• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 414
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 426
  • 232
  • 79
  • 78
  • 68
  • 60
  • 58
  • 58
  • 45
  • 41
  • 41
  • 41
  • 40
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Avaliação clínica da sensibilidade e efetividade do clareamento em consultório de dentes polpados, com e sem o emprego de fonte de luz: controle de 12 meses / Clinical evaluation of sensitivity and effectiveness of in-office whitening in sounds teeth, with and without the use of light source: 12 months follow-up

Rosa, Enio Ratton 14 May 2012 (has links)
Este estudo in vivo analisou comparativamente duas técnicas de clareamento de dentes polpados, quanto ao grau de sensibilidade, mudança de cor e estabilidade do tratamento num período de doze meses. Dez pacientes foram selecionados de acordo com os critérios de inclusão e exclusão, e submetidos ao clareamento em consultório, sendo que o mesmo paciente recebeu os dois protocolos de clareamento. Grupo A (GA): três aplicações de 15 (totalizando 45) do gel de peróxido de hidrogênio (PH) 35% (Lase Peroxide Sensy, DMC Equipamentos Ltda.), nos hemi-arcos inferior e superior esquerdo. Grupo B (GB): três aplicações do gel PH 35% ativado com luz híbrida de LED/laser de diodo (Whitening Lase II DMC Equipamentos Ltda.) por 2, com intervalo de 30 (730), totalizando 2230, nos hemi-arcos inferior e superior direito. A avaliação da cor foi realizada com o espectrofotômetro Vita EasyShade (VITA), sendo a diferença mensurada através do sistema CIE-Lab antes do clareamento, após 24 horas, 1 semana, 6 e 12 meses. A sensibilidade dentária foi avaliada por meio do questionário VAS antes, imediatamente após o clareamento, após 24 horas e 1 semana. Para as variáveis luminosidade (?L) e alteração de cor (?E), ANOVA a dois critérios (período e luz) revelou haver diferenças estatisticamente significantes intra e intergrupos em função dos períodos avaliados (p<0,001). O teste de Tukey (p<0,001) para comparações individuais apontou diferenças significantes intergrupos para os dentes superiores nos períodos de 1 mês, 6 meses e 1 ano com os demais tempos avaliados. Para os dentes inferiores não houve diferenças estatísticas intra e intergrupos (p=0.0821). O GB ativado com luz apresentou, imediatamente após o clareamento, o menor grau de sensibilidade dentária com diferença estatística (p=0,043) em comparação ao GA (sem luz). Os dois protocolos de clareamento com e sem luz avaliados durante 12 meses foram semelhantes quanto a efetividade do clareamento dental. Por outro lado, a utilização da fonte de luz híbrida diminuiu o tempo de tratamento em 50% e proporcionou menor grau de sensibilidade pós-operatória. / This study examined in vivo comparison of two techniques for whitening pulp teeth, the degree of sensitivity, color change and stability of treatment over a period of twelve months. Ten patients were selected according to the criteria for inclusion and exclusion, and subjected to in-office bleaching, and the same patient received both protocols whitening. Group A (GA): three applications of 15\' (total 45\') of hydrogen peroxide gel (PH) 35% (Sensy Lase Peroxide, DMC Equipment Ltd.), Hemi-arches in the lower and upper left. Group B (GB): three applications of the gel 35% PH with light activated hybrid LED / laser diode (Whitening Lase II DMC Equipments Ltda.) By 2 \', with an interval of 30\' (7\'30\"), totaling 22\'30\", hemi-arches in the lower and upper right. The evaluation was performed color with the spectrophotometer Vita Easyshade (VITA), and the difference measured with the CIE-Lab system before the treatment, after 24 hours, 1 week, 6 and 12 months. The tooth sensitivity was assessed using the VAS questionnaire before and immediately after bleaching, after 24 hours and 1 week. For the variable brightness (?L) and color change (?E), two-way ANOVA (time and light) revealed statistically significant differences within and between groups on the basis of the evaluation period (p<0.001). The Tukey test (p<0.001) for individual comparisons showed significant differences between groups for the upper teeth at 1 month, 6 months and 1 year with the other times evaluated. For the lower teeth no statistical differences within and between groups (p=0.0821). The GB had activated with light, immediately after bleaching, the lowest degree of tooth sensitivity with statistical difference (p=0.043) compared to GA (no light). The two protocols with and without light bleaching evaluated during 12 months were similar in effectiveness of tooth whitening. Moreover, the use of the light source hybrid decreases the time of treatment provided by 50% and less sensitivity postoperative.
102

Análise da cicatrização de lesões cutâneas através da espectrofotometria: estudo experimental em ratos diabéticos.

Carvalho, Paulo de Tarso Camillo de 06 February 2002 (has links)
O trabalho tem por objetivo desenvolver um protocolo experimental de avaliação da cicatrização de lesões cutâneas em ratos diabéticos (aloxânicos) através da análise do espectro de cor das fibras colágenas e de macrófagos. Considerando que em indivíduos normais, os mecanismos que regulam a cicatrização são bem conhecidos, determinou-se neste estudo verificar os mecanismos que regulam a cicatrização de animais diabéticos. Utilizamos inicialmente 60 ratos Wistar, machos. O diabetes foi induzido por injeção intravenosa (veia dorsal do pênis de Aloxana (2, 4, 5, 6 - Tetraoxypyrimidina; 5 - 6 Dioxyuracila) SIGMA, 0,1ml de solução a cada 100 g. de peso corporal. Para se chegar ao número de 12 ratos diabéticos, foram utilizados 48 ratos, destes 39,58% não desenvolveram a hiperglicemia nos néveis fixados (acima de 250mg/l ), 6,25% morreram por hipoglicemia nas primeiras 24 horas; nas 48 horas seguintes 20,83% % morreram por hiperglicemia, 4,17% morreram durante procedimento anestésico e 4,17% morreram ao longo do experimento. Foi realizada uma lesão no dorso dos animais que foram divididos em 2 grupos com 12 animais cada e receberam a denominação de Grupo 1 Diabético Grupo 2 Não Diabético. As 24 amostras dos tecidos colhidas no 3º, 7º e 14º após a lesão, foram incluídas em parafina e cortadas transversalmente e passaram por dois processos distintos, ou seja, 24 amostras por coloração com Tricrômico de Masson e 24 amostras pela técnica imunohistoquímica - anticorpo monoclonal HAM 56. Utilizou-se o software IMAGELAB para a análise morfométrica do percentual de fibras colágenas por densidade de cor e número de macrófagos evidenciados pela imunohistoquímica. Os dados obtidos em relação ao percentual de fibras colágenas e macrófagos foram tratados estatisticamente por testes paramêtricos de análise de variância, segundo dois critérios, e confirmados pelo Teste "Tukey" onde se fixou em 5% o nível de rejeição da hipótese de nulidade. Fixando-se: para ambos p< 0,5. Concluímos que o protocolo experimental para avaliação da cicatrização de lesões em ratos diabéticos se mostrou eficaz, demonstrando que a cicatrização no grupo de animais diabéticos apresentou-se retardada durante todas as etapas do processo de reparo e que a porcentagem de fibras colágenas e macrófagos pode ser facilmente analisada pelo espectro de cor. / This study aims to develop an experimental evaluation protocol of the healing of skin wounds in diabetic rats (aloxanic) through the analysis of color spectrum of collagenous fibres and macrophage. Considering that the mechanisms regulating scarring in normal individuals are well-known it was determined to verify the mechanisms regulating the scarring in diabetic animals. 60 Wistar male rats were used. Diabetes was induced by means of intravenous injection (dorsal penis vein of Aloxana (2, 4, 5, 6 - Tetraoxypyrimidine; 5 - 6 Dioxyuracila) SIGMA, 0,1 ml of solution per 100g of body weight. In order to reach 12 diabetic rats, 48 rats were used. 39.58% of them did not develop hypoglycemia in the established levels (above 250mg/l), 6.25% died from hypoglycemia within 24 hours; in the following 48 hours, 20.83% died from hypoglicemia, 4,17% died during the anesthetic procedures and 4,17% died along the experiment. In order to follow the study a lesion was performed on the back of the animals which were divided into two groups with 12 animals each and received the following denomination: Group I Diabetic and Group II Non-Diabetic. The 24 tissue samples collected in the 3rd , 7th and 14th days after the lesion were included in paraffine and transversally cut and suffered two different processes, that means, 24 samples received coloration with Masson Tricomic and 24 samples suffered the imunohistochemical technic - HAM 56 monoclonic antibody. The software IMAGELAB was used in the morphometric analysis of the percentage of collagen by density of colour and number of macrophage highlighted by immunehistochemistry The obtained data concerning the percentage of collagenous fibres and the number of macrophage were statistically treated by ANOVA following two criteria and confirmed by Tukey Test where the rejection level of nullity possibility was established to be 5% (alpha<=0,05). It was obtained p< 0,5 for both. We came to the conclusion that the experimental protocol for the evaluation of healing of wounds in diabetic rats has proved efficient, showing that the healing in the group of diabetic animals is slowed down during all the stages of the repairing process; the percentage of collagenous fibres and macrophage can be easily analysed by the colour spectrum.
103

Estudos dos efeitos do ultra-som na veiculação de fitoterápicos através da análise da degradação da Arnica montana

Cerutti, Débora Giseli Urnau 27 March 2009 (has links)
Submitted by Ana Paula Lisboa Monteiro (monteiro@univates.br) on 2009-05-11T14:17:16Z No. of bitstreams: 1 DeboraCerutti.pdf: 2617243 bytes, checksum: 8bab260c6b58c94503ef3461ac0f2b08 (MD5) / Made available in DSpace on 2009-05-11T14:17:16Z (GMT). No. of bitstreams: 1 DeboraCerutti.pdf: 2617243 bytes, checksum: 8bab260c6b58c94503ef3461ac0f2b08 (MD5) / A Arnica montana é um fitoterápico comumente utilizado com fins medicinais devido ao efeito anti-inflamatório que possui. Da mesma forma, o equipamento de Ultra-som Terapêutico (UST) é utilizado na Fisioterapia para controlar sinais inflamatórios como dor e edema, além de, através da fonoforese, veicular substâncias através da pele devido a sua capacidade de alterar a permeabilidade da membrana celular, proporcionando desta forma, aumento da absorção de substâncias de uso terapêutico. Considerando os efeitos da Arnica montana, da técnica de fonoforese através do ultra-som e o desenvolvimento tecnológico de medicamentos de origem vegetal, o objetivo geral da presente pesquisa é investigar o potencial de degradação da Arnica montana quando submetida ao uso de UST, através de fonoforese, por meio de técnicas de espectrofotometria, voltametria cíclica e amperometria. Para esta análise, foram utilizadas amostras de extrato glicólico de Arnica montana na diluição de 100 mL/L. O ultra-som foi aplicado no modo contínuo e pulsado (a 100 Hz com ciclos de duração de pulso de 20%) na intensidade de 1,0 W/cm2, nos tempos de 0, 5, 15, e 25 minutos. As técnicas de espectrofotometria, voltametria cíclica e amperometria foram realizadas antes e após a exposição das amostras ao Ultra-Som, construíndo-se curvas analíticas comparadas às curvas obtidas na ausência de radiação. Os resultados demonstram possibilidade de detecção da degradação da Arnica montana através das técnicas analíticas utilizadas. Sendo assim, concluiu-se que a ação física e química do US, tanto contínuo quanto pulsado, promove alteração eletroquímica do substrato estudado (Arnica montana) envolvendo o solvente (água) e também o extrato. A degradação do extrato de Arnica (formação de subprodutos) permite sugerir o aumento da mobilidade molecular, fator este positivo no que se refere ao uso do US, através da técnica de fonoforese.
104

Análise químico-farmacêutica e estudos de estabilidade e de dissolução de comprimidos de orbifloxacino /

Cazedey, Edith Cristina Laignier. January 2012 (has links)
Orientador: Hérida Regina Nunes Salgado / Banca: Elfrides Eva Scherman Schapoval / Banca: Magali Benjamim de Araújo / Banca: Álvaro José dos Santos Neto / Banca: Marlus Chorilli / Resumo: O orbifloxacino é uma fluorquinolona antimicrobiana de terceira geração aprovada para o uso veterinário em vários países. Este antimicrobiano possui excelente farmacocinética, com biodisponibilidade oral quase completa e é utilizado no tratamento de infecções causadas por bactérias Gram-negativas, incluindo Enterobacteriaceae e espécies Pseudomonas-resistentes e também por micro-organismos Gram-positivos e Mycoplasma sp. Muitos estudos têm demonstrado que o orbifloxacino é eficaz contra diversos patógenos apresentando baixa concentração inibitória mínima. A importância de se desenvolver e validar métodos analíticos para este fármaco é justificada por seu potencial terapêutico e grande emprego em terapias anti-microbianas, assim como pelo conhecimento de que a baixa qualidade dos produtos anti-infecciosos está relacionada ao desenvolvimento de cepas resistentes, como consequência da administração de doses subterapêuticas. Neste trabalho foram desenvolvidos ensaios para a análise qualitativa de orbifloxacino utilizando a espectrofotometria nas regiões do UV/VIS/IV, cromatografia líquida de alta eficiência, análise térmica, cromatografia em camada delgada e outros métodos gerais para caracterização da substância química de referência (SQR) e comprimidos de orbifloxacino. Técnicas analíticas, espectrofotométrica no UV, indicativa de estabilidade por cromatografia líquida de alta eficiência e microbiológicas - difusão em ágar e turbidimétrica foram utilizadas para o desenvolvimento e validação dos métodos para determinação quantitativa deste fármaco na forma farmacêutica... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Orbifloxacin, a new synthetic third-generation fluoroquinolone antimicrobial drug, was developed exclusively for use in veterinary medicine. This antimicrobial agent has an excellent pharmacokinetics with oral bioavailability almost complete and it is used in treatment of infections caused by Gram-negative bacteria, including Enterobacteriaceae and Pseudomonas-resistant species and also by Gram-positive microorganisms and Mycoplasma sp. Many studies have shown that orbifloxacin is effective against many pathogens and has low minimum inhibitory concentration. Analytical methods for quantitative determination of orbifloxacin are important due to its therapeutic potential and wide use in antimicrobial therapy. Moreover, it is known that the poor quality of antibiotic product is direct related to development of resistant strains, as consequence of sub therapeutic doses administration. Thus, it is important to develop efficient analytical methods for quality control commercialized products. In this work were developed methods for qualitative analysis of orbifloxacin using UV/VIS/IR spectrophotometry, high performance liquid chromatography, thermal analysis, thin-layer chromatography and other general methods for characterization of API and tablets of orbifloxacin. Analytical methods such as UV spectrophotometry, stability-indicating high performance liquid chromatography and microbiological - agar diffusion and turbidimetry were developed and validated for quantitation of this drug in tablets. All... (Complete abstract click electronic access below) / Doutor
105

Avaliação in vitro das superfícies vestibulares desmineralizadas e restauradas com resina infiltrante / In vitro evaluation of buccal surfaces demineralized and restored with resin infiltration

Fernando Seishim Hanashiro 04 December 2012 (has links)
Nos dias atuais, os pacientes tem uma grande preocupação com a estética dos dentes. Alterações de posicionamento é um exemplo de problema que o paciente tem interesse em resolver com o tratamento ortodôntico. No entanto, o próprio tratamento ortodôntico tem como característica o uso de acessórios que podem facilitar o acúmulo de resíduos alimentares e dificultar a higienização. Facilitando o desenvolvimento de lesões cariosas. Este estudo in vitro se propôs a avaliar o efeito do mascaramento de tecido dental desmineralizado quando restaurado com a resina infiltrante. Vinte superfícies vestibulares obtidas através de incisivos bovinos tiveram suas superfícies planificadas. Cada espécime foi individualizado de modo que toda leitura para recolhimento de dados fosse feita na mesma superfície. Os espécimes foram submetidos a análise por espectrofotômetro, para obtenção de coordenadas de cor, e a análise da perda mineral, através de quantificação de fluorescência induzida por luz (QLF), sendo que essas análises foram feitas nos tempos: inicial, pós ciclagem de pH, após restauração com a resina infiltrante e após hidratação da resina infiltrante. A análise inicial foi feita de modo a ser obtido o valores iniciais de cor e de conteúdo mineral dos espécimes. Após a leitura inicial, os espécimes foram submetidos a ciclagem de pH durante 16 dias, permanecendo diariamente em soluções desmineralizadora e remineralizadora por 6horas e 18 horas respectivamente. Após o desafio ácido, os espécimes foram avaliados, sendo este o tempo denominado Inicial. Em seguida os espécimes foram restaurados utilizando a resina infiltrante seguidos de nova avaliação, sendo este tempo denominado Icon. Os espécimes permaneceram em água destilada para hidratação da resina e submetidos a nova avaliação, sendo este tempo denominado Hidratado. Pode-se concluir que a variação total de cor (E), é perceptível ao observador comum, quando comparado à cor inicial com a cor após a restauração. Enquanto que a análise feita pelo QLF, a perda mineral não foi detectada após a hidratação da resina infiltrante. / In the present days, patients have a major concern with the aesthetics of teeth. Changes positioning is an example of a problem that the patient is interested in resolve with orthodontic treatment. However, the actual orthodontic treatment is characterized by the use of accessories that can facilitate the accumulation of food residues and hinders hygiene. This facilitates the development of caries lesions. This in vitro study aimed to evaluate the effect of masking demineralized dental tissue when restored with the infiltrant resin. Twenty buccal surfaces obtained from bovine incisors had planned their surfaces. Each specimen was individualized so that the entire data for analysis was done on the same surface. The specimens were analyzed by spectrophotometer for obtaining color coordinates, and the analysis of mineral loss through quantification of light-induced fluorescence (QLF), and these analyzes were made at times: initial pH cycling post, after restoration with resin infiltrating and. The specimens were analyzed by spectrophotometer for obtaining color coordinates, and the analysis of mineral loss through quantification of light-induced fluorescence (QLF), and these analyzes were made at times: initial pH cycling post, after restoration with resin infiltrating and infiltrating resin after hydration. The initial analysis was made in order to obtain the initial values of color and mineral content of the specimens.. After the initial reading, the specimens were subjected to pH cycling for 16 days, daily remaining in demineralizing and remineralizing solution for 6 hours and 18 hours respectively. After the acid challenge, the specimens were evaluated, this time called Inicial. Then the specimens were restored using resin infiltration followed new analysis, this time being named Icon. The specimens remained in distilled water for hydratation of the resin and subjected to new analysis, this time being called Hidratado. It can be concluded, that the total variation of color (E) is perceptible to the casual observer, when compared to the initial color with the color after restoration. While the analysis by QLF, the mineral loss was not detected after hydratation of resin infiltration.
106

Desenvolvimento de procedimento analítico para determinação de iodato em sal de mesa utilizando sistema com multicomutação e detecção espectrofotométrica / Development of analytical procedure for determination of iodate in table salt using a multicommuted system and spectrophotometric detection

Amanda Ribeiro Martins da Silva 18 April 2016 (has links)
A iodação do sal de mesa é considerada o caminho mais eficiente para controlar os Distúrbios por Deficiência de Iodo. Em países tropicais, o elemento pode ser adicionado na forma de KIO3. Para garantir que os níveis ideais do ânion estejam disponíveis ao consumidor, o controle de qualidade do sal consiste numa estratégia fundamental. Sistemas em fluxo com multicomutação representam uma alternativa versátil para o desenvolvimento de procedimentos simples, rápidos e limpos, minimizando o consumo de reagentes e a geração de resíduos. Nesse contexto, um procedimento analítico utilizando sistema com multicomutação e detecção espectrofotométrica foi desenvolvido para a determinação de iodato em sal de mesa. A reação empregada foi baseada na formação de um composto roxo (540 nm) entre iodato (IO3-) e p-aminofenol (PAP) em meio ácido. O tempo de residência da zona de amostra no percurso analítico foi explorado a fim de favorecer a reação lenta e a frequência de amostragem para a melhoria do desempenho analítico. Foram selecionados 2 pulsos para inserção de amostra, 3 pulsos para reagente (PAP 0,25% (m/v) em HCl 0,025 mol L-1), 7 ciclos de amostragem, 200 pulsos de carregador (água), bolha de ar de 1 s (40 µL), reator de 70 cm (3 mm d.i.) e parada de fluxo de 480 s. Resposta linear foi observada entre 2,28x10-5 e 3,65x10-4 mol L-1, descrita pela equação A = 0,2443 + 2030 C, r = 0,997. Limite de detecção (99,7% de confiança), coeficiente de variação (n = 20) e frequência de amostragem foram estimados em 8,2x10-6 mol L-1, 0,42% e 70 determinações por hora, respectivamente. Houve consumo de 1,05 mg de PAP e geração de 0,70 mL de resíduos por determinação. As principais espécies concomitantes presentes na amostra não interferiram na determinação de iodato em concentrações até 8 vezes maiores que as usualmente encontradas. Estudos de adição e recuperação de iodato foram realizados pelo procedimento proposto, obtendo porcentagens de recuperação entre 88 e 104%. O procedimento analítico desenvolvido apresenta sensibilidade adequada para a determinação de iodato em amostra de sal de mesa e elevada frequência de amostragem quando comparado com procedimentos descritos na literatura / Table salt iodization is considered the most efficient way to control iodine-deficiency disorders. In tropical countries, the element can be added as KIO3. To ensure that ideal amounts of this anion are available to consumers, the quality control of iodized salt is fundamental strategy. Multicommuted flow systems represent a versatile alternative to the development of simple, fast and clean procedure, minimizing reagent consumption and waste generation. In this context, an analytical procedure using a multicommuted system and spectrophotometric detection was developed for determination of iodate in table salts. The chemical reaction was based on the formation of purple compound (540 nm) between iodate (IO3-) and p-aminophenol (PAP) in acidic medium. The sample residence time in the analytical path was explored in order to further the slow chemical reaction and the sampling rate for the improvement of the system analytical performance. Optimized conditions were 2 sample pulses, 3 reagent pulses (PAP 0.25% (w/v) in HCl 0.025 mol L-1) in 7 sampling cycles, 200 carrier pulses (water), 1 s air bubble (40 µL), a 70-cm long reactor coil (3 mm i.d.) and the flow was stopped for 480 s. A linear response was observed between 2.28x10-5 and 3.65x10-4 mol L-1 iodate, described by the equation A = 0.2443 + 2030 C, r = 0.997. Detection limit (99.7% confidence level), coefficient of variation (n = 20) and sampling rate were 8.2x10-6 mol L-1, 0.42% and 70 determination per hour, respectively. Only 1.05 mg of PAP was consumed and 0.70 mL of waste was generated per determination. Usual concomitant species found in table salts did not cause significant interference in concentrations up to 8-fold higher than those expected. Recoveries between 88 and 104% were obtained for iodate spiked samples. The developed analytical procedure presented adequate sensitivity for the determination of iodate in table salts sample and higher sampling rate compared to literature procedures
107

Avaliação da quantidade de formaldeído liberado por alguns cimentos endodônticos / Evaluation of the quantity of formaldehyde released by some endodontic sealers

Jose Estevam Vieira Ozorio 27 April 2012 (has links)
Analisou-se, por meio de espectrofotometria, a liberação de formaldeído de cimentos endodônticos à base de óxido de zinco e eugenol, resinas epóxica e polimetacrilato, hidróxido de cálcio e biocerâmico, estudados em diferentes oportunidades: durante a espatulação; decorrido três vezes o tempo de endurecimento e, por fim, na extração de sua massa endurecida. As amostras foram adquiridas pela coleta do volume da água utilizada em cada período e, determinada a curva de calibração da liberação do formaldeído e análise controle com água, foram submetidas à análise colorimétrica com adição dos reagentes: 5,0 mL de solução tampão, 0,5 mL de solução de parafenilenodiamina e 2,5 mL de peróxido de hidrogênio em balões volumétricos de 50,0 mL mantendo-os em repouso por 20 minutos. Após, foi realizada leitura em espectrofotômetro duplo feixe nos comprimentos de onda 326, 334 e 462 nm. Detectou-se formaldeído em todos os cimentos à base de resina epóxica, no EndoREZ® e no Endomèthasone N, quantificado apenas no Sealer 26 (7.40 mg.L-1) e Endomèthasone N (9.13 mg.L-1) durante a espatulação; no AH Plus® (4.44 mg.L-1) e no Endomèthasone N (18.14 mg.L-1) durante o endurecimento, e somente no Endomèthasone N depois de endurecido (9.43 mg.L- 1). Concluiu-se que, durante a espatulação, todos os cimentos de resina epóxica liberaram formaldeído, com quantificação apenas para o Sealer 26, o Endomèthasone N apresentou a maior quantidade, e o Endorez liberou a substância em quantidade insuficiente para quantificação. Após a espatulação, todos os de resina epóxica liberaram formaldeído, com quantificação no AH Plus e o Endomèthasone N apresentou a maior quantidade da substância, que também foi encontrada no Endorez, sem quantificação. Endurecidos, todos os cimentos de resina epóxica e o Endorez liberaram formaldeído em quantidade insuficiente para quantificação, e o cimento Endomèthasone N liberou a maior quantidade dessa substância. / This study evaluated, by means of spectrophotometry, the release of formaldehyde in zinc oxide, epoxy resins and polymethylmethacrylate, calcium hydroxide and bioceramic based endodontic sealers in different situations: during mixing; after 3 time the setting time and, at extraction of its hardened mass. The samples were acquired by means of collection of the volume of water used in each period and - after determining the calibration curve of formaldehyde release and analyzing the control with water - were submitted to colorimetric analysis with the addition of the following reagents: 5.0mL of buffered solution, 0.5mL of paraphenylenediamine and 2.5mL of hydrogen peroxide to a 50.0mL volumetric flask, which was kept at rest for 20 minutes. Double-beam spectrophotometer readings were performed at 326, 334 and 462nm wavelengths. Formaldehyde was detected in all epoxy resin based sealers, in EndoREZ and in Endomèthasone N, quantified only in Sealer 26 (7.40 mg.L-1) and Endomèthasone N (9.13 mg.L-1) during mixing, and in AH Plus (4.44 mg.L-1) and Endomèthasone N (18.14 mg.L-1) during the setting time, and only in Endomèthasone N after setting (9.43 mg.L-1). It can be concluded that during mixing all epoxy resin based sealers released formaldehyde, with quantification being possible only for Sealer 26, Endomèthasone N showed higher quantities, and Endorez released the substance in insufficient quantity for detection. After mixing, all epoxy resin based sealers released formaldehyde, whereas quantification was possible for AH Plus and Endomèthasone N presented the highest quantity of the substance, that was also found in Endorez, but could not be quantified. When set, all epoxy resin sealers and Endorez released formaldehyde in insufficient quantity for quantification, and Endomèthasone N released the greater amount of this substance.
108

Determinação espectrofotométrica de selênio em rações para animais empregando análise por injeção em fluxo / Spectrophotometric determination of selenium in ration for domestic animals employing flow injection analysis

Frizzarin, Rejane Mara 20 October 2008 (has links)
Na presente dissertação foi desenvolvido um procedimento automático para a determinação de selênio em rações para animais doméstico digeridas em meio ácido. O método automatizado foi baseado no efeito catalítico do selênio(IV) na reação de sulfato de ferro amoniacal com EDTA em meio contendo NaNO3. O módulo de análise foi baseado no processo de multicomutação em fluxo. Tendo em vista que reação tem cinética lenta, o módulo de análise foi projetado com seis bobinas de reação acopladas em paralelo para permitir tempo de residência da zona de amostra em torno de cinco minutos, sem comprometer a freqüência de amostragem. Após a definição das variáveis de controle, amostras de rações para animais digeridas em meio de ácido nítrico/perclórico foram processadas. Os resultados referentes ao testes de adição de padrão apresentaram recuperação entre 95 e 109 %. Outras características importantes tais como desvio padrão relativo em torno de 2% (n = 8) e freqüência de amostragem de 60 determinações por hora foram observadas. / In this work it was developed an automatic procedure for the determination of selenium in ration for domestic animals digested in acidic medium. The automated method was based on the catalytic effect caused by selenium (IV) on the reaction of ammoniacal iron sulfate with EDTA in medium containing NaNO3. The analytical module was based on multicommuted flow process. Considering that the kinetic of reaction was slow, the analytical module was designed with six reaction coupled in parallel in order to allow that residence time of sample zone was increased up to 5 min without decrease of the analytical throughput. After definition of the system control variables, sample of animal ration mineralized in nitric/perchloric acid medium were processed. The results concerning to standard solution addition assays gave recoveries between the range of 95 % up to 109 %. Other profitable features such as a relative standard deviation of 2 % (n = 8) and an analytical throughput of 60 samples determination per hours were also achieved.
109

Interação de Íons de manganês, em diferentes estados de oxidação, com íon azoteto / On the interaction between azide and manganese ions at several oxidation states

Moya, Horacio Dorigan 19 June 1998 (has links)
Realizaram-se estudos potenciométricos, em combinação com medições espectrofotométricas, para caracterizar a espécie de íon manganês obtida a partir de oxidação coulométrica a corrente constante utilizando-se solução de Mn(II) (0,050 mol.L-1) em N3- (0,50 a 2,0 mol.L-1) e H+ (0,01 mol.L-1). Graficamente foi possível concluir que a espécie gerada é Mn(III) e obter os valores dos potenciais condicionais de redução, E0\'x, do par Mn(III)/Mn(II), em soluções tampão N3-/HN3, de concentração de N3- 0,50; 1,0; 1,5; 2,0 e 4,0 mol.L-1 e H+ 0,010 mol.L-1, sendo 0,468, 0,421, 0,396, 0,377 e 0,336 V (vs. ECS), respectivamente. Esses valores de E0\'x permitiram o cálculo das constantes de equilíbrio para os complexos no sistema Mn(III)/N3-, sendo: &#946;1 = 1,23.105 M-1, &#946;2 = 6,03.108 M-2, &#946;3 = 2,37.1011 M-3, &#946;4 = 1,54.1011 M-4 e &#946;5 = 9,57.1011 M-5 (T = 25,0 &#177; 0,1 &#186;C, I = 2,0 mol.L-1 com NaClO4). Os valores calculados para as absortividades molares, em 430 nm, para as espécies [Mn(N3)3], [Mn(N3)4]- e [Mn(N3)5]2- foram 226, 3.680 e 6560 mol-1.L.cm-1, respectivamente. Para o estudo do cátion Co(II), foram efetuadas oxidações coulométricas da mesma forma e nas mesmas condições que para o cátion Mn(II). Os valores de E0\'x encontrados para o par Co(III)/Co(II) foram 0,400, 0,338, 0,302, 0,277 e 0,228 V (vs. ECS), para as concentrações de N3- 0,50; 1,0; 1,5; 2,0 e 4,0 mol.L-1 e H+ 0,010 mol.L-1. Com os valores de E0\'x obtidos para os pares Co(III)/Co(II) e Mn(III)/Mn(II), calcularam-se as constante de equilíbrio global, K, para a reação redox entre [Co(N3)n]3-n e [Mn(N3)n]2-n, encontrando-se os valores 7,1xl0-2, 4,0x10-2, 2,6x10-2, 2,0x10-2 e l,5x10-2, para os tampões acima descritos, respectivamente. Outros estudos revelaram a possível formação da espécies Mn(VI) quando KMnO4 e K2MnO4 são adicionados, separadamente, a uma solução tampão azoteto, por exemplo, N3- = 1,5 mol.L-1 e HN3 = 0,05 mol.L-1. / Spectrophotometric studies combined with coulometric generation of Mn(III), in presence of large excess of Mn(II), showed a maximum absorbance peak at 430 nm. The average molar absorptivity increases with azide concentration (0.44 to 3.9 mol.L-1) from 3,100 to 6,300 mol-1.L.cm-1, showing a stepwise complex formation. Potential measurements of the Mn(III)/Mn(II) system in several azide aqueous buffers solutions: 1.0x10-2 mol.L-1 HN3, (0.50 to 2.0 mol.L-1) N3- and 5.0x10-1 mol.L-1 Mn(II) and constant ionic strength 2.0 mol.L-1, kept with sodium perchlorate, leads to the conditional potential, E0\'x, in several azide concentrations at 25.0 &#177; 0.1 &#186;C (0.468, 0.421, 0.396, 0.377 e 0.336 V (vs. SCE) for the 0.50; 1.0; 1.5; 2.0 and 4.0 mol.L-1 N3- concentration, respectively). Considering the overall formation constants of Mn(II)/N3-, from former studies, and the potential, E0\'s = 1.063 V vs. SCE, for Mn(III)/Mn(II) system in non-complexing medium, it was possible to calculate the Fronaeus function, F0(L), and the following overall formation constants: &#946;1 = 1.2x105 M-1, &#946;2 = 6.0x108 M-2, &#946;3 = (2.4&#177;0.7)x1011 M-3, &#946;4 = (1.5&#177;0.5)x1011 M-4 and &#946;5 = (9.6&#177;.0.8)x1011 M-5 for the Mn(III)/N3- complexes. The molar absorptivity values, at 430 nm, found for the species [Mn(N3)3], [Mn(N3)4]- and [Mn(N3)5]2- were 226, 3,680 and 6,560 mol-1.L.cm-1, respectively. Similar studies with Co(II) in the same conditions, lead to the following conditional potentials, E0\'x, for the Co(III)/Co(II) system: 0.400, 0.338, 0.302, 0.277 e 0.228 V (vs. SCE). Using the E0\'x values obtained for both systems, Co(III)/Co(II) and Mn(III)/Mn(II), it was possible to calculate the equilibrium constant for the redox reaction between [Co(N3)n]3-n and [Mn(N3)n]2-n. The values found were 7.1xl0-2, 4.0x10-2, 2.6x10-2, 2.0x10-2 and 1.5x10-2, for 0.50; 1.0; 1.5; 2.0 and 4.0 mol.L-1 N3- concentration, respectively, in the same acidity (1.0x10-2 mol.L-1 HN3).
110

Estudo comparativo entre as tecnicas de voltametria em pulso diferencial, Espectrofotometria no ultravioleta e visivel e Cromatografia liquida de alta eficiencia como metodologias analiticas no doseamento da substancia quimica Paracetamol

Santos, Luciana Oliveira dos. January 2003 (has links)
Mestre -- Instituto Nacional de Controle de Qualidade em Saude, Rio de Janeiro, 2003.

Page generated in 0.0534 seconds