• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 87
  • 1
  • Tagged with
  • 89
  • 89
  • 89
  • 89
  • 56
  • 56
  • 54
  • 31
  • 22
  • 16
  • 16
  • 14
  • 14
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Modificação da superfície de sílica gel com grupos aromáticos para aplicação na pré-concentração de compostos fenólicos meio aquoso

Foschiera, Jose Luiz January 1999 (has links)
O trabalho aqui proposto conjuga estudos de química fina, com aplicação na área de química analítica ambiental. A proposta envolve a avaliação da possibilidade de utilização destes materiais como fase sólida para o desenvolvimento futuro de metodologia analítica para pré-concentração de analitos em nível de traços. Neste trabalho, a sílica gel com propriedades físicas bem definidas, foi primeiramente modificada com grupos 3-aminopropiltrimetoxisilanos e 3-cloropropiltrimetoxisilanos. Posteriormente, os grupos cloro e aminopropil ligados à superfície da sílica gel, foram reagidos através de reações de substituição com os seguintes grupos aromáticos: p-anisidina, anilina e benzilamina foram enxertados na sílica gel contendo grupos c1oropropil na superfície; 3-fenilc1oropropil foi enxertado na sílica gel contendo grupos aminopropil na superfície. A caracterização dos sorventes sintetizados foi realizada por análise no infravermelho, que confirmou a presença dos grupos aromáticos ligados à superfície da sílica gel. A estabilidade térmica foi determinada por análise termogravimétrica e no infravermelho, observando-se que todas as fases sólidas sintetizadas são termicamente estáveis até pelo menos 260°C. A determinação da quantidade de grupos aromáticos• enxertados na superfície da sílica gel foi realizada através de análise elementar (CHN), obtendo-se concentrações de pelo menos 0,30 mmol de grupos aromáticos ligados a superfície, para cada grama de sílica gel utilizada. F oi avaliada a capacidade de retenção dos adsorventes frente a compostos fenólicos em meio aquoso. Os compostos fenólicos utilizados como analíticos para o presente estudo foram: fenol, o-cresol, m-cresol, p-cresol, 2-etilfenol, 3-etilfenol e 4-etilfenol. Sendo que destes, alguns estão incluídos na lista de poluentes prioritários da Agência de Proteção Ambiental Americana, US-EPA e da Comunidade Européia, EC. A identificação e caracterização dos compostos fenólicos presentes como analitos no estudo realizado, foi conduzida via espectrometria de massas acoplada à gromatografia gasosa, GC-MS. A determinação quantitativa da eficiência dos adsorventes, na pré-concentração dos compostos fenólicos, foi realizada através de análise por cromatografia gasosa com detector de ionização de chama, GC-FID. Os valores de retenção dos compostos fenólicos acima citados, através do método de pré-concentração por extração em fase sólida utilizando as fases sintetizadas neste trabalho, foram bem superiores aos valores obtidos quando da utilização da sílica gel pura como fase estacionária. Nos estudos aqui realizados, pôde-se verificar que o aumento na densidade eletrônica do anel aromático produz um aumento na capacidade de adsorção dos analitos pela superfície. / This work deals with advanced surfaces and its application on environrnental chemistry. The purpose is the development of analytical methods for pre-concentration of analytes at trace leveIs Silica gel modified with 3-chloropropy1trimethoxysilane was grafted with the aromatic groups aniline, p-anisidine and benzylamine and silica gel modified with 3-aminopropyltrimetoxysilane was grafted with 3-phenyi1chloropropyl. The characterization of the synthesised adsorbents was carried out using infrared spectroscopy which confirmed the presence of aromatic groups on the surface. Thermal stability of surfaces was observed by thermogravimetric analysis and infrared spectroscopy. The surfaces are very stable up to 260°C. The quantitative analysis was carried out using CHN elemental analysis and aromatics groups on the surface showed a concentration greater than 0.30 mmol . gol. Evaluation of the retention capacity of phenolic compounds was carried out in aqueous medium. The compounds phenol, o-cresol, m-cresol, p-cresol, 2-ethylphenol, 3-ethylphenol, and 4-ethylphenol were studied by being main pollutants according to The United States Environmental Protection agency (US-EP A) and The European Community (EC). Gas chromatography coupled to mass spectrometry (GC-MS) was used for the identification and characterization of phenolic compounds. Quantitative analysis of phenolic compounds and the adsorbents performance in pre-concentration was determined by gas chromatography with flame ionisation detector (GC-FID). The sorption capacities of the modified silica are better than those of pure silica gel. The increase in electronic density of aromatics rings grafted on the silica gel surface causes na increase in the sorption capacity.
22

Aplicação da extração em fase sólida na pré-concentração de compostos fenólicos clorados em efluentes de branqueamento de celulose

Oliveira, Eniz Conceição January 1999 (has links)
O presente trabalho teve como objetivo o desenvolvimento de metodologia analítica na técnica de extração em fase sólida para a análise de compostos fenólicos clorados em efluentes aquosos oriundos do processo de branqueamento de celulose, de modo a comparar com a técnica clássica de extração líquido':'líquido. Primeiramente, foram utilizadas amostras de soluções padrão de compostos fenólicos clorados, a fim de verificar qual a melhor técnica de extração, extração líquido-líquido (LL) ou extração em fase sólida (SPE), utilizando cartuchos comerciais de fase C18 e de fase tC18. Foram realizados vários experimentos para o estabelecimento das melhores condições de extração para a SPE sendo os resultados comparados com o da extração LL. Os dados obtidos, revelaram que a extração em fase sólida utilizando cartucho com fase C18 demonstrou maior eficiência, sendo a mesma escolhida para análise das amostras dos efluentes de branqueamento de celulose da empresa Cambará Celulose S.A. A análise dos efluentes de branqueamento pela técnica SPE com cartucho comercial de fase C18 foi realizada com o auxílio das técnicas de cromatografia gasosa com detector de captura de elétrons e cromatografia gasosa acoplada a espectrômetro de massas. A identificação dos compostos se deu através da comparação dos tempos de retenção e dos espectros de massas com padrão dos respectivos compostos, sendo identificados os seguintes clorados: 3,5-diclorofenol, 2,4,6-triclorofenol, 4-clorocatecol, 4,5- dicloroguaiacol, 3,5-diclorocatecol, 6-clorovanilina, 4,5-diclorocatecol, 4,5,6- tricloroguaiacol, 5,6-diclorovanilina, 3,4,5,6-tetraclorocatecol, 3,4,5- triclorosiringol e 3,4,5,6-tetraclorocatecol, dos quais somente nove foram quantificados pela técnica da padronização interna. Também foram determinadas as toxicidades referentes ao pentaclorofenol e o Fator de Toxicidade Equivalente Total (TEF) para cada efluente estudado. Os valores obtidos, 0,110 mg.L-¹ para o primeiro efluente, 512 mg.L-¹ para o segundo e 103 mg.L-¹ para o terceiro efluente, estes valores foram superiores ao valor de LDso para o pentaclorofenol que é de 0,096 mg.L-¹, indicando um grau significativo de toxidez para os mesmos. / The present work aims the development of an analytical methodology for the solid phase extraction technique applied to the analysis of chlorinated phenolic compounds in aqueous effluents from the cellulose bleaching process by comparison with the classical liquid-liquid extraction technique. Firstly, samples of standard solutions of chlorinated phenolic compounds were employed in order to verify which extraction technique was the best; liquid-liquid extraction (LL) or solid phase extraction (SPE) using commercial cartridges of C18 phase and tC18 phase. Several experiments were performed for establishing the best SPE extraction conditions. The results were compared to those for the LL extraction. Results obtained showed better efficiency for the solid phase extraction with C18 phase cartridge being this extraction chosen for the analysis of samples from the cellulose bleaching effluents produced by Cambará Celulose S.A. The bleaching effluent analysis by SPE technique with C 18 phase cartridge was carried out by gas chromatography using electron capture detector and gas chromatography coupled to mass spectrometry. Compounds identification was made by comparing retention times and mass spectra with those of standards of the respective compounds. The following chlorinated compounds have been identified: 3,5-dichlorophenol, 3,4,6-trichlorophenol, 4- chlorocatechol, 4,5-dichloroguaiacol, 3,5-dichlorocatechol, 6-chlorovanillin, 4,5-dichlorocatechol, 4,5,6-trichloroguaiacol, 5,6-dichlorovanillin, 3,4,5,6- tetrachlorocatechol, 3,4,5-trichlorosyringol and 3,4,5,6-tetrachlorocatechol, from which nine have been quantified by internai standard technique. Toxicity relative to pentachlorophenol and the Total Equivalent Toxicity Factor (TEF) for each effluent were also determined. The obtained values; 0.110 mg.L-¹ for the first effluent and 512 mg.L-¹ and 103 mg.-¹L for the second and third effluents are bigger than the LDso for pentachlorophenol which is 0.096 mg.-¹L, pointing for a significative toxicity of the studied compounds.
23

Estudo de ácidos naftênicos em petróleo brasileiro: Métodos de extração e análise cromatográfica

Gruber, Liliane Dailei Almeida January 2009 (has links)
Os ácidos naftênicos (AN) são considerados os principais responsáveis pela corrosão durante a fase líquida do refino de petróleo e, como os óleos crus nacionais apresentam altos índices de acidez, medidos pelo índice TAN (do inglês total acid number), têm recebido especial atenção em recentes pesquisas sobre seu conteúdo e natureza. Contudo, não existe um método de extração validado que permita extrair os AN do petróleo em quantidade suficiente para a caracterização e identificação estrutural. Neste trabalho foram testados vários métodos de extração dos AN (cromatografia líquida de alta eficiência em escala preparativa, cromatografia líquida em coluna aberta e extração em fase sólida) para duas frações de petróleo brasileiro com elevada acidez. Foram avaliadas as diferentes fases estacionárias e o melhor procedimento foi a extração em fase sólida com fase SAX. Os extratos e uma amostra técnica de AN foram analisados por cromatografia gasosa monodimensional e bidimensional abrangente com detectores de ionização por chama e espectrometria de massas. Para a mistura técnica de AN também se fez uso de técnicas espectroscópicas (ressonância magnética nuclear e infravermelho) que se mostraram eficientes para a sua caracterização, além das técnicas cromatográficas. Os resultados indicaram a presença majoritária de ácidos carboxílicos acíclicos com até C e de alguns AN monocíclicos com até 18 átomos de carbono. / Naphthenic acids (NA) are considered primarily responsible for corrosion in the liquid phase of the petroleum refining, and as national crude oils presents high levels of acidity, measured by the TAN (Total Acid Number), they have receiving special attention in recent research about their content and nature. However, there is no validated extraction method that allows extracting the NA oil in sufficient quantity for characterization and structural identification. Several methods for extraction of NA were tested in this study (HPLC in preparative scale, open column liquid chromatograhpy and solid phase extraction) for two fractions of Brazilian oil with high acidity. Different stationary phases were evaluated and the best procedure is the solid phase extraction with SAX phase. The extracts and a technique NA sample were analyzed by gas chromatography mono dimensional and comprehensive twodimensional with detector flame ionization and mass spectrometry. For technical mixture of NA it was also carried out spectroscopic techniques (nuclear magnetic resonance and infrared) that have proven to be successful for this characterization, in addition to chromatographic techniques. The results indicated the predominant presence of carboxylic acids up to C20 alcohols and some NA monocyclic up to 18 carbon atoms.
24

Modificação da superfície de sílica gel com grupos aromáticos para aplicação na pré-concentração de compostos fenólicos meio aquoso

Foschiera, Jose Luiz January 1999 (has links)
O trabalho aqui proposto conjuga estudos de química fina, com aplicação na área de química analítica ambiental. A proposta envolve a avaliação da possibilidade de utilização destes materiais como fase sólida para o desenvolvimento futuro de metodologia analítica para pré-concentração de analitos em nível de traços. Neste trabalho, a sílica gel com propriedades físicas bem definidas, foi primeiramente modificada com grupos 3-aminopropiltrimetoxisilanos e 3-cloropropiltrimetoxisilanos. Posteriormente, os grupos cloro e aminopropil ligados à superfície da sílica gel, foram reagidos através de reações de substituição com os seguintes grupos aromáticos: p-anisidina, anilina e benzilamina foram enxertados na sílica gel contendo grupos c1oropropil na superfície; 3-fenilc1oropropil foi enxertado na sílica gel contendo grupos aminopropil na superfície. A caracterização dos sorventes sintetizados foi realizada por análise no infravermelho, que confirmou a presença dos grupos aromáticos ligados à superfície da sílica gel. A estabilidade térmica foi determinada por análise termogravimétrica e no infravermelho, observando-se que todas as fases sólidas sintetizadas são termicamente estáveis até pelo menos 260°C. A determinação da quantidade de grupos aromáticos• enxertados na superfície da sílica gel foi realizada através de análise elementar (CHN), obtendo-se concentrações de pelo menos 0,30 mmol de grupos aromáticos ligados a superfície, para cada grama de sílica gel utilizada. F oi avaliada a capacidade de retenção dos adsorventes frente a compostos fenólicos em meio aquoso. Os compostos fenólicos utilizados como analíticos para o presente estudo foram: fenol, o-cresol, m-cresol, p-cresol, 2-etilfenol, 3-etilfenol e 4-etilfenol. Sendo que destes, alguns estão incluídos na lista de poluentes prioritários da Agência de Proteção Ambiental Americana, US-EPA e da Comunidade Européia, EC. A identificação e caracterização dos compostos fenólicos presentes como analitos no estudo realizado, foi conduzida via espectrometria de massas acoplada à gromatografia gasosa, GC-MS. A determinação quantitativa da eficiência dos adsorventes, na pré-concentração dos compostos fenólicos, foi realizada através de análise por cromatografia gasosa com detector de ionização de chama, GC-FID. Os valores de retenção dos compostos fenólicos acima citados, através do método de pré-concentração por extração em fase sólida utilizando as fases sintetizadas neste trabalho, foram bem superiores aos valores obtidos quando da utilização da sílica gel pura como fase estacionária. Nos estudos aqui realizados, pôde-se verificar que o aumento na densidade eletrônica do anel aromático produz um aumento na capacidade de adsorção dos analitos pela superfície. / This work deals with advanced surfaces and its application on environrnental chemistry. The purpose is the development of analytical methods for pre-concentration of analytes at trace leveIs Silica gel modified with 3-chloropropy1trimethoxysilane was grafted with the aromatic groups aniline, p-anisidine and benzylamine and silica gel modified with 3-aminopropyltrimetoxysilane was grafted with 3-phenyi1chloropropyl. The characterization of the synthesised adsorbents was carried out using infrared spectroscopy which confirmed the presence of aromatic groups on the surface. Thermal stability of surfaces was observed by thermogravimetric analysis and infrared spectroscopy. The surfaces are very stable up to 260°C. The quantitative analysis was carried out using CHN elemental analysis and aromatics groups on the surface showed a concentration greater than 0.30 mmol . gol. Evaluation of the retention capacity of phenolic compounds was carried out in aqueous medium. The compounds phenol, o-cresol, m-cresol, p-cresol, 2-ethylphenol, 3-ethylphenol, and 4-ethylphenol were studied by being main pollutants according to The United States Environmental Protection agency (US-EP A) and The European Community (EC). Gas chromatography coupled to mass spectrometry (GC-MS) was used for the identification and characterization of phenolic compounds. Quantitative analysis of phenolic compounds and the adsorbents performance in pre-concentration was determined by gas chromatography with flame ionisation detector (GC-FID). The sorption capacities of the modified silica are better than those of pure silica gel. The increase in electronic density of aromatics rings grafted on the silica gel surface causes na increase in the sorption capacity.
25

Aplicação da extração em fase sólida na pré-concentração de compostos fenólicos clorados em efluentes de branqueamento de celulose

Oliveira, Eniz Conceição January 1999 (has links)
O presente trabalho teve como objetivo o desenvolvimento de metodologia analítica na técnica de extração em fase sólida para a análise de compostos fenólicos clorados em efluentes aquosos oriundos do processo de branqueamento de celulose, de modo a comparar com a técnica clássica de extração líquido':'líquido. Primeiramente, foram utilizadas amostras de soluções padrão de compostos fenólicos clorados, a fim de verificar qual a melhor técnica de extração, extração líquido-líquido (LL) ou extração em fase sólida (SPE), utilizando cartuchos comerciais de fase C18 e de fase tC18. Foram realizados vários experimentos para o estabelecimento das melhores condições de extração para a SPE sendo os resultados comparados com o da extração LL. Os dados obtidos, revelaram que a extração em fase sólida utilizando cartucho com fase C18 demonstrou maior eficiência, sendo a mesma escolhida para análise das amostras dos efluentes de branqueamento de celulose da empresa Cambará Celulose S.A. A análise dos efluentes de branqueamento pela técnica SPE com cartucho comercial de fase C18 foi realizada com o auxílio das técnicas de cromatografia gasosa com detector de captura de elétrons e cromatografia gasosa acoplada a espectrômetro de massas. A identificação dos compostos se deu através da comparação dos tempos de retenção e dos espectros de massas com padrão dos respectivos compostos, sendo identificados os seguintes clorados: 3,5-diclorofenol, 2,4,6-triclorofenol, 4-clorocatecol, 4,5- dicloroguaiacol, 3,5-diclorocatecol, 6-clorovanilina, 4,5-diclorocatecol, 4,5,6- tricloroguaiacol, 5,6-diclorovanilina, 3,4,5,6-tetraclorocatecol, 3,4,5- triclorosiringol e 3,4,5,6-tetraclorocatecol, dos quais somente nove foram quantificados pela técnica da padronização interna. Também foram determinadas as toxicidades referentes ao pentaclorofenol e o Fator de Toxicidade Equivalente Total (TEF) para cada efluente estudado. Os valores obtidos, 0,110 mg.L-¹ para o primeiro efluente, 512 mg.L-¹ para o segundo e 103 mg.L-¹ para o terceiro efluente, estes valores foram superiores ao valor de LDso para o pentaclorofenol que é de 0,096 mg.L-¹, indicando um grau significativo de toxidez para os mesmos. / The present work aims the development of an analytical methodology for the solid phase extraction technique applied to the analysis of chlorinated phenolic compounds in aqueous effluents from the cellulose bleaching process by comparison with the classical liquid-liquid extraction technique. Firstly, samples of standard solutions of chlorinated phenolic compounds were employed in order to verify which extraction technique was the best; liquid-liquid extraction (LL) or solid phase extraction (SPE) using commercial cartridges of C18 phase and tC18 phase. Several experiments were performed for establishing the best SPE extraction conditions. The results were compared to those for the LL extraction. Results obtained showed better efficiency for the solid phase extraction with C18 phase cartridge being this extraction chosen for the analysis of samples from the cellulose bleaching effluents produced by Cambará Celulose S.A. The bleaching effluent analysis by SPE technique with C 18 phase cartridge was carried out by gas chromatography using electron capture detector and gas chromatography coupled to mass spectrometry. Compounds identification was made by comparing retention times and mass spectra with those of standards of the respective compounds. The following chlorinated compounds have been identified: 3,5-dichlorophenol, 3,4,6-trichlorophenol, 4- chlorocatechol, 4,5-dichloroguaiacol, 3,5-dichlorocatechol, 6-chlorovanillin, 4,5-dichlorocatechol, 4,5,6-trichloroguaiacol, 5,6-dichlorovanillin, 3,4,5,6- tetrachlorocatechol, 3,4,5-trichlorosyringol and 3,4,5,6-tetrachlorocatechol, from which nine have been quantified by internai standard technique. Toxicity relative to pentachlorophenol and the Total Equivalent Toxicity Factor (TEF) for each effluent were also determined. The obtained values; 0.110 mg.L-¹ for the first effluent and 512 mg.L-¹ and 103 mg.-¹L for the second and third effluents are bigger than the LDso for pentachlorophenol which is 0.096 mg.-¹L, pointing for a significative toxicity of the studied compounds.
26

Pré-concentração e Determinação de Íons pb(ii) Empregando Sílica Modificada com 3,6-ditia-1,8-octanodiol por Mcfia-faas em Amostras de Leite

SILVA, Paulo Alberto Bezerra da Silva 31 January 2012 (has links)
Submitted by Etelvina Domingos (etelvina.domingos@ufpe.br) on 2015-03-11T18:35:14Z No. of bitstreams: 2 DISSERTAÇÃO Paulo Alberto Bezerra da Silva.pdf: 2114412 bytes, checksum: e5bc7b1de39e4187cc8c289d2ab2adc1 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-11T18:35:14Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Paulo Alberto Bezerra da Silva.pdf: 2114412 bytes, checksum: e5bc7b1de39e4187cc8c289d2ab2adc1 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012 / CNPq / O objetivo deste trabalho foi a determinação de chumbo em amostras de leite por espectrometria de absorção atômica por chama (FAAS). Para tanto foi desenvolvido um sistema em fluxo multicomutado para a pré-concentração de Pb2+ acoplado ao FAAS utilizando um material de sílica funcionalizada como fase estacionária no processo de extração em fase sólida. O sistema em fluxo proposto consiste de uma bomba peristáltica para a propulsão dos fluidos e seis válvulas solenóide de três vias para o gerenciamento das soluções. Esses dispositivos foram controlados por um computador, empregando um programa desenvolvido em LabVIEW® interfaceada por um sistema eletrônico baseado no circuito integrado (CI) ULN2803A acoplado a porta paralela LPT1 do computador. A síntese da sílica modificada foi realizada pelo processo sol-gel e para sua funcionalização com 3,6-ditia-1,8-octanodiol utilizou-se o métoxido de sódio como catalisador. As análises dos espectros de infravermelho e das curvas termogravimétricas evidenciaram a formação da sílica modificada. A coluna foi preenchida com 100mg do material sintetizado, o qual apresentou boa regeneração, usada em média por 50 pré-concentrações. Nos estudos de otimização os melhores resultados foram pH 9,0, o eluente foi o HNO3 0,5 mol L-1 com volume de 1,4 mL e vazão de 1,4 mL min-1. Para a amostra, a vazão foi de 2,20 mL min-1 e verificou-se que quanto maior o volume e menor a vazão, maior será o fator de enriquecimento (F.E.), porém os melhores valores não foram escolhidos devido ao longo tempo de pré-concentração. Assim, foi estabelecido o volume de amostra entre 8,0 e 52,8 mL dependendo da faixa de concentração que se deseja trabalhar e do F.E. que é almejado. Essas possibilidades estão diretamente relacionadas com a frequência analítica que variou-se de 2 a 6 determinações h-1. As amostras de leite tipo A, foram preparadas através da digestão ácida por aquecimento em micro-ondas. A precisão do sistema foi estimada através de 30 determinações, apresentando desvio padrão relativo de 3,8%, a exatidão foi satisfatória e atestada através da análise de recuperação. O sistema proposto possibilitou um aumento de 100 vezes no limite de detecção (de 100 para 1,0 μg L-1) e 20 vezes no limite de quantificação (de 100 para 5,0 μg L-1) para os íons Pb2+. Este fato nos deu a possibilidade de detectar contaminações a níveis abaixo do permitido em amostras de leite. O sistema em fluxo possibilitou à automatização da extração e detecção, diminuindo assim a interferência do analista, além de assegurar a repetibilidade dos volumes injetados e coletados, proporcionando assim uma boa precisão. Com isso, o sistema proposto apresentou robustez e eficiência para a pré-concentração e determinação por FAAS de íons Pb2+ em amostras de leite.
27

Avaliação da aplicação de potencial elétrico em extração em fase sólida na determinação de sulfonamidas e fluoroquinolonas em ovos / Evaluation of the application of electric potential in solid phase extraction for the determination of sulfonamides and fluoroquinolones in eggs

Ribeiro, Cyntia Cabral, 1977- 26 August 2018 (has links)
Orientadores: Felix Guillermo Reyes Reyes, Susanne Rath / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-26T09:04:09Z (GMT). No. of bitstreams: 1 Ribeiro_CyntiaCabral_D.pdf: 2553496 bytes, checksum: c2200295b5cb6899de7fa33b75518899 (MD5) Previous issue date: 2014 / Resumo: Sulfonamidas e fluoroquinolonas são fármacos veterinários amplamente utilizados na produção aviária para prevenção e tratamento de doenças e, quando não respeitadas as boas práticas veterinárias, resíduos desses fármacos podem ser encontrados acima dos limites máximos de resíduos podendo representar risco à saúde dos consumidores. Sendo o ovo uma matriz biológica complexa, quantidades significativas de interferentes podem prejudicar a determinação dos analitos de interesse por cromatografia líquida, especialmente resíduos de fármacos veterinários, que se encontram em níveis na ordem de ng g-1. Entre as diversas técnicas de preparo de amostras capazes de eliminar interferentes e concentrar o analito de interesse, a extração em fase sólida (SPE) se destaca pela sua eficiência, robustez, seletividade e baixo consumo de solventes. Ainda assim, devido à complexidade da matriz e a baixa concentração dos analitos, o estabelecimento de métodos de preparo de amostras com seletividade na remoção de interferentes e eficiência de extração adequados ainda é um desafio na análise de resíduos. Desta forma, afim de se contornar as limitações da SPE convencional, esta tese teve como objetivo avaliar a aplicação de potencial elétrico em SPE (E-SPE) para a determinação de resíduos de sulfonamidas e fluoroquinolonas em ovos por cromatografia líquida de alta (HPLC) e ultra eficiência (UHPLC) associada à detectores por arranjo de fotodiodos (DAD), fluorescência (FLD) ou espectrômetro de massas sequencial (MS/MS). Os parâmetros de E-SPE foram avaliados de forma a obter a melhor condição no preparo de amostras e o método para a determinação de resíduos de sulfonamidas e fluoroquinolonas em ovos por E-SPE UHPLC-MS/MS foi avaliado em relação a linearidade, precisão, exatidão, além dos efeitos de supressão ou incremento de sinal analítico (efeito matriz) / Abstract: Sulfonamides and fluoroquinolones are veterinary drugs widely used in the poultry production for the prevention and treatment of diseases and, when good veterinary practices are not observed, residues of these drugs can be found above the maximum residue limit and may represent a risk to the consumers health. Since egg is a complex biological matrix, significant amounts of interferents can hinder the determination of analytes by liquid chromatography, particularly residues of veterinary drugs, which are at levels in the order of ng g-1. Among the various sample preparation techniques capable to eliminate interferences and concentrate the analyte of interest, the solid phase extraction (SPE) stands out for its efficiency, robustness, selectivity and low solvent consumption. Nevertheless, due to the complexity of the matrix and the low concentration of the analytes, the establishment of sample preparation methods with selectivity in removing interferents and appropriate extraction efficiency is still a challenge in residue analysis. Thus, in order to overcome the limitations of conventional SPE, this thesis aimed to evaluate the application of electrical potential in SPE (E-SPE) for the determination of sulfonamides and fluoroquinolones residues in eggs by high efficient (HPLC) and ultra efficient (UHPLC) performance liquid chromatography associated with a photodiode array (DAD), fluorescence (FLD) or sequential mass spectrometer (MS/MS) detectors. The E-SPE parameters were evaluated to obtain the best condition for sample preparation and the method for the determination of sulfonamides and fluoroquinolones residues in eggs by E-SPE UHPLC-MS/MS was evaluated for linearity, precision, accuracy, in addition to the effects of suppression or increase of the analytical signal (matrix effect) / Doutorado / Ciência de Alimentos / Doutora em Ciência de Alimentos
28

Preparação, caracterização e aplicação de sorvente C8 imobilizado termicamente sobre sílica zirconizada para extração em fase sólida / Preparation, characterization and application of thermally immobilized C8 onto zirconized silica as sorbent for solid-phase extraction

Magueta, Renata da Costa, 1984- 06 July 2013 (has links)
Orientador: Isabel Cristina Sales Fontes Jardim / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T21:45:28Z (GMT). No. of bitstreams: 1 Magueta_RenatadaCosta_M.pdf: 9269521 bytes, checksum: ce3c0368312fe2614e36d33195d8da7b (MD5) Previous issue date: 2013 / Resumo: Um novo sorvente para extração em fase sólida foi preparado utilizando a imobilização térmica do polímero poli(metiloctilsiloxano) sobre sílica zirconizada. Foram estudadas as etapas de preparo do sorvente, avaliando-se a quantidade de polímero, a temperatura e o tempo de imobilização e a extração do excesso de polímero não imobilizado. Também se determinou o volume de breakthrough e a eficiência de extração dos cartuchos preparados. Para avaliação da eficiência de extração dos sorventes, foram utilizadas amostras de água fortificadas com uma mistura dos agrotóxicos carbendazim, imidacloprido, acetamiprido, cimoxanil, carbofuram, carbaril, metiocarbe, tebuconazol, difenoconazol, pirimifós-metílico e piriproxifem. Os resultados de cada estudo realizado foram comparados com os obtidos para o sorvente preparado sobre sílica não modificada e foram consideradas adequadas as eficiências de extração entre 70 e 120%, com coeficiente de variação de até 20%. Com a sílica zirconizada, os melhores resultados foram obtidos com 50% de polímero sobre o suporte, imobilização a 120 °C por 4 horas e extração do excesso de polímero utilizando n-hexano, numa proporção de 36 mL de solvente para cada 1 g de material, a temperatura de 50 °C e vazão de 0,6 mL/min. A caracterização físico-química dos materiais mostrou que houve incorporação satisfatória do zircônio ao suporte de sílica no processo de metalização e o polímero encontra-se fisicamente sorvido e quimicamente ligado ao suporte. O estudo do volume de breakthrough dos cartuchos e a avaliação do desempenho do sorvente frente a variações de pH mostraram que a presença de átomos de zircônio na superfície do suporte aumenta a acidez dos grupos silanóis residuais, de modo que estes sítios interagem fortemente com os analitos básicos em pH elevado. Pôde-se observar que as eficiências de extração dos agrotóxicos também variam com a polaridade dos compostos, sendo que, o mecanismo de retenção é complexo, alternando entre interações hidrofóbicas e eletrostáticas. A aplicação do sorvente zirconizado na extração de agrotóxicos em amostras de suco de tomate mostrou que o mesmo apresenta potencial para ser empregado na extração em fase sólida de multirresíduos com características diversas de matrizes complexas / Abstract: A new sorbent for solid-phase extraction was prepared using thermal immobilization of the polymer poly(methyloctylsiloxane) onto a zirconized silica support. The steps of the preparation were studied evaluating the polymer loading, the temperature and time of immobilization and the extraction of the excess non-immobilized polymer as well as the cartridge¿s breakthrough volume and extraction efficiency. To evaluate the cartridge¿s extraction efficiency water samples fortified with a mixture of the pesticides carbendazin, imidacloprid, acetamiprid, cymoxanil, carbofuran, carbaryl, methiocarb, tebuconazole, difenoconazole, pirimiphos-methyl and pyriproxyfen were used. The results of each step were compared with those from the sorbent prepared with unmodified silica and adequate extraction efficiencies were considered as being between 70 and 120% with variation coefficients under 20%. With zirconized silica the best results were achieved with 50% polymer loading onto the support, immobilization at 120 °C for 4 hours and extraction of the excess non-immobilized polymer using n-hexane, in the proportion of 36 mL of solvent for 1 g of material, at 50 °C and at a 0.6 mL/min flow rate. The physical-chemical characterization of the materials showed that the incorporation of zirconium onto the silica support in the metalization process was satisfactory and the polymer is physically sorbed and chemically attached to the support. The studies concerning the breakthrough volume and the evaluation of the cartridge¿s performance over pH variations showed that the presence of the zirconium on the support¿s surface increases the acidity of the residual silanol so that these sites interact strongly with basic analytes at high pH. It was also possible to observe that the extraction efficiencies vary with the polarity of the compounds. The retention mechanism is complex, mixing hydrophobic and electrostatic interactions. The application of the zirconized sorbent in the extraction of pesticides from tomato juice samples showed that the sorbent has the potential to be used for multiresidue solid-phase extraction of complex matrices having a wide range of characteristics / Mestrado / Quimica Analitica / Mestra em Química
29

Análise de dietil tiofosfato e dietil ditiofosfato urinários empregando MISPE E Gc-Ms e estudo das correlações desses metabólitos com colinesterases sanguíneas e frequência de micronúcleos em ratos expostos a dissulfoton

SANTOS, Mariane Gonçalves 14 February 2012 (has links)
Um método analítico constituído por extração em fase sólida molecularmente impressa (MISPE) e cromatografia gasosa acoplada à espectrometria de massas (GC-MS) foi desenvolvido para análise de metabólitos dialquil fosfatos (dietil tiosfato - DETP e dietil ditiosfato - DEDTP) em amostras de urina. Um polímero de impressão molecular (MIP) foi sintetizado utilizando-se 4-vinilpiridina como monômero funcional e etileno glicol dimetacrilato como reagente de ligação cruzada. A etapa de condicionamento foi realizada da seguinte forma: 3 mL de acetonitrila, 3 mL de tampão fosfato dibásico 0,1 mol L-1, pH 11,0 e 2 mL de água foram percolados por um cartucho de polipropileno contendo o MIP. A etapa de extração foi executada utilizando 1,0 mL de amostra de urina com pH previamente ajustado para 3,0. Finalmente, os analitos foram eluídos com 3 mL de acetonitrila e derivatizados com uma solução de  2,3,4,5,6-brometo de  pentafluorobenzil a 3% em acetonitrila, a temperatura ambiente durante 1h. A amostra foi analisada por GC-MS. Curvas de calibração analítica para DETP e DEDTP foram construídas utilizando-se uma mistura de urina de diferentes indivíduos voluntários e em seis níveis de concentração. O método foi linear na faixa de  10-500 µg L-1, com r = 0,99 e limite de detecção de 3,0 µg L-1, para ambos os analitos. A precisão intra-dias e inter-dias foram avaliadas com base na porcentagem de desvio padrão relativo (%RSD) e todos os resultados foram inferiores a 15% para ambos os analitos. O método foi preciso, exato, com boa recuperação e robustez. Posteriormente o método foi utilizado para determinar as concentrações de DETP e DEDTP em amostras de urina de ratos expostos a dissulfoton. Além da concentração de dialquil fosfatos, foram determinadas a atividade de colinesterase sanguínea e a incidência de micronúcleos em eritrócitos policromáticos destes mesmos animais, a fim de se estabelecer uma relação entre a dose de exposição ao dissulfon e os parâmetros avaliados. Observou-se que a atividade de colinesterase plasmática não reflete muito bem a correlação entre a dose de exposição e efeito, ao contrário da colinesterase eritrocitária. A concentração de dialquil fosfatos refletiu uma boa correlação com a dose de exposição. Através da frequência de micronúcleos em eritrócitos policromáticos, foi possível observar que, a semelhança de outros praguicidas organofosforados (OF), o dissulfoton é capaz de causar mutagenicidade. / An analytical method constituted by molecularly imprinted solid phase extraction (MISPE) and gas chromatography mass spectrometry (GC-MS) was developed for analyses of benzene metabolites (diethyl thiophosphate - DETP and diethyl dithiophosphate - DEDTP) in human urine samples. A molecularly imprinted polymer (MIP) for DETP was synthesized using 4-vinylpiridine as functional monomer and ethylene glycol dimethacrylate as cross linker. The conditioning step of the MISPE was processed flowing though the MIP cartridge 3 mL of acetonitrile, 3 mL of dibasic phosphate buffer 0.1 mol L−1 pH 11 and 2 mL of water. The extraction step was executed using 1.0 mL of urine sample with pH previously adjusted to 3.0. Finally, the analytes were eluted with 3 mL of acetonitrile and derivatized with 2,3,4,5,6-pentafluorobenzyl bromide 3% at room temperature during 1h. The sample was analyzed by GC-MS. Analytical calibration curves for DETP and DEDTP were constructed using a pool of urine sample and for six levels of concentration. The method was linear from 10 to 500 μg L−1, with r = 0.99 and limit of detection of 3.0 μg L−1, for both analytes. The within-day and between-day precisions were evaluated (as percentage of RSD) and all results were < 15% for both analytes. The method was accurate, with good recovery and robustness. Later this method was used to determine the concentrations of DETP and DEDTP in urine samples of rats exposed to disulfoton. Besides the concentration of dialkyl phosphates, it was determined blood cholinesterase activity and the incidence of micronucleated polychromatic erythrocytes in the same animals, in order to establish a relationship between the dose of exposure and the evaluated parameters. It was observed that the plasma cholinesterase activity did not reflect very well the correlation between exposure dose and effect, unlike the erythrocyte cholinesterases. The concentration of dialkyl phosphates gave a good correlation with exposure dose. By the frequency of micronucleated polychro-matic erythrocytes was possible to observe that, similarly to other organophosphates pesticides (OPs), disulfoton can causes mutagenicity. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
30

Análise toxicológica de antidepressivos em sangue total por cromatografia em fase gasosa com detector de nitrogênio e fósforo / Toxicology analysis of antidepressants in whole blood with gas chromatography and nitrogen-phosphorus detection

Paula, Daniela Mendes Louzada de 26 March 2007 (has links)
Um método cromatográfico foi desenvolvido para determinação dos antidepressivos mais prescritos no Brasil e seus produtos de biotransfomação (amitriptilina, imipramina, clomipramina, desmetilclomipramina, desipramina, nortriptilina, fluoxetina, norfluoxetina e sertralina) em sangue total por cromatografia em fase gasosa com detector de nitrogênio e fósforo. A extração em fase sólida (EFS) com o cartucho abselutTM NEXUS foi empregada de forma inovadora. O procedimento de extração consistiu na diluição de 0,5mL de sangue total em tampão (pH 9,5), aplicação da amostra no cartucho, remoção de interferentes usando tampão (pH 9,5) e eluição dos analitos com diclorometano/ isopropanol (17/3 v/v); a etidocaína foi adotada como padrão interno. Os limites de detecção (LD) e quantificação (LIQ) encontrados foram de 0,1mg/L a 0,4mg/L e de 0,4mg/L a 1,6mg/L, respectivamente. O método foi preciso, específico e linear na faixa de concentração estudada (do LIQ até 12mg/L). A recuperação média de todos os analitos foi 65,5%. O método foi aplicado em amostras de âmbito forense e de emergência clínica. / A gas chromatographic method was developed to determine antidepressants most prescribed in Brazil and their metabolites (amitriptyline, imipramine, clomipramine, desmethylclomipramine, desipramine, nortriptyline, fluoxetine, norfluoxetine, and sertralina) in whole blood, using solid phase extraction and gas chromatography with nitrogen-phosphorus detection. The solid-phase extraction (SPE) with abselutTM NEXUS was applied in an innovative manner. The extraction procedure consists of the dilution of 0.5mL of whole blood in buffer (pH 9.5), application of the sample in the cartridge, washing with buffer (pH 9.5) and elution of the analytes with dichloromethane/isopropanol (17/3, v/v). The limit of detection (LOD) and quantification (LLOQ) were from 0.1mg/L to 0.4mg/L and from 0.4mg/L to 1.6mg/L, respectively. Etidocaine was used as internal standard. The method was precise, specific and linear in the studied concentration (range from LLOQ to 12mg/L). The average recovery of all analytes was 65,5%. Forensic and clinical emergency samples were submitted to the validated method.

Page generated in 0.1137 seconds