• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 159
  • Tagged with
  • 159
  • 159
  • 107
  • 105
  • 97
  • 67
  • 58
  • 55
  • 53
  • 38
  • 38
  • 36
  • 33
  • 32
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Solução do fluxo de potência ótimo reativo com variáveis discretas utilizando um método de pontos interiores e exteriores com estratégia de correção de inércia / Solution of the reactive optimal power flow problem with discret variables using an interior and exterior point method with a strategy of inertia correction

Tófoli, Marielena Fonseca [UNESP] 02 June 2017 (has links)
Submitted by MARIELENA FONSECA TÓFOLI null (tofoli.mf@gmail.com) on 2017-07-23T23:57:51Z No. of bitstreams: 1 Dissertacao_MarielenaTofoli.pdf: 7712392 bytes, checksum: 832f7cd96b1d7fc53bf7cd7dc4fa2bd4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-07-26T13:58:42Z (GMT) No. of bitstreams: 1 tofoli_mf_me_bauru.pdf: 7712392 bytes, checksum: 832f7cd96b1d7fc53bf7cd7dc4fa2bd4 (MD5) / Made available in DSpace on 2017-07-26T13:58:42Z (GMT). No. of bitstreams: 1 tofoli_mf_me_bauru.pdf: 7712392 bytes, checksum: 832f7cd96b1d7fc53bf7cd7dc4fa2bd4 (MD5) Previous issue date: 2017-06-02 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O problema de Fluxo de Potência Ótimo Reativo (FPOR) tem como objetivo otimizar um critério associado a potência reativa do sistema elétrico, levando em conta os limites físicos e técnicos-operacionais do mesmo. O problema de FPOR é formulado como um problema de programação não-linear com variáveis contínuas e discretas. Em muitos trabalhos da literatura, as variáveis discretas do problema de FPOR são consideradas como contínuas e a solução obtida é ajustada para o valor discreto mais próximo do conjunto de valores discretos pré-estabelecidos. Tal abordagem descaracteriza a representação real do problema associado ao sistema elétrico, além de resultar em soluções não ótimas ou até mesmo em soluções infactíveis. Este trabalho propõe uma abordagem de solução para tratar as variáveis discretas do problema de FPOR. Utiliza-se uma função penalidade senoidal que penaliza as variáveis discretas quando estas assumem valores que não pertencem ao conjunto discreto pré-estabelecido. A metodologia geral de solução proposta, utiliza métodos de pontos interiores e exteriores em conjunto com o método de penalidade para o tratamento das variáveis discretas. Mostra-se que a função penalidade senoidal introduz dificuldades para a convergência do método de pontos interiores e exteriores para pontos de mínimos. Para a correção deste problema, propõe-se uma estratégia de correção de inércia de modo a garantir a obtenção de mínimos locais do problema penalizado. O método de solução proposto foi implementado em Matlab e aplicado aos sistemas elétricos IEEE 14, 30, 57 e 118 barras. Os resultados obtidos evidenciam a eficiência da abordagem proposta. / The Reactive Optimal Power Flow (FPOR) has the objective of optimizing a criterion associated with the reactive power of the electric system, taking into account the physical and technical-operational limits of the same. The FPOR problem is formulated as a nonlinear programming problem with continuous and discrete variables. In many works of the literature, the discrete variables of the FPOR problem are considered to be continuous and the solution obtained is adjusted to the nearest discrete value of the set of preset discrete values. Such an approach de-characterizes the actual representation of the problem associated with the electrical system, as well as resulting in non-optimal solutions or even infeasible solutions. This work proposes a solution approach to treat the discrete variables of the FPOR problem. A sinusoidal penalty function is used that penalizes the discrete variables when they assume values that do not belong to the pre-established discrete set. The proposed general solution methodology uses interior and exterior point methods in conjunction with the penalty method for the treatment of discrete variables. It is shown that the sinusoidal penalty function introduces difficulties for the convergence of the method to minimum points. In order to correct this problem, a strategy of correction of inertia is proposed in order to guarantee the obtaining of local minimums of the penalized problem. The proposed solution method was implemented in Matlab and applied to IEEE 14, 30, 57 and 118 buses. The results obtained evidenced the efficiency of the proposed approach.
52

Estratégias de controle de fluxo de potência associadas à utilização de banco de baterias em sistemas fotovoltaicos conectados a rede elétrica.

DIAS, Túlio Albuquerque. 20 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-20T14:37:35Z No. of bitstreams: 1 TÚLIO ALBUQUERQUE DIAS – DISSERTAÇÃO (PPGEE) 2016.pdf: 5822647 bytes, checksum: 7cd3ed5c6dd5eedcd93037a70c98ddd7 (MD5) / Made available in DSpace on 2018-04-20T14:37:35Z (GMT). No. of bitstreams: 1 TÚLIO ALBUQUERQUE DIAS – DISSERTAÇÃO (PPGEE) 2016.pdf: 5822647 bytes, checksum: 7cd3ed5c6dd5eedcd93037a70c98ddd7 (MD5) Previous issue date: 2016-10-18 / Capes / Este trabalho trata da aplicação da geração fotovoltaica residencial associada à utilização de banco de baterias com a finalidade de reduzir à elevação e variação da potência injetada na rede. Dessa forma o sistema de armazenamento é utilizado para absorver a energia excedente imposta pela geração ao longo do dia fornecendo ou absorvendo potência constante a rede elétrica. Diante desta abordagem, este trabalho tem por objetivo descrever e analisar estratégias de controle em sistemas FV associadas ao controle de carga e descarga de um banco de baterias chumbo-ácido associadas em série, para reduzir a alta potência injetada na rede, devido ao fato que o pico de geração, muitas vezes não coincide com o horário de pico de consumo. Foram apresentadas topologias convencionais para este tipo de sistema e partir da escolha de uma topologia genérica, foi obtido à modelagem do sistema FV/Bateria conectado a rede elétrica para obter as funções de transferência e respectivas malhas de controle da planta. Na sequência foi feito uma avaliação das estratégias de controle aplicadas, gerando resultados por simulação e experimentais que validam as estratégias analisadas. Para avaliar a redução da potência injetada na rede com a inserção do sistema de armazenamento, foi descrito um modelo simplificado da rede de BT. Os resultados obtidos via simulação comprovaram que foi possível regular adequadamente o fluxo de potência dos painéis para as baterias e a rede elétrica, como também reduzir a variação e elevação da potência na rede, gerada pela mudança dos níveis de irradiação. Como consequência desta ação foi evidenciada também à redução da elevação da tensão no Ponto de Acoplamento comum (PAC). / This work deals with the application of residential photovoltaic generation associated with the use of battery banks with the purpose of reducing the elevation and variation of the injected power in the network. In this way the storage system is used to absorb the surplus energy imposed by the generation during the day supplying or absorbing constant power to the electrical network. In this approach, this work aims to describe and analyze control strategies in PV systems associated with the control of load and discharge of a bank of lead-acid batteries associated in series, to reduce the high power injected in the network, due to the fact that The generation peak often does not coincide with peak consumption times. It was presented the conventional topologies for this type of system and from the choice of a generic topology, was obtained to the modeling of the FV / Battery system connected to the electrical network to obtain the transfer functions and respective control meshes of the plant. An evaluation of the applied control strategies was carried out, generating simulation and experimental results that validate the analyzed strategies. To evaluate the reduction of the injected power in the network with the insertion of the storage system, a simplified model of the LV network was described. The results obtained through simulation showed that it was possible to adequately regulate the power flow of the panels to the batteries and to the electrical network, as well as to reduce the variation and increase of the power in the network, generated by the change of the irradiation levels. As a consequence of this action was also evidenced to the reduction of the voltage increase at the Common Coupling Point (PAC).
53

Uma nova abordagem para resolução do problema de fluxo de potência ótimo utilizando os métodos de Newton e pontos interiores / not available

Luiz Cláudio Teixeira Nunes 03 December 2001 (has links)
Este projeto de pesquisa teve o objetivo de desenvolver uma nova abordagem para a resolução do Fluxo de Potência Ótimo. Para isso, foram obtidos dados teóricos, a partir de um levantamento bibliográfico, que explicitaram os conceitos de otimização aplicados ao sistema estático de energia elétrica. A pesquisa fundamentou-se metodologicamente nos métodos: Newton-Langragiano, Penalidade e Função Barreira Logarítmica de Newton Projetada. Os sistemas de equações resultantes das condições de estacionaridade da função Lagrangiana foram resolvidos pelo método de Newton. Na implementação computacional foram utilizadas técnicas de esparsidade. Foram realizadas estudos para validação e a verificação da abordagem proposta nos sistemas de 3, 14, 30 e 118 barras. / This research project had the objective of developing a new approach for the resolution of the Optimum Power Flow. For this purpose, theoretical data were obtained through a bibliographical survey, which explained the optimization concepts applied to the electrical energy static system. The research was based on the methods: Newton-Lagrangian, Penalty and Projected Newton Barrier Function. The systems of equations resulting from the Lagrangian function stationarity conditions were resolved through the Newton\'s method. In the computational implementation, sparsity techniques had been used. Studies had been carried out for the proposed approach validation and verification in the systems of 3, 14, 30 and 118 buses.
54

Estudo de planejamento de reativos em sistemas elétricos de potência / Study of reactive planning in electrical power systems

Thales Sousa 27 February 2003 (has links)
Este trabalho propõe o desenvolvimento de uma nova abordagem para a resolução do problema de planejamento de reativos em sistemas elétricos de potência. Um levantamento bibliográfico para explicitar as diferentes pesquisas realizadas nesta área foi feito. Este trabalho utiliza os multiplicadores de Lagrange obtidos da solução de um fluxo de potência ótimo, via método dos Pontos Interiores, para determinar as barras onde serão alocados reativos. A partir da determinação destas barras, um problema de programação linear para quantificar a potência reativa a ser alocada, é resolvido. Foram realizados estudos para validação e verificação da abordagem proposta nos sistemas WARD & HALE de 6 barras, sistema de 8 barras, sistema IEEE 30 e 118 barras. / The present dissertation proposes the development of a novel approach to the solution of reactive planning problem in electrical power systems. A bibliographical survey to show the different researches developed in this area was done. This study uses langrange multipliers obtained from the optimal power flow solution, through interior point method, to determine the buses where reactive power will be allocated. Starting from the determination of these buses, a linear programming problem is solved to quantify the reactive power to be allocated. Studies were carried ou for the proposed approach validation and verification in the systems Ward & Hale of 6 buses, system of 8 buses, systems IEEE of 30 and 118 buses.
55

Fluxo de Potência Ótimo globalmente convergente utilizando métodos de pontos interiores com estratégias de região de confiança

Sousa, Andréa Araújo 09 1900 (has links)
O problema de Fluxo de Potência Ótimo (FPO) vem sendo estudado desde a década de 1960 e vários métodos de resolução são encontrados na literatura. Em particular, os métodos de Pontos-Interiores (PI) vêm tendo um grande destaque devido a sua robustez e eficiência, alcançando convergência com reduzido número de iteraçoes mesmo em problemas com um grande número de variáveis. Apesar do seu bom desempenho computacional no que se refere a número de iterações e tempo de processamento, os métodos de PI não possuem convergência global, que consiste em encontrar uma solução independente da escolha do ponto inicial. Um dos objetivos desta pesquisa é o desenvolvimento de um algoritmo de FPO globalmente convergente, ou seja, capaz de encontrar uma solução sempre que uma existir. Para atingir esse objetivo, o algoritmo proposto associa métodos de Região de Confiança com os eficientes métodos de PI. Algoritmos globalmente convergentes são invariavelmente computacionalmente intensivos, de forma que três abordagens distintas para a resolução dos subproblemas de região de confiança foram estudadas. Quanto à formulação do problema de FPO, foram desenvolvidos modelos que consideram dispositivos FACTS, como o UPFC (Unified Power Flow Controller), e restrições de estabilidade de tensão. Algumas opções de função objetivo, como minimização de perdas, minimização de corte de carga e maximização de carregamento, foram testadas e o desempenho do algoritmo proposto foi avaliado comparando-o ao desempenho de algoritmos de PI já conhecidos.O problema de Fluxo de Potência Ótimo (FPO) vem sendo estudado desde a década de 1960 e vários métodos de resolução são encontrados na literatura. Em particular, os métodos de Pontos-Interiores (PI) vêm tendo um grande destaque devido a sua robustez e eficiência, alcançando convergência com reduzido número de iteraçoes mesmo em problemas com um grande número de variáveis. Apesar do seu bom desempenho computacional no que se refere a número de iterações e tempo de processamento, os métodos de PI não possuem convergência global, que consiste em encontrar uma solução independente da escolha do ponto inicial. Um dos objetivos desta pesquisa é o desenvolvimento de um algoritmo de FPO globalmente convergente, ou seja, capaz de encontrar uma solução sempre que uma existir. Para atingir esse objetivo, o algoritmo proposto associa métodos de Região de Confiança com os eficientes métodos de PI. Algoritmos globalmente convergentes são invariavelmente computacionalmente intensivos, de forma que três abordagens distintas para a resolução dos subproblemas de região de confiança foram estudadas. Quanto à formulação do problema de FPO, foram desenvolvidos modelos que consideram dispositivos FACTS, como o UPFC (Unified Power Flow Controller), e restrições de estabilidade de tensão. Algumas opções de função objetivo, como minimização de perdas, minimização de corte de carga e maximização de carregamento, foram testadas e o desempenho do algoritmo proposto foi avaliado comparando-o ao desempenho de algoritmos de PI já conhecidos.O problema de Fluxo de Potência Ótimo (FPO) vem sendo estudado desde a década de 1960 e vários métodos de resolução são encontrados na literatura. Em particular, os métodos de Pontos-Interiores (PI) vêm tendo um grande destaque devido a sua robustez e eficiência, alcançando convergência com reduzido número de iteraçoes mesmo em problemas com um grande número de variáveis. Apesar do seu bom desempenho computacional no que se refere a número de iterações e tempo de processamento, os métodos de PI não possuem convergência global, que consiste em encontrar uma solução independente da escolha do ponto inicial. Um dos objetivos desta pesquisa é o desenvolvimento de um algoritmo de FPO globalmente convergente, ou seja, capaz de encontrar uma solução sempre que uma existir. Para atingir esse objetivo, o algoritmo proposto associa métodos de Região de Confiança com os eficientes métodos de PI. Algoritmos globalmente convergentes são invariavelmente computacionalmente intensivos, de forma que três abordagens distintas para a resolução dos subproblemas de região de confiança foram estudadas. Quanto à formulação do problema de FPO, foram desenvolvidos modelos que consideram dispositivos FACTS, como o UPFC (Unified Power Flow Controller), e restrições de estabilidade de tensão. Algumas opções de função objetivo, como minimização de perdas, minimização de corte de carga e maximização de carregamento, foram testadas e o desempenho do algoritmo proposto foi avaliado comparando-o ao desempenho de algoritmos de PI já conhecidos.
56

Coordenadas polares versus coordenadas retangulares no cálculo do ponto de máximo carregamento em sistemas elétricos de potência / Polar versus rectangular coordinates for computing the maximum loading point in electrical power systems

Guedes, Magda Rocha 10 March 2007 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-02-09T12:58:32Z No. of bitstreams: 1 magdarochaguedes.pdf: 585612 bytes, checksum: 0367ab5f0166e5be66517299ab882bb7 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Isabela, favor corrigir o nome da instituição que está: Editor: Universidade Federal de Minas Gerais (UFMG) on 2017-02-10T10:38:01Z (GMT) / Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-02-10T12:10:39Z No. of bitstreams: 1 magdarochaguedes.pdf: 585612 bytes, checksum: 0367ab5f0166e5be66517299ab882bb7 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-02-10T13:37:39Z (GMT) No. of bitstreams: 1 magdarochaguedes.pdf: 585612 bytes, checksum: 0367ab5f0166e5be66517299ab882bb7 (MD5) / Made available in DSpace on 2017-02-10T13:37:39Z (GMT). No. of bitstreams: 1 magdarochaguedes.pdf: 585612 bytes, checksum: 0367ab5f0166e5be66517299ab882bb7 (MD5) Previous issue date: 2007-03-10 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O aumento contínuo da demanda aliado as restrições econômicas e ambientais para a expansão das capacidades de geração e transmissão tem propiciado a operação dos sistemas elétricos de potência cada vez mais próxima de seus limites operativos. Conseqüentemente, a estabilidade de tensão é hoje um dos temas mais importantes tanto para as concessionárias de energia elétrica, quanto para os pesquisadores do meio acadêmico. Face a esta situação, torna-se cada vez mais premente, a necessidade de desenvolver novas metodologias e avaliar as existentes, de modo a possibilitar uma análise acurada da estabilidade de tensão. Neste contexto, este trabalho aborda o cálculo do ponto de máximo carregamento através da utilização dos métodos do fluxo de potência continuado e do ponto de colapso. Além disto, e como idéia principal, tem como objetivo avaliar o desempenho destas metodologias, quando as equações básicas que caracterizam a rede elétrica são expressas tanto em coordenadas polares, quanto em coordenadas retangulares. Os resultados apresentados enfocam o número de iterações e a trajetória de convergência dos processos iterativos referentes ao fluxo de potência continuado e ao método do ponto de colapso. Análises de autovalores, autovetores e vetores tangentes também são apresentados. Sistemas testes do IEEE e um modelo equivalente da região Sul-Sudeste brasileira são utilizados na simulação dos resultados. / The continuous loading growth allied to the lack of investments in generation and transmission areas has led to a electrical power system operated closer to its operating limits. Therefore, voltage stability is one of the most relevant themes for electrical energy companies, as well as for academic researchers. In view of this scenario, mathematical approaches applied to performing an accurate voltage stability analysis should be developed and/or evaluated. Thus, the present work deals with the computation of the maximum loading point through continuation power flow and point of collapse methods. In addition, the primary objective is to evaluate the performance of these methodologies when the electrical network equations are expressed in both polar and rectangular voltage coordinates. The results presented focus on the number of iterations and convergence trajectory associated with the iterative process of the continuation power flow and point of collapse methods. Eigenvalues, eigenvectors and tangent vectors are also presented. IEEE test systems and a South-Southeastern Brazilian network are used in the simulations.
57

Análise de defeitos em coordenadas de fase utilizando modelagem a quatro condutores e fluxo de potência continuado / Fault analysis by phase coordinates using four-wire modeling and continuation power flow

Riani, Leandro Matos 08 August 2017 (has links)
Submitted by isabela.moljf@hotmail.com (isabela.moljf@hotmail.com) on 2017-02-24T15:41:49Z No. of bitstreams: 1 leandromatosriani.pdf: 1003631 bytes, checksum: f252cd6ec851c2cb8adc2e0581c01c02 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-03-06T19:27:12Z (GMT) No. of bitstreams: 1 leandromatosriani.pdf: 1003631 bytes, checksum: f252cd6ec851c2cb8adc2e0581c01c02 (MD5) / Made available in DSpace on 2017-03-06T19:27:12Z (GMT). No. of bitstreams: 1 leandromatosriani.pdf: 1003631 bytes, checksum: f252cd6ec851c2cb8adc2e0581c01c02 (MD5) Previous issue date: 2017-08-08 / Na maioria das metodologias de fluxo de potência e análise de faltas, os efeitos dos cabos neutros e dos aterramentos do sistema são negligenciados ou incorporados nas fases, através da redução de Kron. Desta forma, as correntes e tensões de neutros e aterramentos permanecem desconhecidas, limitando a análise. Neste trabalho é apresentada uma formulação para o cálculo de defeitos em coordenadas de fase através da modelagem completa do sistema trifásico a quatro condutores, com representação explícita do condutor de neutro e das impedâncias de aterramento do sistema. Os desequilíbrios da rede e da carga, impedâncias mútuas, gerações dispersas, transformadores com suas mais variadas conexões e formas de aterramento também são considerados na modelagem. Adicionalmente, as cargas podem ser representadas durante o defeito como potência constante, corrente constante, impedância constante, ou ainda qualquer combinação entre estes modelos. A metodologia de solução é baseada na técnica do fluxo de potência continuado, onde as impedâncias que representam o defeito são os parâmetros de continuação. A formulação é de uso geral podendo ser utilizada na solução de qualquer tipo de defeito em sistemas de transmissão, subtransmissão, distribuição e industriais. Foram aplicadas diversas faltas, simples e simultâneas, em sistemas didáticos, sistemas teste do IEEE, e em sistemas elétricos reais, onde se constatou a eficiência da metodologia proposta para análise de defeitos, destacando-se os estudos de afundamento de tensão. / The effects of neutral wires and system grounding in most power flow and fault analysis methodologies are neglected or merged into phases using Kron’s reduction method. Thus, the neutral wire and ground currents and voltages remain unknown, restricting the analysis. This work presents a new formulation for fault analysis in the phase domain using three-phase, four-wire modeling, in which the neutral wires and grounding impedances explicitly represented. Unbalanced systems and loads, mutual impedances, dispersed generation, transformers with the most varied forms of grounding and connections are also represented in modeling. In additional, the loads can be represented as constant power, constant current, constant impedance or any combination among these models during the fault analysis. The solution methodology is based on the continuation power flow technique, where the fault impedances are continuation parameters. The proposed algorithm is of general usage and can be used to solve any kind of fault in transmission, subtransmissão, distribution and industrial systems. Several faults, simple and simultaneous, were conduct in academicals systems, IEEE distribution test feeders and real power systems. Simulation results show the efficiency of the proposed methodology for fault analysis, highlighting voltage sag studies.
58

Metodologia intervalar para tratamento de incertezas em problemas de fluxo de potência / Interval method for handling uncertainties in power flow problems

Pereira, Luiz Eduardo de Souza 05 April 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-24T12:34:54Z No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 2003245 bytes, checksum: 5a64db7cc6de6ef524f087c6d4cdb47e (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-24T16:55:28Z (GMT) No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 2003245 bytes, checksum: 5a64db7cc6de6ef524f087c6d4cdb47e (MD5) / Made available in DSpace on 2017-04-24T16:55:28Z (GMT). No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 2003245 bytes, checksum: 5a64db7cc6de6ef524f087c6d4cdb47e (MD5) Previous issue date: 2011-04-05 / A análise do fluxo de potência determinístico é restrita a um único instante de tempo específico. Contudo, as demandas de potência ativa e reativa, dentre outros, variam constantemente e afetam o perfil das tensões nodais e as distribuições dos fluxos de potência nos ramos do sistema elétrico. Desta forma, a utilização do modelo determinístico seria inviável face às inúmeras simulações necessárias no sentido de representar todas as possíveis combinações das variações envolvidas no problema. Por outro lado, com a utilização da matemática intervalar é possível representar intervalos de variação da demanda ativa e reativa e obter, através de um fluxo de potência intervalar, o perfil das tensões nodais, as distribuições de fluxo de potência nos ramos e as perdas também na forma intervalar. Por conseguinte, é possível realizar uma análise detalhada e completa do comportamento da rede frente às variações em estudo. Da mesma forma que no fluxo de potência determinístico, a metodologia intervalar apresenta diferentes desempenhos dependendo da forma como as equações básicas que definem o problema do fluxo de potência são expressas. Portanto, a proposta do trabalho é inicialmente modelar e implementar as metodologias de fluxo de potência intervalar nas versões polar, retangular e injeção de correntes. Posteriormente, o trabalho apresenta um estudo comparativo entre as várias versões aplicada ao problema das incertezas no fluxo de potência em redes de energia elétrica. / The analysis of the deterministic power flow is restricted to a single time instant. However, the active and reactive load powers, among others, vary constantly and affect the voltage profiles and line flows throughout electric power systems. Therefore, the deterministic model is not feasible due to a number of simulations required to represent all possible combinations of the variations involved in the problem. On the other hand, it is possible to represent the variations of active and reactive load powers by interval mathematics. As a result, voltage profiles, line flows and losses can be calculated, in an interval manner, by using an interval power flow. Therefore, a detailed and comprehensive analysis of the system behavior can be efficiently performed. Both the interval and deterministic power flow methods have different performance depending on how the basic power flow equations are expressed. Therefore, the purpose is to firstly model and implement load flow methodologies in polar, rectangular and current injections versions. Next, this dissertation presents a comparative study between the versions applied to power flow problem with uncertainties.
59

Ferramenta para maximização de carga na fase fluente de recomposição de sistemas elétricos

Viana, Eduardo Martins 13 August 2008 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-24T13:25:57Z No. of bitstreams: 1 eduardomartinsviana.pdf: 1013683 bytes, checksum: 5d87e6aef68844b7f67e1941a0337702 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-04-24T16:55:49Z (GMT) No. of bitstreams: 1 eduardomartinsviana.pdf: 1013683 bytes, checksum: 5d87e6aef68844b7f67e1941a0337702 (MD5) / Made available in DSpace on 2017-04-24T16:55:49Z (GMT). No. of bitstreams: 1 eduardomartinsviana.pdf: 1013683 bytes, checksum: 5d87e6aef68844b7f67e1941a0337702 (MD5) Previous issue date: 2008-08-13 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho propõe uma metodologia para auxiliar os estudos relacionados à recomposição fluente de sistemas elétricos de potência. Nesta fase inicial de recomposição, o sistema de potência encontra-se estruturado em longos corredores de transmissão e a definição de uma configuração de reatores constitui uma das estratégias adotadas para a eliminação de sobretensões. A ferramenta proposta, baseada em um modelo de otimização, visa o estabelecimento de procedimentos de rede que conduza a uma configuração mínima de reatores conectados ao sistema e a máxima tomada de carga durante esta fase de recomposição. Os diversos cenários de recomposição fluente, correspondentes à energização de novos trechos de linhas de transmissão, são representados através de subproblemas. A técnica de decomposição de Benders associada à metodologia primal-dual de pontos interiores é utilizada para solução do problema de otimização não-linear proposto. São realizados estudos de caso em ramos de recomposição fluente do Sistema Elétrico Brasileiro interligado para verificar a eficácia da metodologia. Os resultados obtidos são comparados com outros métodos propostos na literatura. / This work proposes a methodology to help the studies related to electric power systems fluent restoration. At this early restoration stage, power system is structured in long transmission corridors and the reactors set definition is one of the adopted strategies for overvoltages disposal. The proposed tool, based on an optimization model, aims the network procedures establishment leading to a minimum reactors configuration connected to the system and maximum load pick-up during this restoration phase. The various fluent restoration scenarios, corresponding to new transmission lines sections inrush, are represented by sub problems. Benders decomposition technique associated to primal-dual interior points methodology is used to solve the proposed nonlinear optimization problem. Case studies are conducted in fluent restoration branches of Brazilian Electric interconnected System to verify the methodology effectiveness. The results are compared with other proposed methods in the literature.
60

Metodologias generalizadas de solução do fluxo de potência intervalar considerando dados incertos / Generalized methodologies of interval power flow solution considering data uncertainties

Pereira, Luiz Eduardo de Souza 12 June 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-01-07T17:13:46Z No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 1798748 bytes, checksum: 8dd5bfcce6449767d768c651966a061d (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-01-25T16:52:02Z (GMT) No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 1798748 bytes, checksum: 8dd5bfcce6449767d768c651966a061d (MD5) / Made available in DSpace on 2016-01-25T16:52:02Z (GMT). No. of bitstreams: 1 luizeduardodesouzapereira.pdf: 1798748 bytes, checksum: 8dd5bfcce6449767d768c651966a061d (MD5) Previous issue date: 2015-06-12 / A análise do fluxo de potência determinístico é restrita a um único instante de tempo específico. Contudo, as demandas de potência ativa e reativa, dentre outros, variam constantemente e afetam o perfil das tensões nodais e as distribuições dos fluxos de potência nos ramos do sistema elétrico. Desta forma, a utilização do modelo determinístico seria inviável, face às inúmeras simulações necessárias no sentido de representar todas as possíveis combinações das variações envolvidas no problema. Com a utilização da matemática intervalar é possível representar intervalos de variação das demandas ativa e reativa, dos parâmetros de linha e obter, através de um fluxo de potência intervalar, o perfil das tensões nodais, as distribuições de fluxo de potência nos ramos e as perdas também na forma intervalar. Por conseguinte, é possível realizar uma análise detalhada e completa do comportamento da rede frente às variações em estudo. A proposta do trabalho é modelar e implementar as metodologias de fluxo de potência intervalar, nas versões polar e injeção de correntes, incorporando o controle de geração de reativo em barras PV e o limite de tensão em barras PQ nos vários pontos de operação, incluindo o ponto de máximo carregamento. A simulação de Monte Carlo é utilizada como parâmetro para a aferição dos resultados. / The analysis of the deterministic power flow is restricted to a single time instant. However, the active and reactive load powers, among others, vary constantly and affect the voltage profiles and line flows throughout electric power systems. Therefore, the deterministic model is not feasible due to a number of simulations required to represent all possible combinations of the variations involved in the problem. The interval mathematics can represent ranges of active and reactive power demand. As a result, through an interval power flow, the voltage profile at all nodes, the distribution of power flow in the branches and the losses in the interval form can also be calculated. It is therefore possible to perform a detailed analysis of the network taking into account the uncertainties under study. The purpose of this study is to model and implement the polar and the current injection interval power flow formulations incorporating the reactive power generation control on PV buses and voltage limit control on PQ buses. Various operating points are considered, including maximum loading point. The Monte Carlo simulation is used to validate the proposed methodologies.

Page generated in 0.0725 seconds