• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 6
  • 5
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 95
  • 25
  • 18
  • 16
  • 16
  • 15
  • 15
  • 13
  • 13
  • 12
  • 10
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Desenvolvimento e avaliação de células para sistema espectroeletroquímico em fluxo / Development and evaluation of cells for flow spectroelectrochemical system

Daniel, Daniela 13 September 2000 (has links)
O presente trabalho versa sobre o desenvolvimento e a avaliação de três novas células espectroeletroquímicas para medidas de absorção na região do ultravioleta e visível, compatíveis com operação em fluxo, inclusive a técnica de FIA (Flow Injection Analysis). Características inerentes ao primeiro protótipo construído, tais como, geometria tubular, operação em fluxo ascendente e em condições de convecção forçada por vibração, separador ionomérico entre os eletrodos e detecção espectrofotométrica ex situ, permitiram a realização de estudos espectroeletroquímicos mesmo sob a decomposição paralela do solvente com intenso desprendimento de gases no eletrodo de trabalho. O desenvolvimento conjunto de eficiente dispositivo para remoção de bolhas possibilitou a obtenção de excelentes resultados espectrofotométricos. Abriu-se caminho para o estudo espectroeletroquímico de processos situados em regiões de potencial em que ocorre concomitante decomposição do solvente. Igualmente apropriado para a realização de estudos espectroeletroquímicos sob formação de gases, o segundo protótipo é de construção bastante semelhante ao primeiro, porém a elevada relação área do eletrodo de trabalho/volume de solução, conseguida principalmente pelo preenchimento da célula com fibras de carbono, foi capaz de promover eficiente conversão eletroquímica permitindo trabalho em condição de operação semi-coulométrica e conferindo à célula sensibilidade mais elevada que a do primeiro protótipo. O terceiro protótipo é do tipo camada delgada com caminho óptico longo, de aplicação restrita, pois, a regiões de potencial em que não há formação de gases. Características vantajosas frente às alternativas descritas na literatura são: uso de eletrodos de ouro planos (aproveitados de CDs regraváveis) de baixo custo e fácil construção, adaptação direta a cubatas convencionais de 1 cm de caminho óptico. Parâmetros experimentais como: potencial aplicado, concentração, vazão e volume injetado, foram investigados e avaliados com a finalidade de estabelecer as melhores condições de trabalho e funcionamento dos protótipos construídos visando posterior aplicação. / The present work discusses about the development and the evaluation of three new spectroelectrochemical cells for the UV-vis region, well suited for flow operation, including FIA (Flow Injection Analysis). Tubular geometry of the ionomeric separator of the electrode compartments, operation under ascending flow with convection increased by vibration and ex situ spectrophotometric detection after passage through an efficient debubbler granted excellent spectrophotometric results to the first prototype, even under intense gas evolution at the working electrode. This feature extends the spectroelectrochemical study to processes at extreme potential ranges. Equally appropriate for spectroelectrochemical studies under gas evolution, the second prototype presents geometry similar to the first one. However, filling of the tubular working electrode compartment with carbon fibers rendered higher ratio of electrode area/solution volume, promoting a more efficient electrochemical conversion, allowing semi-coulometric operation, and thus augmenting the sensitivity of the absorbance measurements. The third prototype is of the thin layer, long optical path type. Although not suitable for work under gas evolution, advantages of this cell in comparison with those described in the literature are: use of inexpensive flat gold electrodes, obtained from Au recordable CDs, installation in conventional cuvettes with an optical path of 1 cm, simple construction, perfect flow operation. Experimental parameters such as applied potential, analyte concentration flow rate and injected volume were inspected and analyzed for all assembled cells in a way that the best working conditions could be achieved.
32

DDesenvolvimento de eletrodos modificados e métodos analíticos / Development of modified electrodes and analytical methods

Azevedo, Carla Maria Nunes 16 April 1999 (has links)
Neste trabalho foram desenvolvidos eletrodos modificados e procedimentos para a sua utilização na determinação de diversas espécies químicas de interesse analítico, dentre as quais sulfito, ácido ascórbico, nitrito, dopamina, NADH e peróxido de hidrogênio. Foram realizados estudos envolvendo eletrodos de carbono vítreo modificados com filmes contendo uma única metaloporfirina tetrarrutenada (catiônica) e aplicações analíticas destes sensores associando-os à análise por injeção em fluxo (FIA). Estes eletrodos apresentaram efeitos catalíticos sobre a oxidação de vários analitos, intensificando o sinal de corrente e deslocando seus picos de oxidação para a região de oxidação dos átomos de Ru(II) à Ru(III), sítios ativos das porfirinas. Contudo, para a obtenção de sensores estáveis, foi necessária a utilização de uma elevada concentração do contra-íon trifluorometanossulfonato em solução, prevenindo a gradual solubilização do filme modificador. Tal dificuldade foi contornada recobrindo-se os eletrodos com filmes laminares contendo simultaneamente pares de porfirinas catiônicas e aniônicas. Estes sensores apresentaram ação catalítica igual aos eletrodos recobertos por uma única porfirina, uma vez que os sítios ativos continuaram sendo os átomos de rutênio. Esta nova geração de eletrodos modificados exibiu excelente desempenho tanto em análises de amostras sintéticas, quanto de amostras reais (sulfitos em vinhos e ácido ascórbico em sucos e medicamentos). Os sensores modificados com metaloporfirinas apresentaram excelente sensibilidade (limites de detecção entre 10-8 e 10-6 mol L-1) e minimizaram os efeitos de envenenamento da superfície, além de serem de fácil preparo. No presente trabalho também foram realizados estudos preliminares envolvendo eletrodos de pasta de carbono dopados com o óxido misto de NdNiO3. Estes destacaram-se, principalmente, por antecipar a oxidação de peróxido de hidrogênio para 0,00 V em meio alcalino. Análises utilizando o sistema BIA (Batch Injection Analysis) possibilitaram a detecção de H2O2 em concentrações da ordem de 10-6 mol L-1. / In this work modified electrodes were developed and proceedings for their utilization in the detection of a variety of species with analytical importance, such as sulfite, ascorbic acid, nitrite, dopamine, NADH and hydrogen peroxide were investigated. During the studies, modified electrodes with films containing one porphyrin were developed and analytical applications with these sensors were done in association with flow injection analysis (FIA). These electrodes presented interesting catalytic properties for the oxidation of many species, increasing the current signal and changing the oxidation peaks of the analytes to the Ru(II)/(III) oxidation region. In these studies, it was necessary high concentrations of trifluormethanesulfonate in solution to avoid the gradual solubilization of the film from the electrode surface. This difficulty was surpassed by developing of modified electrodes with laminar films containing simultaneously two porphyrins, one cationic and other anionic. This new geration of modified electrodes exhibited excellent performance for analysis of the synthetic samples as much as real samples (sulfites in wines and ascorbic acid in juices and medicaments). The metalloporphyrins modified electrodes presented very high sensitivity (detection limit between 10-8 and 10-6 mol L-1), were able to minimize the poisoning effects of the sensor and are very easy to prepare. In this work were also performed some preliminary studies involving carbon paste electrodes doped with NdNiO3 oxide, which stand out specially due to anticipate the oxidation of hydrogen peroxide to 0.00 V in alkaline media. Analysis using batch injection analysis (BIA) makes possible the detection of H2O2 in the 10-6 mol L-1 level.
33

Desenvolvimento de processo de titulação por procura binária, em fluxo contínuo, com detecção espectrofotométrica / Development of titration process by search binary, in flow continuous, with spectrophotometric detection

Korn, Mauro 28 February 1996 (has links)
O processo de análise química denominado de titulação por procura binária foi desenvolvido e aplicado em sistema de injeção em fluxo. Este procedimento de análise, baseado no método das variações contínuas, procura o menor intervalo em fração volumétrica do titulante, ou da solução da amostra, que contenha o ponto final de uma titulação. Ao ser introduzida alíquota da solução da amostra no percurso analítico, o sinal gerado pelo detector deve ser significativamente diferente daquele gerado com a inserção de uma alíquota da solução do titulante. Neste processo descontínuo, a procura do ponto final segue a lógica binária, reduzindo os incrementos de fração volumétrica, da solução de amostra ou do titulante, em 50%, a cada nova tentativa de procura. Os sinais gerados por um detector espectrofotométrico, acoplado ao sistema de fluxo, eram convertidos em sinais digitais e comparados com os sinais fornecidos pelo detector nas duas tentativas iniciais da procura. Um programa foi desenvolvido para gerenciar este procedimento de titulação, determinando o volume das alíquotas das soluções, para cada tentativa, bem como estabelecendo a rota de procura. O procedimento foi aplicado à uma série de titulações envolvendo reações de neutralização e complexação. Uma titulação, aplicando este procedimento, pode ser executada em 3 minutos, consumindo aproximadamente 2 cm3 das soluções reagentes. As limitações para a aplicação deste procedimento de análise são discutidas, bem como a inviabilidade de sua aplicação sem o emprego de recursos de automatização. / A flow injection analytical procedure named as binary search titrimetric process was studied. It was based on volumetric fraction variation methodology. Under its directive, the microcomputer can control the titrand and titrant solutions delevering into the analytical path, by varying both volumetric fractions, following an algorithm based on successive aproximation method. Analytical signals assessed from the analog output of the spectrophotometer for each tentatives were converted to digital making use of an interface card, attached in the microcomputer main board. After each solutions handling cycles, the data collected were processed in order to decide about the next tentative to be carried out, obeying the settled binary search algorithm. The feasibility was ascertained by titrating solutions employing neutralization and complexation reactions. The time interval to perform this titration process employing binary search concept was about 3 minutes, consuming ca 2 cm3 of reagents solutions. No significant difference at 5 % probability level was observed by comparing of the results obtained applying this procedure with those produced by manual procedures.
34

Desenvolvimento de processo de titulação por procura binária, em fluxo contínuo, com detecção espectrofotométrica / Development of titration process by search binary, in flow continuous, with spectrophotometric detection

Mauro Korn 28 February 1996 (has links)
O processo de análise química denominado de titulação por procura binária foi desenvolvido e aplicado em sistema de injeção em fluxo. Este procedimento de análise, baseado no método das variações contínuas, procura o menor intervalo em fração volumétrica do titulante, ou da solução da amostra, que contenha o ponto final de uma titulação. Ao ser introduzida alíquota da solução da amostra no percurso analítico, o sinal gerado pelo detector deve ser significativamente diferente daquele gerado com a inserção de uma alíquota da solução do titulante. Neste processo descontínuo, a procura do ponto final segue a lógica binária, reduzindo os incrementos de fração volumétrica, da solução de amostra ou do titulante, em 50%, a cada nova tentativa de procura. Os sinais gerados por um detector espectrofotométrico, acoplado ao sistema de fluxo, eram convertidos em sinais digitais e comparados com os sinais fornecidos pelo detector nas duas tentativas iniciais da procura. Um programa foi desenvolvido para gerenciar este procedimento de titulação, determinando o volume das alíquotas das soluções, para cada tentativa, bem como estabelecendo a rota de procura. O procedimento foi aplicado à uma série de titulações envolvendo reações de neutralização e complexação. Uma titulação, aplicando este procedimento, pode ser executada em 3 minutos, consumindo aproximadamente 2 cm3 das soluções reagentes. As limitações para a aplicação deste procedimento de análise são discutidas, bem como a inviabilidade de sua aplicação sem o emprego de recursos de automatização. / A flow injection analytical procedure named as binary search titrimetric process was studied. It was based on volumetric fraction variation methodology. Under its directive, the microcomputer can control the titrand and titrant solutions delevering into the analytical path, by varying both volumetric fractions, following an algorithm based on successive aproximation method. Analytical signals assessed from the analog output of the spectrophotometer for each tentatives were converted to digital making use of an interface card, attached in the microcomputer main board. After each solutions handling cycles, the data collected were processed in order to decide about the next tentative to be carried out, obeying the settled binary search algorithm. The feasibility was ascertained by titrating solutions employing neutralization and complexation reactions. The time interval to perform this titration process employing binary search concept was about 3 minutes, consuming ca 2 cm3 of reagents solutions. No significant difference at 5 % probability level was observed by comparing of the results obtained applying this procedure with those produced by manual procedures.
35

DDesenvolvimento de eletrodos modificados e métodos analíticos / Development of modified electrodes and analytical methods

Carla Maria Nunes Azevedo 16 April 1999 (has links)
Neste trabalho foram desenvolvidos eletrodos modificados e procedimentos para a sua utilização na determinação de diversas espécies químicas de interesse analítico, dentre as quais sulfito, ácido ascórbico, nitrito, dopamina, NADH e peróxido de hidrogênio. Foram realizados estudos envolvendo eletrodos de carbono vítreo modificados com filmes contendo uma única metaloporfirina tetrarrutenada (catiônica) e aplicações analíticas destes sensores associando-os à análise por injeção em fluxo (FIA). Estes eletrodos apresentaram efeitos catalíticos sobre a oxidação de vários analitos, intensificando o sinal de corrente e deslocando seus picos de oxidação para a região de oxidação dos átomos de Ru(II) à Ru(III), sítios ativos das porfirinas. Contudo, para a obtenção de sensores estáveis, foi necessária a utilização de uma elevada concentração do contra-íon trifluorometanossulfonato em solução, prevenindo a gradual solubilização do filme modificador. Tal dificuldade foi contornada recobrindo-se os eletrodos com filmes laminares contendo simultaneamente pares de porfirinas catiônicas e aniônicas. Estes sensores apresentaram ação catalítica igual aos eletrodos recobertos por uma única porfirina, uma vez que os sítios ativos continuaram sendo os átomos de rutênio. Esta nova geração de eletrodos modificados exibiu excelente desempenho tanto em análises de amostras sintéticas, quanto de amostras reais (sulfitos em vinhos e ácido ascórbico em sucos e medicamentos). Os sensores modificados com metaloporfirinas apresentaram excelente sensibilidade (limites de detecção entre 10-8 e 10-6 mol L-1) e minimizaram os efeitos de envenenamento da superfície, além de serem de fácil preparo. No presente trabalho também foram realizados estudos preliminares envolvendo eletrodos de pasta de carbono dopados com o óxido misto de NdNiO3. Estes destacaram-se, principalmente, por antecipar a oxidação de peróxido de hidrogênio para 0,00 V em meio alcalino. Análises utilizando o sistema BIA (Batch Injection Analysis) possibilitaram a detecção de H2O2 em concentrações da ordem de 10-6 mol L-1. / In this work modified electrodes were developed and proceedings for their utilization in the detection of a variety of species with analytical importance, such as sulfite, ascorbic acid, nitrite, dopamine, NADH and hydrogen peroxide were investigated. During the studies, modified electrodes with films containing one porphyrin were developed and analytical applications with these sensors were done in association with flow injection analysis (FIA). These electrodes presented interesting catalytic properties for the oxidation of many species, increasing the current signal and changing the oxidation peaks of the analytes to the Ru(II)/(III) oxidation region. In these studies, it was necessary high concentrations of trifluormethanesulfonate in solution to avoid the gradual solubilization of the film from the electrode surface. This difficulty was surpassed by developing of modified electrodes with laminar films containing simultaneously two porphyrins, one cationic and other anionic. This new geration of modified electrodes exhibited excellent performance for analysis of the synthetic samples as much as real samples (sulfites in wines and ascorbic acid in juices and medicaments). The metalloporphyrins modified electrodes presented very high sensitivity (detection limit between 10-8 and 10-6 mol L-1), were able to minimize the poisoning effects of the sensor and are very easy to prepare. In this work were also performed some preliminary studies involving carbon paste electrodes doped with NdNiO3 oxide, which stand out specially due to anticipate the oxidation of hydrogen peroxide to 0.00 V in alkaline media. Analysis using batch injection analysis (BIA) makes possible the detection of H2O2 in the 10-6 mol L-1 level.
36

Stanovení beta-glukanů a pentosanů v surovinách pro výrobu piva a v pivu / Determination of beta-glucans and pentosans in raw materials for production of beer and in beer

Piškulová, Lenka January 2017 (has links)
The content of beta-glucans and arabinoxylans in barley grain, malt and wort was monitored. The varieties of barley were Pionier, Libuše, Manta, Tango, KWS Amadora, Kampa, KWS Irina, Francin, Odyssey, Overture, Vendela, Petrus, Laudis 550, Sunshine, Kangoo, Xanadu, Sebastian, Bojos and Malz. These varieties were grown on three different habitats (Uherský Ostroh, Věrovany and Vysoká u Příbramě). The content of beta-glucans and arabinoxylans was also analysed in five different types of beer. In brewing and malting industry the content of beta-glucans and arabinoxylans is mainly monitored because of their negative influence on decanting of wort and filtration of beer. These substances can contribute to turbidity and precipitation in beer and thus negatively effect the stability of beer. The content of beta-glucans in barley grain, malt, wort and beer was determined by FIA method and the content of arabinoxylans was determined in barley grain, wort and beer by Douglas method. The highest content of beta-glucans in barley grain was found in 14/19 varieties at Uherský Ostroh, where the amount of beta-glucan content was in the range of 3,65-5,60 %. The highest beta-glucan content in malt was found in 17/19 varieties at Vysoká u Příbramě, where the beta-glucan content was between 0,15-0,79 % and the highest content of beta-glucans in wort was found in 16/19 varieties also at Vysoká u Příbramě. There was the beta-content in the range of 22-184 mg/l. The results of content of arabinoxylans in barley grain and wort were more balanced. The highest content of arabinoxylans in barley grain was found in 10/19 varieties at Věrovany. The content of arabinoxylans at this habitat was in the range of 3,04-4,56 %. The highest content of arabinoxylans in wort was determined in 8/19 varieties at Uherský Ostroh. The content of arabinoxylans at this habitat was in the range of 542-1040 mg/l. The highest content of beta-glucans in samples of beer was determined in a sample of light lager (207 mg/l) and the highest content of arabinoxylans was found in a samle of wheat lager (1465 mg/l).
37

Průtoková injekční analýza vybraných glykosaminoglykanů se spektrofluorimetrickou detekcí / Flow injection analysis of selected glycosaminoglycans with spectrofluorimetric detection

Tichá, Renata January 2014 (has links)
The thesis is focused on a determination of heparin and chondroitin sulfate, using flow injection analysis with spectrofluorimetric detection. The determination is based on the interaction of negatively charged heparin, chondroitin sulfate resp., with a cationic dye (azure B or phenosafranine) which is manifested by the decrease in fluorescence intensity of the dye in its emission maximum. The optimal conditions for the determination in static mode were found, and calibration dependencies were measured. The conditions of FIA were optimized and following parameters were established: the volume of dispensed sample of 100 ml, the length of the reaction coil 60 cm, the flow rate 0.7 ml min-1 , the concentration of azure B 1.6×10-5 mol dm-3 , the concentration of phenosafranine 3.5×10-5 mol dm-3 . For the determination of heparin using azure B it was found: LOD = 0.023 IU ml-1 , LOQ = 0.186 IU ml-1 , and linear dynamic range 0.19-1.43 IU ml-1 . For the determination of heparin using phenosafranine it was found: LOD = 0.102 IU ml-1 , LOQ = 0.192 IU ml-1 , and linear dynamic range 0.19-1.79 IU ml-1 . For the determination of chondroitin sulfate using azure B it was found: LOD = 0.58 mg dm-3 , LOQ = 2.37 mg dm-3 , and linear dynamic range 2.37-8.32 mg dm-3 . The developed determination was applied to the...
38

Desenvolvimento de um sensor eletroquímico planar modificado com 1-2 Diaminobenzeno (DAB) para monitoração de nitrito por FIA-automatizada. / Development of a planar electrochemical sensor modified with 1-2 Diaminobenzene (DAB) for nitrite measuring by automatic FIA.

Almeida, Fernando Luis de 11 September 2009 (has links)
A presente dissertação de mestrado tem o propósito de relatar o desenvolvimento de um sensor planar eletroquímico com três eletrodos para o monitoramento de nitrito e seus interferentes (ácido úrico, ácido ascórbico e paracetamol). Para tal, no procedimento experimental é descrito o desenvolvimento do aparato extracorpóreo (mini-bomba compressora, válvulas solenóides e cela de análise). Esse é acoplado a um sistema de Análise por Injeção em Fluxo Automatizada (do inglês, Flow-injection Analysis) FIA-automatizada. Este trabalho também descreve a fabricação dos sensores em substrato de alumina, o processo de limpeza padrão dos eletrodos, o processo de obtenção dos eletrodos de referência em HCl (0,1 mol L-1) e ativação eletroquímica da superfície do eletrodo de trabalho com H2SO4 (0,1 mol L-1). Em seguida, é mostrada a estabilização dos eletrodos de referência Ag/AgCl em solução salina contendo cloretos, o estudo da secagem dos eletrodos em temperatura ambiente com exposição à luz e a caracterização dos mesmos por três métodos distintos, a saber: i) teste de reversibilidade (corrente redox vs. potencial); ii) variação do potencial com o tempo (coeficiente de degradação termodinâmica) e iii) variação do potencial com a concentração de cloretos. Também, apresenta-se a caracterização da área efetiva exposta do eletrodo de medição (trabalho) e os resultados da deposição de 1-2 Diaminobenzeno (DAB) como polímero seletivo. Além disso, são apresentados os resultados e discussões dos pseudo-eletrodos (recoberto ou não com Náfion® 117). Um ponto relacionado, a histerese associada à irreversibilidade dos eletrodos de referência resultou da ordem de 40 mVAg/AgCl Náfion® 117. Os potencias termodinâmicos observados foram da ordem de 100 ± 6 mVAg/AgCl Náfion® 117 para pseudo-eletrodo de referência sem e com Náfion® 117. Depois, foi realizado um estudo criterioso dos potenciais de resposta ao nitrito e aos interferentes por meio da técnica de DPV (do inglês, Differencial Pulse Voltammetry). Para evitar degradação acelerada (corrosão) do polímero sobre o eletrodo de trabalho, optou-se por realizar as medições com potencial igual a 0,50 VAg/AgCl Náfion® 117. Nessa condição, apresenta-se a monitoração de nitrito por FIA-automatizada na faixa de concentração de 50 a 250 mol L-1. Os resultados para a medição de nitrito mostraram que o sensor planar eletroquímico amperométrico desenvolvido é promissor, pois esse apresentou ótimo desempenho de reprodutividade (99,66%), sensibilidade (90 microA mol-1 L mm-2), seletividade (0,32%), repetitividade (91,28%) e estabilidade (15 ± 0,3 pA). / In this Master of Science, it has been developed an electrochemical planar sensor defined with three electrodes for nitrite measuring and its interferents (uric acid, ascorbic acid and paracetamol). In the experimental procedure, it is shown the development of an extracorporis set up (mini-pump, solenoid valves and analysis cell) which is coupled to a system of Flow-injection Analysis (FIA). This work also describes the sensor fabrication using alumina substrates, the standard cleaning of the electrodes, the process to obtain Ag/AgCl reference electrodes in HCl (0.1 mol L-1) and electrochemical activation of the working-electrode surface with H2SO4 (0.1 mol L-1). Following, it is shown the study of drying for electrodes at room temperature with exposition to room light and their characterization using three different methods: i) reversibility test (redox current vs. potential); ii) variation of the potential with the time (thermodynamics degradation coefficient) and iii) variation of the potential with the chloride concentration. Also, it is presented the characterization of the effective exposed area of the working electrode and the results of the deposited 1-2 Diaminobenzene (DAB) is presented as a selective polymer. In addition, the results and discussions of the pseudo-reference (recovered or not with Nafion® 117) are presented. Related to irreversibility is the hysteresis associated to the reference electrodes which resulted in the order of 40 mVAg/AgCl Nafion® 117. The observed thermodynamic potentials were of (100 ± 6) mVAg/AgCl Nafion® 117 for pseudo-electrodes recovered with Nafion® 117. Later on, a careful study of the response to nitrite and to its interferents was performed by means of the DPV technique (Differential Pulse Voltammetry). In order to avoid accelerated degradation (corrosion) of the polymer, measurements were performed at a potential of 0,5 VAg/AgCl Nafion® 117. In this condition, nitrite was monitored using the automatized-FIA (Flow Injection Analysis) for concentration in the range of 50 to 250 mol L-1. The results have shown that the planar amperometric sensor for nitrite measuring is usefull since it was observed excellent performance related to reproducibility (99.66%), sensitivity (90 microA mol-1 L mm-2), selectivity (0.32%), repetibility (91.28%) and stability (15.0 ± 0.3 pA).
39

Estudos eletroquímicos envolvendo eletrodos modificados por metaloporfirinas e aplicação na determinação de nitrato (NO3-) e nitrito (NO2-) / Electrochemical studies involving electrodes modified by metalloporphyrins and application in the determination of nitrate (NO3-) and nitrite (NO2-)

Rocha, José Roberto Caetano da 06 February 2001 (has links)
O presente trabalho inclui duas etapas da pesquisa. Na primeira fase do projeto, a oxidação eletroquímica do nitrito em eletrodo de carbono vítreo modificado com um filme obtido eletrostaticamente de Co-TRP/Zn-TPPS, foi investigada em pH 4,7. Um aumento de corrente foi detectado em 0,75V, cujo máximo foi proporcional à concentração do íons nitrito, exibindo uma dependência inversa com a espessura do filme. A velocidade de transferência de carga foi avaliada por cronoamperometria, sendo que a velocidade de difusão da carga eletroquímica através do filme é mais alta do que a velodicade de difusão do íon em solução. O processo catalítico envolvendo a oxidação do íon nitrito no filme de pares de depósitos alternados foi também investigado com as técnicas da voltametria cíclica e de disco rotativo. Em concentrações relativamente baixas de substrato, o processo mediado foi tratado como um sub-caso, SR, na notação de Saveant, permitindo o cálculo da constante de velocidade para a reação de troca na interface filme-solução, sendo que tal valor foi estimado em 3,4x103 dm3 mol-1 s-1. Na segunda parte da investigação, a potencialidade analítica do eletrodo modificado foi confirmada por experimentos de injeção em fluxo usando solução carregadora tampão pH 4,7. Devido à atividade catalítica da camada imobilizada, a determinação de nitrito foi realizada em potencial menos positivo do que aqueles obtidos em eletrodos polidos (0,75 V vs. Ag/AgCl) e os dados obtidos demostraram o melhor desempenho do eletrodo modificado, indicando excelente repetibilidade e maior sensibilidade. Na condição experimental otimizada, o nitrito foi determinado na configuração FIA com limite de detecção de 0,1 &#181mol L-1 e a faixa analítica de aplicabilidade do método foi de 1 a 1000 µmol L-1. Nitrato também foi quantificado após sua redução estequiométrica a nitrito pela passagem da solução através da coluna de cádmio/cobre. Ambos analitos foram quantificados em água mineral e amostras de saliva e os resultados foram concordantes com aqueles obtidos usando método oficial. / This present work includes two research steps. ln the first step the electrochemical oxidation on nitrite on a glassy carbon disc electrode, modified with an electrostatically assembled film of tetraruthenated cobalt porphyrin/(meso-tetra(4-sulphonatephenyl)porphyrinate zinc(II), was investigated at pH = 4.7. A current enhancement was observed by using the modified electrode, the signal being proportional to the concentration of nitrite ions and exhibiting an inverse dependence with the film thickness. The charge transfer rate was evaluated by chronoamperometry, showing that the rate of diffusion of electrochemical charge through the film is higher than the rate of diffusion of substrates in solution. The catalytic process involving the oxidation of the nitrite ions at the bilayered film was also investigated based on cyclic and rotating disc voltammetry. At relatively low substrate concentrations the mediated process has been dealt with in terms of the SR sub-case in Saveant\'s notation, allowing the calculation of the rate constant for the cross-exchange reaction at the film-solution interface as 3.4x103 dm3 mol-1 s-1. In the second part the analytical potentiality of the modified electrode was studied by flow injection experiments carried out by using a pH 4.7 buffer as carrier solution. Owing to the catalytic activity of the immobilized layer, the determination of nitrite was performed at less positive potentials (0.75 V versus Ag/AgCl) and the data obtained showed a better performance indicated by both an excellent repeatability and increased sensitivity. At the optimized experimental condition, nitrite was determined in the FIA configuration with a limit of detection of 0.1 µmol L-1. Nitrate was also quantified after its stoichiometric reduction to nitrite by passing the solution through a cadmium/copper column. Both analytes were quantified in mineral water and saliva samples and the results were in agreement with the ones obtained by using an official method.
40

Desenvolvimento, comparação e aplicação forense de sistemas de injeção em banho e injeção em fluxo, com detecção voltamétrica de chumbo em eletrodo de mercúrio / Development, comparison and forensic application of injection and flow injection systems with voltammetric detection of lead in mercury electrode

Donato, Adriana De 10 August 2001 (has links)
Para determinar baixas concentrações de chumbo, oriundo de resíduos de disparo de armas de fogo, aplicou-se a voltametria de redissolução anódica, ASV, com pulso diferencial, PD, para detecção do metal em eletrodo de gota pendente de mercúrio, EGPM. A etapa de redução se dava a -0,6 V vs. Ag/AgCl, durante 25s, com imediata varredura até -0,3V vs. Ag/AgCl. O pico de reoxidação do chumbo surgia a -0,42V vs. Ag/AgCl. A injeção de amostras foi bastante facilitada pela aplicação do sistema de análise por injeção em banho, BIA onde um pequeno volume de amostra é injetado, com o auxílio de um micropipetador automático, diretamente sobre um detector imerso em um volume várias vezes maior que aquele da amostra. Com o intuito de estender a técnica ao EGPM comercial, um adaptador simples, em forma de J, foi desenvolvido e aplicado, o qual dirige o fluxo descendente do micropipetador para cima, diretamente sobre a gota de mercúrio. Foi dada a presença de chumbo, da ordem de 1 ppm, quando se amestrava as mãos encontro de voluntários, do Instituto de Criminalística da Polícia Científica do Estado de São Paulo, com tiras de fita crepe antes e depois de um conjunto de disparos. A extração do chumbo foi feita através da agitação de cada tira de fita crepe, apoiada em tela de Nylon®, com uma mistura de clorofórmio e HCl 0,1 M, com a fase aquosa sendo levada a posterior análise. Outros métodos de coleta também foram testados. Nota-se, também, que é possível determinar o mesmo analito em sistemas de injeção em fluxo, após desoxigenação do eletrólito suporte. Com o uso da técnica de pulso reverso, a desoxigenação pode se tornar desnecessária. / In order to determine low concentrations of lead, originated from gunshot residues, anodic stripping voltammetry, ASV, with differential pulse, DP, was applied to detect the metal in a hanging mercury drop electrode, HMDE. The reduction step was done at -0.6 V vs. Ag/AgCl, for 25s, followed by the immediate scan up to -0.3V vs. Ag/AgCl. The reoxidation current peak appeared at -0.42V vs. Ag/AgCl. The injection of samples was greatly facilitated by the application of the batch injection analysis system, BIA, where a small sample volume is injected, with the aid of an automatic micropipettor, directly onto the detector, which is immersed in a volume many times larger than the sample. Aiming the application of the technique with commercial HMDE, a simple J-shaped adapter was developed and applied, which directs upwards the descending flow of the micropipettor, rightly over the mercury drop surface. The presence of lead was observed at around 1 ppm, after sampling the hands of volunteers, from the Institute of Criminalistics of the Scientific Police of São Paulo State, with strips of adhesive tapes before and after a set of gunshots. Lead extraction was performed shaking each strip, over a Nylon® screen, in a mixture containing chloroform and HCl 0.lM, with the posterior analysis of the aqueous phase. Other collection methods were also tried. It is also possible to determine the same analyte in a flow injection system, after the deoxygenation of the supporting electrolyte. With the aid of the reverse pulse technique, the deoxygenation may become unnecessary.

Page generated in 0.4083 seconds