• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • Tagged with
  • 16
  • 16
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analogues peptidiques marqués au gallium-68 pour l’imagerie TEP des récepteurs membranaires couplés aux protéines G / PET Imaging of G Protein-Coupled Membrane Receptors with 68Ga Radiolabelled Peptide

Prignon, Aurelie 21 December 2017 (has links)
Ces dernières années, le ciblage des RCPG avec des ligands radiomarqués est devenu très important en imagerie nucléaire, notamment avec le remplacement progressif d’analogues peptidiques de la somatostatine marqués à l’111In pour la TEMP par d’autres marqués au 68Ga pour l'imagerie TEP qui présente une meilleure efficacité diagnostique. Les récepteurs de haute affinité de la bombésine (GRPR) ou de la neurotensine (NTR1) sont eux aussi des RCPG surexprimés par les cellules tumorales par rapport au tissu sain. Le GRPR est surexprimé dans 83% des carcinomes mammaires canalaires estrogènes dépendants. Dans la première partie de ce travail, nous avons démontré qu’un agoniste du GRPR, l’AMBA marqué au 68Ga, permettait la détection en TEP d’un modèle murin de cancer du sein humain estrogène-dépendant et qu’il permettait de prédire la réponse tumorale à une hormonothérapie de manière plus sensible que le 18F-FDG.L’équipe du Dr. Gruaz-Guyon a développé de nouveaux radioligands analogues de la neurotensine pour le ciblage des tumeurs exprimant le NTR1 et a étudié les propriétés de ces peptides marqués à l'111In dans un modèle de tumeurs d’adénocarcinome colique surexprimant le NTR1. L’obtention d’images TEMP de contraste élevé, permettant une détection des greffes tumorales dans des temps courts après injection, a conduit cette équipe à envisager ce traceur peptidique pour l’imagerie TEP. Dans la seconde partie de ce travail, nous avons réalisé le radiomarquage au 68Ga du meilleur de ces dérivés (DOTA NT20.3) et évalué son potentiel pour l'imagerie TEP et la détection de tumeurs d’adénocarcinome colique. La surexpression de NTR1 a été démontrée dans plusieurs autres cancers comme l’adénocarcinome pancréatique (PDAC) (75-88%). Nous avons donc voulu étudier l'expression du NTR1 dans une tumorothèque locale de PDAC. Nous avons ensuite démontré le potentiel du 68Ga-DOTA-NT20.3 pour l’imagerie TEP dans deux modèles murins de PDAC humains. Nous avons caractérisé sa biodistribution, évalué sa spécificité in vivo et l’avons comparé au 18F-FDG, notamment pour valider sa capacité à discriminer in vivo la pancréatite de l’adénocarcinome pancréatique. / In recent years, the targeting of G protein-coupled membrane receptors (GPCRs) with radiolabeled ligands has become very important in nuclear imaging, particularly with the progressive replacement of somatostatin analogues labelled with 111In for SPECT by others labelled with 68Ga for PET imaging, which improves diagnostic efficacy. High-affinity bombesin receptors (GRPR) or neurotensin receptors (NTR1) are also GPCRs overexpressed in many cancers as compared with normal tissue. GRPR is overexpressed in 83% of estrogen-dependent ductal carcinomas. In the first part of this work, we demonstrated that 68Ga-AMBA, an agonist ligand of GRPR, allowed the PET detection of a mouse model of estrogen-dependent breast cancer and could be more sensitive than 18F-FDG to predict and monitor tumour response to hormone therapy.Dr. Gruaz-Guyon's team has developed new neurotensin radioanalogues for targeting NTR1-positive tumours. They studied the properties of these 111In-labeled peptides in a model of colon adenocarcinoma overexpressing NTR1. Obtaining high-contrast images allowing the detection of cancer within a short time after injection, this team subsequently developed this peptide radiotracer for PET imaging. In the second part of this work, we carried out the 68Ga radiolabeling of the best-performing of these derivatives and evaluated its potential for PET imaging of colon adenocarcinoma in a tumor model. Overexpression of NTR1 has been demonstrated in several human cancers such as PDAC (75-88%). We characterized the expression of NTR1 using specimens of human pancreatic cancer and then demonstrated the potential of this PET radiotracer to image two mouse models of human PDAC. We characterized its biodistribution, assessed its specificity in vivo in comparison with 18F-FDG, in particular its ability to discriminate in vivo pancreatitis from pancreatic adenocarcinoma.
2

Comparaison de radiotraceurs marqués au gallium-68 et au fluor-18 pour l’imagerie TEP de modèles précliniques de neuroblastome, de glioblastome ou de cancer bronchopulmonaire. / Comparison of gallium-68 and fluor-18 labelled radiotracers for PET imaging of preclinical models of neuroblastoma, glioblastoma or bronchopulmonary cancer.

Provost, Claire 14 March 2018 (has links)
La Tomographie par Emission de Positons (TEP) est une modalité d’imagerie médicale en pleine expansion depuis une quinzaine d’années. En oncologie, la TEP au 18F-fluorodésoxyglucose (FDG) est devenue un outil essentiel pour la prise en charge des patients souffrant de cancer. Cependant il ne permet pas la détection et le suivi de tous les cancers, de nombreux radiotraceurs sont donc développés, plus ciblés et plus spécifiques que les analogues des substrats métaboliques. Durant ce travail de doctorat, la première étude TEP a été réalisée avec du 68Ga-DOTATOC dans un modèle préclinique de neuroblastome (NB) humain. Cette tumeur, qui présente des analogies avec les tumeurs neuroendocrines, exprime fréquemment des récepteurs de type 2 de la somatostatine (SSTR2). Nous avons comparé, le FDG au 68Ga-DOTATOC dans 3 modèles murins de différents NB humains, exprimant les SSTR2 avec une densité différente. La deuxième étude a comparé et évalué le FDG et un 68Ga-RGD, ligand des intégrines, sur des modèles murins de glioblastome (GB) humain surexpriment l’intégrine αvβ3. L’évaluation s’est faite dans le suivi de 4 groupes d’animaux traités ou non avec un anti-angiogénique et/ou une chimiothérapie. La troisième étude a comparé et évalué le 68Ga-RGD et le 18F-RGD-K5 dans un modèle murin, associant GB humain et carcinome pulmonaire humain, lors du suivi d’un traitement anti-angiogénique. Le 68Ga-DOTATOC et le FDG ont tous deux permis de visualiser les 3 différents modèles de NB. La fixation du FDG s’est avérée corrélée à celle du 68Ga-DOTATOC et, ex vivo, à l’expression des SSTR2 et du Ki-67. Le 68Ga-RGD, contrairement au FDG, a permis de discriminer les groupes répondeurs après 6 jours de traitement. Bien que les résultats soient concordants entre le 68Ga-RGD et le 18F-RGD-K5, celui-ci a permis une meilleure visualisation et un meilleur suivi sous traitement des GB. / Positron Emission Tomography (PET), a modality of functional medical imaging, has been developing for about 15 years. In oncology, 18F-fluorodeoxyglucose (FDG) PET has become a main tool for cancer diagnosis. However, FDG cannot detect and monitor all types of cancer. Thus research is continuing, exploring new applications for other documented tracers and developing more specific and targeted tracers than analogues of metabolic substrates. The first study of this doctorate was done with 68Ga-DOTATOC PET in preclinical model of neuroblastoma (NB), which share some biologic properties with neuroendocrine tumours, frequently expressing somatostatin receptors subtype 2 (SSTR2). Our aim was to compare FDG and 68Ga-DOTATOC PET in 3 different mouse models of human NB that express SSTR2 at different levels. The second study compared FDG and 68Ga-RGD, a ligand of integrins, in a mouse model of human glioblastoma (GB) that overexpresses αvβ3 integrin. Both tracers have been evaluated in monitoring 4 groups of animals untreated or treated with an anti-angiogenic agent and/or chemotherapy. The third study compared the 18F-RGD-K5 and 68Ga-RGD in a mouse model bearing human GB and pulmonary carcinoma, which has a low expression of αvβ3 integrin. The potential of those tracers for monitoring an anti-angiogenic treatment was subsequently studied. Both 68Ga-DOTATOC and FDG allowed visualizing the different models of NB. There was a correlation between tumour uptake of FDG and of 68Ga-DOTATOC and, ex vivo, with SSTR2 and Ki-67. 68Ga-RGD, unlike FDG, discriminated responders after 6 days of treatment. Results with 18F-RGD-K5 and 68Ga-RGD were concordant, but 18F-RGD-K5 was more efficient than 68Ga-RGD for visualization and treatment monitoring GB.
3

Estudo de radiomarcação com gálio-68 do inibidor de PSMA baseado em ureia - avaliação comparativa de método automatizado e não automatizado / Study radiolabeling of urea-based PSMA inibitor with 68-gallium comparative evaluation of authomated and not authomated methods

Alcarde, Lais Fernanda 05 April 2016 (has links)
Os métodos para o diagnóstico clínico de câncer de próstata incluem o toque retal e a dosagem do antígeno prostático específico (PSA). Entretanto, o nível de PSA encontra-se elevado em cerca de 20 a 30% dos casos relacionados a patologias benignas, o que resulta em falsos positivos e leva os pacientes a realização de biópsias desnecessárias. O antígeno de membrana prostático específico (PSMA), ao contrário, é sobre expresso no câncer de próstata e encontrado em baixos níveis em órgãos saudáveis. Em razão disso, estimulou-se o desenvolvimento de pequenas moléculas inibidoras do receptor de PSMA, que carreguem agentes de imagem ao tumor e que não sejam prejudicadas pela microvasculatura deste. Estudos recentes sugerem que o quelante HBED-CC contribui intrinsicamente para a ligação do peptídeo inibidor de PSMA baseado em ureia (Glu-ureia-Lys) ao grupo farmacofórico. Este trabalho descreve os estudos de otimização das condições de radiomarcação do PSMA-HBED-CC com 68Ga, utilizando sistema automatizado (módulo de síntese) e método não automatizado, buscando estabelecer uma condição adequada de preparação deste novo radiofármaco, com ênfase no rendimento da marcação e na pureza radioquímica do produto. Também objetivou avaliar a estabilidade do peptídeo radiomarcado em condições de transporte e estudar a distribuição biológica do radiofármaco em camundongos sadios. O estudo dos parâmetros de radiomarcação possibilitou definir um método não automatizado que resultou em alta pureza radioquímica (> 95%), sem a necessidade de purificação do radiomarcado. Já o método de marcação automatizado foi adaptado para utilizar módulo de síntese e software já disponíveis no IPEN, e também resultou em rendimento de síntese elevado (≥ 90%) e superior aos descritos em literatura, com a vantagem associada de maior controle do processo produtivo em atendimento aos requisitos de Boas Práticas de Fabricação. O estudo dos parâmetros de radiomarcação permitiu a obtenção do PSMA-HBED-CC-68Ga com atividade específica superior à utilizada em estudos clínicos publicados (≥ 140,0 GBq/μmol), com estabilidade suficientemente longa, que permitirá o transporte às clínicas para aplicação na obtenção de imagens diagnósticas. Os perfis de biodistribuição e farmacocinético do peptídeo radiomarcado foram compatíveis com os encontrados na literatura. Conclui-se que o PSMA-HBED-CC-68Ga, é uma importante ferramenta de diagnóstico do câncer de próstata por imagem PET, pode ser produzido tanto por método automatizado ou não automatizado, com alta pureza radioquímica, alto rendimento de síntese e estabilidade do radiofármaco. / The methods for clinical diagnosis of prostate cancer include rectal examination and the dosage of the prostatic specific antigen (PSA). However, the PSA level is elevated in about 20 to 30% of cases related to benign pathologies, resulting in false positives and leading patients to unnecessary biopsies. The prostate specific membrane antigen (PSMA), in contrast, is over expressed in prostate cancer and founded at low levels in healthy organs. As a result, it stimulated the development of small molecule inhibitors of PSMA, which carry imaging agents to the tumor and are not affected by their microvasculature. Recent studies suggest that the HBED-CC chelator intrinsically contributes to the binding of the PSMA inhibitor peptide based on urea (Glu-urea-Lys) to the pharmacophore group. This work describes the optimization of radiolabeling conditions of PSMA-HBED-CC with 68Ga, using automated system (synthesis module) and no automated method, seeking to establish an appropriate condition to prepare this new radiopharmaceutical, with emphasis on the labeling yield and radiochemical purity of the product. It also aimed to evaluate the stability of the radiolabeled peptide in transport conditions and study the biological distribution of the radiopharmaceutical in healthy mice. The study of radiolabeling parameters enabled to define a non-automated method which resulted in high radiochemical purity (> 95 %) without the need for purification of the labeled peptide. The automated method has been adapted, using a module of synthesis and software already available at IPEN, and also resulted in high synthetic yield (≥ 90%) specially when compared with those described in the literature, with the associated benefit of greater control of the production process in compliance with Good Manufacturing Practices. The study of radiolabeling parameters afforded the PSMA-HBED-CC-68Ga with higher specific activity than observed in published clinical studies (≥ 140,0 GBq/μmol), with a sufficiently long stability, which will enable transport to clinics for use in diagnostic imaging. Biodistribution and pharmacokinetic profiles of the radiolabeled peptide were consistent with those founded in the literature. We concluded that PSMA-HBED-CC-68Ga, important diagnostic tool for prostate cancer imaging with PET, can be produced by either automated or not automated method with high radiochemical purity, high synthetic yield and stability of the radiopharmaceutical.
4

Évaluation de traceurs peptidiques radiomarqués pour la détection du cancer du sein et de la prostate par imagerie TEP

Fournier, Patrick January 2012 (has links)
Les cancers du sein chez les femmes et de la prostate chez les hommes sont les cancers les plus répandus au Canada. Un diagnostic précoce et un suivi de la thérapie bien adapté au type de cancer représentent des facteurs importants pour le traitement de ces maladies. La tomographie d'émission par positrons (TEP) permet de visualiser la distribution spatiale et temporelle de molécules radiomarquées. Le développement de nouveaux traceurs spécifiques à certains récepteurs surexprimés dans différents types de cancer permettrait d'améliorer le diagnostic à l'aide de l'imagerie TEP. La bombésine se lie à 3 types de récepteurs humains, dont le récepteur à relâche de gastrine (GRPR). Il est surexprimé dans 65% des cas de carcinomes canalaires in situ et 63% des tumeurs prostatiques. Le GRPR pourrait également être utilisé comme marqueur du caractère malin dans ces cas de cancer. Notre hypothèse est que les ligands radiomarqués ciblant le GRPR permettraient un meilleur diagnostic à partir de l'imagerie TEP et contribuerait au développement d'une médecine personnalisée. Le premier objectif de cette étude vise à évaluer les effets du radiométal utilisé pour marquer les molécules sur les propriétés physicochimiques des traceurs ciblant les GRPR. Un peptide modèle, le NOTA-PEG-BBN(6-14), a été marqué au [indice supérieur 64] Cu et au [indice supérieur 68] Ga. Ces études ont démontré que l'isotope utilisé pour le marquage influence l'affinité du peptide pour le GRPR et conséquemment son accumulation spécifique. Le deuxième objectif consiste à évaluer et comparer différents monomères et homodimères dérivés de la bombésine afin d'étudier le rôle de la valence du ligand sur la captation et la rétention tumorale ainsi que d'évaluer l'effet de la longueur de l'espaceur entre les deux ligands des homodimères de la bombésine sur la captation/rétention tumorale. Ainsi, le NOTA-PEGBBN(6-14) et deux homodimères ont été comparés in vitro et in vivo . Les composés homodimériques présentent une accumulation non-spécifique accrue au niveau des poumons, de la rate, du foie et des reins. De plus, le NOTA-dimère 2 possédant un plus long espaceur présente une accumulation spécifique augmentée au niveau du pancréas, un organe riche en GRPR, et une rétention supérieure au niveau des cellules tumorales prostatiques PC3 tant in vitro qu' in vivo chez les souris Balb/c nues xénogreffées.
5

Desenvolvimento de métodos de purificação do sup(67)Ge e sup(68)Ge para a marcação de biomoléculas / Development of methods for the purification of sup(67)Ge e sup(68)Ge for biomolecules labeling

COSTA, RENATA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:14Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
6

Desenvolvimento de métodos de purificação do sup(67)Ge e sup(68)Ge para a marcação de biomoléculas / Development of methods for the purification of sup(67)Ge e sup(68)Ge for biomolecules labeling

COSTA, RENATA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:14Z (GMT). No. of bitstreams: 0 / Há mais de 50 anos os geradores de 68Ge/68Ga vêm sendo desenvolvidos, obtendo o 68Ga sem a necessidade da instalação de um cíclotron próximo à radiofarmácia ou ao centro hospitalar que tenha um PET/CT. O 68Ga é um emissor de pósitron com baixa emissão de fóton (β+, 89%, 1077 keV) e meia vida de 67,7 minutos, compatível com a farmacocinética de moléculas de baixo peso molecular, como peptídeos e fragmentos de anticorpos. Além disso, a química do Ga permite a ligação estável com agentes quelantes acoplados com peptídeos, como o DOTA. Todas estas características do 68Ga aliado a tecnologia PET/CT permitiram avanços em imagem molecular, como no diagnóstico de doenças de origem neuroendócrina. Entretanto, o eluato de 68Ga proveniente dos geradores de 68Ge/68Ga comerciais, ainda contém altos níveis de contaminantes, como o 68Ge e outros metais que competem quimicamente com o 68Ga, como o Fe3+ e Zn2+ e, como consequência, há redução do rendimento de marcação com biomoléculas. Quanto menor a quantidade de impurezas no eluato, a competição entre o peptídeo radiomarcado e peptídeo não marcado será menor e a qualidade de imagem será melhor, por isso existe a necessidade de diminuir a quantidade destes metais. Portanto, os objetivos deste trabalho são avaliar os métodos de purificação do 68Ga para a marcação de biomoléculas, com ênfase no estudo das impurezas químicas presentes nos radioisótopos primários, e desenvolver um método de purificação inédito. Diversos métodos de purificação foram estudados. Na purificação em resina catiônica tradicional e comercial, em que o 68Ga é adsorvido em resina catiônica e eluído em uma solução de acetona/ácido, a resina utilizada não é disponível comercialmente. Várias resinas catiônicas foram testadas simulando o processo comercial, e o uso das menores partículas da resina catiônica AG50W-X4 (200-400 mesh) foi a que apresentou os melhores resultados. Um método inovador foi a cromatografia por extração, onde o éter diisopropílico é adsorvido em resina XAD 16 e o 68Ga eluído em água deionizada. Apesar dos resultados de recuperação do 68Ga e a separação entre o 68Ga e o 65Zn terem sido bons, não houve reprodutibilidade na purificação dos metais. O método mais promissor e inédito foi a purificação do 68Ga em resina catiônica em meio básico que apresentou bons resultados, principalmente em relação à redução do Zn (98 ± 2)%, o contaminante químico encontrado em maior abundância no eluato de 68Ga. A redução total de impurezas foi (95 ± 4)%. Os peptídeos DOTATOC/DOTATATO foram marcados com o 68Ga em três diferentes formas: purificado em meio básico, por extração por solventes e sem a purificação prévia, o melhor resultado de rendimento de marcação do 68Ga DOTATATO foi obtido após a purificação do 68Ga em meio básico, comprovando a eficiência do processo. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
7

Estudo de radiomarcação com gálio-68 do inibidor de PSMA baseado em ureia - avaliação comparativa de método automatizado e não automatizado / Study radiolabeling of urea-based PSMA inibitor with 68-gallium comparative evaluation of authomated and not authomated methods

Lais Fernanda Alcarde 05 April 2016 (has links)
Os métodos para o diagnóstico clínico de câncer de próstata incluem o toque retal e a dosagem do antígeno prostático específico (PSA). Entretanto, o nível de PSA encontra-se elevado em cerca de 20 a 30% dos casos relacionados a patologias benignas, o que resulta em falsos positivos e leva os pacientes a realização de biópsias desnecessárias. O antígeno de membrana prostático específico (PSMA), ao contrário, é sobre expresso no câncer de próstata e encontrado em baixos níveis em órgãos saudáveis. Em razão disso, estimulou-se o desenvolvimento de pequenas moléculas inibidoras do receptor de PSMA, que carreguem agentes de imagem ao tumor e que não sejam prejudicadas pela microvasculatura deste. Estudos recentes sugerem que o quelante HBED-CC contribui intrinsicamente para a ligação do peptídeo inibidor de PSMA baseado em ureia (Glu-ureia-Lys) ao grupo farmacofórico. Este trabalho descreve os estudos de otimização das condições de radiomarcação do PSMA-HBED-CC com 68Ga, utilizando sistema automatizado (módulo de síntese) e método não automatizado, buscando estabelecer uma condição adequada de preparação deste novo radiofármaco, com ênfase no rendimento da marcação e na pureza radioquímica do produto. Também objetivou avaliar a estabilidade do peptídeo radiomarcado em condições de transporte e estudar a distribuição biológica do radiofármaco em camundongos sadios. O estudo dos parâmetros de radiomarcação possibilitou definir um método não automatizado que resultou em alta pureza radioquímica (> 95%), sem a necessidade de purificação do radiomarcado. Já o método de marcação automatizado foi adaptado para utilizar módulo de síntese e software já disponíveis no IPEN, e também resultou em rendimento de síntese elevado (≥ 90%) e superior aos descritos em literatura, com a vantagem associada de maior controle do processo produtivo em atendimento aos requisitos de Boas Práticas de Fabricação. O estudo dos parâmetros de radiomarcação permitiu a obtenção do PSMA-HBED-CC-68Ga com atividade específica superior à utilizada em estudos clínicos publicados (≥ 140,0 GBq/μmol), com estabilidade suficientemente longa, que permitirá o transporte às clínicas para aplicação na obtenção de imagens diagnósticas. Os perfis de biodistribuição e farmacocinético do peptídeo radiomarcado foram compatíveis com os encontrados na literatura. Conclui-se que o PSMA-HBED-CC-68Ga, é uma importante ferramenta de diagnóstico do câncer de próstata por imagem PET, pode ser produzido tanto por método automatizado ou não automatizado, com alta pureza radioquímica, alto rendimento de síntese e estabilidade do radiofármaco. / The methods for clinical diagnosis of prostate cancer include rectal examination and the dosage of the prostatic specific antigen (PSA). However, the PSA level is elevated in about 20 to 30% of cases related to benign pathologies, resulting in false positives and leading patients to unnecessary biopsies. The prostate specific membrane antigen (PSMA), in contrast, is over expressed in prostate cancer and founded at low levels in healthy organs. As a result, it stimulated the development of small molecule inhibitors of PSMA, which carry imaging agents to the tumor and are not affected by their microvasculature. Recent studies suggest that the HBED-CC chelator intrinsically contributes to the binding of the PSMA inhibitor peptide based on urea (Glu-urea-Lys) to the pharmacophore group. This work describes the optimization of radiolabeling conditions of PSMA-HBED-CC with 68Ga, using automated system (synthesis module) and no automated method, seeking to establish an appropriate condition to prepare this new radiopharmaceutical, with emphasis on the labeling yield and radiochemical purity of the product. It also aimed to evaluate the stability of the radiolabeled peptide in transport conditions and study the biological distribution of the radiopharmaceutical in healthy mice. The study of radiolabeling parameters enabled to define a non-automated method which resulted in high radiochemical purity (> 95 %) without the need for purification of the labeled peptide. The automated method has been adapted, using a module of synthesis and software already available at IPEN, and also resulted in high synthetic yield (≥ 90%) specially when compared with those described in the literature, with the associated benefit of greater control of the production process in compliance with Good Manufacturing Practices. The study of radiolabeling parameters afforded the PSMA-HBED-CC-68Ga with higher specific activity than observed in published clinical studies (≥ 140,0 GBq/μmol), with a sufficiently long stability, which will enable transport to clinics for use in diagnostic imaging. Biodistribution and pharmacokinetic profiles of the radiolabeled peptide were consistent with those founded in the literature. We concluded that PSMA-HBED-CC-68Ga, important diagnostic tool for prostate cancer imaging with PET, can be produced by either automated or not automated method with high radiochemical purity, high synthetic yield and stability of the radiopharmaceutical.
8

Le gallium : applications en vue d'une utilisation en imagerie moléculaire / Gallium : applications for molecular imaging

Ben Azzouna, Rana 12 December 2016 (has links)
La tomographie par émission de positons (TEP) est une technique d’imagerie moléculaire avec de meilleures performances que la tomographie par émission monophotonique. Son utilisation contribue à l’amélioration des prises en charge des patients. Dans les centres dépourvus de cyclotrons, le 68Ga disponible à partir d’un générateur constitue une alternative pour le développement de traceurs TEP. Pour pouvoir développer des 68Ga-traceurs, un travail de caractérisation de la qualité des éluats a été effectué. Des méthodes de marquage adaptées ont été mises en place et validées. Nous nous sommes intéressés à trois cibles moléculaires particulièrement intéressantes dans les pathologies cardiovasculaires: les récepteurs de la somatostatine (SSTR) surexprimés dans les tumeurs neuroendocrines (TNE) mais constituant aussi une cible d’intérêt dans les pathologies cardiovasculaires à composante inflammatoire ; la phosphatidylsérine (PS), un marqueur de l’apoptose cellulaire et de l’activation plaquettaire ; la P-sélectine, un marqueur des activations plaquettaire et endothéliale. Les traceurs suivants ont été développés: 1) Analogues de la somatostatine ciblant les SSTR: a)68Ga-DOTANOC validé pour l’imagerie des TNE-Gastroentéropancréatiques dans le cadre d’un essai clinique multicentrique. b) 68Ga-NODAGANOC testé in vitro sur des cellules d’adénocarcinome pancréatique. Cette validation initiale dans l’application la plus fréquente(oncologie) a pour objectif de faciliter le passage vers des applications cardiovasculaires futures (athérosclérose, myocardite...) ; 2) Un peptide ciblant la PS : le 68Ga-P04087 ; 3) Un polysaccharide ciblant la P-sélectine: 68Ga-NODAGA-Asphy. Les deux derniers traceurs ont été testés sur un modèle d’endocardite infectieuse chez le rat. / The Positron emission tomography (PET) is a molecular imaging technique with usually better performances than Single-Photon Emission Computed Tomography. Consequently, the use of PET and appropriate tracers could enable clinicians to make a better therapeutic decision, thus improving the management of patients. In centers without cyclotrons, 68Ga available from a generator is an alternative for the development of PET tracers. In order to develop 68Ga labeled-molecules, a characterization of the quality of the eluates was performed. Radiolabeling techniques adapted to the quality of the starting material were developed and validated. In this thesis we focused on three particularly interesting molecular targets in cardiovascular pathologies: somatostatin receptors (SSTR), overexpressed in neuroendocrine tumors (NETs) but also constituting a target of interest in cardiovascular diseases with an inflammatory component; phosphatidylserine (PS), a marker of cell apoptosis and platelet activation; P-selectin, a marker of platelet and endothelial activation.The following tracers have been developed: 1) Somatostatin analogues which target SSTR: a) 68Ga-DOTANOC validated for Gastroenteropancreatic-NETs imaging and used in a multicenter clinical trial. b) 68Ga-NODAGANOC tested in vitro on pancreatic adenocarcinoma cells. This initial validation in the most common application (oncology) aims to facilitate the transition to future cardiovascular applications (atherosclerosis, myocarditis ...) 2) A peptide for PS targeting: 68Ga-P04087; 3) A polysaccharide for P-selectin targeting: 68Ga-NODAGA-Asphy. The last two radiolabeled molecules were tested in a rat model of infective endocarditis.
9

Synthèse de traceurs bimodaux utilisables en imagerie médicale TEP/IRM / Bimodal tracers synthesis for medical imaging PET/MRI

Kennel, Sybille 26 October 2015 (has links)
Aujourd’hui les médecins disposent de nombreuses techniques d’imagerie médicale afin d’établir des diagnostics précis et précoces. Cependant, chacune de ces techniques possède ses propres avantages et inconvénients. C’est pourquoi, l’utilisation de méthodes bi- ou multi-modales paraît intéressante. Parmi celles-ci, la combinaison TEP/IRM permet d’apporter des informations complémentaires. Il est alors nécessaire d’injecter aux patients un traceur adapté à chacune de ces modalités. Ce travail de thèse a donc consisté à synthétiser des plateformes moléculaires « universelles » utilisables pour l’imagerie IRM et TEP selon deux stratégies. La première a consisté en la synthèse d’une molécule composée d’un macrocycle de type DO3A permettant à la fois la chélation d’un atome de gadolinium pour l’IRM mais aussi d’un atome de gallium 68 pour la TEP. L’idée étant, afin d’avoir une sonde bimodale, de réaliser un mélange des deux composés. La seconde stratégie a été de synthétiser une unique molécule pouvant être marquée à la fois par du gadolinium pour l’IRM et par un atome de fluor 18 pour la TEP. Afin de pouvoir cibler un phénomène physiopathologique donné, l’idée de ces plateformes est de pouvoir introduire de manière simple et versatile une biomolécule. La chimie « click » semble être une méthode particulièrement attractive pour pouvoir réaliser cet objectif. Cependant, cette réaction, habituellement catalysée au cuivre est difficilement applicable sur ce genre de plateforme du fait de l’affinité du cuivre pour le macrocycle DO3A. Ce problème a donc été contourné par utilisation de la réaction de chimie « click » catalysée par des complexes de ruthénium afin d’avoir accès aux deux plateformes macrocycliques. / Today physicians can use a wide variety of medical imaging techniques to establish early and accurate diagnosis. Nevertheless, each modality has its own advantages and drawbacks. This is why bi- or multimodality approach seems interesting. Among them, PET/MRI combination seems very promising because it can bring complementary informations. It is therefore necessary to inject to patients tracers specific to each imaging modality. This work described the synthesis of molecular platforms for MRI and PET imaging, according to 2 different strategies. The first one consisted in the synthesis of a DO3A macrocycle allowing the chelation of both gadolinium for MRI and gallium 68 for PET. The aim here is to have a bimodal probe, with a mixture of each compound. The second strategy was the preparation of a single molecule that can be simultaneously labeled by both gadolinium for MRI and fluorine 18 for PET. The final goal is to introduce onto these platforms a biomolecule in a versatile and easy way, to be able to target a specific pathophysiological process. ‘‘Click’’ chemistry seems to be an attractive methodology to achieve this goal. However, this reaction, usually catalyzed with copper is not suitable to DO3A macrocyles due to the copper affinity with those azamacrocycles. This issue has been circumvent by the use of ruthenium catalyzed ‘‘click’’ chemistry. We were then able to access to both macrocycles platforms.
10

Marcadores moleculares derivados da bombesina para diagnóstico de tumores por spect e PET / Molecular markers derived from bombesin for tumor diagnosis by dpect and PET

PUJATTI, PRISCILLA B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:59Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:09/07417-9

Page generated in 0.0415 seconds