• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 49
  • 49
  • 16
  • 14
  • 14
  • 13
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Viabilidade financeira da implantação do projeto de construção da estação de tratamento de esgotos - ETE - do Município de Lençóis Paulista - Estado de São Paulo

Toledo, Julio Cesar Scaramuzzi de [UNESP] 15 July 2008 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:54:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-15. Added 1 bitstream(s) on 2016-04-01T18:00:18Z : No. of bitstreams: 1 000577402.pdf: 782786 bytes, checksum: aeee0a8ffec3f3ca18b09361308fb3bd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta dissertação tem como finalidade, apresentar e comparar dados quantitativos relativos à estação de tratamento de esgotos situada no interior de São Paulo, mais especificamente na cidade de Lençóis Paulista. A proposta do presente trabalho é apresentação de dados financeiros, particularmente retorno e risco do projeto. Dados esses que demonstram também o montante investido, e ainda, as receitas e despesas inerentes ao funcionamento do mesmo. Serão utilizados métodos de análise investimentos tradicionalmente conhecidos como valor presente líquido, taxa interna de retorno e prazo médio de retorno. Para o cálculo da probabilidade de risco do projeto, a distribuição normal será a ferramenta utilizada. É senso comum que um dos maiores fatores de degradação da qualidade da água é justamente a poluição resultante do lançamento dos esgotos sanitários coletados em corpos d'água, o que justifica a necessidade do tratamento desses esgotos, de modo a reduzir a carga poluidora antes de sua disposição final. Segundo dados do Governo Federal apenas 20,2% do esgoto sanitário coletado nos domicílios brasileiros recebem tratamento e só uma pequena parcela tem destinação final sanitariamente adequada no meio (IBGE, 2003). Desta forma, o presente estudo deste problema contemporâneo, demonstrou quantitativamente que a implantação de uma ETE é viável financeiramente, como demonstra os cálculos do valor presente líquido (VPL), taxa interna de retorno (TIR) e o prazo médio de retorno do investimento (payback). Esses métodos de avaliação de investimento foram sensibilizados com uma série que envolve a probabilidade de crescimento populacional, o que possibilitou calcular o risco do projeto, cujo percentual confirma a viabilidade do projeto, em razão do risco calculado ser muito baixo. / This dissertation has the purpose to present and compare quantitative data about waste treatment station, placed in Lençóis Paulista city, in the state of Sao Paulo. At first, this work had the intent to present financial and environmental data, however, the project not in operation, it showed only financial data. These data demonstrate the amount of money invested, as also, the revenues and expenses inherent of operation. This work used the traditional investment analysis method, like net present value, interested rate return and payback. To calculate the project risk probability, it was used normal distribution. The waste water collected is fundamental to guarantee the population's life quality. However, one of the major reason to quality's water degradation is the pollution resulted of throwing waste waters in creeks, rivers and others flow waters which justify the need to treat them, reducing the amount of pollution before their final disposal. According to Brazilian's Government statistics, only 20,2% of waste water from brazilian's homes receives proper treatment, and just a small quantity is returned in sanitary way to the environment. (IBGE, 2003). In such a way, this study esposes a contemporary problem, demonstrating quantitatively, that the implementation of ETE is financially viable, like demonstrated calculation of the net present value (NPV), internal interested rate (IRR), and payback. That investments methods evaluation was sensibility through an probability series about population growth, that make possible calculated the project risk, wich result confirm the viability of the project.
32

Estudo de viroma em água de esgoto influente e efluente na estação de tratamento de esgoto norte em Brasília

Moriya, Nataly Mitie Natsume 01 March 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Biologia, Pós-Graduação em Biologia Microbiana, 2018. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T17:33:47Z No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T19:34:41Z (GMT) No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) / Made available in DSpace on 2018-07-20T19:34:41Z (GMT). No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) Previous issue date: 2018-07-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / A contaminação por patógenos humanos na água de esgoto é um assunto importante, principalmente em locais onde as condições de saneamento não são ideais. A tecnologia de Next Generation Sequencing (NGS) tem sido utilizada em diversos estudos metagenômicos virais (viromas). Além de descrever a diversidade genética, é uma ferramenta útil para analisar o viroma em amostras de esgoto. Apesar do interesse no tratamento de água, a cidade de Brasília não possuí um estudo de censo e informações focado na contaminação viral do Lago Paranoá. Com este propósito, os patógenos humanos astrovírus (HAstV), norovírus (NoV) e sapovírus (SaV) foram selecionados e investigados em amostras de água não-tratada (influente) e tratada (efluente) utilizando o NGS. Amostras de influente e efluente (de março, maio de 2016 e fevereiro de 2017) foram coletadas na estação de tratamento de água de esgoto em Brasília, Brasil. As amostras foram submetidas a processos de extração de RNA e as bibliotecas de cDNA foram sequenciadas através do Illumina HiSeq 2000, com a condição de 100 bases paired-end. Os reads foram trimados através do Trimmomatic e os contigs foram montados com os programas Megahit e Velvet. As sequências foram analisadas por tBLASTX e Megablast, respectivamente, contra o "RefSeq Virus" utilizando o software Geneious v.8.1. Os reads resultantes também foram enviados e analisados na plataforma online Kaiju. Os SaV foram detectados nas seis amostras sequenciadas, HAstV e NoV foram encontrados em todas as amostras, exceto no efluente de maio. Os resultados encontrados foram discutidos e comparados com estudos brasileiros e internacionais. / Contamination of human pathogen in wastewater is an important matter, especially where sanitation is not ideal condition. Next Generation Sequencing (NGS) has been applied in several viral metagenomes (viromes) studies. Besides describing gene diversity, it is a helpful tool to analyze virome in sewage water. Despite the interest in wastewater treatment, Brasilia city lacks a census study and information aiming to assess viral contamination in Paranoa lake. For this purpose, the human pathogens astrovirus (HAstV), norovirus (NoV) and sapovirus (SaV) were selected in untreated (influent) and treated (effluent) wastewater and investigated using NGS technology. Samples of influent and effluent stream (from March, May of 2016 and February of 2017) were collected at the treatment station of wastewater in Brasília, Brazil. Samples were submitted to RNA extraction process and the cDNA libraries were sequenced using Illumina HiSeq 2000 with the condition of 100 base paired-end. The NGS reads were trimmed by Trimmomatic and the contigs were assembled with Megahit and Velvet. The assembled contigs were analyzed by tBLASTX and Megablast, respectively, against RefSeq Virus using Geneious Software v.8.1. Resulted reads were also uploaded and analyzed on Kaiju online platform. SaV were detected in the six sequenced samples, HAstV and NoV were found in all samples except the May untreated water sample. The results found were discussed and compared with Brazilian and international studies.
33

Avaliação da aplicação de lodo de ETA no adensador de lodo de uma ETE de lodos ativados

Peixoto, Gilmar José [UNESP] 30 October 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-10-30Bitstream added on 2014-06-13T18:38:58Z : No. of bitstreams: 1 peixoto_gj_me_ilha.pdf: 3639925 bytes, checksum: e19f2ebbc3c46fda991b86aa7db634e8 (MD5) / No Brasil, existe um problema comum à maioria das comunidades onde o abastecimento público de água é realizado com água superficial e há a necessidade de tratamento. No processo de tratamento ocorre a formação de resíduos na forma de lodo, o qual periodicamente necessita ser descartado do processo. Exceção feita a algumas Estações de Tratamento de Água (ETA), em nível nacional, todas despejam esses resíduos, de forma bruta, sem nenhum tratamento, em corpos de água. O presente trabalho foi realizado com o objetivo de encontrar solução adequada para destinar, de forma correta, o lodo produzido pela ETA da cidade de Presidente Prudente, operada pela Companhia de Saneamento Básico do Estado de São Paulo (SABESP). O estudo baseou-se na premissa em aplicar o lodo da ETA na Estação de Tratamento de Esgotos (ETE), no adensador por gravidade existente. E, para tanto, foi montada uma ETE Piloto, com a qual foram realizadas as simulações de aplicação de cargas de 2000 mg/L e 4000 mg/L de lodo de ETA A avaliação do desempenho da unidade piloto foi conseguida por meio de monitoramento analítico de parâmetros como: pH, temperatura, oxigênio dissolvido, alcalinidade, DBO, DQO, Fósforo, Nitrogênio, sólidos dissolvidos, totais, fixos e voláteis, turbidez, Índice Volumétrico de Lodo (IVL) e Teor de Lodo (TL). Os resultados mostraram que a carga de 2000 mg/L de lodo de ETA no adensador por gravidade, pode ser realizada sem causar problemas. No entanto, com carga de 4000 mg/L, constatou que as aplicações progressivas de lodo devem ser melhor pesquisadas / In Brazil, very common problem to the biggest part of the communities, where the public water supply is realized using the surface water, and needs to pass by the water treatment plant (WTP). In the treatment process, a residue formation in the form of sludge occurs, which periodically needs to be discarded out the process. Except some WTP, on a nation level all they discarded these residues, in brutal way and without treatment, in watercourses. In this work was realized with the objective to finding an adequate solution to properly allocate the sludge produced in the Water Treatment Plant (WTP) from Presidente Prudente, which is operated by SABESP. This study was based in premise to apply the WTP sludge in the Wastewater Treatment Plant (WWTP), in the thickener by an existing gravity. And however, it was built a WWTP Pilot plant where were realized the simulations of applying dosages of 2000 mg/L and 4000 mg/L of WTP sludge. The evaluation of the performance of the pilot unit was gotten by analytical monitoring of many parameters as: pH, temperature, dissolved oxygen, alkalinity, BOD, COD, phosphorus, nitrogen, dissolved solids, fixed and volatile ones, turbidity, Sludge Volumetric Index (IVL) and sludge concentration (TL). The results showed that the application of 2000 mg/l of WTP sludge in the WWTP gravity thickener can be realized without problems. On the other hand the application of 4000 mg/l showed that progressive applications of sludge have to be better researched
34

Viabilidade financeira da implantação do projeto de construção da estação de tratamento de esgotos - ETE - do Município de Lençóis Paulista - Estado de São Paulo /

Toledo, Julio Cesar Scaramuzzi de. January 2008 (has links)
Orientador: Manoel Henrique Salgado / Banca: Jair Wagner de Souza manfrinato / Banca: Flávio Ferrari Aragon / Resumo: Esta dissertação tem como finalidade, apresentar e comparar dados quantitativos relativos à estação de tratamento de esgotos situada no interior de São Paulo, mais especificamente na cidade de Lençóis Paulista. A proposta do presente trabalho é apresentação de dados financeiros, particularmente retorno e risco do projeto. Dados esses que demonstram também o montante investido, e ainda, as receitas e despesas inerentes ao funcionamento do mesmo. Serão utilizados métodos de análise investimentos tradicionalmente conhecidos como valor presente líquido, taxa interna de retorno e prazo médio de retorno. Para o cálculo da probabilidade de risco do projeto, a distribuição normal será a ferramenta utilizada. É senso comum que um dos maiores fatores de degradação da qualidade da água é justamente a poluição resultante do lançamento dos esgotos sanitários coletados em corpos d'água, o que justifica a necessidade do tratamento desses esgotos, de modo a reduzir a carga poluidora antes de sua disposição final. Segundo dados do Governo Federal apenas 20,2% do esgoto sanitário coletado nos domicílios brasileiros recebem tratamento e só uma pequena parcela tem destinação final sanitariamente adequada no meio (IBGE, 2003). Desta forma, o presente estudo deste problema contemporâneo, demonstrou quantitativamente que a implantação de uma ETE é viável financeiramente, como demonstra os cálculos do valor presente líquido (VPL), taxa interna de retorno (TIR) e o prazo médio de retorno do investimento (payback). Esses métodos de avaliação de investimento foram sensibilizados com uma série que envolve a probabilidade de crescimento populacional, o que possibilitou calcular o risco do projeto, cujo percentual confirma a viabilidade do projeto, em razão do risco calculado ser muito baixo. / Abstract: This dissertation has the purpose to present and compare quantitative data about waste treatment station, placed in Lençóis Paulista city, in the state of Sao Paulo. At first, this work had the intent to present financial and environmental data, however, the project not in operation, it showed only financial data. These data demonstrate the amount of money invested, as also, the revenues and expenses inherent of operation. This work used the traditional investment analysis method, like net present value, interested rate return and payback. To calculate the project risk probability, it was used normal distribution. The waste water collected is fundamental to guarantee the population's life quality. However, one of the major reason to quality's water degradation is the pollution resulted of throwing waste waters in creeks, rivers and others flow waters which justify the need to treat them, reducing the amount of pollution before their final disposal. According to Brazilian's Government statistics, only 20,2% of waste water from brazilian's homes receives proper treatment, and just a small quantity is returned in sanitary way to the environment. (IBGE, 2003). In such a way, this study esposes a contemporary problem, demonstrating quantitatively, that the implementation of ETE is financially viable, like demonstrated calculation of the net present value (NPV), internal interested rate (IRR), and payback. That investments methods evaluation was sensibility through an probability series about population growth, that make possible calculated the project risk, wich result confirm the viability of the project. / Mestre
35

Custo-efetividade e padrões ambientais : implicações para tratamento de esgotos no Brasil

Jardim Junior, Attila Moraes 06 November 2006 (has links)
Dissertação (mestrado)—Universidade de Brasília, Departamento de Economia, 2006. / Submitted by Kathryn Cardim Araujo (kathryn.cardim@gmail.com) on 2009-11-27T15:22:26Z No. of bitstreams: 1 2007_AttilaMoraesJardimJunior.PDF: 840404 bytes, checksum: 088f1f0d882c46f90c2100f20f9a0ebb (MD5) / Approved for entry into archive by Carolina Campos(carolinacamposmaia@gmail.com) on 2009-12-03T20:01:29Z (GMT) No. of bitstreams: 1 2007_AttilaMoraesJardimJunior.PDF: 840404 bytes, checksum: 088f1f0d882c46f90c2100f20f9a0ebb (MD5) / Made available in DSpace on 2009-12-03T20:01:29Z (GMT). No. of bitstreams: 1 2007_AttilaMoraesJardimJunior.PDF: 840404 bytes, checksum: 088f1f0d882c46f90c2100f20f9a0ebb (MD5) Previous issue date: 2006-11-06 / Esta dissertação aborda o estabelecimento de ações governamentais para o equacionamento dos serviços de saneamento objetivando a proteção dos recursos hídricos no Brasil. Há um leque de iniciativas necessárias, boa parte delas requerendo elevados investimentos, que quase nunca têm sido disponibilizados em tempo desejável. O trabalho apresenta as perspectivas dos setores de saneamento e de recursos hídricos no Brasil com a promulgação da Lei Federal 11.445/2007. Com relação à alocação de recursos, a dissertação ressalta que ela tem que ser custo-efetiva e que o estabelecimento de padrões deve ter suporte na teoria econômica ambiental. A revisão literária evidenciou que, quando há escassez, o enfoque de atribuir elevados padrões para tratamento de esgotos sem preocupação com custos e prazos envolvidos não oportuniza os maiores ganhos sociais. A diluição de esgoto nos corpos hídricos deveria assumir um nível ótimo de poluição, permitindo que a meta ambiental proporcionasse a maior satisfação à sociedade. Afinal, de um lado, a sociedade deseja recursos hídricos com qualidade ambiental e, de outro, acaba pagando pelos serviços de saneamento na condição de usuária. A dissertação evidencia a complexidade desse tema e avalia, por meio de modelagem, dois tipos de etapalização na implantação de Estações de Tratamento de Esgoto (ETEs) no Brasil: I) abordagem usual à engenharia; e II) abordagem equi-marginal. A modelagem comparativa de implantação por etapas de 4 ETEs, ao Longo de 20 anos, com desembolso de 6 parcelas de mesmo valor nominal, para 4 cargas poluidoras fixas, evidenciou que o enfoque da análise agregada, com o uso do Princípio da Equi-Marginalidade, apresenta ganhos ambientais acumulados 68% superiores ao caminho usual de implantação por etapas de ETEs. Ao mesmo tempo, o ganhos iniciais do enfoque agregado apresentaram-se comparativamente muito superiores. Já na primeira parcela de recursos liberados, a razão entre os níveis de proteção atingidos foi de 3,75. Embora aparentemente paradoxal, o trabalho mostra que na recuperação de cursos hídricos degradados, na condição atual brasileira, a redução imediata dos padrões pode conduzir à obtenção de maior proteção ambiental. ______________________________________________________________________________________ ABSTRACT / This essay deals with the establishment of government actions to offer sanitation services, aiming the protection of the hydro resources in Brazil. There is a variety of necessary initiatives, a great many of them requiring high cost investments, which are never available in time. The work presents the perspectives of the sanitation and hydro sectors in Brazil with the issuing of the Federal Law 11,445/2007. In relation to the liberation of financial resources, the study points out that they must be cost-effective and that the establishment of standards must be supported by the environmental economic theory. The bibliographic revision evidentiated that, when there is scarcity, attributing high standards for the treatment of sewage without worrying about the costs and deadlines involved does not give conditions to achieve higher social gains. The dilution of sewage into the water bodies should assume an optimal level of pollution, allowing this environmental goal to provide the society with a higher level of satisfaction. Thus, on one hand, the society wants water resources with environmental quality and, on the other hand, it has to pay for the sanitation services, as a user. The work analises the complexity of this theme and evaluates, by means of modeling, two kinds of steps in the implementation of Wastewater Treatment Plants Owned and Operated by Municipalities and Local Sewer Districts (POTWs) in Brazil: I) the usual engineering approach; and II) the equimarginal approach. The comparative modeling of implantation by steps of 4 POTWs, during 20 years with the payment in 6 equal parcels, for 4 fixed polluting cargoes, has made evident that the aggregate analysis wit the use of the Principle of Equi-marginality has presented accumulated environmental gains 68% higher than the usual way of implementation of POTWs by steps. At the same time, the initial gains of the aggregated approach presented comparatively higher levels. Even in the first parcel of authorized resources, the rate between the levels of protection attained has been of 3.75 (equimarginal/engineering approach). Though, supposedly a paradox, the study shows that in the recovery of degraded water streams, in the present Brazilian condition, immediate reduction of the standards may lead to a better environment protection.
36

Avaliação do desempenho da modificação de um sistema de tratamento de esgoto composto por tanque séptico e filtro anaeróbio por um modelo de aeração compartimentada / Performance evaluation of the modification of a sewage treatment system consisting of septic tank and anaerobic filter for a model compartimentalized aeration

França, Josue Tadeu Leite 20 August 2018 (has links)
Orientador: Ronaldo Stefanutti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-20T00:18:11Z (GMT). No. of bitstreams: 1 Franca_JosueTadeuLeite_D.pdf: 5624209 bytes, checksum: 5cf73703ce197d3837470af4dd88e602 (MD5) Previous issue date: 2012 / Resumo: Este trabalho tem como objetivo avaliar o desempenho da modificação concernente a um processo de tratamento "tanque séptico seguido de filtro anaeróbio", no Distrito Bom Retiro, município de Angatuba, região sudoeste do Estado de São Paulo, por um modelo aerado, com aproveitamento integral das unidades existentes após pequenas adequações, visando atender a legislação e com baixo nível de operação. O sistema foi baseado em alguns parâmetros utilizados em lagoas aeradas e parcialmente aeradas. A remoção do lodo para a proposta é anual ou quando o sistema atingir os limites dos parâmetros de controle operacional: DBO efluente ? 60 mg O2 L-1 ou eficiência de remoção dos SST ? 80%. Após um ano de operação da proposta parcialmente concluída (sem tratamento preliminar), apesar de não atingir os limites máximos estabelecidos foram realizadas a quantificação e remoção do lodo gerado. O sistema de desaguamento foi realizado em uma série de "BAGs" verticais de polipropileno reutilizáveis por até 20 vezes, com capacidade para 2m³. Após as adequações, os resultados na segunda etapa do experimento com relação à DBO afluente e efluente, sólidos em suspensão total efluente (SST), residual de oxigênio dissolvido na saída do tanque de polimento, densidade de potência utilizada, custo de energia per capta (kWh ano-1) e custo de implantação per capta foram: DBO afluente e efluente teve como média e desvio padrão 674 ± 137 mg O2 L-1 e 22 ± 5 mg O2 L-1, respectivamente. A média aparada com relação ao residual de oxigênio dissolvido foi de 3,6 ± 1,2 mg L-1, a densidade de potência 42 W m-3, o consumo de energia foi de 56 kWh hab-1 ano-1 e o custo de implantação per capita foi de R$ 140,00. A proposta visa a adequação dos sistemas (tanque séptico + filtro anaeróbio) e implantação em pequenas comunidades, sem sistemas de tratamento de esgotos / Abstract: This work aims to evaluate the performance concerning the modification of the a treatment process "septic tank followed by anaerobic filter", in Bom Retiro district, municipality of Angatuba, and southwest of São Paulo, by aerated model with full use of existing units after minor adjustments, to meet the rules environmental and low level of operation. The system is based on some parameters used in aerated lagoons and partly aerated lagoons. The sludge removal is proposed for the year or when the system reaches the limits of the parameters of operational control: ? 60 mg O2 L-1 BOD effluent and TSS removal efficiency of ? 80%. After a year of operation of the proposed partially completed (without pre-treatment) did not reach the ceilings was conducted to quantify and removal of sludge generated. The dewatering system was conducted in a number of "BAGs" vertical polypropylene reusable for up to 20 times, with a capacity of 2 m³. After the adjustments results in the second stage of the experiment with respect to the influent and effluent BOD, total suspended solids effluent (TSS), residual dissolved oxygen in the tank outlet polishing, power density used, energy cost per capita (kWh year -1) and cost of deployment per capita were: influent and effluent BOD was mean and standard deviation 674 ± 137 mg O2 L-1 and 22 ± 5 mg O2 L-1, respectively. The mean residual trimmed with respect to dissolved oxygen was 3.6 ± 1,2 mg L-1, the power density 42 W m-3, the power consumption was 56 kWh. hab-1 year -1 and implementation cost per capita of R$ 140.00. The proposal aims adequacy of systems (septic tank + anaerobic filter) and deployment in small communities without sewage treatment systems / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil
37

Redução da concentração de fenol presente em águas residuárias utilizando sistema anaeróbio-aeróbio : desempenho e toxicidade residual / Phenol concentration reduction in wastewater using anaerobic-aerobic system : performance and residual toxicity

Carvalho, Luciana Vechi de 21 August 2018 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T10:47:29Z (GMT). No. of bitstreams: 1 Carvalho_LucianaVechide_M.pdf: 1975697 bytes, checksum: c889d2b763a156ae4029456cdc836b88 (MD5) Previous issue date: 2012 / Resumo: A grande utilização de compostos tóxicos e o descarte dos mesmos sem o devido tratamento fizeram com que o ecossistema aquático recebesse grande quantidade de contaminantes, os quais, com o passar do tempo, tendem a estar presentes em maiores concentrações no sedimento dos rios e mananciais que recebem o efluente in natura. O fenol é um dos compostos que tem sido utilizado de forma descontrolada tanto pelas indústrias como também para fins domésticos, aumentando ainda mais a concentração deste nos efluentes sanitários. Desta forma, estudou-se a capacidade de um sistema de tratamento biológico combinado, anaeróbio/aeróbio, em reduzir a concentração de fenol presente em efluentes sanitários. O sistema foi composto por um filtro anaeróbio (FA) seguido por um biofiltro aerado submerso (BAS), monitorado por meio de análises físicas, químicas e ensaios ecotoxicológicos. Para os ensaios ecotoxicológicos foi iniciado o cultivo de dois novos organismos - Chironomus xanthus e Eisenia sp. - viventes no sedimento, para avaliação da resposta de ambos ao fenol, sendo esta a parte dos rios em que há o maior acúmulo de contaminantes Também foi utilizado Daphnia similis. A pesquisa foi realizada em três etapas: Fase de adaptação, com duração de 106 dias, em que o sistema de tratamento recebeu o inóculo de um filtro anaeróbio testado para a remoção de formaldeído; Primeira Fase com a adição de 50 mg L-¹ de fenol, com duração de 207 dias, obtendo eficiências de remoção de fenol próximas a 100% com concentração média de fenol no efluente final de 0,16 mg L-¹ e eficiência de DQO acima de 90% e Segunda fase com duração de 115 dias em que a concentração de fenol aplicada foi gradualmente aumentada até o limite de 150 mg L-¹, determinado pela desestabilização do reator anaeróbio, Foram obtidas eficiências de remoção de fenol de 99,7% e de DQO 95,4% sem reduzir a nitrificação e resultando em um efluente final de acordo com as exigências para o lançamento segundo CONAMA 430/2011. O esgoto bruto contendo fenol foi tóxico para Chironomus xanthus e Daphnia similis com CL(50)/96h 60 mg L-¹ e CE(50)/48h 50 mg L-¹, respectivamente. Para o organismo Eisenia sp., os ensaios indicaram que não ocorreu toxicidade ao fenol. O efluente final tratado pelo sistema biológico combinado não apresentou e não causou toxicidade a nenhum dos organismos testes utilizados, indicando que a sua concepção e proposta de operação produziram um efluente que atende os padrões de lançamento para carga orgânica e fenol, sem prejudicar os índices para o nitrogênio amoniacal / Abstract: The great use of toxic compounds and its dispose without proper treatment, have caused a large concentration of contaminants on the aquatic ecosystem over the time, and the tendency is to be present in higher concentrations in the sediment of rivers and springs that hold the effluent in natura. The phenol, is one of the compounds which has been used in an uncontrolled fashion by both industry and also for domestic purposes, further increasing its concentration in the wastewater. This study shows the ability of a biological treatment system combined anaerobic/aerobic, reducing the concentration of phenol present in wastewater. The system consisted of an Anaerobic Filter (FA) followed by a Submerged Aerated Biofilter (BAS), monitored through physical chemical analysis and ecotoxicological tests. For ecotoxicological tests, the cultivation of two new organisms was started Chironomus xanthus and Eisenia sp. - living in the sediment, to assess the response of both to the phenol, being this the part of the rivers where there is greater accumulation of contaminants, was also used Daphnia similis. The study was performed in three phases: adaptation phase, lasting 106 days, where the Processing System received an inoculum of anaerobic filter, tested for the removal of formaldehyde, First stage with the addition of 50 mg L-¹ phenol, with duration of 207 days, obtaining phenol removal efficiencies close to 100%, with an average of phenol concentration in the final effluent of 0,16 mg L-¹ and efficiency of DQO higher than 90%. Second phase with duration of 115 days , where the phenol concentration applied was gradually increased to the limit of 150 mg L-¹ determined by the destabilization of the anaerobic reactor, were obtained efficiencies in phenol removal of 99.7% and 95.4% of DQO, without reduction the nitrification and resulting in an final effluent according to the requirements for launching as per CONAMA 430/2011. The raw sewage containing phenol was toxic to Chironomus xanthus and Daphnia similis with CL(50)/96h 60 mg L-¹ and CE(50)/48h 50 mg L-¹, respectively. For the organism Eisenia sp., the tests indicated that there was no toxicity to phenol. The final effluent treated by this combined biological system, did not show and did not cause toxicity to any of the test organisms used, thereby indicating that its design and proposed operation, were able to produce an effluent that meets discharge standards for organic load and phenol, while preserving the rates for ammonia nitrogen / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
38

Processo oxidativo avançado na desinfecção de esgoto tratado : helmintos, protozoários e bactérias / Disinfection of treated effluent from wastewater treatment plant by advanced oxidation process : helminths, protozoa and bacteria

Fagnani, Regiane Aparecida Guadagnini, 1984- 11 September 2018 (has links)
Orientadores: José Roberto Guimarães, Regina Maura Bueno Franco / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-09-11T21:23:29Z (GMT). No. of bitstreams: 1 Fagnani_RegianeAparecidaGuadagnini_D.pdf: 2932805 bytes, checksum: ed51cdda9a4191dd5c1b275767a76ecd (MD5) Previous issue date: 2014 / Resumo: Neste estudo foi avaliada a eficiência do processo de tratamento por lodos ativados e, a eficiência de um processo oxidativo avançado (POA), a peroxidação assistida por radiação ultravioleta (H2O2/UV) na desinfecção do efluente da estação de esgoto (ETE) Samambaia da cidade de Campinas/SP. A avaliação da eficiência da ETE e dos processos foi feita com base na remoção de coliformes totais (CT), Escherichia coli (EC), Clostridium perfringens (CP), cistos de Giardia spp. oocistos de Cryptosporidium spp., ovos e larvas de helmintos e, na redução dos valores de turbidez, cor (aparente e verdadeira) e carbono orgânico dissolvido (COD). Para tanto, 13 amostras de afluente e 18 amostras de efluente foram coletadas. O efluente foi desinfetado utilizando-se doses UV de 125 a 20.700 mW s cm-2 e concentração de peróxido de hidrogênio de 30 a 93 mg L-1. Os processos de fotólise e peroxidação foram também avaliados de forma isolada. Todas as amostras de afluente e efluente apresentaram as bactérias avaliadas, cistos de Giardia spp. e, larvas e/ou ovos de helmintos. Na avaliação das características temporais do afluente da ETE, verificou-se que alguns dos parâmetros avaliados, tiveram considerável aumento ou redução com relação ao observado em outros períodos. No período de maior incidência de chuvas (primavera, no ano de 2012) observou-se o menor valor para COD (43% menor do que os obtidos para as outras épocas do ano) e, maior valor para a turbidez (aumento de 57%). Na primavera e no inverno detectou-se também oocistos de Cryptosporidium spp., com maior concentração no inverno. Ovos de helmintos tiveram sua quantificação mínima detectada no outono. A peroxidação aplicada isoladamente não promoveu a inativação de nenhum dos organismos avaliados e, nem reduziu os valores das variáveis físicas e químicas. O POA promoveu a redução de mais de 80% do valor de cor aparente e verdadeira (p < 0,05). Os processos foto-assistidos (radiação UV e H2O2/UV) alcançaram a maior inativação de CT e EC com a dose de radiação de 177 mW s cm-2, sendo de 5 log para a fotólise e, o limite <1 NMP/100mL para o POA e, promoveram a inativação de 2 log de CP, independente da dose de radiação UV aplicada. Quanto aos cistos de Giardia spp., os processos avaliados não promoveram a sua redução. Porém o processo de UV e POA gerou alterações nos cistos (p < 0,05) sendo que o POA alcançou alterações (de fluorescência e/ou forma) em 100% dos cistos observados quando utilizada a dose de radiação UV de 1.775 mW s cm-2. Nenhum dos processos reduziu ou danificou ovos de helmintos, independentemente da condição experimental avaliada / Abstract: This study evaluates the effectiveness of activated sludge and the performance of advanced oxidation process (AOP), the peroxidation assisted by ultraviolet radiation (H2O2/UV), used for effluent disinfection at Samambaia Wastewater Treatment Plant (Samambaia WWTP) in Campinas/SP. The evaluation of the WWTP and of the disinfection processes¿ efficiency was based on the inactivation and/or the number of organisms (total coliforms (TC), Escherichia coli (EC), Clostridium perfringens (CP), Giardia spp. cysts, Cryptosporidium spp. oocysts, helminth eggs and larvae) and turbidity, color (apparent and true) and dissolved organic carbon (DOC) reduced. For this evaluation, 13 samples of affluent and 18 of effluent were collected. The effluent was disinfected using UV doses 125 to 20,700 mW s cm-2 and hydrogen peroxide concentration of 30 to 93 mg L-1. The photolysis and peroxidation processes were separately evaluated. Each affluent and effluent sample revealed the bacteria, Giardia spp. cysts and helminth eggs and/or larvae. In the evaluation of affluent seasonality it has been found that some parameters considerably increased or reduced when different periods were compared. In the period with higher incidence of rain (spring of 2012), it was observed that the DCO value was lower (43% lower when compared to other periods) and, turbidity value was higher (an increase of 57%). In the spring and winter Cryptosporidium spp. oocysts were detected with higher concentration in the winter. Helminth eggs had lower quantification during the autumn. The isolated peroxidation process did not promote the inactivation and/or reduction of any evaluated organism, nor reduced the value of any physical or chemical parameter. The AOP promoted the reduction of 80% or higher of apparent and true color (p < 0.05). The photo-assisted processes (UV radiation and AOP) achieved greater inactivation of TC and EC bacteria with UV dose of 177 mW s cm-2, being 5 log of UV radiation and, <1 MPN/100mL of AOP and, promoted the CP inactivation of 2 log, independent on the UV dose applied. The evaluated processes did not promote the Giardia spp. cysts reduction. However UV and AOP processes caused cysts alteration (p < 0.05), as AOP reached 100% cysts alteration when a 1,775 mW s cm-2 UV dose was applied. Helminth eggs were not reduced or damaged for any studied process, independent on the evaluated experimental condition / Doutorado / Saneamento e Ambiente / Doutora em Engenharia Civil
39

Análise da eficiência e confiabilidade em 56 estações de tratamento de esgotos localizadas na região metropolitana de Fortaleza / Analysis of efficiency and reliability in 56 sewage treatment plants located in the metropolitan area of Fortaleza

Monteiro, Carlo Rannyêr Lopes 27 August 2009 (has links)
MONTEIRO, C. R. L. Análise da eficiência e confiabilidade em 56 estações de tratamento de esgotos localizadas na região metropolitana de Fortaleza. 2009. 77 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2009. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-04-22T17:31:11Z No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-04-29T14:51:15Z (GMT) No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) / Made available in DSpace on 2016-04-29T14:51:15Z (GMT). No. of bitstreams: 1 2009_dis_crlmonteiro.pdf: 768246 bytes, checksum: 4965a4d570ac713ddd564fa4310f71e7 (MD5) Previous issue date: 2009-08-27 / Many Wastewater Treatment Plants (WWTPs) have serious design and / or operational problems that decrease efficiency levels and pollute the environment. Thus, it is important to have efficient and reliable WWTPs to meet the discharge standards. The purpose of this study was to analyze the efficiency and reliability of 56 wastewater treatment plants located in the Metropolitan Region of Fortaleza (MRF). About 13,100 data were evaluated, which were obtained from the Company of Water and Wastewater of Ceará (CAGECE). The data were from January 2005 to April 2009, divided in nine treatment technologies: septic tank (ST), septic tank followed by anaerobic filter (ST + ANF), septic tank followed by anaerobic filter and chlorination (ST + ANF + Cl), facultative pond (FP), facultative pond followed by a maturation pond (FP + MP), anaerobic pond followed by facultative pond and maturation pond (ANP + FP + MP), facultative aerated pond followed by facultative pond and maturation pond (FAP + FP + MP), UASB reactor (UASB) and finally UASB reactor followed by chlorination (UASB + Cl). To calculate the reliability of WWTPs and expected attendance percentage to accomplish effluent standards, a log-normal distribution was used. The average concentrations that the effluent from WWTP must have to meet the discharge standard were calculated for a given reliability level (95%), taking into account the coefficient of reliability (COR). The affluent values of pH, COD, TSS and TTC were compared to those typically found for this type of wastewater. The initial data analysis indicated problems in the monitoring frequency, inconsistencies and outliers, which were removed. The resulting data were used afterwards. The average efficiency values obtained in some technologies are lower than those of comparative literature, indicating operational problems. The highest efficiency values for COD, TSS and TTC were achieved with the technologies of ANP + FP + MP (91,4%), ANP + FP + MP (81.0%) and FAP + FP + MP (99.999%); the lowest efficiencies were obtained with ST + ANF (47.3%), ST (31.6%) and FP (95.36%), respectively. Regarding the coefficient of reliability calculation, the highest values for COD removal were obtained with the technologies of FAP + FP + MP (0.57) and UASB (0.57) and the lowest efficiencies were found with DD + ANF + Cl (0.40). For TSS, the best technologies were FAP + FP + MP (0.43) and FP (0.41) while the lowest CORs were obtained with ANP + FP + MP (0.26). The highest percentage values for accomplishing COD discharge standards were achieved with stabilization ponds, all above 98%, specially the technology FAP + FP + MP (99.9%). For TSS the highest percentages were also achieved with stabilization ponds, highlighting the technology of ANP + FP + MP (91%). The technologies of FAP + FP + MP and ANP + FP + MP provided the best efficiency values for COD, TSS and TTC, as well as the highest values of COR and percentages to accomplish discharge standards. / Diversas estações de tratamento de esgoto possuem sérios problemas de projeto e / ou operacionais os quais prejudicam o seu processo de tratamento e geram riscos de poluição dos recursos hídricos receptores. Assim, há a necessidade de tratamentos de esgotos cada vez mais eficientes e confiáveis para obedecerem aos padrões de descarte definidos em legislações ambientais cada vez mais restritivas. O objetivo do presente estudo foi analisar a eficiência e a confiabilidade de 56 estações de tratamento de esgotos situadas na Região Metropolitana de Fortaleza (RMF). Para tanto, foram avaliados cerca de 13.100 dados obtidos do monitoramento dos esgotos afluente e efluente às ETEs, durante o período de janeiro de 2005 a abril de 2009, as quais foram divididas em nove modalidades de tratamento, quais sejam: decanto-digestor (DD), decanto-digestor seguido de filtro anaeróbio (DD+FAN), decanto-digestor seguido de filtro anaeróbio e cloração (DD+FAN+Cl), lagoa facultativa (LF), lagoa facultativa seguida de lagoa de maturação (LF+LM), lagoa anaeróbia seguida por lagoa facultativa e lagoa de maturação (LAN+LF+LM), lagoa aerada facultativa seguida por lagoa facultativa e lagoa de maturação (LAF+LF+LM), reator UASB (UASB) e, por fim, reator UASB seguido de cloração (UASB+Cl). Para o cálculo da confiabilidade das ETEs e do percentual esperado de atendimento aos padrões de lançamento foi utilizada uma metodologia baseada em um modelo de distribuição log-normal dos dados, a qual determina concentrações médias que o efluente da ETE deve ter para obedecer aos padrões ambientais de lançamento para um determinado nível de confiabilidade (95%), levando em consideração o coeficiente de confiabilidade (CDC). Os valores afluentes de pH, DQO, SST e CTT foram comparados aos que são tipicamente encontrados para esse tipo de esgoto. Na avaliação inicial dos dados observou-se não haver freqüência de monitoramento, bem como, constatou-se a presença de inconsistências e outliers, os quais foram removidos. Os dados resultantes foram utilizados na seqüência da análise. Várias tecnologias de tratamento tiveram valores de eficiência inferiores ao que é registrado na literatura, indicando falhas operacionais no monitoramento das ETEs. Os maiores percentuais médios de remoção de DQO, SST e CTT foram alcançados pelas modalidades LAN+LF+LM (91,4%), LAN+LF+LM (81,0%) e LAF+LF+LM (99,999%) e os menores foram DD+FAN (47,3%), DD (31,6%) e LF (95,36%), respectivamente. Estes resultados mostram-se condizentes com os encontrados na literatura para todas as tecnologias de tratamento, exceto para remoção de SST por DD (31,6%) e DD+FAN (37,3%). No que se refere ao cálculo do coeficiente de confiabilidade foram obtidos para DQO os maiores valores pelas modalidades LAF+LF+LM (0,57) e UASB (0,57) e o menor valor para DD+FAN+Cl (0,40). Já para SST as tecnologias que se destacaram foram LAF+LF+LM (0,43) e LF (0,41) enquanto que o menor CDCs foi obtido por LAN+LF+LM (0,26). Os maiores percentuais esperados de atendimento às metas de descarte para DQO foram alcançados pelos tratamentos compostos por lagoas de estabilização, todos acima de 98%, destacando-se a tecnologia LAF+LF+LM (99,9%). Para SST os maiores percentuais obtidos também foram para as lagoas de estabilização, ressaltando a tecnologia LAN+LF+LM (91%). A tecnologia de tratamento DD foi a de menor percentual para DQO (1,2%) e para SST (2,0%). As modalidades de tratamento de esgotos domésticos LAF+LF+LM e LAN+LF+LM apresentaram um melhor desempenho considerando as eficiências médias de remoção de DQO, SST e CTT, como também maiores valores de CDC e percentuais esperados de atendimento às metas estabelecidas pela legislação.
40

Avaliação da aplicação de lodo de ETA no adensador de lodo de uma ETE de lodos ativados /

Peixoto, Gilmar José. January 2008 (has links)
Orientador: Tsunao Matsumoto / Banca: Dib Gebara / Banca: Rodrigo Braga Moruzzi / Resumo: No Brasil, existe um problema comum à maioria das comunidades onde o abastecimento público de água é realizado com água superficial e há a necessidade de tratamento. No processo de tratamento ocorre a formação de resíduos na forma de lodo, o qual periodicamente necessita ser descartado do processo. Exceção feita a algumas Estações de Tratamento de Água (ETA), em nível nacional, todas despejam esses resíduos, de forma bruta, sem nenhum tratamento, em corpos de água. O presente trabalho foi realizado com o objetivo de encontrar solução adequada para destinar, de forma correta, o lodo produzido pela ETA da cidade de Presidente Prudente, operada pela Companhia de Saneamento Básico do Estado de São Paulo (SABESP). O estudo baseou-se na premissa em aplicar o lodo da ETA na Estação de Tratamento de Esgotos (ETE), no adensador por gravidade existente. E, para tanto, foi montada uma ETE Piloto, com a qual foram realizadas as simulações de aplicação de cargas de 2000 mg/L e 4000 mg/L de lodo de ETA A avaliação do desempenho da unidade piloto foi conseguida por meio de monitoramento analítico de parâmetros como: pH, temperatura, oxigênio dissolvido, alcalinidade, DBO, DQO, Fósforo, Nitrogênio, sólidos dissolvidos, totais, fixos e voláteis, turbidez, Índice Volumétrico de Lodo (IVL) e Teor de Lodo (TL). Os resultados mostraram que a carga de 2000 mg/L de lodo de ETA no adensador por gravidade, pode ser realizada sem causar problemas. No entanto, com carga de 4000 mg/L, constatou que as aplicações progressivas de lodo devem ser melhor pesquisadas / Abstract: In Brazil, very common problem to the biggest part of the communities, where the public water supply is realized using the surface water, and needs to pass by the water treatment plant (WTP). In the treatment process, a residue formation in the form of sludge occurs, which periodically needs to be discarded out the process. Except some WTP, on a nation level all they discarded these residues, in brutal way and without treatment, in watercourses. In this work was realized with the objective to finding an adequate solution to properly allocate the sludge produced in the Water Treatment Plant (WTP) from Presidente Prudente, which is operated by SABESP. This study was based in premise to apply the WTP sludge in the Wastewater Treatment Plant (WWTP), in the thickener by an existing gravity. And however, it was built a WWTP Pilot plant where were realized the simulations of applying dosages of 2000 mg/L and 4000 mg/L of WTP sludge. The evaluation of the performance of the pilot unit was gotten by analytical monitoring of many parameters as: pH, temperature, dissolved oxygen, alkalinity, BOD, COD, phosphorus, nitrogen, dissolved solids, fixed and volatile ones, turbidity, Sludge Volumetric Index (IVL) and sludge concentration (TL). The results showed that the application of 2000 mg/l of WTP sludge in the WWTP gravity thickener can be realized without problems. On the other hand the application of 4000 mg/l showed that progressive applications of sludge have to be better researched / Mestre

Page generated in 0.091 seconds