Hållfasthetsberäkning av två T-stycken på fjärrvärmerör enligt SS-EN 13941 2003

Hans, Jörgensen, Lovasz, Ferencz January 2004 (has links)
No description available.
32

Handel med utsläppsrätter. Ett effektivt styrmedel på den svenska fjärrvärmemarknaden?

Karlsson, Ann-Charlotte, Rude, Jonas January 2007 (has links)
<p>In January 2005 the emission allowance system was introduced within the European Union and the first period ends at the end of 2007. The system was introduced in order to decrease the wastes of carbon dioxide and the system is a part of ratifying the Kyoto –protocol which first period runs between 2008-2012.</p><p>The idea of the system is to reduce the wastes of carbon dioxide where it costs less to do so and the expenses for the society therefore are as diminutive as possible. Different theories explain that companies can benefit from environment legislation and can depending on the company’s attitude gain competitive advantages improve its productivity and thereby increase its profitability.</p><p>With this in mind, the study aims at examining how the introduction of the emission trade system has influenced Swedish smaller companies in the distant heating industry, with focus on the factors attitude, innovation, competition and profitability. The study was implemented through interviews with five smaller distant heating companies.</p><p>The study shows that the companies mainly have a positive attitude towards the emission trading system but the general conclusion is that the system only influenced the companies marginally. Many companies have been assigned too many emission allowances which suppressed the incentive to trade allowances. We found that the investments that have been made in the last years can be connected to other factors than the introduction of the emission trading system.</p>
33

Handel med utsläppsrätter. Ett effektivt styrmedel på den svenska fjärrvärmemarknaden?

Karlsson, Ann-Charlotte, Rude, Jonas January 2007 (has links)
In January 2005 the emission allowance system was introduced within the European Union and the first period ends at the end of 2007. The system was introduced in order to decrease the wastes of carbon dioxide and the system is a part of ratifying the Kyoto –protocol which first period runs between 2008-2012. The idea of the system is to reduce the wastes of carbon dioxide where it costs less to do so and the expenses for the society therefore are as diminutive as possible. Different theories explain that companies can benefit from environment legislation and can depending on the company’s attitude gain competitive advantages improve its productivity and thereby increase its profitability. With this in mind, the study aims at examining how the introduction of the emission trade system has influenced Swedish smaller companies in the distant heating industry, with focus on the factors attitude, innovation, competition and profitability. The study was implemented through interviews with five smaller distant heating companies. The study shows that the companies mainly have a positive attitude towards the emission trading system but the general conclusion is that the system only influenced the companies marginally. Many companies have been assigned too many emission allowances which suppressed the incentive to trade allowances. We found that the investments that have been made in the last years can be connected to other factors than the introduction of the emission trading system.
34

Specifik värmeanvändning : Metod för framtagning av den specifika värmeanvändningen för fjärrvärmeanslutna flerbostadshus via Metrias fastighetsregister

Nilsson, Christophe, Beckne, Olle January 2013 (has links)
Fjärrvärme är idag den vanligaste uppvärmningsformen för flerbostadshus i Sverige, med en täckningsgrad uppemot 90 %. Länge har fjärrvärme varit det billigaste uppvärmningsalternativet för fastigheter i tätorter, men har på senare tid fått konkurrens av bland annat billiga och effektiva värmepumpar. För att behålla sina fjärrvärmekunder ställs det krav på leverantören att jobba mer kundorienterat genom att bland annat analysera kunders värmeanvändning samt värmebehov. Ett sätt att göra detta är att få fram kundens specifika värmeanvändning uttryck i kWh/m2. Rapporten presenterar en metod för att få fram den specifika värmeanvändningen för flerbostadshus bland Öresundskrafts fjärrvärmekunder i Helsingborg och Ängelholm. Metoden utgår ifrån Metrias fastighetsregister för sammanställning av ytorna för Öresundskrafts fjärrvärmekunder. Därefter matchas ytorna för respektive fastighet med uppgifter om leverarad fjärvärmemängd från Öresundskrafts kundregister. Totalt är det 1 326 fastigheter med flerbostadshus som undersökts. Resultatet uppvisar en spridning mellan 2,8 kWh/m2 till strax över 2600 kWh/m2 med en median på 109 kWh/m2. Ungefär 85 % av fastigheterna har en specifik värmeanvändning mellan 64 kWh/m2 och 170 kWh/m2, vilket anses vara den normala spridningen. Värden på den uppvärmda ytan som räknats fram utifrån Metrias fastighetsregister har jämförts med värden som fåtts direkt från fastighetsbolag. Resultatet från jämförelsen är blandat och uppvisar i flertalet fall olika värden för samma fastighet. Dock går det inte urskilja om Metras eller fastighetsbolagets värde som är mest korrekt. Vidare har den uppvärmda ytan och mängden levererad fjärrvärme för ett antal fastigheter med extrem hög och låg specifik värmeanvändning jämförts med dess energideklarationer. I flertalet av dessa fall har orsaken till extremvärdena gått att lösa vid kontakt med ägare till byggnaderna, med hjälp av flygfoton över området kring fastigheten eller genom att urskilja byggnadens användningsområde.   Metoden är enkel, billig och kan implementeras omgående i företaget. Resultaten ger en tydlig överblick över den specifika värmeanvändningen för fjärrvärmeanslutna flerbostadshus och metoden används med fördel som första gallring för att se vilka fastigheter som behöver åtgärder. / District heating is currently the most common form of heating for apartment buildings in Sweden, with a ratio up to 90%. It has for a long time been the cheapest heating option for real estate in urban areas but has recently been challenged by cheap and efficient heat pumps. Suppliers are required to work more customer oriented to keep their heating customers, for instance by analyzing the customers heating usage. One way to do that is to get the customer's specific heat consumption expressed in kWh/m2. This report presents a method for obtaining the specific heat consumption of apartment buildings among Öresundskraft’s district heating customers in Helsingborg and Ängelholm. The method assumes Metria’s land registry to compile surfaces for Öresundskraft’s heating customers. The area for each property is matched with the delivered heat from Öresundskraft’s customer database. In total there are 1,326 properties with apartment buildings. The results show a variation between 2.8 kWh/m2 to over 2,600 kWh/m2 with a median of 109 kWh/m2. Approximately 85% of the properties have a specific heat use between 64 kWh/m2 and 170 kWh/m2, which is considered the normal distribution. The values ​​of the heated areas as calculated from Metria’s land registry are compared with values ​​obtained directly from the real-estate company. The result of the comparison is mixed and has in most cases different values ​​for the same property. However, it can’t be distinguished if Metra or the real-estate company’s value is the most accurate. The heated surface and the quantity delivered heating for a number of properties with extreme high and low specific heat consumption are compared with its energy return. In most of these cases the cause of the extreme values ​​has been resolved through contact with the owners of the buildings, with the help of aerial photographs or by identifying the building's usage. The method is inexpensive, easy to use and can be used instantly to companies. The results provides a clear overview of the specific heat consumption for district heating connected apartment buildings and the method is ideal as a first screening to see which properties needs improvements.
35

Säsongslagring av spillvärme : Ersättning av Halmstad fjärrvärmenäts spetslastanläggning

Berg, Nichlas, Kårhammer, Per January 2013 (has links)
I Sverige används mycket energi för uppvärmning av bostäder och lokaler. För att uppfylla det ständigt ökande behovet av värme, byggs exempelvis nya värmeproducerande anläggningar som komplement i fjärrvärmesystem. Samtidigt finns det outnyttjad energi i industrin som i sin produktion får värme som oönskad biprodukt. Denna rapport undersöker möjligheten att utnyttja denna biprodukt från industrin för att tillföra energi till ett befintligt fjärrvärmenät och lagra i ett säsongsvärmelager. När värmebehovet ökar under den kalla delen av året, skall säsongsvärmelagret bidra med värme. Idén är att lagret skall ersätta delar av de värmeproducerande anläggningarna som utnyttjas i Halmstads fjärrvärmesystem. Målet är att all fossil bränsleanvändning skall kunna tas bort. Rapporten undersöker även ekonomiska lönsamheten samt miljövinsten i att ersätta del av biobränsleanvändningen. I Halmstad finns ett stålverk, Höganäs Halmstadverken, som kan bidra med överskottsenergi i form av värme. Rapporten genomför beräkningar på industrins potential att leverera prima värme till fjärrvärmenätet. Med hjälp av beräkningar och simuleringar i Microsoft Excel tas ett system med lämplig lagringsmetod samt spillvärme från lokal industri fram. Detta system skall optimeras med hänsyn till ekonomiska och miljömässiga förutsättningar. Resultatet visar att Halmstads förutsättningar är goda för att integrera ett groplager samt att det finns potential att leverera spillvärme från Höganäs Halmstadverken. Storlekarna på vattenburna säsongsvärmelager optimeras till 200 000 m3 för ersättning av endast fossila bränslen respektive 550 000 m3 för ersättning av fossila och biobränslen. Spillvärmeeffekten från Höganäs Halmstadverken beräknas till 15 MW. De ekonomiska kalkylerna resulterar i en årlig vinst på upp till 8 miljoner kronor med en payoff-tid på 8 år. Den totala miljövinsten i minskade växthusgasutsläpp blir 4 800 ton koldioxidekvivalenter per år. / In Sweden, a great deal of energy is used for residential and commercial heating. To fulfill the ever increasingly need for heat, new heating plants is built to complement the district heating system. At the same time there is unused energy in industry, which produces heat as an unwanted byproduct. This report evaluates the possibility to use this byproduct to supply energy to a district heating system and store it in seasonal heat storage. When the heat demand increases during the cold season of the year, the seasonal heat storage contributes with heat energy. The idea is to replace parts of the heating plants in Halmstad with heat storage and waste heat. The aim is to exclude usage of all fossil fuels. This report will also evaluate the economical prerequisites and environmental benefits in replacing biofuels. A steelworks company, Höganäs Halmstadverken, is situated in Halmstad. This industry could contribute with surplus heat, which is calculated in this report. With help of calculations and simulations in Microsoft Excel, a system with adequate heat storage method and surplus heat from local industry is formed. This system is optimized concerning economic and environmental matters. The results reveal that Halmstad's conditions are favorable to integrate pit heat storage and there is potential to deliver waste heat from Höganäs Halmstadverken steelworks. Sizes of seasonal heat storage is optimized to 200 000 m3 for replacing fossil fuels respectively 550 000 m3 for replacing fossil fuels and biofuels. Waste heat effect is calculated to 15 MW. The economical calculations results in an annual profit up to 8 million SEK with a payoff equal to 8 years. The environmental benefits consisting of reduced greenhouse gases are calculated to 4 800 tons carbon dioxide equivalents annually.
36

Energiförluster i eternitkulvert och flödeskartläggning av Kramfors fjärrvärmenät / Energy losses in asbestos cement pipes and flow mapping of Kramfors district heating network

Hussein, Gomil January 2013 (has links)
Kramfors heating network was built in the 1960s. Culverts that were used at the time were composed of a pipe of steel, asbestos cement (eternite) and polyurethane foam (PUR foam) blown with chlorofluorocarbons gas (CFC gas) as insulation. The expansion of district heating began during the 1970s and 1980s and even more in 1990s. One problem that may arise during expansion of a district heating network is the risk of overloading the main pipes of the heating network if they were designed for lower flows. The aim of this work is to calculate energy losses from eternite culvert over a twelve months period to then compare losses, both financially and from an energy perspective, with today culvert as a reference. Even a flow mapping on the network will be presented for the month of December 2012 as a basis for future growth of subscriber stations. Eternit culvert energy losses was more than twice as much as the losses with modern culvert for the reason that the heat conductivity in the eternit culvert is about 3 times higher compared with modern culverts. If Neova has to supply the entire investment, the analysis shows that if the price of the fuel and the energy losses is constant throughout the payoff time it would take 104 years for the investment to pay off. / Kramfors fjärrvärmenät började byggas under 1960-talet. Kulvertar som då utnyttjades var uppbyggd av ett medierör av stål, asbestcement (eternit) och polyuretan-skum (PUR-skum) uppblåst med klorfluorkarboner-gas (CFC-gas) som isoleringsmaterial. Under 1970- och 1980-talen började fjärrvärmen i orten byggas ut och vid 1990-talet expanderades fjärrvärmen starkt. Ett problem som kan uppstå vid utbyggnation är att distributionsledningar i fjärrvärmenätet riskerar att blir överbelastade ifall de är dimensionerade för lägre flöden. Syftet med detta arbete är att beräkna förluster på eternitkulverten under en tolvmånadsperiod för att sedan jämföra försluter, både ekonomiskt och energimässigt, med modern kulvert som referens. Även en flödeskartläggning i nätet kommer att presenteras för december månad 2012 som underlag för framtida tillökning av abonnentcentraler. Eternitkulvertens energiförluster blev mer än dubbelt så mycket som förlusterna hos modern kulvert av den anledningen att värmeledningsförmågan i eternitkulverten är ca 3 gånger så hög jämfört med modern kulvert. Om Neova står själv för hela investeringen så indikerar den gjorda analysen att det skulle ta 104 år för investeringen att betala av sig. Detta gäller dock om bränslepriset och energiförlusterna är konstanta under hela återbetalningstiden.
37

Hållfasthetsberäkning av två T-stycken på fjärrvärmerör enligt SS-EN 13941 2003

Hans, Jörgensen, Lovasz, Ferencz January 2004 (has links)
No description available.
38

Fjärrvärmesystem

Holmström, Susanne January 2008 (has links)
This is a report written for an examination project C-level, on the subject of energy. The examination project is a product of the FVB Sweden AB (district heating bureau). It started with a meeting with Stefan Jonsson FVB Sweden AB, were he explained the content of the project, and from this a presentation of the problem was made. The problem that needed to be solved was how they could control the valves in the system to provide heating to everyone in the system. The valves are often oversized so the pump in the heating plant would have to be enormous to be able to provide enough flow to be sufficient, if everyone in the system had there valves fully opened.   I came up with two solutions to the problem, one was a wireless network that could keep track of the valves and the other solution was an extra sensor that was placed on the radiator. The purpose for that was to open the valve if the temperature dropped more than one degree inside. With the help of a program called IDA it was calculated that, if the temperature drop five degrees, they would have sixteen hours at the heating power plant to open the flow before the sensor open the valves.   After careful consideration I came up with the conclusion that the wireless network must be the best solution. Mostly because you can monitor all the clients in the system from the heating power plant and that will make it easier to discover faults and temperature differences. Wireless networks is already a well tested solution in form of wireless controlled electricity meters so it shouldn’t be to much of a problem connecting these sensors to it either.
39

Utvärdering av ett större bergvärmesystem i en flerbostadsfastighet som har konverterats från fjärrvärme / Evaluation of a geothermal heating system in an apartment building converted from district heating

Jonsson, Björn January 2011 (has links)
This master thesis is an in-depth study of an existing heating system at a household cooperative in Uppsala that has been converted from district heating to a bedrock heat pump system. The study focuses on an economical system optimisation of the building’s complete heating system. The aim was to determine how well a heat pump system in large buildings actually work, find out possible ways to optimize the existing system and point out important system parameters for new heat pump installations in larger buildings. The project points out a possible energy cost reduction of 45 % without investment and further cost reductions with equipment investments. A reduction by 30 % is possible by improvements in the regulation system and 15 % is possible by maintaining the brine system. Many other energy efficiency improvements are possible by investment in new equipment.  An important conclusion of the project is that there is a huge need of an energy coordinator for the energy operation of buildings. The different people involved need to cooperate in order to maximize the optimization of the heating systems.
40

Utredning av värmepump med fjärrvärmespets

Hedlund, Sandra January 2012 (has links)
Det här är ett examensarbete som handlar om en fastighet som står på Norra Kungsgatan 37-43 som har både en värmepump och fjärrvärme för uppvärmning. Värmepumpen används i första hand och fjärrvärmen används som spets när värmepumpen inte räcker till. Detta är en ganska ovanlig kombination. Syftet med arbetet är att ta reda på om detta är en bra lösning och om lösningen är lönsam. För att få fram hur stort fastighetens energibehov är så görs beräkningar utifrån fjärrvärmedata från tidigare år samt en gammal värmepump som är utbytt sedan 2011. Byggnadens energibehov uppskattas vara ungefär 895 MWh/år och värmepumpen beräknas täcka 54 % av värmebehovet. Utifrån detta jämförs sedan kostnaden för uppvärmning av fastigheten med endast fjärrvärme med kostnaden för uppvärmning med både värmepumpen och fjärrvärme. Genom att använda värmepumpen så sparas drygt 140 000 kr per år. Det innebär att värmepumpen är lönsam rent ekonomiskt. Däremot kan användningen av högkvalitativ energi för uppvärmning diskuteras. Värme som är energi med lägre kvalitet borde i första hand användas för uppvärmning. Det för att inte slösa på våra dyrbara energiresurser och på så sätt få en hållbar utveckling. / This is an essay about a property at Norra Kungsgatan 37-43 who is heated with both a heat pump and district heating. The heat pump is used primarily and district heating is used as a tip when the heat from the heat pump is not enough. This is a pretty rare combination. The purpose of this essay is to find out if this is a good solution and if the solution is economically viable. To determine the heat demand of the property, calculations based on district heating data and heat pump data from previously years has been used. The heat demand of the building is estimated to be approximately 895 MWh/year and the heat pump is estimated to cover 54% of the heat demand. Based on this, the cost for heating the building with district heating is compared with the cost of heating the building with the heat pump and district heating. By using the heat pump, more than 140 000 kronor per year can be saved. This means that the heat pump is economically viable. However, the use of high-quality energy for heating is discussed. Heat is energy with lower quality and should be used primarily for heating. We can not waste our precious energy resources if we want to achieve sustainable development.