• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • 7
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 81
  • 27
  • 26
  • 23
  • 18
  • 16
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Uplift resistance of foundations

Ray Chaudhuri, Kiriti Prosad January 1977 (has links)
No description available.
2

Fondation et Fondement. Mise en place et Statut du Dispositif Fondationnel dans le champ métaphysique et postmétaphysique

de Salle, Corentin C.P.C. 10 February 2005 (has links)
L’objet de cette thèse consiste à prouver que les deux notions métaphysiques que sont la fondation et le fondement sont à la fois distinctes et indissociables pour constituer un système philosophique. Fonder philosophiquement est une opération nécessitant l’articulation de deux ordres hétérogènes mais interconnectés : l’ordo essendi et l’ordo cognoscendi.
3

Bâtir pour l'éternité : le cardinal Pierre des Prés (1280-1361) et la collégiale Saint-Martin de Montpezat-de-Quercy / To build for the eternity : cardinal Pierre des Prés (1280-1361) and the collegial church of Montpezat-de-Quercy

Moureau, Emmanuel 14 May 2018 (has links)
Durant la papauté d'Avignon,si la plupart des cardinaux sont inhumés soit dans la cité pontificale, soit dans leur pays d'origine, certains d'entre eux choisissent au contraire de fonder dans leur lieu d'origine non seulement une communauté religieuse mais également des bâtiments pour accueillir leur tombeau. Ils imitent en cela les papes successifs, notamment Clément V et Clément VI. En parallèle, se développe au XIVe siècle, sous l’impulsion de Jean XXII, la création de nouvelles collégiales séculières dans le Midi de la France. Pierre des Prés (1280-1361), quercynois, est un proche de Jean XXII. Juriste, il gagne la confiance du pape qui le créé cardinal en 1321, puis l’investit de la charge de vice-chancelier de l’Église en 1325. La première partie de ce travail est consacrée à une biographie de ce personnage et montre également son désir d’élever socialement les membres de sa famille. Le cardinal des Prés est aussi, tout comme d’autres cardinaux parmi ses contemporains, le fondateur d’une communauté religieuse, chargée de veiller sur sa dépouille. S’il a choisi des chanoines séculiers, d’autres ont privilégié les ordres Mendiants. C’est ce choix qui est examiné et étudié dans la seconde partie. Pour abriter ces religieux, Pierre des Prés a fait édifier une église dans son village natal, Montpezat-de-Quercy. Classée au titre des Monuments Historiques dès 1840, cet édifice s’avérait peu connu. Notre étude replace la collégiale Saint-Martin dans son contexte de construction, entre 1337 et 1343, mais présente également les matériaux utilisés, les techniques employées, l’organisation du chantier et les hommes qui ont oeuvré sur le projet. Enfin, la dernière partie aborde la question de la mémoire du cardinal, construite grâce à son tombeau et aux nombreux objets offerts par lui à son chapitre collégial. Grâce à ces derniers, le souvenir de Pierre des Prés s’est transmis de siècle en siècle, donnant ainsi raison aux vers de Pétrarque : la renommée vainc la mort. / During the papacy of Avignon, so most cardinals are buried either in the pontifical city, or in their country of origin, some of them choose contrary to founding in their place of origin not only one religious community but also of the buildings to accommodate their tomb. They imitate in that the successive popes, in particular Clement V and Clement VI. In parallel, develops at the 14th century, under the impulse of John XXII, the creation of secular collegial news in the South of France.Pierre des Prés (1280-1361), quercynois, is a close relation of John XXII. Lawyer, it gains the confidence of the pope who created it cardinal in 1321, then invests it in 1325 load of vice-chancellor of the Church. The first part of this work is devoted to a biography of this character and also shows his desire to socially raise the members of its family.The cardinal des Prés is also, just like of other cardinals among his contemporaries, the founder of a religious community, charged to take care on his skin. If it chose secular canons, others privileged the orders Beggars. These is the choice which is examined and studied in the second part. To shelter these monks, Pierre des Prés made build a church in his native village, Montpezat-of-Quercy. Classified with the title as of Historic buildings by 1840, this building proved little known. Our study replaces collegial church Saint Martin in her context of construction, between 1337 and 1343, but also presents the materials used, the techniques employed, the job management and the men who have work on the project. Lastly, the last part tackles the question of the memory of the cardinal, built thanks to his tomb and with the many objects offered by him to its collegial chapter. Thanks to the latter, the memory of Pierre des Prés was transmitted of century in century, thus agreeing with the worms of Pétrarque: the fame overcomes death.
4

Corrosion des cornières de fondation, existence et conséquences

Beaulieu, Louis-Vincent January 2008 (has links)
Aujourd'hui, les pylônes à treillis en acier sont les structures les plus utilisées dans les réseaux de transport de l'énergie électrique en Amérique du Nord. Ces structures présentent un intérêt au niveau de leur coût et de leur facilité de l'assemblage lors de la construction. Néanmoins, l'acier demeure un matériau corrodable. Dès leur mise en service, les lignes de transport d'énergie vieillissent et se corrodent. Certaines des structures existantes ont été construites il y a plus de 70 ans et la plupart de ces structures servent toujours, malgré leur vie utile estimée a 50 ans. Afin d'établir un programme de réparation et de maintenance efficient pour ces structures âgées, il est essentiel, dans un premier temps, d'évaluer leur état. L'évaluation de leur état est une tâche très fastidieuse à cause du manque d'information précise et de la nature complexe de la détérioration possible. De plus, certains éléments structuraux sont enfouis. Il est donc à propos de se questionner sur le comportement des fondations des pylônes à treillis dans le futur. Il faut tout d'abord identifier le problème et prouver que certaines fondations des pylônes en service peuvent être affectées par la corrosion. Il est pertinent de déterminer comment repérer les pylônes qui sont plus sujet au développement de la corrosion au niveau de leur fondation. Il faut ensuite évaluer à quel point la corrosion affecte la capacité structurale de la fondation selon son niveau de développement, donc de déterminer la capacité résiduelle d'une cornière corrodée. C'est dans cette optique que la Chaire de recherche CRSNG/HQTÉ a proposé un projet de maîtrise visant à approfondir les connaissances sur l'état des membrures de pylônes enfouies des pylônes à treillis en acier et d'évaluer leur intégrité structurale. Le présent projet de maîtrise tente d'éclaircir ces points d'investigation par ses objectifs qui sont de déterminer les paramètres influençant la corrosion des fondations de pylônes existants et d'être en mesure d'évaluer les possibilités de corrosion dans le futur et de déterminer la capacité résiduelle des cornières corrodées en compression.
5

Poséidon en terre d'Athènes : un dieu entre séisme et fondation

Darthou, Sonia 24 June 2000 (has links) (PDF)
Cette recherche, qui propose une réflexion sur la construction de l'identité mythique d'Athènes et son lien au territoire, choisit de revaloriser la place de Poséidon, trop souvent marginalisé dans la cité d'Athéna. La thèse est scindée en deux parties : la première suit Poséidon au cœur de la terre, la deuxième le consacre fondateur à l'issue du partage qui s'opère avec Athéna. J'ai tout d'abord choisi d'analyser les compétences de Poséidon sur la terre : tenir/soutenir le sol, assurer les assises, enraciner et soutenir les fondations. La cité d'Athènes, qui se raconte autochthone car elle n'a pas été fondée sur le mode de la " colonisation ", renouvelle dans ses discours mythiques en permanence ses fondations avec la terre qui l'a générée. Elle va ainsi accorder au dieu Poséidon une place centrale en terre d'Athènes à l'issue d'un mythe de partage qui met en rivalité deux prétendants au titre de Poliade. Si Athéna gagne l'eris en recevant le titre " politique", Poséidon n'est pas exclu pour autant. Certes, Athéna protège et représente la cité, défend les murs d'Athènes et s'affiche sur les monnaies, mais c'est Poséidon qui pose l'ultime maillon de fondation de la polis. Gardien des origines, garant de la stabilité, ce dieu à l'assise sûre que les citoyens appellent Celui qui tient la terre, siège en réalité avec tous les honneurs sur la cité autochthone. Grâce à Poséidon, Athènes a réussi le pari de son " autofondation " car ce sont tous les Athéniens que le dieu enracine sur leur propre terre.
6

La fondation philanthropique et le droit / Philanthropic foundation and its legal framework

Pol, Eve 10 December 2016 (has links)
Les fondations philanthropiques sont la source d’un intarissable questionnement, au sein duquel les règles de droit sont largement sollicitées. Que l’on songe à la création, au fonctionnement ou à la disparition des fondations… Un examen approfondi du droit positif permet de montrer que les règles de droit classiques sont souvent inadaptées au dynamisme que requiert la pratique philanthropique. À partir des résultats de cette analyse, la recherche d’une optimisation entre les règles juridiques et les véhicules d’actions d’intérêt général peut être envisagée. Cette optimisation pourrait être obtenue de plusieurs manières complémentaires, par l’amélioration de l’accessibilité des fondations à des financements multiples, par l’observation des organismes à but non lucratif concurrents de la fondation, par l’édification d’une éthique de la fondation, et par la rénovation de sa fiscalité. La fondation philanthropique apparaît ainsi, au fil de l’étude, comme un véritable laboratoire de recherche appliquée en droit fiscal, en droit administratif, et en droit comparé / French Philanthropic foundations are the source of endless questions, in which the laws governing them are sought. Think of the creation, operation or disappearance of foundations... This thorough review of positive foundation law shows that the classical laws are often inadequate for the dynamism required by philanthropic practice. This work investigates the optimization between legal rules and vehicles of public interest, which could be obtained in several complementary ways : by improving the accessibility of foundations to multiple financing, by the stricter observation of non-profit organizations competing with the foundation, by building an ethics of foundations, or by the renovation of its taxation system. The philanthropic foundation appears throughout the study as a true research laboratory for tax law, administrative law, and comparative law
7

Serviceability and safety in the design of rigid inclusions and combined pile-raft foundations / Calcul des déplacements et sécurité dans le dimensionnement des fondations mixtes et inclusions rigides

Bohn, Cécilia 30 September 2015 (has links)
Les inclusions rigides sont un concept récent développé dans le prolongement des fondations mixtes, avec un matelas de transfert de charges entre les colonnes et la structure. Des méthodes de calculs et des concepts de sécurité existent pour ces systèmes combinés, notamment en France où le module pressiométrique mesuré et les recommandations ASIRI (IREX 2012) pour les inclusions rigides sont utilisés. Le dimensionnement classique des pieux basé sur une simple vérification de la portance des colonnes isolées ne peut pas être appliqué à ces systèmes combinés. Les tassements peuvent être plus importants du fait de la part significative de charge reprise par le sol. Le présent travail est une contribution au développement des méthodes de calcul et de dimensionnement en déplacement (préconisé par l'Eurocode 7, EN 1997-1 2004) pour les systèmes combinés sous charge verticale, en particulier au niveau international où des mesures in situ de module de sol ne sont généralement pas disponibles. Les éventuelles particularités de ces systèmes, notamment la sensibilité de colonnes non renforcées de petit diamètre, devaient également être examinées. La méthode de transfert de charge (“load transfer method”, LTM) est identifiée comme un outil d'ingénieur particulièrement adapté au calcul des systèmes combinés présentant une géométrie relativement simple. L'interaction sol-colonne en frottement et en pointe est définie par des courbes de transfert de charge (ou courbes “t-z” et “q-z”). Les méthodes en milieu continu comme la méthode des éléments finis sont à réserver en général aux cas complexes. Le comportement non-linéaire des semelles est examiné sur la base de mesures obtenues dans la littérature. Cette étude aboutit à la proposition d'une courbe charge-tassement hyperbolique pour les semelles. Cette courbe de mobilisation est définie de sorte qu'il y ait concordance avec la méthode linéaire habituelle pour un tiers de la charge ultime de la semelle. Le comportement de pieux isolés est étudié avec de nombreux essais de chargement instrumentés et non-instrumentés pour différents types de pieux et de sol. Une alternative aux courbes de transfert de charge selon Frank et Zhao (1982), basées sur le module pressiométrique, est recherchée. Des courbes de transfert de charge de type racine cubique et hyperbolique sont proposées pour tous types de pieux et de sol. La raideur des courbes proposées dépend d'une bonne estimation des valeurs ultimes de frottement et de résistance de pointe. Au contraire, la raideur initiale des courbes de Frank et Zhao est entièrement définie par le module pressiométrique, ce qui permet d'éviter des erreurs en termes de raideur. Les courbes de mobilisation proposées pour les fondations superficielles et pour les pieux sont combinées et étendues au cas des systèmes combinés. Cette méthode est implémentée comme option LTM dans le programme KID (Keller company 2015). Les prévisions avec le modèle proposé sont en très bonne adéquation avec les mesures effectuées sur 3 sites documentés dans la littérature. Une étude paramétrique montre une transition continue entre la fondation mixte et les inclusions rigides et une possibilité d'optimisation avec une diminution significative des efforts dans les colonnes et dans la fondation superficielle si un matelas est utilisé. En complément, une comparaison avec des calculs en éléments finis en 3D dans un cas théorique de semelle sur colonnes confirme que la méthode de transfert de charge développée est très performante pour des géométries simples. Une analyse de sensibilité est effectuée avec des modèles éléments finis axisymmétriques et 3D avec Plaxis (2013, 2014). Les imperfections géométriques ont principalement une incidence sur l'intégrité structurelle des colonnes non-armées de faible diamètre. Cependant, ces effets sont atténués dans les systèmes combinés en comparaison avec la colonne isolée du fait des possibilités de redistribution des charges dans le système / Rigid inclusions represent a further development of combined pile-raft foundations, comprising a load transfer platform between the columns and the structure. Calculation methods and design concepts are available for such combined systems in particular in France, based on measured pressuremeter modulus values and on the French recommendations ASIRI for rigid inclusions (IREX 2012). The conventional pile design consisting only of a bearing capacity check for the individual column cannot be applied to such combined systems. The expected settlements may be larger due to a significant load proportion supported by the soil. The present work contributes to the development of displacement-based calculation methods (advocated by the Eurocode 7, EN 1997-1 2004) and design methods for combined systems under vertical loads, in particular on an international level where in general no in situ soil modulus values are measured. Possible particularities of such systems, like the sensitivity of unreinforced small-diameter columns, also had to be investigated. The load transfer method (LTM) is identified as a straightforward engineering tool for the calculation of combined systems with relatively simple geometries. The soil-column interaction in terms of skin friction and tip resistance is described by deformation-dependent load transfer curves (or “t-z” and “q-z” curves). Continuum methods like the finite element method should be preferred only for complex cases in general. The non-linear load-settlement behaviour of single footings up to failure is analysed based on measurements given in the literature. This yields the proposal of a hyperbolic load-settlement curve for footings. This mobilization curve is defined in a way to match the linear usual method for one third of the footing ultimate load. The behaviour of single piles is investigated based on numerous available instrumented and non-instrumented pile load tests with different pile and soil types. A reliable alternative to the load transfer curves after Frank and Zhao (1982), which are based on the pressuremeter modulus, is sought. Cubic root and hyperbolic axial load transfer curves are proposed for all pile and ground types. The stiffness accuracy of the proposed curves depends on an accurate estimation of the ultimate skin friction and tip resistance values. On the contrary, the initial stiffness of the Frank and Zhao curves is fully described by the pressuremeter modulus, avoiding thus errors in the stiffness. The proposed mobilization curves for the shallow and pile foundation behaviours are combined and extended for all combined systems. The proposed method is implemented as the LTM option into the software KID (Keller company 2015). The prediction with the developed model matches very well the measurements made for 3 different cases from the literature. A parametric study shows a smooth transition between the combined pile-raft foundation case and the rigid inclusion case and a potential for optimisation with a significant reduction of the internal forces in the columns and in the rigid slab when a load transfer platform is used. In addition, a comparison with 3D finite element calculations for a theoretical footing case with columns confirms that the developed load transfer method is very reliable for simple geometries. Sensitivity investigations using the axisymmetric and 3D finite element method with Plaxis (2013, 2014) are performed. Geometrical imperfections impact mainly the structural integrity of small-diameter unreinforced columns. However, these effects are reduced in combined systems compared to the single column case due to the possibility of redistribution of the loads within the system
8

Serviceability and safety in the design of rigid inclusions and combined pile-raft foundations / Calcul des déplacements et sécurité dans le dimensionnement des fondations mixtes et inclusions rigides

Bohn, Cécilia 30 September 2015 (has links)
Les inclusions rigides sont un concept récent développé dans le prolongement des fondations mixtes, avec un matelas de transfert de charges entre les colonnes et la structure. Des méthodes de calculs et des concepts de sécurité existent pour ces systèmes combinés, notamment en France où le module pressiométrique mesuré et les recommandations ASIRI (IREX 2012) pour les inclusions rigides sont utilisés. Le dimensionnement classique des pieux basé sur une simple vérification de la portance des colonnes isolées ne peut pas être appliqué à ces systèmes combinés. Les tassements peuvent être plus importants du fait de la part significative de charge reprise par le sol. Le présent travail est une contribution au développement des méthodes de calcul et de dimensionnement en déplacement (préconisé par l'Eurocode 7, EN 1997-1 2004) pour les systèmes combinés sous charge verticale, en particulier au niveau international où des mesures in situ de module de sol ne sont généralement pas disponibles. Les éventuelles particularités de ces systèmes, notamment la sensibilité de colonnes non renforcées de petit diamètre, devaient également être examinées. La méthode de transfert de charge (“load transfer method”, LTM) est identifiée comme un outil d'ingénieur particulièrement adapté au calcul des systèmes combinés présentant une géométrie relativement simple. L'interaction sol-colonne en frottement et en pointe est définie par des courbes de transfert de charge (ou courbes “t-z” et “q-z”). Les méthodes en milieu continu comme la méthode des éléments finis sont à réserver en général aux cas complexes. Le comportement non-linéaire des semelles est examiné sur la base de mesures obtenues dans la littérature. Cette étude aboutit à la proposition d'une courbe charge-tassement hyperbolique pour les semelles. Cette courbe de mobilisation est définie de sorte qu'il y ait concordance avec la méthode linéaire habituelle pour un tiers de la charge ultime de la semelle. Le comportement de pieux isolés est étudié avec de nombreux essais de chargement instrumentés et non-instrumentés pour différents types de pieux et de sol. Une alternative aux courbes de transfert de charge selon Frank et Zhao (1982), basées sur le module pressiométrique, est recherchée. Des courbes de transfert de charge de type racine cubique et hyperbolique sont proposées pour tous types de pieux et de sol. La raideur des courbes proposées dépend d'une bonne estimation des valeurs ultimes de frottement et de résistance de pointe. Au contraire, la raideur initiale des courbes de Frank et Zhao est entièrement définie par le module pressiométrique, ce qui permet d'éviter des erreurs en termes de raideur. Les courbes de mobilisation proposées pour les fondations superficielles et pour les pieux sont combinées et étendues au cas des systèmes combinés. Cette méthode est implémentée comme option LTM dans le programme KID (Keller company 2015). Les prévisions avec le modèle proposé sont en très bonne adéquation avec les mesures effectuées sur 3 sites documentés dans la littérature. Une étude paramétrique montre une transition continue entre la fondation mixte et les inclusions rigides et une possibilité d'optimisation avec une diminution significative des efforts dans les colonnes et dans la fondation superficielle si un matelas est utilisé. En complément, une comparaison avec des calculs en éléments finis en 3D dans un cas théorique de semelle sur colonnes confirme que la méthode de transfert de charge développée est très performante pour des géométries simples. Une analyse de sensibilité est effectuée avec des modèles éléments finis axisymmétriques et 3D avec Plaxis (2013, 2014). Les imperfections géométriques ont principalement une incidence sur l'intégrité structurelle des colonnes non-armées de faible diamètre. Cependant, ces effets sont atténués dans les systèmes combinés en comparaison avec la colonne isolée du fait des possibilités de redistribution des charges dans le système / Rigid inclusions represent a further development of combined pile-raft foundations, comprising a load transfer platform between the columns and the structure. Calculation methods and design concepts are available for such combined systems in particular in France, based on measured pressuremeter modulus values and on the French recommendations ASIRI for rigid inclusions (IREX 2012). The conventional pile design consisting only of a bearing capacity check for the individual column cannot be applied to such combined systems. The expected settlements may be larger due to a significant load proportion supported by the soil. The present work contributes to the development of displacement-based calculation methods (advocated by the Eurocode 7, EN 1997-1 2004) and design methods for combined systems under vertical loads, in particular on an international level where in general no in situ soil modulus values are measured. Possible particularities of such systems, like the sensitivity of unreinforced small-diameter columns, also had to be investigated. The load transfer method (LTM) is identified as a straightforward engineering tool for the calculation of combined systems with relatively simple geometries. The soil-column interaction in terms of skin friction and tip resistance is described by deformation-dependent load transfer curves (or “t-z” and “q-z” curves). Continuum methods like the finite element method should be preferred only for complex cases in general. The non-linear load-settlement behaviour of single footings up to failure is analysed based on measurements given in the literature. This yields the proposal of a hyperbolic load-settlement curve for footings. This mobilization curve is defined in a way to match the linear usual method for one third of the footing ultimate load. The behaviour of single piles is investigated based on numerous available instrumented and non-instrumented pile load tests with different pile and soil types. A reliable alternative to the load transfer curves after Frank and Zhao (1982), which are based on the pressuremeter modulus, is sought. Cubic root and hyperbolic axial load transfer curves are proposed for all pile and ground types. The stiffness accuracy of the proposed curves depends on an accurate estimation of the ultimate skin friction and tip resistance values. On the contrary, the initial stiffness of the Frank and Zhao curves is fully described by the pressuremeter modulus, avoiding thus errors in the stiffness. The proposed mobilization curves for the shallow and pile foundation behaviours are combined and extended for all combined systems. The proposed method is implemented as the LTM option into the software KID (Keller company 2015). The prediction with the developed model matches very well the measurements made for 3 different cases from the literature. A parametric study shows a smooth transition between the combined pile-raft foundation case and the rigid inclusion case and a potential for optimisation with a significant reduction of the internal forces in the columns and in the rigid slab when a load transfer platform is used. In addition, a comparison with 3D finite element calculations for a theoretical footing case with columns confirms that the developed load transfer method is very reliable for simple geometries. Sensitivity investigations using the axisymmetric and 3D finite element method with Plaxis (2013, 2014) are performed. Geometrical imperfections impact mainly the structural integrity of small-diameter unreinforced columns. However, these effects are reduced in combined systems compared to the single column case due to the possibility of redistribution of the loads within the system
9

Numerical analysis of the reinforcement of existing foundations by the Soil Mixing technique / Renforcement de fondations existantes par Soil – Mixing - analyse par modélisation numérique

Grzyb-Faddoul, Anna Marta 22 December 2014 (has links)
L'objectif de ce travail est d'analyser l'influence du renforcement du sol par la method Soil Mixing sur le comportement des fondations superficielles et profondes. Une étude numérique a été effectuée – avec des analyses éléments finis dans ABAQUS - dans le but d'acquérir une compréhension du fonctionnement et une estimation de la performance des fondations améliorées. Pour être en mesure d'utiliser des colonnes SM pour l'amélioration de la fondation, il est nécessaire de bien comprendre leur performance sous charge axiale statique. Par conséquent, une série de simulations reproduisant des essais de chargement d'une seule colonne, et d’un groupe de colonnes ont été réalisées. Les essais à pleine et petite échelle ont été modélisés et leurs résultats comparés avec les observations expérimentales. Un bon accord entre les prédictions numériques et les mesures confirme une bonne calibration des lois constitutives des sols, des colonnes et de l’interface sol/colonne en SM. En outre, cette étude a révélé que la colonne SM agit d'une manière similaire à un pieu en béton, son comportement est régi principalement par l'interface. Ensuite, la modélisation numérique d’une fondation superficielle à petite échelle a été menée. Deux types de renforcement ont été étudiés. Le premier consiste en une seule colonne, située au centre sous la semelle analysée. Le second cas correspond à un groupe de quatre colonnes SM. Deux densités de sol ont été analysés. L'objectif de la modélisation est d'identifier l'efficacité du renforcement en termes de capacité portante de la fondation et de la réduction de son déplacement vertical. Il a été trouvé que la densité du sable a un impact significatif sur le comportement de la semelle. La variation de densité a entraîné une différence significative entre les forces totales portées par les fondations. Mais, il a été constaté que le pourcentage de la force reprise par le sol par rapport à la force total, est indépendant de la densité. L'influence du renforcement obtenu par un groupe de colonnes SM sur une fondation profonde, a été étudiée. La modélisation numérique d'un seul pieu théorique installé dans le sol homogène, a été réalisée. L'objectif de l'étude est de détecter l'impact de divers paramètres, tels que la distance horizontale entre les colonnes de SM, la distance verticale entre les têtes de colonnes et la pointe de pieu, le diamètre et la longueur des éléments SM, sur la capacité portante de la fondation. On a montré que la distance entre les colonnes et leur diamètre ont la plus grande influence sur la force de charge, la longueur de renforcement conduit à une moindre influence. / The aim of this work is to analyse the influence of soil reinforcement executed by the Soil Mixing method on the behaviour of shallow and deep foundations. Numerical investigation has been carried out - with the use of Finite Element (FE) analyses in ABAQUS - in an attempt to identify the mechanisms guiding the performance of supported foundations. To be able to use SM columns as the foundation’s improvement, it is necessary to fully understand their performance under applied static, axial load. Therefore, a set of simulations reproducing loading tests of single and group of columns have been carried out. Full and small scale tests have been modelled and their results compared with experimental observations. Good agreement between numerical predictions and measurements, confirms proper calibration of the chosen constitutive laws of: soils, columns and interactions between them. Moreover, this study has revealed that the SM column acts in a similar way to concrete pile, hence its behaviour is governed mainly by the interface. Afterwards, numerical modelling of small scale shallow foundation has been accomplished. Two kinds of reinforcement have been investigated. The first one consists of a single column situated centrally under the analysed footing. The second kind of improvement involves group of four SM columns. Two densities of soil have been analysed. The goal of the modelling is to identify the efficiency of the reinforcement in terms of: bearing capacity of the foundation and reduction of its vertical displacement. Despite significant difference between total forces borne by the foundation tested on soil with different densities, it has been found that the percentage of the total force that was taken by the soil is density independent. The influence of reinforcement executed by group of SM columns on a deep foundation has been studied. Numerical modelling of a theoretical, single pile, installed in homogeneous soil, has been carried out. The aim of the investigation is to detect the impact of parameters such as: pattern of reinforcing elements, horizontal distance between SM columns, vertical distance between columns’ heads and tip of the pile, diameter and length of SM elements, on the bearing capacity of the foundation. It has been found that the distance between columns and their diameter has the biggest influence on the borne force. However, the length of the reinforcement has shown the least significant influence.
10

Conception des fondations superficielles reposant sur des sols granulaires en utilisant la vitesse des ondes de cisaillement

Bouassida, Wafi January 2015 (has links)
Un bon dimensionnement d’une fondation superficielle nécessite une bonne caractérisation du sol sur lequel elle reposera. Pour le cas des sols granulaires, les essais de reconnaissances destructifs (SPT, CPT, etc.) impliquent la conversion des profils obtenus du sol exploré en un profil de rigidité afin de pouvoir estimer sa portance. Une telle tâche peut induire des erreurs au niveau de l’estimation étant donné qu’elle nécessite le passage d’un nombre de paramètres (N, qc) n’illustrant pas l’état réel du sol (rigidité) à des paramètres caractérisant sa performance (module élastique, coefficient de Poisson). La caractérisation des sols granulaires en utilisant la vitesse des ondes de cisaillement (non destructive) nous permet de contourner ce problème étant donné qu’elle nous donne directement la variation d’un paramètre intrinsèque au sol (Vs) à partir duquel il est possible d’effectuer le dimensionnement. La disponibilité d’une technique de mesure de vitesses de cisaillement (P-RAT) sur des échantillons de sols au laboratoire géotechnique de l’UdeS, nous a permis de mettre en œuvre l’application de Vs dans l’estimation de la portance des sols granulaires. Au cours de ce mémoire, une procédure servant à estimer le tassement des fondations superficielles reposant sur des dépôts granulaires est présenté. Les paramètres de cisaillement (Vs, G) d’un sable déterminés à l’aide des essais de caractérisation (P-RAT) ont été utilisés pour construire un modèle numérique de fondation. La consistance des résultats numériques du modèle a été confirmée à travers des essais de chargement de plaque. Ce travail montre donc l’importance des paramètres de cisaillement dans la modélisation d’une application fréquente en géotechnique. Il constitue un départ considérable pour la construction de relations constitutives basées sur le paramètre vitesse de cisaillement.

Page generated in 0.4843 seconds