• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 8
  • 1
  • 1
  • Tagged with
  • 50
  • 18
  • 18
  • 17
  • 13
  • 13
  • 10
  • 10
  • 9
  • 9
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo da geração de nanopartículas a partir da atomização de soluções de cloreto de sódio

Amaral, Clarice Dias do 22 February 2010 (has links)
Made available in DSpace on 2016-06-02T19:56:37Z (GMT). No. of bitstreams: 1 2844.pdf: 8104591 bytes, checksum: 25c355afee14c3195e1a845ce51e8e6e (MD5) Previous issue date: 2010-02-22 / Universidade Federal de Sao Carlos / Particles of nanometric dimensions are subjected, in recent years, to extensive research all over the world, not only for the possible risks that they cause when inhaled, but also for the wide range of applications and improvements obtained with their employment. An interesting and economical form of generating these particles in the nanometric scale is through the atomization of a salt solution. With the atomization of the solution, a cloud of drops is generated, which is subsequently evaporated by heat exchange with the surrounding gas. The salt nanoparticles are then incorporate in the flowing gas, forming an aerosol. In this method, the size of the particles can be controlled by changing the concentration of the atomized solution. The present work had as objective the study of this generation mechanism. This study was made through the investigation of the size distributions of drops and particles at different salt concentrations. The nanoparticles were generated through the atomization of solutions of sodium chloride that were characterized regarding their density, viscosity and surface tension. In the atomization process two different atomizers were utilized. They were made of different material and geometry, but both were twin-fluid (gas-liquid) atomizers. One of the atomizers was built in the at DEQ-UFSCar and the other was a commercial inhalator named NS. The measurements of drop size distribution were made using the equipment Malvern Spraytec. The distribution of sizes and concentration of the particles were obtained through the electrical mobility particle analyzer SMPS, from TSI, where the sampling was made directly from the aerosol. The results showed that the increase in the concentration of the saline solution resulted in an increase of the particles median diameter. Also, an increment in the number of particles was observed with the increase in the saline solution concentration. The drop size distribution was associated to the physical properties of each solution and they did not show considerable variations as the solution of NaCl became more concentrated. These results discard the possibility that the number of particles increases due to an increment in the number of drops with salt concentration, since their size was virtually the same in all tests performed. The increase in the total number of nanoparticles is probably due to the drying mechanism of the drops. It was evidenced that a single drop generates more than a particle and that tendency increases with the concentration of the saline solution, tending asymptotically to a constant value. An empiric expression correlating the number of particles generated to the saline concentration of the atomized solution it is proposed and it represents well the experimental data. / Partículas de dimensões nanométricas estão, desde alguns anos, sendo alvo de pesquisa em todo o mundo, não apenas pelos possíveis riscos que oferecem quando inaladas, mas também pela ampla gama de aplicações e aperfeiçoamentos obtidos com o seu emprego. Uma forma interessante e econômica de gerar estas partículas de escala nanométrica é através da atomização de uma solução contendo sal. Com a atomização da solução, gera-se uma nuvem de gotas que são evaporadas pela troca de calor com o ambiente. As nanopartículas de sal são então incorporadas na corrente de ar seco, formando um aerossol. Neste método, o tamanho das partículas pode ser controlado pela concentração da solução atomizada. O presente trabalho teve como objetivo estudar o esse mecanismo de geração de nanopartículas. Este estudo foi feito através da investigação das distribuições de tamanho de gotas e partículas para diferentes concentrações de sal. As nanopartículas foram geradas através da atomização de soluções de cloreto de sódio de diferentes concentrações, sendo que tais soluções foram caracterizadas quanto à densidade, viscosidade e tensão superficial. No processo de atomização trabalhou-se com dois atomizadores distintos quanto ao material e geometria, mas ambos eram do tipo duplo-fluido (gás-líquido). Um dos atomizadores foi construído nas dependências do DEQ-UFSCar e o outro era um inalador comercial da marca NS. As medidas de distribuição de tamanhos das gotas foram feitas utilizando o equipamento Malvern Spraytec. A distribuição de tamanhos e a concentração das partículas foram determinadas por meio de um Analisador de Partículas por Mobilidade Elétrica (SMPS), da TSI, sendo a amostragem feita diretamente no aerossol. Os resultados referentes às nanopartículas mostraram que à medida que se aumentou a concentração da solução salina, observou-se um aumento do diâmetro médio das partículas, assim como um incremento no número das mesmas. Os dados de distribuição de tamanho de gotas foram associados às propriedades físicas de cada solução e não mostraram variações consideráveis à medida que a solução de NaCl tornava-se mais concentrada. Os resultados descartam a possibilidade de que o número de partículas aumente devido a um incremento no número de gotas, já que o diâmetro das mesmas foi virtualmente o mesmo em todos os testes realizados. O aumento do número total de nanopartículas é provavelmente devido ao mecanismo de secagem das gotas. Ficou evidenciado que uma gota gera mais que uma partícula e que essa tendência aumenta com a concentração da solução salina, tendendo assintoticamente a um valor constante. Uma expressão empírica correlacionando o número de partículas geradas à concentração salina da solução atomizada é proposta e representa com fidelidade os dados experimentais.
22

Estudo do efeito da redução de atrito hidrodinamico em soluções polimericas nas estruturas produzidas pelo impacto de gotas / Study of hydrodynamic drag reduction polymericsolutions based on the drop impact images

Alkschbirs, Melissa Inger 12 July 2004 (has links)
Orientadores: Edvaldo Sabadini, Marcelo G. de Oliveira / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-04T14:22:34Z (GMT). No. of bitstreams: 1 Alkschbirs_MelissaInger_D.pdf: 20703558 bytes, checksum: 093e76dc07818947b87478f9a799ad47 (MD5) Previous issue date: 2004 / Resumo: O efeito da redução de atrito hidrodinâmico em soluções poliméricas nas estruturas produzidas pelo impacto de gotas foi determinado por meio da análise de imagens obtidas utilizando uma câmera CCD e um programa de tratamento de imagens. O impacto de uma gota contra uma superficie líquida causa o fenômeno conhecido como splash, onde duas principais estruturas são formadas: a coroa e o jato Rayleigh. A altura máxima atingida pelo jato Rayleigh foi utilizada como parâmetro para determinar a redução de atrito hidrodinâmico, proporcionada pela presença de pequenas quantidades (ppm) de polímeros de elevada massa molar presentes em solução. A capacidade redutora de atrito hidrodinâmico do poli( óxido de etileno ), PEO, o mais eficiente agente redutor de atrito, foi estudada em função da qualidade do solvente, da temperatura, da concentração, da massa molar e da flexibilidade intrínsica da cadeia polimérica. As modificações decorrentes de alguns destes fatores sobre o raio de giração do polímero e, conseqüentemente sobre o tempo de relaxação e a viscosidade elongacional, são responsáveis pelas modificações morfológicas observadas no jato Rayleigh. Estudos temporais da evolução do splash também foram desenvolvidos, onde se procurou correlacionar a taxa de deformação do líquido com o tempo de relaxação da cadeia polimérica. O presente trabalho mostra, de forma inédita, que é possível utilizar o splash nos estudos sobre a redução de atrito hidrodinâmico / Abstract: The presence of very small amounts (ppm) of high-molecular weight polymers in a solution produces high levels of drag reduction in a turbulent flow. This phenomenon, termed as the Toms Effect, was studied using images of the impact of a small drop against shallows liquid surfaces, both liquids containing a drag reducer agent. After the impact a crown and a cavity are created and the collapse of these structures impels a liquid column, named as Rayleigh jet. This phenomenon is termed splash. The amplitude reached by the Rayleigh jet was used to estimate the energy of the drop stored in the liquid; therefore, the maximum height of the jet allow us to determine the percentage of drag reduction. The results were discussed in terms of different parameters such as polymer concentration, molecular weight in the poly(ethylene oxide), PEO, the most efficient drag reducer agent in aqueous system. The splash in aqueous polymeric solution is dominated by the elongational viscosity and therefore, the polymer relaxation time has an important role in the process. We consider that the main contribution of this work to the drag reduction field is the new approach proposed to investigate this old hydrodynamic phenomenon / Doutorado / Físico-Química / Doutor em Quimica
23

Um novo método para medidas de gotas de chuva com técnicas do processamento digital de imagens / not available

Ana Cláudia Martinez 24 June 2002 (has links)
Um novo método para avaliação do tamanho de gotas de chuva e sua distribuição é apresentado. O método é baseado no processamento de imagens com o uso da transformada de Hough circular em conjunto com as técnicas de Backmapping e análise de vizinhança. Esta metodologia trás vantagens, uma vez que viabiliza medidas diretas e de forma automática para identificação e contagem de gotas de chuva. A calibração do método foi desenvolvida utilizando padrões de gotas conhecidos. Gotas, na faixa de 1 &#956m a 85 mm de diâmetro, foram automaticamente reconhecidas e medidas com sucesso. Resultados mostram erro médio percentual não maior que 3,61%. Adicionalmente é apresentado uma comparação de resultados obtidos com um método de análise de correlação em frequência e contagem direta. Resultados mostram a potencialidade da metodologia desenvolvida para aplicações agrícolas. / A new method for evaluating raindrop size and distribution has been developed. It is based on image processing with circular Hough fast transform composed with the Backmapping and neighborhood analysis techniques. This methodology has the advantage of being a direct measurement method that automatically identifies and counts raindrops. Calibration was carried out using standard patterns with known raindrop sizes. Drops sizes ranging from 1 &#956m sizes to 85 mm in diameter has been automatically recognized and successfully measured. Results show perceptual average error not larger than 3,61%. In addition a comparison of results with the correlation analysis in the frequency domain and directed counts methods are presented. Results show the suitability of developed methodology.
24

ESPAÇAMENTO ENTRE LINHAS E PONTAS DE PULVERIZAÇÃO NO CONTROLE DE Phakopsora pachyrhizi Sidow / ROW SPACINGS AND SPRAY NOZZLES IN THE Phakopsora pachyrhizi Sidow CONTROL

Madalosso, Marcelo Gripa 26 February 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The association of application technology with the crop handling can provide larger adaptation in the phytosanitary handling as well as increasing the exhibition of the leaves to the radiation. This work had for objective to assess the effect of row spacings and spray nozzles interaction in asian rust (Phakopsora pachyrhizi Sidow) control. The experimental design was a randomized blocks with four replications, in bands with split split-plots. The research was carried out in Itaara RS wher the cultivar M-SOY 8000 RR was sowed in row spacings of 30, 45 and 60 cm, keeping the same plants population of 33 pl.m-2. The spray nozzles used were extended range flat (XR 11001), twinjet flat spray (TJ60-11002), hollow cone spray (TXA 8002) and Turbo Teejet® Duo (TT 11002 + XR 11002). The applications were designed in split splitplots with one, two and three applications. The results showed that the reduction of the row spacing benefited the disease action. The row spacing of 60 cm presented the smallest severity values, rate of disease progress (r) and Area Under Disease Progress Curve (AUDPC). When the row spacing was reduced, the previous values were increasing gradually. Thus, the defoliate was larger in row spacings of 30 and 45 cm and the Green Foliate Area (GFA) was obtained better levels in the row spacing of 60 cm. The fungicide covering was larger in the row spacing of 60 cm as in medium as in inferior stratum for all analyzed spray nozzles. The number of pods and number of grains per pods were significantly larger in the row spacing of 60 cm mainly in the inferior stratum, resulting in a superior final productivity than row spacing of 30 and 45 cm, benefited for the largest foliate covering and photosynthetic activity of the inferior and medium stratum. / A associação da tecnologia de aplicação com o manejo fitotécnico pode proporcionar maior adequação no manejo fitossanitário assim como aumentar a exposição das folhas à radiação. O presente trabalho teve por objetivo avaliar o efeito da interação de espaçamentos entre linhas da soja com diferentes pontas de pulverização visando controle da ferrugem asiática (Phakopsora pachyrhizi Sidow) da soja. Para isso foi utilizado o delineamento experimental de blocos ao acaso com parcelas subsubdivididas. O trabalho foi conduzido em Itaara RS onde a cultivar de soja M-SOY 8000 RR foi semeada com espaçamentos de 30, 45 e 60 cm entre linhas, mantendo a mesma população de plantas de 33 pl.m-2. Foram utilizadas pontas de pulverização de jato leque plano de uso ampliado (XR 11001), jato plano duplo comum (TJ-60 11002), cone vazio (TXA 8002) e Turbo TeeJet® Duo (TT 11002 + XR 11002), trabalhadas com pulverizador costal propelido à CO2. As aplicações foram escalonadas nas subsubuparcelas com uma, duas e três aplicações. Os resultados obtidos mostraram que a redução do espaçamento entre linhas favoreceu a ação da doença. O espaçamento de 60 cm apresentou os menores valores de severidade, taxa de progresso (r) da doença e Área Abaixo da Curva de Progresso da Doença (AACPD). À medida que o espaçamento foi reduzido, os valores citados foram aumentando gradativamente. Por conseqüência, a desfolha foi maior nos espaçamentos de 30 e 45 cm e a Área Foliar Verde (AFV) obteve melhores níveis no espaçamento de 60 cm. A cobertura do fungicida foi superior no espaçamento de 60 cm, tanto no dossel mediano como no inferior para todas as pontas analisadas. Com relação à produtividade, seus componentes, como número de vagens e número de grãos por vagem foram significativamente superiores no espaçamento de 60 cm, principalmente no dossel inferior, favorecido pela maior cobertura foliar e atividade fotossintética dos dosséis inferior e mediano, resultando em uma produtividade final superior aos espaçamentos de 45 e de 30 cm.
25

Lípidos nucleares: topología y metabolismo

Layerenza, Juan Pablo 20 December 2013 (has links)
El núcleo es una de las características distintivas que definen a las células eucariotas, permite una compartamentalización que es crítica para procesos que se desarrollan dentro del mismo, como la replicación, transcripción, splicing de pre-mRNA y ensamblado de ribosomas. Los Lípidos Neutros (LN) nucleares son fuentes alternativas de ácidos grasos (FA) y colesterol para membranas, vías de señalización y ligandos de factores de transcripción. Los objetivos de la presente tesis fueron: 1) Determinar la organización estructural y espacial de los lípidos nucleares. 2) Determinar el o los mecanismos de incorporación de los ácidos grasos (FA) exógenos en los lípidos nucleares. Como modelo experimental se trabajó con núcleos y matrices nucleares aislados de hígado de rata. La pureza de las fracciones aisladas se determinó mediante ensayos morfológicos y bioquímicos y se corroboró la alta pureza e integridad de cada fracción. Mediante análisis bioquímicos tradicionales se determinó la composición lipídica nuclear y se pudo concluir que los lípidos nucleares se ubican en dos localizaciones principales, la doble membrana nuclear compuesta de glicerofosfolípidos, esfingolípidos y colesterol; y dentro del núcleo, los lípidos endonucleares están enriquecidos en triacilglicéridos (TAG) y ésteres de colesterol (CE). En particular, los LN nucleares se organizan en la matríz nuclear como Gotas Lipídicas nucleares (nLD), que serían análogas a las gotas lípidicas citosólicas (cLD). Esta hipótesis fue corroborada al observar nLD en el interior de núcleos y matrices aislados de hígado de rata, en hepatocitos de rata y en células HepG2, mediante microscopía de campo claro y de fluorescencia en muestras tratadas con coloraciones específicas para lípidos. Las nLD se caracterizan por ser esferas, de número limitado por núcleo y estar separadas espacialmente de los dominios nucleares nucleolo, Speckles y Paraspeckles y lámina nucleas. Poseen además diámetros menores a los de las cLD. Se elaboró un protocolo para aislar nLD de los demás componentes nucleares y se corroboró la presencia de gotas de lípidos en la fracción aislada por microscopía de campo claro y electrónica con tinciones específicas. Las nLD son estructuras supramoleculares nucleares compuestas principalmente por CE, C, TAG y proteínas, con una baja proporción de lípidos polares. Las nLD constituyen un nuevo dominio nuclear donde los LN se almacenan y organizan y seguramente participan en la homeostasis lipídica nuclear. Las nLD podrían actuar como un sistema buffer endonuclear proveyendo o incorporando lípidos y proteínas involucrados en diferentes procesos. Se determinó que la membrana nuclear corresponde a una zona de fluidez mayor a la de la membrana plasmática y la matriz nuclear es más rígida, utilizando la sonda Laurdan y microscopía de 2 fotones. Para evaluar el mecanismo de incorporación FA exógenos en los lípidos nucleares se incubaron núcleos con distintos [14C]FA y se analizó la incorporación de la radiactividad en los lípidos. Los FA saturados y polinosaturados exógenos estudiados se incorporan como FA y se esterifican en los lípidos nucleares. Los FA no se esterifican directamente a los pooles lipídicos nucleares sino que primero deben ser convertidos en ésteres de CoA. Este proceso es llevado a cabo por acción de acil-CoA sintetasas. Los ácidos 16:0, 18:0, 18:1n-9, 18:2n-6 y 20:4n-6 se esterifican en los lípidos nucleares. Los FA ensayados se incorporan como FA libre tanto en núcleos, membranas nucleares aisladas, matrices nucleares como en las nLD y se esterifican en los lípidos de las mismas (LP y LN en los núcleos, matrices y nLD y LP en las membranas nucleares). Sin embargo, los FA no se esterifican en lípidos de nLD aisladas en las condiciones ensayadas, esto pude deberse a que se necesiten componentes nucleares que se pierden durante el aislamiento o que no haya remodelado de FA dentro de la gota. La L-FABP participa en la movilización y transporte de FA nucleares. Existe un transporte reverso de FA unidos a L-FABP desde los pooles lipídicos nucleares y endonucleares (matrices nucleares) hacia el citosol. La L-FABP moviliza al 20:4n-6, 18:0 y 18:1n-9 fuera del núcleo hacia otros compartimentos celulares. Estimula la movilización y redistribución de los mismos dentro del núcleo entre los diferentes pooles lipídicos. En especial, determina un incremento de 20:4n-6 esterificado en PI. El PI de la matriz nuclear forma parte del activo sistema de transducción de señales del núcleo, y la L-FABP estaría favoreciendo la adecuada composición de este fosfolípido. El 20:4n-6 movilizado por la L-FABP de los pooles endonucleares, podría ser el ligando de factores de transcripción, en particular del PPARα, dado que existe colocalización entre PPARα y L-FABP. / Los resultados obtenidos de esta tesis fueron premiados en las Jornadas de Lípidos 2012 de la Facultad de Farmacia y Bioquímica de la Universidad de Buenos Aires (UBA).
26

Evaluation of emulsion destabilization by light scattering applied to metalworking fluids. / Avaliação da desestabilização deemulsões por espalhamento de luz, aplicada a fluídos de corte.

Assenhaimer, Cristhiane 25 August 2015 (has links)
Monitoring of emulsion properties is important in many applications, like in foods and pharmaceutical products, or in emulsion polymerization processes, since aged and broken emulsions perform worse and may affect product quality. In machining processes, special types of emulsions called metalworking fluids (MWF) are widely used, because of its combined characteristics of cooling and lubrication, increasing the productivity, enabling the use of higher cutting speeds, decreasing the amount of power consumed and increasing tool life. Even though emulsion quality monitoring is a key issue in manufacturing processes, traditional methods are far from accurate and generally fail in providing the tools for determining the optimal useful life of these emulsions, with high impact in costs. The present study is dedicated to the application of a spectroscopic sensor to monitor MWF emulsion destabilization, which is related to changes in its droplet size distribution. Rapeseed oil emulsions, artificially aged MWF and MWF in machining application were evaluated, using optical measurements and multivariate calibration by neural networks, for developing a new method for emulsion destabilization monitoring. The technique has shown good accuracy in rebuilding the droplet size distribution of emulsions for monomodal and bimodal distributions and different proportions of each droplet population, from the spectroscopic measurements, indicating the viability of this method for monitoring such emulsions. This study is part of a joint project between the University of São Paulo and the University of Bremen, within the BRAGECRIM program (Brazilian German Cooperative Research Initiative in Manufacturing) and is financially supported by FAPESP, CAPES, FINEP and CNPq (Brazil), and DFG (Germany). / Sem resumo em português.
27

Gotas e pontes capilares na escala nanométrica / Droplets and capillary bridges at the nanoscale

Almeida, Alexandre Barros de 12 April 2017 (has links)
O fenômeno da capilaridade na escala macroscópica é descrito pela teoria capilar (TC) que se utiliza de superfícies contínuas para modelar as interfaces formadas entre dois meios, sendo um líquido e o outro líquido, gasoso, sólido. A TC é empregada em diversas áreas da biologia, ambientes de microgravidade e em aplicações na escala nanométrica, como no microscópio de força atômica. Essa aproximação por superfícies contínuas pode não ser adequada para sistemas na escala nanométrica, em que são reportados comportamentos anômalos como no preenchimento de líquidos em nanocanais e nanotubos de carbono, oscilações nas medidas de força de adesão capilar e grandes valores de pressões de Laplace negativas. Esses fatos motivam o estudo do fenômeno da capilaridade na escala nanométrica por meio de simulações computacionais. Aqui, utilizamos a dinâmica molecular para estudar a interface de gotas e pontes capilares constituídas de água do modelo SPC/E com volumes da ordem de 100 nanômetros cúbicos e aderidas a placas de cristobalita hidrofóbicas/hidrofílicas. Comparamos as propriedades dessas gotas e pontes capilares com as previsões da TC macroscópica, que são baseadas nos ajustes dos perfis e em cálculos analíticos. Especificamente, confrontamos os perfis das interfaces, os ângulos de contato, as forças de adesão capilar, as pressões de Laplace e o valor da tensão superficial da água. Essas análises foram divididas em três etapas. Na primeira etapa, estudamos as gotas e pontes capilares com simetrias axial e translacional, em que a altura da ponte capilar permaneceu constante. Na segunda etapa, focamos nossos estudos nas pontes capilares com simetria axial (ponte SA) e estudamos o processo de ruptura dessa. Finalmente, na terceira etapa, estudamos as flutuações, que não são previstas pela TC, em sistemas mais simples, como no caso de gotas livres, que não estão aderidas a placas, e em gotas com simetria axial. Mostramos que a TC macroscópica é capaz de explicar satisfatoriamente sistemas com volumes da ordem de 100 nanômetros cúbicos, em que submetemos nossos resultados a comparações rigorosas das soluções analíticas da TC, sendo essa capaz de prever a dependência do ângulo de contato nas alturas das rupturas das ponte SA e os volumes das gotas formadas após a ruptura. / The capillarity phenomenon at macroscopic scale are described by the capillarity theory (CT), which uses continuous surfaces to model the interfaces formed between two media, wherever one medium is liquid and the other can be liquid, gas or solid. The CT is employed in several areas ranging from biology, microgravity environments and applications on the nanoscale, such as in the atomic force microscope. However, the continuous approach may not be adequate for systems at nanoscale, where anomalous behaviors have been reported, such as the filling of liquids in nanochannels and carbon nanotubes, oscillations in measurements of capillary adhesion force and large negative values of Laplace pressures. These facts motivate the study of capillarity phenomenon at the nanometric scale by computational simulations. Here, we use the molecular dynamics to study the droplets and capillary bridges interfaces composed of SPC/E water model and volumes in the order of 100 cubic nanometer, and attached to hydrophobic/hydrophilic cristobalite walls. We have compared the droplets and capillary bridges properties with the macroscopic CT predictions, which are based on profile fitting and analytic calculations. Specifically, we have compared the interface profiles, the contact angles, the capillary adhesion forces, the Laplace pressures and the water surface tension. These analyzes were divided into three steps. In the first step, we have studied droplets and capillary bridges with axial and translational symmetries, where the capillary bridge height remained constant. In the second step, we have focused our studies on capillary bridges with axial symmetry (AS bridge), and we have studied the bridges rupture process. Finally, in the third step, we have studied the fluctuations, which are not predicted by the CT, in simpler systems, such as free droplets, which are not attached to walls, and droplets with axial symmetry. We have shown that the macroscopic CT is able to satisfactorily predict systems with volumes in the order of 100 cubic nanometer, in which we have been submitted our results to rigorous comparisons to the analytic CT solutions, which is able to predict the dependence of contact angle on the AS bridge rupture heights, and the volumes of droplets formed after rupture.
28

Evaluation of emulsion destabilization by light scattering applied to metalworking fluids. / Avaliação da desestabilização deemulsões por espalhamento de luz, aplicada a fluídos de corte.

Cristhiane Assenhaimer 25 August 2015 (has links)
Monitoring of emulsion properties is important in many applications, like in foods and pharmaceutical products, or in emulsion polymerization processes, since aged and broken emulsions perform worse and may affect product quality. In machining processes, special types of emulsions called metalworking fluids (MWF) are widely used, because of its combined characteristics of cooling and lubrication, increasing the productivity, enabling the use of higher cutting speeds, decreasing the amount of power consumed and increasing tool life. Even though emulsion quality monitoring is a key issue in manufacturing processes, traditional methods are far from accurate and generally fail in providing the tools for determining the optimal useful life of these emulsions, with high impact in costs. The present study is dedicated to the application of a spectroscopic sensor to monitor MWF emulsion destabilization, which is related to changes in its droplet size distribution. Rapeseed oil emulsions, artificially aged MWF and MWF in machining application were evaluated, using optical measurements and multivariate calibration by neural networks, for developing a new method for emulsion destabilization monitoring. The technique has shown good accuracy in rebuilding the droplet size distribution of emulsions for monomodal and bimodal distributions and different proportions of each droplet population, from the spectroscopic measurements, indicating the viability of this method for monitoring such emulsions. This study is part of a joint project between the University of São Paulo and the University of Bremen, within the BRAGECRIM program (Brazilian German Cooperative Research Initiative in Manufacturing) and is financially supported by FAPESP, CAPES, FINEP and CNPq (Brazil), and DFG (Germany). / Sem resumo em português.
29

Espectros de gotas e taxas de aplicação de fungicidas em diferentes horários no controle da ferrugem asiática da soja / Influence of droplets spectra and application rates of fungicides at different times of spray on asian soybean rust control

Cadore, Pedro Ceretta 03 March 2017 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Asian rust causes significant yield loss in soybean and its control is based on fungicide applications. Factors related to application technology, such as techniques adopted and climatic conditions, influence the success of disease control. The aim of this study was to evaluate the fungicide applications at different times through different droplets spectra and application rates, aiming at maximum control efficiency of Asian soybean rust. The experiment was conducted in two seasons in randomized complete block design in fatorial scheme (5 x 2 x 3) + 1 with split-plot arrangement and four replications. The factors studied were five application times (5 a.m. 9 a.m. and 1 p.m., 5 p.m., 9 p.m.), two droplets spectra (fine and medium), three application rates (60, 100 and 140 L.ha-1) and a control treatment (no application). Four applications were performed, the first three with the fungicide Trifloxystrobin + Protioconazole (60 + 70 g.a.i.ha-1) and the last with the fungicide Trifloxystrobin + Ciproconazole (75 + 32 g.a.i.ha-1). All fungicide treatments received the addition of Aureo® (0.25% v.v-1). The variables evaluated were Volumetric Medium Diameter (VMD), droplets density, leaf area covered by drops, Area Under the Rust Progression Curve (AURPC), Normalized Difference Vegetation Index (NDVI) and soybean yield. The results showed that: the fine spectrum promoted greater penetration and droplets coverage in the crop canopy; the increase in application rate increased droplets coverage, disease control, and crop yield; the application times at 9 a.m., in the first season, and at 5 p.m., in the second season, showed the best effective control of Asian soybean rust. / A ferrugem asiática causa perdas significativas no rendimento da cultura da soja e seu controle é baseado em aplicações de fungicidas. Fatores relacionados à tecnologia de aplicação, como as técnicas adotadas e as condições climáticas, influenciam no sucesso de controle da doença. O objetivo deste estudo foi avaliar aplicações de fungicidas realizadas em diferentes horários através de diferentes espectros de gotas e taxas de aplicação visando a máxima eficácia de controle da ferrugem asiática da soja. O experimento foi conduzido em duas épocas no delineamento de blocos ao acaso em esquema fatorial (5 x 2 x 3) + 1 com parcelas subdivididas e quatro repetições. Os fatores estudados foram cinco horários de aplicação (às 05:00, 09:00, 13:00, 17:00 e 21:00), dois espectros de gotas (fino e médio), três taxas de aplicação (60, 100 e 140 L.ha-1) e um tratamento de testemunha (sem aplicação). Foram realizadas quatro aplicações, sendo as três primeiras com o fungicida Trifloxistrobina + Protioconazol (60 + 70 g.i.a.ha-1) e a última com o fungicida Trifloxistrobina + Ciproconazol (75 + 32 g.i.a.ha-1). Todas as caldas receberam o adjuvante Aureo® (0,25% v.v-1). As variáveis avaliadas foram Diâmetro Mediano Volumétrico (DMV), densidade de gotas, área foliar coberta por gotas, Área Abaixo da Curva de Progresso da Ferrugem (AACPF), Índice de Vegetação por Diferença Normalizada (NDVI) e produtividade de soja. Os resultados demonstraram que: o espectro fino promoveu maior penetração e cobertura de gotas no dossel da cultura; o aumento na taxa de aplicação elevou a cobertura de gotas, o controle da doença e a produtividade da cultura; os horários de aplicação às 09:00, na primeira época de semeadura, e às 17:00, na segunda época de semeadura, proporcionaram a melhor eficácia de controle da ferrugem asiática da soja.
30

Avaliação de pontas de pulverização sob diferentes condições operacionais / Evaluation of spray nozzle by different operational conditions

Viana, Rafael Gomes 18 September 2006 (has links)
Made available in DSpace on 2015-03-26T13:39:43Z (GMT). No. of bitstreams: 1 texto completo.pdf: 440959 bytes, checksum: d22f486cf5e4f4bfebe84fc49fb6dd16 (MD5) Previous issue date: 2006-09-18 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work had the objective to evaluate different spray nozzle by different operational conditions in order to have subsidies for the correct selection of spray nozzle for pesticide application. The work consisted of two experiments. On the first, it was evaluated the deposition of drops on the soybean canopy by spray nozzle XR11002 (XR), TXA8002 (TX), TT11002 (TT) and TJ60-8002 (TJ) exposed to pressure of 827, 552 and 276 kPa. It was quantified the volume median diameter (DMV) of the drop population, density of drops (drops cm-2) and covering percentage. The drops were collected in three positions on the soybean canopy: superior third, medium and inferior of the plant by factorial scheme 4x3x3 (four spray nozzle, three pressure and three positions on the soybean canopy) in a totally occasional sketch with four repetitions. On the second experiment, the technical characteristics of spray nozzle LA-1JC and SR-1 were evaluated by different operational conditions. It was evaluated the pattern check of spray nozzle in test workbench following the pattern ISO 5682/2 on heights of 30, 40 and 50 cm, determining spray nozzle outflow, drops spectrum, left, right and total angle spray. All characteristics analyzed were submitted to pressure of 100, 200 and 300 KPa. In the experiment about the deposition of drops on the soybean canopy, it was realized that the drop population showed higher DMV on the superior third of the plant. However, the nozzle TJ provided drops with homogeneous DMV in the evaluated positions. Independent of spray nozzle utilized, the pressure of 276 KPa allowed deposition of drops with same size on the three positions. For the other pressures, it was obtained higher pressure on the superior third of the plant. The TJ nozzle provided similar covering of the aim on the three third and superior covering on the other nozzle of the medium third and inferior of the plant. The nozzles promoted higher density of drops on the superior third of the plant, decreasing in proportion to reduce the height, except TJ nozzle which showed homogeneous density in the three positions. Analyzing technical characteristics of SR-1 and LA-1JC nozzles, it was observed continuous pattern check to the LAI-JC nozzles in all pressure and SR-1 when utilized pressure of 100kPa that was indicated for stripe. SR nozzle showed discontinued pattern in the pressure of 200 and 300 kPa, which is indicated for application in total area. There was better uniformity in the distribution (lower rate of variation), with lower set at intervals on the nozzles and higher bar height. For both nozzles DMV decreased in proportion to the increase of the pressure. Independent of the work pressure utilized, LA-1JC and SR-1 nozzles provided extremely dense drops. CH is adequate to the patterns of jet plane nozzle (lower than 5) showing great homogeneity in the drops spectrum in every work pressure. LA-1JC nozzle showed higher outflow than SR1, on the pressure of 200 and 300 kPa, having no difference observed when 100 kPa pressure was utilized. The left and right angle of pulverization were symmetrical that there weren t differences between nozzle and pressure. There was increasing on the angle in proportion to the pressure improvement on the nozzle. It is indicated TJ nozzle for pesticides application in adequate climate conditions. / Objetivou-se, neste trabalho, avaliar diferentes pontas de pulverização em diferentes condições operacionais, visando fornecer subsídios para a seleção correta de pontas de pulverização para aplicação de agrotóxicos. O trabalho constou de dois experimentos. No primeiro foi avaliado a deposição de gotas no dossel da soja pelas pontas de pulverização XR11002 (XR), TXA-8002 (TX), TT11002 (TT) e TJ60-8002 (TJ), submetidas a pressões de 827, 552 e 276 kPa. Quantificou-se o diâmetro da mediana volumétrica (DMV) da população de gotas, densidade de gotas (gotas cm-2) e porcentagem de cobertura. A coleta das gotas foi realizada em três posições no dossel da soja: terço superior, médio e inferior da planta em esquema fatorial 4x3x3 (quatro pontas de pulverização, três pressões e três posições no dossel da planta) em um DBC com quatro repetições. No segundo experimento avaliou-se as características técnicas das pontas de pulverização LA-1JC e SR-1 sob diferentes condições operacionais. Avaliou-se o perfil de distribuição das pontas em bancada de ensaios padronizada seguindo a norma ISO 5682/2 em alturas de 30, 40 e 50 cm, determinou-se a vazão das pontas, o espectro de gotas, o ângulo de pulverização esquerdo, direito e total. Todas as características avaliadas foram submetidas as pressões de 100, 200 e 300 kPa. Observou-se no experimento de deposição de calda no dossel da soja, que a população de gotas apresentou maior DMV no terço superior da planta, entretanto a ponta TJ proporcionou gotas com DMV homogêneo nas posições avaliadas. Independente da ponta de pulverização utilizada, a pressão de 276 kPa permitiu deposição de gotas com tamanho uniforme nas três posições. Para as demais pressões, maior DMV foi obtido no terço superior da planta. A ponta TJ, proporcionou cobertura do alvo semelhante nos três terços e cobertura superior as demais pontas no terço médio e inferior da planta. As pontas promoveram maior densidade de gotas no terço superior da planta, decrescendo à medida que se reduz a altura, exceto para ponta TJ, que apresentou densidade de gotas homogênea nas três posições. Avaliando as características técnicas das pontas SR-1e LA-1JC, observou-se perfil de distribuição contínuo para as pontas LA1-JC em todas as pressões e da SR-1 quando utilizado a pressão de 100 kPa, sendo indicado para aplicação em faixa. A ponta SR-1 nas pressões de 200 e 300 kPa apresentou perfil descontínuo, sendo indicado para aplicação em área total. Houve melhor uniformidade de distribuição (menor coeficiente de variação), com menor espaçamento entre pontas e maior altura de barra. Para ambas as pontas, à medida que se aumentou a pressão diminuiu-se o DMV. Independente da pressão de trabalho utilizada, as pontas LA-1JC e SR-1 proporcionaram gotas extremamente grossas. O CH está adequado aos padrões para pontas de jato plano (menor que 5), apresentando boa homogeneidade no espectro de gotas em todas as pressões de trabalho. A ponta LA-1JC apresentou maior vazão em relação a ponta SR-1, nas pressões de 200 e 300 kPa, não sendo verificada diferença quando utilizada a pressão de 100 kPa. O ângulo de pulverização esquerdo e direito foram simétricos não havendo diferenças entre pontas e pressão. Houve aumento no ângulo a medida que se aumentou a pressão para ambas as pontas.

Page generated in 0.0503 seconds