• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • 61
  • 48
  • 22
  • 18
  • 9
  • 8
  • 6
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 336
  • 183
  • 62
  • 60
  • 48
  • 46
  • 42
  • 38
  • 34
  • 33
  • 33
  • 32
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Évaluation de l'excrétion urinaire d'un biomarqueur pour la maladie de Fabry, le globotriaosylcéramide (Gb[indice inférieur 3]), chez des enfants normaux de la naissance à 6 mois

Barr, Caroline January 2009 (has links)
La maladie de Fabry est une maladie héréditaire de surcharge, dont la transmission est liée au chromosome X qui résulte d'un déficit de l'[alpha]-galactosidase A. Le déficit enzymatique mène à une augmentation de glycosphingolipides, notamment le globotriaosylcéramide (Gb[indice inférieur 3]), dans les tissus et fluides biologiques. Le Gb[indice inférieur 3] est donc un biomarqueur ou indicateur de la présence de cette maladie chez les patients Fabry. Nous voulions évaluer la faisabilité de procéder à un projet pilote de recherche en vue d'un dépistage néonatal urinaire de la maladie de Fabry.La variation de l'excrétion du Gb[indice inférieur 3]/créatinine urinaire chez des enfants normaux dans la période néonatale jusqu'à l'âge de 6 mois est inconnue. Cette constatation nous a conduits au questionnement suivant : existe-t-il une variation dans la quantité du Gb[indice inférieur 3]/créatinine urinaire excrétée chez des enfants normaux de 0 à 6 mois de vie? Afin de répondre à cette question, nous avons procédé à une étude permettant de doser le Gb[indice inférieur 3]/créatinine chez des enfants normaux par spectrométrie de masse en tandem et ce, en comptant sur la collaboration des parents à effectuer un total de treize prélèvements d'urine pendant une période de 6 mois. Nous avons d'ailleurs évalué ladite collaboration des parents à nous faire parvenir les échantillons d'urine de leur bébé durant cette période. Nous avons utilisé une méthode par spectrométrie de masse en tandem avec des échantillons d'urine séchée sur papier filtre pour analyser simultanément le Gb[indice inférieur 3] total urinaire et la créatinine à différents temps soit 2, 3, 4, 6, 10, 14, 21, 28 jours, de même qu'à 2, 3, 4, 5 et 6 mois chez 37 filles et 39 garçons normaux. Le traitement quantitatif des données de la créatinine et du Gb[indice inférieur 3] urinaire a été fait par le logiciel QuanLynx (Waters). Nous avons divisé la variable du temps en quatre périodes pour les fins d'analyses statistiques : (1) < 6 jours; (2) 6-29 jours; (3) 30-90 jours; (4) > 90 jours. Nous avons procédé à des analyses statistiques comparatives du rapport Gb[indice inférieur 3]/créatinine de 728 échantillons pour les deux cohortes en fonction du temps. Une analyse de variance a été faite pour évaluer l'effet de l'âge et du sexe sur le rapport du logarithme du Gb[indice inférieur 3]/créatinine urinaire et l'effet de l'âge et du sexe sur la quantité d'excrétion de la créatinine urinaire seulement. Nous avons observé un effet significatif de l'âge sur la créatinine (p < 0.0001). En ce qui concerne les résultats du rapport du Gb[indice inférieur 3]/créatinine, il y a une augmentation non significative de la médiane dans les périodes 1 et 2 pour les garçons (Période 1: Médiane 53.9; Min-Max 0 - 369.3 [micro]g/mmol créatinine; Période 2: Médiane 92.5; Min-Max 0 - 611.1 [micro]g/mmol créatinine ; p = 1.0000). Chez les filles, l'excrétion du Gb[indice inférieur 3]/créatinine est plus élevé à la naissance et présente une tendance à l'accroissement entre les périodes 1 et 2 (Période 1: Médiane 59.5; Min-Max 0 - 669.9 [micro]g/mmol créatinine; Période 2: Médiane 96.1; Min-Max 0 - 456.1 [micro]g/mmol créatinine ; p = 1.0000). Par ailleurs, l'excrétion du Gb[indice inférieur 3]/créatinine chez les garçons diminue de façon significative entre les périodes 2 et 4 (Période 2: Médiane 92.5; Min-Max 0 - 611.1 [micro]g/mmol créatinine; Période 4: Médiane 14.6; Min-Max 0 - 158.5 [micro]g/mmol créatinine ; p < 0.0001); au niveau des filles, il y a une diminution non significative de la médiane de la période 2 à la période 3 (Période 2 : Médiane 96.1; Min-Max 0 - 456.1 [micro]g/mmol créatinine ; Période 3 : Médiane 35.6; Min-Max 0 - 254.4 [micro]g/mmol créatinine p = 0.2290) et une légère augmentation à la période 4 (Période 4 : Médiane 42.7; Min-Max 0 - 617.2 [micro]g/mmol créatinine). Ainsi, nous pouvons constater qu'il existe une grande variabilité de l'excrétion du Gb[indice inférieur 3]
262

L'interféromètre Virgo :<br />propriétés optiques, stabilisation en fréquence du laser

Bondu, François 06 June 2008 (has links) (PDF)
Un interféromètre à miroirs suspendus convertit les ondes gravitationnelles, perturbations de la géométrie de l'espace temps, en une variation de temps de vol d'aller-retour de photons entre deux masses inertielles au repos.<br />J'ai réalisé l'asservissement en fréquence du laser pour mesurer ces variations de temps de vol. La stabilité relative de fréquence en boucle du laser est de 1e-21 sur 100 ms ; je montre que le système obtenu respecte les spécifications. J'étudie dans le mémoire les propriétés d'un système où les boucles d'asservissements sont imbriquées.<br />Les cavités optiques résonnantes de l'interféromètre Virgo sont les éléments essentiels de la conversion d'une onde gravitationnelle. J'étudie l'ensemble des propriétés d'un oscillateur Fabry-Perot. Je montre comment elles peuvent être évaluées in situ à partir de mesures des fonctions de transfert utilisées pour leur verrouillage. Les cavités Fabry-Perot sont les oscillateurs de référence. Je fais un état des lieux de l'ensemble des perturbations susceptibles de perturber la stabilité de phase.
263

Ingénierie de mode en optique intégrée sur silicium sur isolant

Velha, Philippe 13 February 2008 (has links) (PDF)
Cette thèse porte sur la localisation et la manipulation de la lumière à l'échelle de la longueur d'onde. Les travaux ont d'abord porté sur des micro-cavités à grands facteurs de qualité (Q) intégrées sur des guides rubans reposant sur un substrat (SOI). L'optimisation des miroirs grâce à une ingénierie de mode basée sur l'adaptation des profils des modes, a permis d'obtenir des Q allant jusqu'à 60000 pour un volume modal de 0,6(lambda/n)3. Le confinement a pu être observé par microscopie en champ proche et nous avons montré qu'il était possible de contrôler ces cavités par une pointe SNOM. . Enfin, nous nous sommes intéressés aux modes lents en abordant de façon théorique l'injection efficace de la lumière dans un mode lent.
264

Optimisation des observations et des données cinématiques H[alpha] de l'échantillon de galaxies proches SINGS

Daigle, Olivier January 2005 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
265

Force Sensing and Teleoperation of Continuum Robot for MRI-Guided Surgery

Su, Hao 24 April 2013 (has links)
Percutaneous needle placement, a minimally invasive procedure performed dozens of millions in the U.S. each year, relies on dedicated skill and long-term training due to difficult control of needle trajectory inside tissue and mental registration of images to locations inside the patient. Inaccurate needle placement may miss cancer tumors during diagnosis or eradicate healthy tissue during therapy. MRI provides ideal procedure guidance with the merit of excellent soft tissue contrast and volumetric imaging for high spatial resolution visualization of targets and surgical tool. However, manual insertion in the bore of an MRI scanner has awkward ergonomics due to difficult access to the patient, making both training and intervention even harder. To overcome the challenges related to MRI electromagnetic compatibility and mechanical constraints of the confined close-bore, a modular networked robotic system utilizing piezoelectric actuation for fully actuated prostate biopsy and brachytherapy is developed and evaluated with accuracy study. To enhance manipulation dexterity, two kinds of steerable continuum needle robots are developed. The asymmetric tip needle robot performs needle rotation and translation control to minimize tissue deformation, and increase steering dexterity to compensate placement error under continuous MRI guidance. The MRI-guided concentric tube robot is deployed to access delicate surgical sites that are traditionally inaccessible by straight and rigid surgical tools without relying on tissue reaction force. The master-slave teleoperation system with hybrid actuation is the first of its kind for prostate intervention with force feedback. The teleoperation controller provides the feel and functionality of manual needle insertion. Fabry- Perot interferometer based fiber optic force sensor is developed for the slave manipulator to measure needle insertion force and render proprioception feedback during teleoperation.
266

Multiplexed optical fibre sensors for civil engineering applications

Childs, Paul, Electrical Engineering & Telecommunications, Faculty of Engineering, UNSW January 2007 (has links)
Fibre-optic sensors have been the focus of a lot of research, but their associated high cost has stifled their transferral from the laboratory to real world applications. This thesis addresses the issue of multiplexing, a technology that would lower the cost per unit sensor of a sensor system dramatically. An overview of the current state of research of, and the principles behind, multiplexed sensor networks is given. A new scheme of multiplexing, designated W*DM, is developed and implemented for a fibre Bragg grating (FBG) optical fibre sensor network. Using harmonic analysis, multiplexing is performed in the domain dual to that of the wavelength domain of a sensor. This scheme for multiplexing is compatible with the most commonly used existing schemes of WDM and TDM and thus offers an expansion over, and a resultant cost decrease from, the sensor systems currently in use. This research covered a theoretical development of the scheme, a proof of principle, simulated and experimental analysis of the performance of the multiplexed system, investigation into sensor design requirements and related issues, fabrication of the sensors according to the requirements of the scheme and the successful multiplexing of eight devices (thus offering an eightfold increase over current network capacities) using this scheme. Extensions of this scheme to other fibre sensors such as Long Period Gratings (LPGs) and blazed gratings were also investigated. Two LPGs having a moir?? structure were successfully multiplexed and it was shown that a blazed Fabry Perot grating could be used as a tuneable dual strain/refractive index sensor. In performing these tests, it was discovered that moir?? LPGs exhibited a unique thermal switching behaviour, hereto unseen. Finally the application of fibre sensors to the civil engineering field was investigated. The skill of embedding optical fibre in concrete was painstakingly developed and the thermal properties of concrete were investigated using these sensors. Field tests for the structural health monitoring of a road bridge made from a novel concrete material were performed. The phenomenon of shrinkage, creep and cracking in concrete was investigated showing the potential for optical fibre sensors to be used as a viable research tool for the civil engineer.
267

Mesure vectorielle de champs électriques microondes et de température par transducteurs électro-optiques

Bernier, Maxime 25 November 2008 (has links) (PDF)
Les cristaux électro-optiques (EO) comme le LiTaO3, présentent un indice de réfraction qui dépend linéairement, via l'effet Pockels, de l'amplitude d'une composante unique du champ électrique qui lui est appliqué, propriété qui permet de les utiliser comme détecteurs entièrement diélectriques, dédiés à la mesure vectorielle et non perturbative de champs électriques. Comme cette propriété est due à des effets non-linéaires, ces sondes EO possèdent des sensibilités (champ minimum mesurable) intrinsèquement faibles. Des sondes EO basées sur la modulation d'amplitude, utilisant une cavité Fabry-Pérot, permettent néanmoins d'améliorer cette sensibilité de plusieurs ordres de grandeur. Malheureusement les propriétés optiques de ces cristaux dépendent également de la température, engendrant une instabilité temporelle de la réponse EO de la sonde pour des mesures dites de «terrain».<br /> Le système développé au sein de l'IMEP-LAHC, en collaboration avec le centre d'étude de Gramat, et presenté dans ce manuscrit, a permis d'aboutir à la première mesure simultanée d'une composante du champ électrique et de la température avec une précision de l'ordre de 40 mK, et ce pendant plusieurs minutes dans des conditions expérimentales drastiques. Ce transducteur EO présente une réponse plate sur une bande spectrale allant du quasi DC à 16 GHz, une résolution spatiale d'une centaine de micron et une sélectivité supérieure à 25 dB.
268

Mise en oeuvre de concepts de détecteurs optiques de fluorescence intégrant la source de lumière au composant pour des immunoanalyses adaptées à des aplications hors laboratoire.

Galland, Rémi 22 September 2008 (has links) (PDF)
Afin de répondre aux contraintes des nouveaux champs d'applications des biocapteurs, le laboratoire LISA a développé un lecteur optique de fluorescence pour des immunoanalyses permettant une détection en continue. Cet instrument, dont le support de la réaction biologique est une lame de verre, utilise le couplage de la fluorescence en champ proche dans celle-ci. Mon travail de thèse a consisté à rechercher les possibilités d'améliorer les performances de compacité, de robustesse et d'adaptabilité du système en cherchant à intégrer les sources d'excitation de type OLED dans la lame de verre. La recherche d'une configuration adaptée à nos contraintes de détection nous a d'autre part poussé à étudier la répartition de l'émission de molécules fluorescentes à l'interface d'un substrat stratifié.<br />Pour ce faire, un modèle théorique basé sur la décomposition en ondes planes de l'émission d'un dipôle a été développé. Ce modèle nous a permis d'étudier à la fois les propriétés d'émission de sources organiques de types OLED ainsi que celles de molécules fluorescentes situées à l'interface d'un milieu massif recouvert ou non par une couche mince. <br />Une étude expérimentale et théorique de sources organique situées à l'intérieur d'une cavité Fabry Pérot a permis de fournir des réponses concrètes aux deux principaux défauts inhérents aux OLED pour leur intégration, la directivité angulaire d'émission et la largeur spectrale. Enfin, l'étude de lame de verre recouverte par une couche mince de Nitrure de Silicium a montré qu'il était possible d'améliorer le rapport signal sur bruit du détecteur et a permis de valider la configuration de l'instrument mis au point au laboratoire.
269

Mesure précise de la polarisation du faisceau d'électrons à TJNAF par polarimétrie Compton pour les expériences G^p _E et N-\Delta

Escoffier, Stéphanie 19 October 2001 (has links) (PDF)
Ce travail présente les mesures de la polarisation par effet Compton du faisceau d'électrons de l'accélérateur TJNAF pour les expériences de mesure des facteurs de forme électromagnétiques du proton et de mesure des fonctions de réponse du nucléon dans la réaction de l'électroproduction de pion au voisinage de la résonance 6.(1232). Le polarimètre Compton, dont le principe repose sur la diffusion élastique électron-photon, a été conçu et réalisé autour d'une cavité Fabry-Perot de finesse élevée, de l'ordre de 25000. La puissance du laser incident, de type Nd:YAG à la longueur d'onde 1064 nm, est accumulée dans la cavité optique afin d'obtenir une luminosité d'interaction telle que la précision statistique sur la mesure de la polarisation des électrons atteigne 1% en une heure. La fréquence du laser est asservie par la méthode Pound-Drever à une fréquence de résonance de l'interféromètre. La polarisation circulaire du faisceau de photons dans la cavité a été mesurée égale à 99.6+/-0.45%. Cette grandeur, ainsi que la mesure de l'asymétrie expérimentale et du pouvoir d'analyse de notre instrument, intervient directement dans la mesure de la polarisation du faisceau d'électrons. Le pouvoir d'analyse a été déterminé par une caractérisation de la réponse du détecteur de photons, un calorimètre composé de 25 cristaux de PbW04, à l'aide des événements détectés en coïncidence avec le détecteur d'électrons, composé de 4 plans de 48 'pistes de silicium. Les incertitudes de mesure proviennent principalement de la modélisation de la fonction de réponse du détecteur, de l'effet d'empilement de la mesure de la polarisation des photons. L'incertitude relative totale sur la mesure de Pe est de 1.4% pour une prise de données de 40 minutes. Le polarimètre Compton permet aussi de mesurer les différences d'hélicité entre deux renversements de la polarisation des électrons. Celle ci a été trouvée compatible avec zéro à 0.3% près.
270

Génération et amplification de plasmon polaritons de surface aux longueurs d'onde télécom au moyen de dispositifs compacts à semi-conducteur

Costantini, Daniele 07 March 2013 (has links) (PDF)
La plasmonique est un domaine de la nano-photonique qui étudie le comportement de la lumière à des échelles sub-longueurs d'ondes en présence de métaux. Les plasmons polaritons de surface (SPPs) sont des modes électromagnétiques qui se propagent à l'interface entre un diélectrique et un métal. Les SPPs trouvent des applications dans plusieurs domaines comme la communication et le traitement tout-optique du signal, la spectroscopie, la détection en biologie et en chimie. De nombreux composants plasmoniques (modulateurs, coupleurs, détecteurs ...) ont été démontrés ces dernières années. Cependant, leur l'intégration reste conditionnée par l'absence d'un générateur compact (pompage électrique, dimensions réduites) et par les grandes pertes ohmiques. Les techniques standards de génération de SPs nécessitent l'alignement d'un laser externe sur un prisme ou un réseau de diffraction afin d'adapter le vecteur d'onde incident avec celui du plasmon. L'approche que nous avons choisie est basée sur l'utilisation de lasers à semiconducteur ayant une polarisation transverse magnétique (TM) comme source d'excitation et de gain. Notre approche, permet d'obtenir des dispositifs compacts et facilement intégrables sur puce. Pendant ma thèse j'ai étudié expérimentalement et numériquement les performances d'un laser en fonction rapprochement du contact métallique à sa région active. La proximité du gain optique au métal est nécessaire pour la réalisation de dispositifs plasmoniques actifs. J'ai démontré la génération et l'amplification des plasmons de surface dans la bande télécom (λ=1.3µm), avec des dispositifs compacts, à base de semiconducteurs, fonctionnant par injection électrique et à température ambiante. Notamment, j'ai réalisé une architecture élégante, avec coupleur intégré, pour la génération de SPPs accessibles sur le sommet du dispositif. Un dispositif avec gaine superficielle ultrafine a permis de démontrer un mode hybride plasmonique avec une fraction consistante de champ électrique à l'interface métal/semiconducteur. Finalement, j'ai montrée que la structuration nanométrique du contact métallique réduit les pertes du mode laser. Les résultats sont renforcés par une nouvelle technique de imagerie de champ proche (SNOM) qui a permis de mesurer les SPPs à l'interface métal/or et à l'interface métal/ semiconducteur. Grâce aux mesures SNOM, il a aussi été possible de démontrer sans aucune ambiguïté l'effet de la structuration du métal sur le mode optique.

Page generated in 0.0181 seconds