• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 8
  • Tagged with
  • 24
  • 20
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Modelling and simulation of physics processes for in-beam imaging in hadrontherapy / Modélisation et simulation des processus physiques pour l’imagerie en ligne de l’hadronthérapie

Pinto, Marco 19 December 2014 (has links)
L'hadronthérapie joue un rôle de plus en plus important au sein des techniques de radiothérapie grâce aux propriétés balistiques des ions et, dans le cas de ceux plus lourds que les protons, à une augmentation de l'efficacité biologique dans la région tumorale. Ces caractéristiques permettent une meilleure conformation de la dose délivrée au volume tumoral et elles permettent en particulier de traiter des tumeurs radio-résistantes. Elles conduisent cependant à une grande sensibilité du parcours des ions aux incertitudes du traitement. C'est dans ce contexte qu'a été proposée la détection de radiations secondaires émises lors des interactions nucléaires induites par les ions incidents dans le patient. La tomographie par émission de positons et la détection des rayons gamma prompts ont notamment fait l'objet d'une recherche intense ces dernières années. Le réseau de formation européen ENTERVISION, soutenu par la communauté ENLIGHT, a été crée fin 2009 pour développer ce type d'imagerie et, plus généralement, traiter les incertitudes de traitement en hadronthérapie. Le travail présenté dans ce manuscrit et intitulé ≪ Modélisation et simulation des processus physiques pour l'imagerie en ligne de l'hadronthérapie ≫ est l'un des nombreux travaux issus de ce projet. Bien que le sujet soit particulièrement large, le fil conducteur de ce travail a été une étude systématique visant in fine une implémentation d'un dispositif d'imagerie ≪ gamma prompts ≫ utilisable à la fois en faisceau de protons et d'ions carbone / Hadrontherapy is taking an increasingly important role in radiotherapy thanks to the ballistic properties of ions and, for those heavier than protons, an enhancement in the relative biological effectiveness in the tumour region. These features allow for a higher tumour conformality possible and gives the opportunity to tackle the problem of radioresistant tumours. However, they may lead to a great sensitivity of ion range to treatment uncertainties, namely to morphological changes along their path. In view of this, the detection of secondary radiations emitted after nuclear interactions between the incoming ions and the patient have been long proposed as ion range probes and, in this regard, positron emitters and prompt gammas have been the matter of intensive research. The European training network ENTERVISION, supported by the ENLIGHT community, was created in the end of 2009 in order to develop such imaging techniques and more generally to address treatment uncertainties during hadrontherapy. The present work is one of the many resulting from this project, under the subject “Modelling and simulation of physics processes for in-beam imaging in hadrontherapy”. Despite the extensive range of the topic, the purpose was always to make a systematic study towards the clinical implementation of a prompt-gamma imaging device to be used for both proton and carbon ion treatments
12

Étude de l’émission de particules chargées secondaires dans l’optique d’un monitorage faisceau et de la dosimétrie en ligne en hadronthérapie / Study of secondary charged particles emission to monitor in-line dosimetry during hadrontherapy treatment

Henriquet, Pierre 06 July 2011 (has links)
Ce travail est consacré à l'étude de faisabilité d'une imagerie par reconstruction de vertex (IRV) pour le contrôle qualité en temps réel de la thérapie par faisceau d'ions carbone. La détection de vertex d'interactions nucléaires repose sur la détection de particules secondaires : grâce à un dispositif de détection spatiale des fragments chargés (tracker), on peut reconstruire les trajectoires des particules émergeant du patient et les extrapoler jusqu'à leur point d'origine (le vertex)... Dans le cadre de notre étude, la position du vertex est déterminée de deux manières différentes : soit en calculant l'intersection de la trajectoire d'un fragment émergent avec celle de l'ion incident (connue grâce à l'utilisation d'un hodoscope de faisceau placé en amont du patient), soit grâce à l'intersection de la trajectoire de deux fragments émergents détectés en coïncidence. Notre étude de faisabilité de la technique repose sur l'outil de simulation GEANT4. La première partie de l'étude a consisté à valider cet outil grâce à plusieurs expériences réalisées au GANIL (Caen) et au GSI (Darmstadt) avec des ions carbone de différentes énergies dans des cibles d'eau ou de PMMA Par la suite, la comparaison des deux modes de détection des particules secondaires a montré que la technique utilisant l'hodoscope est la plus performante. Enfin, après l'optimisation des principaux paramètres de cette technique, une simulation réaliste montre qu'il est possible de mesurer le parcours des ions avec une précision millimétrique à l'échelle d'une tranche en énergie voire à l'échelle d'un voxel unique / This work is devoted to the feasibility study of interaction vertex imaging (IVI) for real-time quality assurance in hadrontherapy treatments with carbon ion beams. Nuclear interaction vertex detection is based on secondary particle detection: a device allows us to spatially detect charged particles (tracker), thus we can reconstruct the trajectories of particles emerging from the patient and then extrapolate their emission point (vertex). In our study, the vertex position is determined by two ways: either by calculating the intersection of the trajectory of an emerging fragment with the trajectory of the incident ion (measured by means of a beam hodoscope upstream of the patient), or with the intersection of two emerging particles trajectories detected in coincidence. Our feasibility study of this technique relies on the GEANT4 simulation tool. The first part of the study aimed to validate this tool with experiments performed at GANIL (Caen) and GSI (Darmstadt) using carbon ion beams at various energies and in various targets (water or PMMA). Secondly, the comparison of two different technics for secondary particles detection showed that the technique using the hodoscope is the most efficient. Finally, after the parameters optimization of this technique, a realistic simulation shows that it is possible to measure ion paths within millimeter precision during each energy slices. A control of each beam spot may also be possible
13

Etude de la fragmentation lors de la réaction 12C+12C à 95 MeV/n et 400MeV/n dans le cadre de la hadronthérapie / Study of fragmentation cross-sections for 12C+12C reaction at 95 MeV/u and 400 MeV/u for hadrontherapy

Juliani, Didier 11 September 2013 (has links)
La hadronthérapie est une méthode de radiothérapie utilisant des ions (ici le carbone) comme faisceau plutôt que des rayons X plus conventionnels pour le traitement des cancers. Étant donné le parcours spécifique des ions dans la matière, ils permettent de traiter des tumeurs profondes dans des zones délicates telles que le cerveau par exemple. Ceci est complémentaire à tout ce qui existe depuis des dizaines d’années (intervention chirurgicale, rayons X, chimiothérapie). Deux futurs centres de traitement et de recherche (ARCHADE à Caen et ETOILE à Lyon) seront opérationnels en France à partir de 2018 en ce qui concerne ARCHADE afin de profiter des avancées récentes et de poursuivre les recherches sur cette méthode. La perte d’énergie des ions carbone dans la matière suit la loi de Bethe-Bloch, le maximum de dépôt d’énergie se situant dans une zone restreinte appelée « pic de Bragg ». En modulant la position et l’énergie du faisceau, il est possible d’irradier l’ensemble du volume de la tumeur. Cependant, les réactions nucléaires de l’ion carbone dans les tissus entrainent la production de fragments plus légers (H, He, Li etc.) qui déposent leur énergie au-delà du pic de Bragg. Les modèles implémentés dans les codes de simulation couramment utilisés en hadronthérapie (FLUKA, GEANT4 etc.) sont incapables de reproduire en même temps les distributions angulaires des fragments générés ainsi que les distributions en énergie. Le fait de ne pas reproduire fidèlement ce phénomène de fragmentation nuit à la précision des systèmes de planification de traitement utilisés cliniquement. En effet, une mauvaise estimation du processus de fragmentation entraine un biais dans le calcul de la dose déposée dans les cellules saines en arrière du pic de Bragg. Ainsi, afin de mieux contraindre les modèles, deux expériences de mesure de sections efficaces de fragmentation du carbone ont été menées. La première en mai 2011 avec un faisceau à 95MeV/n au GANIL à CAEN avec les collaborateurs du LPC Caen et la seconde en août 2011 avec un faisceau à 400 MeV/n au GSI à Darmstadt, avec la collaboration FIRST. L’expérience E600 étudie la fragmentation des ions du faisceau de carbone à 95 MeV/n dans différentes cibles minces (Au, C, , Ti etc.) correspondant aux différents constituants élémentaires du corps humain. Les différents fragments sont détectés à l’aide de cinq télescopes. Chacun d’eux est constitué de 3 étages (2 détecteurs silicium et un scintillateur CsI) afin de faire des mesures de perte d’énergie et d’énergie totale permettant une identification par la méthode du ΔE-E. Ces télescopes étaient disposés sur des raquettes pilotées à distance afin de pouvoir modifier leur position angulaire par rapport à la position de la cible. Ainsi, les taux de production des différents fragments permettent de remonter aux sections efficaces de fragmentation doublement différentielles (en énergie et en angle). [...] / The hadrontherapy is a radiotherapy method using ions (carbon ions here) instead of the more conventional X-rays for cancer treatment. Deep radioresistant tumour areas, as brain carcinoma for example, can be treated thanks to the specific dosedeposition at the end of the ion path. This is an additional method to older classic ones (surgery, X-rays, chemotherapy). Two hadrontherapy centres for treatment and research are planned in France from 2018 (ARCHADE) in order to benefit from the newest progress and to keep improving this method. Carbon ions energy loss in the matter follows the Bethe-Bloch law. The maximum of energy depth is located in a limited area called “Bragg peak”. By adjusting the beam position and energy, the whole volume of the tumor can be irradiated. Nevertheless, nuclear reactions of carbon ion in tissues generate the production of lighter fragments (H, He, Li etc.) that deposit their energy beyond the Bragg peak. Models implemented in hadrontherapy simulation codes (FLUKA, GEANT4 etc.) cannot reproduce angular distributions of the lighter fragments and energy distributions at the same time. These poor estimations affect the treatment planning systems accuracy that are clinically used.Indeed, a bad estimation of fragmentation process induces a bias in the dose calculation concerning healthy cells beyond the Bragg peak. In order to better constraint models, two experiments based on fragmentation cross-sections measurements have been performed. The first one in may 2011 with a beam at 95 MeV/u (GANIL) in collaboration with the LPC Caen and the second one in august 2011 with a beam at 400 MeV/u (GSI) with the FIRST collaboration. E600 experiment is devoted to the study of carbon ions fragmentation at 95 MeV/u in several thin targets (Au, C, , Ti etc.) corresponding to the basic building blocks of human body. Five telescopes are designed for the fragments detection. Each one is a three-stage detector (2 silicon detectors and one CsI scintillator) that allows energy loss and total energy measurements for the ΔE-E identification method.Telescopes were disposed two by two in the reaction chamber with a remote control of the angular position. From the production rate measurements, the double differential fragmentation cross-sections (energy and angle) can be computed.From the experimental data for + reaction at 95 MeV/u on a 250 μm thick carbon target, all cross-sections were deduced.FIRST experiment uses a very different set-up. It is composed of: a beam monitoring, a vertex detector (CMOS), a calorimeter(KENTROS), a magnet (ALADIN), MUSIC (3 ionization chambers and 4 proportional counters) and a TOF-wall. Generated particles trajectory is reconstructed thanks to the vertex detector + TOF-wall for all fragments emitted with an angle lower than 5° and thanks to the vertex detector + KENTROS for higher angles. In the first case, the ALADIN magnet deflects the trajectory of the particles (MUSIC detector ran out). One 8 mm thick target has been used here. Preliminary results concerning production rates of the different charges, angular distributions and reconstruction efficiencies have been obtained. Heavier fragments mass identification is quite difficult because of the non-working MUSIC detector; it degrades the fragments momentumaccuracy.[...]
14

Etude de la mesure en ligne de l'activité β+ induite lors des traitements d'hadronthérapie, en vue de leur contrôle balistique / Study of the online measurement of the β+ activity induced during hadrontherapy treatments, with a view to their ballistic control

Lestand, Loïc 24 September 2012 (has links)
Le cancer est aujourd’hui la première cause de mortalité en France, devant les pathologies cardio-vasculaires, si bien qu’il constitue un enjeu de santé publique majeur. Parmi les alternatives thérapeutiques actuellement pratiquées en milieu clinique, on compte l’ensemble des techniques de radiothérapie externe. L’hadronthérapie est une technique émergente de radiothérapie, caractérisée par des propriétés balistiques et biologiques compatibles avec la définition de protocoles cliniques et thérapeutiques hautement conformationnels. La précision balistique, c’est à dire la capacité à irradier un volume cible avec précision repose sur un ensemble de paramètres pouvant être entachés d’incertitudes et dont la quantification n’est pas toujours possible. Aussi, la mise en place de procédures de contrôles de l’irradiation devient indispensable à l’utilisation de cette technique de manière raisonnée et pertinente. Le contrôle balistique peut être réalisé par une technique d’imagerie biomédicale, la Tomographie par Emission de Positons (TEP), qui permet de mesurer la distribution de la radioactivité β+ induite par le faisceau primaire. Les premiers résultats obtenus, tant sur le plan de la simulation que sur celui de l’instrumentation, ont permis de poser les jalons d’une méthodologie de mesure et d’analyse des données compatibles avec cette problématique de mesure en ligne. Des mesures réalisées auprès du centre protonthérapie d’Orsay, un des deux centres d’hadronthérapie français, et du grand accélérateur national d’ions lourds (GANIL) de Caen, ont permis de fournir une preuve de concept et d’initier un chantier visant à concevoir un détecteur suffisamment grand, qui sera exploité dans le cadre de protocoles cliniques déterminés. / Cancer remains the main cause of death in France which constitutes a major public heathcare issue. Among all therapeutic alternatives currently used in clinical routine there are all external radiation therapy technics. A new type of highly conformational radiation therapy, called hadrontherapy has been developped over almost 50 years. Balistic accuracy relies on a set of parameters which can be affected by different sources of uncertainties that remain hardly predictable. Therefore, this technic requires the definition of quality assurance (QA) procedures to prevent any deleterious health consequences for the patient. Such QA procedures can be achieved by measuring the induced β+ activity by means of Positron Emission Tomography. The first results obtained by simulations and through different experiments performed on proton and carbon ion beams have lead to define a methodology of data acquisition and analysis compatible with in-beam QA of hadrontherapy treatments. Moreover, experiment performed at GANIL (carbon beam) and CPO Orsay (proton beam) have helped to initiate the construction of a larger detector which could be used within different clinical routine treatments.
15

Construction et premières caractérisations d'un détecteur dédié à la mesure de l'activité β + induite lors des traitements d'hadronthérapie, en vue de leur contrôle balistique / Construction and first characterisations of an in-beam PET detector for the ballistic control in hadrontherapy

Rozes, Arnaud 16 September 2016 (has links)
L’hadronthérapie est une technique de traitement des cancers basée sur l’utilisation de faisceaux d’ions (principalement des protons et des ions 12 C). L’intérêt des ions repose sur deux propriétés fondamentales. La première est d’ordre balistique. Le mode d’interaction des ions avec la matière, caractérisé par le phénomène de pic de Bragg, se traduit par une faible dispersion spatiale de l’énergie déposée dans les tissus. Ceci permet un très bon niveau de conformation au volume tumoral. La seconde est d’ordre biologique, notamment pour les ions 12 C qui présentent une cytotoxicité élevée, utile pour le traitement de tumeurs radiorésistantes. Pour pouvoir utiliser toutes les possibilités offertes par les faisceaux d’ions, de nouveaux outils de contrôle qualité doivent être mis au point. L’utilisation des particules secondaires générées lors de l’irradiation est la voie choisie pour vérifier la conformité des traitements d’hadronthérapie. Certaines de ces particules secondaires présentent une distribution d’activité fortement corrélée au dépôt de dose. C’est le cas des noyaux émetteurs β + dont la détection est basée sur le principe de la tomographie par émission de positons (TEP). La mesure de la distribution en radionucléides émetteurs β + produits par fragmentation du projectile et/ou de la cible permet de détecter des erreurs sur le parcours des ions. Nous présentons ici les travaux de construction d’un démonstrateur appelé DPGA et la mise au point des outils qui lui sont associés pour réaliser la vérification du parcours des ions à partir de la mesure de l’activité β + induite lors des traitements d’hadronthérapie. Le but du DPGA est de pouvoir évaluer certains choix matériels et logiciels avec comme objectif de pouvoir, à terme, effectuer la mesure du parcours des ions en ligne pendant l’irradiation. / Hadrontherapy is a radiation therapy for cancer based on ion beams (mainly protons or carbon ions). This type of treatment offers two advantages compared with conventional x-ray therapy. First the ions penetrate the tissues with little diffusion and the energy transfer is maximum just before stopping (Bragg peak). Then the ions offer a superior dose conformity with tumor volume. Moreover carbon ions offer a higher biological effectiveness useful for radioresistant tumors treatments. To fully exploit the ion beams properties, new quality assurance procedures have to be defined. These controls can be achieved by measuring the β + activation which is induced during the treatments by means of Positon Emission Tomography (PET). PET can be applied for ion range verification because of the correlation between the dose distribution and the spatial distribution of secondary β + activity. We present in this thesis the building of a demonstrator called DPGA and the design of several of its tools dedicated for ion range verification. The aim of the DPGA is to trial hardware and software solutions for an on-line measurement during irradiation.
16

Mesure de la dose physique par lms radiochromiques et simulation Monte Carlo pour l'hadronthérapie / Dose measurement using radiochromic lms and Monte Carlo simulation for hadrontherapy

Zahra, Nabil 25 June 2010 (has links)
En raison des forts gradients de dose générés par les interactions des particules avec la matière, les traitements par hadronthérapie nécessitent un contrôle très précis de la dose délivrée au patient. Les codes Monte Carlo représentent des outils indispensables dans la validation des systèmes de planification de traitement utilisé en clinique. Nous nous intéressons dans cette thèse au calcul de la dose physique à l'aide des simulations Monte Carlo Geant4/Gate. Nous étudions l'ajustement de plusieurs paramètres qui peuvent influencer la précision du calcul de dose requise en clinique (2%, 2mm) pour un faisceau d'ions carbone de 300 MeV/u dans l'eau. Ces paramètres sont : le seuil de production des particules secondaires et la taille maximale d'un segment de la trace de particule. Les critères de tolérance sur la valeur et la localisation de la dose sont fixés de manière à avoir le meilleur compromis en termes de distribution spatiale et de temps de calcul. Nous proposons ici des paramètres permettant d'atteindre ces critères de précision. Dans la deuxième partie du travail, nous étudions la réponse des films radiochromiques MDv2-55 pour le contrôle qualité des faisceaux d'ions carbone et protons. Nous avons en particulier observé et étudié l'effet de saturation de ces films dosimétriques pour les irradiations à TEL élevés (≥ 20 KeV/µm) dans des milieux homogènes et hétérogènes. Cet effet est dû à la forte densité d'ionisation autour de la trace de particule. Nous avons proposé et développé un modèle appelé « RADIS RAdiochromic films Dosimetry for Ions using Simulations » qui permet de prédire la réponse de ces films avec la prise en compte de cet effet de saturation. Ce modèle est basé sur la réponse des films en photons et la saturation des films à des dépôts d'énergies linéïques élevés calculée par Monte Carlo. Plusieurs types de faisceaux ont été étudiés : ions carbone, protons et photons à différentes énergies. Ces expérimentations ont été menées au Grand Accélérateur National d'Ions Lourds (GANIL), au Centre de protonthérapie d'Orsay (CPO), au Centre A. Lacassagne (CAL) et au Centre Léon Bérard (CLB). A l'aide du modèle, nous pouvons ainsi reproduire la densité optique des films le long du profil de Bragg pour tous les faisceaux avec une précision meilleure que 2%. / Because of the increase in dose at the end of the range of ions, dose delivery during patient treatment with hadrontherapy should be controlled with high precision. Monte Carlo codes are now considered mandatory for validation of clinical treatment planing and as a new tool for dosimetry of ion beams. In this work, we aimed to calculate the absorbed dose using Monte Carlo simulation Geant4/Gate. The ejffect on the dose calculation accuracy of dierent Geant4 parameters has been studied for mono-energetic carbon ion beams of 300 MeV/u in water. The parameters are : the production threshold of secandary particules and the maximum step limiter of the particle track. Tolerated criterion were choosen to meet the precision required in radiotherapy (2%, 2mm) and to obtain the best compromise on dose distribution and computational time.We propose here the values of parameters in order to satisfy the precision required. In the second part of this work, we will study the response of radiochromic lms MD-v2-55 for quality control in proton and carbon ion beams. We have particularly observed and studie the quenching effect of dosimetric lms for high LET (20 KeV/m) irradiations in homogeneous and heterogeneous medium. This eject is due to the high ionization density around the track of the particule. We have developped a method to predict the response of radiochromic lms taking into account the saturation effect. This model is called the RADIS model forRAdiochromic films. Dosimetry for Ions using Simulations". It is based on the response of lms under photon irradiations and the saturation of lms due to high linear energy deposit calculated by Monte Carlo. Four beams were used in this study and aimed to validate the model for hadrontherapy applications : carbon ions, protons and photons at different energies. Experiments were performed at Grand Accélérateur National d'Ions Lourds (GANIL), Proton therpay center of Orsay (CPO), A. Lacassagne proton center (CAL) and Leon Berard cancer center (CLB). The model showed very good agreement between the measured and calculated optical density with an error less than 2%.
17

Planification inverse de la dose en hadronthérapie : prise en compte de la qualité du rayonnement pour une optimisation de la dose biologique / Inverse dose planning in hadrontherapy : taking into account the beam quality for an optimization of the biological dose

Smekens, François 02 December 2011 (has links)
L'hadronthérapie est une modalité d'irradiation récente particulièrement attractive. Les ions, par leur profil caractéristique de dépôt de dose dans la matière et leur efficacité biologique accrue, sont des particules parfaitement adaptées pour le traitement du cancer. C’est une modalité émergente et les travaux de recherche et de développement qui en font l'objet se poursuivent de manière soutenue. Cependant, il n'existe à ce jour aucun outil permettant de quantifier pour le patient le gain clinique associé aux améliorations proposées, comme l’apport d’une gantry par exemple. Nous proposons dans ce travail de concevoir un module de planification inverse du traitement pour un but prospectif. Détachée des contraintes usuelles de précision et de temps de calcul, notre méthode d'optimisation se base sur un algorithme génétique afin d'approcher d'une solution globale vis-à-vis d'un grand nombre de paramètres balistiques (champs d’irradiation libres) et en associant les diverses régions d'intérêt dosimétrique. La stratégie d'optimisation retenue est progressivement complexifiée afin de prendre en compte de manière efficace les différents enjeux de la planification. La robustesse du plan vis-à-vis des incertitudes inhérentes au traitement, primordiale en hadronthérapie, est évaluée. Dans toutes les situations testées, il apparaît que l'inclusion dans l'optimisation de paramètres habituellement fixés manuellement permet une amélioration de la qualité de traitement. Nous proposons au terme de cette étude un outil prospectif d'optimisation au réglage simple et capable de mener des études comparées sur la pertinence de nouvelles modalités d’irradiation. / Hadrontherapy is a recent and particularly attractive modality. Characterized by a specific dose deposition profile in matter and by a high biological effectiveness, ions are found to be very well-suited for cancer treatment. As an emergent modality, the research in hadrontherapy is extremely active and promises many improvements for the future. However, there is no tool to date to quantify the clinical benefit for the patient related to the proposed improvements, the use of a gantry for example. In this work, we propose to use the treatment planning system, usually dedicated to clinical practice, in a prospective purpose. Suppressing the classical constraints of precision and time, our optimization method is based on a genetic algorithm designed to approach a global solution including a high number of balistic parameters (free irradiation fields) for all regions of dosimetric interest. The optimization strategy is progressively complicated in order to efficientely take into account the main issues of the inverse planning problem. The robustness of plans towards the uncertainties related to the application of the treatment, essential in hadrontherapy, is evaluated. The results show that the inclusion, in the optimization, of parameters usually fixed by the human planner leads systematically to an improved treatment quality. The final product of this work is a prospective optimization tool characterized by an easy set-up system and the ability to perform comparative studies on the relevance of new irradiation modalities.
18

Etude de conception d’ASICs de lecture et d’étiquetage en temps associés à des photomultiplicateurs pour un hodoscope de faisceau en hadronthérapie / Design study of readout and time-stamp ASICs associated to photomultipliers for a beam hodoscope in hadrontherapy

Deng, Shi-Ming 27 November 2012 (has links)
Pour développer un hodoscope de faisceau en hadronthérapie, capable de localiser les ions dans le plan transverse et de les étiqueter en temps avec une précision de 1 nc et un taux de comptage de 100 000 000 HZ, nous avons mené des études de conception d'ASICs (Aplication Specific Integrated Circuits) de lecture à associer à des photomultiplicateurs multi-anode. Un front-end ASIC 16 voies en technologieAMS BiCMOS 0,35 µm a été conçu, fabriqué et testé. Il intégre, sur chaque voie, un convoyeur de courant avec deux sorties en étage d'entrée, et deux étages de sortie séparés qui sont respectivement un comparateur en courant et un préamplificateur de charge. Il réalise à la fois la détection d'évènements et la quantification de signal détecté. L'étude de conception a apporté des performances optimisées sur la dynamique d'entrée, la consommation d'énergie, la rapidité, le bruit. Le fonctionnement du circuit de lecture incorporé dans un système de test a aussi été vérifié par une expérimentation en faisceau. D'autre part, nous avons conçu un ASIC d'étiquetage en temps utilisant la technologie AMS CMOS 0,35 µm. Il est à base d'une boucle à verrouillage de délai analogique avec la mise en oeuvre de la méthode de mesure du "temps de vol", et dispose d'un mode d'entrée d'horloge LVDS (Low Voltage Differential Singaling) et d'une sortie de 5 bits en code Gray. Il fonctionne avec une résolution temporelle de 200 ps selon les résultats de tests. Ces études nous ont permis de lancer un nouveau projet de conception : intégrer sur une puce les fonctions électroniques que nous avons réalisées et validées. / To develop a beam hodoscope in hadrontherapy, able to localize the beam position and to get a time tagging with a accuracy of ~ 1ns at a count rate of 100 000 000 HZ, we have studied and designed read-out ASICs' (Application Specific Intergrated Circuits) to be associated with multi-anode photomultiplier. One of 16-channel front-end ASIC in 0,35 µm AMS BICMOS process ahs been designed, fabraicated and tested. Each channel consists to a current coveyor (with two current outputs) as an input stage, and two separat output stages wich are a current comparator and a charge-sensitive amplifier (CSA) respectively. It performs both signal-event detection and signal charge quantification. The design work includes optimization of circuit performances such as input dynamic range, power dissipation; speed and noise. The circuit has also ben incorporated in a test system and its opration has been verified by beam experimentation. On the other hand, we have also designed another ASIC in a 0.35 µm AMS CMOS process. Itn is based on an analog DLL (Delay Locked Loop) with implementation of the TOF (Time Of Flight) measuring method. It has a LVDS (Low Voltage Differential Signaling) clock input mode and a 5-bit Gray-code output. It operates with 200-ps timing rsolution according to test results. These studies have led us to launch a new design project: integrating the studied and validated electronic functions on a single chip.
19

Interactions of slow multiply charged ions with large, free radiosensitizing metallic nanoparticles / Interaction d'ions multichargés lents avec des nanoparticules métalliques radiosensibilisantes

Mika, Arkadiusz 19 December 2017 (has links)
Cette thèse est consacrée à l'étude de l'interaction d'ions multichargés avec des particules métalliques de taille nanométrique. Ce travail a eu pour but d'étudier les processus fondamentaux ainsi que d'éclairer leur rôle comme radio-sensibilisants dans le traitement de cancer par hadronthérapie. Le nouveau dispositif développé dans ce cadre consiste en une source d'agrégats de type magnétron, d'une chambre de dépôt afin de permettre la caractérisation de la taille des nanoparticules neutres par analyse microscopique, et d'un spectromètre de masse par temps de vol capable de détecter des systèmes positivement chargés jusqu'à une masse de 50 000 ua. Les études de collisions ont été réalisées avec des agrégats de Bi (2 nm ; 200 atomes) et de Ag (6 nm ; 5000 atomes). Dans le deux cas, le processus de capture multiélectronique crée un système multichargé. Dans le cas du Bi, une grande partie fragmente par la fission asymétrique émettant des petits fragments. Dans le cas des particules plus grandes (Ag), les systèmes multichargés ne fragmentent pas, par contre des petits fragments sont aussi observés mais ils sont le produit de la pulvérisation de la nano-surface lors de collisions pénétrantes. En perspective, des expériences seront réalisées avec des nanoparticules métalliques fonctionnalisées ainsi que le comptage des électrons émis lors de la collision. / This thesis presents a study of the interaction of multiply charged ions with metallic nano-sized particles both in the context of fundamental processes and possible applications as radiosensitizers in nanoparticle-enhanced hadrontherapy. For this purpose a new experimental set-up has been constructed based on a magnetron-discharge cluster source, a deposition chamber for analyzing the size of neutral nanoparticles with AFM and TEM techniques and a time-of-flight mass spectrometer able to detect positively charged particles with masses up to 50 000 amu. Collision studies were performed with Bi clusters of 2nm in diameter, containing 200 atoms, as well as Ag nanoparticles (6 nm, 5000 atoms). In both cases multi-electron capture leads to the formation of multiply charged systems. In the Bi case a large fraction fragments by asymmetric fission emitting small singly charged fragments. In the case of large Ag nanoparticles multiply charged systems are stable. However, small size fragments are formed due to sputtering of the nano-surface in penetrating collisions. Future experiments will be performed with functionalized metal nanoparticles, aiming to count the number of electrons emitted after ion collisions.
20

Mise en oeuvre d’un démonstrateur de caméra Compton pour l’imagerie en médecine nucléaire et pour le contrôle en temps réel de l’hadronthérapie à l’aide des rayonnements gamma prompts / Development of a time-of-flight Compton camera prototype for online control of ion therapy and medical imaging

Ley, Jean-Luc 14 December 2015 (has links)
L'hadronthérapie est l'une des modalités disponibles pour traiter le cancer. Cette modalité utilise des ions légers (protons, ions carbone) pour détruire les cellules cancéreuses. De telles particules ont une précision balistique de par leur trajectoire quasi-rectiligne, leur parcours fini et le profil de dose maximum en fin de parcours, ce qui permet, par rapport à la radiothérapie conventionnelle, d'épargner les tissus sains situés à côté, en aval et en amont de la tumeur. L'un des enjeux de l'assurance qualité de cette modalité est le contrôle du positionnement de la dose déposée par les ions dans le patient. Une possibilité pour effectuer ce contrôle est d'observer les gammas prompts émis lors des réactions nucléaires induites le long du parcours des ions dans le patient. Un prototype de caméra Compton, permettant théoriquement de maximiser l'efficacité de détection des gammas prompts, est actuellement développé dans une collaboration régionale. Mon travail de thèse s'est axé autour de cette caméra et plus particulièrement sur les points suivants : i) étudier par les simulations Monte Carlo le fonctionnement du prototype en cours de construction, notamment en regard des taux de comptage attendus sur les différents types d'accélérateurs en hadronthérapie, ii) mener des études de simulation sur l'utilisation de cette caméra en imagerie clinique, iii) caractériser les détecteurs silicium du diffuseur, iv) confronter les simulations entreprises sur la réponse de la caméra avec des mesures sur faisceau à l'aide d'un démonstrateur. Il résulte que le prototype de caméra Compton développé rend possible un contrôle de la localisation du dépôt de dose en protonthérapie à l'échelle d'un spot, à condition que l'intensité clinique du faisceau de protons soit diminuée d'un facteur 200 (intensité de 108 protons/s). Une application de la caméra Compton en médecine nucléaire semble réalisable avec l'utilisation de radioisotopes d'énergie supérieure à 300 keV. Ces premiers résultats doivent être confirmés par des simulations plus réalistes (cibles de PMMA homogènes et hétérogènes). Des tests avec l'intégration progressive de tous les éléments de la caméra vont avoir lieu courant 2016 / Hadrontherapy is one of the modalities available for treating cancer. This modality uses light ions (protons, carbon ions) to destroy cancer cells. Such particles have a ballistic accuracy thanks to their quasi-rectilinear trajectory, their path and the finished profile maximum dose in the end. Compared to conventional radiotherapy, this allows to spare the healthy tissue located adjacent downstream and upstream of the tumor. One of this modality’s quality assurance challenges is to control the positioning of the dose deposited by ions in the patient. One possibility to perform this control is to detect the prompt gammas emitted during nuclear reactions induced along the ion path in the patient. A Compton camera prototype, theoretically allowing to maximize the detection efficiency of the prompt gammas, is being developed under a regional collaboration. This camera was the main focus of my thesis, and particularly the following points : i) studying, throughout Monte Carlo simulations, the operation of the prototype in construction, particularly with respect to the expected counting rates on the different types of accelerators in hadrontherapy ii) conducting simulation studies on the use of this camera in clinical imaging, iii) characterising the silicon detectors (scatterer) iv) confronting Geant4 simulations on the camera’s response with measurements on the beam with the help of a demonstrator. As a result, the Compton camera prototype developed makes a control of the localization of the dose deposition in proton therapy to the scale of a spot possible, provided that the intensity of the clinical proton beam is reduced by a factor 200 (intensity of 108 protons / s). An application of the Compton camera in nuclear medicine seems to be attainable with the use of radioisotopes of an energy greater than 300 keV. These initial results must be confirmed by more realistic simulations (homogeneous and heterogeneous PMMA targets). Tests with the progressive integration of all camera elements will take place during 2016

Page generated in 0.0704 seconds