• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 194
  • 29
  • 20
  • 18
  • 7
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 336
  • 336
  • 80
  • 67
  • 60
  • 59
  • 55
  • 55
  • 54
  • 54
  • 54
  • 54
  • 54
  • 54
  • 49
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Multihop clustering algorithm for load balancing in wireless sensor networks

Israr, Nauman, Awan, Irfan U. January 2007 (has links)
Yes / The paper presents a new cluster based routing algorithm that exploits the redundancy properties of the sensor networks in order to address the traditional problem of load balancing and energy efficiency in the WSNs.The algorithm makes use of the nodes in a sensor network of which area coverage is covered by the neighbours of the nodes and mark them as temporary cluster heads. The algorithm then forms two layers of multi hop communication. The bottom layer which involves intra cluster communication and the top layer which involves inter cluster communication involving the temporary cluster heads. Performance studies indicate that the proposed algorithm solves effectively the problem of load balancing and is also more efficient in terms of energy consumption from Leach and the enhanced version of Leach.
112

An efficient cluster-based communication protocol for wireless sensor networks

Bajaber, Fuad G., Awan, Irfan U. January 2014 (has links)
No / A wireless sensor network is a network of large numbers of sensor nodes, where each sensor node is a tiny device that is equipped with a processing, sensing subsystem and a communication subsystem. The critical issue in wireless sensor networks is how to gather sensed data in an energy-efficient way, so that the network lifetime can be extended. The design of protocols for such wireless sensor networks has to be energy-aware in order to extend the lifetime of the network because it is difficult to recharge sensor node batteries. We propose a protocol to form clusters, select cluster heads, select cluster senders and determine appropriate routings in order to reduce overall energy consumption and enhance the network lifetime. Our clustering protocol is called an Efficient Cluster-Based Communication Protocol (ECOMP) for Wireless Sensor Networks. In ECOMP, each sensor node consumes a small amount of transmitting energy in order to reach the neighbour sensor node in the bidirectional ring, and the cluster heads do not need to receive any sensed data from member nodes. The simulation results show that ECOMP significantly minimises energy consumption of sensor nodes and extends the network lifetime, compared with existing clustering protocol.
113

Guidelines for Greening (Renovation) of Existing Homes

Shaikh, Gilman Yusuf 12 1900 (has links)
This Thesis is aimed at evaluating the options of renovation for an existing residential building to make it more energy efficient. The various aspects in the basic structures of residential homes are discussed in order to help the user identify the areas of the house for which renovation is required to improve the energy efficiency of the building. These aspects include doors, roof and wall in addition to various systems of electrical wiring, mechanical systems of ventilation, heating and cooling and plumbing systems for the efficient flow of water throughout the house. The renovation options have been described in detail to provide as many possibilities to the user as possible. The building taken for renovation is a 1953 suburban home which has been awarded the honor of being the first building to be labeled as Zero Energy Home in its vicinity. This has made the home so efficient that its expenditure of energy has become equivalent to its energy generation, therefore, cancelling each other out and creating an estimate of zero energy.
114

Demand-side management in office buildings in Kuwait through an ice-storage assisted HVAC system with model predictive control

Al-Hadban, Yehya January 2005 (has links)
Examining methods for controlling the electricity demand in Kuwait was the main objective and motivation of this researchp roject. The extensiveu se of air-conditioning for indoor cooling in office and large commercial buildings in Kuwait and the Gulf States represents a major part of the power and electricity consumption in such countries. The rising electricity generation cost and growing rates of consumption continuously demand the construction new power plants. Devising and enforcing Demand-SideM anagemen(t DSM) in the form of energye fficient operations trategies was the response of this research project to provide a means to rectify this situation using the demand-side management technique known as demand levelling or load shifting. State of the art demand-sidem anagementte chniquesh ave been examined through the developmenot f a model basedp redictive control optimisations trategyf or an integrateda ndm odulara pproachto the provisiono f ice thermals torage. To evaluate the potential of ice-storage assisted air-conditioning systems in flattening the demand curve at peak times during the summer months in Kuwait, a model of a Heating, Ventilation, and Air-conditioning (HVAC) plant was developed in Matlab. The model engaged the use of model based predictive control (MPQ as an optimisation tool for the plant as a whole. The model with MPC was developed to chose and decide on which control strategy to operate the integrated ice-storage HVAC plant. The model succeeded in optimising the operation of the plant and introduced encouraging improvement of the performance of the system as a whole. The concept of the modular ice-storage system was introduced through a control zoning strategy based on zonal orientation. It is believed that such strategy could lead to the modularisation of ice-storage systems. Additionally, the model was examined and tested in relation to load flattening and demonstrated promising enhancement in the shape of the load curve and demonstrated flattened demand curves through the employed strategy. When compared with measured data from existing buildings, the model showed potential for the techniques utilised to improve the load factor for office buildings.
115

Capacity of Communications Channels with 1-Bit Quantization and Oversampling at the Receiver

Krone, Stefan, Fettweis, Gerhard 25 January 2013 (has links) (PDF)
Communications receivers that rely on 1-bit analogto-digital conversion are advantageous in terms of hardware complexity and power dissipation. Performance limitations due to the 1-bit quantization can be tackled with oversampling. This paper considers the oversampling gain from an information-theoretic perspective by analyzing the channel capacity with 1-bit quantization and oversampling at the receiver for the particular case of AWGN channels. This includes a numerical computation of the capacity and optimal transmit symbol constellations, as well as the derivation of closed-form expressions for large oversampling ratios and for high signal-to-noise ratios of the channel.
116

Demand-side management in office buildings in Kuwait through an ice-storage assisted HVAC system with model predictive control

Al-Hadban, Yehya January 2005 (has links)
Examining methods for controlling the electricity demand in Kuwait was the main objective and motivation of this researchp roject. The extensiveu se of air-conditioning for indoor cooling in office and large commercial buildings in Kuwait and the Gulf States represents a major part of the power and electricity consumption in such countries. The rising electricity generation cost and growing rates of consumption continuously demand the construction new power plants. Devising and enforcing Demand-SideM anagemen(t DSM) in the form of energye fficient operations trategies was the response of this research project to provide a means to rectify this situation using the demand-side management technique known as demand levelling or load shifting. State of the art demand-sidem anagementte chniquesh ave been examined through the developmenot f a model basedp redictive control optimisations trategyf or an integrateda ndm odulara pproachto the provisiono f ice thermals torage. To evaluate the potential of ice-storage assisted air-conditioning systems in flattening the demand curve at peak times during the summer months in Kuwait, a model of a Heating, Ventilation, and Air-conditioning (HVAC) plant was developed in Matlab. The model engaged the use of model based predictive control (MPQ) as an optimisation tool for the plant as a whole. The model with MPC was developed to chose and decide on which control strategy to operate the integrated ice-storage HVAC plant. The model succeeded in optimising the operation of the plant and introduced encouraging improvement of the performance of the system as a whole. The concept of the modular ice-storage system was introduced through a control zoning strategy based on zonal orientation. It is believed that such strategy could lead to the modularisation of ice-storage systems. Additionally, the model was examined and tested in relation to load flattening and demonstrated promising enhancement in the shape of the load curve and demonstrated flattened demand curves through the employed strategy. When compared with measured data from existing buildings, the model showed potential for the techniques utilised to improve the load factor for office buildings.
117

Data aggregation in sensor networks

Kallumadi, Surya Teja January 1900 (has links)
Master of Science / Department of Computing and Information Sciences / Gurdip Singh / Severe energy constraints and limited computing abilities of the nodes in a network present a major challenge in the design and deployment of a wireless sensor network. This thesis aims to present energy efficient algorithms for data fusion and information aggregation in a sensor network. The various methodologies of data fusion presented in this thesis intend to reduce the data traffic within a network by mapping the sensor network application task graph onto a sensor network topology. Partitioning of an application into sub-tasks that can be mapped onto the nodes of a sensor network offers opportunities to reduce the overall energy consumption of a sensor network. The first approach proposes a grid based coordinated incremental data fusion and routing with heterogeneous nodes of varied computational abilities. In this approach high performance nodes arranged in a mesh like structure spanning the network topology, are present amongst the resource constrained nodes. The sensor network protocol performance, measured in terms of hop-count is analysed for various grid sizes of the high performance nodes. To reduce network traffic and increase the energy efficiency in a randomly deployed sensor network, distributed clustering strategies which consider network density and structure similarity are applied on the network topology. The clustering methods aim to improve the energy efficiency of the sensor network by dividing the network into logical clusters and mapping the fusion points onto the clusters. Routing of network information is performed by inter-cluster and intra-cluster routing.
118

Green Buildings : Exploring performance and thresholds

Bonde, Magnus January 2016 (has links)
The overall aim of this research project is to study green/energy-efficient real estate from an economic perspective. The thesis summarizes the results from five different studies with a connection to green/energy-efficient real estate.The aim of the first paper (paper A) is to study how tenants perceive the indoor environment in green-rated premises, and to compare these results with tenants’ perception of a conventional building’s indoor environment. The main result is that the tenants in the green-rated building are more satisfied with the indoor environment than the tenants in the conventional building.Papers B and C assess whether energy efficiency has an impact on buildings’ income and market values using Swedish real-estate data. The key result is that although there is a small impact on building-related income, this does not seem to translate into a higher market value.The last two papers included in this thesis study hindrances to a more energy-efficient building sector. In paper D, two office buildings are used as baseline cases to provide insights into the difficulties that can arise when trying to upgrade a building to make it more energy efficient. The results indicate that changing existing leases is a prohibitive process and that it is often difficult to evaluate the final impact of an energy upgrade. The last paper focuses on why it may be rational to postpone green refurbishments even if they are profitable. The main result is that it may be rational to postpone such refurbishments. However, by introducing different financial penalties and/or subsidies, these investments could be triggered today.To sum up, the results indicate that green buildings are preferred by tenants, but that there still appear to be economic barriers to a greener building sector. / Det övergripande syftet med denna avhandling är att studera grön/energieffektiva byggnader ur ett ekonomiskt perspektiv. Avhandlingen består av en kappa och fem separata studier, vilka belyser tre olika forskningsfrågor. Syftet med den första studien är att studera hur hyresgäster upplever inomhusmiljön i gröna byggnader. I studien jämförs inomhusmiljön i en grön byggnad med inomhusmiljön i en likvärdig konventionell byggnad. Resultatet visar, på det stora hela, att hyresgästerna är mer nöjda med inomhusmiljön i den gröna byggnaden. De nästföljande studierna, B respektive C, undersöker om byggnadens energiprestanda har någon inverkan på dess hyra respektive marknadsvärde. Resultaten visar på en liten signifikant hyrespåverkan, dock verkar denna inte ha någon effekt på byggnadernas marknadsvärdebedömningar. Skälet till detta kan vara att hyrespremien anses för liten för att ha någon signifikant inverkan på byggnadens marknadsvärde, alternativt att fastighetsvärderare inte beaktar energiprestanda när en fastighet värderas. De två sista studierna studerar varför vissa, tillsynes lönsamma, energiinvesteringar inte genomförs. Resultaten från studie D visar på svårigheterna med att ingå ett samarbetsavtal (för att eliminera felaktiga incitament) mellan hyresgäst och hyresvärd. Sådana avtal tar lång tid att förhandla fram och det uppkommer ofta svårigheter med att utvärdera de tänkta energiinvesteringarnas ekonomiska utfall. Studie E utgår ifrån en realoptionsmodell, vilken används för att utvärdera när ”gröna” renoveringar bör genomföras i en befintlig byggnad. Studien visar att det kan vara rationellt att vänta trots att investeringen idag är lönsam. Vidare visar resultaten att det är möjligt att via byggsubventioner/finansiella ”straff” påverka aktörer att tidigarelägga energieffektiviseringsåtgärder.  Dock är det viktigt att dessa utformas korrekt så att det inte skapar några snedvridna incitament. Övergripande visar resultaten att gröna byggnader är att föredra ur ett brukarperspektiv men att det fortfarande finns ekonomiska hinder för en mer hållbar byggsektor. Nyckelord: gröna byggnader, energieffektiva byggnader, EPC, inomhusmiljö, Realoptioner, fastighetsekonomi. / <p>QC 20160407</p>
119

Integration of Phase Change Materials in Commercial Buildings for Thermal Regulation and Energy Efficiency

Malekzadeh, Fatemeh January 2015 (has links)
One of prospective procedures of absorbing thermal energy and releasing it during the required time is the application of phase change materials known as PCMs in building envelopes. High thermal energy storage (TES) materials has been a technology that effects the energy efficiency of a building by contributing in using onsite resources and reducing cooling or heating loads. Currently, many TES systems are emerging and contributing in building assemblies, however using an appropriate type of TES in a specific building and climate requires an in-depth knowledge of their properties. This research aims to provide a thorough review of a broad range of thermal energy storage technologies including their potential application in buildings. Subsequently, a comparative study and simulation between a basecase and an optimized model by PCM is thoroughly considered to understand the effect of high thermal storage building's shell on energy efficiency and indoor thermal comfort. Specifically this study proposes that the incorporation of PCM into glazing system as a high thermal capacity system will improve windows thermal performance and thermal capacity to varying climatic conditions. The generated results by eQUEST energy modeling software demonstrates approximately 25% reduction in cooling loads during the summer and 10% reduction in heating loads during the winter for optimized office building by PCM in hot arid climate of Arizona. Besides, using PCM in glazing system will reduce heat gain through the windows by conduction phenomenon. The hourly results indicates the effect of PCM as a thermal energy storage system in building envelopes for building's energy efficiency and thermal regulation. However, several problems need to be tackled before LHTES can reliably and practically be applied. We conclude with some suggestions for future work.
120

Secure Routing in Intelligent Device-to-Device Communications

Elsemary, Hadeer 16 September 2016 (has links)
No description available.

Page generated in 0.082 seconds