• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 7
  • 3
  • 1
  • Tagged with
  • 127
  • 91
  • 51
  • 43
  • 41
  • 40
  • 40
  • 38
  • 36
  • 35
  • 32
  • 27
  • 27
  • 25
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Localiza??o de faltas em linhas de transmiss?o de m?ltiplos terminais a partir de registros oscilogr?ficos sincronizados via transformada wavelet

Cruz, Melinda Cesianara Silva da 06 August 2010 (has links)
Made available in DSpace on 2014-12-17T14:55:45Z (GMT). No. of bitstreams: 1 MelindaCSC_DISSERT.pdf: 967257 bytes, checksum: 22530a2989a1b62dc6a9df7bffa70ed3 (MD5) Previous issue date: 2010-08-06 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior / The electric energy is essential to the development of modern society and its increasing demand in recent years, effect from population and economic growth, becomes the companies more interested in the quality and continuity of supply, factors regulated by ANEEL (Ag?ncia Nacional de Energia El?trica). These factors must be attended when a permanent fault occurs in the system, where the defect location that caused the power interruption should be identified quickly, which is not a simple assignment because the current systems complexity. An example of this occurs in multiple terminals transmission lines, which interconnect existing circuits to feed the demand. These transmission lines have been adopted as a feasible solution to suply loads of magnitudes that do not justify economically the construction of new substations. This paper presents a fault location algorithm for multiple terminals transmission lines - two and three terminals. The location method is based on the use of voltage and current fundamental phasors, as well as the representation of the line through its series impedance. The wavelet transform is an effective mathematical tool in signals analysis with discontinuities and, therefore, is used to synchronize voltage and current data. The Fourier transform is another tool used in this work for extract voltage and current fundamental phasors. Tests to validate the location algorithm applicability used data from faulty signals simulated in ATP (Alternative Transients Program) as well as real data obtained from oscillographic recorders installed on CHESF s lines. / A energia el?trica ? indispens?vel para o desenvolvimento da sociedade moderna e sua crescente demanda nos ?ltimos anos, fruto dos crescimentos populacional e econ?mico, fez com que as concession?rias se tornassem mais comprometidas com a qualidade e a continuidade do fornecimento, fatores que s?o regulamentados pela ANEEL (Ag?ncia Nacional de Energia El?trica). Para que esses fatores sejam atendidos quando ocorre uma falta permanente no sistema, faz-se necess?ria, primeiramente, uma r?pida localiza??o do defeito causador da interrup??o da energia, o que n?o ? uma tarefa t?o simples devido ? complexidade dos sistemas atuais. Um exemplo disso ocorre nas linhas de transmiss?o com m?ltiplos terminais, que interligam circuitos existentes com objetivo de atender ? demanda. Nestas linhas, deriva??es para atender a cargas de porte que n?o justificam economicamente a constru??o de novas subesta??es s?o adotadas como medidas vi?veis para aliviar outros circuitos. Este trabalho prop?e um algoritmo de localiza??o de faltas que ? aplicado em linhas de transmiss?o com m?ltiplos terminais dois e tr?s terminais. O m?todo de localiza??o baseia-se no uso de fasores fundamentais de tens?o e corrente, bem como na representa??o da linha atrav?s de sua imped?ncia s?rie. A Transformada Wavelet ? uma ferramenta matem?tica eficaz na an?lise de descontinuidades de sinais e, por este motivo, ? utilizada na sincroniza??o dos dados de tens?o e corrente oriundos de faltas. A transformada de Fourier ? outra ferramenta utilizada neste trabalho para extra??o dos fasores fundamentais de tens?o e corrente. Para testar e validar a aplicabilidade do algoritmo de localiza??o, utilizaram-se dados de sinais faltosos simulados no ATP (Alternative Transients Program) e tamb?m dados reais obtidos de registradores oscilogr?ficos instalados em linhas da CHESF.
92

Detecção e classificação rápida de faltas em linhas de transmissão utilizando redes neurais artificiais / not available

Renan Giovanini 28 August 2000 (has links)
Proteger as linhas de transmissão é uma das tarefas mais importantes dentro dos sistemas elétricos de potência. Faltas em linhas de transmissão devem ser localizadas precisamente e extintas o mais rápido possível. Para tal, o esquema de proteção de linhas utiliza valores amostrados de correntes e tensões para a execução das tarefas de detecção, classificação e localização da falta. Neste esquema, grandezas trifásicas de corrente (IA, IB, IC) e tensão (VA, VB, VC) compõem as entradas do sistema. Após a detecção e classificação da falta, o relé efetua o cálculo da impedância aparente para a verificação da zona de proteção na qual a falta se insere (localização). Dentro deste contexto, a rápida detecção e a correta classificação da falta são passos fundamentais para a lógica de controle de um relé. Para a utilização de sistemas de proteção com alta velocidade de operação, o conjunto detector + classificador deve realizar uma decisão precisa do tipo de falta envolvida em menos de 10 ms após a ocorrência desta. Alguns métodos convencionais têm lidado com este problema, porém os tempos para estimação do tipo de falta são algumas vezes excessivamente longos. Este trabalho apresenta um novo sistema que provê uma rápida e confiável detecção e classificação de faltas através das medidas de valores de correntes trifásicas. O novo método utiliza-se da teoria de Redes Neurais Artificiais, baseada em dois diferentes tipos de redes (MLP e RBF), para a tarefa de detecção e classificação de faltas nos níveis de tempo requeridos para um moderno sistema de proteção. Um estudo comparativo em relação ao desempenho das redes mencionadas também foi realizado. Os testes efetuados para as redes dos tipos MLP e RBF mostraram que o sistema proposto foi capaz de detectar e classificar corretamente 100% dos casos estudados. Deve ainda ser ressaltado, que na maior parte dos casos (93% para a rede MLP e 84% para a rede RBF), o processo de detecção e classificação foi completado com no máximo 5 amostras de pós-falta (5ms). Isto demonstra a rapidez na tarefa de detecção e classificação embutida no método proposto, principalmente levando-se em consideração os tempos apresentados pelos métodos convencionais. / Transmission line protection is one of the major tasks for a power system. Transmission line faults must be located accurately and isolated as fast as possible. In order to perform this task, the power system protection system uses the three-phase currents (IA, IB, IC) and voltages (VA, VB, VC) to detect, classify and locate the fault. After detecting and classifying the fault, the relay calculates the apparent impedance to verify in which protection zone the fault is located. Taking this into account, precise and fast detection and classification methods are fundamental steps for the relay control algorithm. The combination detection + classification must carry out the correct response in less than 10 ms after the fault for a high-speed protection system. Some conventional methods have treated this problem but the time for a correct classification is sometimes excessively long. This work presents a fast and reliable new system for fault detection and classification using the three-phase current measurements. This new system is based on Artificial Neural Networks (RBF and MLP) for the detection and classification tasks. A comparative study involving both types of neural networks was done. Tests showed that the proposed system was able to correctly detect and classify 100% of the studied cases where the majority (93% of the cases for MLP net and 84% for RBF net) of them was done in up to 5 post-fault samples (5 ms). The afore-mentioned demonstrates the high speed of the new method for the detection and classification tasks when compared to the conventional ones.
93

Artificial neural network and Stockwell transform for fault location in transmission lines / Uso de redes neurais artificiais e transformada de Stockwell na localizaÃÃo de faltas em linhas de transmissÃo

Saulo Cunha AraÃjo de Souza 26 June 2015 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / This paper presents an automatic fault location method in transmission lines based on the Travelling Waves Theory (TWT) using the Stockwell Transform (ST) to determine the travelling waves propagation time and the dominant frequency of transient signals generated by faults. The method considers the case where there is no communication between terminals or loss of synchronism between the devices responsible for estimating the location of faults using, therefore, only data from one terminal. Single-phase faults only involving one of the phases and the earth area evaluated, which occur in the first half of a transmission line of unknown parameters. It is observed that the method (i) wasnât sensitive to fault resistance variations and inception angle and (ii) the obtained results presented errors between 0,10% and 5,82% for faults that occurred between 7km and 99km from the monitoring terminal. To improve the accuracy of estimating the fault location, an Artificial Neural Network (ANN) of the type MLP (Multi-Layer Perceptron) is designed, and trained with characteristics extracted from the faulty signals using ST. The ATP (Alternative Transient Program) software was adopted for simulation of a three phase transmission line which voltage signals were sampled at 200kHz. The simulations were performed exploring 1280 combinations of the following parameters: fault locations, fault resistances and inception angle. The method was developed using the software MATLABÂ. According to the obtained results, the combination of ST with ANN presented better results than the application of ST and TWT. Such improvement is highlighted for the estimation of fault location at greater distances from the monitoring terminal, with errors between 0,02% and 1,56% for faults that occurred between 7km and 99km from the monitoring terminal. / Este trabalho apresenta um mÃtodo automÃtico de localizaÃÃo de faltas em linhas de transmissÃo baseado na Teoria das Ondas Viajantes (TOV) utilizando a Transformada de Stockwell (TS) para determinaÃÃo dos tempos de propagaÃÃo das ondas viajantes e da frequÃncia dominante dos sinais transitÃrios gerados pelas situaÃÃes de falta. O mÃtodo considera o caso em que nÃo hà comunicaÃÃo entre terminais ou hà perda de sincronismo entre os equipamentos responsÃveis pela estimaÃÃo da localizaÃÃo das faltas utilizando, portanto, dados provenientes de apenas um terminal. Consideram-se faltas monofÃsicas envolvendo uma das fases e a terra, as quais ocorrem na primeira metade de uma linha de transmissÃo de parÃmetros desconhecidos. Observa-se que o mÃtodo (i) nÃo se mostrou sensÃvel a variaÃÃes de resistÃncia de falta e Ãngulo de incidÃncia e (ii) os resultados obtidos apresentam erros entre 0,10% e 5,82% para faltas que ocorreram entre 7km e 99km do terminal de monitoramento. Para a melhoria da precisÃo na estimaÃÃo da localizaÃÃo das faltas foi projetada uma Rede Neural Artificial (RNA) do tipo MLP (Multi-Layer Perceptron), treinada a partir de caracterÃsticas dos sinais faltosos extraÃdas atravÃs da TS. Foram utilizados os sinais trifÃsicos de tensÃo amostrados na frequÃncia de 200kHz gerados a partir de simulaÃÃes no software ATP (Alternative Transiente Program), no qual foram realizadas 1280 simulaÃÃes explorando diversas localizaÃÃes e resistÃncias de falta e Ãngulo de incidÃncia. O mÃtodo foi aplicado utilizando o software MATLABÂ. De acordo com os resultados obtidos, a combinaÃÃo da TS e RNA projetada apresentou melhores resultados do que a aplicaÃÃo da TS e TOV, destacando-se na estimaÃÃo da localizaÃÃo de faltas que ocorreram a maiores distÃncias do terminal de monitoramento, com erros entre 0,02% e 1,56% para faltas que ocorreram entre 7km e 99km do terminal de monitoramento.
94

Localização de faltas em linhas de transmissão utilizando a teoria de ondas viajantes e transformada Wavelet / Fault Location in Transmission Lines Using Traveling Waves and Wavelet Transform Theory

Murilo da Silva 05 November 2003 (has links)
Este trabalho traz a aplicação da transformada wavelet (TW) para analisar os transitórios de alta freqüência em um sistema de transmissão causados por uma falta sustentada, com o objetivo de se determinar a precisa localização da mesma. A TW, ferramenta matemática empregada neste trabalho, é uma transformação linear muito parecida com a transformada de Fourier, com uma importante diferença: ela permite a localização no tempo de diferentes componentes de freqüência de um dado sinal. Esta localização permite a detecção no tempo da ocorrência de distúrbios abruptos, tais como os transitórios ocasionados por situações de faltas. Os sinais de ondas viajantes geradas pela ocorrência da falta aparecem como distúrbios superpostos aos sinais de freqüência fundamental que são registrados pelos relés. Processando-se estes sinais pelo emprego da TW, esta pode revelar o tempo de propagação dos sinais analisados entre o ponto de ocorrência do distúrbio e a localização física do relé. Conseqüentemente, dispondo-se do intervalo de tempo entre as ondas sobre uma dada linha de transmissão, a distância do ponto de falta pode então ser facilmente determinada, sendo esta a filosofia adotada neste trabalho. O problema delineado é abordado através da implementação prática de um algoritmo computacional. Nesta implementação, o usuário pode escolher a técnica de localização a ser empregada, utilizando-se de dados registrados em um ou em ambos os terminais da linha, conforme a sua necessidade e/ou disponibilidade dos recursos necessários. Com o objetivo de testar e validar a aplicabilidade do algoritmo de localização de faltas, utilizou-se de dados de sinais faltosos obtidos através de simulações do software ATP (Altenative Transients Program), levando-se em conta vários tipos de falta em diferentes localizações ao longo da linha, com diferentes ângulos de incidência, resistências de falta, freqüência de amostragem do sinal, etc. Também foi verificada a influência do acoplamento mútuo em caso de circuitos duplos de transmissão. Os resultados alcançados pelo algoritmo são promissores e demonstram uma ótima precisão e aplicabilidade do método proposto. / This work presents a wavelet transform (WT) application to analyze the high frequency transients in a transmission line caused by a fault, with the purpose of determining its accurate location. The WT is very similar to Fourier Transform (FT), with an important difference: it allows the time determination of different frequency components of a signal. This skill allows the detection of the time of the disturbance occurrence, such as fault transients. The traveling waves generated by the fault occurrence appear as superimposed disturbances on the power frequency signals recorded by the relay. By processing these signals using the WT, the propagation time between the fault point and the relay location can be determined. Consequently, the distance of the fault point can be easily calculated. The delineated problem is boarded through the practical implementation of a computational algorithm. In this implementation, the user can choose the location technique to be employee, using data registered in one or both the terminals of the line, according to the necessity and/or availability of the data. In order to evaluate the applicability of the proposed scheme, the simulation of the transmission line in a faulty condition was utilized. This work makes use of a digital simulator of a faulted EHV (Extra High Voltage) transmission lines known as Alternative Transients Program (ATP). A typical transmission line from CESP (Companhia Energética de São Paulo) were utilized. The simulated data obtained was very close to that found in practice. This study takes into account single phase to ground faults, phase-to-phase faults, phase-phase to ground and three phase faults. The data set was composed of various fault situations considering different fault locations, fault resistances and fault inception angles. The influence of the sampled rate used was also verified as well as the mutual coupling in case of double transmission circuits. The test results reached for the algorithm are promising and demonstrate a highly satisfactory degree of accuracy and applicability of the proposed method.
95

An architecture to resilient and highly available identity providers based on OpenID standard / Uma arquitetura para provedores de identidade resistente e altamente disponíveis com base no padrão OpenID

Cunha, Hugo Assis 26 September 2014 (has links)
Submitted by Lúcia Brandão (lucia.elaine@live.com) on 2015-07-14T15:58:20Z No. of bitstreams: 1 Dissertação - Hugo Assis Cunha.pdf: 4753834 bytes, checksum: 4304c038b5fb3c322af4b88ba5d58195 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-20T14:08:11Z (GMT) No. of bitstreams: 1 Dissertação - Hugo Assis Cunha.pdf: 4753834 bytes, checksum: 4304c038b5fb3c322af4b88ba5d58195 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-07-20T14:12:26Z (GMT) No. of bitstreams: 1 Dissertação - Hugo Assis Cunha.pdf: 4753834 bytes, checksum: 4304c038b5fb3c322af4b88ba5d58195 (MD5) / Made available in DSpace on 2015-07-20T14:12:26Z (GMT). No. of bitstreams: 1 Dissertação - Hugo Assis Cunha.pdf: 4753834 bytes, checksum: 4304c038b5fb3c322af4b88ba5d58195 (MD5) Previous issue date: 2014-09-26 / Não Informada / Quando se trata de sistemas e serviços de autenticação seguros, há duas abordagens principais: a primeira procura estabelecer defesas para todo e qualquer tipo de ataque. Na verdade, a maioria dos serviços atuais utilizam esta abordagem, a qualsabe-sequeéinfactívelefalha. Nossapropostautilizaasegundaabordagem, a qual procura se defender de alguns ataques, porém assume que eventualmente o sistema pode sofrer uma intrusão ou falha e ao invés de tentar evitar, o sistema simplesmente as tolera através de mecanismos inteligentes que permitem manter o sistema atuando de maneira confiável e correta. Este trabalho apresenta uma arquiteturaresilienteparaserviçosdeautenticaçãobaseadosemOpenIDcomuso deprotocolosdetolerânciaafaltaseintrusões, bemcomoumprotótipofuncional da arquitetura. Por meio dos diversos testes realizados foi possível verificar que o sistema apresenta um desempenho melhor que um serviço de autenticação do OpenID padrão, ainda com muito mais resiliência, alta disponibilidade, proteção a dados sensíveis e tolerância a faltas e intrusões. Tudo isso sem perder a compatibilidade com os clientes OpenID atuais. / Secure authentication services and systems typically are based on two main approaches: the first one seeks to defend itself of all kind of attack. Actually, the major current services use this approach, which is known for present failures as well as being completely infeasible. Our proposal uses the second approach, which seeks to defend itself of some specific attacks, and assumes that eventually the system may suffer an intrusion or fault. Hence, the system does not try avoiding the problems, but tolerate them by using intelligent mechanisms which allow the system keep executing in a trustworthy and safe state. This research presents a resilient architecture to authentication services based on OpenID by the use of fault and intrusion tolerance protocols, as well as a functional prototype. Through the several performed tests, it was possible to note that our system presents a better performance than a standard OpenID service, but with additional resilience, high availability, protection of the sensitive data, beyond fault and intrusion tolerance, always keeping the compatibility with the current OpenID clients.
96

Controle tolerante a falhas de um sistema de propulsão de hexacópteros

Santos, Murillo Ferreira dos 30 July 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-25T17:55:23Z No. of bitstreams: 1 murilloferreiradossantos.pdf: 10926905 bytes, checksum: fd28a8c6e03bce5e40e5620a6bbf1666 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-26T12:22:42Z (GMT) No. of bitstreams: 1 murilloferreiradossantos.pdf: 10926905 bytes, checksum: fd28a8c6e03bce5e40e5620a6bbf1666 (MD5) / Made available in DSpace on 2017-04-26T12:22:42Z (GMT). No. of bitstreams: 1 murilloferreiradossantos.pdf: 10926905 bytes, checksum: fd28a8c6e03bce5e40e5620a6bbf1666 (MD5) Previous issue date: 2014-07-30 / Este trabalho tem o objetivo de desenvolver o controle tolerante a falhas de um sistema de propulsão de hexacópteros, visando mante-lo em condições de voo. Inicialmente, apresenta-se a modelagem do sistema, abordando o modelo cinemático e dinâmico da aeronave para a simulação e controle do sistema onde as forças gravitacionais e de propulsão são consideradas. Falhas nos sistemas de propulsão são inseridas para que quando detectadas, o sistema seja operado com outra sintonia de controladores PID, mantendo-o em condições de voo. Por fim, os resultados são simulados e analisados onde através dos índices de desempenho IAE, ISE e ITSE seja possível realizar um estudo de viabilidade do tempo limite que uma técnica de detecção e identificação de falhas terá disponível para localizar qual sistema de propulsão se encontra com problemas. Os resultados foram satisfatórios mostrando ser uma técnica possível de se implementada na aeronave desenvolvida. / This dissertation aims to develop the fault tolerant control of a propulsion system of hexacopters, which intends to keep it in good flight conditions. Initially, it’s presented the modeling of the system, considering the kinematic and dynamic model of the aircraft where the gravitational and propulsion forces are considered. Failures in propulsion systems are inserted to the system and when detected, the system can be operated with the new PID tuning, keeping it in flight. Finally, the results are simulated and analyzed using performance indices as IAE, ISE and ITSE, making possible to perform the feasibility study of the time limit that a technique for detecting and identifying faults have available to find which propulsion system meets problems. The results were satisfactory showing to be a possible technique to be implemented in the aircraft developed.
97

Processador inteligente de alarmes e modelos de programação matemática para diagnóstico de faltas em sistemas elétricos de potência / Intelligent alarm processor and mathematical programming models for fault diagnosis in electrical power systems

Oliveira, Aécio de Lima 24 June 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This thesis proposes an Intelligent Alarm Processor for fault diagnosis in electrical power systems. The objective is to develop a methodology for automatic fault analysis using reported alarms from Supervisory Control and Data Acquisition (SCADA) to allow the use of diagnosis systems in large power systems. The proposal can be used in real-time decision support systems to assist control center‟s operators during the decision-making after unscheduled contingencies with relevant information to power system restoration. This work expects to contribute to the development of advanced alarm management logics that allow modifying the chronological sequence of reported alarms, event mapping and the generation of operating patterns of protection systems according to topology network. Still, mathematical programming models have been formulated as a parsimonious set covering problem to fault section estimation and identification of protective devices with improper operation. Among these models, it stands out the model that deals with integrated analysis of reported alarms, events and diagnosis that better explain the alarms. The proposed approach has been tested in different portions of the Southern Brazilian power system. The results show that alarm processing allows the practical implementation of intelligent diagnosis methods in existing supervisory systems. The proposed diagnosis methods show better performance and accurate solutions than other methods presented in literature. / Esta tese propõe um Processador Inteligente de Alarmes para diagnóstico de faltas em sistemas elétricos de potência. O objetivo é desenvolver uma metodologia para a análise automática de faltas a partir dos alarmes reportados no sistema de supervisão e aquisição de dados (SCADA) que possibilite o uso de métodos de diagnóstico em sistemas de potência de grande porte. Essa proposta pode ser empregada em sistemas de apoio à decisão em tempo real, que auxiliem operadores de centros de controle do sistema (COS) na tomada de decisão após desligamentos não programados, com informações pertinentes para o restabelecimento do sistema. O trabalho espera contribuir com o desenvolvimento de lógicas avançadas de gerenciamento de alarmes que possibilitem a reordenação cronológica dos alarmes reportados, o mapeamento dos eventos e a geração de padrões de funcionamento de sistemas de proteção de acordo à topologia da rede. Além disso, os modelos de programação matemática foram formulados como um problema de recobrimento de conjuntos parcimonioso, para estimação da seção em falta e identificação dos dispositivos de proteção com atuação indevida. Dentre esses modelos, destaca-se o modelo que analisa, de forma integrada, os alarmes reportados e determina os eventos e diagnósticos que melhor explicam os alarmes. A abordagem proposta foi testada em diferentes porções do sistema sul do sistema interligado nacional (SIN). Os resultados mostram que as rotinas desenvolvidas para o processamento de alarmes permite a implantação prática de métodos inteligentes de diagnóstico em sistemas supervisórios existentes. Os métodos propostos para diagnóstico de faltas mostraram desempenhos e precisão nos resultados superiores a outros métodos presentes na literatura.
98

Proposta de um sistema híbrido composto por redes neurais artificiais e algorítmos genéticos para o tratamento de alarmes e o diagnóstico de faltas em sistemas elétricos de potência / Proposal of a hybrid system composed of artificial neural networks and genetic algorithms for the treatment of alarms, and fault diagnosis in electrical power system

Toller, Marcelo Brondani 18 February 2011 (has links)
This work proposes a hybrid system for alarm processing and fault diagnosis in electrical networks which use two methods of computational intelligence: Generalized Regression Neural Network and Genetic Algorithms. The neural network has the function of processing the set of received alarms and present as a response the characteristic(s) event(s), using for this, an elaborated knowledge based on the functional diagrams for protection and interviews with operators. Six modules were implemented for different neural components of a test system, according to their protection schemes. The output of these modules is used as input to the GA which has to do a combined analysis along with its database and provide the operator with the main protective components involved in the incident, as well as the probable causes of defects and actions to be taken in order to return the system in the shortest possible time and greater safety. For average inserted random errors of 0%, 7,73%, 15,46% and 23,19% in the received alarms, the system was able to diagnoses correctly in 100%, 93,60%, 74,26% and 48,07% of the cases respectively. It was found that the genetic algorithm improved the results obtained by neural network with good capability of generalization and condition to present multiple solutions, and the response time of the hybrid system was acceptable to the under consideration problem. / O presente trabalho propõe um sistema híbrido para processamento de alarmes e diagnóstico de faltas em redes elétricas com a utilização de dois métodos de inteligência computacional: Generalized Regression Neural Network e Algoritmos Genéticos. A rede neural tem a função de processar o conjunto de alarmes reportados e apresentar como resposta o evento(s) característico(s), utilizando-se, para isso, de um conhecimento elaborado com base nos diagramas funcionais da proteção e entrevista com operadores. Foram implementados seis módulos neurais para diferentes componentes de um sistema teste, de acordo com os seus respectivos esquemas de proteção. A saída destes módulos é utilizada como entrada para o AG que deve fazer uma análise combinatória juntamente com sua base de dados e apresentar ao operador os principais componentes de proteção envolvidos na incidência, bem como as prováveis causas do defeito e ações a serem tomadas de forma a restabelecer o sistema no menor tempo possível e com maior segurança. Para erros aleatórios médios inseridos de 0%, 7,73%, 15,46% e 23,19% nos alarmes reportados, o sistema se mostrou capaz de diagnosticar corretamente em respectivamente 100%, 93,60%, 74,26% e 48,07% dos casos. Verificou-se que o algoritmo genético melhorou os resultados obtidos pela rede neural, apresentando boa capacidade de generalização e condições de apresentação de múltiplas soluções, sendo o tempo de resposta do sistema híbrido aceitável para o problema tratado.
99

Desenvolvimento de modelos matemáticos para o diagnóstico de falta em sistemas de transmissão de energia elétrica /

Figueroa Escoto, Esau January 2020 (has links)
Orientador: Fábio Bertequini Leão / Resumo: Este trabalho apresenta modelos de programação não linear e linear inteira binária como novos métodos para resolver o problema de diagnóstico de faltas em sistemas de transmissão de energia elétrica. Os modelos de otimização são desenvolvidos com base no conjunto de coberturas mínimas e possui como restrições as equações que descrevem a lógica e a filosofia de proteção empregadas por empresas de energia elétrica. As equações de restrições modelam a associação dos alarmes dos relés de proteção informados pelo sistema de supervisão e aquisição de dados (SCADA) com os estados esperados das funções dos relés de proteção. Os modelos de programação matemática realizam o diagnóstico de falta em uma única etapa, identificando a seção em falta através da análise dos estados dos disjuntores e das funções de proteção associadas a cada equipamento do sistema elétrico. O modelo proposto é um problema muito complexo de programação não linear inteira binária, portanto é reformulado como outro problema, em que algumas expressões são linearizadas, o que resulta em um modelo matemático de programação linear inteiro binário. A solução ótima obtida pelo modelo proposto é encontrada utilizando solvers comerciais de programação matemática. Os resultados obtidos mostram eficiência e robustez do modelo matemático. Na literatura, o problema de diagnóstico de falta é resolvido principalmente por técnicas heurísticas, portanto, o método proposto é inovador. / Doutor
100

Estudo da capacidade LVRT de sistemas eólicos com DFIG durante a ocorrência de faltas elétricas /

Costa, Christielly Fernandes da January 2020 (has links)
Orientador: André Luiz Andreoli / Resumo: Nos últimos anos, questões relacionadas ao meio ambiente, principalmente, ao uso de combustíveis fósseis e à emissão de gases poluentes na atmosfera, ganharam grande destaque internacional. Com os avanços da comunidade científica e o aumento no preço do petróleo no começo da década de 1970, o uso de fontes renováveis, não poluentes e limpas teve grande investimento por parte de diversos países. Nesse contexto, a geração eólica vem se destacando como uma das mais promissoras, especialmente devido a sua viabilidade econômica e ao seu rápido desenvolvimento tecnológico. Entre as diferentes topologias utilizadas nos sistemas de geração eólica, destaca-se a configuração elaborada para operação em velocidade variável, que emprega o gerador de indução duplamente alimentado (DFIG), associado ao conversor eletrônico back-to-back para controle de sua operação. Como principais vantagens da utilização do DFIG, destacam-se sua maior eficiência na conversão de energia, menor estresse mecânico do rotor, controle independente de potência ativa e reativa limitada a valores típicos de 30% da potência nominal. Por outro, sabe-se que, durante a ocorrência de um distúrbio, as correntes do rotor podem atingir altas magnitudes e causar danos ao conversor. Além disso, sobretensões no capacitor do elo CC ocorrem devido à perda de capacidade de transferência de energia do conversor do lado da rede. Entretanto, os aerogeradores podem ser requisitados a permanecerem em funcionamento mesmo durante uma fa... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last years, issues related to the environment, especially the use of fossil fuels and the emission of polluting gases into the atmosphere, have gained great international prominence. With the advances of scientific community and the increase of the oil price in the beginning of the 1970s, the use of renewable, non-polluting and clean sources had a great investment by several countries. In this context, wind generation has stood out as one of the most promising, especially due to its economic viability and its fast technological development. Among the different topologies used in wind generation systems, the configuration developed for operation at variable speed is highlighted, which employs the doubly-fed induction generator (DFIG) associated with back-to-back electronic converter to control its operation. The main advantages of using DFIG include its greater efficiency in energy conversion, less mechanical rotor stress, independent control of active and reactive power limited to typical values of 30% of the rated power. On the other hand, it is known that, during the occurrence of a disturbance, such as an electrical fault, the rotor currents can reach high magnitudes in order to damage the rotor side converter. In addition, overvoltages in the DC link capacitor occur due to the loss of power transfer capacity on grid side converter. However, wind turbines may be required to main in operation even during a fault, in addition to contributing the restoration of voltage... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0389 seconds