• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 91
  • Tagged with
  • 92
  • 61
  • 28
  • 25
  • 23
  • 21
  • 20
  • 15
  • 15
  • 13
  • 13
  • 11
  • 11
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

[en] AN HYBRID METHOD FOR PHOTOELASTIC ANALYSIS OF ORTHOTROPIC COMPOSITE MATERIALS / [pt] UM MÉTODO HÍBRIDO FOTOELÁSTICO PARA ANÁLISE DE TENSÕES

MARCO ANTONIO MARTINS CAVACO 29 October 2012 (has links)
[pt] Este trabalho apresenta uma nova técnica para análise de tensões em modelos fotoelásticos planos. Essa técnica baseia-se na determinação de coeficientes para funções de tensão aproximadas, através da coleta dos dados extraídos de ordens de franjas isocromáticas e de condições de contorno de modelos fotoelásticos planos. O modelo tem como vantagens a determinação de fatores de concentração de tensões com boa precisão, além de permitir a separação de tensões em pequenas ou grandes regiões de modelos fotoelásticos planos, sem requerer a leitura de franjas isoclínicas. Uma outra grande vantagem está na possibilidade imediata de acoplamento desse método com um analisador de imagens para determinação automática de Kt. Foram encontrados excelentes resultados em problemas onde haviam concentradores de tensão e no estudo de regiões próximas a cargas concentradas. A determinação dos coeficientes das funções foi feita através de um programa escrito em BASIC, que utiliza o método de Newton-Raphson em conjunto com o ajuste dos dados por mínimos quadrados. Vários exemplos foram estudados com o objetivo de avaliar sua performance. Entre eles estão: carga concentrada sobre uma superfície semi-infinita; placa infinita e finita com futo circular sujeita à tração; disco circular submetidos à cargas diametrais compressivas; viga reta carregada à tração constante e a momento constante; e barra com duplo entalhe em U submetida a momento constante. / [en] This work presents a new technique for improving stress analysis in photoelastic plane models. This technique is based on the determination of coefficients of approximated stress functions through the collection of isochromatic fringe data, and by the applications of boundary conditions to photoelastic plane models. The technique has as advantages the accurate determination of stress concentration factors and the stress without the need for collecting isoclinic fringe data. Another great advantage, is the immediate use of this method coupled with an image analyzer device for automatic extraction of Kt. Excellent results were found in problems where stress concentration or concentrated loading were present. The coefficients of the stress functions were determined by a BASIC program, using a Newton-Raphson technique coupled to a least square algorithm. Many example were tested to evaluate its performance. Among them are: concentrated force at a point of a straight boundary; infinite and finite plate with circular holes subjected to uniaxial tensile loads; circular disk under compressive diametral forces; bar subjected to pure tensile and pure bending loads; and a double U-notched bar under pure bending.
52

[en] DETERMINATION OF STRESS INTENSITY FACTORS FOR COMBINED APERTURE MODES I AND II BY PHOTO ELASTICITY / [pt] DETERMINAÇÃO DE FATORES DE INTENSIDADE DE TENSÃO PARA MODOS DE ABERTURA I E II COMBINADOS ATRAVÉS DA FOTOELASTICIDADE

HIROSHI ARAI 21 November 2011 (has links)
[pt] Este trabalho apresenta um método para determinação de fatores de intensidade de tensão, KI e KII, baseado nas técnicas de Newton-Raphson e mínimos quadrados onde o termo Teta 0x, referente ao campo de tensões distante, é tomado como um polinômio completo em x e y para ajustamento do campo de tensões não singular. Um análise do número e da localização dos pontos utilizados na coleta de dados é feita com intuito de melhor poder-se avaliar sua influencia sobre os valores de KI e KII determinados pelo método proposto. Apresenta-se uma comparação entre as distribuições de franjas isocromáticas obtidas experimentalmente e aquelas plotadas com auxílio de um computador utilizando-se para isto os valores determinados de KI e KII e, também, uma comparação entre os resultados obtidos e aqueles existentes na literatura. Finalmente, o método é utilizado na determinação de KI e KII para o problema da existência de trincas nas proximidades de junções soldadas de placas a 90 graus e 45 graus como exemplo de aplicação. / [en] This thesis presents a photoelastic method to determine stress intensy factors, KI and KII, base don the Newton-Raphson and least square techniques, where the term teta 0x refers to the far field stress distribution is substituted by a complete polynomial in x and y for the better adjustment of the nonsingular stress field. Analyses are made of the number and location of points used to obtain the experimental data with the purpose of estudying their influence on the values of KI an KII determined by the proposed method. The experimentally determined isochromatic fringe patterns are compared with computer plotted fringe patterns generated with the aid of the determined values of KI and KII. Finally, the proposed method is employed for the determination of stress intensity factors in problems simulating cracks near joints of welded plates subjected to tension and beding.
53

Influência do tipo de conector na união dente e implantes de hexágono interno e externo: estudo pelo método da fotoelasticidade

Silva, Edmar Ferreira da [UNESP] 04 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-04Bitstream added on 2014-06-13T20:55:06Z : No. of bitstreams: 1 silva_ef_me_araca.pdf: 1411679 bytes, checksum: 3651a9f6c293e68c27d8e79e890167d0 (MD5) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / A união dente-implante ainda gera divergências de opiniões. A proposta deste estudo foi avaliar pelo método da fotoelasticidade a distribuição do stress entre implantes e dentes, nas próteses parciais fixas, comparando conectores rígidos e semi-rígidos e implantes de hexágono interno e externo. Para isto, foram confeccionados dois modelos com resina fotoelástica PL-2, um com implante de hexágono interno (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm) e outro com implante de hexágono externo (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm). Três desenhos de próteses foram fabricados para cada modelo de implante, incorporando cada uma um tipo de conexão para unir implantes e dentes: 1) conexão rígida soldada; 2) conexão semi-rígida; 3) conexão rígida com parafuso oclusal. Os modelos foram colocados no polariscópio e cargas axiais de 100N foram aplicadas em pontos fixos na superfície oclusal das próteses. Os resultados mostraram tendência a uma menor intensidade nas tensões nas conexões semi-rígida e rígida soldada no modelo com implante de hexágono externo e maior intensidade nas tensões na conexão semi-rígida do hexágono interno. Dentro das limitações deste estudo, as seguintes conclusões foram obtidas: houve uma tendência a menor intensidade nas tensões na conexão semi-rígida e na conexão rígida soldada, no modelo com implante de hexágono externo; entre os três tipos de conexões no modelo com implante de hexágono interno, a conexão semi-rígida foi a mais desfavorável; na associação dente-implante é preferível a utilização do implante de hexágono externo. / The union tooth-implant still generate divergences of opinions. The purpose of this study was to examine for the photoelastic metod, the distribution of stress among implants and teeth, in the fixed partial prostheses, comparing rigid and semi-rigid connectors and internal and external hexagon implants. For this, two models were made with photoelastic resin PL-2, one with internal hexagon implant (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm) and other with external hexagon implant (3i - Palm Beach Gardens, Fla. - 4,00 x 13 mm). Three drawings of prostheses were manufactured for each implants model, incorporating each an the connection type to unite implants and teeth: 1) rigid welded connection; 2) semi-rigid connection; 3) rigid connection with screw oclusal. The models were placed in the polariscope and axial loads of 100N were applied in fixed points in the surface oclusal of the prostheses. The results showed tendency to smaller intensity in tensions in the connections semi-rigid and rigid welded in the model with external hexagon implants and larger intensity in the connection semi-rigid of the model internal hexagon implant. The following conclusions were draw: there was tendency the smallest intensity in tensions in the semi-rigid connection and in the rigid welded connection in the model with external hexagon; among the three types of connections in the model with internal hexagon implants the connection semi-rigid was the most unfavorable; in the association tooth-implants it is preferable the use of external hexagon implants.
54

Análise comparativa das tensões e deformações entre próteses implantossuportadas de três elementos com dois ou três pilares /

Nishioka, Gabriela Nogueira de Melo. January 2016 (has links)
Orientador: Guilherme de Siqueira Ferreira Anzalone Saavedra / Banca: Alberto Noriyuki Kojima / Banca: José Scarso Filho / Resumo: O objetivo deste estudo foi avaliar as tensões e deformações in vitro, por meio da fotoelasticidade e da extensometria, em próteses parciais fixas implantossuportadas de três elementos variando o número de pilares: dois e três. O primeiro bloco de poliuretano (modelo mestre 1) recebeu três implantes e o segundo (modelo mestre 2) recebeu dois implantes, todos de hexágono externo. Em seguida, os modelos mestre foram duplicados em resina fotoelástica. Pilares protéticos microunit foram conectados aos implantes com torque de 20 Ncm. Sobre os pilares protéticos dos modelos mestre foram parafusados cilindros plásticos, que receberam estruturas em padrões de resinas, os quais foram fundidos em liga de Ni-Cr (n=10). Quatro extensômetros foram colados na superfície de cada bloco de poliuretano, tangenciando os implantes. Nos modelos mestre e nos modelos fotoelásticos, cada estrutura metálica foi parafusada sobre os pilares protéticos com torque de 10 Ncm. Os dados obtidos na extensometria foram submetidos aos testes estatísticos RM ANOVA e Tukey (5%). As franjas isocromáticas obtidas nos modelos fotoelásticos após cada condição de carga foram registradas com uma câmera digital, visualizadas em um programa de computador e comparadas qualitativamente. Resultados: Houve uma diferença estatística significante entre a quantidade de suporte de uma prótese fixa (p=0,001). Os resultados revelaram que três implantes apresentaram uma melhor distribuição das cargas em qualquer ponto analisado e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study used photoelastic and strain gauge analysis to compare stress and microstrain to perform an in vitro evaluation of the effect of the numbers of support in a implant-supported fixed partial prostheses with tree elements. The first polyurethane block (master model 1) will contain three implants and the second block (model 2) two of them, all implants have a external hexagon. Then, the master models were duplicated in photoelastic resin. Microunit abutments were connected to the implants and received a 20 Ncm torque. Over the master model plastic prosthetic cylinders were screwed the abutments that received standard patterns cast in Ni-Cr alloy (n=10). Four strain gauges (SG) were bonded in the surface of the block, tangentially to the lateral implants. On the master model and photoelastic model, each metallic structure were screwed onto the abutments with a 10 Ncm torque. The data obtained from the strain gauge were analyzed statistically by RM ANOVA and Tukey's test, with a 5% conventional level of significance. The isochromatic fringes obtained in the photoelastic models after each load condition were recorded with a digital camera, visualized with software to facilitate qualitative analysis. Results: There was statistically significant differences in support of FPD( p=0,001).The results demonstrated that 3 implants has higher stress distribution and in the pontic of FPD we found higher stress (2326,95µε in 2 implants and 1006,57µε in 3 implants).In photoelastic images, 3 implants presented better stress distribution than 2 implants. Conclusions: Both methods found similar results. This study suggests ....(Resumo completo, clicar acesso eletrônico abaixo) / Mestre
55

Efeito da geometria e da rigidez do projeto da prótese de quadril no estímulo ao remodelamento ósseo / Effect of geometry and stiffness of hip prosthesis design over stimulus for the bone remodelling

Antonialli, Armando ítalo Sette 16 December 2013 (has links)
Made available in DSpace on 2016-06-02T19:10:19Z (GMT). No. of bitstreams: 1 5667.pdf: 13990597 bytes, checksum: b95cfd98b18d138da54ab95fa27e9034 (MD5) Previous issue date: 2013-12-16 / Universidade Federal de Sao Carlos / The stress shielding phenomenon, resulting from the large difference between materials usually employed in prosthesis and the femur Young modulus, promotes significant bone mineral density loss, which originates several complications after hip arthroplasty. In this work, cervical-diaphisary angle and stem length influence over the mechanical stimulus for the bone remodelling, besides the effect of the low modulus alloy adoption, were evaluated by numerical simulation using the finite element method. In order to validate the computational model, a circular polariscope bending test was proposed, aming to photoelastic stress analysis. Results obtained on numerical simulation and on tests with optical monitoring seem to be both well enough confluent. It can be said that stem length reduction caused considerable increase in load transfer to femur, while cervical-diaphisary angle reduction did not produce so relevant effect. The employment of a low modulus stem, on the other side, really provided the elevation of load transfer to femur on higher levels than it has been achieved by the redesign of prosthesis geometrical features. It is understood that the combination of numerical simulation and photoelastic stress analysis may clearly contribute on an improvement of hip prosthesis design and registration process at ANVISA. / O fenômeno stress shielding, decorrente da grande diferença entre o módulo de elasticidade dos materiais comumente empregados em próteses e o módulo de elasticidade do fêmur, promove uma perda significativa de densidade mineral óssea, a qual origina diversas complicações após uma artroplastia de quadril. Neste trabalho, a influência do ângulo colodiafisário e do comprimento da haste femoral sobre o estímulo mecânico ao remodelamento ósseo, assim como o efeito da adoção de um material de módulo de elasticidade reduzido, foram avaliados por meio de simulação númérica, utilizando o método dos elementos finitos. Visando validar o modelo computacional, foi proposto um ensaio de flexão em polariscópio circular, direcionado à análise fotoelástica de tensões. Os resultados obtidos nas simulações numéricas e nos ensaios sob monitoramento óptico mostraram-se satisfatoriamente confluentes. Pode-se dizer que a redução do comprimento da haste ocasionou um aumento bastante considerável na transferência de carga ao fêmur, ao passo que a diminuição do ângulo colodiafisário não produziu efeito tão relevante. O emprego de uma haste com módulo de elasticidade reduzido, por sua vez, proporcionou a elevação da transferência de carga ao fêmur em níveis muito superiores ao que pode ser obtido pelo reprojeto das variáveis geométricas da prótese. Entende-se que o emprego de simulação numérica combinada com a análise fotoelástica de tensões pode efetivamente contribuir com o aprimoramento do projeto e do processo de registro das próteses de quadril junto à ANVISA.
56

Análise numérica e experimental de juntas aeronáuticas rebitadas sob solicitação estática. / Numerical and experimental analysis of aeronautical riveted joints under static load.

André Ferrara Carunchio 22 May 2015 (has links)
Uniões por prendedores são elementos amplamente utilizados na indústria aeronáutica para a união de partes constituintes da aeronave. Contudo, devido à sua geometria e aos carregamentos sofridos, estes elementos estão frequentemente sujeitos a falhas por fadiga. Assim, para um projeto e dimensionamento bem executado dessas juntas, é necessário conhecer seu comportamento mecânico e o campo de tensões ao qual estão sujeitas. O método dos elementos finitos certamente atende a estas necessidades; porém, o uso de elementos sólidos tridimensionais para a representação destas uniões pode levar a análises demasiadamente demoradas e custosas, sendo desejável o uso de modelos mais simplificados. Nesse trabalho, juntas de topo assimétricas são modeladas pelo método dos elementos finitos, utilizando tanto elementos sólidos tridimensionais quanto elementos de casca, com o objetivo de encontrar um modelo relativamente simples que apresente resultados satisfatórios e requeira um menor tempo de solução. Os resultados numéricos obtidos são comparados com resultados experimentais, que utilizam extensômetros e fotoelasticidade. / Riveted joints are structural elements widely used in the aeronautic industry to connect different parts of the aircraft. However, due to their geometry and working load, they are frequently subjected to fatigue failure. Therefore, to a well executed project of this type of joint, it is necessary to understand the mechanical behavior and the stress field to which they are subjected. The finite element method can certainly answer those needs; however, the use of tridimensional elements to represent this type of joint can lead to time consuming and expensive analysis, being desirable the use of simpler models. In this work, asymmetric butt joints are modeled using the finite element method using both, tridimensional and shell elements, with the objective of finding a model that provides satisfactory results at smaller solution time. The numerical results obtained are compared with experimental results using strain gage and photoelastic procedures.
57

Analise fotoelastica da influencia de intermediarios proteticos na distribuição de tensões induzidas por infra-estruturas implanto-suportadas submetidas a soldagem a laser / Photoelastic stress analysis of abutments influence on stress distribution induced by implant-supported frameworks submitted to laser welding

Damaceno, Alessandra Regina Derogis 29 November 2007 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T22:47:57Z (GMT). No. of bitstreams: 1 Damaceno_AlessandraReginaDerogis_D.pdf: 2207812 bytes, checksum: bee72ab72dd5b1ab3d0126a21f181256 (MD5) Previous issue date: 2007 / Resumo: Este estudo avaliou comparativamente a influência de diferentes intermediários protéticos na indução de tensões em infra-estruturas implanto-suportadas soldadas a laser através da análise fotoelástica. Para isso, foram confeccionadas três infra-estruturas metálicas em monobloco, fundidas em titânio, sobre uma matriz metálica com forma e dimensões similares ao arco mandibular, sendo: 1- infra-estrutura confeccionada com pilares Ucla; 2- infra-estrutura confeccionada sobre pilares Esteticone e 3- infra-estrutura confeccionada sobre pilares Microunit. Após avaliação da interface de adaptação em microscopia óptica e análise de passividade em polariscópio circular, as peças foram seccionadas e submetidas à soldagem vertical a laser. As peças foram novamente avaliadas em relação à adaptação e posteriormente submetidas à análise fotoelástica para comparação do padrão de tensões. Os resultados mostraram a eficiência da soldagem a laser na redução de tensões induzidas pelas infra-estruturas. O método ainda permitiu formação de diferentes padrões de comportamento para os diferentes pilares. Os maiores valores de ordem de franja foram encontrados para a infra-estrutura confeccionada sobre pilares Ucla, seguida daquela sobre pilares Esteticone e por último daquela sobre pilares Microunit. No entanto, a distribuição de tensões ao redor dos implantes foi mais homogênea quando os pilares Esteticone e Microunit foram utilizados. Os valores de desadaptação vertical após soldagem laser encontrados para os diferentes pilares foram de 147.9µm, 389µm e 179.4µm respectivamente para os pilares Ucla, Esteticone e Microunit. Concluiu-se que a técnica de soldagem a laser de infra-estruturas implanto-suportadas reduz significativamente a indução de tensões aos implantes, e que a utilização de pilares intermediários, apesar de permitir maior desajuste marginal das peças, distribui melhor o padrão de formação destas tensões geradas ao redor dos mesmos, com maiores (Esteticone) ou menores (Microunit) valores de ordem de franja / Abstract: This study evaluated the influence of different abutments on stress formation by implant-supported frameworks submitted to laser welding through photoelastic analysis. Three titanium frameworks were cast in-one-piece in a metallic master cast with shape and dimension of mandibular arch: I ¿framework fabricated with Ucla abutments, II ¿framework fabricated over Esteticone abutment and III- framework cast over Microunit abutment. After fit optical microscopy evaluation and non passive analysis in circular polariscopy, the frameworks were sectioned and submitted to vertical laser welded to posterior optical and stress formations analysis to compares the abutments tested. Results showed the laser weld efficiency in the implanted-supported framework stress reduction although had allowed different stress formation patterns among the abutments. The higher franje order number was attributed to the framework cast with Ucla abutments, followed by that cast over Esteticone and Microunit abutments respectively. However the distribution of stress pattern around implants was better with esteticone and microunit abutments utilization. After laser welding the vertical marginal fit found were 147.9µm, 389µm and 179.4µm to Ucla, Esteticone and Microunit abutments, respectively. This study concluded that the laser welding technique reduced significantly the stress formation in the implanted-supported frameworks and although the use of abutments increase the marginal fit of frameworks it allowed the better stress pattern distribution around the implants with higher (Esteticone) and lower (Microunit) franje order number values. Keywords: fixed implant prosthesis, passivity, photoelastic analysis / Doutorado / Protese Dental / Doutor em Clínica Odontológica
58

Aplicação da técnica da fotoelasticidade na análise de fundações por estacas helicoidais / Aplication of the photoelastic method to the analysis of helical screw pile foundations

José Antonio Schiavon 23 July 2010 (has links)
A técnica da fotoelasticidade pode ser particularmente útil na análise de tensões em sistemas com geometrias complexas. Em um equipamento chamado polariscópio, um feixe de luz polarizada atravessa o modelo fotoelástico que representa o protótipo. Ao submeter este modelo a um carregamento, faixas de diferentes cores poderão ser visualizadas. Cada cor é associada a um nível de tensão. As tensões observadas no modelo fotoelástico podem ser comparadas com as tensões determinadas nos modelos numéricos ou analíticos. Em casos específicos, o problema da distribuição de tensões em uma fundação pode ser analisado com emprego da fotoelasticidade. A análise do comportamento de estacas helicoidais através da técnica da fotoelasticidade pode ser então de grande valia para estudos mais aprofundados deste sistema. O principal objetivo desta pesquisa foi viabilizar este método experimental para ser aplicado no Departamento de Geotecnia da EESC em análises de tensões em sistemas geotécnicos. Para validar as análises experimentais, tensões observadas em modelos de geometria simples foram comparadas com as tensões determinadas por meio de modelagem numérica com o método dos elementos finitos. O comportamento da fundação por estaca helicoidal observado pela técnica da fotoelasticidade mostrou semelhança ao observado na modelagem numérica. Por meio da distribuição de tensões, foi possível avaliar a influência da geometria helicoidal da lâmina e da profundidade de instalação da ancoragem no terreno. / The photoelastic method can be particularly useful for stress analysis with complex geometry systems. In equipment called polariscope, a polarized light beam crosses the photoelastic model that represents the prototype. Submitting this model to a load, fringes of different colors can be visualized. Each color is associated to a stress level. The stresses corresponding to the observed fringes on the photoelastic model can be compared to the stresses obtained through analytical or numerical models. In specific cases, the stress distribution problem can be analyzed with the use of photoelasticity. The photoelastic analysis of the helical pile behavior can then be valuable for further studies of this system. The main objective of this research was enabling this experimental method to be applied in the Department of Geotechnical Engineering of EESC in geotechnical systems stress analysis. To validate the experimental analysis, stresses observed in simple geometry models have been compared to those stresses determined by numerical modeling with the finite element method. The observed behavior of the helical pile foundation by photoelastic method showed similarity to that one observed through numerical modeling. Stress distribution analyses allowed evaluating the influence of helical blade geometry and the depth of installation.
59

Análise fotoelástica de distribuição de tensões em implantes paralelos e em protocolo tipo all-on-four / Photoelastic analysis of stress distribution in parallel implants and protocol all-on-four

Zacarias Filho, Rachid Pinto 17 August 2018 (has links)
Orientador: Mauro Antônio de Arruda Nóbilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T12:35:45Z (GMT). No. of bitstreams: 1 ZacariasFilho_RachidPinto_M.pdf: 3525548 bytes, checksum: ebb8dd31a42ac34d09f7027bc5fe19c4 (MD5) Previous issue date: 2010 / Resumo: O objetivo nesta pesquisa foi avaliar in vitro através da fotoelasticidade, as tensões induzidas em protocolos com implantes inclinados (conceito All-on-Four) e paralelos, utilizados em prótese sobre implantes mandibulares com infraestruturas confeccionadas em titânio, soldadas a laser e submetidos à carga distal. Os protocolos foram confeccionados com barras de titânio com 3 mm de diâmetro (Conexão Sistemas de Prótese - SP) soldados sobre 2 modelos-mestres em gesso especial (Durone-Dentsply) sendo: 1 modelo com quatro implantes dispostos de forma paralela (GP) e 1 modelo com quatro implantes, sendo dois mesiais dispostos de forma paralela e dois distais inclinados, instalados segundo o protocolo All-on-four (GI). A disposição dos implantes em número de quatro (GP) possuem perfurações eqüidistantes e paralelas entre si, seguindo a média do espaço intra-foramidal de acordo com o posicionamento encontrado para o sistema Branemark®. No caso do grupo inclinado (GI), a instalação dos quatro implantes foi feita segundo o guia All-on-four da Nobel Biocare®. Todos os implantes Master Screw (Conexão Sistemas de Prótese - SP) eram hexágonos externos e diâmetro regular (3,75mm X 13 mm). Foi confeccionado um modelo com três paredes planas, em resina fotoelástica (Araldite - Araltec) de cada um dos protocolos, permitindo a quantificação das tensões em cada implante, por meio da técnica fotoelástica de transmissão plana. Após carga de 100 Ncm sobre área de cantilever das infra-estruturas, as tensões foram registradas e analisadas em polariscópio circular acoplado a uma máquina fotográfica digital (Cyber-Shot DSC-717 - Sony) que captou as imagens. Os resultados evidenciaram que a infraestrutura do GI apresentou maior número de franjas especialmente sobre os implantes inclinados distais. O grupo com implantes paralelos demonstrou melhor distribuição das tensões após a aplicação do carregamento distal / Abstract: The aim of this study was to evaluate in vitro by photoelasticity, the stresses induced in inclined implant protocols (All-on-Four) and parallel, used in mandibular implant prosthesis with infrastructure made of titanium, laser welded and subjected distal load. The protocols were made of titanium bars with 3mm diameter (Conexao Sistemas de Protese - SP) soldiers on two models-masters in special gypsum (Dentsply-Durone) where: a model with four implants arranged in parallel (GP) and a model with four implants, two of them arranged in parallel mesial and two distal inclined, constructed according to the protocol All-on-four (GI). The provision of implants in number four (GP) have holes equidistant and parallel to each other, according to the average of the intra-foramidal according to the position found for the Branemark system ®. In the case of tilted group (IG), the installation of the four implants was made according to the guide All-on-four Nobel Biocare ®. All implants Master Screw (Conexao Sistemas de Protese - SP) were regular hexagons and external diameter (3.75 mm X 13 mm). A model was built with three flat walls in photoelastic resin (Araldite - Araltec) from each of the protocols, allowing the quantification of stress in each implant by means of technical transmission photoelastic flat. After loading about 100 Ncm cantilever area of infrastructure, the tensions were recorded and analyzed in a circular polariscope coupled to a digital camera (Cyber-Shot DSC-717 - Sony) that captured the images. The results showed that the infrastructure of GI presented more especially on the fringes inclined distal implants. The group with parallel implants showed better stress distribution after the application of distal loading / Mestrado / Protese Dental / Mestre em Clínica Odontológica
60

Aplicação de técnica óptica no estudo da distribuição de tensões em modelos reduzidos de feixe de toras e peças serradas / Use of optical techniques applied on stress distribution study of reduced bundle log models and sawn pieces

Gazzola, Jonathan, 1981- 18 August 2018 (has links)
Orientadores: Inácio Maria Dal Fabbro, Julio Soriano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-18T01:26:15Z (GMT). No. of bitstreams: 1 Gazzola_Jonathan_M.pdf: 6105660 bytes, checksum: f01d4a2bd88ae142584872066c1b7532 (MD5) Previous issue date: 2011 / Resumo: A silvicultura ocupa a segunda posição no agronegócio brasileiro, exibindo grande importância econômica e social para o país. As atividades econômicas associadas ao reflorestamento enfrentam diversos obstáculos internos e externos, os quais se contrapõem ao crescimento desse setor no país. Nesse sentido, o transporte de madeira se torna um fator de grande concentração de custo. Toras de madeira, quando atuam em conjunto em forma de feixes apresentam maior rigidez a esforços do que atuando individualmente. As técnicas fotoelásticas podem determinar tensões e deformações em objetos independente da complexidade de sua geometria. A técnica óptica de moiré é considerada como uma técnica fotoelástica viável e de resultados confiáveis. A proposta deste trabalho foi de aplicar a técnica de moiré de sombra na determinação qualitativa e quantitativa da distribuição de tensões em modelos reduzidos de feixe de toras, doravante denominados MRFT. Foi utilizado neste trabalho de pesquisa, essência da espécie Eucalyptus saligna com corpos de prova divididos em três grupos distintos, de acordo com o diâmetro da tora. Uma simulação computacional, através do programa ABAQUS, foi realizada como forma de comparação dos dados qualitativos com o ensaio fotoelástico. Dados experimentais de tensão, obtidos pelos dados fornecidos por sensores acoplados à prensa eletrônica, foram comparados com os resultados de quantificação de tensão obtida pelo método de moiré de sombra. A comparação entre os resultados experimentais do ensaio de carregamento, bem como a simulação computacional associada ao comportamento para vigas atuantes em feixes determinado pela teoria da mecânica dos materiais indicou que a técnica de moiré de sombra foi adequada para a determinação de distribuição de tensão no MRFT. Os resultados mostraram inicialmente a possibilidade do uso do feixe de madeiras para otimização de forwarder. É concluído pelos resultados de qualificação da distribuição de tensão que os elementos que compunham o MRFT atuaram de forma unida. A análise dos resultados quantitativos mostra que, dadas as imperfeições nas superfícies que podem implicar em não efetividade do contato entre as toras, conclui-se que, as toras atuaram individualmente. Também é concluído que a técnica óptica de moiré é adequada para se determinar a distribuição de tensão em peça fletidas / Abstract: The silviculture figures as the second most important Brazilian agribusiness activity, exhibiting economical and social importance. Economical activities associated to reforestation face several internal and external obstacles which contrast with the development in this economical sector. Analyzing the costs related to wood exploration chain, the transportation figures the highest concentration. Wood logs, acting united as bundle logs, become more resistant to loading when compared with individual elements. Photoelastic techniques are able to determine stress and strain distribution on loaded specimens, independently of theirs geometrical shapes. Moiré optical techniques are considered as capable and reliable photoelastic techniques. This research work objectives the application of shadow moiré technique to qualitative and quantitative stress distribution determination reduced bundle log models, named as (RBLM). Wood specimens have been made by Eucalyptus saligna specie, and they were classified into three distinct groups, according their log diameter. Computational simulation, using ABAQUS software, has been carried on to compare qualitative results obtained by photoelastic test. Stress experimental dates, obtained through dates provided by electronical pressure machine sensors, have been compared to quantitative results obtained through shadow moiré technique. Comparison between loading test dates, as well as computational simulation associated to the supposed results determined by material mechanics theories to beam working in bundles showed that shadow moiré techniques were adequate to determine stress distribution on RBLM. Results obtained through shadow moiré technique showed a possibility of using bundle logs to forwarder design optimization. It is concluded that the stress distribution qualitative analysis showed individual pieces that composed BLRM worked as united element. Analyzing quantitative results obtained through shadow moiré technique, and considering surface imperfections, which is able to imply a not effective contact among wood logs, is concluded that, quantitatively, the logs acted individually. It is also concluded that shadow moiré optical technique is adequate to determine qualitative and quantitative stress distribution on bent pieces / Mestrado / Maquinas Agricolas / Mestre em Engenharia Agrícola

Page generated in 0.0565 seconds