• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 862
  • 15
  • 9
  • 8
  • 8
  • 8
  • 6
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 888
  • 550
  • 358
  • 160
  • 158
  • 157
  • 155
  • 125
  • 122
  • 114
  • 111
  • 106
  • 100
  • 90
  • 87
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Procedimento de avaliação de integridade estrutural de juntas soldadas circunferenciais em tubulações submarinas rígidas submetidas à flexão. / Fracture assessment procedure of pipe girth welds subjected to bending load.

Souza, Rodolfo Figueira de 11 April 2016 (has links)
A demanda crescente por energia tem motivado a procura por petróleo e gás natural em ambientes com condições extremas, como operações em águas profundas e o transporte de fluídos corrosivos. Avanços tecnológicos recentes favorecem o uso de tubos de aço contendo uma camada interna resistente a corrosão (comumente chamados de Lined ou Clad Pipes) para o transporte de tais fluidos agressivos. Além disso, as tubulações submarinas são sujeitas a condições de instalação muito severas e, um caso de interesse, é o procedimento de reeling que permite com que a fabricação e inspeção da tubulação seja feita em terra. Apesar de possuir vantagens econômicas, a avaliação da integridade estrutural e especificação dos tamanhos toleráveis de trinca em juntas soldadas, nestas condições, torna-se uma tarefa complexa, devido a natureza dissimilar dos materiais e ao grande nível de deformação plástica no processo. Dessa maneira, este trabalho tem por objetivo o desenvolvimento de um procedimento de avaliação de forças motrizes elasto-plásticas em tubos contendo juntas soldadas circunferenciais sujeitos a flexão, para uma extensa gama de configurações geométricas. Dois métodos distintos foram desenvolvidos e analisados: a metodologia EPRI e o procedimento que utiliza a curva de tensão vs. deformação equivalente. As análises numéricas 3D fornecem os parâmetros de fratura necessários para a resolução do problema e a acurácia dos procedimentos é verificada a partir de estudos de casos e análises paramétricas. / The increasing demand for energy has motivated the oil and natural gas exploration in very hostile environments, including very deep water operation and the transport of corrosive fluids. Technological advances favor the use of high strength steel pipelines either clad or mechanically lined with a corrosion resistant alloy (CRA), such as Alloy 625, for the transport of corrosive hydrocarbons. Moreover, these pipelines are subjected to severe installation conditions and a case of interest is the pipe reeling process, which allows pipe welding and inspection to be conducted at onshore facilities. While cost effective, fracture assessments and specification of critical flaw sizes for the girth welds of lined/clad pipes are more complex due to the dissimilar nature of these materials and the high levels of plastic strain imposed during installation. In particular, effective analyses of crack driving forces in undermatched or partially mismatched pipe girth welds remain essential to determine more accurate acceptable flaw sizes for the piping system based upon conventional ECA procedures. This work focuses on the development of a procedure to determine the elastic-plastic crack driving forces for pipe girth welds with circumferential surface cracks subjected to bending load for a wide range of geometries and weld mismatch levels based upon based methodologies: the GE-EPRI framework and the equivalente stress vs. strain curve. The study also addresses the potential effects of an undermatching girth weld on critical flaw sizes. The extensive nonlinear, 3-D numerical analysis provide the fracture parameters for cracked pipes and cylinders with mismatched girth welds which will be applied in case studies and parametric analyses in order to verify the accuracy of the methods.
262

Avaliação crítica de engenharia em dutos submersos sujeitos a flambagem lateral controlada. / Engineering critical assessment of submarine pipelines subjected to controlled lateral buckling.

Garmbis, Alexandre Galiani 17 October 2012 (has links)
Este trabalho busca avaliar o efeito da sobrepressão interna na avaliação crítica de engenharia (ECA) de dutos submersos sujeitos a flambagem lateral controlada, que essencialmente consiste na análise de carregamentos combinados associados a grandes deformações longitudinais. O objetivo principal é avaliar a viabilidade da adoção de corpos-de-prova SENT na avaliação da resistência à fratura em dutos sujeitos a esforços combinados utilizando procedimentos analíticos que incorporam do aumento das forças motrizes devido à sobrepressão interna. Este estudo apresenta uma revisão sobre os procedimentos de ECA utilizados em dutos submersos e sobre o efeito da pressão interna na capacidade de deformação de dutos. Os procedimentos adotados atualmente e procedimentos alternativos são discutidos e implementados em um problema prático envolvendo diferentes razões de diâmetros por espessuras, expoentes de encruamento, níveis de sobrepressão e deformação longitudinal. Alguns casos selecionados são comparados com soluções elasto-plásticas de J, e.g. EPRI. Os resultados apresentados fornecem uma boa compreensão sobre as vantagens e limitações de cada procedimento, incluindo a possibilidade de estender sua aplicação além do limite normativo de 0,4% de deformação longitudinal. / This work aims to evaluate the effect of internal overpressure on the engineering critical assessment (ECA) of submarine pipelines subjected to controlled lateral buckling, which essentially consists of the analysis of combined loading with large longitudinal strains at the buckle crown. The main goal is to evaluate the feasibility of using SENT specimens to characterize the fracture resistance in the assessments of pipelines subjected to combined loadings using analytical procedures that takes into account the increase of crack driving force due to internal overpressure. This study presents a revision about ECA procedures used in submarine pipelines and about the effect of biaxial stresses their tensile strain capacity. Both standard and alternative procedures are discussed and implemented in a practical problem involving different diameter to thickness ratios, hardening exponents, levels of internal pressure and longitudinal strain. Some selected cases are compared with full elastic-plastic J solutions, e.g. EPRI. The results provide useful insights regarding the advantage and limitations of each procedure, including the possibilities to extend their applicability beyond the standard limit of 0,4% of longitudinal strain.
263

Determinação de fatores plásticos ETA para avaliação de forças motrizes J e CTOD em corpos-de-prova SE(T) de juntas soldadas. / Determining factors plastics ETA for evaluating driving forces J and CTOD in body-of-proof SE (T) of welded joints.

Paredes Tobar, Lenin Marcelo 17 September 2012 (has links)
Este trabalho trata sobre o estudo numérico das forças motrizes (J e CTOD) em corpos-de-prova SE(T), usualmente extraídos da junta soldada do componente estrutural defeituoso, especificamente dutos submarinas (risers) com trincas circunferências alocadas no metal de solda. Durante o processo de instalação (reeling method) o duto é submetido a grandes carregamentos cíclicos (principalmente momentos de flexão) os quais introduzem fortes deformações plásticas (~2 e ~3%) afetando diretamente a integridade estrutural e a operação segura do sistema dutoviário. Procedimentos correntes aplicados na determinação da tenacidade à fratura de materiais, frequentemente, baseiam-se no coeficiente adimensional de proporcionalidade plástica (o fator n) e tem se mostrado válido em espécimes homogêneos. Para configurações com dissimilaridade mecânica, a aplicação direta deste método fica comprometida pelo grau de complexidade que existe entre a relação acoplada das forças motrizes (J e CTOD) e carregamento remoto com a dissimilaridade mecânica introduzida pelo processo de soldagem. O objetivo da presente tese é desenvolver um procedimento numérico de estimação de parâmetros de mecânica da fratura aplicáveis em configurações não padronizadas SE(T) para condições de dissimilaridade mecânica (weld strength mismatch). Uma extensiva análise de elementos finitos é desenvolvida na obtenção dos fatores n aplicáveis para espécimes SE(T) com várias profundidades de trincas (a/W) e níveis de dissimilaridade mecânica (My) para dois tipo de carregamento: garra (clamped end) e pino (pin loading). Três diferentes, mas correlatos métodos são aplicados para a obtenção acurada dos fatores n em condição de dissimilaridade mecânica, a saber, são: trabalho plástico, separação de cargas e carga limite. Os efeitos tridimensionais são analisados de forma sistemática para diferentes valores de espessura (B/W) e comprimentos do espécime (H/W) com a finalidade de avaliar a robustez das soluções obtidas das análises em estado plano de deformação. Finalmente, os resultados obtidos fornecem suporte para uso de espécimes SE(T) em procedimentos de avaliação de defeitos em dutos soldados submetidos a carregamento de flexão. / This work focuses on the numerical study of crack driving forces (J and CTOD) on single edge notch in tension (SE(T)) specimens usually extracted from defective structural components, specifically, circumferentially welded cracked pipes. The most efficient procedure to deploy submarine pipes (risers) on the sea floor is the reeling method. This procedure introduces a huge amount of cyclic loading to the girth welded pipe during the installation causing permanent plastic deformation (around ~2 to ~3%), which can affect the structural integrity and safe operation of the pipeline system. Current material fracture toughness procedures rely upon accuracy of proportionality plastic coefficient (also known n factor), which has to be effective for homogeneous condition. For mismatched configurations, where the strength of the weld metal is higher than the strength of base metal (also referred as overmatching), the direct applicability of such procedures remains a key aspect for defect assessment procedures and fitness for service codes, due to the complexity of the univocal relationship between crack driving forces and remote loading and the weld strength mismatch effect. The goal of the present thesis is to develop an estimation procedure of fracture mechanics parameters (J and CTOD) for SE(T) specimens in heterogeneous conditions. Extensive finite element analyses were conducted in order to obtain n factors for mismatched SE(T) specimens with varying crack lengths (a/W), different levels of overmatch (My) and two loading schemes (clamped and pin loading). Three different but related methods are applied to compute the n factor for welded mismatch configurations, namely the plastic work, load separation and limit load method. Also, the 3D effects are systematically analyzed for different thickness (B/W) and different specimen lengths (H/W) in order to prove the robustness of the proposed solutions derived from FE analyses in plane strain conditions. Finally, the results provide strong support for the use of constraint designed SE(T) specimens in fracture assessments of circumferential surface cracks in girth welded pipes subjected to bending moment.
264

Análise histológica e histométrica do processo de reparo em osteotomia realizada em corpo mandibular após uso de sistema de fixação interna de 2,0mm metálico e absorvível. Estudo experimental em cães / Comparative study of the bone repair in mandibular body osteotomy between metallic and absorbable 2.0 mm internal fixation systems. Histologic and histometric analysis in dogs.

Kato, Rogério Bentes 11 August 2010 (has links)
O objetivo deste estudo foi realizar uma análise histológica e histométrica do processo de reparo ósseo em osteotomias realizadas em mandíbulas de cães e estabilizadas com sistema de fixação interna (FI) de 2,0 mm absorvível e compará-las com o sistema metálico, considerado pela literatura como o gold-standard. Foram utilizados 12 cães, divididos em 2 grupos (Metálico e Absorvível), sendo que cada grupo possuía 2 períodos (2 e 18 semanas). A comparação das características do reparo ósseo entre os grupos foi analisada histologicamente em três 3 terços sendo, Terço de Tensão (TT), Terço Intermediário (TI) e Terço de Compressão (TC). Na análise histológica verificaram-se diferenças significantes entre terços, períodos e sistemas. O TC mostrou-se sempre em estagio mais avançado no processo de reparo em relação ao TT; o processo de reparo ósseo unindo os fragmentos foi observado no período de 18 semanas e não no de 2 semanas em ambos os sistemas; os padrões de reparo ósseo entre os sistemas mostraram-se diferentes. A análise histométrica não mostrou diferenças estatisticamente significante na distância entre os fragmentos ósseos no período de 2 semanas entre os terços e nem entre os sistemas. No período de 18 semanas a neoformação óssea observada foi estatisticamente maior no sistema metálico em relação ao sistema absorvível. Concluiu-se que, ambos os sistemas propiciaram a ocorrência do processo de reparo ósseo na área da osteotomia no período de 18 semanas; os padrões de processo de reparo ósseo mostraram-se diferentes entre os sistemas. / The purpose of this study was to perform a histological and histomorphometric analysis of bone repair process after dog mandible osteotomy stabilized with 2.0 mm absorbable internal fixation system (FS) comparing it to metallic fixation system considered the gold standard treatment. Twelve mongrel dogs were divided into 2 fixation material groups (metallic and absorbable groups) and into 2 period groups (2 and 18 weeks). Histological bone repair comparison was performed between the three thirds of the defects named Tension Portion (TP), Intermediate Portion (IP), and Compression Portion (CP). Histological analysis demonstrated significant difference between the thirds, the periods and fixation systems. CP demonstrated better results than TP; complete bone repair process was observed only at eighteen weeks period in both FS; however bone repair quality was different between FS. At two weeks the histomorphometric analysis showed no statistically significant differences in distance between the bone fragments, the thirds, and FS. After eighteen weeks the bone formation was statistically higher in metallic system fixation group than the absorbable group. The results suggested that both FS provided bone repair process on osteotomy site after eighteen weeks; bone repair process was different between the tested materials.
265

Processo de avaliação probabilística de integridade estrutural aplicado à otimização dimensional de elementos estruturais. / Process for probabilistic assessment of structural integrity applied to dimensional optimization of structural elements.

Namindome, Guilherme 08 August 2018 (has links)
Este trabalho de pesquisa visa apresentar um processo de avaliação probabilística de integridade mecânica de elementos estruturais, e ilustra sua aplicação em situações de otimização dimensional de tais elementos. O processo apresentado é baseado na análise de confiabilidade por métodos analíticos, utilizando o diagrama de avaliação de falha (FAD) como critério de falha. A escolha da curva FAD como critério de falha visa padronizar a análise de confiabilidade estrutural, permitindo a sua aplicação tanto em simulações numéricas quanto em mapas utilizados para rápidas tomadas de decisão. Os métodos de análise e o processo apresentado são aplicados em casos de estudo para mostrar a influência da percepção probabilística nas tomadas de decisão de projeto e a importância da análise de risco no dimensionamento de sistemas estruturais. / This work intends to present a process for probabilistic assessment of mechanical integrity of structural elements, and illustrates its application in situations of dimensional optimization of such elements. The presented process is based on the reliability analysis by analytical methods, using the failure assessment diagram (FAD) as failure criteria. The choice of FAD curve as a failure criteria aims to standardize the structural reliability analysis, allowing its application both in numerical simulations and in chart maps used for fast decision making. The methods of analysis and the presented process are applied in case studies to show the influence of probabilistic perception on project decision making and the importance of risk analysis in the design of structural systems.
266

[en] A ROBUST GENERALIZED FINITE ELEMENT METHOD APPLIED TO FRACTURE MECHANICS / [pt] UM MÉTODO ROBUSTO DE ELEMENTOS FINITOS GENERALIZADOS APLICADO À MECÂNICA DA FRATURA

WLASMIR CAVALCANTI DE SANTANA 26 March 2004 (has links)
[pt] Apesar da extensa aplicabilidade do Método de Elementos Finitos na representação e solução de problemas dos mais diversos campos da Engenharia, há ainda classes de problemas em que o seu uso encontra severas dificuldades. Uma delas está relacionada com a simulação da evolução temporal da geometria ou de condições de contorno móveis na Mecânica Computacional. Exemplos típicos destes problemas envolvem grandes deformações, propagação de trincas na mecânica da fratura, escoamentos bi-fásicos , transferência de calor em meios com mudança de fase , entre outros. Nestes casos, a tarefa do acompanhamento das modificações de geometria, dos deslocamentos nas interfaces e das descontinuidades a serem representadas pela malha de elementos finitos implica em modificações da discretização a cada passo da análise, o que requer o emprego de sofisticados procedimentos de adaptação ou de reconstrução da malha. Para atender a estas situações, duas classes de novas estratégias foram recentemente propostas na literatura: i) Métodos sem Malha, em que a discretização é estabelecida a partir de um conjunto de nós distribuídos sobre o domínio, dispensando o uso da entidade elemento e, ii) Método de Elementos Finitos Generalizados (MEFG), em que a capacidade de representação da base de funções de forma tradicionais do MEF é estendida utilizando-se funções específicas ao problema em analise. Neste trabalho investigam-se as características destas duas classes de métodos e, suas vantagens e limitações na aplicação à análise de problemas da mecânica da fratura computacional. Da comparação do desempenho destas técnicas na solução de problemas envolvendo descontinuidades localizadas demonstra-se que o MEFG é numericamente superior aos demais, em aplicações com a análise da propagação de trincas no contexto da Mecânica da Fratura Linear Elástica (MFLE). Por este método, o campo de deslocamentos representados no MEF tradicional por funções lagrangianas é adicionado (enriquecido) localmente por funções que representam as características de descontinuidade (trinca) presentes no contínuo de forma implícita e independente da malha. A nova base de funções incorpora também termos que representam a solução da mecânica da fratura linear elástica para os deslocamentos na vizinhança da ponta-de- trinca, mantendo as características de partição da unidade próprias do MEF. A formulação foi implementada em um programa para a análise de problemas planos juntamente com uma nova estratégia de integração numérica das equações de equilíbrio que permite eliminar o emprego de eventuais modificações da malha . Este procedimento de integração emprega uma composição das quadraturas de Gauss-Lobato e Gauss-Radau, capacitando o método à uma analise robusta sem o uso de quaisquer procedimentos de reconstrução de malha. Testes numéricos com modelos do MEFG são apresentados e discutidos , verificando-se uma boa correlação da solução numérica obtida com resultados experimentais ou outras soluções clássicas da MFLE. / [en] The Finite Element Method is certainly the most generally used technique for the solution of Engineering problems. However, there are some classes of problems in which the method is still not straightly applicable. One of those is related to the simulation of problems with moveable geometry and/or boundary conditions, in the field of Computation Mechanics. Typical examples are found in fields such : large deformations, crack propagation, two- phase flow, heat transfer with phase change, and so on. In these cases, because displacements at the interfaces and the geometry are to be followed throughout the solution, a regular finite element procedure becomes too cumbersome to represent, requiring the use of sophisticated procedures for adaptation and mesh reconstruction. To overcome these difficulties, two classes of new numerical procedures have been recently proposed: i) Meshless Methods (MM), where the state-variables are interpolated by a set of node values, within the problem domain, without using element boundaries and, ii) Generalized Finite Elements Method (GFEM), where the interpolation function basis is expanded in order to accommodate specific interpolation functions, adjusted to the problem in consideration. In this work the characteristics of these two procedures were evaluated considering their applications to numerical problem solutions, in the field of fracture mechanics. It is demonstrated that the GFEM results in a better numerical procedure considering applications to the crack propagation problem, in the context of linear fracture mechanics. In this method, the displacement fields provided by standard FEM are locally enriched by specific functions which represent, implicitly and independently of the mesh, the requirements for displacement discontinuities. The new function basis also incorporates a solution for the displacements in the neighborhood of the crack tip, obtained from linear fracture mechanics solution. The formulation has been implemented for the analysis of plane problems using a new numerical integration strategy, for numerical evaluation of the equilibrium equations. This integration procedure uses a composition of Gauss-Lobato e Gauss-Radau quadratures, assuring the method numerical robustness, with no requirements for mesh reconstruction. Numerical test solutions with GFEM models are compared to experimental and other classic solutions to demonstrate the method applicability to the analysis of linear fracture mechanics problems.
267

Avaliação da força de compressão dos parafusos sem cabeça (HCS) - modelo experimental de fraturas do escafoide em ossos sintéticos / Evaluation of the compressive force of the headless compression screw (HCS) - experimental model of scaphoid fractures in synthetic bone

Shimaoka, Filipe Jun 09 February 2017 (has links)
A força de compressão entre os fragmentos é um importante fator que interfere na consolidação das fraturas. O objetivo deste trabalho foi avaliar a eficácia de cada um dos parafusos sem cabeça de auto compressão com três diâmetros de rosca diferentes, empregados no tratamento das fraturas do escafoide. Utilizando um dispositivo de alumínio acoplado à uma máquina universal de ensaios equipada com uma célula de carga de 50 kgf. Foram utilizados dois blocos de espuma rígida de poliuretana de densidade 0,16 g/cc. Os testes foram realizados com os parafusos HCS da marca Synthes®, com diâmetros de 3,0 mm, 2,4 mm e 1,5 mm. Todos tinham 20 mm de comprimento. Os parafusos foram introduzidos utilizando os princípios da técnica AO, sendo o instrumental fornecido com os parafusos. Foram realizados com os parafusos supracitados fixações com inserção a 90º, 60º, 45º e 30º de inclinação em relação à superfície do bloco. Todos procedimentos foram repetidos por sete vezes, comparando-se os valores obtidos do pico da força de compressão (Força Max), da força de compressão após 20 segundos (Força T1) e da força de compressão após 300 segundos (Força T2). Para as fixações dos parafusos de 3.0 mm e 2.4 mm com 30º de inclinação não houve compressão, devido ao rompimento da superfície do bloco pela rosca da extremidade proximal dos parafusos. A Força Max do parafuso HCS de 3.0 mm foi maior do que a dos parafusos de 2.4 mm em todas as comparações. A relação entre as Força T2/Força T1 foram semelhante em todas as comparações, isto é, não apresentaram diferença estatística, e demostraram que a acomodação dos parafusos não foi relacionada ao diâmetro da rosca dos parafusos. Concluímos que a força de compressão entre os fragmentos foi maior quando o diâmetro da rosca do parafuso também foi maior, independente da posição da inserção em relação à fratura / The interfragmentary compression force is an important factor for fracture healing. The aim of this study was to evaluate the effectiveness of each three different diameters headless compression screw, used for the treatment of scaphoid fractures. It was used an aluminum device coupled to a universal testing machine equipped with a load cell of 50 kgf. Two rigid foam blocks made of polyurethane with density of 0.16 g/cc. The tests were performed with the HCS Synthes® with 20 mm length 3.0 mm, 2.4 mm and 1.5 mm in diameter. The screws were inserted using the AO technique and instrumental provided with screws. They were performed with the above screw with 90º, 60º, 45º and 30º tilt with the block and repeated seven times and comparing the results obtained from the peak compression force (Max Force) to compression force after 20 seconds (T1 Force) and compression force after 300 seconds (T2 force). For the fixations of 3.0 mm and 2.4 mm screws with 30° tilt no compression were reached, as the proximal threads of the screws broke the surface of the block. Max Force for HCS 3.0 mm was higher than the 2.4 mm screws in all comparisons. The relationship T2 Force / T1 Force was similar in all comparisons, showing no statistical difference, proving that the accommodation of the screws is not related to the threads diameter of the screws. It was concluded in this work that there was a reduction of interfragmentary compressive force by reducing the threads diameter of the screws, regardless of the position placed over the fracture surface
268

Estado nutricional relativo ao zinco de idosos com fratura do quadril, submetidos à suplementação com cálcio e vitamina D / Nutritional status for zinc in the elderly with hip fracture, submitted to supplementation with calcium and vitamin D

Guilherme, Fernanda Carla Coelho 21 September 2009 (has links)
A literatura tem demonstrado a importância dos minerais traço na manutenção da qualidade óssea, através de seu papel no metabolismo de metaloenzimas, na síntese de colágeno e de outras proteínas que formam a estrutura dos ossos. Dentre estes minerais, destaca-se o zinco. Sabendo que indivíduos idosos apresentam um estado nutricional deficiente em relação a este mineral; que a expectativa de vida geral da população está aumentando, contribuindo para uma elevada incidência de fraturas, principalmente devido à osteoporose; e que cada vez mais é recomendado suplementação com cálcio e vitamina D para esses pacientes, foi realizado um estudo longitudinal, aleatório, que teve como objetivo avaliar se essa suplementação altera o estado nutricional dos idosos em relação ao zinco. Para tanto, foram selecionados 28 idosos, com fratura do quadril, com idade de 60 anos ou mais, distribuídos em dois grupos: um recebendo suplementação com cálcio e vitamina D, e outro sem suplementação. Não houveram diferenças estatisticamente significativas em relação ao gênero, à média da idade e do IMC entre os dois grupos. A avaliação do consumo alimentar foi realizada por meio do software Nutwin. O zinco foi analisado pelo método de espectrofotometria de absorção atômica por chama. A determinação da 25(OH)D foi realizada por Cromatografia Líquida de Alta Eficiência (CLAE). A maioria dos participantes apresentou IMC de acordo com os valores de referência considerados normais para idosos e adequação energética inferior ao recomendado. A porcentagem dos macronutrientes da dieta analisada estava dentro dos limites de normalidade. O consumo de zinco e cálcio alimentares foi inferior ao recomendado segundo as DRIs para a maioria dos idosos dos dois grupos avaliados. A média das concentrações de zinco plasmático foi menor que o valor de referência nos dois grupos, sem diferença estatística significativa entre estes (p>0,05). Em relação ao zinco eritrocitário, embora o grupo suplementado tenha apresentado a média das concentrações dentro da normalidade, o grupo não suplementado apresentou concentrações superiores ao valor de referência, sendo esta diferença estatisticamente significativa (p<0,05). Foi observado que todos os idosos com fratura do quadril encontravam-se em hipovitaminose D. Portanto, os resultados nos permitem concluir que a suplementação não teve influência no estado nutricional relativo ao zinco nos pacientes estudados. / The literature has demonstrated the importance of trace minerals in maintaining bone quality through its role in the metabolism of metaloenzyme, the synthesis of collagen and other proteins that form the structure of bones. Among these minerals is zinc. Knowing that the elderly have a poor nutritional status in relation to this mineral, that the life expectancy of the general population is increasing, contributing to a high incidence of fractures mainly due to osteoporosis, and that is increasingly recommended supplementation with calcium and vitamin D for these patients, a study was conducted longitudinal, randomized, which aimed to assess whether this supplementation alters the nutritional status of elderly in relation to zinc. Thus, we selected 28 elderly patients with hip fracture aged 60 years or more, divided into two groups: one receiving calcium and vitamin D supplementation and the other one without supplementation. There were no statistically meaningful differences in relation to gender, the average age and BMI between the two groups. The assessment of food consumption was done using the software Nutwin. Zinc was analyzed by the method of flame atomic absorption spectrophotometry. The determination of 25(OH)D was performed by High Performance Liquid Chromatography (HPLC). Most participants showed BMI according to the reference values considered normal for the aged and lower energy adequacy than recommended. The percentage of macronutrients of the analyzed diet was considered within the normal range. The consumption of dietary zinc and calcium was lower than recommended by the DRIs for most elderly of the two groups evaluated. The average concentrations of plasma zinc was lower than the reference value in both groups without important statistical difference between them (p>0,05). Regarding erythrocyte zinc, whereas the supplemented group has presented the average concentrations within the normal range, the non-supplemented group showed concentrations above the reference value, the difference being statistically significant (p<0,05). It was observed that all elderly patients with hip fracture were in hypovitaminosis D. Therefore, the results allow us to conclude that supplementation had no influence on nutritional status for zinc in tested patients.
269

Avaliação eletromiográfica do músculo masseter nos pacientes portadores de fratura de face / The electromyographic study of masseter muscle in patients with facial fracture

Campolongo, Gabriel Denser 16 April 2012 (has links)
Este estudo analisou por meio de um eletromiógrafo de superfície as atividades dos músculos masseteres, direito e esquerdo, de 30 pacientes com diagnóstico de fratura de ossos da face, com uma média de 1,33 fraturas por paciente, em quatro momentos, no pré-operatório e nos pós-operatórios equivalentes ao 7°, 30° e 60° dias posteriores à cirurgia. Considerou-se o valor de cada medida, a média entre três contrações máximas isométricas voluntárias de duração de cinco segundos cada uma. Os paciente foram agrupados de acordo com o diagnóstico da fratura, sendo com fratura da mandíbula 50%, fratura do zigomático 33%, fratura da maxila 10% e com fraturas associadas 6,7%. Os pacientes apresentaram menor atividade dos músculo masseter no período pré-operatório, quando comparado a valores considerados normais, em todos os grupos de fraturas, seguida de queda acentuada no pós operatório de 07 dias, sendo que todos os grupos apresentaram recuperação da atividade em 60 dias, porém abaixo do valor normal encontrado na literatura. Os valores médio observados foram em ordem decrescente: fratura de zigomático, fratura de mandíbula, fratura de maxila e fraturas associadas. As fraturas de mandíbulas unilaterais apresentaram maiores valores que as fraturas bilaterais na maioria dos tempos. Houve diferença altamente significante na comparação da evolução da atividade do músculo masseter direito e esquerdo para as fraturas de mandíbula e de zigomático, sendo que na comparação par a par houve diferença significante entre a maioria dos grupos. / This study analyzed using a surface electromyographic activity of the masseter muscles, right and left, of 30 patients with fractures of facial bones, with an average of 1.33 fractures per patient, four times, the pre-operative and postoperative equivalent to the 7th, 30th and 60th days after surgery. It was considered the value of each measurement, the average of three isometric maximum voluntary contractions for five seconds each. Patients were grouped according to the diagnosis of fracture, 50% of the mandible fracture, 33% of the zygomatic fracture, 10% of maxilla fracture and 6,7% with associated fractures. The patients showed lower activity of the masseter muscle in the preoperative period, when compared to normal values in all groups of fractures, followed by a sharp drop in the postoperative period of 07 days, and all groups showed a recovery of activity in 60 days, but below the normal value found in the literature. The average values were observed in decreasing order: zygomatic fracture, mandible fracture, maxilla fracture and associated fractures. The unilateral jaw fractures showed higher values than the bilateral fractures in most of the times. There was a highly significant difference in comparing the evolution of the activity of the masseter muscle right and left to the mandibular and zygomatic fractures, if compared pairwise significant difference between most groups.
270

Propriedades mecânicas de dois sistemas de osteossíntese empregando placa volar de rádio distal / The biomechanical properties in two osteosynthesis systems using volar distal radius plate

Pinto Netto, Henrique de Barros 29 June 2017 (has links)
Avaliar as propriedades mecânicas em dois sistemas de osteossíntese com o emprego de placa volar de rádio distal, alterando-se o tipo de parafuso utilizado quais sejam: bloqueados ou corticais, na fileira distal da placa bem como a colocação ou não de enxerto ósseo em modelos ósseos Sawbone(TM). Trata-se de um estudo experimental de fraturas do rádio distal extra articular, consideradas instáveis, com dois fragmentos e com uma cunha dorsal de 11 mm (classificação AO 23 A3) e também com modelo de osteotomia de cunha aberta, frequentemente empregado por cirurgiões ortopédicos, na prática clínica. Foram usados 10 (dez) ossos rádios Sawbone(TM) esquerdos (Código: 3407), validados para estudo biomecânico, os quais foram divididos em dois grupos de cinco ossos cada. Os grupos foram submetidos a dois sistemas de osteossíntese: sistema de fixação 1, placa volar de ângulo variável esquerda VA-LCP, dupla coluna, seis/três furos, com quatro parafusos bloqueados distais, dois parafusos bloqueados proximais e mais um parafuso cortical proximal e o sistema de fixação 2, utilizou a mesma placa volar de rádio, porém apenas trocou na fileira distal os quatros parafusos corticais. Os modelos foram submetidos a testes mecânicos de flexão dorsal de 30 N e compressão axial de 250 N para avaliar a deflexão e a rigidez dos sistemas, alternando a colocação do enxerto ósseo. A seguir, houve o ensaio de carregamento cíclico de compressão de 250 N por 1000 HZ, simulando-se um pós-operatório de 6 semanas. Na segunda parte do estudo, foram realizados os mesmos testes de compressão axial e flexão dorsal, usando as mesmas forças de carregamento empregadas na primeira fase dos ensaios mecânicos, para avaliar as possíveis alterações na deflexão e rigidez. Para se comparar as medidas aferidas entre os testes de flexão dorsal e compressão axial antes e depois do carregamento cíclico foi empregado o teste de U de Mann-Whitney, considerando-se um nível de significância de 5%. Ao analisar os resultados obtidos, o sistema de fixação com parafuso cortical com enxerto (CC) se mostrou mais rigído, tanto na deflexão quanto na compressão ao ser comparado com os demais sistemas de fixação, principalmente com o bloqueado sem enxerto (BS). Quanto a relevância clínica do estudo placas volar de rádio distal são comumente usadas nos tratamentos das fraturas do rádio distal, porém a configuração ideal dos parafusos distais não foi determinada. O sistema de fixação com quatro parafusos corticais com enxerto ósseo do ponto de vista biomecânico in vitro, os resultados se mostraram bastante confiáveis como uma proposta de tratamento. / Evaluating the biomechanical properties in two osteosynthesis systems using a volar distal radius plate by changing the type of screw used, whether locked or cortical, in the distal row of the plate, with or without bone grafting in Sawbone (TM) models. This is an experimental study of fractures of the extra articular distal radius, considered to be unstable, with two fragments and a dorsal wedge of 11 mm (AO 23 A3 classification), as well as the open-wedge osteotomy model frequently used by Orthopedic surgeons, in clinical practice. Ten left-hand radios bones, Sawbone (TM) (Code: 3407), validated for biomechanical studies were used. These were then divided into two groups of 5 bones each. The groups were submitted to two osteosynthesis systems: fixation system 1, VA-LCP left variable-angle volar plate, double-column, 6/3 holes, with four distal locked screws, two proximal locked screws and one proximal cortical screw. The fixation system 2 used the same volar plate, but only the four cortical screws were changed in the distal row. The models were submitted to mechanical tests of dorsal flexion of 30 N and axial compression of 250 N to evaluate the deflection and stiffness of the systems, changing the placement of the bone graft. Next, there was the cyclic loading test of 250 N per 1000 HZ, simulating a 6-week post-op. In the second part of the study, the same tests of axial compression and dorsal flexion were performed, using the same loading forces used in the first phase of the mechanical tests to evaluate the possible changes in deflection and stiffness. In order to compare the results between the dorsal flexion tests and axial compression before and after the cyclic loading, the Mann-Whitney U test was used, considering a level of significance of 5%. When analyzing the results obtained, the cortical screw fixation system with graft was shown to be more rigid, both in deflection and in compression when compared to the other fixation systems, especially with the locked system without graft. Regarding the clinical relevance of the study, the volar distal radius plate is commonly used in the treatments of distal radius fractures, however the ideal configuration of the distal screws has not yet been determined. The results of the fixation system with four cortical screws with bone graft, from a biomechanical point of view in vitro, proved to be a reliable form of treatment.

Page generated in 0.0287 seconds