• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • Tagged with
  • 20
  • 20
  • 20
  • 8
  • 7
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo da correlação da densidade mineral óssea obtida pelo método de absorciometria radiográfica com a resistência óssea do terceiro metacarpiano de eqüinos submetido a ensaios biomecânicos / Correlation study between bone mineral density determined by radiographic absorptiometry and bone resistance of equine third metacarpal bone submitted to biomechanial testings

Frazão, Paulo José Riccio 06 August 2008 (has links)
A fundamentação de métodos diagnósticos precoces na ortopedia de eqüinos é de extrema importância clínica, cirúrgica e econômica. O presente estudo teve como objetivo estudar a correlação da densidade mineral óssea do terceiro metacarpiano de eqüinos, obtida pelo método de absorciometria radiográfica, com a resistência dos mesmos quando submetidos a ensaios biomecânicos de compressão e flexão. Utilizaram-se trinta pares de osso terceiro metacarpiano de eqüinos adultos, os quais foram dissecados, radiografados, analisados pelo método de absorciometria radiográfica, submetidos ao estudo tomográfico e a ensaios biomecânicos. Através dos dados obtidos não se observou correlação significativa entre os valores de densidade óptica radiográfica e as propriedades biomecânicas do osso terceiro metacarpiano. Concluiu-se que não se pode inferir que os valores de densidade óssea obtidos pela absorciometria radiográfica do osso terceiro metacarpiano de um eqüino tenha correlação com a capacidade deste osso de absorver cargas de compressão e flexão. / The complete knowledge about non-invasive methods for early disgnostics in equine orthopedy is economicaly important. This experiment has studied the correlation between bone mineral density determined by radiographic absorptiometry and bone resistance of equine third metacarpal bone submitted to both compression and flexion testings. Thirty pairs of third metacarpal bone of adult horses were collected, dissected, radiographed, analysed by the radiographic absorptiometry technique, and submitted to tomographic study and biomechanical testings. The results have shown there is no significant correlation between radiographic bone density values and biomechanical properties of the third metacarpal bone. Therefore, it has been concluded bone mineral density of the third metacarpal bone determined by radiographic absorptiometry do not predict bone capacity to resist compression and flexion loads.
12

Estudo da correlação da densidade mineral óssea obtida pelo método de absorciometria radiográfica com a resistência óssea do terceiro metacarpiano de eqüinos submetido a ensaios biomecânicos / Correlation study between bone mineral density determined by radiographic absorptiometry and bone resistance of equine third metacarpal bone submitted to biomechanial testings

Paulo José Riccio Frazão 06 August 2008 (has links)
A fundamentação de métodos diagnósticos precoces na ortopedia de eqüinos é de extrema importância clínica, cirúrgica e econômica. O presente estudo teve como objetivo estudar a correlação da densidade mineral óssea do terceiro metacarpiano de eqüinos, obtida pelo método de absorciometria radiográfica, com a resistência dos mesmos quando submetidos a ensaios biomecânicos de compressão e flexão. Utilizaram-se trinta pares de osso terceiro metacarpiano de eqüinos adultos, os quais foram dissecados, radiografados, analisados pelo método de absorciometria radiográfica, submetidos ao estudo tomográfico e a ensaios biomecânicos. Através dos dados obtidos não se observou correlação significativa entre os valores de densidade óptica radiográfica e as propriedades biomecânicas do osso terceiro metacarpiano. Concluiu-se que não se pode inferir que os valores de densidade óssea obtidos pela absorciometria radiográfica do osso terceiro metacarpiano de um eqüino tenha correlação com a capacidade deste osso de absorver cargas de compressão e flexão. / The complete knowledge about non-invasive methods for early disgnostics in equine orthopedy is economicaly important. This experiment has studied the correlation between bone mineral density determined by radiographic absorptiometry and bone resistance of equine third metacarpal bone submitted to both compression and flexion testings. Thirty pairs of third metacarpal bone of adult horses were collected, dissected, radiographed, analysed by the radiographic absorptiometry technique, and submitted to tomographic study and biomechanical testings. The results have shown there is no significant correlation between radiographic bone density values and biomechanical properties of the third metacarpal bone. Therefore, it has been concluded bone mineral density of the third metacarpal bone determined by radiographic absorptiometry do not predict bone capacity to resist compression and flexion loads.
13

Avaliação  da estabilidade primária de diferentes implantes, por meio de ensaios biomecânicos, análises radiográficas, tomográficas, histomorfométricas. Estudo in vitro / Evaluation of primary implant stability by biomechanical testing, radiographic, CT, histomorphometric analysis. In vitro study

Dantas, Carolina Delmondes Freitas 22 August 2016 (has links)
A estabilidade primária, após a instalação do implante, é uma condição essencial para a aplicação de carga imediata, situação clínica cada vez mais desejada por profissionais e pacientes. O presente estudo tem como objetivo avaliar a estabilidade primária de cinco diferentes implantes instalados em bases ósseas padronizadas de osso suíno e blocos de poliuretano (modelos in vitro), por meio de ensaios biomecânicos e análise de imagens (microtomográficas e histomorfométricas). Para certificação e padronização dos cilindros de osso suíno, foram realizadas tomadas radiográficas digitais, determinando cilindros ósseos de alta e baixa densidades. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: Densidade Óssea Tridimensional (BV/TV); Separação Trabecular (Tb.Sp); Porcentagem de Poros Abertos (Po.Op); Porcentagem de Poros Fechados (Po.Cl) e Porcentagem de Porosidade Total (Po.Tot). Esses parâmetros foram avaliados em quatro níveis ósseos (N1 interno às roscas do implante a ser instalado; N2 adjacente ao final das roscas até 0,5 mm destas; N3 distante 0,5 mm a 1,5 mm do final das roscas; N4 área óssea de 0 a 0,5mm da apical do implante). Depois disso, foram selecionados 50 implantes de 5 diferentes modelos, divididos em 5 grupos com 10 implantes cada: Grupo 1 (G1): implantes Xive Plus inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 2 (G2): implantes Ankylos inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 3 (G3): implantes Bone Level inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 4 (G4): implantes AlvimCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 5 (G5): implantes DriveCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5). A instalação de todos implantes seguiu o protocolo recomendado pelos fabricantes, sendo realizada a medida do torque de inserção (IT) e logo após a análise de Coeficiente de Estabilidade do Implante - ISQ (avaliação por Frequência de ressonância - RFA). Após a instalação dos implantes nos cilindros ósseos, estes foram submetidos a nova análise tridimensional com os mesmos parâmetros e níveis ósseos. Para as análises nos blocos de poliuretano, foram seccionados 50 blocos de alta e baixa densidade (D1 e D3, respectivamente), e inseridos 50 implantes individualmente nos blocos, utilizando 10 de cada e divididos em 5 grupos: Grupo 6 (G6): implantes Xive Plus inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 7 (G7): implantes Ankylos inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 8 (G8): implantes Bone Level inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes AlvimCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes DriveCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5). Após a inserção dos implantes, estes também foram analisados com relação ao torque de inserção, frequência de ressonância e através do ensaio de arrancamento. Os ensaios biomecânicos mostraram que os implantes instalados no G4 (AlvimCM) e G5 (DriveCM) tiveram maior valores de IT e de RFA em ambas as bases ósseas suínas. Nos blocos de poliuretano, tiveram resultados semelhantes entre as bases ósseas para quase todos os implantes nos testes IT e RFA, havendo um maior valor no ensaio de arrancamento para os implantes Bone Level (G8). Os resultados para todas os parâmetros avaliados por MicroCT mostraram que as diferenças dos valores pós e pré-inserção dos implantes revelaram significância estatística principalmente para G4 e G5 em relação aos outros grupos. A análise histomorfométrica mostrou maiores valores de compactação óssea e de Contato Osso-Implante (BIC) para G2, G4 e G5. Para todas as análises de imagem foi observada uma tendência de maior compactação nos N1, N2 e N4; no N3 não houve um aumento significativo da condensação óssea pós-inserção do implante. Concluiu-se que os implantes AlvimCM e DriveCM mostraram melhores resultados nos testes biomecânicos e em relação ao aumento da densidade óssea ao redor do implante, avaliada pelos métodos de imagem, e que estes resultados estiveram correlacionados à estabilidade primária exibida pós-inserção. Os resultados histomorfométricos confirmaram os resultados obtidos pela análise microtomográfica, demonstrando assim a validade do método 3D de análise por imagem. / The primary stability, after implant installation, is an essential condition for the application of immediate loading, clinical situation increasingly desired by professionals and patients. The present study has the objective of evaluating the primary stability of five different implants installed in standard bone bases of swine bone and polyurethane blocks (in vitro models), through biomechanical tests and image analysis (microtomographic and histomorphometric). For the certification and standardization of the swine bone cylinders, digital radiographs were taken, determining bone cylinders of high and low density. After the certification, computerized microtomographies of the bone cylinders were performed for three-dimensional analysis of images prior to implant installation, evaluating the following parameters: Three-dimensional Bone Density (BV / TV); Trabecular Separation (Tb.Sp); Percent of Open Pore (Po.Op); Percent of Closed Pores (Po.Cl) and Percentage of Total Porosity (Po.Tot). These parameters were evaluated in four bone levels (N1 - internal to the threads of the implant to be installed, N2 - adjacent to the end of the threads up to 0.5 mm of these, N3 - distant 0.5 mm to 1.5 mm from the end of the threads ; N4 - bone area 0 to 0.5 mm from the apical of the implant). After that, 50 implants of 5 different models were divided into 5 groups with 10 implants each: Group 1 (G1): Xive Plus implants inserted into high (n = 5) and low density (n = 5) ; Group 2 (G2): Ankylos implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 3 (G3): Bone Level implants inserted into bone cylinders of high (n = 5) and low density (n = 5); Group 4 (G4): AlvimCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 5 (G5): DriveCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders. The implantation of all implants followed the protocol recommended by the manufacturers, and the measurement of the insertion torque (IT) and soon after the analysis of Implantation Stability Coefficient (ISQ (evaluation by Frequency of Resonance - RFA)). After the implants were installed in the bone cylinders, they were submitted to a new three-dimensional analysis with the same parameters and bone levels. 50 blocks of high and low density (D1 and D3, respectively), and 50 implants were inserted individually into the blocks, using 10 of each and divided into 5 groups: Group 6 (G6): implants Xive Plus inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 7 (G7): Ankylos implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 8 (G8): Bone Level implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): AlvimCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): DriveCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5). After insertion of the implants, these were also analyzed with respect to the insertion torque, resonance frequency and through the pullout test. The biomechanical tests showed that the implants installed in G4 (AlvimCM) and G5 (DriveCM) had higher IT and RFA values in both porcine bone bases. In the polyurethane blocks, similar results were found between the bone bases for almost all implants in the IT and RFA tests, with a higher value in the pullout test for Bone Level (G8) implants. The results for all the parameters evaluated by MicroCT showed that the differences in the post-insertion and pre-insertion values of the implants revealed statistical significance mainly for G4 and G5 in relation to the other groups. The histomorphometric analysis showed higher Bone Compaction and Bone Implant (BIC) compaction values for G2, G4 and G5. For all the image analyzes a tendency of greater compaction was observed in N1, N2 and N4; in N3 there was no significant increase in bone post-insertion implant condensation. It was concluded that the AlvimCM and DriveCM implants showed better results in the biomechanical tests and in relation to the increase of the bone density around the implant, evaluated by the imaging methods, and that these results were correlated to the primary stability exhibited post-insertion. The histomorphometric results confirmed the results obtained by the microtomographic analysis, thus demonstrating the validity of the 3D image analysis method.
14

Estudo biomecânico de tração (ex-vivo) em osteotomia da tuberosidade tibial de cães estabilizada com placa fixa por \"garfo\" ou parafuso / Biomechanical study of traction (ex-vivo) on the tibial tuberosity osteotomy in dogs stabilized with plates fixed by \"fork\" or screws

Ito, Kelly Cristiane 09 November 2012 (has links)
Avanço da tuberosidade tibial (ATT) é uma das técnicas para tratamento da ruptura do ligamento cruzado em cães desenvolvida por Montavon, Damur e Tepic (2002). O sucesso da técnica em reduzir ou eliminar as forças de deslocamento cranial da tíbia em joelhos com ruptura do ligamento cruzado cranial tem sido documentado em estudos experimentais e clínicos. No período pós-operatório a técnica, a falha do implante é relatada em 1 a 5% dos membros pélvicos operados. Este número foi atribuído a erro de técnica ou desenho inicial do implante que foi considerado insuficiente. Com objetivo de comparar a resistência biomecânica entre duas diferentes placas de ATT e minimizar a incidência de falhas de implante, foram realizados ensaios biomecânicos em 10 pares de membros pélvicos de cadáveres cães, no membro pélvico direito placa fixa por garfo e no membro pélvico esquerdo placa fixa por parafusos. Os ensaios foram realizados utilizando-se máquina universal de ensaios mecânicos Kratos® modelo 5002, dotada de célula de carga de 3000N com uma velocidade de ensaio de 20 mm/min. O parâmetro força e os gráficos gerados foram gravados por meio de sistema de aquisição analógica TRACOMP-W95 (TRCV61285). A média da carga máxima até a falha foi de 128,70 Kg/F (mínimo 104,55 Kg/F e máximo 151,80 Kg/F) e de 141,99 Kg/F (mínimo 111,60 Kg/F e máximo 169,65 Kg/F) no grupo utilizando \"garfo\" e parafusos respectivamente. O desvio padrão dos grupos \"garfo\" e parafuso foi baixo, 12,99 e 17,21 respectivamente. Foi encontrada diferença significativa (p = 0,0309) entre as médias dos grupos. / Tibial tuberosity advancement (TTA) is one of the techniques for treatment of cruciate ligament rupture in dogs developed by Montavon, Damur and Tepic (2002). The success of the technique in reducing or eliminating the forces of cranial tibial displacement in knees with ruptured cranial cruciate ligament as been documented in experimental and clinical studies. In the post-operative technique, implant failure is reported in 1-5% of hindlimbs operated. This number was attributed to technical error or the initial design of the implant that was considered insufficient. To compare the biomechanical strength between two different plates ATT and minimize the incidence of implant failures, biomechanical tests were performed on 10 pairs of hindlimbs cadaver dogs, the right hindlimb fixed plate and a fork in the left pelvic limbplate fixed by screws. As says were performed using a universal mechanical testing Kratos ® model 5002, equipped with a load cell of 3000N with a test speed of 20 mm / min. The strength parameter and graphs generated were recorded via analog acquisition system TRACOMP-W95 (TRCV61285). The mean load to failure was 128.70 kg/F (minimum 104.55 Kg and maximum 151.80 Kg/F) and 141.99 Kg/F (minimum 111.60 Kg/F and maximum 169.65 Kg/F) in the group using \"fork\" and screws respectively. The standard deviation of the groups \"fork\" and bolt was low, 12.99 and 17.21 respectively. Significant difference (p = 0.0309) between the means of the groups.
15

Avaliação  da estabilidade primária de diferentes implantes, por meio de ensaios biomecânicos, análises radiográficas, tomográficas, histomorfométricas. Estudo in vitro / Evaluation of primary implant stability by biomechanical testing, radiographic, CT, histomorphometric analysis. In vitro study

Carolina Delmondes Freitas Dantas 22 August 2016 (has links)
A estabilidade primária, após a instalação do implante, é uma condição essencial para a aplicação de carga imediata, situação clínica cada vez mais desejada por profissionais e pacientes. O presente estudo tem como objetivo avaliar a estabilidade primária de cinco diferentes implantes instalados em bases ósseas padronizadas de osso suíno e blocos de poliuretano (modelos in vitro), por meio de ensaios biomecânicos e análise de imagens (microtomográficas e histomorfométricas). Para certificação e padronização dos cilindros de osso suíno, foram realizadas tomadas radiográficas digitais, determinando cilindros ósseos de alta e baixa densidades. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: Densidade Óssea Tridimensional (BV/TV); Separação Trabecular (Tb.Sp); Porcentagem de Poros Abertos (Po.Op); Porcentagem de Poros Fechados (Po.Cl) e Porcentagem de Porosidade Total (Po.Tot). Esses parâmetros foram avaliados em quatro níveis ósseos (N1 interno às roscas do implante a ser instalado; N2 adjacente ao final das roscas até 0,5 mm destas; N3 distante 0,5 mm a 1,5 mm do final das roscas; N4 área óssea de 0 a 0,5mm da apical do implante). Depois disso, foram selecionados 50 implantes de 5 diferentes modelos, divididos em 5 grupos com 10 implantes cada: Grupo 1 (G1): implantes Xive Plus inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 2 (G2): implantes Ankylos inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 3 (G3): implantes Bone Level inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 4 (G4): implantes AlvimCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 5 (G5): implantes DriveCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5). A instalação de todos implantes seguiu o protocolo recomendado pelos fabricantes, sendo realizada a medida do torque de inserção (IT) e logo após a análise de Coeficiente de Estabilidade do Implante - ISQ (avaliação por Frequência de ressonância - RFA). Após a instalação dos implantes nos cilindros ósseos, estes foram submetidos a nova análise tridimensional com os mesmos parâmetros e níveis ósseos. Para as análises nos blocos de poliuretano, foram seccionados 50 blocos de alta e baixa densidade (D1 e D3, respectivamente), e inseridos 50 implantes individualmente nos blocos, utilizando 10 de cada e divididos em 5 grupos: Grupo 6 (G6): implantes Xive Plus inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 7 (G7): implantes Ankylos inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 8 (G8): implantes Bone Level inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes AlvimCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes DriveCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5). Após a inserção dos implantes, estes também foram analisados com relação ao torque de inserção, frequência de ressonância e através do ensaio de arrancamento. Os ensaios biomecânicos mostraram que os implantes instalados no G4 (AlvimCM) e G5 (DriveCM) tiveram maior valores de IT e de RFA em ambas as bases ósseas suínas. Nos blocos de poliuretano, tiveram resultados semelhantes entre as bases ósseas para quase todos os implantes nos testes IT e RFA, havendo um maior valor no ensaio de arrancamento para os implantes Bone Level (G8). Os resultados para todas os parâmetros avaliados por MicroCT mostraram que as diferenças dos valores pós e pré-inserção dos implantes revelaram significância estatística principalmente para G4 e G5 em relação aos outros grupos. A análise histomorfométrica mostrou maiores valores de compactação óssea e de Contato Osso-Implante (BIC) para G2, G4 e G5. Para todas as análises de imagem foi observada uma tendência de maior compactação nos N1, N2 e N4; no N3 não houve um aumento significativo da condensação óssea pós-inserção do implante. Concluiu-se que os implantes AlvimCM e DriveCM mostraram melhores resultados nos testes biomecânicos e em relação ao aumento da densidade óssea ao redor do implante, avaliada pelos métodos de imagem, e que estes resultados estiveram correlacionados à estabilidade primária exibida pós-inserção. Os resultados histomorfométricos confirmaram os resultados obtidos pela análise microtomográfica, demonstrando assim a validade do método 3D de análise por imagem. / The primary stability, after implant installation, is an essential condition for the application of immediate loading, clinical situation increasingly desired by professionals and patients. The present study has the objective of evaluating the primary stability of five different implants installed in standard bone bases of swine bone and polyurethane blocks (in vitro models), through biomechanical tests and image analysis (microtomographic and histomorphometric). For the certification and standardization of the swine bone cylinders, digital radiographs were taken, determining bone cylinders of high and low density. After the certification, computerized microtomographies of the bone cylinders were performed for three-dimensional analysis of images prior to implant installation, evaluating the following parameters: Three-dimensional Bone Density (BV / TV); Trabecular Separation (Tb.Sp); Percent of Open Pore (Po.Op); Percent of Closed Pores (Po.Cl) and Percentage of Total Porosity (Po.Tot). These parameters were evaluated in four bone levels (N1 - internal to the threads of the implant to be installed, N2 - adjacent to the end of the threads up to 0.5 mm of these, N3 - distant 0.5 mm to 1.5 mm from the end of the threads ; N4 - bone area 0 to 0.5 mm from the apical of the implant). After that, 50 implants of 5 different models were divided into 5 groups with 10 implants each: Group 1 (G1): Xive Plus implants inserted into high (n = 5) and low density (n = 5) ; Group 2 (G2): Ankylos implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 3 (G3): Bone Level implants inserted into bone cylinders of high (n = 5) and low density (n = 5); Group 4 (G4): AlvimCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 5 (G5): DriveCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders. The implantation of all implants followed the protocol recommended by the manufacturers, and the measurement of the insertion torque (IT) and soon after the analysis of Implantation Stability Coefficient (ISQ (evaluation by Frequency of Resonance - RFA)). After the implants were installed in the bone cylinders, they were submitted to a new three-dimensional analysis with the same parameters and bone levels. 50 blocks of high and low density (D1 and D3, respectively), and 50 implants were inserted individually into the blocks, using 10 of each and divided into 5 groups: Group 6 (G6): implants Xive Plus inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 7 (G7): Ankylos implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 8 (G8): Bone Level implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): AlvimCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): DriveCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5). After insertion of the implants, these were also analyzed with respect to the insertion torque, resonance frequency and through the pullout test. The biomechanical tests showed that the implants installed in G4 (AlvimCM) and G5 (DriveCM) had higher IT and RFA values in both porcine bone bases. In the polyurethane blocks, similar results were found between the bone bases for almost all implants in the IT and RFA tests, with a higher value in the pullout test for Bone Level (G8) implants. The results for all the parameters evaluated by MicroCT showed that the differences in the post-insertion and pre-insertion values of the implants revealed statistical significance mainly for G4 and G5 in relation to the other groups. The histomorphometric analysis showed higher Bone Compaction and Bone Implant (BIC) compaction values for G2, G4 and G5. For all the image analyzes a tendency of greater compaction was observed in N1, N2 and N4; in N3 there was no significant increase in bone post-insertion implant condensation. It was concluded that the AlvimCM and DriveCM implants showed better results in the biomechanical tests and in relation to the increase of the bone density around the implant, evaluated by the imaging methods, and that these results were correlated to the primary stability exhibited post-insertion. The histomorphometric results confirmed the results obtained by the microtomographic analysis, thus demonstrating the validity of the 3D image analysis method.
16

Efeito da associação de dieta hiperlipídica e hipoestrogenismo sobre a integridade óssea mandibular de ratas / Mandible, fat diet, ovariectomy, physic parameters, biomechanical testing in rats

Silvio Sandro Cornélio 05 January 2010 (has links)
O aumento da expectativa de vida permite a mulher viver muitos anos após a menopausa. Além disso, a mudança nos hábitos alimentares da sociedade moderna tem determinado o aumento da incidência de obesidade e sobrepeso na população. Essas duas situações têm despertado o interesse da comunidade científica, visto as repercussões deletérias que podem ocorrer com o organismo. O objetivo deste estudo foi avaliar o efeito da deficiência de estrogênio associado à dieta hiperlipídica sobre a integridade óssea da mandíbula de ratas. Para tal, ratas Wistar jovens foram avaliadas por citologia vaginal e aos 90 dias de idade, divididas em 4 grupos: Controle (C4%), Controle hiperlipídica19% (C19%), Ovariectomizada 4% (OVX4%) e Ovariectomizada19% (OVX19%). O período experimental começou com a castração (90 d de idade), seguido da alimentação com dieta hiperlipídica, por 30 dias. Ao final desse período, após anestesia, o sangue foi coletado para análise sérica de cálcio, fósforo, fosfatase alcalina e estradiol. Mandíbulas, vértebras L4 e fêmures foram removidos e preparados para análise das propriedades físicas e biomecânicas. Não foram observadas diferenças na ingestão alimentar, no comprimento corporal nem nas medidas ósseas dos grupos. O cálcio sérico diminuiu significativamente nos grupos castrados. O fósforo diminuiu enquanto, a fosfatase alcalina aumentou em todos os grupos, quando comparados ao C4%. Dentre os parâmetros físicos avaliados alguns apresentaram diferenças entre os grupos. Nas vértebras L4, os pesos imersos e úmidos aumentaram com a castração e com a dieta hiperlipídica, enquanto, os percentuais de material orgânico e mineral diminuíram. Nas mandíbulas, os pesos imersos e úmidos e a densidade óssea aumentaram com a castração, mas diminuem com a associação castração/dieta hiperlipídica. O volume ósseo e o percentual de água diminuíram com a ingestão de dieta hiperlipídica. Nenhuma alteração foi observada nos fêmures. Nas cinzas das mandíbulas os percentuais de magnésio apresentaram-se significativamente aumentados em todos os grupos. Mas, os de cálcio e fósforo não variaram. Nos testes biomecânicos de vértebra L4 e fêmur não foram encontradas diferenças entre os grupos. No entanto, na mandíbula os grupos alimentados com dieta hiperlipídica apresentaram menor resistência à tensão aplicada, em relação aos grupos de dieta normolipídica. Ficou evidenciado nessas ratas que a deficiência de esteróides sexuais associada à dieta hiperlipídica influencia de forma negativa a integridade óssea mandibular. / Increased life expectancy of women allows her to live many years after menopause. On the other hand, the western way of life has brought about an increased incidence of obesity and overweight to people. These two situations have attracted the interest of the scientific community, given the deleterious consequences that may occur with the body. The aim of this study was to evaluate the effect of estrogen deficiency associated with high-fat diet on the mandibular bone integrity of rats. Wistar young rats were previously evaluated by vaginal cytology and at 90 days old were divided into 4 groups: control (C4%), Control 19% fat diet (C19%), ovariectomized 4% (OVX4%), ovariectomized and 19% fat diet (OVX 19%). The experimental period started with castration (90 days old) followed by the implementation of high-fat diet for 30 days. At the end of this period, after anesthesia blood was collected for later analysis of serum concentrations of calcium, phosphorus, alkaline phosphatase and estradiol. Mandibular bone, lumbar column L4 and femurs were removed and prepared for physical and biomechanical analysis. There were no differences in food intake, body length or in bone measurements of all groups. Serum calcium decreased significantly in ovariectomized groups. Phosphorus concentrations decreased and alkaline phosphatase increased in all experimental groups, compared to C4%. Among the physical parameters evaluated some differences were showed between the groups. At L4 vertebrae, the immersed and wet weights increased with castration and the high-fat diet, while the percentage of organic material and mineral decreased. In mnadibles, the immersed and wet weights and bone density increased with castration, but decrease with the combination of castration/fat diet. The bone volume and the percentage of water decreased with the intake of fat diet. No changes were observed in the femurs. In the ashes of mandibular bones the percentage of magnesium were significantly increased in all groups. But the calcium and phosphorus did not change. The biomechanical test of the L4 vertebra and femur were not significant differences between the groups. However, in mandibular bone, groups fed with high-fat diet had lower resistance to the applied voltage, compared to normal-fat diet groups. It was evident in these rats that the deficiency of sex steroids associated with high-fat diet negatively influences mandibular bone integrity.
17

Ensaio biomecânico para determinação do diâmetro de barra conectora de polimetilmetacrilato em fixador esquelético externo tipo Ia: no úmero de suínos / Biomechanical test to determination the diameter of the polymethylmethacrylate bar in external skeletal fixator type Ia: in swine humerus

Schmitt, Bernardo 26 February 2014 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / While seemingly inert appearance, bones are highly dynamic structures, which promote formation, resorption, repair and maintenance of homeostasis. Fractures in bones occur when the load applied to a specific bone region exceeds its resilience. The use of external skeletal fixator (ESF) is a method of fairly common internal stabilization, in which connector bars polymethylmethacrylate (PMMA) are used without criterion in diameter. In these cases, it can break if it gets too thin or too heavy and uncomfortable when bulky. The aim of this study was to test biomechanical through axial compression and bending, considering different connector bar diameter PMMA correlated to bone diameter for use to type Ia ESF. For this, it was collected 24 swine humerus to make measurements of length, diameter, circumference and testing biomechanical. After the bars confected with 1.5 times the average diameter of the bone (group I), the same diameter bone (group II) and 0.5 times the diameter of the bone (group III). The results obtained, it was observed that the connector bars in group II were more resistant than the bones in the compression test. In the bending test, the bones resisted flexion strength when compared to group III. The group II was 4.3 times more resistant than Group III in the same mechanical test. The results allow a direction for making bars PMMA considering bone diameter as a reference. / Apesar do seu aspeto aparentemente inerte, os ossos são estruturas altamente dinâmicas, envolvidas em constante formação, reabsorção, reparação e manutenção da homeostasia. As fraturas ocorrem quando a carga aplicada sobre determinada região do tecido ósseo supera sua capacidade de resistência. A utilização de fixadores esqueléticos externos (FEE) é método de estabilização interna bastante frequente, no qual podem ser utilizadas barras conectoras de polimetilmetacrilato (PMMA) sem preocupação com o diâmetro. Tais barras podem quebrar se ficarem muito delgadas ou tornarem-se desconfortáveis quando volumosas e pesadas. O objetivo deste trabalho foi testar, por meio de ensaio biomecânico de compressão axial e flexão, qual é o diâmetro mais adequado para a barra conectora de PMMA, correlacionado as dimensões da barra com o diâmetro ósseo para FEE tipo Ia. Para tanto, coletaram-se 24 úmeros suínos para a realização de medidas de comprimento, diâmetro, circunferência e os ensaios biomecânicos. Após, confeccionaram-se barras de 1,5 vezes a média do diâmetro ósseo (grupo I), do mesmo diâmetro (grupo II) e 0,5 vez o diâmetro ósseo (grupo III). Com os resultados obtidos ao comparar os valores dos ossos com os dos grupos II e III, verificou-se que as barras conectoras do grupo II mostraram-se mais resistente do que o tecido ósseo no ensaio de compressão. No ensaio de flexão, o osso foi mais resistente à força de flexão quando comparados ao grupo III. O grupo II foi 4,3 vezes mais resistente do que o grupo III nesse mesmo ensaio. O grupo I apresentou secagem incompleta, onde seu comportamento não foi similar com o restante dos grupos, por isso, não participou da estatística do trabalho. Os resultados permitem um direcionamento para confecção de barras de PMMA do mesmo diâmetro ósseo, sendo suficiente para sustentar sem quebrar um FEE tipo Ia.
18

Efeito da associação de dieta hiperlipídica e hipoestrogenismo sobre a integridade óssea mandibular de ratas / Mandible, fat diet, ovariectomy, physic parameters, biomechanical testing in rats

Silvio Sandro Cornélio 05 January 2010 (has links)
O aumento da expectativa de vida permite a mulher viver muitos anos após a menopausa. Além disso, a mudança nos hábitos alimentares da sociedade moderna tem determinado o aumento da incidência de obesidade e sobrepeso na população. Essas duas situações têm despertado o interesse da comunidade científica, visto as repercussões deletérias que podem ocorrer com o organismo. O objetivo deste estudo foi avaliar o efeito da deficiência de estrogênio associado à dieta hiperlipídica sobre a integridade óssea da mandíbula de ratas. Para tal, ratas Wistar jovens foram avaliadas por citologia vaginal e aos 90 dias de idade, divididas em 4 grupos: Controle (C4%), Controle hiperlipídica19% (C19%), Ovariectomizada 4% (OVX4%) e Ovariectomizada19% (OVX19%). O período experimental começou com a castração (90 d de idade), seguido da alimentação com dieta hiperlipídica, por 30 dias. Ao final desse período, após anestesia, o sangue foi coletado para análise sérica de cálcio, fósforo, fosfatase alcalina e estradiol. Mandíbulas, vértebras L4 e fêmures foram removidos e preparados para análise das propriedades físicas e biomecânicas. Não foram observadas diferenças na ingestão alimentar, no comprimento corporal nem nas medidas ósseas dos grupos. O cálcio sérico diminuiu significativamente nos grupos castrados. O fósforo diminuiu enquanto, a fosfatase alcalina aumentou em todos os grupos, quando comparados ao C4%. Dentre os parâmetros físicos avaliados alguns apresentaram diferenças entre os grupos. Nas vértebras L4, os pesos imersos e úmidos aumentaram com a castração e com a dieta hiperlipídica, enquanto, os percentuais de material orgânico e mineral diminuíram. Nas mandíbulas, os pesos imersos e úmidos e a densidade óssea aumentaram com a castração, mas diminuem com a associação castração/dieta hiperlipídica. O volume ósseo e o percentual de água diminuíram com a ingestão de dieta hiperlipídica. Nenhuma alteração foi observada nos fêmures. Nas cinzas das mandíbulas os percentuais de magnésio apresentaram-se significativamente aumentados em todos os grupos. Mas, os de cálcio e fósforo não variaram. Nos testes biomecânicos de vértebra L4 e fêmur não foram encontradas diferenças entre os grupos. No entanto, na mandíbula os grupos alimentados com dieta hiperlipídica apresentaram menor resistência à tensão aplicada, em relação aos grupos de dieta normolipídica. Ficou evidenciado nessas ratas que a deficiência de esteróides sexuais associada à dieta hiperlipídica influencia de forma negativa a integridade óssea mandibular. / Increased life expectancy of women allows her to live many years after menopause. On the other hand, the western way of life has brought about an increased incidence of obesity and overweight to people. These two situations have attracted the interest of the scientific community, given the deleterious consequences that may occur with the body. The aim of this study was to evaluate the effect of estrogen deficiency associated with high-fat diet on the mandibular bone integrity of rats. Wistar young rats were previously evaluated by vaginal cytology and at 90 days old were divided into 4 groups: control (C4%), Control 19% fat diet (C19%), ovariectomized 4% (OVX4%), ovariectomized and 19% fat diet (OVX 19%). The experimental period started with castration (90 days old) followed by the implementation of high-fat diet for 30 days. At the end of this period, after anesthesia blood was collected for later analysis of serum concentrations of calcium, phosphorus, alkaline phosphatase and estradiol. Mandibular bone, lumbar column L4 and femurs were removed and prepared for physical and biomechanical analysis. There were no differences in food intake, body length or in bone measurements of all groups. Serum calcium decreased significantly in ovariectomized groups. Phosphorus concentrations decreased and alkaline phosphatase increased in all experimental groups, compared to C4%. Among the physical parameters evaluated some differences were showed between the groups. At L4 vertebrae, the immersed and wet weights increased with castration and the high-fat diet, while the percentage of organic material and mineral decreased. In mnadibles, the immersed and wet weights and bone density increased with castration, but decrease with the combination of castration/fat diet. The bone volume and the percentage of water decreased with the intake of fat diet. No changes were observed in the femurs. In the ashes of mandibular bones the percentage of magnesium were significantly increased in all groups. But the calcium and phosphorus did not change. The biomechanical test of the L4 vertebra and femur were not significant differences between the groups. However, in mandibular bone, groups fed with high-fat diet had lower resistance to the applied voltage, compared to normal-fat diet groups. It was evident in these rats that the deficiency of sex steroids associated with high-fat diet negatively influences mandibular bone integrity.
19

Estudo biomecânico de tração (ex-vivo) em osteotomia da tuberosidade tibial de cães estabilizada com placa fixa por \"garfo\" ou parafuso / Biomechanical study of traction (ex-vivo) on the tibial tuberosity osteotomy in dogs stabilized with plates fixed by \"fork\" or screws

Kelly Cristiane Ito 09 November 2012 (has links)
Avanço da tuberosidade tibial (ATT) é uma das técnicas para tratamento da ruptura do ligamento cruzado em cães desenvolvida por Montavon, Damur e Tepic (2002). O sucesso da técnica em reduzir ou eliminar as forças de deslocamento cranial da tíbia em joelhos com ruptura do ligamento cruzado cranial tem sido documentado em estudos experimentais e clínicos. No período pós-operatório a técnica, a falha do implante é relatada em 1 a 5% dos membros pélvicos operados. Este número foi atribuído a erro de técnica ou desenho inicial do implante que foi considerado insuficiente. Com objetivo de comparar a resistência biomecânica entre duas diferentes placas de ATT e minimizar a incidência de falhas de implante, foram realizados ensaios biomecânicos em 10 pares de membros pélvicos de cadáveres cães, no membro pélvico direito placa fixa por garfo e no membro pélvico esquerdo placa fixa por parafusos. Os ensaios foram realizados utilizando-se máquina universal de ensaios mecânicos Kratos® modelo 5002, dotada de célula de carga de 3000N com uma velocidade de ensaio de 20 mm/min. O parâmetro força e os gráficos gerados foram gravados por meio de sistema de aquisição analógica TRACOMP-W95 (TRCV61285). A média da carga máxima até a falha foi de 128,70 Kg/F (mínimo 104,55 Kg/F e máximo 151,80 Kg/F) e de 141,99 Kg/F (mínimo 111,60 Kg/F e máximo 169,65 Kg/F) no grupo utilizando \"garfo\" e parafusos respectivamente. O desvio padrão dos grupos \"garfo\" e parafuso foi baixo, 12,99 e 17,21 respectivamente. Foi encontrada diferença significativa (p = 0,0309) entre as médias dos grupos. / Tibial tuberosity advancement (TTA) is one of the techniques for treatment of cruciate ligament rupture in dogs developed by Montavon, Damur and Tepic (2002). The success of the technique in reducing or eliminating the forces of cranial tibial displacement in knees with ruptured cranial cruciate ligament as been documented in experimental and clinical studies. In the post-operative technique, implant failure is reported in 1-5% of hindlimbs operated. This number was attributed to technical error or the initial design of the implant that was considered insufficient. To compare the biomechanical strength between two different plates ATT and minimize the incidence of implant failures, biomechanical tests were performed on 10 pairs of hindlimbs cadaver dogs, the right hindlimb fixed plate and a fork in the left pelvic limbplate fixed by screws. As says were performed using a universal mechanical testing Kratos ® model 5002, equipped with a load cell of 3000N with a test speed of 20 mm / min. The strength parameter and graphs generated were recorded via analog acquisition system TRACOMP-W95 (TRCV61285). The mean load to failure was 128.70 kg/F (minimum 104.55 Kg and maximum 151.80 Kg/F) and 141.99 Kg/F (minimum 111.60 Kg/F and maximum 169.65 Kg/F) in the group using \"fork\" and screws respectively. The standard deviation of the groups \"fork\" and bolt was low, 12.99 and 17.21 respectively. Significant difference (p = 0.0309) between the means of the groups.
20

Efeito de Mananoligossacarídeos sobre parâmetros densitométricos e biomecânicos de ratos em crescimento / MOS effect on densitometry and biomechanical parameters of growing rats

Barbosa, Leandro Kefalás 09 April 2015 (has links)
Made available in DSpace on 2016-07-18T17:53:16Z (GMT). No. of bitstreams: 1 Leandro Barbosa.pdf: 680328 bytes, checksum: 22ee01e97ffce340763c0803b4b252c2 (MD5) Previous issue date: 2015-04-09 / The objective of this study is to evaluate the effect of manann oligosaccharides (MOS) prebiotics on densitometry parameters of the femur by means of bone densitometry and biomechanical test in rats. 144 growing male rats were used, 23 days old, and 36.7 ± 0.6 grams of body weight were divided into 04 experimental groups (n = 36) and kept in individual cages during the experimental period of 56 days: Group Control (GC); Mos Group 1 (GM1); Mos Group 2 (GM2); and Group 3 Mos (GM3). Densitometric analysis and biomechanical testing of bone mineral content were conducted in four stages: 14, 28, 42 and 56 days after beginning the experiment. Simple linear regressions were adjusted data pairs situation, time of collection (every 14 days) and results of bone mineral content parameters (BMC), bone mineral density (BMD), area (A), energy, maximum strength and stiffness. The regressions set of treatments for each parameter were compared in pairs by the intercept and slope of the straight and revealed significant differences between treatments (P <0.0125) in the area parameters, energy absorbed to the maximum strength and maximum strength. The slope of the lines was higher in groups supplemented with MOS compared to the CG. MOS intake increased bone mineralization, which, in turn, increased the resistance to fracture of the femur in all the biomechanical properties and densitometric studied, perhaps due to an increase in the intestinal absorption of nutrients in rats. Given the beneficial results of this study with growing rats as experimental model, it is suggested that this functional food can be used as a food component enhancing bone health. / O objetivo deste estudo é avaliar o efeito dos aditivos prebióticos do tipo mananoligossacarídeos (MOS) sobre os parâmetros densitométricos e biomecânicos, por meio da densitometria óssea e ensaio biomecânico, respectivamente, de fêmures de ratos. Foram utilizados 144 ratos machos em crescimento, com 23 dias de idade e 36,7 ± 0,6 gramas de massa corporal, divididos em 04 grupos experimentais (n=36) e mantidos em gaiolas individuais durante o período experimental de 56 dias: Grupo Controle (GC); Grupo MOS 1 (GM1); Grupo MOS 2 (GM2); e Grupo MOS 3 (GM3). A análise densitométrica e o ensaio biomecânico do conteúdo mineral ósseo foram realizadas em quatro momentos: 14, 28, 42 e 56 dias após o inicio do experimento. Foram ajustadas regressões lineares simples, situação de pares de dados, momento de coleta (a cada 14 dias) e resultados dos parâmetros do conteúdo mineral ósseo (CMO), densidade mineral óssea (DMO), área (A), energia, força máxima e rigidez. As regressões ajustadas dos tratamentos de cada parâmetro foram comparadas duas a duas pelos interceptos e inclinação das retas e revelaram diferenças significativas entre os tratamentos (P<0,0125) nos parâmetros área, energia absorvida até a força máxima e força máxima. A inclinação das retas foi maior nos grupos suplementados com MOS em relação ao GC. A ingestão de MOS resultou em uma maior mineralização óssea, o que, por sua vez, aumentou a resistência à fratura do fêmur em todas as propriedades biomecânicas e densitométricas estudadas, talvez devido a um aumento da absorção intestinal de nutrientes nos ratos. Diante dos benéficos resultados obtidos nesse estudo com ratos em crescimento, como modelo experimental, sugere-se que este alimento funcional possa ser utilizado como um componente alimentar intensificador da saúde óssea, particularmente nos dias de hoje, em que a expectativa de vida aumenta exponencialmente.

Page generated in 0.0623 seconds