• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 418
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 435
  • 211
  • 109
  • 105
  • 104
  • 88
  • 84
  • 78
  • 71
  • 65
  • 61
  • 52
  • 51
  • 40
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

O mexilhão dourado Limnoperna fortunei (Dunker, 1857) na presença de cianobactérias : taxas de filtração, comportamento alimentar e sobrevivência

Paulo, Vanessa Gazulha January 2010 (has links)
O objetivo deste estudo foi avaliar o comportamento alimentar e a sobrevivência do bivalve invasor Limnoperna fortunei, conhecido como mexilhão dourado, na presença de cianobactérias tóxicas e não-tóxicas. O presente estudo é o primeiro a avaliar os efeitos de cianobactérias tóxicas na alimentação e sobrevivência de L. fortunei, e o primeiro a estimar as taxas de filtração das larvas de L. fortunei. Primeiro, foi testada a hipótese de que L. fortunei ingere preferencialmente fitoplâncton não-tóxico e rejeita cianobactérias tóxicas, e que as toxinas de cianobactérias têm um efeito negativo na sobrevivência do mexilhão. Em segundo lugar, foi testada a hipótese de que L. fortunei filtra com mais eficiência as partículas menores, como as células solitárias, do que as partículas maiores, como as cianobactérias coloniais e filamentosas. Em terceiro lugar, foi testada a hipótese de que as toxinas de cianobactérias afetam negativamente a alimentação e sobrevivência das larvas de L. fortunei. As taxas de filtração mais elevadas foram registradas quando os mexilhões foram alimentados com o fitoplâncton não-tóxico Nitzschia. Apesar disso, o mexilhão dourado expeliu células de Nitzschia em grandes quantidades e ingeriu, preferencialmente, células de Microcystis, tanto tóxicas, quanto não-tóxicas. Os mexilhões foram expostos a cepas tóxicas e não-tóxicas de Microcystis durante 5 dias, e não foram registrados efeitos tóxicos na sua alimentação e sobrevivência. Os resultados demonstraram que a toxicidade das cianobactérias não é o principal factor que influencia o comportamento alimentar de L. fortunei. As taxas de filtração do mexilhão dourado na presença de cianobactérias solitárias, coloniais e filamentosas mostraram que as células solitárias foram preferencialmente aceitas como alimento, enquanto os filamentos e colônias foram massivamente expelidos como pseudofeces. A sobrevivência das larvas de L. fortunei foi elevada na presença de algas verdes e seston natural durante todo o experimento. Após quatro dias de exposição, a sobrevivência das larvas diminuiu na presença das cianobactérias. A baixa sobrevivência das larvas observada em todos os tratamentos contendo cianobactérias, até mesmo as cepas não tóxicas, pode ter sido influenciada pela toxicidade e também pela qualidade das cianobactérias. A baixa concentração de lipídeos nas cianobactérias pode ter causado uma deficiência nutricional nas larvas. As larvas ingeriram as algas verdes Monoraphidium, assim como cepas tóxicas e não-tóxicas de Microcystis a taxas de filtração similares. Estes resultados indicam que as toxinas de cianobactérias não tiveram nenhum efeito sobre a atividade de filtração de L. fortunei, possivelmente relacionado com a incapacidade das larvas de detectar a toxicidade do alimento. A sobrevivência dos adultos de L. fortunei na presença de cianobactérias tóxicas indica o potencial deste bivalve invasor como um vetor para a transferência de cianotoxinas para os níveis tróficos superiores. As densidades massivas de L. fortunei em associação com sua elevada capacidade de filtrar evidenciam o potencial desta espécie invasora para promover grandes alterações na estrutura das cadeias tróficas dos ecossistemas invadidos. / The aim of this study was to evaluate feeding behavior and survival of the invasive bivalve Limnoperna fortunei, socalled golden mussel, in the presence of toxic and non-toxic cyanobacteria. The present study is the first to evaluate the effects of toxic cyanobacteria on feeding and survival of L. fortunei, and the first to estimate filtration rates of L. fortunei larvae. First, it was tested the hypothesis that L. fortunei preferentially graze on non-toxic phytoplankton and reject toxic cyanobacteria, and that cyanobacteria toxins have a negative effect on mussel survival. Second, it was tested the hypothesis that L. fortunei filter more efficiently smaller particles, such as single-celled, than larger particles, such as colonial and filamentous cyanobacteria. Third, it was tested the hypothesis that cyanobacteria toxins negatively affect feeding and survival of L. fortunei larvae. Highest filtration rates were registered when mussels fed on non-toxic phytoplankton Nitzschia. Despite that, golden mussel expelled Nitzschia cells in large quantities and preferentially ingested Microcystis cells, both toxic and non-toxic strains. Mussels were exposed to toxic and non-toxic strains of Microcystis during 5 days and no toxic effects were registered on their feeding and survival. Results have demonstrated cyanobacteria toxicity is not the main factor influencing L. fortunei feeding behavior. Filtration rates of golden mussel in the presence of single-celled, colonial, and filamentous cyanobacteria have demonstrated that single cells were widely accepted as food, while filaments and colonies were massively expelled as pseudofeces. L. fortunei larvae survival was high in the presence of green algae and natural seston during all experiment. After four days of exposure, larvae survival decreased in the presence of cyanobacteria. Low larvae survival observed in all cyanobacteria treatments, including the non-toxic, might have been influenced by cyanobacteria toxicity and also by quality. Low lipid concentration of cyanobacteria may have caused a nutritional deficiency to larvae. Golden mussel larvae ingested Monoraphidium as well as non-toxic and toxic Microcystis at similar filtration rates. It indicates cyanobacteria toxins had no effect on filtration activity of L. fortunei possibly relating to larvae incapability to detect food toxicity. Survival of L. fortunei adults in the presence of toxic cyanobacteria shows the potential of this invasive bivalve as a vector for the transference of cyanotoxins to higher trophic levels. Massive densities of L. fortunei in association to its powerful filtering capability point out to the potential of this invasive species to promote great changes in the structure of trophic chains from invaded ecosystems.
122

Avaliação da medida da cistatina C e das equações do estudo MDRD para estimar a taxa de filtração glomerular em indivíduos normais

Prates, Aline Bodanese January 2005 (has links)
A avaliação acurada da função renal através da medida da taxa de filtração glomerular (TFG) é fundamental na rotina clínica, pois é parte decisiva do diagnóstico e terapêutica. A recomendação atual da National Kidney Foundation (NKF) é o uso de equações que incluam a creatinina, idade, gênero e raça. No entanto a acurácia dessas equações tem sido questionada. Desta forma, investigadores ainda buscam um marcador ideal para analisar a função renal. Neste contexto, se encaixam os estudos com a cistatina C, uma substância endógena, que tem sido relatada como um indicador confiável e de fácil execução para esse propósito. A presente dissertação considerou a dosagem de cistatina C e a utilização da equação do MDRD para a avaliação da função renal em indivíduos saudáveis.
123

Biologia reprodutiva e efeitos do Tributilestanho (TBT) sobre Mytella charruana e Mytilopis leucophaeta (Bivalvia- Mollusca) do estuário do Rio Capibaribe, Pernambuco

Claudino Maciel, Daniele 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T15:07:02Z (GMT). No. of bitstreams: 2 arquivo3004_1.pdf: 3600988 bytes, checksum: 866861a6f227f56baa88f4b5126f8290 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O tributilestanho é um biocida extremamente tóxico, utilizado para proteger os cascos de embarcações de incrustações de invertebrados. O objetivo deste trabalho foi avaliar os efeitos deste composto sobre M. charruana e M. leucophaeta, e descrever o ciclo reprodutivo destas espécies, que foi avaliado de Setembro de 2009 a Setembro de 2010. Para a realização dos ensaios e determinação do ciclo reprodutivo, os animais foram coletados em dois pontos do estuário do Rio Capibaribe. Para M. leucophaeta foram identificados dois períodos de intensa atividade gametogênica, entre dezembro de 2009 e janeiro de 2010, e em março de 2010; e dois períodos de desova, de setembro a novembro de 2009, e em agosto de 2010. Para M. charruana a desova ocorreu em praticamente todos os meses, com destaque para abril e agosto de 2010. O ciclo reprodutivo de ambas as espécies demonstrou ser contínuo e assincrônico. Para avaliar a toxicidade aguda do TBT sobre M. charruana e M. leucophaeta, indivíduos das duas espécies foram expostos por 96h a concentrações de 2, 5, 12,5 e 50 &#956;g.L-1 de cloreto de tributilestanho TBTCl. Observou-se mortalidade de 100% dos indivíduos de M. charruana expostos a concentração de 12,5 &#956;g.L-1 enquanto que para M. leucophaeta houve mortalidade de 100% dos indivíduos expostos a 50 &#956;g.L-1. A proporção de indivíduos de ambas as espécies com valvas fechadas aumentou significativamente com o aumento da concentração de cloreto de tributilestanho (TBTCl) (p<0,05). Os resultados indicam que M. charruana é mais sensível à exposição ao TBT que a espécie exótica M. leucophaeta, o que pode ser relevante para o sucesso da colonização do invasor. Para avaliar a toxicidade crônica do TBT sobre M. leucophaeta, indivíduos foram expostos por 14 dias a concentrações de 1, 5 e 10 &#956;g.L-1. A mortalidade foi menor do que 20% até 5 &#956;g.L-1, atingindo 73,3% no tratamento com 10 &#956;g.L-1. A taxa de filtração nos controles foi maior que nos tratamentos com TBTCl (F(4, 15)=57,3; p< 0,0001). A proporção de indivíduos com valvas fechadas foi maior no tratamento com 10 &#956;g.L-1 (p< 0,0001). Os resultados sugerem que em um maior período de exposição a concentrações mais baixas, os indivíduos encerram suas valvas diminuindo consequentemente a taxa de filtração. Ambas as espécies apresentaram respostas ecologicamente relevantes à exposição ao TBT, podendo ser utilizadas no monitoramento da poluição por este composto no ambiente
124

Tecnologia alternativa em drenagem urbana: telhado verde

SILVA, Thomas Fernandes da 07 August 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-23T19:30:12Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-29T22:11:43Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) / Made available in DSpace on 2018-08-29T22:11:43Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇAO Thomas da Silva.pdf: 2014903 bytes, checksum: c8f0869d10c67e0e427081c3096c4ec5 (MD5) Previous issue date: 2017-08-07 / FACEPE / A urbanização de forma desordenada das cidades brasileiras proporciona a redução das áreas verdes e o aumento das áreas impermeáveis, favorecendo o aumento na velocidade do escoamento superficial, fazendo com que a água seja deslocada do ambiente o mais rápido possível, gerando áreas de inundação a jusante. As novas alternativas propostas para resolver problemas de drenagem urbana buscam, de uma forma eficiente, trata-los o mais próximo possível da fonte. Uma alternativa, natural e sustentável é a implantação dos telhados verdes, que se caracteriza pela aplicação de vegetação sobre a cobertura de edificações com impermeabilização e drenagem adequadas. Este trabalho tem a finalidade de investigar a funcionalidade de um telhado verde instalado no IPA no município de Caruaru, com relação a sua capacidade de retenção da vazão da água pluvial escoada, e avaliar o tratamento do efluente do telhado verde pelo sistema de filtração descendente em areia. Utilizou-se vegetação típica de regiões semiáridas, Babosa (Aloe Vera) e Coroa-de-Frade (Melocactus Zehntneri), e comparou-se ao telhado convencional. Após o uso de simulador de chuva, analisou-se a capacidade de retenção do telhado através do balanço hídrico no sistema. Foram realizados ensaios de bancada para avaliar a eficiência de duas configurações de filtro de areia, com diferentes granulometrias, em relação ao melhoramento da qualidade do efluente dos telhados verdes e do efluente sintético, desenvolvido em laboratório. Os telhados verdes apresentaram boa capacidade de retenção, chegando a valores de 75% e 86%, para os telhados verdes Babosa e Coroa-de-Frade, respectivamente. Observou-se um retardo na ocorrência do pico de vazão de até 14 minutos no telhado verde Babosa em relação ao telhado Convencional (telha cerâmica) e um retardo de até 21 minutos no telhado verde Coroa-de-Frade em relação ao telhado Convencional (telha cerâmica). Sendo a vegetação Coroa-de-Frade uma boa possibilidade de uso para este fim em regiões semiáridas. O desempenho do filtro foi analisado, através dos parâmetros de qualidade da água para irrigação, condutividade elétrica, sólidos dissolvidos totais, cálcio, magnésio, sódio, carbonatos, bicarbonatos, cloretos, sulfatos, nitrogênio–nitrato, nitrogênio amoniacal, fósforo–fosfato, potássio, boro, acidez ou alcalinidade e razão de adsorção de sódio. Conforme as análises observou-se que o filtro de areia apresentou-se como uma alternativa para o tratamento do efluente gerado pelo telhado verde em estudo. / The urbanization in a disorderly way of the Brazilian cities causes the reduction of green areas and the increase of impermeable areas, favoring the increase in the speed of the surface runoff, causing the water to be displaced from the environment as quickly as possible, generating flood areas downstream. The new alternatives proposed to solve problems of urban drainage seek, in an efficient way, treat them as close as possible to the source. An alternative, natural and sustainable is the implementation of green roofs, which is characterized by the application of vegetation on the roof of buildings with adequate waterproofing and drainage. This work has the purpose of investigating the functionality of a green roof installed in the IPA in the city of Caruaru, in relation to its capacity of retention of the flow of the drained pluvial water, and to evaluate the treatment of the effluent of the green roof by the system of descending filtration in sand. Typical vegetation of semi-arid regions, Babosa (Aloe Vera) and Coroa-de-Frade (Melocactus Zehntneri) was used, and compared to the conventional roof. After the use of rainfall simulator, the retention capacity of the roof was analyzed through the water balance in the system. Bench tests were carried out to evaluate the efficiency of two sand filter configurations, with different particle sizes, in relation to the improvement of the quality of green roofs and synthetic effluent, developed in the laboratory. The green roofs showed good retention capacity, reaching values of 75% and 86%, for the green roofs of Babosa and Coroa de Frade, respectively. There was a delay in the occurrence of the peak flow of up to 14 minutes on the roof of the Babosa green roof compared to the conventional roof (ceramic tile) and a delay of up to 21 minutes on the roof green Crown of Frade in relation to the conventional Roof Ceramics). Since the Coroa-de-Frade vegetation is a good possibility of use for this purpose in semi-arid regions. The performance of the filter was analyzed through water quality parameters for irrigation, Electric Conductivity, Total Dissolved Solids, Calcium, Magnesium, Sodium, Carbonates, Bicarbonates, Chlorides, Sulphates, Nitrogen-Nitrate, Ammoniacal Nitrogen, Phosphorus-Phosphate, Potassium, Boron, Acidity or Alkalinity and Sodium Adsorption Ratio. According to the analyzes, it was observed that the sand filter was may be considered as an alternative for the treatment of the effluent generated by the green roof under study.
125

Influência da temperatura e da pressão sobre a permeação de gases (CO2/CH4) através de membranas poliméricas assimétricas de PVDF e PSF

Biondo, Lucas David 14 July 2014 (has links)
Atualmente, existe no mundo a necessidade de buscar alternativas aos combustíveis fósseis por fontes renováveis para a produção de energia. O gás natural possui vantagens significativas em relação a outros combustíveis fósseis, em especial pela redução nas emissões atmosféricas provenientes da sua combustão. O uso do metano presente no biogás é uma alternativa renovável ao uso do gás natural nas suas diversas aplicações, incluindo gás natural veicular. Para separação de metano, membranas têm recebido grande atenção devido às diversas vantagens, tais como eficiência energética na operação e baixo impacto ambiental com relação à outras tecnologias. Membranas poliméricas de poli (fluoreto de vinilideno) (PVDF) e polissulfona (PSf) foram sintetizadas através do método de inversão de fases. A realização de ensaios de permeação sob uma faixa de pressão de operação entre 2 e 5 bar, e sob uma faixa de temperatura de operação entre 20 e 45°C, e a análise da morfologia das membranas através de microscopia eletrônica de varredura em amostras das membranas, permitiram que fossem identificados os mecanismos de transporte atuantes nas membranas poliméricas. Os mecanismos de transporte contribuíram para a investigação e o entendimento da influência dos parâmetros de operação (temperatura e pressão) sobre a permeabilidade e a seletividade na separação de gases (CO2/CH4) nas membranas poliméricas. As membranas de poli (fluoreto de vinilideno) (PVDF) apresentaram elevada permeabilidade para ambos os gases em todas as pressões (2 a 5 bar) e temperaturas (20 a 45°C) estudadas, porém não se mostraram atraentes para esta aplicação devido à baixa seletividade na separação de gases, enquanto que as membranas de polissulfona (PSf) demonstraram boas perspectivas para esta aplicação, devido a uma melhor relação entre permeabilidade e seletividade. O incremento da pressão dentro da faixa estudada (2 a 5 bar) resultou em menores fluxos de permeado para o gás CO2, e fluxos de permeado constantes e por vezes maiores para o gás CH4. O incremento da temperatura aumentou o fluxo de permeado de ambos os gases. / Currently, there is a need in the world to substitute fossil fuels for renewable sources in the energy production. Natural gas has significant advantages over other fossil fuels, in particular the reduction in atmospheric emissions from their combustion. The use of methane, present in biogas, is a renewable alternative instead of using natural gas in its various applications, including as an alternative energy for vehicles. Within this context, polymeric membranes have received great attention due to several advantages, such as energy efficiency in operation and low environmental impact regarding to other technologies. Polymeric Membranes of poly (vinylidene fluoride) (PVDF) and polysulfone (PSf) were synthesized by the phase inversion method. Permeation testing under a range of operating pressure between 2 and 5 bar, and under a range of operating temperature between 20 and 45 °C, together with morphology analysis by scanning electron microscopy, allowed to identify the transport mechanism acting in the polymeric membranes. The transport mechanisms contributed to investigate and understand the influence of operating parameters (temperature and pressure) on permeability and selectivity in gas separation (CO2/CH4) in the polymeric membranes. The membranes of poly (vinylidene fluoride) (PVDF) showed high permeability to both gases at all pressures (2 to 5 bar) and temperatures (20 to 45 °C) studied,, however, not attractive for this application due to low selectivity in gas separation, while the membranes of polysulfone (PSf) showed good prospects for this application, due to a better relationship between permeability and selectivity. Increasing pressure within the studied range (2 to 5 bars) resulted in lower permeate fluxes for CO2 and permeate flows constant and occasionally higher for CH4. The increase in temperature increased the permeate flux of both gases.
126

Efeito das características granulométricas e da altura da camada filtrante no processo de retrolavagem em filtros de areia / Effect of grain size and depth bed filtering characteristics in the backwash process of sand filters

Salcedo Ramirez, Juan Camilo 12 July 2010 (has links)
Orientador: Roberto Testezlaf / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-17T14:05:19Z (GMT). No. of bitstreams: 1 SalcedoRamirez_JuanCamilo_M.pdf: 5267423 bytes, checksum: 8280ac47eb6e5c177b8a4533cedd1d53 (MD5) Previous issue date: 2010 / Resumo: O desempenho adequado de filtros de areia na irrigação localizada requer que os processos de filtração e retrolavagem sejam realizados de forma a reter as partículas em suspensão indesejadas e que a lavagem do meio filtrante retorne a operação do equipamento às suas condições originais de limpeza. A retrolavagem pode ser mais eficiente quando se atinge expansões homogêneas da camada com baixas perdas de pressão em função das características granulométricas da areia e da altura da camada filtrante. As faltas de experiência do produtor e de informações técnicas dos fabricantes determinam que a retrolavagem não seja realizada corretamente em campo, prejudicando a funcionalidade e eficiência dos filtros de areia. Neste contexto, o objetivo do presente trabalho foi desenvolver estudos sobre o comportamento das características hidrodinâmicas de pressão e vazão no processo da retrolavagem em filtros com variações nas características físicas da areia e nos componentes internos dos filtros. O trabalho foi dividido em três partes. Inicialmente, foi realizada, uma pesquisa de campo sobre os procedimentos e manejos utilizados pelos agricultores na execução da retrolavagem. Em uma segunda etapa, foi utilizada uma metodologia experimental para ensaios de laboratório em três filtros de areia convencionalmente usados no mercado brasileiro, para avaliar os efeitos de diferentes granulometrias da areia e diferentes alturas da camada filtrante sobre a perda de carga ao longo da camada e sobre o processo de fluidização do leito. Finalmente, na ultima parte, os resultados obtidos foram comparados com comportamento teóricos para estimativa da velocidade mínima de fluidização. Os procedimentos realizados pelos produtores demonstraram falta de conhecimento no processo da retrolavagem que é executado de forma empírica baseado em recomendações incorretas dos fornecedores. Experimentalmente, obteve-se que o processo de retrolavagem é afetado significativamente pela perda de pressão causada pelos componentes estruturais internos do filtro (crepina e difusor). As comparações dos resultados calculados a partir da equação de WEN & YU (1966) com os resultados experimentais, revelaram concordâncias explicitas para as granulometrias menores. A pesquisa permitiu concluir que a vazão da retrolavagem necessária para a expansão adequada do leito, aumenta proporcionalmente com as condições da altura da camada e da granulometria da areia / Abstract: The adequate sand filters performance in localized irrigation requires that filtration and backwash processes are capable to retain unwanted suspension particles and to wash properly the media depth, returning the equipment operation to its original condition of cleanliness. The backwash process can be more effective when it reaches bed uniform expansions with low head losses, which depends on the grain size and the depth of media bed. The lack of experience of farmers and technical information from the manufacturers determine that the backwash process has been performed incorrectly in the field, affecting adversely the functionality and efficiency of the sand filters. In this context, the objective of this study was to develop studies on the hydrodynamic behavior of the relationship of working pressure and flow rate in the backwash process of sand filters with variations in sand physical characteristics and the internal hydraulic components of the filters. This study was divided into three parts. Initially, a field survey on the farmers backwash procedures and management was performed. In a second step, an experimental methodology was developed to evaluate three commercial types of Brazilian sand filters to assess the effects of different grains diameters and media layer depths on the head losses and the process of layer fluidization. Finally, the experimental results of the minimum fluidization velocity were compared with estimated values using the theoretical behavior of the process. The results showed that the procedures performed by the producers showed a lack of knowledge in the backwash process, which is executed based on empirical basis, oriented by imprecise information of suppliers. The experimental part demonstrated that the backwash process is affected significantly by the head loss originated from the internal structural components of the filter (underdrain and diffuser). The mathematical comparisons of the experimental results with the values estimated by the equation & WEN YU (1966) showed explicit agreements for smaller particle size. The research allowed concluding that the values backwash flow rate required for an adequate expansion, increases proportionally with the depth and the particle size of sand layer / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
127

Estudo da liga de aluminio-zinco como filtração alternativa para a radiação X

Haiter, Claudia 15 December 2000 (has links)
Orientação: Frab Norberto Boscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T14:26:03Z (GMT). No. of bitstreams: 1 Haiter_Claudia_M.pdf: 3563481 bytes, checksum: 0f8631489485e0a3818bb5e6539a19e8 (MD5) Previous issue date: 2000 / Resumo: O objetivo deste trabalho foi avaliar os efeitos da filtração alternativa da liga alumínio/zinco em aparelhos de raios X odontológicos, em relação ao espectro de energia dos feixes de raios X, a taxa de kerma no ar, o índice de contraste nas radiografias obtidas e qualidade das imagens radiográficas. Este estudo foi realizado comparando o filtro convencional de alumínio com várias espessuras do filtro de liga alumínio/zinco, em diferentes porcentagens do elemento zinco na liga (2%, 3%, 4% e 5%). Foi utilizado um aparelho de raios X odontológico convencional, operando com 60 kVp e 70 kVp, e filmes radiográficos pertencentes ao grupo D e E de sensibilidade. Foram realizadas radiografias de um "phantom" e de uma escala de densidade de alumínio. O uso dos filtros de liga AI/Zn resultou em um não endurecimento dos feixes. A taxa de kerma no ar diminuiu em até 18,53%, sem alteração no contraste das radiografias. A qualidade das imagens obtidas com os filtros de liga AIZn também tiveram uma boa aceitação pelos examinadores. A análise dos resultados nos levou a concluir que o filtro de liga AIZn 2%, com 1,99 mm de espessura, tensão de 60 kVp, quando usado com filme D, foi o que obteve melhor desempenho, reduzindo a taxa de kerma no ar sem variar o índice de contraste das radiografias, mantendo a qualidade da imagem aceitável para diagnóstico, sem contudo aumentar o tempo de exposição / Abstract: The aim of this research was evaluate the effects of the alternative filtration of the aluminumlzinc alloy in dental X rays machines, in relation to the spectrum of energy , the X ray dose, the contrast alterations and the image quality. This study was accomplished comparing the conventional aluminum filter with several thickness of the aluminumlzinc alloy filter, in different percentages of zinc in the alloy (2%, 3%, 4% and 5%). It was used a conventional X ray machine, operating with 60 kVp and 70 kVp, and D and E speed films, in order to obtain images of a phantom and of a aluminum step wedge. The use of the filters Al/Zn resulted in a spectra with smaller amount of fótons, however it was not found hardening of the beam. The kerma in the air was decreased in up to 18,53%, without alteration in the contrast of the images. The quality of the images obtained with the filters Al/Zn also had a good acceptance for the examiners. The analysis of the results showed that the filter alloy Al/Zn 2%, with 1,99 mm of thickness, tension of 60 kVp, when used with film D, obtained the best performance, reducing the kerma in the air without reducing contrast, and the image quality was considered acceptable for diagnosis. This filter also didn't needed an increase in the exposition time that would cause an consequent increase in the load of the tube / Mestrado / Mestre em Radiologia Odontológica
128

Desenvolvimento de Instalação de filtração com carvão ativado impregnado com prata para a melhoria da qualidade da água de consumo humano / Development of a activated carbon supporting silver installation for the improvement of water quality for human consumption

Rogério Pecci Filho 18 May 2000 (has links)
Tendo em vista a existência de muitas comunidades no Estado de São Paulo (e em outros estados do Brasil), que utilizam água muitas vezes com qualidade imprópria ao consumo humano, o presente trabalho visa o desenvolvimento de uma instalação de filtração utilizando Carvão Ativado Impregnado com Prata (CAIP) com o intuito de eliminar alguma contaminação na água tratada devido à problemas tais como anomalias operacionais na ETA, tecnologia de tratamento inadequada, contaminação da rede de distribuição, reservação, dentre outros. Para a investigação experimental foram preparados três tipos de água de estudo, com baixos valores de turbidez e cor aparente. A água tipo I era isenta de contaminação, as águas tipo II e III apresentaram coliformes totais e fecais, sendo que a água tipo III utilizada na simulação da instalação como filtro domiciliar. Os ensaios realizados apresentaram taxa de filtração entre 200 e 250 m3/m2*d. Os resultados indicam que o CAIP apresentou propriedades adsorventes e é um poderoso agente desinfetante, reduzindo significativamente o NMP de coliformes totais e fecais de águas contaminadas. Porém, a desinfecção não foi completa e ocorreu excessivo desprendimento da prata do CAIP, inviabilizando o uso deste CAIP nesta instalação desenvolvida. / Minding the existence of many communities within the state of São Paulo (and other Brazilian states) which often use water unfit for human consumption, this work aims at the development of a filtering installation that uses Activated Carbon supporting Silver (AC(Ag)) in an attempt to eliminate any contamination in treated water. Such water contamination problems include, operational anomalies in the WTP, inadequate treatment technologies, contamination in the distribution net, and other filter specific problems. For the experimental investigation three types of test water were prepared, with low turbidity and apparent color values. Water type I was contarnination-free, water type II and III had total and fecal coliforms, and water type III was used in the simulation of domestic filtering installation. Tests showed a filtering rate between 200 and 250 m3/m2*d. Results point that AC(Ag) has adsorbent capabilities, in addition to being a powerful disinfection agent, and reduced significantly the number of total and fecal coliforms of contaminated waters. However, disinfection was not thoroughly, and silver was excessively dragged away, from the Activated Carbon, thus rendering the use of AC(Ag) unadvisable in the developed installation.
129

Adaptação e selamento apical da obturação com cones de guta-percha de diferentes conicidades após duas técnicas de instrumentação / Adaptation and apical sealing of obturation with gutta-percha after two tapers of different instrumentation techniques

Nicastro, Karine Schell de Moraes 19 August 2018 (has links)
Orientadores: José Flávio Affonso de Almeida, Caio Cezar Randi Ferraz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T18:53:10Z (GMT). No. of bitstreams: 1 Nicastro_KarineSchelldeMoraes_M.pdf: 1993293 bytes, checksum: 8a68234b96ec379b86f37b8d3aa3f18b (MD5) Previous issue date: 2012 / Resumo: O objetivo desse estudo foi avaliar o preenchimento e selamento apical da obturação com cones de guta-percha de diferentes conicidades, após o preparo químico-mecânico com batente apical e preparo cônico contínuo. Foram utilizadas 90 raízes mesiais de molares inferiores com dois canais e forames distintos. As raízes foram divididas em seis grupos de acordo com o preparo apical: Grupos 1, 2 e 3 - preparo com batente apical e nos Grupos 4, 5 e 6 - preparo cônico contínuo. Todos os grupos foram instrumentados com o sistema rotatório K3. A obturação foi feita com a Técnica Onda Contínua de Condensação, utilizando três tipos de cones de guta-percha não estandartizados: Fine, Fine-Medium e Medium. Analisou-se a micro infiltração apical, através da Filtração de Fluidos, em apenas um dos canais da raiz mesial utilizando o Flodec. Verificou-se o preenchimento dos cones de guta-percha no interior do canal à 1,5, 2,5 e 3,5 mm do forame apical, utilizando a lupa estereoscópica com aumento de 20x. Foram comparados em cada corte a área de guta-percha obturada em relação à área instrumentada; à área total do canal radicular e à área de falhas presentes nas obturações. Para microinfiltração apical não houve diferença estatística entre os grupos testados. Quando analisada a área ocupada pela guta-percha em relação à área instrumentada, à área total e à área de falhas entre os diferentes cortes (1,5, 2,5 e 3,5) no mesmo grupo em ambos os preparos não houve diferença estatística. Em contraposição quando foi considerado à área instrumentada, no grupo 5 houve diferença estatística comparando os cortes 1,5 e 2,5mm. Para área total, no grupo 2, obteve-se diferença nos cortes a 1,5 e 2,5mm. Quando se considerou o mesmo corte (1,5, 2,5 e 3,5) para os diferentes grupos, particularmente para área instrumentada, o Grupo 5 apresentou melhores resultados que o Grupo 4 no corte à 1,5mm. Para a área total, nível de corte 1,5mm, o Grupo 5 apresentou melhor adaptação da guta-percha do que o Grupo 6. Os cones de diferentes conicidades demonstraram adaptações semelhantes tanto no preparo com batente apical tanto no preparo cônico contínuo. A presença ou ausência do batente apical, a conicidade e adaptação dos cones de guta-percha e o diâmetro do forame apical não influenciaram o selamento apical da obturação / Abstract: The aim of this study was to evaluate the adaptation and apical sealing of the root canal filling with gutta-percha using different tapers with an apical stop or continuous preparation technique. Ninety mesial roots of mandibular molars with two canals ending in distinct forame were used. The roots were divided into six groups according to instrumentation technique: Groups 1, 2 and 3 - using apical stop; and groups 4, 5 and 6 - performed with the Continuous Preparation. Root canal preparation was performed with K3 rotary file system. The continuous wave technique of condensation was used for root canal filling, using three different tapered gutta-percha: Fine, Fine-Medium and Medium. First, apical microleakage was tested by fluid filtration in one of the mesial root canals. Secondly, the adaptation of gutta-percha was investigated at the 1.5, 2.5 and 3.5 mm from the apical foramen using stereomicroscope with 20x. The sections were compared considering area filled with gutta-percha, in relation to the instrumented area, the total area of the root canal and the area of gaps present in root fillings. Apical microleakage showed no statistical difference among the groups tested. When analyzing the area occupied by gutta-percha to instrumented area, total area and area of gaps among the different sections (1.5, 2.5 and 3.5) in the same group in both preparations there was no difference statistical. In contrast when it was considered in the instrumented area in Group 5, no statistical difference comparing the sections 1.5 and 2.5 mm. For the total area, in group 2, we obtained difference in the sections at 1.5 and 2.5 mm. When we considered the same section (1.5, 2.5 and 3.5) for the different groups, particularly for field instruments, the group 5 showed better results than in Group 4 cut to 1.5 mm. For the total area, 1.5 mm section level, the Group 5 showed better adaptation of gutta-percha than Group 6. The cones of different taper showed similar adaptions in both apical stop preparation and continuous tapered preparation. The presence or absence of the apical stop, taper and adaptation of gutta-percha and the diameter of apical foramen did not affect the apical seal the filling / Mestrado / Endodontia / Mestre em Clínica Odontológica
130

Efeito da cloração, uso de filtro de disco e de filtro de manta sintetica não tecida na obstrução de gotejadores

Ribeiro, Tulio Assunção Pires 03 August 2018 (has links)
Orientador: Jose Euclides Stipp Paterniani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-03T16:55:35Z (GMT). No. of bitstreams: 1 Ribeiro_TulioAssuncaoPires_D.pdf: 5122278 bytes, checksum: 04ef3ae647478c39bd20e5053ee03a7f (MD5) Previous issue date: 2003 / Doutorado

Page generated in 0.0682 seconds