• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 91
  • Tagged with
  • 92
  • 61
  • 28
  • 25
  • 23
  • 21
  • 20
  • 15
  • 15
  • 13
  • 13
  • 11
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

An?lise fotoel?stica da influ?ncia da aplica??o de carga no padr?o de distribui??o de tens?es em implantes dent?rios

Barbieri, Guilherme Machado 17 January 2013 (has links)
Made available in DSpace on 2015-04-14T13:30:24Z (GMT). No. of bitstreams: 1 448372.pdf: 1689966 bytes, checksum: 48a67133718d201e5dec9cece771f87c (MD5) Previous issue date: 2013-01-17 / The aim of this study was to evaluate and compare stress distribution around implants using platform switching technique with conventional diameters, using the photoelasticity method in internal and external hex-type implants. Five models were fabricated using photoelastic resin kit FLEXIBLE G3 (POLIPOX Ind. E Com, Sao Paulo Brazil) with a single-body implant in each of them. These models were as follows: MODEL A - 4.1mm platform with 4.1mm external hex implant-abutment connection; MODEL B - 5.0mm platform with 4.1mm external hex implant-abutment connection; MODEL C - 5.0mm platform with 5.0-mm external hex implant-abutment connection; MODEL D - 4.5mm platform with 4.5mm internal hex implant-abutment connection; and MODEL E - 4.5mm platform 3.8mm internal hex implant-abutment connection. An axial load of 100N was applied in a plane polariscope to verify isochromatic fringes. The images were photographed with a digital camera CANON EOS DIGITAL REBEL XTI and viewed with software specially developed for this study. The values for total maximum shear stress for implant HISW was 20.16 kPa, HI 20.64 kPa, 21.84 kPa HESW, HE 21.70 kPa and 20.74 kPa for control implant. The internal hex implant showed better load distribution and lower stress values when the platform switching technique was used and no system was able to eliminate stress on some thirds. / O objetivo deste estudo foi avaliar e comparar a distribui??o de tens?es de implantes utilizando a t?cnica da plataforma switching com os di?metros convencionais, atrav?s do m?todo da fotoelasticidade, em implantes do tipo hex?gono externo e hex?gono interno. Cinco modelos foram constru?dos com a resina fotoel?stica KIT FLEX?VEL G3 (POLIPOX Ind. E Com., S?o Paulo Brasil), com um implante unit?rio em cada um deles. Estes modelos foram MODELO A plataforma de 4.1mm HE/pilar de 4.1mm, MODELO B plataforma de 5.0mm HE/pilar de 4.1mm, MODELO C plataforma de 5.0mm HE/ pilar de 5.0mm, MODELO D plataforma de 4.5mm HI/pilar de 4.5mm e MODELO E plataforma de 4.5mm HI/pilar de 3.8mm. Uma carga axial de 100N foi aplicada em um polarisc?pio plano para a verifica??o da franjas isocrom?ticas. As imagens foram fotografadas com uma c?mera digital CANON EOS DIGITAL REBEL XTI e visualizadas com o software especialmente desenvolvido para este trabalho. Os valores de tens?o m?xima cisalhante total para o implante HISW foi de 20,16KPa, HI 20,64KPa, HESW 21,84KPa, HE 21,70KPa e para o implante controle 20,74KPa. O implante de hex?gono interno apresentou uma melhor distribui??o de carga e menores valores de tens?o com a utiliza??o da t?cnica plataforma switching, sendo que nenhum sistema foi capaz de eliminar tens?o em algum dos ter?os.
22

Análise fotoelástica de tensões transmitidas a implantes curtos / Photoelastic analysis of tensions transmitted to short implants

Oliveira, Janisse Martinelli Borges de 18 August 2011 (has links)
O objetivo desse trabalho foi avaliar, pelo método fotoelástico, de que maneira cargas aplicadas sobre próteses metalocerâmicas implantossuportadas eram transmitidas a implantes de diferentes comprimentos, e como a proporção coroa/implante influenciaria essa distribuição de tensões. A partir de quatro modelos mestres em resina do tipo policarbonato foram confeccionados quatro modelos em resina fotoelástica (Araldite) simulando extremidade livre mandibular, com o dente 44 em resina (Luxatemp) e os dentes 45, 46 e 47 substituídos por implantes com 4 mm de diâmetro. O grupo 1 (G1) foi formado por 2 implantes de comprimento convencional ou longo (11 mm; Titamax Cortical CM, Neodent) substituindo o 45 e o 46, e 1 implante curto (5 mm; Ws Cortical CM, Neodent) substituindo o 47. O grupo 2 (G2) apresentava 1 implante com 11 mm (45) e 2 implantes com 5 mm (46 e 47). O grupo 3 (G3) foi reabilitado por 3 implantes de 5 mm e o grupo 4 (G4) por 3 implantes de 11 mm de comprimento. Nos grupos com implantes de 5 mm foi simulada reabsorção óssea de 4 mm de altura. Coroas metalocerâmicas unidas foram parafusadas sobre os minipilares intermediários. Foram realizados diferentes carregamentos oclusais sobre as coroas: oclusal balanceado de 150N, puntiforme de 100N na mesial do 45 e puntiforme de 100N na distal do 47. Análise fotoelástica quantitativa determinou a tensão transmitida (MPa) nos grupos: G1 (84.73), G2 (136.36), G3 (126.77) e G4 (164.72) para a carga oclusal balanceada; G1 (91.66), G2 (70.93), G3 (93.08) e G4 (119.82) para a carga na mesial do 45; e G1 (75.22), G2 (70.88), G3 (93.79) e G4 (117.56) para a carga na distal do 47. Para os implantes curtos, em todos os casos, a proporção coroa/implante foi maior que 2,5 e para os implantes de comprimento convencional essa proporção foi 1, em média. Após as análises realizadas, foi possível concluir que os maiores valores de tensões foram encontrados no grupo com 3 implantes longos (G4), e o aumento da proporção coroa/implante não mostrou correlação com maior concentração de tensões. Comparativamente, a utilização de implantes curtos reduziu as tensões transmitidas ao redor dos implantes. / The aim of this study was to evaluate by the photoelastic method, stress transmission to implants of different lengths by metal-ceramic crowns under different loads, and how crown/implant ratio influenced this stress distribution. From four matrixes, four photoelastic models (Araldite) were made simulating free mandibular end, with teeth 44 in resin (Luxatemp) and tooth 45, 46 and 47 replaced by implants with 4 mm in diameter. Group 1 (G1) was formed by two implants with conventional length or long (11 mm; Titamax Cortical CM, Neodent) replacing tooth 45 and 46, and one short implant (5 mm; Ws Cortical CM, Neodent) replacing the 47. Group 2 (G2) had one implant with 11 mm (45) and 2 implants with 5 mm (46 and 47). Group 3 (G3) was rehabilitated by three implants of 5 mm and group 4 (G4) for 3 implants of 11 mm in length. In the groups with 5 mm implants was simulated 4 mm bone resorption in height. Metal-ceramic fixed prosthesis was bolted on the abutments. Different oclusal loads were performed over the crowns, 150N in occlusal balanced, 100N on the 45 mesial, and 100N on the 47 distal. Quantitatively photoelastic analysis determined the stress transmitted (MPa) on the groups: G1 (84.73), G2 (136.36), G3 (126.77) and G4 (164.72) for the occlusal load balanced, G1 (91.66), G2 (70.93), G3 (93.08) and G4 (119.82) for charging on the 45 mesial, and G1 (75.22), G2 (70.88), G3 (93.79) and G4 (117.56) to the load on the 47 distal. Crown/implant ratio for short implants was greater than 2.5 and for long implants was about 1. After analysis, it was concluded that the highest values of strains were found in the group with three long implants (G4), and the increased crown/implant ratio showed no correlation with the highest stress concentration. Comparatively, the use of short implants reduced stress around the implants.
23

Estudo da transmissão e distribuição de tensões aplicadas à resina acrílica convencional e acrescida de fibras através do método fotoelástico / Study of tension transmission and distribution applied upon acrylic conventional resin and strengthened by fibers through photoelastic method

Andréa Gomes de Oliveira 08 August 2007 (has links)
A resina acrílica encontra-se entre os materiais mais utilizados na odontologia. Apesar de suas qualidades, o polimetilmetacrilato ainda mostra-se um material com resistência comprometida. Para tanto, diversos reforços têm sido propostos na literatura e entre eles encontram-se as fibras de vidro e aramida. Apesar de acrescerem na resistência da matriz acrílica pouco se sabe sobre como os esforços aplicados sobre a resina reforçada por fibras são transmitidos e distribuídos às áreas de sustentação, o que motivou a realização deste estudo. Foram confeccionados dez corpos-de-prova em resina acrílica termopolimerizável divididos em cinco grupos segundo o reforço utilizado: fibras de vidro filamentares tratadas por imersão no monômero acrílico (Grupo F), fibras de vidro em malha submetidas ao mesmo tratamento (Grupo M), fibras de vidro trançadas com aramida e tratadas por imersão na mistura monômero/polímero (Grupo H) e fibras de vidro trançadas com aramida e tratadas por silanização (Grupo HS). Como grupo controle (C) foram utilizadas amostras de resina acrílica termicamente ativada sem a associação de fibras de reforço. Após a adaptação dos corpos-de-prova à matriz fotoelástica os mesmos foram submetidos a ensaio de flexão através da Máquina Universal de Ensaios (EMIC-modelo DL 2000, S. J. dos Pinhais, PR, Brasil) acoplada ao Polariscópio Circular (Desenvolvido na Faculdade de Engenharia Mecânica - UFU, Uberlândia, MG, Brasil). Os resultados mostraram valores para a Energia de Distorção, em Kgf/mm2, de 223,124 para o grupo F; de 218,710 para o grupo H; 217,692 para o grupo M; 215,810 para o grupo HS e de 210,122 para o grupo C. Também foi observado que a energia de distorção apresentou distribuição homogeneamente crescente em todos os grupos estudados. Concluímos que a associação de fibras à resina acrílica gerou aumento da energia acumulada na área de sustentação protética sendo que os maiores valores foram observados para o grupo de fibras de vidro filamentares. Observamos também que a silanização da fibra híbrida contribuiu para uma menor transmissão de tensão à matriz fotoelástica. / Acrylic resin is found among the most used materials in dentistry. Despite its qualities, the polymetilmetacrylate yet shows itself as a material with questionable resistance. Therefore, lots of reinforcements have been proposed in literature and among them we find glass fibers and aramid. Although they add to the resistance of the acrylic matrix, little is known about how the efforts applied upon the resin strengthened by the fibers are transmitted and distributed over the sustaining areas, which motivated the course of this study. Ten specimens made of termcured acrylic resin were created and divided into five groups according to the reinforcement used: roving glass fibers treated by immersion in the acrylic monomer (Group F), mesh glass fibers given the same treatment above (Group M), glass fibers braided with aramid and treated by immersion in the blending momer/polimer (Group H) and glass fibers braided with aramid and treated by signalization (Group HS). As control group (C) were used samples of acrylic resin termically activated without the addition of fibers. After adapting the specimens to the photoelastic matrix, the former were submitted to flexural tests through the Universal Machine of Rehearsal (EMIC-model DL 2000, S. J. Dos Pinhais, PR, Brazil) joint to the Circular Polariscope ( developed in the Mechanical Engineering College ? UFU, Uberlândia, MG, Brazil. The results show values to the Distortion Energy, in Kgf /mm2, of 223,124 for group F; 218,710 for group H; 217,692 for group M; 215,810 for group HS and 210,122 for group C. It was also observed that the distortion energy presented homogeneous growing distribution in al the groups studied. We conclude that the association of fibers to the acrylic resin generated an increase of the energy accumulated in the area of prosthetic support, thus the highest values were observed in the group with roving glass fibers. We noticed that the silanization of the hibrid fiber contributed to a smaller tension transmission to the photoelastic matrix.
24

[en] PHOTOELASTIC ANALYSIS OF BIRREFRINGENT AND ORTHOTROPIC COMPOSITES / [pt] ANÁLISE DE TENSÕES EM MATERIAIS CONJUGADOS BIRREFRINGENTES

ROGERIO ATHAYDE ANTONELLI 22 October 2012 (has links)
[pt] Este trabalho procura estudar materiais compostos constituídos por uma matriz de resina poliéster reforçada por fibras de vidro, com propriedades de ortotropia, transparência e birrefringência, através do desenvolvimento de métodos apropriados para a sua obtenção e sua caracterização mecânica e ótica. O material foi obtido a partir de um tipo de fibra de vidro disponível no mercado nacional: fio Roving 374, da Ocfibras, que serviu de reforço à resina poliéster Crystic 199PA rígida, comercializada pela Leo Glass, que constituiu a matriz. O material desenvolvido teve ambos comportamentos mecânico e ótico estudados através de diversos modelos sujeitos a estados uniaxiais e biaxiais de tensões. A discussão dos resultados obtidos e do método de análise experimental empregado, conhecido como foto elasticidade ortotrópica, levou à conclusão que este método pode ser aplicado com uma precisão razoável (mais ou menos 20 por cento), a despeito das dificuldades relativas à interpretação da resposta ótica do material, que depende da transparência do mesmo e da existência de baixas tensões residuais elásticas. / [en] The present work aims to study composite materials, more precisely, certain type of reinforced fiberglass polyester resin with orthotropic, birefringent and transparency properties, through the development of appropriate methods for its mechanical and optical characterization. A kind fiberglass available on the Brazilian market was used: roving 374, (by Ocfibras) which was combines with crystic 199 P.A rigid resin matrix (by Leo Glass). Both mechanical and optical behaviors were studied through several models subjected to uniaxial and biaxial states of stress. The discussion of the results and of the experimental methods used leaded to the conclusion that this method reached good resolution – of a maximum of 20 per cent – in spite of difficulties reached in interpreting the optical response this is a function of both material’s transparency and residual elastic stresses.
25

Avaliação do uso de fotoelasticidade de reflexão no estudo de ligação metálica viga-coluna

Fiorini, Cesare 11 November 2016 (has links)
Submitted by Cesare Fiorini (gerson.fiorini@gmail.com) on 2017-01-13T13:37:10Z No. of bitstreams: 1 DISSERTAÇÃO_Cesare Fiorini.pdf: 10365608 bytes, checksum: 10cda96f30689edb43a511848179819f (MD5) / Approved for entry into archive by Flávia Sousa (flaviabs@ufba.br) on 2017-01-13T16:38:14Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_Cesare Fiorini.pdf: 10365608 bytes, checksum: 10cda96f30689edb43a511848179819f (MD5) / Made available in DSpace on 2017-01-13T16:38:14Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_Cesare Fiorini.pdf: 10365608 bytes, checksum: 10cda96f30689edb43a511848179819f (MD5) / CAPES / A fotoelasticidade é uma das técnicas experimentais mais antigas. Nova atenção é dada hoje a esse método devido aos progressos da fotoelasticidade digital. Nessa dissertação é apresentada o estudo de uma ligação metálica, constituída por uma viga perfil I em balanço, ligada a coluna por meio de solda e parafusos, e sujeita a carregamento concentrado na extremidade livre. O objetivo principal desse estudo é analisar a junção metálica com a fotoelasticidade de recobrimento e avaliar a aplicabilidade dessa técnica por esse tipo de conexão. Sucessivamente são expostos os fundamentos teóricos junto com a formulação matemática da fotoelasticidade clássica e as evoluções alcançadas pela fotoelasticidade digital. Foram apresentados, também com base na literatura, os princípios teóricos do método aos elementos finitos assim como do processamento e análise digital de imagens no espaço de cor RGB, além de descrever as características das ligações metálicas com base nas normativas técnicas. A metodologia aplicada envolveu a análise teórica, experimental e numérica. O arranjo experimental é constituído por um polariscópio circular em campo escuro e com luz branca. Nos ensaios de laboratório foram produzidas manualmente as lâminas fotoelásticas em Araldite, assim como foram realizados os testes de calibração sobre os espécimes. Os testes de flexão simples sobre o corpo de prova foram executados com quatro níveis de carga. As regiões investigadas foram a mesa superior da viga, a alma e a chapa de topo. Foi feito um registro fotográfico para analisar a distribuição das franjas isocromáticas nas regiões investigadas e determinar as diferenças das tensões principais. Paralelamente foi desenvolvido um programa de tratamento de imagem, escrito em Matlab®, capaz de fornecer o valor da constante fotoelástica, para o tipo de modelo mecânico utilizado. A solução numérica, em regime elástico-linear, foi produzida com a proposta de um código escrito em Ansys®. Na mesa superior a resposta numérica comparada com a experimental mostrou um erro menor a 10 % em termos de estado de tensões. Mostra-se também o potencial didático dessa técnica com a proposta de alguns exercícios. / ABSTRACT: Photoelasticity is one of most ancient experimental techniques for stress analysis. New attention is given to this method due to progress of digital photoelasticity. This dissertation investigates a mixed steel junction beam-column by using reflection photoelasticity. A cantiliver beam I profile, bolted and welded to column, is subject to concentrated load on free extreme. Main proposal is to analyse the steel junction and assess feasibility of this technique for this kind of connection. Successively, theoeritical foundation is exposed with mathematical formulation of classic photoelasticity. Progress has been reached by digital photoelasticity. Based on literature, theoretical principles of finite element method were exposed, as well as digital image processing and analysis, in RGB colour space. Besides, caracteristics of steel junction are described with base on technical normative. The applied methodology used theoretical, experimental and numeric analyis. Experimental equipment used is a circular polariscope in black field with white light. In laboratory test photoelastic film in Araldite were prepared by hand, such as were made calibration setup testing of photoelastic film on especimens. Simple bending tests were applied wtih four level of loads on the model. Investigated areas were beam upper flange, beam web and beam plate. A photographic register was made to analyse distribution of isocromatic fringes and determinate principal stress difference. In parallel, a non comercial algorithm, written in Matlab®, process data to determinate the fringe value photoelastic constant. The finite element numerical analysis was realized considering elastic-linear conditions and was written with commercial software ANSYS®. On the beam upper flange numerical and experimental results showed a difference lower than 10 % as stress state. Didactic potential associated to this technique is showed with a proposal of some exercises.
26

Desenvolvimento de um programa computacional visando o aprimoramento do uso da técnica da fotoelasticidade

Perosa, Eduardo Ávila January 2013 (has links)
Made available in DSpace on 2013-10-11T13:35:43Z (GMT). No. of bitstreams: 1 000451033-Texto+Completo-0.pdf: 4023283 bytes, checksum: f5ff6b363661cfa2b354502e0156edb5 (MD5) Previous issue date: 2013 / Photoelasticity is an important technique to the mechanics stress analysis in complex geometry structures and exposed to equally complex loads. Such technique is based in the principle in which some materials present different refraction index when subjected to load. When the part is crossed by a polarized light beam in the opposite face it is possible to visualize colored fringes whose appearance is related to the stress to which the structure is exposed. The analysis of the colored fringes image of the part is an indirect measure of mechanical stress. Despite the advances in photoelasticity, it is still widely used the semiquantitative analysis by calculating the stress in the part to pre-determined points which somehow submits the colors analysis to the inaccuracy from the human eye, compromising repeatability and reproducibility of the experiment. In order to overcome this adversity, software was developed for analysis of the entire image area through the univocal identification of the colors of the fringes. The software was developed using the basic concepts of image processing such as connectivity pixels and edge detection, besides a design using a color space created by the International Commission on Illumination. Using this computational tool, it was possible to obtain results of the average shear stress in the structure from the analysis of all pixels in the image, something almost inconceivable to be manually done by the traditional methodology. / A fotoelasticidade é uma importante técnica para análise de tensões mecânicas em estruturas de geometria complexa e expostas a cargas igualmente complexas. Esta técnica baseia-se no princípio de que alguns materiais apresentam diferentes índices de refração quando submetidos a esforços mecânicos. Quando a peça é atravessada por um feixe de luz polarizado, na face oposta podem ser visualizadas franjas coloridas cujo aspecto é relacionado à tensão a qual a estrutura está exposta. A análise destas franjas coloridas da imagem da peça é uma medida indireta da tensão mecânica. Apesar dos avanços na fotoelasticidade, ainda é muito utilizada a análise semiquantitativa calculando-se a tensão na peça em pontos pré-determinados, o que de certo modo submete a análise das cores a inacurácia do olho humano, comprometendo a repetitibilidade e reprodutibilidade do experimento. A fim de superar esta adversidade foi desenvolvido um programa para análise de toda a área da imagem passando pela identificação unívoca das cores das franjas. O programa foi desenvolvido utilizando-se conceitos básicos de processamento de imagens como conectividade de pixels e detecção de borda, além de uma concepção utilizando-se um espaço de cor criado pela Comissão Internacional de Iluminação. Com o uso desta ferramenta computacional foi possível obter resultados da tensão de cisalhamento média na estrutura a partir da análise de todos os pixels da imagem, algo praticamente inconcebível de ser feito manualmente pela metodologia tradicional.
27

Analise das tensões na estrutura de suporte em protocolos implanto-suportados com alteração do numero e diametro das fixações / Analysis of alteration the number and diameter on stress transfer by protocols implant-supported prostheses

Simamoto Junior, Paulo Cezar 05 September 2008 (has links)
Orientadores: Mauro Antonio de Arruda Nobilo, Flavio Domingues das Neves / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T04:15:45Z (GMT). No. of bitstreams: 1 SimamotoJunior_PauloCezar_D.pdf: 7244297 bytes, checksum: 461e6361f9cf09516a4a12eb25ad2ccb (MD5) Previous issue date: 2008 / Resumo: Este trabalho teve por objetivo quantificar e qualificar in vitro às tensões geradas pela da alteração do número e do diâmetro de implantes dentários em protocolos clássicos tipo Brånemark, em implantes fixados em modelo aproximado da região anterior da mandíbula, entre os forames mentonianos por meio da técnica da fotoelasticidade. Foram confeccionadas nove infra-estruturas em titânio, utilizando a distribuição para os implantes posteriores e centrais, similares ao sistema Brånemark Novum®. Foram divididos três grupos: Grupo Controle (GC) com cinco implantes de 3,75mm de diâmetro; Grupo Regular (GR) com três implantes de 3,75mm de diâmetro e Grupo Largo (GL) com três implantes de 5mm de diâmetro, com comprimento padronizado de 13mm para todos os implantes. Nove modelos fotoelásticos foram confeccionados, com três paredes planas, o que permitiu a quantificação das tensões em cada implante, por meio da técnica fotoelástica de transmissão plana, na presença de carregamento constante de 1,33kgf em um dos extremos livres da prótese. Para análise das tensões, foi utilizado polariscópio circular, avaliando dezesseis pontos ao longo do corpo dos implantes. Os valores encontrados para tensão cisalhante (t), com relação ao aumento do diâmetro dos implantes, demonstraram diminuição da concentração de tensão em 8% para a região crítica do sistema, extremos livres, quando comparado a GC, sendo em GR encontrada as maiores médias de tensão cisalhante (t). O número de implantes mostrou-se menos relevante na diminuição das tensões para o modelo estudado, contudo o aumento do diâmetro otimizou a distribuição das tensões em comparação a GC / Abstract: The aim of this study was to evaluate the influence in vitro of the change in the number and diameter of dental implants in Brånemark protocols. Nine infrastructure in titanium, with approximate measures of the protocol type Brånemark Novum® and divided into three groups: Control Group (CG) with five implants, 3.75mm in diameter; Regular Group (RG), with three implants, 3.75mm in diameter and Wide Group (WG), with three implants and 5mm in diameter, all implants have 13mm length. The analysis of the gradient of stress was done by the photoelastic analysis, using nine photoelastic models prepared to simulate the previous region of the lower jaw-bone. The models were fitted to support and brought to the polariscope, with loading of 1.33 kgf in one of the cantilevers. They were examined 16 points distributed to about 1mm in outer contour of the implants. The values found for tensile stress shear stress (t), showed that the diameter of the implants (WG) affect the distribution of tensions in the experimental model, decreasing 8% the absolute best and distributing tensions by GC. The RG presented larger absolute values of tension. The number of implants factor showed smaller decrease of the stress for the studied model however the increase of the diameter optimized the distribution of the stress in relation to control grou / Doutorado / Protese Dental / Doutor em Clínica Odontológica
28

Análise fotoelástica da distribuição de tensões geradas por carregamento em coroas unitárias suportadas por implantes curto e longo / Photoelastic analysis with different width and height crown loaded over short and long single dental implant

Carvalho, Breno Carnevalli Franco de, 1963- 12 September 2013 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T03:25:43Z (GMT). No. of bitstreams: 1 Carvalho_BrenoCarnevalliFrancode_D.pdf: 2254429 bytes, checksum: 0864903c9e5a5e409b843fd792284ecc (MD5) Previous issue date: 2013 / Resumo: Implantes curtos são utilizados em situações clínicas quando a altura e/ou a espessura óssea são insuficientes. A proposta neste estudo foi verificar por meio da análise de tensão fotoelástica a influência exercida pela altura e largura da coroa protética na força transmitida aos implantes curto (7 mm) e longo (13 mm) quando o carregamento foi efetuado no centro ou na extremidade das coroas. As dimensões da altura e da largura da coroa simulada foram estabelecidas com base nas dimensões de dentes pré-molar e molar inferiores humanos e a espessura estabelecida em 6 mm. O corpo-de-prova de resina fotoelástica foi feito com o sistema bi componente à base de resina epóxi modificada e endurecedor. Os carregamentos foram de 0,4 kgf no centro e de 0,3 kgf numa das extremidade da coroa. A análise fotoelástica avaliando as ordens de franjas ao redor dos implantes foi feita com polariscópio de transmissão. Cada fotografia foi analisada três vezes no programa Fringes para ordens de franja de 0 a 4, considerando as médias da ordem das franjas e da tensão cisalhante para cada ponto estabelecido no modelo. Os dados foram submetidos à ANOVA dois fatores e diferenças estatísticas comparadas pelo teste t de Student em nível de significância de 5%. Os resultados mostraram que não houve diferença entre os níveis de tensões gerados pela altura e largura das coroas protéticas sobre os implantes curto e longo, quando os carregamentos foram feitos tanto no centro como na extremidade das coroas. Concluiu-se que as tensões geradas sobre os implantes curto e longo foram similares qualquer que fosse o tamanho e o local dos carregamentos aplicados sobre as coroas; houve diferença na magnitude da tensão exercida sobre os implantes curto e longo, sendo maior para o implante curto / Abstract: Short implants are used in clinical situations when the mass of bone is deficient in height and/or thickness. The purpose of this study was to verify the height and width crown influence in the stress transmission in short (7mm) and long (13mm) implants when loaded at center and edge of the crown. The simulated crown dimensions were established using a natural premolar and molar crown dimensions and the thickness was 6 mm. The photoelastic models were made using a dual system based on modified epoxi resin and catalyser. The crowns were loaded with 0,4 kgf at the center and 0,3 kgf at the edge. The photoelastic analysis for fringe order around the implants was made using a transmission polariscope. The maximum shear stress and the fringe values from 0 to 4 were determined in each photography measured three times using Fringes software. Two-way ANOVA and t Student test at 5% significance were perfomed. The results showed no difference in the stress levels produced by different height and width crown over the short and long implants when loaded both center and edge of the crowns. In conclusion, the results showed similar stress on the short and long implants regardless the size and the loaded crown area; however, there was statistical difference in the stress level on the implants being higher for the short implant / Doutorado / Protese Dental / Doutor em Clínica Odontológica
29

Analise fotoelastica da distribuição de tensões produzida na mandibula pela simulação dos esforços mastigatorios em proteses fixas em "cantilever" implanto-suportadas - estudo "in vitro"

Vaz, Marcos Andre Kalabaide 18 June 1999 (has links)
Orientador: Altair Antoninha Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T05:48:51Z (GMT). No. of bitstreams: 1 Vaz_MarcosAndreKalabaide_D.pdf: 3759338 bytes, checksum: 7c236aca974ddaa171bffd6559a36b2f (MD5) Previous issue date: 1999 / Resumo: Este estudo verificou a distribuição de tensões na mandíbula pela simulação dos esforços mastigatórios em próteses fixas em "cantilever" implanto-suportadas. Foram confeccionadas 12 réplicas de mandíbulas, a partir da usinagem de um bloco de resina fotoelástica PLM-48 (Photolastic Inc., Raleigh, USA), nos quais foram instalados um par de implantes Restare (Lifecore, Chaska, USA) individualmente. Fixou-se implantes de 4 mm de diâmetro, variandose o comprimento dos mesmos, dividindo-os em 4 grupos: grupo I, um par de implantes de 11,5 mm de comprimento; grupo II, implantes de 13 mm de comprimento; grupo III, implantes de 15 mm e grupo IV, implantes de 18 mm. Estes implantes foram posicionados na região dos 2 pré-molares inferiores e sobre estes, foi confeccionada uma prótese fixa com pôntico distal em "cantilever" que permitiu a aplicação do carregamento em 5, 10, 15 e 20 mm nesta extensão. O carregamento foi aplicado com um dispositivo mecânico e calibrado por um dinamômetro (89 N). Cada conjunto foi levado individualmente ao polariscópio de transmissão (Série 080) para a visualização e interpretação das franjas fotoelásticas, obtendo-se desta maneira, valores numéricos que correspondem a ordem de franja para cada ponto marcado previamente nas réplicas. Concluiu-se que: 1) Os quatro grupos testados apresentaram padrões semelhantes quanto à distribuição de tensão quando submetidos à carga de 89 N. Porém, diferiram quanto à intensidade. 2) Quanto mais distante o ponto de aplicação do carregamento no "cantilever", maior a tensão transmitida à resina fotoelástica. 3) A concentração de tensão mais evidente deu-se na região inter-implantes, independentemente do comprimento do implante ou do "cantilever" / Abstract: This study verified tension distribution in the mandibular bone by masticatory efforts simulation on cantilever implant supported fixed prosthesis. Twelve mandibular bone replicas were obtained by milling a photoelastic material block (pLM-4B, Photoelastic Inc., Raleigh, USA). A pair of Restore implants (Lifecore, Chaska, USA) was insta1led on each resin replica. Four millimeter in diameter implants of various lengths were fixated and were divided into 4 groups. Group L a pair of 11,5 mm implants; Group 11, a pair of 13 mm implants; Group III, a pair of 15 mm implants and Group IV, a pair of 18 mm implants. These implants were positioned on the lower second pre-molars region. A fixed prosthesis was fabricated with cantilever distal pontic and was placed, over the implants, which allowed load application on 5, 10, 15 and 20 mm of the cantilever's extension. The load was applied with a mechanical device which was calibrated with a dynamometer at 89 N. Each set was individually taken to a transmission polariscope (Series 080) for visualization and interpretation of photoelastic fringes. Numerical values of finges order were obtained for each pre-determined point in the replicas. It could be concluded that: 1 )The four tested groups showed similar patterns of tension distribution when submitted to a 89 N load application. But they were different in relation to intensity. 2) The farther the point of load application on the cantilever, the greater the transmitted tension to the photoelastic resin. 3) There was a greater tension concentration at the inter-implant region, which did not depend on the implant or cantilever length / Doutorado / Protese Dental / Doutor em Clínica Odontológica
30

Analise fotoelastica da distribuição de tensões em proteses totais fixas implanto-suportadas

Bastos, Poliana Lima 25 February 2005 (has links)
Orientador: Mauro A.A. Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:50:29Z (GMT). No. of bitstreams: 1 Bastos_PolianaLima_M.pdf: 3116472 bytes, checksum: 1ef54b4bfd3a59b4b3d79ac8ff9a99e7 (MD5) Previous issue date: 2005 / Resumo: Este trabalho avaliou, por meio de análise fotoelástica, a distribuição de tensões ao redor de implantes que suportam próteses totais fixas. O modelo foi confeccionado com resina fotoelástica PL-2 (Vishay Measurements Group, USA), onde foram posicionados seis implantes de 3,75 X 11mm (Conect AR, Conexão Sistemas de Prótese, São Paulo, SP). Foram avaliadas dois sistemas de próteses totais fixas: o protocolo convencional de Brânemark , onde foi confeccionada uma estrutura em titânio (GI) e a prótese fixa destacável (Gil), também confeccionada em titânio, com acréscimo de dois attachments (MK1 Universal Attachments, Sande, Germany). Para os dois grupos, utilizou-se a técnica do cilindro cimentado, na qual cilindros pré-fabricados foram cimentados à estrutura metálica. Inicialmente, as estruturas foram avaliadas quanto às discrepâncias marginais em microscópio óptico com precisão de 0,5/lm e aumento de 120x (UHL VMM-100-BT; Renishaw; UK) associado a um equipamento de leitura digital (Quadra-Check 200; Metronics Inc, Canadá). O método fotoelástico com polariscópio circular foi utilizado para avaliar a distribuição de tensões após prova da estrutura metálica e instalação da prótese, bem como para registrar esse comportamento, por meio de fotografias. Um carregamento oclusal de 100N foi aplicado em 3 pontos individualmente: A (região distal do segundo pré-molar direito), B (regiãodistal do segundo pré-molar esquerdo) e C (região palatina, entre os incisivos centrais). Para as discrepâncias marginais, o GI exibiu menor desajuste (52,1Oum) em relação ao Gil (66, 49um). Os resultados fotoelásticos não mostraram diferenças significativas entre os dois grupos. Observou-se maior concentração de tensões na cervical, no corpo e no ápice dos implantes anteriores, enquanto que nos implantes posteriores, houve maior concentração na região apical. Além disso, o padrão de franjas aumentou gradativamente como resultado da seqüência dos procedimentos laboratoriais. A distribuição de tensões mostrou-se similar entre a prótese do tipo protocolo convencional de Brânemark e a prótese fixa destacável / Abstract: The present study evaluated the stress distribution around osseointegrated implants restored with complete fixed dentures by photoelastic analysis. A photoelastic model of an edentulous maxilla was fabricated (PL-2; Vishay Measurements Group, USA) with 6 implants 3.75x11mm (Conect AR; Conexao Sistema de Protese, Sao Paulo, Brazil). Two complete fixed dentures were evaluated: the conventional Branemark protocol-type rehabilitation technique (GI) with cast titanium framework; and, a fixed-detachable denture (Gil) made from cast titanium incorporating 2 attachments (MK1 Universal Attachments, Sande, Germany). For both groups, the frameworks were manufactured using the cemented-cylinder incorporation technique, where pre-fabricated prosthetic cylinders were cemented to the castings. Initially, ali the frameworks were evaluated for marginal discrepancies in a 0.5mm-accurate optical traveling microscope x120 magnification (UHL VMM-100-BT; Renishaw, UK) equipped wit a digital measurement read-out system (Quadra-Check 200; Metronics Inc, Canada). The photoelastic method with a circular polariscope was used to evaluate the stress distribution after the try-in and installation of the frameworks on the implants. Loads of 100 N were applied to specific points of the frameworks: A (right posterior second pre-molar), B (left posterior second pre-molar) and C (palatal to central incisors). Photographs were taken from the photoelastic fringes after loading around the implants with different magnifications. For marginal discrepancies, the GI exhibited lower gaps (52.10um) than Gil (66.49um). Regarding to the stress distribution, no significant differences were found between the groups. A transfer of load was observed in apical, distal and mesial regions in the anterior implants. For posterior implants, stress was concentrated in the apical regions. The tensions produced around the implants were gradually increased as the laboratorial procedures were accomplished. Stress distribution was similar to conventional Branemark protocoltype and fixed-detachable dentures / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0797 seconds