sem o prejuízo do conforto ambiental do usuário de construções residenciais, voltadas ao mercado paulistano
363

Telhado verde e sua contribuição para a redução da temperatura ambiente em construções para Cascavel/PR / Green roof and its contribution to reducing the room temperature in buildings to Cascavel/PR

Souza, Cássia Rafaela Brum 15 February 2016 (has links)
Made available in DSpace on 2017-07-10T15:14:38Z (GMT). No. of bitstreams: 1 Cassia.pdf: 2786981 bytes, checksum: 5b6d10db8b160b6e3fcd9969190b981f (MD5) Previous issue date: 2016-02-15 / Since the second half of the nineteenth century, energy plays a key role in the gear of modern industrial society, moving numerous systems and equipment, but its overuse has caused its scarcity. Assuming that renewable energy comes from renewable resources, naturally replenished, from the sun, wind, rain, tides and geothermal energy, some can be exploited intensively, and when combined with bioclimatic architecture and energy efficiency can have adequate thermal inertia a building with adequate insulation elements, maintaining thermal comfort inside the room during times of peak temperature and solar radiation outside and thus respectively controlling excess heat. To this end this work becomes significant because it was developed in order to provide two different conditions of buildings, in which the cover is differentiating factor for withdrawals and verification of energy efficiency. The research shows the variation of the internal temperature of the environment covered by the green roof and a conventional, and their loss to the environment over the hours of the day and night as well as the influence of the green roof substrate at room temperature inside, demonstrating the efficiency of the green roof. / Desde a segunda metade do século XIX, a energia desempenha papel fundamental na engrenagem da sociedade industrial moderna, movimentando inúmeros sistemas e equipamentos, porém seu uso demasiado vem causando a sua escassez. Partindo do pressuposto de que a energia renovável vem de recursos renováveis, naturalmente reabastecidos, proveniente do sol, vento, chuva, marés e energia geotérmica, algumas podem ser exploradas intensivamente, e quando aliadas a arquitetura bioclimática e eficiência energética pode-se ter ganhos consideráveis com a inércia térmica em uma edificação, com elementos de adequado isolamento, assegurando o conforto térmico no interior do ambiente durante horas de maior temperatura e radiação solar no exterior e assim respectivamente, controlar o excesso de calor. Com este objetivo o trabalho se torna expressivo, pois foi desenvolvido a fim de propiciar duas condições diferentes de construções, nas quais a cobertura é fator diferencial para os levantamentos e verificação da eficiência energética, obtendo resultados relevantes quando comparados os dois protótipos do experimento, um com telhado convencional e outro com telhado verde. A pesquisa apresentou a variação das temperaturas internas do ambiente coberto pelo telhado verde e de um convencional, e suas perdas para o meio ao longo das horas do dia e da noite, bem como a influência do substrato do telhado verde na temperatura interna do ambiente, demonstrando a eficiência do telhado verde.
364

Eficiência energética e intensidade de emissões no setor de papel e celulose brasileiro / Energy efficiency and emissions intensity in the Brazilian pulp and paper sector

Fracaro, Guilherme de Paula Moreira 16 February 2012 (has links)
Made available in DSpace on 2017-07-10T15:14:44Z (GMT). No. of bitstreams: 1 Guilherme de Paula Moreira Fracaro.pdf: 1427700 bytes, checksum: f759217009e2ccbcf53a1f94eb64e5bf (MD5) Previous issue date: 2012-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Industrial energy efficiency has received increasing attention in many countries because of its importance in the pursuit of security of energy supply, increased competitiveness in the economy and in the mitigation of greenhouse gases emissions. This dissertation aimed to evaluate the energy consumption development of Brazilian pulp and paper industry, a sector classified and energy-intensive and with significative importance both in terms of energy and economic. Both the emissions intensity of greenhouse gases, arising from the sector energy consumption, and the developments of the energy efficiency levels were analysed, estimating the existing energy saving potentials. Through a decomposition analysis, the influences of changes in the struture, production intensity and energy efficiency levels in the increased sector energy consumption over time were evaluated. In order to contextualize the changes occurred in the country, an international comparison of the development of both the energy efficiency levels and the energy consumption decomposition of other importante producing countries: Canada, United States of America, Finland and Sweden were held. It was concluded in this study that the emissions intensity of carbon dioxide equivalent by the national industry decreased significantly between 1979 and 2010, from 1.24 to 0.31 CO2e per tonne of exported pulp and produced paper. Despite a significant increase in the energy efficiency levels, responsible for 5.5 PJ savings in electricity consumption and for 37.6 PJ savings in fuels consumptions between 1979 and 2009, it was identified a saving potential of 7.3 PJ and 105.5 PJ related to the annual consumption of electricity and fuels, respectively, in the Brazilian pulp and paper industry. Among the countries evolved in the international comparison, both Swedish and Finnish industreis were the most eficiente, followed by the Brazilian, American and Canadian, being the latter the only one where there was a reduction in the energy efficiency levels over the analysed period. Keywords: energy-efficiency; decomposition analysis; international comparison. / A eficiência energética industrial vem recebendo crescente atenção em diversos países por sua importância na busca por segurança de suprimento energético, aumento de competitividade na economia e mitigação das emissões de gases de efeito estufa. Esta dissertação teve por objetivo avaliar o desenvolvimento do consumo energético da indústria de papel e celulose no Brasil, setor classificado como energo-intensivo e com significativa importância tanto em termos energéticos quanto econômicos no país. Analisou-se o desenvolvimento da intensidade de emissões de gases de efeito estufa, decorrentes do consumo energético do setor, e os desenvolvimentos dos níveis de eficiência energética, estimando-se os potenciais de conservação de energia existentes. Através de uma análise de decomposição, avaliou-se as influências das mudanças estruturais, de intensidade de produção e dos níveis de eficiência energética no aumento do consumo de energia pelo setor ao longo do tempo. Afim de contextualizar as alterações ocorridas no país, realizou-se uma comparação internacional dos desenvolvimentos dos níveis de eficiência e da decomposição do consumo energético em outros importantes países produtores: Canadá, Finlândia, Suécia e Estados Unidos da America. Concluiu-se neste estudo foram que a intensidade das emissões de dióxido de carbono equivalente pela indústria nacional reduziu significativamente entre 1979 e 2010, de 1,24 para 0,31 tCO2e por tonelada de celulose exportada e papel produzido. Apesar de um importante aumento dos níveis de eficiência energética, responsável por uma economia de 5,5 PJ em eletricidade e 37,6 PJ em combustíveis entre 1979 e 2009, identificou-se ainda um potencial de aproximadamente 7,3 PJ e 105,5 PJ para a conservação anual de eletricidade e combustíveis, respectivamente, na indústria brasileira de celulose e papel. Entre os países envolvidos na comparação internacional, as indústrias sueca e finlandesa mostraram-se como as mais eficientes, seguidas pelas indústrias brasileira, estadunidense e canadense, sendo esta última a única onde ocorreu uma redução nos níveis de eficiência energética para o período analisado.
365

Análise energética e econômica em uma agroindústria de laticínios / Economic and energy analysis on dairy agroindustry

Lawder, José Henrique 03 February 2012 (has links)
Made available in DSpace on 2017-07-10T15:14:45Z (GMT). No. of bitstreams: 1 Jose Henrique Lawder.pdf: 1684315 bytes, checksum: baa427ab3ae9e5eba4e83d240cb1e26f (MD5) Previous issue date: 2012-02-03 / This research constituted a case study related to an energy audit that was done in the Laticínios Guaíra Ltda company, a dairy producer industrial entity, located at Guaira city, western Paraná. Located in a region of high average temperatures in the summer season, the company needs to generate large-scale cold for dairy food production and preservation produced. This motivated us to do a close study about the transformation of energy within the company, plus a full diagnosis of end uses of the company such as driving force, cooling and lighting. The strategy of this work was to monitor the company's production process, indicating points of possible improvements in the work methodology of the unit. At the end of the study an analysis of technical and economic viability showed to the owners of the organization which actions could be able to take effect and the financial gain realized with these measures. The main results obtained with the recommendations of this audit were the reduction of 11.490,50 kWh per month in electricity consumption of the company, representing a monthly savings of R$ 2.191,35 in electricity bills. The conclusion of the study confirmed the economic viability of energy efficiency measures presented by replacing lamps and motors with more efficient ones. The discounted payback values of thirty months, the internal rate of return of 3.93% a month and cost-benefit ratio of 0.30 justify the economic feasibility of the proposed conservation measures. / Este trabalho de pesquisa se constituiu num estudo de caso referente a uma Auditoria Energética que se efetuou na empresa Laticínios Guaíra Ltda, entidade industrial produtora de alimentos lácteos, localizada na cidade de Guaíra, Extremo- Oeste paranaense. Localizada numa região de altas temperaturas médias na estação de verão, a empresa necessita gerar frio em grande escala para produção e conservação dos alimentos lácteos produzidos. Isto motivou a fazer um estudo minucioso sobre a transformação de energia dentro da empresa, além de um completo diagnóstico dos usos finais da empresa, tais como: força motriz, refrigeração e iluminação. A estratégia deste trabalho consistiu em acompanhar o processo produtivo da empresa, indicando pontos de possíveis melhorias na metodologia de trabalho da unidade. Ao final do estudo, uma análise de viabilidade técnica e econômica mostrou aos proprietários da empresa as ações que poderiam ser efetivadas e o ganho financeiro auferido com estas medidas. Um dos principais resultados obtidos com as recomendações desta auditoria foi a redução de 11.490,50 kWh por mês no consumo de energia elétrica da empresa, representando uma economia mensal de R$ 2.191,35 na fatura de eletricidade. A conclusão do estudo confirmou a viabilidade econômica das medidas de eficiência energética apresentadas, através da substituição das lâmpadas e motores por outros mais eficientes. Os valores do payback descontado de trinta meses, a taxa interna de retorno de 3,93% ao mês e a relação custo-benefício de 0,30 justificam a viabilidade econômica das medidas de conservação propostas.
366

Energy efficiency investments in residential buildings : does personality matter?

Busic-Sontic, Ante January 2019 (has links)
In recent years, energy efficiency in the built environment has been attracting considerable interest to mitigate energy consumption. A number of scientific studies indicate that rising air pollution, decreasing biodiversity, ocean acidification and other adverse effects on humans and the environment in recent decades are due to greenhouse gas emissions, and a substantial share of the emissions can be attributed to energy usage in residential buildings. Investments in energy-efficient technologies have been made to alleviate such human induced causes contributing to the emissions, but they are still far from widespread, calling for a thorough understanding of individuals' decision-making processes to promote further adoption of energy efficiency investments. Although personality has been widely recognised as an explanatory factor of behaviour, a rigorous discussion of it in the context of energy efficiency investments is missing. As such, to understand the role of personality traits in making high-cost energy efficiency investments in residential buildings, this research applies a multidisciplinary approach to derive theoretical models that are evaluated in subsequent empirical investigations using quantitative methods and data from the UK and Germany. The findings suggest three ways through which personality can influence energy efficiency investments. The first is an indirect impact of personality traits through risk preferences, in which the significance of the personality effects depends on the financial subsidy context. The second is an indirect effect of personality traits through environmental concern. The third way suggests an impact of personality traits through their importance for individuals' capability and willingness to consider peer behaviour.
367

Dynamic CPU frequency scaling using machine learning for NFV applications. / Escalamento dinâmico de frequência da CPU usando aprendizado de máquina em aplicações NFV.

Ligia Maria Moreira Zorello 10 October 2018 (has links)
Growth in the Information and Communication Technology sector is increasing the need to improve the quality of service and energy efficiency, as this industry has already surpassed 12% of global energy consumption in 2017. Data centers correspond to a large part of this consumption, accounting for about 15% of energy expenditure on the Information and Communication Technology domain; moreover, the subsystem that generates the most costs for data center operators is that of servers and storage. Many solutions have been proposed to reduce server consumption, such as the use of dynamic voltage and frequency scaling, a technology that enables the adaptation of energy consumption to the workload by modifying the operating voltage and frequency, although they are not optimized for network traffic. In this thesis, a control method was developed using a prediction engine based on the analysis of the ongoing traffic. Machine learning algorithms based on Neural Networks and Support Vector Machines have been used, and it was verified that it is possible to reduce power consumption by up to 12% on servers with Intel Sandy Bridge processor and up to 21 % in servers with Intel Haswell processor when compared to the maximum frequency, which is currently the most used solution in the industry. / O crescimento do setor de Tecnologia da Informação e Comunicação está aumentando a necessidade de melhorar a qualidade de serviço e a eficiência energética, pois o setor já ultrapassou a marca de 12% do consumo energético global em 2017. Data centers correspondem a grande parte desse consumo, representando cerca de 15% dos gastos com energia do setor Tecnologia Informação e Comunicação; além disso, o subsistema que gera mais custos para operadores de data centers é o de servidores e armazenamento. Muitas soluções foram propostas a fim de reduzir o consumo de energia com servidores, como o uso de escalonamento dinâmico de tensão e frequência, uma tecnologia que permite adaptar o consumo de energia à carga de trabalho, embora atualmente não sejam otimizadas para o processamento do tráfego de rede. Nessa dissertação, foi desenvolvido um método de controle usando um mecanismo de previsão baseado na análise do tráfego que chega aos servidores. Os algoritmos de aprendizado de máquina baseados em Redes Neurais e em Máquinas de Vetores de Suporte foram utilizados, e foi verificado que é possível reduzir o consumo de energia em até 12% em servidores com processador Intel Sandy Bridge e em até 21% em servidores com processador Intel Haswell quando comparado com a frequência máxima, que é atualmente a solução mais utilizada na indústria.
368

Contribuição da inércia térmica na eficiência energética de edifícios de escritórios na cidade de São Paulo. / Effect of the thermal inertia on the energy performance of office buildings in the city of São Paulo.

Brito, Adriana Camargo de 02 October 2015 (has links)
Diante das crises energéticas mundiais é oportuna a retomada de técnicas passivas de climatização de ambientes, como aquelas que consideram a inércia térmica das edificações. No Brasil é reconhecida a sua importância na melhoria do desempenho térmico de habitações, como indicado na norma NBR 15575 que, no método simplificado de avaliação do desempenho térmico, estabelece valores limites para a transmitância térmica e para a capacidade térmica de paredes, de modo a contemplar a influência da inércia térmica. Entretanto, não se dispõe de informações que permitam extrapolar esses critérios para edifícios de escritórios, que têm diferentes dinâmicas de uso e volumetria. Tendo como principal objetivo apresentar recomendações e critérios para o projeto de edifícios de escritórios na cidade de São Paulo, onde a inércia térmica dos ambientes pode contribuir para a redução ou a eliminação do uso de sistemas de ar condicionado, foi desenvolvido o presente trabalho. Para tal foram efetuadas simulações computacionais da resposta térmica de escritórios, analisados com variações nos seguintes parâmetros: área de piso; proporção de área na fachada em relação ao seu volume; nível de ocupação; taxa de ventilação; cor da fachada; sombreamento de aberturas; tipo de parede e temperatura de referência para o conforto térmico dos usuários. De modo geral, os resultados demonstraram que: ambientes ocupados, com paredes de maior capacidade térmica, menor área de piso e maior área na fachada em relação ao volume do ambiente, têm melhor desempenho térmico, especialmente com o uso de cores claras nas fachadas e dispositivos de sombreamento em aberturas. Tais características têm contribuição mais significativa na redução da demanda por climatização de ambientes somente se for adotada uma temperatura de referência do ar interior acima dos valores tipicamente usados nessas edificações. As recomendações e critérios apresentados para o projeto de escritórios consideram o uso de ambientes com ventilação, utilizando-se sistemas de climatização somente em menos de 15% das horas de um ano típico da cidade de São Paulo. / The global energy crises provide a further reason to use passive techniques, such as the thermal inertia, for cooling buildings. In Brazil, the importance of thermal inertia for the improvement of the thermal performance of dwellings is recognized and has been incorporated into the standard NBR 15575. For the assessment of the thermal performance, this standard establishes limit values for the thermal transmittance and the thermal capacity of walls, taking into account the influence of thermal inertia. However, there is no equivalent information available for offices, which can have very different characteristics. This thesis develops recommendations and criteria for the design of office buildings in the city of São Paulo, where the thermal inertia contributes to a reduction of energy consumption for cooling. Parametric simulations of typical offices were performed, varying the following parameters: floor area; façade-surface-area/volume ratio; internal gains (people, equipment etc.); ventilation rate; facade color and shading. The results showed that offices with walls made of components with higher thermal capacity, smaller floor area and larger façade-surface-area/volume ratio have better thermal performance. Light colors of the façade, shading devices and increased ventilation rate provided further improvement in the thermal performance of the offices. These characteristics may have significant contribution in reducing the energy demand for cooling depending on the value of the inside air temperature adopted. The recommendations and criteria presented for design of offices consider the use of air conditioning in less than 15% of the hours in a typical year in the city of São Paulo.
369

Eficiência energética e capacidade: estratégias de alocação de recursos em redes sem fio de múltiplo acesso. / Energy efficiency and capacity: resource allocation strategies in wireless multiple acess networks.

Sampaio, Lucas Dias Hiera 13 May 2015 (has links)
Neste trabalho são investigados problemas de alocação de espetro e potência em redes sem fio de múltiplo acesso e propostas sete soluções distintas para diferentes cenários e topologias que serão enumeradas a seguir. Primeiramente o problema de maximização da eficiência energética em redes cooperativas do tipo multiportadora com múltiplo acesso por divisão de código de sequência direta é abordado e as seguintes soluções são apresentadas: duas abordagens na perspectiva de teoria de jogos, uma utilizando algoritmo de water-filling (1) e outra utilizando o algoritmo distribuído de controle de potência baseado no equilíbrio de Verhulst (2), uma terceira solução também inspirado no último algoritmo citado e na média dos coeficientes de canal das subportadoras do sistema (3); uma abordagem heurística utilizando o algoritmo dos vaga-lumes (4) e outra utilizando a otimização por enxame de partículas (5). Em segundo lugar, foram investigados problemas de otimização em sistemas de múltiplo acesso por divisão ortogonal de frequência com provisão de qualidade de serviço estatística. Nesta segunda topologia dois problemas distintos foram analisados: o primeiro problema de maximização da capacidade efetiva do sistema foi solucionado utilizando o método de decomposição dual de Lagrange (6), o segundo problema cujo objetivo é a maximização da eficiência energética efetiva foi investigado e um solução baseada na combinação do método de Dinkelba e da decomposição dual de Lagrange foi proposta (7). Simulações computacionais foram conduzidas tendo em vista averiguar o desempenho das abordagens propostas e, quando possível, tais resultados numéricos foram comparados àqueles obtidos a partir de algoritmos alternativos existentes na literatura. / This work investigates the spectrum and power allocation problems in wireless multiple access networks and seven dfferent solutions to different scenarios and topologies, which are enumerated as follows. Three distinct solutions are presented to the energy effiency maximization problem in multicarrier direct sequence code division multiple acess cooperative: two game theoretic approaches, one using the iterative water-filling algorithm (1) and another one using the distributed power control algorithm based on Verhulst equilibrium concept (2), and a third solution also based on the last algorithm but considering the average channel power gain (3); an heuristic approach using the firefly algorithm (4) and the particle swarm optimization algorithm (5). In orthogonal frequency division multiple acess networks, optimization problems considering a statistical quality of service metric were analyzed: the first one is the effective capacity maximization which was solved through Lagrange dual decomposition method (6). The second one, in which the objective is to maximize the effective energy effiency was addressed and solution based on the Dinkelba method and further application of Lagrange dual decomposition was developed (7). Simulations were conducted to verify the proposed approaches performance and, whenever possible, the numerical results were compared to previous solution proposed in the literature.
370

Avaliação dos indicadores de iluminação artificial estudo de caso: edificios comerciais e escola / Evaluation of artificial lighting indicators case studies: offices and school

Furuyama, Cristiane Mitiko Sato 29 October 2013 (has links)
O objetivo desse trabalho é verificar se os critérios e indicadores das certificações LEED New Construction, LEED Existing Building - Operations and Maintenance, LEED Comercial Interiors, AQUA Escritórios e Edifícios escolares e o regulamento brasileiro PROCEL, podem ser atendidos pelas tecnologias disponíveis no Brasil em termos de lâmpadas, luminárias, reatores (sistemas de iluminação), bem como avaliar se tais critérios e indicadores estão de acordo com as normas da ABNT e/ou normas internacionais. Para verificar os indicadores, foram realizadas simulações através do programa de cálculo Dialux 4.10/2012, utilizando os arquivos fotométricos fornecidos pelos fabricantes mais especificados no Brasil. Foram escolhidos dois estudos de caso para essa verificação, um escritório e uma escola que são ambientes comuns nas certificações e selos de sustentabilidade que serão analisados. Os resultados das simulações mostrarão se é possível obter as certificações e/ou selo de sustentabilidade utilizando a tecnologia disponível referente aos sistemas de iluminação comercializados nos dias de hoje. / The main goal of this dissertation is to verify if Brazilian available technology can meet some certification´s criteria and indicators. The chosen certifications are: LEED New Construction, LEED Existing Building - Operations and Maintenance, LEED Comercial Interiors, AQUA offices and educational buildings and the Brazilian standard PROCEL. Lamps, fixtures, ballasts (lighting systems), were analyzed to check whether these criteria and indicators are in line with the ABNT and / or international standards. To check the indicators, simulations were performed using DIALUX 4.10/2012, a professional light planning software. In these simulations the most specified photometric files provided by the manufacturers were used. To this research two cases were chosen for analysis, an regular office and a school, that are common environments in sustainability standards and certifications. Simulation results will show if it is possible to obtain a certification using the available technology in lighting systems.

Page generated in 0.0803 seconds