• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • Tagged with
  • 19
  • 19
  • 13
  • 13
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Cognição, humor e atividades funcionais em pacientes com doença de Parkinson submetidos à estimulação cerebral profunda bilateral em núcleo subtalâmico / Cognition, mood and activities of daily living assessment in patients with Parkinson\'s disease submitted to bilateral deep brain stimulation in the subthalamic nucleus

Alessandra Shenandoa Heluani 29 October 2014 (has links)
Introdução: A estimulação cerebral profunda (DBS) tem sido utilizada para controle das alterações motoras nos pacientes com Doença de Parkinson (DP). O núcleo subtalâmico (NST) é o alvo preferencialmente escolhido na cirurgia. Entretanto, a técnica tem sido associada com declínio cognitivo, principalmente na fluência verbal, alterações de humor e de comportamento. Objetivo: Verificar a ocorrência de alterações na cognição, humor e atividades funcionais por meio de avaliação neuropsicológica. Métodos: Vinte e um pacientes submetidos à cirurgia no período de Maio de 2008 a Março de 2013 foram examinados por meio da avaliação neuropsicológica incluindo testes de memória, funções executivas, funções atencionais, linguagem, praxia, escala hospitalar de depressão e ansiedade (HADS) e atividades funcionais (Pfeffer), nas fases pré e pós-operatória. Os dados foram analisados utilizando SPSS versão 17.0 e os resultados foram comparados através do teste pareado t-Student ou chi-quadrado. Foi adotado um nível de significância igual ou menor que 5% (p < 0,05) para todas as análises. Resultados: Não foram encontradas diferenças significativas nas funções cognitivas, no humor e nas atividades funcionais avaliadas. Resultado marginal foi observado na memória episódica imediata verbal (p=0,051). Conclusão: DBS-NST parece não ter impacto negativo nas funções cognitivas e humor. Apesar da amostra ser relativamente pequena, a técnica parece ser segura do ponto de visto cognitivo em pacientes adequadamente selecionados / Introdution: Deep brain stimulation (DBS) has been used for control of motor disorders in patients with Parkinson\'s disease (PD). The subthalamic nucleus (STN) is the main target used in surgery. However, the technique has been associated with cognitive decline, mainly in verbal fluency, mood and behavior. Objective: To investigate the occurrence of changes in cognition, mood, and activities of daily living through neuropsychological assessment. Methods: Twenty one patients operated between May, 2008 and March, 2013 were submitted to pre- and post-operative neuropsychological testing including memory, executive functions, attentional functions, language and praxis assessment, and to hospital anxiety and depression scale (HADS) and activities of daily living (Pfeffer) scale rating as well. Data were analyzed using SPSS version 17.0 and the results were compared using the paired Student t-test or chi-square. A significance level equal or lower than 5% (p < 0.05) was adopted. Results: No significant differences were found in cognitive functions, mood and activities of daily living. Marginal results were observed in immediate verbal episodic memory (p=0.051). Conclusion: DBS - STN did not show a negative impact on cognitive function, mood and daily activities. Despite the relatively small sample, the technique appears to be safe from the cognitive point of view in appropriately selected patients
12

Efeito do treino de marcha em esteira com e sem suporte de peso em pacientes com doença de Parkinson em uso de estimulação cerebral profunda / Effects of treadmill training with and without body weight support in Parkinson\'s Disease patients in use of deep brain stimulation

Luna, Natália Mariana Silva 02 July 2015 (has links)
Introdução: A disfunção da marcha é um dos maiores comprometimentos funcionais do paciente com a doença de Parkinson (DP). A estimulação cerebral profunda do núcleo subtalâmico tem mostrado melhora da marcha e equilíbrio. Esse efeito pode ser mantido e potencializado por programas de reabilitação motora específicos, como o treino em esteira sem e com suporte de peso corporal. No entanto, faltam estudos desses treinos em pacientes com a DP em uso desta estimulação. Objetivo: Comparar parâmetros cinemáticos lineares e angulares da marcha de pacientes com a DP em uso de estimulação cerebral profunda bilateral do núcleo subtalâmico, antes e após dois treinamentos: esteira sem e com suporte de peso corporal, associados à cinesioterapia convencional. Métodos: 12 pacientes (60,9 ± 10,6 anos; 20 ± 7 anos de doença e 20 ± 4 meses de tempo de cirurgia) completaram ambos os treinos em estudo cruzado fixo. Os pacientes passaram por 8 semanas de treino de marcha em esteira sem suporte de peso corporal e programa de cinesioterapia convencional, seguidas por 6 semanas de período sem intervenção. Posteriormente, realizaram 8 semanas de treino de marcha em esteira com suporte de peso corporal e o mesmo programa de cinesioterapia regular. As intervenções tiveram frequência de duas vezes por semana e duração de 90 minutos por sessão. A análise cinemática da marcha envolveu oito câmeras infravermelhas que detectaram 19 marcadores reflexivos nos membros inferiores dos pacientes. A análise estatística utilizou o teste Wilcoxon e foi adotado valor de p <= 0,05 como estatisticamente significante. Resultados: Ambos os treinos não mostraram diferenças significativas nos parâmetros lineares. Após o treino com suporte, observou-se aumento significativo dos seguintes parâmetros angulares: amplitude de movimento da pelve (inclinação, obliquidade e rotação); amplitude de movimento do quadril (abduçãoadução e rotação); % da fase de balanço que corresponde à flexão máxima do joelho e amplitude de movimento da progressão do pé. Conclusão: O treino em esteira com suporte de peso corporal mostrou capacidade de promover mudanças em parâmetros cinemáticos angulares da marcha. As implicações do treino em suspensão podem ter sido somadas aos efeitos neurofisiológicos da estimulação cerebral profunda e então desencadeado a melhora da mobilidade dos membros inferiores durante a marcha / Introduction: Gait disturbance is one of the hallmark features of Parkinson\'s disease (PD). Subthalamic nucleus deep brain stimulation (DBS) has shown improvements in gait and balance, and this effect can be maintained and enhanced by specific motor rehabilitation programs, such treadmill training without and with body weight support. However, at present there is a paucity of research on these combined interventions in PD with of this stimulation. Objective: To compare training-induced changes in gait linear and angular kinematic parameters among patients with PD who have used bilateral subthalamic nucleus DBS, and a combined intervention of conventional physical therapy with either treadmill training with body weight support or without support. Methods: 12 patients (age: 60.9 ± 10.6 years; disease duration: 20 ± 7 years; and time since DBS surgery: 20 ± 4 months) completed both training protocols in a fixed cross-over design. All patients received 8 weeks of treadmill training without body weight support in conjunction with conventional physical therapy, followed by a 6 weeks wash out period of no training. Thereafter, all patients received 8 weeks of body weight support treadmill training, in conjunction with the same conventional physical therapy. Both interventions had a frequency of two times per week, and duration of 90 minutes per session. Gait kinematic analysis involved eight infrared cameras that detected 19 reflective spherical markers attached to the limb lower of patients. Statistical analysis used the Wilcoxon and was adopted the value of p <= 0,05 as statistically significant. Results: Both the training no showed significant differences in linear parameters. After the body weight support training, observed there was a significant increase in following angular parameters: pelvis\' range of motion (tilt, obliquity, rotation); hip\'s range of motion (abduction-adduction and rotation); % Knee maximal flexion on Swing phase and foot progression\' range of motion. Conclusion: Treadmill training with body weight support showed an ability to promote changes in gait angular kinematic parameters. The implications of this training may have been added to the neurophysiological effects of DBS and then triggered the improved of mobility of lower limbs during gait
13

Efeitos adversos produzidos pela estimulação cerebral profunda aguda do núcleo subtalâmico e suas correlações com características neuroanatômicas, localização do eletrodo e parâmetros de estimulação / Side effects produced by acute deep brain stimulation of the subthalamic nucleus and their correlations with neuroanatomic characteristics, electrode location and stimulation parameters

Matias, Caio César Marconato Simões 01 July 2016 (has links)
A estimulação cerebral profunda do núcleo subtalâmico (NST) é um tratamento bem estabelecido para os sintomas refratários à medicação em paciente com doença de Parkinson avançada. Além do procedimento de implante, a programação dos eletrodos é uma etapa fundamental para atingir os resultados desejados. A primeira etapa da programação é estabelecer os limiares para efeitos adversos. Contudo, a correlação entre a localização do eletrodo e o limiar para efeitos adversos associados à estimulacao das estruturas adjacentes ainda não é bem estabelecida. Características neuroanatômicas e a localização dos eletrodos foram identificadas utilizando-se um programa de planejamento de cirurgia estereotáxica, enquanto os parâmetros de estimulação e os efeitos adversos foram obtidos dos prontuários médicos. As correlações entre estas variáveis foram testadas através de análises univariadas e análises multivariadas. Estimulação monopolar produziu efeitos adversos capsulares (EA-C) em 208 dos 316 contatos (65,8%) e efeitos adversos não-capsulares (EA-NC) em 223 dos 316 contatos (70,6%). A ocorrência de EA-C esteve associada com o número do contato (p = 0,009) e com a coordenada \"Z\" (p = 0,03), enquanto o limiar de voltagem para EA-C esteve correlacionado com o ângulo da cápsula interna (p = 0,035). A ocorrência de EA-NC esteve associada com o número do contato (p = 0,005), \"X\" (p = 0,03), \"Y\" (p = 0,004) e com a distância para o núcleo rubro (p = 0,001 e p = 0,003). Houve correlação entre o limiar de voltagem para EA-NC e o ângulo da cápsula interna (p = 0,006), o ângulo coronal do eletrodo (p = 0,02), \"X\" (p = 0,001), \"Y\" (p < 0,001), \"Z\" (p < 0,001) e com as distâncias para a cápsula interna (p = 0,02) e para o núcleo rubro (p = 0,004 e p < 0,001). EA-C estiveram associados com os contatos mais distais do eletrodo e com localização mais profunda, bem como com maior angulação da cápsula interna. EA-NC estiveram associados com os contatos mais distais do eletrodo, localizados mais medial, posterior e inferiormente e mais próximos do núcleo rubro. Ademais, houve associação entre EA-NC e eletrodos implantados com maior ângulo coronal, bem como com maior angulação da cápsula interna. Estes achados poderão ser úteis no desenvolvimento de novas estratégias para o planejamento do implante de eletrodos de estimulação cerebral profunda. / Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a well-established treatment for medically refractory motor symptoms of patients with advanced Parkinson\'s disease. Programming of the device is as relevant to patient outcome as accurate implantation of the electrodes. The first step of DBS programming is to identify the thresholds to side effects. However, the relationship between lead location and the threshold to adverse effects is not fully understood. Anatomical measurements and electrode location were evaluated on a stereotactic surgical planning software, whereas stimulation parameters and side effects were obtained from medical records. Correlations among these variables were tested using univariate and multivariable analyses. Monopolar stimulation elicited capsular side effects (CSEs) in 208 of 316 contacts (65.8%) and noncapsular side effects (NCSEs) in 223 of 316 contacts (70.6%). The occurrence of CSEs was correlated with contact number (p = 0,009) and with the \"Z\" coordinate (p = 0,03), whereas voltage threshold to CSEs exhibited correlation with the internal capsule angle (p = 0,035). The occurrence of NCSEs was correlated with contact number (p = 0,005), \"X\" (p = 0,03), \"Y\" (p = 0,004), and the distance to the red nucleus (p = 0,001 and p = 0,003). There was correlation between voltage threshold to NCSEs and the internal capsule angle (p = 0,006), electrode\'s coronal angle (p = 0,02), \"X\" (p = 0,001), \"Y\" (p < 0,001), \"Z\" (p < 0,001), and the distances to the internal capsule (p = 0,02) and to the red nucleus (p = 0,004 and p < 0,001). CSEs were associated with more distally contacts, with deeper localization, as well as with greater internal capsule angles. NCSEs were associated with more distally contacts, with localization more medial, posterior and inferior, and closer to the red nucleus. Moreover, there was a correlation between NCSEs and electrodes implanted with greater coronal angles, as well as with greater internal capsule angles. These findings can be useful to inform novel targeting strategies for deep brain stimulation lead implantation.
14

Efeitos adversos produzidos pela estimulação cerebral profunda aguda do núcleo subtalâmico e suas correlações com características neuroanatômicas, localização do eletrodo e parâmetros de estimulação / Side effects produced by acute deep brain stimulation of the subthalamic nucleus and their correlations with neuroanatomic characteristics, electrode location and stimulation parameters

Caio César Marconato Simões Matias 01 July 2016 (has links)
A estimulação cerebral profunda do núcleo subtalâmico (NST) é um tratamento bem estabelecido para os sintomas refratários à medicação em paciente com doença de Parkinson avançada. Além do procedimento de implante, a programação dos eletrodos é uma etapa fundamental para atingir os resultados desejados. A primeira etapa da programação é estabelecer os limiares para efeitos adversos. Contudo, a correlação entre a localização do eletrodo e o limiar para efeitos adversos associados à estimulacao das estruturas adjacentes ainda não é bem estabelecida. Características neuroanatômicas e a localização dos eletrodos foram identificadas utilizando-se um programa de planejamento de cirurgia estereotáxica, enquanto os parâmetros de estimulação e os efeitos adversos foram obtidos dos prontuários médicos. As correlações entre estas variáveis foram testadas através de análises univariadas e análises multivariadas. Estimulação monopolar produziu efeitos adversos capsulares (EA-C) em 208 dos 316 contatos (65,8%) e efeitos adversos não-capsulares (EA-NC) em 223 dos 316 contatos (70,6%). A ocorrência de EA-C esteve associada com o número do contato (p = 0,009) e com a coordenada \"Z\" (p = 0,03), enquanto o limiar de voltagem para EA-C esteve correlacionado com o ângulo da cápsula interna (p = 0,035). A ocorrência de EA-NC esteve associada com o número do contato (p = 0,005), \"X\" (p = 0,03), \"Y\" (p = 0,004) e com a distância para o núcleo rubro (p = 0,001 e p = 0,003). Houve correlação entre o limiar de voltagem para EA-NC e o ângulo da cápsula interna (p = 0,006), o ângulo coronal do eletrodo (p = 0,02), \"X\" (p = 0,001), \"Y\" (p < 0,001), \"Z\" (p < 0,001) e com as distâncias para a cápsula interna (p = 0,02) e para o núcleo rubro (p = 0,004 e p < 0,001). EA-C estiveram associados com os contatos mais distais do eletrodo e com localização mais profunda, bem como com maior angulação da cápsula interna. EA-NC estiveram associados com os contatos mais distais do eletrodo, localizados mais medial, posterior e inferiormente e mais próximos do núcleo rubro. Ademais, houve associação entre EA-NC e eletrodos implantados com maior ângulo coronal, bem como com maior angulação da cápsula interna. Estes achados poderão ser úteis no desenvolvimento de novas estratégias para o planejamento do implante de eletrodos de estimulação cerebral profunda. / Deep brain stimulation (DBS) of the subthalamic nucleus (STN) is a well-established treatment for medically refractory motor symptoms of patients with advanced Parkinson\'s disease. Programming of the device is as relevant to patient outcome as accurate implantation of the electrodes. The first step of DBS programming is to identify the thresholds to side effects. However, the relationship between lead location and the threshold to adverse effects is not fully understood. Anatomical measurements and electrode location were evaluated on a stereotactic surgical planning software, whereas stimulation parameters and side effects were obtained from medical records. Correlations among these variables were tested using univariate and multivariable analyses. Monopolar stimulation elicited capsular side effects (CSEs) in 208 of 316 contacts (65.8%) and noncapsular side effects (NCSEs) in 223 of 316 contacts (70.6%). The occurrence of CSEs was correlated with contact number (p = 0,009) and with the \"Z\" coordinate (p = 0,03), whereas voltage threshold to CSEs exhibited correlation with the internal capsule angle (p = 0,035). The occurrence of NCSEs was correlated with contact number (p = 0,005), \"X\" (p = 0,03), \"Y\" (p = 0,004), and the distance to the red nucleus (p = 0,001 and p = 0,003). There was correlation between voltage threshold to NCSEs and the internal capsule angle (p = 0,006), electrode\'s coronal angle (p = 0,02), \"X\" (p = 0,001), \"Y\" (p < 0,001), \"Z\" (p < 0,001), and the distances to the internal capsule (p = 0,02) and to the red nucleus (p = 0,004 and p < 0,001). CSEs were associated with more distally contacts, with deeper localization, as well as with greater internal capsule angles. NCSEs were associated with more distally contacts, with localization more medial, posterior and inferior, and closer to the red nucleus. Moreover, there was a correlation between NCSEs and electrodes implanted with greater coronal angles, as well as with greater internal capsule angles. These findings can be useful to inform novel targeting strategies for deep brain stimulation lead implantation.
15

Efeito do treino de marcha em esteira com e sem suporte de peso em pacientes com doença de Parkinson em uso de estimulação cerebral profunda / Effects of treadmill training with and without body weight support in Parkinson\'s Disease patients in use of deep brain stimulation

Natália Mariana Silva Luna 02 July 2015 (has links)
Introdução: A disfunção da marcha é um dos maiores comprometimentos funcionais do paciente com a doença de Parkinson (DP). A estimulação cerebral profunda do núcleo subtalâmico tem mostrado melhora da marcha e equilíbrio. Esse efeito pode ser mantido e potencializado por programas de reabilitação motora específicos, como o treino em esteira sem e com suporte de peso corporal. No entanto, faltam estudos desses treinos em pacientes com a DP em uso desta estimulação. Objetivo: Comparar parâmetros cinemáticos lineares e angulares da marcha de pacientes com a DP em uso de estimulação cerebral profunda bilateral do núcleo subtalâmico, antes e após dois treinamentos: esteira sem e com suporte de peso corporal, associados à cinesioterapia convencional. Métodos: 12 pacientes (60,9 ± 10,6 anos; 20 ± 7 anos de doença e 20 ± 4 meses de tempo de cirurgia) completaram ambos os treinos em estudo cruzado fixo. Os pacientes passaram por 8 semanas de treino de marcha em esteira sem suporte de peso corporal e programa de cinesioterapia convencional, seguidas por 6 semanas de período sem intervenção. Posteriormente, realizaram 8 semanas de treino de marcha em esteira com suporte de peso corporal e o mesmo programa de cinesioterapia regular. As intervenções tiveram frequência de duas vezes por semana e duração de 90 minutos por sessão. A análise cinemática da marcha envolveu oito câmeras infravermelhas que detectaram 19 marcadores reflexivos nos membros inferiores dos pacientes. A análise estatística utilizou o teste Wilcoxon e foi adotado valor de p <= 0,05 como estatisticamente significante. Resultados: Ambos os treinos não mostraram diferenças significativas nos parâmetros lineares. Após o treino com suporte, observou-se aumento significativo dos seguintes parâmetros angulares: amplitude de movimento da pelve (inclinação, obliquidade e rotação); amplitude de movimento do quadril (abduçãoadução e rotação); % da fase de balanço que corresponde à flexão máxima do joelho e amplitude de movimento da progressão do pé. Conclusão: O treino em esteira com suporte de peso corporal mostrou capacidade de promover mudanças em parâmetros cinemáticos angulares da marcha. As implicações do treino em suspensão podem ter sido somadas aos efeitos neurofisiológicos da estimulação cerebral profunda e então desencadeado a melhora da mobilidade dos membros inferiores durante a marcha / Introduction: Gait disturbance is one of the hallmark features of Parkinson\'s disease (PD). Subthalamic nucleus deep brain stimulation (DBS) has shown improvements in gait and balance, and this effect can be maintained and enhanced by specific motor rehabilitation programs, such treadmill training without and with body weight support. However, at present there is a paucity of research on these combined interventions in PD with of this stimulation. Objective: To compare training-induced changes in gait linear and angular kinematic parameters among patients with PD who have used bilateral subthalamic nucleus DBS, and a combined intervention of conventional physical therapy with either treadmill training with body weight support or without support. Methods: 12 patients (age: 60.9 ± 10.6 years; disease duration: 20 ± 7 years; and time since DBS surgery: 20 ± 4 months) completed both training protocols in a fixed cross-over design. All patients received 8 weeks of treadmill training without body weight support in conjunction with conventional physical therapy, followed by a 6 weeks wash out period of no training. Thereafter, all patients received 8 weeks of body weight support treadmill training, in conjunction with the same conventional physical therapy. Both interventions had a frequency of two times per week, and duration of 90 minutes per session. Gait kinematic analysis involved eight infrared cameras that detected 19 reflective spherical markers attached to the limb lower of patients. Statistical analysis used the Wilcoxon and was adopted the value of p <= 0,05 as statistically significant. Results: Both the training no showed significant differences in linear parameters. After the body weight support training, observed there was a significant increase in following angular parameters: pelvis\' range of motion (tilt, obliquity, rotation); hip\'s range of motion (abduction-adduction and rotation); % Knee maximal flexion on Swing phase and foot progression\' range of motion. Conclusion: Treadmill training with body weight support showed an ability to promote changes in gait angular kinematic parameters. The implications of this training may have been added to the neurophysiological effects of DBS and then triggered the improved of mobility of lower limbs during gait
16

Estimulação transcraniana por corrente continua na fase aguda do episódio depressivo maior: uma meta-análise de dados individuais / Transcranial direct current stimulation for acute major depressive episodes: meta-analysis of individual patient data

Moffa, Adriano Henrique de Matos 30 May 2016 (has links)
Introdução: A Estimulação Transcraniana por Corrente Contínua (ETCC) é uma intervenção não farmacológica com resultados discordantes quanto à sua eficácia para o tratamento do Episódio Depressivo Maior (EDM). Possivelmente devido a heterogeneidade dos estudos, as três meta-análises publicadas até agora sobre o assunto apontam para uma pequena vantagem a favor da técnica, dependendo da variável de desfecho analisada (melhora de depressão ou resposta). Todas essas meta-análises utilizaram dados agregados. Focamo-nos, no presente estudo, na realização de uma revisão sistemática da literatura e de uma meta-análise baseada em dados individuais de pacientes (MA-DIP) com Depressão Maior (DM) submetidos à ETCC na fase aguda. Este tipo de análise é mais preciso na avaliação da eficácia de uma intervenção e na obtenção dos preditores de respostas de tratamento, já que as características individuais de cada sujeito são consideradas ao invés das médias e frequências, como nas meta-análises de dados agregados. Objetivos: (1) avaliar a eficácia da ETCC na fase aguda da DM, (2) identificar preditores de resposta, remissão e melhora da depressão específicos e (3) avaliar a aceitabilidade da intervenção. Resultados: Os dados foram colecionados de 6 ensaios clínicos randomizados placebo controlados, totalizando 289 sujeitos. A ETCC ativa foi estatisticamente superior à estimulação simulada em relação à resposta (34% vs. 19%, respectivamente; RC=2,44, IC 95% = 1,38-4,32, NNT=7), remissão (23,1% vs. 12,7%, respectivamente; RC= 2,38, IC 95% = 1,22 - 4,64, NNT=9) e melhora da depressão (coeficiente = 0,35, IC 95% =0,12 0,57). Demonstrou-se que após ajustes para outros preditores e confundidores, depressão resistente a tratamento e doses mais altas de ETCC foram, respectivamente, inversa e diretamente associadas com a eficácia da ETCC. Conclusões: O tamanho de efeito do tratamento com ETCC foi comparável àqueles reportados, em outros estudos, para a Estimulação Magnética Transcraniana repetitiva (EMTr) e para o tratamento farmacológico (com antidepressivos tricíclicos e inibidores seletivos de recaptação de serotonina) na atenção primária para depressão. Os parâmetros mais importantes para otimização em ensaios clínicos futuros são a refratariedade da depressão e a dose da ETCC / Introduction: Transcranial direct current stimulation (tDCS) is a nonpharmacological intervention for depression. Randomised, sham-controlled clinical trials (RCTs) conducted hitherto have presented mixed results regarding its efficacy. Although recent meta-analyses suggest some efficacy when measuring depression symptoms using a continuous outcome, these meta-analyses were limited in their results as they used an aggregate data approach. We aimed therefore to perform an individual patient data (IPD) meta-analysis. In contrast to an aggregate data meta-analysis, an IPD approach uses the raw data of each participant within a study. IPD is more accurate in estimating the efficacy of an intervention since aggregate data meta-analyses present only summary estimates of efficacy. IPD meta-analysis is also superior to the aggregate data approach for obtaining predictors of treatment outcome, as the characteristics of each patient are assessed instead of the mean and frequency values obtained in the traditional aggregate data meta-analysis. Objectives (a) To provide precise estimates of tDCS efficacy based on continuous (depression improvement) and categorical (response and remission rates) outcomes, (b) to identify variables associated with tDCS efficacy and (c) to estimate the treatment acceptability. Results: Data were gathered from six randomised sham-controlled trials, enrolling 289 patients. Active tDCS was significantly superior to sham for response (34% v. 19%, respectively, odds ratio (OR) = 2.44, 95% CI 1.384.32, number needed to treat (NNT) = 7), remission (23.1% v. 12.7%, respectively, OR = 2.38, 95% CI 1.224.64, NNT = 9) and depression improvement ( coefficient 0.35, 95% CI 0.120.57). Mixed effects models showed that, after adjustment for other predictors and confounders, treatment-resistant depression and higher tDCS doses were, respectively, negatively and positively associated with tDCS efficacy. Conclusions: The effect size of tDCS treatment was comparable with those reported for repetitive transcranial magnetic stimulation (rTMS) and antidepressant drug treatment in primary care. The most important parameters for optimisation in future trials are depression refractoriness and tDCS dose
17

Plano de segurança do paciente para pacientes com sistemas de estimulação encefálica profunda submetidos a exames de imagem por ressonância magnética no Hospital Marcelino Champagnat / Patient safety plan for patients with deep brain stimulation systems undergoing to magnetic resonance imaging scans at the Hospital Marcelino Champagnat

Ramos, Maria Manuela de Andrade e Silva 29 February 2016 (has links)
Em 2013, foi implantado no Brasil o Programa Nacional de Segurança do Paciente (PNSP), que através da Resolução RDC No 36, prevê que as instituições de saúde brasileiras devem apresentar um Plano de Segurança do Paciente (PSP) para as situações que possam proporcionar a ocorrência de eventos adversos (EAs), ou seja, lesão ou dano não intencional causado ao paciente pela intervenção assistencial e não pela doença base. O PSP é um documento com embasamento científico que aponta as situações de risco e descreve estratégias e ações definidas pelo serviço de saúde para a gestão do risco com objetivo de prevenção e redução dos EA em todas as fases da assistência. O implante de eletrodos para estimulação encefálica profunda (EEP) é um procedimento realizado rotineiramente no Hospital Marcelino Champagnat (HMC), localizado na cidade de Curitiba – PR, para melhorar a sintomatologia e a qualidade de vida de pacientes portadores de determinados distúrbios neurológicos crônicos. A confiabilidade e a precisão do posicionamento dos eletrodos cerebrais após a implantação de sistemas de EEP é de suma importância para a eficácia do método, sendo a Imagem por Ressonância Magnética (IRM) pós-operatória, atualmente, o padrão ouro para documentação do correto posicionamento dos eletrodos. Entretanto, a interação do sistema de EEP com o campo de radiofrequência do equipamento de IRM pode constituir uma fonte de EAs, uma vez que possibilita a indução de correntes elétricas com potencial de causar lesões térmicas ao paciente em locais de alta resistência. As recomendações de segurança dos fabricantes para a maioria dos sistemas de EEP implantados são bastante restritivas e resultam em longos tempos de exame ou em imagens de baixa qualidade, fatores que dificultam a prática em muitos centros. Estudos in vitro revelam que o aquecimento excessivo ocorre sob determinadas configurações, enquanto outras não oferecem risco fisiológico ao paciente. Estudos clínicos com base em vasta experiência sustentam a evidência de que é possível realizar exames pós-operatórios de forma satisfatória e sem a ocorrência de EAs utilizando parâmetros menos restritivos que aqueles determinados pelos fabricantes, desde que alguns padrões de segurança sejam cuidadosamente seguidos. Dessa forma, o presente trabalho propõe a elaboração de um PSP para a situação específica de pacientes com sistemas de EEP submetidos à exames de IRM no HMC, com base nas recomendações de segurança do fabricante e na revisão sistemática da literatura. De acordo com a base de dados consultada, um total de 26 artigos científicos foram considerados relevantes e permitiram identificar as possíveis fontes de risco de forma a evitá-las, colaborando com a conclusão satisfatória do PSP. Além de suprir a demanda local, o presente trabalho visou também promover a cultura de segurança do paciente e despertar a atenção para a necessidade de interposição de barreiras às diversas oportunidades de EAs que os setores de radiologia podem oferecer. A metodologia aqui proposta pode servir, ainda, de base para que outros centros de diagnóstico por imagem componham seus próprios PSPs. / In 2013, the National Program Patient Safety (PNSP) was implemented in Brazil through Resolution RDC 36, providing that the Brazilian health institutions must have a Patient Safety Plan (PSP) for situations that may lead to adverse events (AEs), which are unintentional injury or damage caused to the patient by the health care intervention and not by the primary disease. The PSP is a document with scientific basis that points to hazardous situations and describes strategies and actions defined by the health service for risk management in order to prevent and reduce AEs in all phases of patient care. Implantation of Deep Brain Stimulation (DBS) devices is considered a routine procedure at the Hospital Marcelino Champagnat (HMC), located in Curitiba – PR, and it consists in a practice widely used to improve symptoms and quality of life of patients with certain chronic neurological disorders.The reliability and accuracy of the final brain positioning of the leads, after the DBS implantation are of paramount importance to assure efficacy. Currently, post-operative Magnetic Resonance Imaging (MRI) is the gold standard for the documentation of the correct lead positioning. However, the interaction between the DBS system and the MRI radiofrequency field could represent an important source of adverse events (EAs) since it allows electric currents induction with potential to cause local thermal injuries on high resistance sites. The safety recommendations from the DBS system manufacturers for most of the already deployed systems are quite restrictive resulting in long examination times or low quality images, which compromises the practice in many centers. Thus, the present work proposes the development of a PSP based on the manufacturer's safety recommendations and a systematic review of the literature to the specific situation of patients with DBS systems undergoing MRI scans at the HMC. We found a total of 26 papers, that were considered relevant and allowed us to identify the potential sources of risk in order to avoid them, collaborating to the successful elaboration of the PSP. Besides supplying local demand, this work also aims to promote patient safety and draw attention to the need of interposing barriers in order to avoid significant AEs situations that a radiology department may be presented with. Moreover, the methodology proposed here can serve as a basis for other imaging centers to compose their own PSPs.
18

Plano de segurança do paciente para pacientes com sistemas de estimulação encefálica profunda submetidos a exames de imagem por ressonância magnética no Hospital Marcelino Champagnat / Patient safety plan for patients with deep brain stimulation systems undergoing to magnetic resonance imaging scans at the Hospital Marcelino Champagnat

Ramos, Maria Manuela de Andrade e Silva 29 February 2016 (has links)
Em 2013, foi implantado no Brasil o Programa Nacional de Segurança do Paciente (PNSP), que através da Resolução RDC No 36, prevê que as instituições de saúde brasileiras devem apresentar um Plano de Segurança do Paciente (PSP) para as situações que possam proporcionar a ocorrência de eventos adversos (EAs), ou seja, lesão ou dano não intencional causado ao paciente pela intervenção assistencial e não pela doença base. O PSP é um documento com embasamento científico que aponta as situações de risco e descreve estratégias e ações definidas pelo serviço de saúde para a gestão do risco com objetivo de prevenção e redução dos EA em todas as fases da assistência. O implante de eletrodos para estimulação encefálica profunda (EEP) é um procedimento realizado rotineiramente no Hospital Marcelino Champagnat (HMC), localizado na cidade de Curitiba – PR, para melhorar a sintomatologia e a qualidade de vida de pacientes portadores de determinados distúrbios neurológicos crônicos. A confiabilidade e a precisão do posicionamento dos eletrodos cerebrais após a implantação de sistemas de EEP é de suma importância para a eficácia do método, sendo a Imagem por Ressonância Magnética (IRM) pós-operatória, atualmente, o padrão ouro para documentação do correto posicionamento dos eletrodos. Entretanto, a interação do sistema de EEP com o campo de radiofrequência do equipamento de IRM pode constituir uma fonte de EAs, uma vez que possibilita a indução de correntes elétricas com potencial de causar lesões térmicas ao paciente em locais de alta resistência. As recomendações de segurança dos fabricantes para a maioria dos sistemas de EEP implantados são bastante restritivas e resultam em longos tempos de exame ou em imagens de baixa qualidade, fatores que dificultam a prática em muitos centros. Estudos in vitro revelam que o aquecimento excessivo ocorre sob determinadas configurações, enquanto outras não oferecem risco fisiológico ao paciente. Estudos clínicos com base em vasta experiência sustentam a evidência de que é possível realizar exames pós-operatórios de forma satisfatória e sem a ocorrência de EAs utilizando parâmetros menos restritivos que aqueles determinados pelos fabricantes, desde que alguns padrões de segurança sejam cuidadosamente seguidos. Dessa forma, o presente trabalho propõe a elaboração de um PSP para a situação específica de pacientes com sistemas de EEP submetidos à exames de IRM no HMC, com base nas recomendações de segurança do fabricante e na revisão sistemática da literatura. De acordo com a base de dados consultada, um total de 26 artigos científicos foram considerados relevantes e permitiram identificar as possíveis fontes de risco de forma a evitá-las, colaborando com a conclusão satisfatória do PSP. Além de suprir a demanda local, o presente trabalho visou também promover a cultura de segurança do paciente e despertar a atenção para a necessidade de interposição de barreiras às diversas oportunidades de EAs que os setores de radiologia podem oferecer. A metodologia aqui proposta pode servir, ainda, de base para que outros centros de diagnóstico por imagem componham seus próprios PSPs. / In 2013, the National Program Patient Safety (PNSP) was implemented in Brazil through Resolution RDC 36, providing that the Brazilian health institutions must have a Patient Safety Plan (PSP) for situations that may lead to adverse events (AEs), which are unintentional injury or damage caused to the patient by the health care intervention and not by the primary disease. The PSP is a document with scientific basis that points to hazardous situations and describes strategies and actions defined by the health service for risk management in order to prevent and reduce AEs in all phases of patient care. Implantation of Deep Brain Stimulation (DBS) devices is considered a routine procedure at the Hospital Marcelino Champagnat (HMC), located in Curitiba – PR, and it consists in a practice widely used to improve symptoms and quality of life of patients with certain chronic neurological disorders.The reliability and accuracy of the final brain positioning of the leads, after the DBS implantation are of paramount importance to assure efficacy. Currently, post-operative Magnetic Resonance Imaging (MRI) is the gold standard for the documentation of the correct lead positioning. However, the interaction between the DBS system and the MRI radiofrequency field could represent an important source of adverse events (EAs) since it allows electric currents induction with potential to cause local thermal injuries on high resistance sites. The safety recommendations from the DBS system manufacturers for most of the already deployed systems are quite restrictive resulting in long examination times or low quality images, which compromises the practice in many centers. Thus, the present work proposes the development of a PSP based on the manufacturer's safety recommendations and a systematic review of the literature to the specific situation of patients with DBS systems undergoing MRI scans at the HMC. We found a total of 26 papers, that were considered relevant and allowed us to identify the potential sources of risk in order to avoid them, collaborating to the successful elaboration of the PSP. Besides supplying local demand, this work also aims to promote patient safety and draw attention to the need of interposing barriers in order to avoid significant AEs situations that a radiology department may be presented with. Moreover, the methodology proposed here can serve as a basis for other imaging centers to compose their own PSPs.
19

Estimulação transcraniana por corrente continua na fase aguda do episódio depressivo maior: uma meta-análise de dados individuais / Transcranial direct current stimulation for acute major depressive episodes: meta-analysis of individual patient data

Adriano Henrique de Matos Moffa 30 May 2016 (has links)
Introdução: A Estimulação Transcraniana por Corrente Contínua (ETCC) é uma intervenção não farmacológica com resultados discordantes quanto à sua eficácia para o tratamento do Episódio Depressivo Maior (EDM). Possivelmente devido a heterogeneidade dos estudos, as três meta-análises publicadas até agora sobre o assunto apontam para uma pequena vantagem a favor da técnica, dependendo da variável de desfecho analisada (melhora de depressão ou resposta). Todas essas meta-análises utilizaram dados agregados. Focamo-nos, no presente estudo, na realização de uma revisão sistemática da literatura e de uma meta-análise baseada em dados individuais de pacientes (MA-DIP) com Depressão Maior (DM) submetidos à ETCC na fase aguda. Este tipo de análise é mais preciso na avaliação da eficácia de uma intervenção e na obtenção dos preditores de respostas de tratamento, já que as características individuais de cada sujeito são consideradas ao invés das médias e frequências, como nas meta-análises de dados agregados. Objetivos: (1) avaliar a eficácia da ETCC na fase aguda da DM, (2) identificar preditores de resposta, remissão e melhora da depressão específicos e (3) avaliar a aceitabilidade da intervenção. Resultados: Os dados foram colecionados de 6 ensaios clínicos randomizados placebo controlados, totalizando 289 sujeitos. A ETCC ativa foi estatisticamente superior à estimulação simulada em relação à resposta (34% vs. 19%, respectivamente; RC=2,44, IC 95% = 1,38-4,32, NNT=7), remissão (23,1% vs. 12,7%, respectivamente; RC= 2,38, IC 95% = 1,22 - 4,64, NNT=9) e melhora da depressão (coeficiente = 0,35, IC 95% =0,12 0,57). Demonstrou-se que após ajustes para outros preditores e confundidores, depressão resistente a tratamento e doses mais altas de ETCC foram, respectivamente, inversa e diretamente associadas com a eficácia da ETCC. Conclusões: O tamanho de efeito do tratamento com ETCC foi comparável àqueles reportados, em outros estudos, para a Estimulação Magnética Transcraniana repetitiva (EMTr) e para o tratamento farmacológico (com antidepressivos tricíclicos e inibidores seletivos de recaptação de serotonina) na atenção primária para depressão. Os parâmetros mais importantes para otimização em ensaios clínicos futuros são a refratariedade da depressão e a dose da ETCC / Introduction: Transcranial direct current stimulation (tDCS) is a nonpharmacological intervention for depression. Randomised, sham-controlled clinical trials (RCTs) conducted hitherto have presented mixed results regarding its efficacy. Although recent meta-analyses suggest some efficacy when measuring depression symptoms using a continuous outcome, these meta-analyses were limited in their results as they used an aggregate data approach. We aimed therefore to perform an individual patient data (IPD) meta-analysis. In contrast to an aggregate data meta-analysis, an IPD approach uses the raw data of each participant within a study. IPD is more accurate in estimating the efficacy of an intervention since aggregate data meta-analyses present only summary estimates of efficacy. IPD meta-analysis is also superior to the aggregate data approach for obtaining predictors of treatment outcome, as the characteristics of each patient are assessed instead of the mean and frequency values obtained in the traditional aggregate data meta-analysis. Objectives (a) To provide precise estimates of tDCS efficacy based on continuous (depression improvement) and categorical (response and remission rates) outcomes, (b) to identify variables associated with tDCS efficacy and (c) to estimate the treatment acceptability. Results: Data were gathered from six randomised sham-controlled trials, enrolling 289 patients. Active tDCS was significantly superior to sham for response (34% v. 19%, respectively, odds ratio (OR) = 2.44, 95% CI 1.384.32, number needed to treat (NNT) = 7), remission (23.1% v. 12.7%, respectively, OR = 2.38, 95% CI 1.224.64, NNT = 9) and depression improvement ( coefficient 0.35, 95% CI 0.120.57). Mixed effects models showed that, after adjustment for other predictors and confounders, treatment-resistant depression and higher tDCS doses were, respectively, negatively and positively associated with tDCS efficacy. Conclusions: The effect size of tDCS treatment was comparable with those reported for repetitive transcranial magnetic stimulation (rTMS) and antidepressant drug treatment in primary care. The most important parameters for optimisation in future trials are depression refractoriness and tDCS dose

Page generated in 0.094 seconds