• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 418
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 435
  • 211
  • 109
  • 105
  • 104
  • 88
  • 84
  • 78
  • 71
  • 65
  • 61
  • 52
  • 51
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Tratabilidade de efluentes de indústrias de cosméticos capilares para redução de toxicidade / Treatability of hair care products industry wastewaters for reduction of toxicity

Melo, Elisa Dias de 20 June 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-06-06T12:00:53Z No. of bitstreams: 1 texto completo.pdf: 1865685 bytes, checksum: 312c6ff5ca16a7cd5c2b8bd1317dbe0e (MD5) / Made available in DSpace on 2017-06-06T12:00:53Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1865685 bytes, checksum: 312c6ff5ca16a7cd5c2b8bd1317dbe0e (MD5) Previous issue date: 2016-06-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As indústrias de cosméticos têm grande importância na economia nacional, com elevada representação por empreendimentos de pequeno e médio porte. Os processos produtivos desses empreendimentos são responsáveis pela geração de efluentes considerados de grande potencial poluidor, devendo ser tratados adequadamente antes de seu lançamento. A presente pesquisa teve como objetivo o estudo da tratabilidade de efluentes líquidos provenientes de duas indústrias de cosméticos capilares de pequeno porte. O levantamento bibliográfico realizado apontou lacunas no que se refere ao tratamento de efluentes dessa tipologia industrial, tanto com relação às técnicas de tratamento, considerando por exemplo a variabilidade dos efluentes reais, quanto à importância em se considerar a redução da carga tóxica dos mesmos. Uma batelada de testes de toxicidade com espécies de três níveis tróficos (produtores primários e consumidores primários e secundários) indicaram os microcrustáceos Daphnia similis e Ceriodaphnia dubia como organismos-teste mais sensíveis aos efluentes brutos gerados pelas indústrias de cosméticos capilares, embora tenha sido observada elevada sensibilidade das demais espécies testadas (Raphidocelis subcapitata, Hyalella azteca e Danio rerio). A menor toxicidade foi observada para o peixe D. rerio, com índice CE(I)50 de 2,7 %, o que ainda representa elevada toxicidade aguda. Estudos de tratabilidade por ensaios em escala de bancada foram realizados para processos físico-químicos de coagulação/floculação, processos de separação por membranas de ultrafiltração e nanofiltração e combinação desses com processo de adsorção em carvão ativado em pó. Os tratamentos físico-químicos permitiram elevadas reduções de turbidez e óleos e graxas. Foram também alcançadas, em maior ou menor grau, reduções da DQO total e toxicidade, mas somente após a adsorção foram obtidas reduções de matéria orgânica dissolvida. Testes de biodegradabilidade aeróbia e anaeróbia indicaram a viabilidade do tratamento biológico, mas com questões ainda a serem elucidadas, como a contribuição de processos abióticos na redução da matéria orgânica e o efeito de subprodutos ou metabólitos das reações biológicas sobre a toxicidade das amostras tratadas. / The cosmetic industry contributes greatly to the national economy, with a high percentage of small and medium-sized enterprises. Despite major financial constraints, the small-scale industrial processes are responsible for wastewater generation with high pollution potential that should be treated appropriately before released to the environment. This research aimed to study the treatability of two small hair care products industries wastewaters. The technical literature revealed shortcomings in cosmetic industry wastewater treatment, regarding treatment techniques, considering the large variability in wastewater quality, as well as the need for toxicity reduction. Toxicity tests were performed with aquatic species from three trophic levels (primary producers and primary and secondary consumers) and indicated microcrustaceans Daphnia similis and Ceriodaphnia dubia as the most sensitive test organisms, although all species (Raphidocelis subcapitata, Hyalella azteca and Danio rerio) showed high sensitivity, with the highest toxicity index (lowest toxicity) found for the fish D. rerio (2,7 %). Bench-scale treatability studies were performed, including coagulation/flocculation physicochemical processes and membranes filtration. Both of these techniques were also combined with powdered activated charcoal adsorption. Physicochemical treatments reduced turbidity and oils and greases. They also achieved some degree of toxicity and total COD reductions, but dissolved organic matter content was only reduced after adsorption. Aerobic and anaerobic biodegradability tests indicated the feasibility of applying biological treatment at full scale, but there are still points to be elucidated, such as the contribution of abiotic processes in the reduction of organic matter and the effects of by-products or microbial metabolites on the toxicity of treated wastewaters.
92

Alterações renais em pacientes com doença falciforme / Renal abnormalities in patients with sickle cell disease

Silva Júnior, Geraldo Bezerra da January 2013 (has links)
SILVA JUNIOR, Geraldo Bezerra da. Alterações renais em pacientes com doença falciforme. 2013. 136 f. Tese (Doutorado em Ciências Médicas) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2013. / Submitted by denise santos (denise.santos@ufc.br) on 2013-12-09T12:22:34Z No. of bitstreams: 1 2013tese_gbsilvajúnior.pdf: 4020270 bytes, checksum: 932d626cfa365d0e98cb57131da52b12 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2013-12-09T12:23:23Z (GMT) No. of bitstreams: 1 2013tese_gbsilvajúnior.pdf: 4020270 bytes, checksum: 932d626cfa365d0e98cb57131da52b12 (MD5) / Made available in DSpace on 2013-12-09T12:23:23Z (GMT). No. of bitstreams: 1 2013tese_gbsilvajúnior.pdf: 4020270 bytes, checksum: 932d626cfa365d0e98cb57131da52b12 (MD5) Previous issue date: 2013 / Background - Kidney abnormalities are one of the main chronic complications of sickle cell disease (SCD). The aim of this study is to investigate the occurrence of renal abnormalities among patients with SCD. Methods - This is a cohort study with 26 SCD patients followed in a medical center in Fortaleza, Ceará, Brazil. Urinary acidification and concentration tests were performed using calcium chloride (CaCl2), and after a 12h period of water and food deprivation. Fractional excretion of sodium (FENa), transtubular potassium gradient (TTKG) and solute free water reabsorption (TcH2O) were calculated. The SCD group was compared to a group of 15 healthy volunteers (control group). Aquaporin-2 (AQP2) and renal outer medullary K+ channels (ROMK) were quantified through exosomes search in urine. Results - Patient`s average age and gender were similar to controls. Urinary acidification deficit was found in 5 SCD patients (19.2%), who presented urinary pH > 5.5 after CaCl2 test. Urinary osmolality was significantly lower in SCD patients (355±60 vs. 818±202mOsm/kg, p=0.0001, after 12h period water deprivation). Urinary concentration deficit was found in all SCD patients (100%). FENa was higher among SCD patients (0.75±0.3 vs. 0.55±0.2%, p=0.02). The TTKG was higher in SCD patients (5.5±2.5 vs. 3.0±1.5, p=0.001), and TcH2O was lower (0.22±0.3 vs. 1.1±0.3L/day, p=0.0001). The search for AQP2 did not show significant difference between SCD patients and control group (102±6.0 vs. 100±7.2%, p=0.874), as well as for ROMK (172±38 vs. 100±25%, p=0.207). Conclusions - SCD is associated with important kidney dysfunction. The main abnormalities found were urinary concentrating and incomplete distal acidification defect. There was also an increase in the potassium transport and decrease in water transport, evidencing the occurrence of distal tubular dysfunction. / Introdução - Alterações renais representam uma das complicações crônicas principais da doença falciforme (DF). O objetivo deste estudo é investigar a ocorrência de alterações renais em pacientes com DF. Métodos - Foi realizado estudo de coorte com 26 pacientes com DF acompanhados em um ambulatório de Fortaleza, Ceará, Brasil. Testes de acidificação e concentração urinárias foram realizados usando cloreto de cálcio (CaCl2) e após período de 12h de jejum e privação hídrica. Foram calculados fração de excreção de sódio (FENa), transporte transtubular de potássio (TTKG) e transporte de água livre de solutos (TcH2O). O grupo de pacientes com DF foi comparado com um grupo de 15 voluntários sadios (grupo controle). Os transportadores aquaporina-2 (AQP2) e canal de K+ apical (ROMK) foram quantificados pela pesquisa de exossomas na urina. Resultados - A média de idade e a distribuição de gênero foi similar entre os dois grupos. Déficit de acidificação urinária foi encontrada em 5 pacientes com DF (19,2%), que apresentaram pH urinário > 5,5 após o teste com CaCl2. A osmolaridade urinária foi significativamente menor entre os pacientes com DF (355±60 vs. 818±202mOsm/kg, p=0,0001, após período de 12h de jejum e privação hídrica). Déficit de concentração urinária foi encontrado em todos os casos de DF (100%). A FENa foi maior entre os pacientes com DF (0,75±0,3 vs. 0,55±0,2%, p=0,02). O TTKG também foi maior nos pacientes com DF (5,5±2,5 vs. 3,0±1,5, p=0,001), e o TcH2O foi menor (0,22±0,3 vs. 1,1±0,3L/dia, p=0,0001). A pesquisa de AQP2 não mostrou diferença significativa em relação ao grupo controle (102±6,0 vs. 100±7,2%, p=0,874), bem como a do canal ROMK (172±38 vs. 100±25%, p=0,207). Conclusão - A DF é associada a importantes alterações renais. As principais alterações encontradas foram déficit de concentração e acidificação urinária. Foi ainda observado aumento no transporte
93

Cinética de desinfecção viral em água de consumo humano mediante exposição ao cloro, utilizando como modelo o adenovírus recombinante

Nascimento, Mariana de Almeida do January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Biológicas, Programa de Pós-Graduação em Biotecnologia e Biociências, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:08:08Z (GMT). No. of bitstreams: 1 326940.pdf: 2274596 bytes, checksum: 074ce9d264a989af3e9bdace4790ce98 (MD5) Previous issue date: 2014 / No Brasil, a Portaria MS 2.914/2011 exige a ausência de coliformes totais e E. coli na água tratada, entretanto é fundamental que o tratamento seja eficiente para todos os microrganismos patogênicos. A desinfecção nas Estações de Tratamento de Água (ETA) é comumente realizada com cloro. O adenovírus recombinante (rAdV) expressa proteína verde fluorescente (GFP) quando se replica nas células HEK 293A, e foi escolhido, como um modelo para avaliar a eficiência de desinfecção em amostras de água filtradas de duas ETAs (Lagoa do Peri (pH 6.9) e Morro dos Quadros (pH 6.5)), a 15°C e 20°C e com 0,2 mg/L e 0,5 mg/L de cloro livre. O tampão livre de demanda de cloro (BDF) (pH 6.9 e 8.0) foi utilizado como controle. As amostras foram caracterizadas físico-quimicamente e quanto ao padrão bacteriológico. A partir da curva da expressão da GFP, foi escolhido o período de 24h pós-infecção para os ensaios de citometria de fluxo (FACS) e microscopia de fluorescência (MF). Após padronizadas, as técnicas apresentaram como limite de detecção a diluição viral de 10-4 (FACS) e 10-6 (MF), sendo a MF escolhida para averiguar a inativação de rAdV por cloro. A técnica de qPCR foi escolhida como método molecular. O tempo necessário para inativar 4log10 de rAdV foi menor que 1 min (para 0,2 mg/L e 0,5 mg/L de cloro livre), utilizando MF, com exceção do BDF pH 8.0 (acima de 2,5 min para 4log10). O pH (6,5, 6,9 e 8.0) exerceu grande influência na eficiência de desinfecção. O ensaio de qPCR não forneceu informações a respeito de rAdV inativado. Os dados foram modelados (Chick-Watson) e observado que os valores de Ct para inativação de 4log10 foi menor que 0,25 para todas as condições experimentais, com exceção do BDF pH 8.0, com Ct acima de 1,249. Os valores de Ct são comparáveis aos reportados na literatura e menores do que os recomendados pela EPA. O modelo demonstrou ter se ajustado bem às condições experimentais realizadas e observadas. Também foram coletadas amostras de água tratada das ETAs (na saída da ETA e na rede de distribuição) e avaliado para coliformes totais, E. coli e adenovírus humano (HAdV), que foi detectado na rede de distribuição da ETA Morro dos Quadros (2,75.10³ UFP/L). Finalmente, foi possível comprovar que os adenovírus são rapidamente inativados em águas superficiais tratadas com cloro e que os adenovírus recombinantes mostraram-se bons modelos para esta avaliação.<br> / Abstract : In Brazil, the MS 2.914/2011 ordinance requires the absence of total coliforms and E. coli in treated water, however it is essential that water treatment is effective for all pathogens. Disinfection in Water Treatment Plants (WTP) is commonly performed with chlorine. The recombinant adenovirus (rAdV) expresses green fluorescent protein (GFP) when replicates in HEK 293A cells, and was chosen as a model to evaluate the efficiency of disinfection in filtered water samples from two WTP (Lagoa do Peri (pH 6.9) and Morro dos Quadros (pH 6.5)) under 15 ° C and 20 ° C with 0.2 mg/L and 0.5 mg/L free chlorine. Buffered demand free (BDF) (pH 6.9 and 8.0) was used as control. The samples were characterized physico-chemically as well for bacteriological standards. From curve of GFP expression, the 24-hour period post-infection for flow cytometry assays (FACS) analysis and fluorescence microscopy (FM) was selected. After standardized, techniques showed a detection limit for viral dilution of 10-4 (FACS) and 10-6 (FM) and FM was selected to investigate the decay of rAdV by chlorine. qPCR technique was employed as a molecular method. The time required to inactivate 4log10 of rAdV was less than 1 min (for 0.2 mg/L and 0.5 mg/L) using FM, except for BDF pH 8.0 (up to 2.5 min for 4log10). The pH (6.5, 6.9 and 8.0) had a great influence on the efficiency of disinfection. The qPCR assay was not able to provide information regarding rAdV inactivated. The data were modeled (Chick-Watson) and observed that the Ct values for inactivation of 4log10 was less than 0.25 for all experimental conditions, except for the BDF pH 8.0, with Ct over 1.249. The Ct values are comparable to those reported in the literature and smaller than those recommended by EPA. The model proved to have adjusted well to the experimental conditions used and observed. Samples of treated water from WTP (at the output of WTP and the distribution network) were evaluated for total coliforms, E. coli and human adenovirus (HAdV), which was detected in the distribution network of WTP Morro dos Quadros (2,75.10³ UFP/L). Finally, it was possible to prove that adenoviruses were rapidly inactivated in surface water treated with chlorine and that recombinant adenovirus proved to be good models for this evaluation.
94

Influência da técnica de limpeza de filtros lentos e diâmetro dos grãos sobre a qualidade da água produzida, com destaque para remoção de carbamatos e oocistos de Cryptosporidium (simulados por microesferas)

Pizzolatti, Bruno Segalla January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2014 / Made available in DSpace on 2015-02-05T20:27:41Z (GMT). No. of bitstreams: 1 331124.pdf: 14405855 bytes, checksum: f77c07e4675734e6ca2daa670f9a9367 (MD5) Previous issue date: 2014 / Neste trabalho, buscou-se avaliar a tecnologia da filtração lenta retrolavável no tratamento de água de lago com vistas a suprir as necessidades de consumo humano. Foram propostas duas formas de retrolavagem, utilizando a água filtrada ou bruta, sempre, comparadas a um filtro controle com limpeza por raspagem. O objetivo da pesquisa foi avaliar a eficiência dos filtros no tocante a parâmetros físicos, químicos (com destaque para carbamatos: metomil, carbofurano e carbaril) e biológicos (simulados por microesferas fluorescentes), bem como avaliar a eficiência da retrolavagem em filtros lentos. Foram construídos dois sistemas de filtração, sendo um em escala real e outro em escala piloto. Todas as unidades de filtração eram de escoamento descendente, operaram com taxa de filtração de 4 m3/m2 dia e carga hidráulica variável. Durante o monitoramento dos filtros em escala real, foi possível realizar 18 de filtração válidas, em que não se observou diferença significativa de duração entre os filtros controle (FLC) e os filtros retrolaváveis com água filtrada (FLR) e com água bruta (FLRb). Com relação aos parâmetros de qualidade de água cor e turbidez, o FLC teve melhor desempenho que os demais filtros no tocante cor aparente e verdadeira e com relação a remoção de cianobactérias o filtro FLR obteve melhor desempenho. Nos filtros em escala piloto, nos quais foram avaliados os contaminantes específicos (microesferas e carbamatos), formaram um total de seis filtros, agrupados dois a dois (filtros lentos convencionais/retrolaváveis), em que cada grupo de filtros tinha diâmetro efetivo do material filtrante distintos. A granulometria do material filtrante não pareceu interferir na qualidade da água, no entanto o método de limpeza mostrou que os filtros com limpeza por raspagem foram mais efetivos que seus pares retrolaváveis na maior parte dos parâmetros analisados. Para os carbamatos estudados, observou-se remoção máxima de 19,30, 36,94 e 63,80% para o metomil, carbofurano e carbaril respectivamente, não sendo observada também diferença significativa entre os filtros avaliados. Para as microesferas, todos os filtros alcançaram eficiência de 4,75 Log, depois de 8 horas de filtração. Em função dos resultados obtidos, pode-se considerar que o trabalho contribui para facilitar a operação de filtros lentos, com adoção da retrolavagem, o que pode resultar no aumento do uso desta tecnologia principalmente em comunidades isoladas, desprovidas de tratamento e abastecimento público de água.<br> / Abstract: This study aimed to evaluate the backwash slow sand filtration technology in treatment of lake water in order to solve the needs of human consumption. Two forms of backwash were proposed, using filtered and raw water, always compared with a control filter cleaned by scraping. The research objective was to evaluate the efficiency of filtersin relation to physical, chemical parameters (specially carbamates: methomyl, carbofuran and carbaryl) and biological (simulated by fluorescent microspheres), as well as the efficiency of backwash in slow sand filters. Two pilot systems were built a real scale and other smallscale. All filter units are downflow, operated with filtration rate of 4m3/m2dia and hydraulic head variable. During monitoring of full-scale filters, was possible to carry 18 filtration run where no significant difference was observed in duration between the filter control (FLC) and backwashed filter with filtered water (FLC) and raw water (FLRb). Regarding water quality parameters color and turbidity the FLC performed better than other filters regarding apparent and true color, with respect to the removal of cyanobacteria FLR filter performed better than others filters. In small-scale filters which were evaluated specific contaminants (microspheres and carbamates) are a total of six filters, grouped two by two, forming three sets of conventional / backwash slow sand filter where each filter group had distinct effective diameter. The diameter of the filter material did not appear to affect the quality of water however, but scraping method of cleaning was more effective than their backwashed pairs, in most parameters. For carbamates studied the maximum removal of 19,30, 36, 94 and 63,80% for methomyl, carbaryl and carbofuran, respectively, there was no significant difference between the evaluated filters. For all filters microspheres efficiency reached 4,75 log after eight hours of filtration. Depending on the results obtained, it can be considered that the work helps to facilitate the operation of slow sand filters, with adoption of backwash in slow sand filters, and could result in an increased use of this technology especially in isolated communities, which have no treatment and supply of drinking water.
95

Esferas de poliestireno como elemento filtrante em filtração rápida descendente

Schöntag, Juliana Marques January 2015 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2015. / Made available in DSpace on 2015-09-29T04:08:34Z (GMT). No. of bitstreams: 1 334522.pdf: 7395807 bytes, checksum: c5404020b1cc14073727ba2c446f1652 (MD5) Previous issue date: 2015 / Problemas constantes encontrados em sistema de tratamento e distribuição de água e o crescente aumento do custo de produção, devido à degradação da qualidade da água disponível vêm motivando pesquisas por novas soluções em tratamento e obtenção de maiores produções efetivas. Com esse intuito, esse trabalho propôs o estudo de um material leve e reutilizável. As esferas poliméricas de poliestireno apresentaram-se como uma alternativa, pois além de serem leves e inertes têm características similares a de uma areia grossa e estão disponíveis comercialmente. Primeiramente, caracterizou-se esse material que apresentou granulometria entre 0,5 e 1,2 mm, diâmetro específico de 0,68 mm, coeficiente de uniformidade de 1,36 e massa específica de 1046 kg/m³. Após a caracterização desse material, simulou-se matematicamente a utilização como elemento filtrante, em aspectos como o coeficiente de permeabilidade do leito filtrante e especialmente parâmetros pertinentes à retrolavagem. Os parâmetros simulados demonstraram que, apesar de possível, a utilização desse material necessita de suporte (como a aplicação do ar) para atingir uma quantidade satisfatória de cisalhamento com baixas velocidades e elevado grau de expansão durante a retrolavagem.A qualidade da água produzida pelo filtro com as esferas de poliestireno foi bastante similar ao filtro de dupla camada de areia e antracito, contudo a produção efetiva, não apresentou grande superioridade, mesmo com o sistema otimizado. Apesar disso, o material demonstrou potencialidades em gerar uma economia ao sistema de tratamento, que ainda precisam ser melhor exploradas.Verificou-se através de ensaios experimentais que o índice de filtração manteve-se constante ao longo da filtração e a ação da profundidade atingida pelo leito ficou em torno de 40 cm, quando utilizada como fonte de água bruta o manancial Lagoa do Peri. Além desses fatores foi avaliada a capacidade adsortiva desse material, utilizando como adsorvato o azul de metileno. Esse material demonstrou baixa capacidade adsortiva devido ao baixo grau de rugosidade da sua superfície, a ação adsortiva é física, não espontânea, envolvendo fracas forças de atração.<br> / Abstract : Constant troubles in treatment system and water supply and the increasing cost of production due to deterioration of available quality water come motivating research for new solutions in treatment and higher effective production. This paper proposed the studies in a lightweight, reusable material. The granules of polystyrene were presented as an alternative, because are light, inerts and are assimilares to sand characteristics and were commercially available. First, this material was characterized and presented a grain size between 0.5 and 1.2 mm, specific diameter of 0.68 mm and specific mass of 1046 kg / m³. Based on the extracted characteristics were simulated mathematically using this material as a media filter, besides of permeability coefficient, especially parameters to backwash, which can be demonstrate that special care would need to achieve a satisfactory backwash, showing low shear rates and a high degree of expansion. Through of experimental analysis were found that the filtration rate remained constant throughout the filtration, and the bed depth achieved 40 cm, when used as raw water Peri Lagoon source. In addition was evaluated adsorptive capacity of the material, using as the adsorbate Methylene blue. This material showed low adsorption capacity due to the low roughness, the adsorptive action is physical, not spontaneous involving weak forces of attraction.The quality of the water produced by the filter to the polystyrene granules was very similar to the dual filter layer of sand and anthracite, but the effective production did not show significative superiority, even with optimized system. Nevertheless, the material demonstrated potential to generate savings to the treatment system, which still need to be better exploited.
96

Estudo teórico-experimental de uma caldeira de queimador poroso recíproco aplicado ao biogás / Theoretical and experimental study of reciprocal porous burner applied to biogas

Souza, Luís Carlos Eduardo Oliveira de 27 March 2009 (has links)
SOUZA, L. C. E. O. Estudo teórico-experimental de uma caldeira de queimador poroso recíproco aplicado ao biogás. 156 f. 2009. Dissertação (Mestrado em Engenharia Mecânica) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2009. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-03-21T16:23:53Z No. of bitstreams: 1 2009_dis_lceosouza.pdf: 10773142 bytes, checksum: a11aac07ac8b8e7c278525c356a8db0f (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-03-31T14:47:56Z (GMT) No. of bitstreams: 1 2009_dis_lceosouza.pdf: 10773142 bytes, checksum: a11aac07ac8b8e7c278525c356a8db0f (MD5) / Made available in DSpace on 2016-03-31T14:47:56Z (GMT). No. of bitstreams: 1 2009_dis_lceosouza.pdf: 10773142 bytes, checksum: a11aac07ac8b8e7c278525c356a8db0f (MD5) Previous issue date: 2009-03-27 / The current Dissertation treats the theoretical and experimental studies about a non- conventional saturated steam boiler, in which a com bustion technology is employed, the “Filtration Combustion”, as basis for conception of its burner construction design. This combustion thermal system was studied by means of a prototype, in laboratory scale, specially developed for this research. It was prop erly instrumented in order to make it possible to monitor as well as the combustion proce ss as the energy extraction in the reaction zone. The objective of this investigation is to verify the effects of the Biogas obtained from the anaerobic digestion of the Green Coconut Skin Liquid (GCSL), on the boiler operation, concerning efficiency and polluta nt emissions, as well as the reaction stability. Biogas combustion is analyzed by numeri cal model simulations, which take in account the mass, energy (gas and solid phases) and species conservation equations. The model is structured with a flexible code in languag e FORTRAN, which includes equilibrium calculation performed through premixed combustion simulation software, the PREMIX, adapted to the combustion process and heat transfer in porous medium. The simulation allows the prediction of the temperature distribution profiles along the burner and the combustion products as function of two main operation parameters, the equivalence ratio and the air-fuel mixture flow vel ocity. Simulation results are compared with measurements in this analysis and some design aspects of the "Porous Burner Boiler” are discussed, which evidences its operational adva ntages in comparison to the conventional boilers, especially the high energy ex traction efficiency and low carbon and nitrogen oxides emission levels / A presente Dissertação de Mestrado trata do estudo teórico-experimental de uma caldeira de vapor saturado não-convencional, onde é empregada uma tecnologia de combustão, a “Combustão de Filtração”, como base pa ra concepção do projeto construtivo do seu queimador. Esse sistema térmico de combustã o foi estudado através de um protótipo especialmente desenvolvido para essa pesq uisa, em escala de laboratório. O protótipo foi instrumentado adequadamente, de forma a possibilitar o monitoramento tanto do processo de combustão como da extração de energi a da zona de reação. O objetivo da pesquisa foi verificar os efeitos do Biogás obtido da digestão anaeróbia do líquido da casca do coco verde (LCCV), sobre a operação da caldeira, no que diz respeito à eficiência e às emissões, como também, quanto à estabilidade de rea ção. A combustão do biogás é analisada com a ajuda de um modelo numérico de simu lação, o qual é constituído das equações de conservação da massa, da energia (nas f ases gás e sólida) e das espécies. Esse modelo é estruturado por um código flexível, em lin guagem FORTRAN, que incorpora o cálculo das composições de equilíbrio por meio de u m programa de simulação de combustão pré-misturada, o PREMIX, adaptado para pr ocessos de combustão e de transferência de calor em meio poroso. A simulação permite predeterminar os perfis de distribuição de temperatura ao longo do queimador e os produtos de combustão em função dos dois parâmetros principais de operação, a razão de equivalência e a velocidade do escoamento da mistura ar-combustível. Os resultado s de simulação são confrontados com os dados experimentais nessa análise, e são discuti dos alguns aspectos de projeto da “Caldeira de Queimador Poroso Recíproco”, que ressa ltam suas vantagens operacionais em relação às caldeiras convencionais, especialmente a elevada eficiência de extração de energia e os baixos níveis de emissões de óxidos de carbono e nitrogênio
97

Dupla filtração utilizando filtro de pressão à montante de filtro ascendente em manaciais eutrofizados / Double Filtration Using Pressure Filter Upstream Of The Rising Filter In Eutrophic Body Os Water

Lima, José Airton Pereira 17 June 2011 (has links)
LIMA, J. A. P. Dupla filtração utilizando filtro de pressão à montante de filtro ascendente em manaciais eutrofizados. 2011. 94 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-13T17:46:30Z No. of bitstreams: 1 2011_dis_japlima.pdf: 1958448 bytes, checksum: 72c7a36501667a4481d0c7266de3e487 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-16T19:06:02Z (GMT) No. of bitstreams: 1 2011_dis_japlima.pdf: 1958448 bytes, checksum: 72c7a36501667a4481d0c7266de3e487 (MD5) / Made available in DSpace on 2016-05-16T19:06:02Z (GMT). No. of bitstreams: 1 2011_dis_japlima.pdf: 1958448 bytes, checksum: 72c7a36501667a4481d0c7266de3e487 (MD5) Previous issue date: 2011-06-17 / The process of treatment by direct filtration is often selected to treat water with reasonable quality (low to medium levels of color, turbidity and algae). In this process, the changes - particularly with regard to algae blooms - cause overload problems in the filters, since the particulate fraction must be removed at the filter media. It was identified therefore the need to seek alternative solutions to alleviate the burden of rapid filters. Several water supply systems operated by the Water and Sewerage Company of Ceará - CAGECE adopt the Ascending Direct Filtration (ADF) as treatment technology, a solution which at the time of its implementation was compatible with the characteristics of the raw water. Currently, due to eutrophication of water sources and the resulting blooms of many kinds of algae, systems work critically overloading filters and causing large water loss (the need for constant filters back washing) to meet quality standards set by legislation. The deployment of a unit placed before the existing filters to condition the raw water to the existing treatment stumbles on anoperational problem since much of the available studies adopts upflowfollowed by dowflowfilters which in the hydraulic point of view precludes the use of the existing structures. The unit of pre-treatment installed allowed the suitability of raw water with high presence of algae to the limitations of direct upflow filtration system, improving the quality of the water produced and reducing losses of treated water by the wash procedures. The pressure filter PFP1 (bed with Te = 2.4 and Cd = 1.2) operating at a filtration rate of 400 m3/m2.day showed a removal of 50% of apparent color and 65% of turbidity with a head loss remaining below 1 m.w.c. and a mean filtration runof 2.5 hours. The system of filters showedwater losses of 6.2%, smallerwhen compared to the upflow filter operating allone (16.2%) / O processo de tratamento por filtração direta costuma ser selecionado para o tratamento de água com qualidade razoável (baixos a médios teores de cor, turbidez e algas). Nesse processo, as mudanças de qualidade - particularmente no que tange à proliferação de algas - provocam problemas de sobrecarga nos filtros, uma vez que toda fração particulada deve ser removida nos meios filtrante. Identifica-se desta forma a necessidade de se buscar soluções alternativas para aliviar a sobrecarga dos filtros rápidos. Vários sistemas de abastecimento de água operados pela Companhia de Água e Esgoto do Ceará - CAGECE adotam a Filtração Direta Ascendente (FDA) como tecnologia de tratamento, solução que à época de sua implantação mostrou-se compatível com as características dos mananciais. Atualmente, devido à eutrofização dos mananciais e conseqüentes florações dos mais diversos tipos de algas, os sistemas trabalham de forma crítica com sobrecarga de filtros e grande perda de água (necessidade de constantes lavagens dos filtros) para atender aos padrões de qualidade definidos pela legislação. A implantação de uma unidade à montante dos filtros existentes para pré condicionar a água bruta e adequá-la ao tratamento existente é opção, mas esbarra em um problema de caráter operacional já que grande parte dos estudos disponíveis na literatura adota filtros ascendentes seguidos de descendentes, o que do ponto de vista hidráulico compromete o aproveitamento das estruturas existentes. A unidade de pré-tratamento possibilitou a adequação da água bruta com elevada presença de algas às limitações do sistema de filtração direta ascendente, melhorando a qualidade da água produzida e reduzindo as perdas de água tratada nas lavagens de filtros. O filtro de pressão PFP1 (leito com Te=2,4 e Cd=1,1) operando com uma taxa de filtração de 400 m3/m2.dia apresentou uma remoção de 50% de cor aparente e 65% de turbidez com perda de carga permanecendo abaixo de 1 m.c.a. ao longo de uma carreira de filtração média em torno de 2,5 horas. O sistema com filtro de pressão a montante do filtro ascendente apresentou ainda perdas com água de lavagem (6,2%) menores em comparação ao filtro ascendente operando isoladamente (16,2%).
98

Integração dos processos de eletroflotação e filtração granular descendente para o tratamento de água de produção de petróleo

Nonato, Thyara Campos Martins January 2017 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2017. / Made available in DSpace on 2017-07-04T04:03:47Z (GMT). No. of bitstreams: 1 346682.pdf: 3020190 bytes, checksum: cbda2a4f3af233416b319b831e62b800 (MD5) Previous issue date: 2017 / Um dos principais problemas enfrentado pela indústria petrolífera está relacionado à quantidade de água de produção gerada durante o processo de extração de petróleo e, consequentemente, a destinação final deste efluente, o qual deve passar por processos de tratamento visando atender as especificações para descarte nos oceanos ou injeção em poços de petróleo. Dessa forma, a presente pesquisa teve como objetivo avaliar a eficiência da integração dos processos de eletroflotação e filtração granular descendente no tratamento de água de produção de petróleo, utilizando para isso um efluente simulado preparado pela mistura de água de torneira, óleo lubrificante e NaCl. Para este fim, primeiramente foram estudados em sistema piloto, os efeitos das variáveis operacionais: taxa de escoamento do efluente, densidade de corrente elétrica e concentração de NaCl para a otimização do processo de eletroflotação e, posteriormente, foi estudada a integração dos processos. O desempenho do sistema piloto foi determinado por meio da redução do teor de óleos e graxas (TOG) do efluente tratado. De acordo com os resultados obtidos, o processo de eletroflotação teve o seu melhor desempenho com uma taxa de escoamento do efluente de 62,0 m3m-2d-1, densidade de corrente elétrica de 80,0 A m-2 e concentração de NaCl de 7900 mg L-1. Nessas condições, o processo de eletroflotação apresentou uma redução do TOG inicial (361,88 mg L-1) de mais de 94 % (20,15 mg L-1) após 180 min de eletrólise. Com a integração dos processos estudados, obteve-se uma redução média do TOG do efluente de mais de 98 % (6,42 mg L-1) ao longo de 12 h de tratamento, com um consumo energético do reator eletroquímico de 1,47 kWh m-3. Os processos integrados demonstraram ser também eficientes na redução de outros poluentes do efluente, além do TOG. Foram reduzidos 99,88 % de turbidez, 99,12 % de cor aparente, 90 % da absorbância no UV a 254 nm e 40 % de carbono orgânico dissolvido. Esses resultados demonstram a eficiência da integração dos processos de eletroflotação e filtração granular descendente na redução do TOG do efluente estudado a níveis aceitáveis pelo Conselho Nacional do Meio Ambiente (CONAMA) (< 29 mg L-1) e encorajam a aplicabilidade dessa tecnologia como um processo de tratamento para a indústria petroquímica.<br> / Abstract : One of the main problems faced by the oil industry is related to the amount of produced water generated during the oil extraction process and, consequently, the final destination of this effluent, which must undergo treatment processes in order to meet the specifications for disposal in the oceans or injection into oil wells. Thus, the present research had as objective to evaluate the efficiency of the integration of the processes of electroflotation and down-flow granular filtration in the treatment of water of petroleum production, using a simulated effluent prepared by the mixture of tap water, lubricating oil and NaCl. For this purpose, the effects of the operational variables: effluent flow rate, electric current density and NaCl concentration for the optimization of the electroflotation process were first studied in a pilot system, and the integration of the processes was studied later. The performance of the pilot system was determined by reducing the oils and grease content (OG) of the treated effluent. According to the results obtained, the electroflotation process had its best performance with an effluent flow rate of 62.0 m3m-2d-1, electric current density of 80.0 A m-2 and NaCl concentration of 7900 mg L-1. Under these conditions, the electroflotation process showed a reduction of the initial OG (361.88 mg L-1) of more than 94 % (20.15 mg L-1) after 180 min of electrolysis. With the integration of the studied processes, a mean reduction of the OG of the effluent of more than 98 % (6.42 mg L-1) was achieved over a 12 hour treatment, with an energy consumption of the electrochemical reactor of 1.47 kwh m-3. The integrated processes have also been shown to be efficient in reducing other effluent pollutants besides OG. 99.88 % turbidity, 99.12 % apparent color, 90 % UV absorbance at 254 nm and 40 % dissolved organic carbon was reduced. These results demonstrate the efficiency of the integration of the processes of electroflotation and descending granular filtration in reducing the OG of the studied effluent to levels acceptable to the national council of the environment (CONAMA) (< 29 mg L-1) and encourage the applicability of this technology as a process for the petrochemical industry.
99

Avaliação neurológica e da função cognitiva em pacientes com alto risco de embolização submetidos à cirurgia de troca valvar aórtica por estenose calcificada : papel do filtro intra-aórtico

Caputo, Paula Maria Santiago January 2013 (has links)
Introdução: Objetivo: Métodos: Resultados: Conclusão: Palavras Chave: As complicações neurológicas, principalmente de origem embólica, representam importante causa de morbi mortalidade em cirurgia cardiovascular. Estudos prévios demonstram que os filtros intra-aórticos são eficazes em capturar partículas oriundas da manipulação durante cirurgias cardíacas, porém seu benefício sobre desfechos neuro-cognitivos é controvertido. Avaliar o papel do filtro intra-aórtico Embol-X® na função neurológica e cognitiva de pacientes portadores de estenose aórtica ificada grave submetidos à cirurgia de troca valvar aórtica. Ensaio clínico randomizado de pacientes consecutivos ores de estenose aórtica calcificada grave submetidos à troca valvar aórtica(situação de alto risco para eventos embólicos) divididos em 2 grupos: com uso de filtro intra-aórtico (n=12) e sem o uso de filtro (n=15). Após sua retirada, os filtros foram fixados em formal a 10% e realizada análise histológico do material capturado. A avaliação neurológica foi realizada pela aplicação do questionário The European Stroke Scale (NIH) e a avaliação cognitiva pelo questionário Mini-Mental, ambos aplicados no período pré-operatório, no 6º dia de pós-operatório e 30 dias após a cirurgia. A população foi composta por pacientes com idade de 66±10 anos. O tempo médio de uso de circulação extra-corpórea foi 57±13 minutos e a média do tempo de clampeamento aórtico foi 43,2 ±11 minutos. Não houve diferença entre os grupos quanto à idade, sexo, nível de escolaridade ou extensã da doença aterosclerótica. Não ocorreram complicações relacionadas com o uso do dispositivo de proteção intraaórtico. Não ocorreu nenhum óbito ou evento neurológico maior no período intraoperatório, nem durante a avaliação em até 30 dias após a cirurgia. Partículas embólicas foram encontradas em 100% dos filtros, porém não se observou diferenças estatisticamente significativas em nenhuma das escalas avaliadas depois dos procedimentos cirúrgicos entre os grupos (todos valores de p > 0,10). Conclusão: O dispositivo de filtração intra-aórtico Embol-X® foi efetivo na captação de fragmentos durante a cirurgia valvar aórtica. Entretanto, seu papel na minimização de eventos neuro-cognitivos não foi evidenciado. Estudos com casuística maior serão necessários para demonstrar o potencial benefício clínico desta tecnologia.
100

Tratamento de água de chuva através de filtração lenta e desinfecção UV

Bastos, Fernanda Pereira 30 July 2007 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2016-05-18T19:28:17Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Fernanda Bastos.pdf: 2383262 bytes, checksum: 97593c61028106e6c41a5fb1222c092c (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-06-14T18:04:40Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Fernanda Bastos.pdf: 2383262 bytes, checksum: 97593c61028106e6c41a5fb1222c092c (MD5) / Made available in DSpace on 2016-06-14T18:04:40Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Fernanda Bastos.pdf: 2383262 bytes, checksum: 97593c61028106e6c41a5fb1222c092c (MD5) / Diante de problemas de escassez de água na atualidade, o uso de fontes alternativas de suprimento é citado como solução para a conservação de água. Dentre essas fontes destaca-se o aproveitamento de água de chuva, que se caracteriza por ser uma solução simples e barata para se preservar água potável. Dentro deste contexto, esta pesquisa promoveu uma caracterização da água da chuva, viabilizando um sistema de tratamento desta água que tenha menor demanda operacional possível e que contribua para melhorar a qualidade de vida de populações que não têm acesso à água potável, com o menor impacto possível ao meio ambiente. Este trabalho estabelece as diretrizes para a concepção e elaboração de um projeto de abastecimento de água, onde o tratamento será através de Filtros Lentos e desinfecção ultravioleta, uma vez que a cloração – método mais tradicional – demanda um custo operacional mais elevado e também é rejeitada por algumas comunidades, devido ao sabor conferido à água clorada. Para a captação da água da chuva utilizaram-se os telhados dos prédios localizados no Parque Experimental do Núcleo Água, que foram construídos com telha metálica e possuem área de projeção total de, aproximadamente, 180m². Anexo ao prédio construiu-se um sistema de armazenamento e tratamento da água da chuva, composto por dois filtros lentos verticais e lâmpadas ultravioleta. A caracterização foi realizada por meio de 12 análises físico-químicas semanais: temperatura, pH, turbidez, cor verdadeira, sólidos suspensos, dissolvidos e totais, acidez, alcalinidade, dureza, cloretos, sendo que as três primeiras eram realizadas diariamente. E por meio de análises microbiológicas, como: coliformes termotolerantes, coliformes totais e Escherichia coli. Foi analisada a água de chuva sem tratamento, após passagem pelos filtros lentos com diferentes taxas de filtração (4, 6 e 8 m3/m2.dia) e após passagem pela desinfecção UV, com intensidade média de 0,57 mW/cm2. A água de chuva analisada pode ser classificada de acordo com o CONAMA 357/05 como de classe 1 e de acordo com a NBR 12.216/92 como tipo B, sendo necessária em ambas classificações um tratamento para o consumo humano. A qualidade da água de chuva, após filtração lenta, em relação à Portaria 518/04, do Ministério da Saúde, foi, em geral, satisfatória, porém, é necessária desinfecção para ser considerada potável. A taxa de radiação UV aplicada apresentou boa eficiência na remoção dos microorganismos estudados, tornando-a própria para consumo humano. / In the face of water scarcity problems in the present time, the use of alternative supply sources is cited as solution for the water conservation. Among these sources, the main is the rainwater catchment system, characterized by a simple and cheap solution to preserve drinking waters. In this context, this research promoted a characterization of the rainwater, making it possible a system of treatment of this water making viable the smallest operational demand possible, and thus, contributes to improve the quality of life of populations that do not have access to drinking waters with low impact possible to the environment. The present work establish the guidelines for the conception and elaboration of a project of water supply, where the treatment will be through Slow Filters and ultraviolet disinfection – keeping in mind that the chlorination, conventional method, demand a operational high cost, and also is rejected by some communities, because of the taste of the chlorinated water. The roofs of the building located in the “Parque Experimental do Núcleo Água” were utilized for the rainwater capitation, were constructed with metallic tile and, approximately, 180m ² of total projection area. Annex to the building was constructed a system of storage and treatment of the rainwater, is formed by two vertical slow filters and ultraviolet light bulbs. The characterization occurred through by 12 weekly physical-chemical analyses: temperature, pH, turbidity, true color, suspended solids, dissolved solids and total solids, acidity, alkalinity, hardness, chloride -the first three were carried out every day; and microbiological analyses, like: thermo tolerant and total coliforms and Escherichia coli. The rainwater was analyzed without treatment after passage through the slow filters with different filtration rates (4, 6 e 8 m3/m2 day), and after passage through ultraviolet disinfection with average of the 0,57 mW/cm2 . The rainwater analyzed can be classified according to CONAMA 357/05 is class 1 and according to NBR 12.216/92 is type B, being necessary in both classifications a treatment for the consumption. The quality of rainwater, after slow filtration, regarding Brazilian Ministry of Health Directive # 518/04, was, in general satisfactory, but is necessary the disinfection to be considered drinking water. The rate of ultraviolet radiation applied showed good efficacy for removal of microbiological studied in this research, being suitable for drinking.

Page generated in 0.2066 seconds