• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 303
  • 7
  • 1
  • 1
  • Tagged with
  • 319
  • 319
  • 268
  • 268
  • 178
  • 130
  • 130
  • 110
  • 89
  • 84
  • 78
  • 78
  • 68
  • 67
  • 64
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Análise comparativa de estratégias para regulação de tensão em sistemas de distribuição de energia elétrica na presença de geradores distribuídos / Comparative analysis of voltage regulation strategies in power distribution systems with distributed generators

Lucas Nery Padilha 02 July 2010 (has links)
Para que a instalação de geração distribuída possa de fato beneficiar a operação das redes de distribuição e de subtransmissão de energia elétrica, seus impactos técnicos devem ser cuidadosamente estudados, sobretudo em redes de distribuição, as quais foram inicialmente planejadas para operar com fluxo de potência unidirecional. Dentre esses impactos, a influência da geração distribuída na regulação da tensão é um aspecto de suma importância, pois está diretamente relacionada à qualidade do fornecimento da energia elétrica aos consumidores. Neste contexto, é importante conhecer e dispor de meios para controlar a interação entre esses geradores e os dispositivos convencionais de regulação de tensão (transformadores com comutadores de tap sob carga, bancos de capacitores e reguladores de tensão) para que a tensão de suprimento permaneça dentro da faixa de valores admissíveis. Assim, este projeto de pesquisa propõe uma análise comparativa entre diferentes estratégias de operação de dispositivos reguladores de tensão em sistemas de distribuição com a presença de geradores distribuídos. Algumas das metodologias discutidas aqui são bastante consolidadas e usualmente aplicadas na operação de sistemas de distribuição de energia elétrica e em trabalhos acadêmicos, enquanto outras são sugeridas por este mesmo trabalho. Tais estratégias são propostas como problemas de otimização não linear inteira mista em que se consideram diferentes modos de operação dos geradores distribuídos e duas funções-objetivo distintas, tratadas de forma independente: minimização dos desvios de tensão nas barras e minimização das perdas elétricas. Os resultados da aplicação de cada estratégia de operação são apresentados e é realizada uma análise qualitativa das vantagens e desvantagens de cada uma. Tem-se até o momento um conjunto de informações que podem servir de suporte na configuração de características operativas e definição de parâmetros de controle para o sistema de regulação de tensão das redes de distribuição de energia elétrica. / In order to assure that the installation of distributed generation would improve the operation of distribution and subtransmission networks, its technical impacts should be carefully studied, especially in distribution networks, which were originally designed to operate with unidirectional power flow. Among these impacts, the influence of distributed generation on voltage regulation is a very important aspect because it is directly related to the quality of electricity supply to the consumers. In this context, it is important to know and employ means of controlling the interaction between these generators and conventional voltage regulation devices (transformers with on-load tap changers, shunt capacitor banks and voltage regulators) assuring that the voltage supply remains within the range of permissible values. Thus, this work proposes a comparative analysis among different operational strategies of voltage regulation devices in distribution systems in the presence of distributed generators. Some of the methodologies discussed here are fairly consolidated and usually applied in power industry and academic researches, while others are suggested by this work. Such strategies are proposed as mixed integer nonlinear programming problems considering different operation modes of distributed generators and two different objective functions, treated independently: minimization of voltage deviations and minimization of power losses. The results of each operation strategy application are presented and a qualitative analysis of the advantages and disadvantages of each one is performed. So far, a set of information that may provide support to configure operating characteristics and define control parameters of voltage regulation system in power distribution networks has been generated.
82

Análise de requisitos técnicos para ilhamento intencional de geradores síncronos distribuídos / Analysis of technical requirements for intentional islanding of distributed synchronous generators

Rogério Lúcio Lima 09 August 2013 (has links)
Havendo qualquer distúrbio em um determinado sistema de distribuição de energia elétrica na presença de geradores distribuídos (GDs), é procedimento habitual exigido pelas concessionárias a desconexão destes na intenção de evitar a formação de um sistema ilhado eletricamente sustentado. Este procedimento tem como objetivo evitar maiores danos tanto ao sistema elétrico como um todo, principalmente ao próprio gerador distribuído, bem como às pessoas envolvidas na manutenção desse sistema. Entretanto, esse fato diminui consideravelmente as contribuições do conceito de geração distribuída à melhoria da qualidade dos serviços de fornecimento de energia elétrica por parte das concessionárias. Neste contexto, este trabalho possui como objetivo analisar os requisitos técnicos necessários para viabilizar a operação ilhada dos geradores distribuídos. Sabendo que a maioria das cargas presentes em um sistema de distribuição é dependente dos níveis de tensão e frequência da energia de suprimento, a análise e o monitoramento dessas grandezas antes e durante o ilhamento deverão ocorrer de forma que não se perca a estabilidade da rede ilhada. Para isto, devem ser avaliadas alterações nos métodos de operação e controle dos geradores distribuídos, de maneira a atender os requisitos técnicos necessários para manter a tensão e a frequência dentro dos parâmetros de qualidade de energia elétrica. Foram propostos quatro índices de desempenho para avaliar a qualidade da energia elétrica no sistema ilhado. Os resultados obtidos demonstram a necessidade de efetuar ações corretivas eficientes para manter o sistema elétrico ilhado operando dentro dos padrões aceitáveis de qualidade de energia elétrica. Foram investigadas soluções potenciais e viáveis para garantir a operação da ilha estável e com qualidade da energia elétrica. Além disso, observou-se que cargas dependentes da tensão podem influenciar significativamente a capacidade do GD em formar de ilhas estáveis. / If disturbances occur in a power distribution systems in the presence of distributed generators (DGs), a common practice required by utilities is to disconnect such generators, aiming at avoiding a self-sustained energized island. This procedure is required on order to prevent damage to the whole distribution system, mainly the DG, and to the utility maintenance personnel, as well. However, this requirement may decrease the possible contributions of the distributed generation concepts to the quality of the power supply. In this context, this work aims at analyzing the technical requirements related to make DGs islanded operation feasible. Since most of the loads are dependent on the supply voltage and frequency, the analysis and monitoring of such quantities before and after an islanding event should occur in such a way that the stability of the energized island is granted. To reach such a goal, changes in the DG control modes must be assessed, so that the technical requirements necessary to keep voltage and frequency within statutory limits are fulfilled. Four performance indices have been proposed to assess the power quality in the islanded system. The results have shown the need to perform efficient corrective actions to ensure reliable islanded operation. Moreover, it was observed that voltage-dependent loads may influence the DG capability to sustain stable islands.
83

Análise da influência de diferentes tipos de cargas no desempenho da proteção anti-ilhamento de geradores distribuídos / Analysis of influence of different types of loads on the performance of anti-islanding protection of distributed generators

Marcelo Moreira de Carvalho 04 September 2014 (has links)
A conexão de geradores distribuídos nas redes de subtransmissão e de distribuição de energia elétrica se mostra cada vez mais crescente devido aos inúmeros benefícios técnicos e econômicos alcançados com essa tecnologia. No entanto, há importantes implicações técnicas que precisam ser analisadas antes que um gerador distribuído seja conectado em paralelo ao sistema elétrico. Um aspecto a ser analisado, e que é comum entre as concessionárias de energia elétrica é a adequação da proteção anti-ilhamento, a qual tem a função de detectar essa condição e, automaticamente, desconectar os geradores distribuídos, dentro de um tempo pré-determinado, e assim mantê-los até que o fornecimento de energia seja restabelecido. Neste contexto, este trabalho analisará o desempenho dos relés de proteção anti-ilhamento em face de diferentes tipos de cargas que acabam afetando o tempo de detecção do ilhamento. Com isso, pretende-se obter subsídios para que os ajustes desses relés sejam calculados de forma eficiente. Os relés estudados são o relé de sub/sobrefrequência e o relé de taxa de variação da frequência, e o gerador distribuído é do tipo síncrono equipado com controle de tensão. As análises mostraram que no instante em que ocorre um ilhamento os fatores que mais influenciam no desempenho dos relés de proteção anti-ilhamento são as condições de carga e geração, tempo de detecção estabelecido, tipo do relé adotado, ajuste do mesmo e modelo de carga utilizado. / The connection of distributed generators to power subtransmission and distribution networks has been increasing recently due to the technical and economic benefits that such technology can provide. However, there are important technical issues that need to be carefully analyzed before a distributed generator is connected to electrical systems. One issue to be analyzed, which is common sense among utility companies, is the anti-islanding protection, whose main goal is to detect unintentional islanding and, automatically, disconnect the distributed generators within a required time-interval. In this context, this work will analyze the performance of anti-islanding protection relays in face of different load types. With this study, one intend to get support for adjusting these relays efficiently. The relays studied in this work are the under/over frequency and the rate of change of frequency relays, and the distributed generator is a synchronous machine equipped with an automatic voltage regulator. The analyzes showed that the moment a islanding occurs the most important factors influencing the performance of relays anti-islanding protection are the conditions of load and generation, detection time set, type and relay setting adopted and load model.
84

Metodologias para determinar a viabilidade técnica do ilhamento intencional de geradores distribuídos em sistemas de distribuição de energia elétrica / Methodologies for determining the technical feasibility of intentional islanding distributed generators in electric power distribution systems

Rogerio Lucio Lima 27 September 2018 (has links)
O ilhamento intencional quando desenvolvido em modo seguro pode ser considerado uma solução viável à promoção da confiabilidade das redes elétricas na presença de geradores distribuídos. Diante disso, esta tese de doutorado propõe metodologias que definem os ajustes das proteções do ponto de acoplamento comum e do gerador para viabilizar tecnicamente o ilhamento intencional, permitindo também avaliar a probabilidade de sucesso deste quando não planejado por um período de operação da rede. As metodologias propostas consideram os relés de deslocamento de fase ou \"salto de vetor\", relés de taxa de variação de frequência e os relés de sub/sobrefrequência convencionais. Estas metodologias baseiam-se na associação direta do tempo de detecção do ilhamento e do tempo de restrição. Estes tempos são oriundos da capacidade de detecção de ilhamento do relé baseado em medidas de frequência do ponto de acoplamento comum e da proteção do gerador. Os resultados foram consistentes e além de determinar a viabilidade técnica do ilhamento intencional de geradores distribuídos, permitiram avaliar a probabilidade de sucesso do ilhamento intencional. Adicionalmente, as metodologias permitiram definir quando possível os ajustes das proteções mais adequados à operação segura da ilha. / The intentional islanding when perfomed in a safe way can be considered a viable solution to the promotion of the reliability of the electrical networks in the presence of distributed generators. In this context, this doctoral thesis proposes methodologies that define the adjustments of the protections of the point of common coupling and the generator to technically enable the intentional islanding and allow to evaluate the probability of successful islanded operation. The proposed methodologies consider the vector surge or \"vector jump relays\", the rate of change of frequency and conventional under/overfrequency relays for islanding detection purposes, and the under/overfrequency relays to protect the generator. These methodologies are based on the direct association of the islanding detection time and the restriction time, and on their relation with the active power imbalance of the island. The detection and restriction times are derived from the islanding detection capability of the previous-mentioned relays, and from the generator protection, respectivelly. The results showed that the methodologies were able to identify favourable conditions for a successful islanded operation, and allowed assessing its probability of occurrence given different conditions of load and generation power imbalance. Additionally, the methodologies allowed to define, when possible, the adjustments of the most adequate protections for the isolated operation of the microgrid.
85

Metodologias de ajuste das proteções anti-ilhamento de geradores distribuídos considerando múltiplos eventos / Methodology to adjust distributed generation anti-islanding protections based on multiple events

Daniel Motter 16 November 2017 (has links)
Os geradores distribuídos em sistemas de distribuição de energia elétrica devem ser desconectados em eventos de ilhamento, que ocorrem quando parte da rede elétrica torna-se eletricamente isolada da concessionária e o subsistema isolado continua a ser energizado pela geração distribuída. A proteção anti-ilhamento deve detectar tal condição operativa, porém pode não atuar em condições de pequenos desbalanços entre carga e geração, ou atuar incorretamente para eventos de outra natureza. Assim, um ajuste adequado dessa proteção deve desconectar o gerador rapidamente quando detecta o ilhamento e, simultaneamente, deve ser imune a eventos como curtos-circuitos e chaveamentos de carga, por exemplo. Esta pode ser uma tarefa muito difícil face às variações de carga e diferentes eventos de não ilhamento que podem ocorrer no sistema de distribuição. Portanto, nesta tese são propostas metodologias de ajuste das funções de proteção anti-ilhamento de sub/sobrefrequência, taxa de variação de frequência, salto de vetor e sub/sobretensão, que são técnicas convencionalmente utilizadas para a detecção de ilhamento de geração distribuída. O objetivo das metodologias é maximizar a detecção de ilhamento e minimizar a atuação incorreta, e são considerados cenários com múltiplos geradores distribuídos de diferentes tecnologias. Inicialmente, são explorados os principais fatores que afetam as proteções, tais como distribuição das cargas, fator de potência e desequilíbrio das cargas. Esta análise permite identificar os casos mais difíceis de detecção de ilhamento. Como segunda contribuição, foi proposta a metodologia de análise gráfica denominada Mapa de Ajustes, cuja eficácia foi comprovada por meio de casos de teste, mostrando ser capaz de melhorar a sensibilidade da proteção anti-ilhamento e minimizar atuação incorreta. Na sequência, é apresentado um método automático para ajuste e bloqueio de tensão e outro baseado em proteção adaptativa para ajuste das funções de proteção. Ambos são baseados na metodologia de mapa de ajustes. Os resultados indicam que é possível melhorar a detecção de ilhamento e diminuir a atuação incorreta quando utilizadas as metodologias propostas. / Distributed generators in power distribution systems must be disconnected after an islanding event, which occurs when part of the power grid becomes electrically isolated from the utility and the isolated subsystem continues to be energized by the distributed generation. The antiislanding protection has to detect such operating condition, which may fail for critical loading conditions, or operate incorrectly for events of other nature than islanding. Therefore, an appropriate protection setting should quickly disconnect the generator when an islanding event is detected, and simultaneously, must be immune to events such as short circuits and load switches. This can be a very difficult task due to load variations and different nonislanding events that may occur in the distribution system. Therefore, in this thesis is proposed methodologies to adjust the anti-islanding protection functions of under/overfrequency, rate of change of frequency, vector surge and under/overvoltage, which are techniques conventionally used for islanding detection of distributed generation. The methodologies goals are to maximize the performance of the anti-islanding protection and minimize the incorrect operation to events of other nature, and scenarios with multiple distributed generators of different technologies are considered. At first, the main factors that affect the frequency and voltage-based protection will be explored, such as load distribution, power factor and unbalanced loads. This analysis aims to identify the most critical cases of islanding detection. The second contribution of this thesis is the Setting Map methodology, which is a graphical analysis whose effectiveness has been proved by case studies, showing to be able to improve the sensitivity of anti-islanding protection, minimizing the chances of incorrect operation. In sequence, is presented an automatic method to adjust the protection functions and voltage blocking and other based on adaptive protection. Both methods are based on the Setting Map methodology. The results indicate that it is possible to improve the islanding detection and reduce the incorrect actuation when it is used the proposed methodologies.
86

Metodologia de análise de variações de tensão causadas pela proteção anti-ilhamento de geradores síncronos distribuídos / Methodology for analysis of voltage variations caused by anti-island protection of distributed synchronous generators

Klaus Vieira do Nascimento 17 June 2013 (has links)
Nos últimos anos, fatores como a reestruturação do setor de energia elétrica, a necessidade de aproveitamento de diferentes fontes primárias de energia, dificuldades na construção de grandes unidades geradoras e linhas de transmissão causadas por normas de proteção ambiental têm provocado o aumento considerável do interesse por geração distribuída. O conceito de geração distribuída tornou-se muito interessante, entretanto, sua aplicação pode provocar problemas de qualidade de energia elétrica, caso sua influência não seja devidamente estudada. Neste contexto, este documento caracteriza as variações de tensão causadas pela atuação da proteção anti-ilhamento de geradores síncronos distribuídos. Este problema pode ser considerado uma nova abordagem sobre os impactos dos geradores distribuídos na qualidade da energia elétrica, visto que as causas das variações de tensão são tipicamente relacionadas às tomadas ou alívios de grandes blocos carga, partidas de motores de indução, curtos-circuitos, desligamentos de linhas etc. Para estudar o problema, inicialmente foi feito um estudo sobre normatização técnica da área com um apanhado dos guias de diversas concessionárias. Posteriormente, simulações computacionais utilizando o programa SimPowerSystems e um sistema teste foram utilizados para que análises estáticas e dinâmicas do problema fossem feitas no intuito de investigar a natureza das variações de tensão e os fatores que influenciam suas magnitudes e durações. Índices para avaliar as variações de tensão foram criados, e um método para obtenção dos mesmos foi proposto. Tal método utiliza apenas ferramentas de análise estática (fluxo de carga) para a obtenção dos índices, evitando o uso de ferramentas dinâmicas (domínio do tempo) reduzindo o custo computacional e financeiro para análise do problema. Em seguida, o mesmo foi aplicado a um sistema que simula uma rede de distribuição real propondo-se a inserção de bancos de capacitores como medida mitigatória para o problema estudado neste trabalho. / In recent years, factors such as the restructuring of the electricity sector, the necessity to use different primary energy sources as a way to diversify sources of energy, barriers in the construction of large generating units and transmission lines caused by environmental protection standards, as well as technological advances in the generation of electricity, have caused a considerable increase in the interest for distributed generation. The concept of distributed generation has become very interesting; however, its application can result in poor power quality, if its influence is not well studied. In this context, this document characterizes voltage variations caused by the action of anti-islanding protection of distributed synchronous generators. This problem can be considered a new approach on the impact of distributed generators in power quality, since the cause of voltage variations are typically related load switching, induction motors start-up, short circuits, lines disconnection, etc. To investigate the problem, initially a study was carried out on technical standardization in the area with an overview of various utilities guides. Later, computer simulations using the SimPowerSystems software and a test system were employed for static and dynamic analysis of the problem, aiming at investigating the nature of voltage variations and the main factors that influence their magnitudes and durations. Indices to assess the voltage variations were created, and a method for obtaining them was proposed. This method uses only static approach tools (power flow calculations) to obtain the indices, avoiding the use of dynamic tools (time-domain simulations) and reducing computational and financial costs to analyses the problem. The proposed method was applied to a larger system and the insertion of capacitors bank was proposed as mitigating solution for the problem studied in this work.
87

Metodologia para avaliação da influência de geradores distribuídos nos níveis de curto-circuito em sistemas de distribuição de energia / Methodology for assessment of distributed generators Influence on short circuit levels of power distribution systems

Daniel Petean 27 February 2015 (has links)
A instalação de geração distribuída nas redes de distribuição e de subtransmissão de energia elétrica tem apresentado significativo crescimento em âmbito mundial, impulsionada pelos benefícios que pode proporcionar aos sistemas elétricos, pela necessidade de diversificação da matriz energética dos países, pela desregulamentação do setor de energia elétrica em diversos países e pela necessidade de gerar energia elétrica de forma sustentável. No entanto, para que os geradores distribuídos possam de fato beneficiar a operação das redes elétricas, seus impactos técnicos devem ser cuidadosamente estudados, sobretudo em redes de distribuição, as quais foram inicialmente planejadas para operar com fluxo de potência unidirecional. Dentre esses impactos, destaca-se a elevação do nível de curto-circuito da rede, pois correntes de curto-circuito com valores elevados podem causar violação das capacidades dos equipamentos em suportar os esforços térmicos e dinâmicos e também provocar a perda da coordenação entre os dispositivos de proteção contra sobrecorrente. Neste contexto, este trabalho analisa a influência de geradores distribuídos baseados em inversores na corrente de curto-circuito trifásica em um sistema de distribuição de energia, e sobretudo, comprova que sua contribuição no valor da corrente de falta não supera o dobro de sua corrente nominal. Além disso, com base nesta comprovação, apresenta duas estratégias para inserção desse tipo de gerador nos cálculos de curto-circuito de um sistema de distribuição de energia elétrica. As duas estratégias apresentam resultados satisfatórios, utilizam conceitos básicos de circuitos elétricos, independem de dados minuciosos dos inversores e são validadas através de aplicações numéricas com resultados confrontados aos obtidos das simulações. / The installation of distributed generation in distribution and subtransmission systems has shown significant growth worldwide, driven by the benefits it can provide to electrical systems, the need to diversify the energy sources, deregulation of the electricity industry in several countries and the need to generate electricity in a sustainable manner. However, in order to evaluate if distributed generators benefit the operation of power networks, their technical impacts should be carefully studied, especially in distribution networks, which were originally designed to operate with unidirectional power flow. Among the aforementioned impacts, there is the increase of the short circuit level in the distribution network, since high short-circuit currents may exceed the capabilities of equipment to support the dynamic and thermal stresses and also cause loss of coordination between the overcurrent protection devices. Within this context, this thesis analyzes the influence of inverter based distributed generators on three-phase short circuit currents in a power distribution systems. Especially it confirms that the contribution to the fault current does not exceed twice its rated value. Furthermore, based on this issue, this work presents two strategies for the inclusion of this type of generator in short circuit calculations. Both strategies presented satisfactory results, use basic concepts of electrical circuits, they do not depend on detailed data from the inverters and the results are validated by using simulation results.
88

A integração da geração fotovoltaica distribuída à matriz elétrica brasileira: uma análise sob a ótica institucional / The integration of the photovoltaic distributed generation on Brazilian electric matrix: an analysis from the institutional perspective

João Marcos Mott Pavanelli 19 December 2016 (has links)
A matriz brasileira de energia elétrica foi construída historicamente como resultado da confrontação de interesses econômicos, políticos e sociais. Graças a avanços tecnológicos, o setor elétrico brasileiro passa por uma fase de possível inserção de novos modelos, como a geração distribuída de fontes energéticas alternativas, como eólica, biomassa e solar fotovoltaica. Este trabalho oferece uma análise institucional para a compreensão das possibilidades de inserção da geração distribuída fotovoltaica na rede elétrica. Essa análise institucional foi feita através de uma triangulação de técnicas, partindo de revisão bibliográfica de literatura científica, que gerou um modelo analítico para identificar e classificar os principais marcos históricos que direcionaram a estruturação da matriz energética brasileira. Os dados foram confrontados com as entrevistas em profundidade com especialistas do setor elétrico. Os resultados fundamentaram modelos que descrevem a formação histórica de instituições sob os aspectos econômicos, técnicos e normativos. Além disso, os resultados indicam um cenário favorável para investimentos em geração distribuída fotovoltaica até o final da década de 2020, mas também sugerem um possível conflito de equacionamento de custos entre os geradores distribuídos e as concessionárias de distribuição de energia elétrica / The Brazilian electric matrix was built historically as a result of the confrontation among economic, political and social interests. Given the technological advance, the Brazilians electric sector can introduce new models of electric generation, as the distributed generation from alternative energy sources as wind, biomass and photovoltaics. This study offers an institutional analysis to comprehend the perspectives of introducing distributed generation from photovoltaics on Brazilian electric network. This institutional analysis undertook a triangulation of techniques, starting from a literature review, which supported an analysis model. This model was used to identify and classify the main historic marks that constrained the choices concerning the Brazilians electric matrix composition. Historical data was confronted to in-depth interviews with specialists of the Brazilians electric sector. Results supported models which describe the historic formation of institutions under economic, technical and normative aspects. Furthermore the results indicate a favorable scenario to invest in distributed generation from photovoltaic systems in Brazil, at least until 2020, but they also forecast a possible conflict concerning the balance of some costs between the local energys distributor and the owners of distributed generation systems
89

Controle e análise de conversores CC-CA conectados em redes de distribuição e utilizados em sistemas de geração distribuída / Analysis and control of DC-AC power converters connected to a distribution grid and use in distributed generation system

Amílcar Flamarion Querubini Gonçalves 14 March 2011 (has links)
O presente trabalho visa o desenvolvimento de metodologias para a conexão de sistemas de Geração Distribuída (GD) em redes de distribuição utilizando conversores CC-CA como também, a produção de energia elétrica dentro dos padrões estabelecidos por normas nacionais e internacionais. Para a produção de energia com índices de qualidade satisfatórios, duas situações vão ser consideradas: uma quando o sistema está conectado à rede e outra quando a rede está indisponível. Após a ocorrência do ilhamento, é necessária a mudança da variável a ser sintetizada pelo conversor CC-CA, ou seja, antes da contingência ocorrer a GD está sendo gerenciada no modo potência e/ou corrente e após passa a ser controlada no modo tensão. Além disso, espera-se que os resultados obtidos forneçam subsídios às concessionárias de energia elétrica e aos produtores e autoprodutores de energia para a conexão sistemas de geração distribuída em redes de distribuição como também, os procedimentos necessários a serem adotados por eles quando o sistema de distribuição estiver sob contingência (ilhamento). / This work proposes a set of analysis to connecting a distributed generation system to a distribution network using a three-phase power converter (DC-AC) as well as, the power generation produced by the DG (Distributed Generation) system must follow the national and international power quality standards. For producing energy with satisfactory power quality indexes, two situations will be considered: when the power converter operates connected to the grid, the power/current is used as control variable. However, if the power converter is operating in stand-alone mode (contingency or islanding mode) the control variable must be changed to voltage and the terminal voltage of the power converter must be controlled. Finally, the main concerning of the present study is to obtain results to the electrical energy companies and self-producers for connecting DG system to the grid as well as, the essential procedures that must be adopted by them when the distribution system is operating in contingency or islanding mode.
90

Avaliação da estabilidade de tensão nos sistemas de distribuição considerando a injeção de potência da geração distribuída / Voltage stability assessment in distribuition systems considering the power injection by distributed generation

Alves, Alessandro Arjona 01 April 2016 (has links)
Made available in DSpace on 2017-07-10T16:41:33Z (GMT). No. of bitstreams: 1 Dissertacao Alessandro Arjona Alves2 - Final.pdf: 1729270 bytes, checksum: eaef13266354526fc7d7558b8d6748d0 (MD5) Previous issue date: 2016-04-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The huge rise in electricity energy demand seen in recent decades, the growing interest in alternative and renewable energy sources have placed the distributed generation (DG) in evidence in the global energy landscape. This scenario brings a significant growth in the use of this energy source. Thus, different types of interface and primary sources of energy, with the possibility of allocating different points in the network and with different capabilities, distributed generation brings different impacts to the distribution systems, including power system voltage stability. The voltage stability in networks with distributed generation is the object of this study. To this end, it has been studied methods for power flow calculation, the fundamental concepts of voltage stability and methods of analysis. The aim of this research is to evaluate the distributed generation impact on the voltage stability. Therefore, it has been evaluated some technical aspects such as power factor, location and generation capacity. Through the development of the analysis it was possible to highlight the relationship between improvement in stability margin and the benefit in reducing losses caused by GD. Also it was found that, with a view to improving the margin of voltage stability, it is more efficient to inject power in the network with the same power factor of the system equivalent load. / O grande aumento de demanda por energia elétrica verificado nas últimas décadas, o crescente interesse por fontes alternativas e renováveis de energia tem colocado a geração distribuída (GD) em evidência no panorama energético mundial. Esse cenário propiciou um grande crescimento do uso deste tipo de fonte de energia. Assim, com diferentes tipos de interface e de fontes primárias de energia, com a possibilidade de alocação em distintos pontos da rede e com diferentes capacidades, a geração a distribuída traz diferentes impactos às redes de distribuição, inclusive à estabilidade de tensão dos sistemas. A estabilidade de tensão em redes com presença de geração distribuída é o objeto de estudo desta dissertação de mestrado. Neste sentido, são estudados os métodos para cálculo de fluxo de potência, os conceitos fundamentais da estabilidade de tensão e métodos de análise. O objetivo deste trabalho de pesquisa é avaliar os impactos da geração distribuída na estabilidade de tensão. Para tanto, foram avaliados alguns aspectos técnicos como fator de potência, localização e capacidade de geração. Através das análises desenvolvidas foi possível destacar a relação entre melhora na margem de estabilidade de tensão e o benefício em redução de perdas ocasionado pela GD. Também constatou-se que, com vistas à melhora da margem de estabilidade de tensão, é mais eficiente injetar potência na rede com o mesmo fator de potência da carga equivalente do sistema.

Page generated in 0.0797 seconds