• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 36
  • 8
  • 6
  • 4
  • 3
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 149
  • 149
  • 149
  • 149
  • 59
  • 55
  • 25
  • 16
  • 15
  • 14
  • 13
  • 13
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Wireless Power Transfer For Space Applications: System Design And Electromagnetic Compatibility Compliance Of Radiated Emissions

Vazquez, Ramos Gabriel 01 January 2012 (has links)
This dissertation evaluates the possibility of wireless power transfer (WPT) systems for space applications, with an emphasis in launch vehicles (rockets). After performing literature review for WPT systems, it was identified that magnetic resonance provides the more suited set of characteristics for this application. Advanced analysis, simulation and testing were performed to magnetic resonance WPT systems to acquire system performance insight. This was accomplished by evaluating/varying coupling configuration, load effects and magnetic element physical characteristics (i.e. wire material, loop radius, etc.). It was identified by analysis, circuit simulation and testing that the best coupling configuration for this application was series-series and series-shunt with Litz wire loop inductors. The main concern identified for the implementation of these systems for space applications was radiated emissions that could potentially generate electromagnetic interference (EMI). To address this EMI concern, we developed the Electromagnetic Compatibility Radiated Emissions Compliance Design Evaluation Approach for WPT Space Systems. This approach systematically allocates key analyses, simulations and tests procedures to predict WPT EMC compliance to NASA’s EMC standard Mil-Std-461E/F. Three prototype/magnetic elements were successfully assessed by implementing the WPT EMC design approach. The electric fields intensity generated by the WPT prototypes/magnetic elements tested were: 30.02 dBµV/m, 28.90 dBµV/m and 82.13 dBµV/m (requirement limit: 140 dBµV/m). All three prototypes successfully transferred power wirelessly and successfully met the NASA EMC requirements.
142

Quantitative ultrasound in transverse transmission for bone quality assessment and monitoring fracture healing

Rohrbach, Daniel 04 September 2013 (has links)
Osteoporose und gestörte Heilungsverläufe von Knochenbrüchen verursachen immer noch beachtliche klinische Komplikationen. Ein vielversprechender Ansatz für die nichtinvasive und nichtionisierende Abschätzung des Frakturrisikos und der Bildgebung von Frakturheilung ist quantitativer Ultraschall (QUS). Dennoch liegt die derzeitige Akzeptanz für die Knochenqualitätsabschätzung noch weit hinter herkömmlichen röntgenbasierten Anwendungen. Es wurden akustische Mikroskopie und Synchrotronstrahlen-Mikrotomographie für die Anatomie und altersabhängige Erfassung von strukturellen und elastischen Variationen auf der mikroskopischen Ebene von humanen Femora verwendet. Die gewonnenen Daten dienten als Grundlage für die Erstellung mikromechanischer Modelle von Knochen für numerische Simulationen der Schallausbreitung im humanen Femurhals. Dabei wurde der Aufbau eines US-basierten Femur-Scanners in transversaler Transmission (TT) nachempfunden. Im letzten Abschnitt der Arbeit wurde QUS in TT in in vitro Experimenten am Rattenfrakturmodell auf eine Anwendung für die Bildgebung der Frakturheilung getestet. Die Studien konnten zeigen, dass ein Großteil der adaptiven Fähigkeiten von Knochen auf mikroskopischer Ebene auf eine Kombination von extrazellulärer Matrixelastizität und Gewebeporosität zurückzuführen ist. Die Simulationen des zweiten Teils konnten die Existenz von geführten Wellen im humanen Femurhals bestätigen. Die sensitive Abhängigkeit von US-parametern von frakturrelevanten Knocheneigenschaften zeigt das hohe Potential von QUS für die Frakturrisikoabschätzung. Der zweite Teil der Arbeit konnte erfolgreich die Möglichkeit von QUS in TT zur Diskriminierung von zeitigen Heilungsstadien demonstrieren. Zusammenfassend bestätigt die Studie das hohe Potential von QUS für die Frakturrisikoabschätzung und die Bildgebung der Frakturheilung. / Osteoporosis and impaired bone healing are of high relevance. A promising non-invasive, non-ionizing candidate for fracture risk prediction and monitoring fracture healing is quantitative ultrasound (QUS). However, the acceptance of QUS for bone quality assessment is still not comparable to X-ray based methods. Scanning acoustic microscopy (SAM) and Synchrotron Radiation micro-computer tomography (SRµCT) has been used to investigate anatomical and age dependent variations of micro elastic, structural and mineralization parameters at the tissue level of human femoral bone. Femoral neck models were created based on these data for numerical sound propagation simulations emulating a transverse transmission (TT) setup of an in vivo QUS prototype. In the last part of the project the TT approach has been tested in ex vivo experiments in a rat healing model. The power of QUS, to discriminate two early healing stages has been compared to µCT measurements at the same specimens. It was found that the major contributor to bone adaptation is related to a combination of extracellular matrix elasticity and tissue porosity. It is hypothesized that these parameters are likely to have a considerable impact on the reliability of in silico models. The simulations of the second part confirmed the existence of guided wave propagation in the cortical shell and a high dependency of US parameters on fracture relevant bone properties. The results demonstrate the high potential for bone fracture risk prediction at the femoral neck using QUS. Finally, it was successfully demonstrated that early healing stage discrimination of QUS in TT was superior compared to µCT. In summary these investigations not only show the importance for a precise estimation of micro mechanical properties for numerical modelling but also demonstrate the feasibility and high potential of QUS for bone quality assessment and monitoring of fracture healing.
143

Nanopinces optiques à base de modes de Bloch lents en cavité / SlowBloch mode nanotweezers

Gerelli, Emmanuel 13 December 2012 (has links)
Ce travail de thèse s’inscrit dans les efforts actuellement réalisés, pour améliorer l’efficacité des pinces optiques conventionnelles qui permettent de manipuler sans contact des objets de quelques dizaines de nanomètres à quelques dizaines de micromètres avec une extrême précision et trouvent de nombreuses applications en biophysique et sciences de colloïdes.L’objectif de cette thèse a été d’explorer une nouvelle approche pour la réalisation de Nanopinces Optiques. Elle s’appuie sur l’utilisation de cavités à cristaux photoniques à modes de Bloch lents. Ces cavités peuvent être efficacement et facilement excitées par un faisceau Gaussien à incidence normale. Contrairement aux pinces optiques conventionnelles, des objectifs à faibles ouvertures numériques peuvent être utilisés. Les performances attendues en termes de piégeage vont bien au-delà de limitations imposées par la limite de diffraction pour les pinces conventionnelles. Ce travail démontre expérimentalement l’efficacité de l’approche. Cette thèse comporte deux parties principales. Dans un premier temps, il a fallu monter un banc expérimental pour mener nos études. Nous avons construit un banc optique, interfacé les instruments, et développé des applications logicielles pour analyser les données. Deux éléments importants ont présidé à sa construction : - Le développement d’un système optique permettant d’exciter les nanostructures photoniques - la conception d’un système d’imagerie pour suivre les nanoparticules. La seconde partie de ce travail a porté sur la mise en évidence du piégeage optique à l’aide de nanostructure à base de cristaux photonique. Nous avons d’abord montré que même des cavités possédant des coefficients de qualités modérés (quelques centaines) permettait d’obtenir des pièges optiques dont l’efficacité est d’un ordre de grandeur supérieur à celui de pinces conventionnels. Fort de ce résultat, nous avons exploré un nouveau type de cavité à cristaux photoniques s’appuyant sur une approche originale : des structures bi-périodiques. Nous avons montré qu’à l’aide de cette approche des facteurs de qualités de l’ordre de plusieurs milliers étaient facilement atteignable. A l’aide de ces nouvelles structures, nous sommes arrivés aux résultats le plus important de ce travail : le piégeage de nanoparticules de 250nm de rayon avec une puissance optique incidente de l’ordre du milliwatt. Une analyse fine du mouvement de la nanoparticule, nous a permis de trouver la signature du mode de Bloch lent. / This thesis aims at improving the efficiency of conventional optical tweezers (cOT). They allow to manipulate objects with dimension from a few tens of nanometer to a few tens of micrometers with a high accuracy and without contact. This has numerous applications in biophysics and colloidal science. This thesis investigates a new approach for optical nanotweezers. It uses a photonic crystal (PC) cavity which generates a slow Bloch mode. This cavity can be effectively and easily excited with a Gaussian beam at the normal incidence. Contrarily to cOT, objective with a small numerical aperture can be used. The expected performances in terms of trapping go well beyond the diffraction limit of cOT. This work demonstrates experimentally the efficacy of approach. This thesis is divided in two main sections. First, we had to set up an experimental bench to carry out to our study. We built the optical bench interface instruments and develop programs to analyze the data. Two essential elements have been considered: - The development of the optical system allowing the excitation of the photonics nanostructure. - The design an imaging system to track nanoparticles. Second, we have focus on the demonstration of the optical trapping. We started by with a low Q factor (few hundred) cavity. Trapping efficiency of an order of magnitude higher than cOT has been demonstrated. Then, we have explored a new king of PC cavity based on double period structure. We show that thanks to this approach high Q factor of several thousand are easily reached. With this structure, we managed to trap 250nm polystyrene beads, with an optical power of the order of a milliwatt. A deep analysis of the nanoparticle trajectories allowed us to find a slow Bloch mode signature.
144

Simulation of Engineered Nanostructured Thin Films

Cheung, JASON 01 April 2009 (has links)
The invention of the Glancing Angle Deposition (GLAD) technique a decade ago enabled the fabrication of nanostructured thin films with highly tailorable structural, electrical, optical, and magnetic properties. Here a three-dimensional atomic-scale growth simulator has been developed to model the growth of thin film materials fabricated with the GLAD technique, utilizing the Monte Carlo (MC) and Kinetic Monte Carlo (KMC) methods; the simulator is capable of predicting film structure under a wide range of deposition conditions with a high degree of accuracy as compared to experiment. The stochastic evaporation and transport of atoms from the vapor source to the substrate is modeled as random ballistic deposition, incorporating the dynamic variation in substrate orientation that is central to the GLAD technique, and surface adatom diffusion is modeled as either an activated random walk (MC), or as energy dependent complete system transitions with rates calculated based on site-specific bond counting (KMC). The Sculptured Nanostructured Film Simulator (SNS) provides a three-dimensional physical prediction of film structure given a set of deposition conditions, enabling the calculation of film properties including porosity, roughness, and fractal dimension. Simulations were performed under various growth conditions in order to gain an understanding of the effects of incident angle, substrate rotation, tilt angle, and temperature on the resulting morphology of the thin film. Analysis of the evolution of film porosity during growth suggests a complex growth dynamic with significant variations with changes in tilt or substrate motion, in good agreement with x-ray reflectivity measurements. Future development will merge the physical structure growth simulator, SNS, with Finite-Difference Time-Domain (FDTD) electromagnetics simulation to allow predictive design of nanostructured optical materials. / Thesis (Master, Physics, Engineering Physics and Astronomy) -- Queen's University, 2009-03-31 13:22:11.843
145

Parametric Interaction in Josephson Junction Circuits and Transmission Lines

Mohebbi, Hamid Reza 06 November 2014 (has links)
This research investigates the realization of parametric amplification in superconducting circuits and structures where nonlinearity is provided by Josephson junction (JJ) elements. We aim to develop a systematic analysis over JJ-based devices toward design of novel traveling-wave Josephson parametric amplifiers (TW-JPA). Chapters of this thesis fall into three categories: lumped JPA, superconducting periodic structures and discrete Josephson transmission lines (DJTL). The unbiased Josephson junction (JJ) is a nonlinear element suitable for parametric amplification through a four-photon process. Two circuit topologies are introduced to capture the unique property of the JJ in order to efficiently mix signal, pump and idler signals for the purpose of signal amplification. Closed-form expressions are derived for gain characteristics, bandwidth determination, noise properties and impedance for this kind of parametric power amplifier. The concept of negative resistance in the gain formulation is observed. A design process is also introduced to find the regimes of operation for gain achievement. Two regimes of operation, oscillation and amplification, are highlighted and distinguished in the result section. Optimization of the circuits to enhance the bandwidth is also carried out. Moving toward TW-JPA, the second part is devoted to modelling the linear wave propagation in a periodic superconducting structure. We derive closed-form equations for dispersion and s-parameters of infinite and finite periodic structures, respectively. Band gap formation is highlighted and its potential applications in the design of passive filters and resonators are discussed. The superconducting structures are fabricated using YBCO and measured, illustrating a good correlation with the numerical results. A novel superconducting Transmission Line (TL), which is periodically loaded by Josephson junctions (JJ) and assisted by open stubs, is proposed as a platform to realize a traveling-wave parametric device. Using the TL model, this structure is modeled by a system of nonlinear partial differential equations (PDE) with a driving source and mixed-boundary conditions at the input and output terminals, respectively. This model successfully emulates parametric and nonlinear microwave propagation when long-wave approximation is applicable. The influence of dispersion to sustain three non-degenerate phased-locked waves through the TL is highlighted. A rigorous and robust Finite Difference Time Domain (FDTD) solver based on the explicit Lax-Wendroff and implicit Crank-Nicolson schemes has been developed to investigate the device responses under various excitations. Linearization of the wave equation, under small-amplitude assumption, dispersion and impedance analysis is performed to explore more aspects of the device for the purpose of efficient design of a traveling-wave parametric amplifier. Knowing all microwave characteristics and identifying different regimes of operation, which include impedance properties, cut-off propagation, dispersive behaviour and shock-wave formation, we exploit perturbation theory accompanied by the method of multiple scale to derive the three nonlinear coupled amplitude equations to describe the parametric interaction. A graphical technique is suggested to find three waves on the dispersion diagram satisfying the phase-matching conditions. Both cases of perfect phase-matching and slight mismatching are addressed in this work. The incorporation of two numerical techniques, spectral method in space and multistep Adams-Bashforth in time domain, is employed to monitor the unilateral gain, superior stability and bandwidth of this structure. Two types of functionality, mixing and amplification, with their requirements are described. These properties make this structure desirable for applications ranging from superconducting optoelectronics to dispersive readout of superconducting qubits where high sensitivity and ultra-low noise operation is required.
146

Ανάπτυξη μη επεμβατικών συστημάτων υπερθερμίας για θεραπευτικές εφαρμογές εγκεφάλου

Γουζούασης, Ιωάννης 20 October 2010 (has links)
Η υπερθερμία αποτελεί μια επικουρική μέθοδο θεραπείας του καρκίνου και η βιοϊατρική έρευνα τις τελευταίες δεκαετίες, με σκοπό την εκμετάλλευση και την ανάδειξη των ιδιοτήτων της μεθόδου, στοχεύει στην εφαρμογή της στην κλινική πράξη. Μια προσπάθεια με παρόμοιο σκοπό γίνεται τα τελευταία χρόνια στο Εργαστήριο Μικροκυμάτων και Οπτικών Ινών (ΕΜΟΙ) της σχολής Ηλεκτρολόγων Μηχανικών και Μηχανικών Υπολογιστών (ΗΜΜΥ) του Εθνικού Μετσόβιου Πολυτεχνείου, όπου έχει σχεδιαστεί και κατασκευαστεί ένα μικροκυματικό σύστημα υπερθερμίας. Το προτεινόμενο σύστημα ενσωματώθηκε σε ένα τρισδιάστατο σύστημα παθητικής μικροκυματικής ραδιομετρικής απεικόνισης (ΜiRaIS), το οποίο παρέχει τη δυνατότητα παρακολούθησης των μεταβολών της θερμοκρασίας και της αγωγιμότητας της υπό εξέταση περιοχής σε πραγματικό χρόνο και μελετήθηκε και κατασκευάστηκε στα πλαίσια παλαιότερης διδακτορικής διατριβής στο ίδιο εργαστήριο της σχολής ΗΜΜΥ. Στην παρούσα διδακτορική διατριβή γίνεται η θεωρητική και πειραματική μελέτη του προτεινόμενου συστήματος υπερθερμίας. Η αρχή λειτουργίας του συστήματος είναι όμοια με εκείνη του MiRaIS και βασίζεται στη χρήση μιας ελλειψοειδούς αγώγιμης κοιλότητας για εστίαση της ακτινοβολίας επιλεκτικά στους ιστούς που χρήζουν θεραπείας. Ο ανακλαστήρας για εστίαση που κατασκευάστηκε και χρησιμοποιήθηκε στην πειραματική διαδικασία, βελτιώνει την εργονομία του συστήματος, διατηρώντας παράλληλα της ιδιότητες εστίασης του πρωτότυπου ελλειψοειδούς. Στα πλαίσια της παρούσας διατριβής πραγματοποιήθηκε αρχικά η θεωρητική μελέτη και μοντελοποίηση της διάταξης με σκοπό την εξακρίβωση των ιδιοτήτων εστίασης του συστήματος και στη συνέχεια επιχειρήθηκε η βελτίωση των ιδιοτήτων αυτών με χρήση διατάξεων διηελκτρικών υλικών, καθώς και πειραματικές μετρήσεις του συνολικού συστήματος υπερθερμίας-μικροκυματικής ραδιομετρίας. Η θεωρητική ηλεκτρομαγνητική μελέτη του συστήματος έγινε με τη χρήση ενός εμπορικά διαθέσιμου υπολογιστικού πακέτου προσομοίωσης (XFdtd, Remcom Inc.), το οποίο χρησιμοποιεί τη μέθοδο των πεπερασμένων διαφορών στο πεδίο του χρόνου για την επίλυση ηλεκτρομαγνητικών προβλημάτων. Ερευνώνται τρεις διατάξεις διηλεκτρικών υλικών με σκοπό τη βελτίωση των ιδιοτήτων εστίασης του συστήματος, οι οποίες επικεντρώνονται στη μελέτη του βάθους διείσδυσης της ακτινοβολίας και της χωρικής διακριτικής ικανότητας. Τα υλικά τοποθετούνται είτε στο εσωτερικό του ελλειψοειδούς είτε γύρω από το μοντέλο κεφαλιού ως στρώματα προσαρμογής, με σκοπό την επίτευξη βηματικής αλλαγής της διηλεκτρικής σταθεράς στη διεπιφάνεια αέρα-μοντέλο ανθρώπινου κεφαλιού. Τα αποτελέσματα καταδεικνύουν τα πλεονεκτήματα από τη χρήση των διηλεκτρικών υλικών, καθώς παρουσιάζεται βελτίωση και στις δυο παραμέτρους των ιδιοτήτων εστίασης, ανάλογα με τη διάταξη που χρησιμοποιείται, τη θέση του μοντέλου κεφαλιού στο εσωτερικό του συστήματος και τη συχνότητα λειτουργίας. Για τη διενέργεια των πειραμάτων, η πειραματική διάταξη τοποθετήθηκε σε ανηχοϊκό θάλαμο, ο οποίος εξασφαλίζει την απομόνωσή της από τον περιβάλλοντα χώρο. Στις πειραματικές διαδικασίες που ακολουθήθηκαν, χρησιμοποιήθηκαν ομοιώματα, τα οποία στη φάση της υπερθερμίας υπέδειξαν τις περιοχές εστίασης της ενέργειας για την εκάστοτε συχνότητα ακτινοβολίας, ενώ στη φάση της μικροκυματικής ραδιομετρίας βοήθησαν στη μελέτη της θερμοκρασιακής διακριτικής ικανότητας του συστήματος. Η μέθοδος της μικροκυματικής ραδιομετρίας χρησιμοποιήθηκε για την παρακολούθηση των μεταβολών της θερμοκρασίας της ακτινοβολούμενης περιοχής κατά τη διάρκεια των συνεδριών της υπερθερμίας. Επίσης, κατά τη διάρκεια των πειραμάτων πραγματοποιήθηκαν μετρήσεις με στρώματα προσαρμογής από διηλεκτρικά υλικά, τα οποία τοποθετήθηκαν γύρω από το αντικείμενο ενδιαφέροντος και βοήθησαν στην πληρέστερη κατανόηση της επίδρασης της παρουσίας τους στις ιδιότητες εστίασης του συστήματος και στην επιβεβαίωση των αντίστοιχων θεωρητικών αποτελεσμάτων. / The application of hyperthermia process has been widely used in clinical research and efforts are being made for its implementation in clinical practice, as many researchers have used this method as an adjunct treatment procedure for cancer. During the past two decades, a great deal of research has been carried out, with the aim of developing effective techniques for hyperthermia treatment, primarily using RF, microwave and ultrasound energy. A similar effort is carried out in the Laboratory of Microwaves and Fiber Optics (MFOL), School of Electrical and Computer Engineering, National Technical University of Athens (NTUA), where a proposed hyperthermia system has been designed and constructed. A system for deep brain hyperthermia treatment, designed to also provide passive measurements of temperature and/or conductivity variations inside the human body, is presented in the present PhD thesis. The proposed system comprises both therapeutic and diagnostic modules, operating in a totally contactless way, based on the use of an ellipsoidal beamformer to achieve focusing on the areas under treatment and monitoring. The radiometry monitoring module, the Three Dimensional Passive Microwave Radiometry Imaging System (MiRaIS), has been studied, designed and constructed in the framework of a previous PhD thesis in the same laboratory of MFOL. In the present thesis, the proposed system is theoretically and experimentally studied. The operation principal is based on the use of an ellipsoidal conductive wall cavity for focusing the emitted radiation on the tissues that should accept treatment. The ellipsoidal cavity, which was constructed and used in the experimentation procedure, is newly developed and improves the system’s ergonomics retaining at the same time the focusing properties of the prototype system. In the framework of the present work, theoretical modeling and experimentation of the proposed system is carried out in order to examine and improve its focusing attributes. In the theoretical study, three setups are investigated for the improvement of the system’s focusing properties (e.g. penetration depth of the electromagnetic field, spatial sensitivity) using dielectric materials. The research is carried out with the use of a commercially available software tool, XFdtd (Remcom Inc.). The materials are placed inside the ellipsoidal or used as matching layers around the head model for the achievement of a stepped change of the refraction index on the air-human head model interface. The results revealed the possible advantages of using matching dielectric materials, as improvement on the focusing properties of the system is clearly observed, depending on the setup used, the position of the head model inside the system and the operating frequency. The experiments were performed inside an anechoic chamber providing maximum accuracy by avoiding all possible EMC/EMI issues. Along with the hyperthermia experiments, the implementation of the microwave radiometry process was also tested with the proposed system. Microwave radiometry could provide the temperature monitoring of the radiated area during the hyperthermia sessions. In the experimental procedures water phantoms were used, which during hyperthermia indicated the energy absorbing areas at the irradiation frequency, while during microwave radiometry revealed the system’s temperature sensitivity. Also, measurements were conducted using dielectric matching layers, placed around the medium of interest, in order to fully understand the effect of those materials on the system’s focusing properties as well as to confirm the respective theoretical results. Taking into consideration the present study and the advantage of the non invasive character of the proposed brain hyperthermia system, it is concluded that further research is required in order to explore its potentials at becoming a part of the standard treatment protocol of brain malignancy in the future.
147

Design And Analysis Of Integrated Optic Resonators For Biosensing Applications

Malathi, S 12 1900 (has links) (PDF)
In this thesis, we have designed and optimized strip waveguide based micro-ring and micro-ring and micro-racetrack resonators for biosensing applications. Silicon-On-Insulator (SOI) platform which offers several advantages over other materials such as Lithium Niobate, Silica on Silicon and Silicon nitride is considered here. High index contrast enables us to miniaturize the biosensor devices and monolithic integration of source and detectors on the same chip. We have considered the dispersive nature of the waveguide and proceeded towards optimization. Finite difference schemes and Finite Difference Time Domain (FDTD) methods are the primary tools used to model the biosensor. Various structures such as channel waveguides and beam structures are analyzed on the basis of their suitability for sensing applications. Strip and Rib waveguides are the two geometries considered in our studies. In an optical guiding structure, effective index of the propagating optical mode can be induced by two different phenomena: i. Homogeneous Sensing In this category, effective index of a propagating optical mode changes with uniformly distributed analytes extending over a distance well exceeding the evanescent field penetration depth. The sample serves as the waveguide cover. ii. Surface Sensing In the case of surface sensing, analytes bound to the surface of the waveguide. The effective index of an optical mode changes with the refractive index as well as the thickness of an adlayer. A thin layer of adsorbed or bound molecules transported from liquid or gaseous medium serving as waveguide cover is referred as an adlayer. Both homogeneous and surface sensing schemes are addresses in this work. By bulk sensing method, the characteristics of bioclad covering the device are studied. Optimization of the resonator structure involves the analysis of following parameters: • Gap between the ring and bus waveguides • Free spectral range • Extinction ratio • Quality factor We have achieved a maximum bulk sensitivity of 115 nm / RIU with ring waveguide width of 450 nm and bus width of 350 nm which is better than an earlier reported value of 70 nm/ RIU. We have proposed a novel detection scheme consisting of a micro-racetrack resonator formed over a cantilever structure. The devoice works on the principle of opto-mechanical coupling to detect conformational changes due to biomolecular adherence. BSA (Bovine Serum Albumin) and IgG ( Immuno Globulin G) are the two proteins considered in the work. Mechanical analysis of the beam for tensile and compressive stresses and corresponding spectral responses of the racetrack resonators are analyzed both by semi-analytical and method and numerical analyzes. We compared various aspects of rib and strip waveguide racetrack resonators. We have proved by numerical simulation, that the device is capable of distinguishing tensile and compressive stress. Two strip waveguides of dimensions : 450 nm X 220 nm and 400 nm X 180 nm, former supporting both Quasi-TE and Quasi-TM modes where as the second configuration allows only Quasi-TE mode alone. Sensitivity of the cantilever sensor is : 0.3196 x 10-3 nm/ µɛ at 1550 nm wavelength.
148

Radio wave imaging using Ultra-Wide Band Spectrum Antennas for Near-Field Applications. Design, Development, and Measurements of Ultra-Wideband Antenna for Microwave Near-Field Imaging Applications by applying Optimisation Algorithms

Danjuma, Isah M. January 2020 (has links)
The emergence of Ultra-wideband (UWB) technology application has yielded tremendous and vital impacts in the field of microwave wireless communications. These applications include military radar imaging, security screening, and tumour detection, especially for early detection of breast cancer. These indicators have stimulated and inspired many researchers to make the best use of this promising technology. UWB technology challenges such as antenna design, the problem of imaging reconstruction techniques, challenges of severe signal attenuation and dispersion in high loss material. Others are lengthy computational time demand and large computer memory requirements are prevalent constraints that need to be tackled especially in a large scale and complex computational electromagnetic analysis. In this regard, it is necessary to find out recently developed optimisation techniques that can provide solutions to these problems. In this thesis, designing, optimisation, development, measurement, and analysis of UWB antennas for near-field microwave imaging applications are considered. This technology emulates the same concept of surface penetrating radar operating in various forms of the UWB spectrum. The initial design of UWB monopole antennas, including T-slots, rectangular slots, and hexagonal slots on a circular radiating patch, was explicitly implemented for medical imaging applications to cover the UWB frequency ranging from 3.1 GHz to 10.6 GHz. Based on this concept, a new bow-tie and Vivaldi UWB antennas were designed for a through-the-wall imaging application. The new antennas were designed to cover a spectrum on a lower frequency ranging from 1 GHz - 4 GHz to ease the high wall losses that will be encountered when using a higher frequency range and to guarantee deeper penetration of the electromagnetic wave. Finally, both simulated and calculated results of the designed, optimised antennas indicate excellent agreement with improved performance in terms of return loss, gain, radiation pattern, and fidelity over the entire UWB frequency. These breakthroughs provided reduced computational time and computer memory requirement for useful, efficient, reliable, and compact sensors for imaging applications, including security and breast cancer detection, thereby saving more lives. / Tertiary Education Trust Fund (TET Fund) Supported by the Nigerian Defence Academy (NDA)
149

Reverberation Chamber Modeling Using Finite-Difference Time-Domain Method

Petit, Frédéric 12 1900 (has links)
Since the last few years, the unprecedented growth of communication systems involving the propagation of electromagnetic waves is particularly due to developments in mobile phone technology. The reverberation chamber is a reliable bench-test, enabling the study of the effects of electromagnetic waves on a specific electronic appliance. However, the operating of a reverberation chamber being rather complicated, development of numerical models are of utmost importance to determine the crucial parameters to be considered.This thesis consists in the modelling and the simulation of the operating principles of a reverberation chamber by means of the Finite-Difference Time-Domain method. After a brief study based on field and power measurements performed in a reverberation chamber, the second chapter deals with the different problems encountered during the modelling. The consideration of losses being a very important factor in the operating of the chamber, two methods of implementation of these losses are set out in this chapter. Chapter~3 consists in the analysis of the influence of the stirrer on the first eigenmodes of the chamber; the latter modes can undergo a frequency shift of several MHz. Chapter~4 shows a comparison of results issued from high frequency simulations and theoretical statistical results. The problem of an object placed in the chamber, resulting in a field disturbance is also tackled. Finally, in the fifth chapter, a comparison of statistical results for stirrers having different shapes is set out.

Page generated in 0.0885 seconds