Spelling suggestions: "subject:"low calculation"" "subject:"flow calculation""
1 |
Shortening time-series power flow simulations for cost-benefit analysis of LV network operation with PV feed-inLópez, Claudio David January 2015 (has links)
Time-series power flow simulations are consecutive power flow calculations on each time step of a set of load and generation profiles that represent the time horizon under which a network needs to be analyzed. These simulations are one of the fundamental tools to carry out cost-benefit analyses of grid planing and operation strategies in the presence of distributed energy resources, unfortunately, their execution time is quite substantial. In the specific case of cost-benefit analyses the execution time of time-series power flow simulations can easily become excessive, as typical time horizons are in the order of a year and different scenarios need to be compared, which results in time-series simulations that require a rather large number of individual power flow calculations. It is often the case that only a set of aggregated simulation outputs is required for assessing grid operation costs, examples of which are total network losses, power exchange through MV/LV substation transformers, and total power provision from PV generators. Exploring alternatives to running time-series power flow simulations with complete input data that can produce approximations of the required results with a level of accuracy that is suitable for cost-benefit analyses but that require less time to compute can thus be beneficial. This thesis explores and compares different methods for shortening time-series power flow simulations based on reducing the amount of input data and thus the required number of individual power flow calculations, and focuses its attention on two of them: one consists in reducing the time resolution of the input profiles through downsampling while the other consists in finding similar time steps in the input profiles through vector quantization and simulating them only once. The results show that considerable execution time reductions and sufficiently accurate results can be obtained with both methods, but vector quantization requires much less data to produce the same level of accuracy as downsampling. Vector quantization delivers a far superior trade-off between data reduction, time savings, and accuracy when the simulations consider voltage control or when more than one simulation with the same input data is required, as in such cases the data reduction process can be carried out only once. One disadvantage of this method is that it does not reproduce peak values in the result profiles with accuracy, which is due to the way downsampling disregards certain time steps in the input profiles and to the averaging effect vector quantization has on the them. This disadvantage makes the simulations shortened through these methods less precise, for example, for detecting voltage violations.
|
2 |
Quantifizierung des Luftvolumenstromes in frei gelüfteten Rinderställen mit Hilfe der Kompartimentalisierungsmethode zur Bestimmung umweltrelevanter Emissionsmassenströme / Air flow calculation in natural ventilated dairy stables with the method of compartmentalisation to determine emission mass flows of important environmental gasesBrehme, Gunnar 23 November 2000 (has links)
No description available.
|
3 |
VALIDATION AND CONFORMITYTEST OF CGMES MODELS OFENTSO-E TEST NETWORKSZhao, Yiqi January 2016 (has links)
För att uppnå optimal resursdelning och öka hållbar energiförsörjning, stiger behovet av gränsöverskridande kraftöverföring ständigt. Därför frekventa utbyta information med detaljerade galler uppgifter krävs. För att standardisera sådant utbyte och därigenom främja gemensam kraftsystemstudier i Europa, Common Grid Model Exchange Standard (CGMES) grundar sig på IEC CIM (Common Information Models) utfärdats av ENTSO-E (European Network of Transmission Operators for Electricity) i 2013. En CGMES bedömning av överensstämmelse processen också inrättats att uppmuntra och undersöka antagandet av CGMES med relevanta kraftsystemtillämpningar. Huvudsyftet med denna avhandling är att validera att Network Manager produkten av ABB har genomfört CGMES ordentligt. Effektflödesberäkningar utförs baserat på ENTSO-Es provnäten och erhållna lösningarna jämförs med standard resultat samt resultaten från Power Factory (ett kraftsystem analysverktyg från DIgSILENT som redan har passerat bedömningen av överensstämmelse med framgång). Jämförelse resultaten analyseras alltså för att identifiera orsakerna till eventuella avvikelser från standardeffektflödeslösningar och ge förslag på framtida utveckling av Network Manager. / To achieve optimal resource sharing and enhance the sustainability of energy supply, the need for cross-border power transmission is continuously growing. Therefore, frequent information exchange with detailed grid data is required. To standardize such exchange and thus to facilitate common power system studies in Europe, the Common Grid Model Exchange Standard (CGMES) based on IEC CIM (Common Information Models) was issued by ENTSO-E (European Network of Transmission Operators for Electricity) in 2013. A CGMES conformity assessment process was also set up to encourage and examine the adoption of CGMES with relevant power system applications. The main purpose of this thesis is to validate that the Network Manager product of ABB has implemented CGMES properly. Power flow calculations are performed based on ENTSO-E’s test networks and the solutions obtained are compared with the standard results as well as the results from Power Factory (a power system analysis tool from DIgSILENT that has already passed the conformity assessment successfully). The comparison results are analyzed thus to identify causes of any variation from the standard power flow solutions and to give suggestions for future development of Network Manager.
|
4 |
Beräkning av pumpkapacitet samt konstruktion av pumpfundament / Calculation of pump capacity and construction of a pump foundationBeijer, Anton, Lindholm, Magnus January 2013 (has links)
Ett undersöknings- och utvecklingsarbete för att lösa ett problem med att dränkbara pumpar i ett vattenavrinningssystem gick sönder med perioder på två år i genomsnitt, utfördes i samarbete med Cementa AB i Skövde. Orsak till pumpars haveri söktes och fanns vara bristande rutiner och kunskap om det underhåll pumparna krävde. För att lösa detta problem utvecklades riktlinjer för nyinköp av torruppställda pumpar för att möjliggöra kontinuerligt underhåll. Då möjligheter för placering av torruppställd pump saknades utvecklades ett pumpfundament för placering av torruppställd pump. Krav för utvecklingsarbetet togs fram i samarbete med Cementas underhållsavdelning och teoretisk dimensionering av dränkbara länspumpars dåvarande volymflödeskapacitet utfördes. Krav utvärderades och viktades med hjälp av parvis jämförelse. Dimensionering och kontroll av hållfasthet för utvecklat pumpfundamentet utfördes med hjälp av Finita Element Analyser i programvaran Pro/Engineer Creo 1.0 Mechanica. Kontroll av hållfasthet i infästning av pumpfundamentet samt svetsfogar utfördes analytiskt. Arbetet resulterade i en rekommendation till Cementa AB i Skövde att ta in offerter på nya torruppställda pumpar med hjälp av utvecklade riktlinjer och att tillverka det pumpfundament som tagits fram inom ramen för examensarbetet, för att placera nya pumpar på. Att noggrant följa de underhållsinstruktioner som pumpar har och att underlätta för personal att utföra detta underhåll ansågs kunna bidra till att pumpar skulle få en längre och mer ekonomisk livslängd. / A development project to solve problems with why submersible pumps in a run-off system broke down with periods of two years, on average, was performed in collaboration with Cementa AB in Skövde. Reason for the pumps breakdowns was searched and found to be inadequate procedures and missing knowledge of the maintenance required on the pumps. To solve this problem, guidelines for the purchase of new dry pit pumps were developed to allow for continuous maintenance. As the possibilities of placing a dry well pump did not exist at Cementa, a pump foundation was developed. Requirements for the development work were produced in cooperation with Cementas maintenance department and theoretical dimensioning of the submersible bilge pumps volume flow capacity was performed. Requirements were evaluated and weighted using Pairwise comparison. The design and control of the strength of the developed pump foundation was performed using finite element analysis in the software Pro/Engineer Creo 1.0 Mechanica. Controls of the strength of the attachment of the pump foundation and welds were performed analytically. The work resulted in a recommendation to Cementa AB in Skövde to bring in quotes on the new dry-pit pumps using the developed guidelines and to manufacture the pump foundation developed within the framework of the thesis. Cementa was also recommended to carefully follow the maintenance instructions for pumps and make it easier for staff to perform this maintenance. This was recommended to ensure that new pumps would have a longer and more economical lifetime.
|
5 |
Reservmatningsmöjligheter vid transformatorhaveri / Backup power supply in case of transformer breakdownJarl, Markus, Bengtsson, Fredrik January 2015 (has links)
Kungälv Energi äger och ansvarar idag över Kungälv Kommuns elnät. Med en ökande befolkningsmängd ställs allt högre krav på elnätet och framför allt leveranssäkerheten. Med kalla vintrar och stort energibehov ger detta upphov till en svårare situation gällande leveranssäkerhet. I nuläget har Kungälv Energi två mottagarstationer, en 130/10kV-station espektive 130/20kV-station. 30/10kV-stationen börjar närma sig en gräns där effektbehovet närmar sig den maximala istributionskapaciteten. Därför fastställs en plan för att kunna klara av effektbehovet vid averi på en av två 130/10kV-transformatorer i mottagarstationen M1. Resultatet av rapporten visar att tillräcklig kapacitet finns i närliggande fördelningsstationer för att klara av reservdrift under hög belastning utan att några övriga komponenter skadas. Rapporten behandlar främst effektflöden för att kontrollera att dessa ej överskrider transformatorernas, ledningarnas och kablarnas märkeffekt. I flertalet fall har även faktorer för nödbelastning räknats med vilket resulterar i att samtliga linjer hos Kungälv Energi klarar av den ökade belastningen. Upptäckta flaskhalsar i nätet har uppmärksammats och delgetts samt förslag till förändringar för att förhindra framtida problem. / Kungälv Energi owns and is responsible of Kungälv municipality's electricity grid. With an increasing population and increasing demands on the grid and especially security of supply. With cold winters and large energy gives rise to a more difficult situation regarding security of supply. Currently, Kungälv Energi two receiving stations, a 130 / 10kV station and 130 / 20kV station. 130 / 10kV station is approaching a point where power demand is approaching the maximum distribution capacity. Therefore sets out a plan to cope with the power demand at the failure of one of two 130 / 10kV transformers of the receiving station M1. The results of the report shows that sufficient capacity is available in nearby distribution stations to cope with the emergency operation under high loads without any other components damaged. The report deals primarily with power flows to check that they do not exceed transformers, lines and cables rated power. In the majority of cases have also factors for distress load been counted with, which gives the result that all lines of Kungälv Energi can handle the increased load. Detected bottlenecks in the network have been highlighted, communicated and proposed changes to Kungälv Energi to prevent future problems.
|
6 |
Urychlení výpočtů v životním pojištění / Acceleration of calculations in life insuranceKuzminskaya, Kseniya January 2018 (has links)
One of the major issue for life insurance companies is proper and consistent valuation of liabilities. This thesis introduces the standard estimation methods used in practice and discussed the alternative methods, which might help to speed up these calculations. It studies two possible methods of acceleration of calcu- lations in life insurance: analytic function and cluster analysis. The outcome of these work is comparison of discussed methods applied on generated life insur- ance portfolio. All methods were applied on two possible insurance products. Comparison of the results is based on the calculation precision and time needed to process the liabilities of the insurance company's portfolio. 1
|
7 |
A Performance Evaluation of Low Pressure Carbon Dioxide Discharge TestLee, Sung-Mo 30 April 2004 (has links)
For gaseous fire extinguishing systems, the maximum percent of agent in pipe, i.e., pipe volume vs. agent liquid volume should be determined for proper system design and performance by confirming the maximum length of pipe run in which their flow calculation methods can predict the discharge pressures and agent concentration. It is the purpose of this paper to determine the ability and limitations of the NFPA 12 flow calculation methodology to identify the maximum percent of agent in pipe by conducting full scale low-pressure CO2 system discharge tests. A total of twenty low-pressure CO2 system discharge tests were conducted under different conditions. If all the measured pressures at the three node points of pipe runs and the measured CO2 concentrations in the test enclosures did not deviate from the predicted values of computerized flow calculations by more than ¡¾10 percent, the tests were judged to be acceptable. In the test results, the low-pressure CO2 system with a pipe run exceeding 492 ft (150 m) was not likely to achieve the concentration required for fire extinguishment within the determined discharge time although the pipe network was installed in compliance with the calculations based on the pressure drop equation in NFPA 12.
|
8 |
Vliv disperzních zdrojů na DS 22 kV při vřazení transformovny TR 110/22 KV / Effect of distributed generation on medium voltage 22 kV distribution system operation with a new 110/22 kV feederKonopová, Tamara January 2018 (has links)
This thesis deals with the issue of power flow analysis in a medium voltage (22kV) distribution network with a focus on the influence of distributed energy generation recources. At first the issue of operation of distributed energy resources and their reverse effects on the distribution system is presented in the thesis. Furtherly there are described their operational conditions from the legislation point of view. The part dealing with calculation compares two network configurations in terms of power quality and how the power quality is impacted by distributed energy resources. The attention is given to voltage conditions, short-circuit power, power conditions, losses and flicker. The first configuration corresponds to the real situation in the network, the other one is describing the changes after the new 110/22 kV substation implementation to the power supply area and the overal change of network configuration. The network model and run simulation is done using the E-Vlivy program.
|
9 |
Study of a generation capacity expansion on an islandGuilmineau, Justine Valérie Magali January 2020 (has links)
The study carried out in this master thesis is part of a larger project led by Energynautics GmbH focusing on renewable energy development in the Caribbean. One of the Caribbean states, consisting of multiple islands, has set a target of 30 % of renewable energy in the power sector by 2030. The first objective of the thesis is to develop optimal generation capacity expansion plans for two different islands of this country, utilizing solar PV generation, which is the only available renewable energy resource. To achieve this objective, three main tasks are identified. The first is the development of an optimal generation capacity expansion plan for the next three years using the optimization tool HOMER Energy. At the beginning only diesel generation is present on the islands. For each study case year, the installed capacity of PV and BESS is optimized and enabling technologies such as curtailment (controllability of PV) and grid-forming inverters are deployed. The second task focuses on the development of a new dispatch strategy, improving on the black box dispatch algorithms built into HOMER. The dispatch strategy minimises the cost of electricity generation and is based on a rolling 48 hours forecasts of the load and PV. It is implemented in MATLAB and linked to HOMER via the built-in MATLAB interface. As HOMER is focused on generation expansion and dispatch and inherently neglects the grid, a grid study is required to assess the stability of the network. This study is the last task of the thesis and is limited to determined steady-state voltage and the asset loading on one of the studied islands through load flow simulations in DIgSILENT PowerFactory. It is shown that there are no major issues even at high PV shares, however, grid performance can be improved if the PV unit is equipped with reactive power capability to control the voltage. A study on the impact of the Q(U)- control and the PQ-capability of the PV and BESS inverters is performed. / Studien som genomförts i detta examensarbete är en del av ett större projekt vilket leds av Energynautics GmbH med fokus på utveckling av förnybar energi i Karibien. En av de Karibiska staterna, bestående av flera öar, har ett mål på 30 % förnybar energi i elkraftssektorn innan 2030. Första syftet med examensarbetet är att utveckla optimala utbyggnadsplaner för produktionskapaciteten för två olika öar i detta land, med användning av solcellsproduktion, vilket är den enda tillgängliga förnybara energikällan. Den första uppgiften är utvecklingen av en optimal utbyggnadsplan för produktionskapaciteten för de kommande tre åren med optimeringsverktyget HOMER Energy. Från början fanns det bara dieselgeneratorer på öarna. För varje studerat år optimeras den installerade kapaciteten av PV och BESS samt aktivering av möjliggörande teknologier som begränsning av PV-produktion och grid-forming växelriktare. Den andra uppgiften fokuserar på utvecklingen av en ny driftsstrategi, förbättring av den basala driftsalgoritm som är inbyggd i HOMER. Driftsstrategin minimerar kostnaden av elproduktionen och är baserad på en 48 timmars prognos av laster och PV. Den är implementerad i MATLAB och kopplad till HOMER via det inbyggda MATLABgränssnittet. Eftersom HOMER fokuserar på produktionsutbyggnad och drift och i praktiken försummar elnätet, krävs en studie av elnätet för att utvärdera stabiliteten av elnätet. Studien av denna sista uppgift i examensarbetet är begränsad till att bestämma spänningen vid jämnviktsläge och den utvärderade lasten på en av de studerade öarna genom belastningsfördelningsberäkning i DIgSILENT PowerFactory. Det visade sig att det inte fanns några stora problem även med stora andelar PV, men elnätets prestanda kan förbättras om PV-omriktarna är utrustade med reaktiv effektstyrning som kontrollerar spänningen. En studie avinverkan från Q(U)-styrning och PQ-kapacitet av PV- och BESS-växelriktare har utförts.
|
10 |
Návrh přírodě blízkých opatření na vodním toku Bobrava / Proposal for the nature friendly measures on the river BobravaMláděnka, Jakub January 2019 (has links)
The aim of the diploma thesis is to describe and evaluate in detail the current state of the Bobrava river in the interest section – river kilometer 1,832-5,743. Part of the work is to assess the capacity of the river flow and the objects connected with it and find the class of an actual safety at village Zelesice. The calculation of the flow rate is performed by using the 1D mathematical model HEC-RAS for selected N-year flows. On the basis of the results of the flow rate, it is made the idea of natural freindly flood protection before the value of the 20-year flow. The result is two variants of river basin adjustment, when each one is leading to make Zelesice safer place and to improve the current state of the river Bobrava.
|
Page generated in 0.1283 seconds