• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 451
  • 16
  • 14
  • 14
  • 13
  • 13
  • 12
  • 6
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 488
  • 123
  • 86
  • 84
  • 84
  • 78
  • 74
  • 70
  • 58
  • 54
  • 51
  • 51
  • 49
  • 46
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Aplicação do cadastro técnico visando a avaliação de inundações urbanas

Oliveira, Tadeu de Souza January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil / Made available in DSpace on 2013-06-25T22:36:27Z (GMT). No. of bitstreams: 1 308131.pdf: 11506920 bytes, checksum: 560ee7ba1d361cddde7dde0842c83929 (MD5) / Em Santa Catarina, assim como em todo o país, e mesmo a nível mundial tornou-se comum a ocorrência de inundações urbanas, estas de difícil controle e de consideráveis prejuízos materiais, danos ao meio ambiente e até com perdas de vidas humanas. Diante de milhares de pessoas que sofrem de forma recorrente com os problemas de inundações a cada período de chuvas, a gestão pública municipal e departamentos responsáveis pelos recursos hídricos têm uma missão desafiadora em apontar proposições para solução e melhorias do sistema de drenagem urbana para o município. O objetivo desta pesquisa é aplicar o cadastro técnico na avaliação e acompanhamento da expansão urbana, sua correlação com a drenagem urbana e ocorrências de inundações bruscas na bacia hidrográfica do Rio Criciúma. Para tal propósito, a metodologia utilizada, parte do método de caracterização e levantamento dos dados, método de análise e método de avaliação. Entre os resultados encontrados referentes a bacia hidrográfica do Rio Criciúma consta para cada resultado a análise e avaliação, assim é apresentada no capítulo 4, a Caracterização da evolução histórica da ocupação urbana, onde estão as análises dos Planos Diretores de 1957, 1973, 1984 e 1999, bem como, o avanço da expansão urbana e avaliação dos vôos fotogramétricos de 1956, 1978 e 2006. No capítulo 5 é apresentada a caracterização hidrológica e física, apresentando o levantamento de dados pluviométricos e equação de chuvas intensas, a configuração da bacia hidrográfica, a caracterização morfométrica e hidrograma unitário; no capítulo 6 é apresentada a mensuração do sistema de drenagem, onde consta o cadastro da macro drenagem, da rede hidrográfica, do Rio Criciúma, da micro drenagem, da produção de sedimentos e dos esgotos sanitários no sistema de drenagem; no capítulo 7 é apresentada a caracterização e quantificação da impermeabilização, onde consta a impermeabilização das vias públicas, dos lotes por pavimentação interna, das edificações, o solo exposto, do solo com vegetação, das área de rios e alagados, coeficientes médio e máximo de escoamento superficial e cálculos Curver Number - CN. Na ocupação do subsolo está a determinação do grupo hidrológico do solo e a geologia da bacia; no capítulo 8 é apresentada as discussões, onde fica evidenciado a avaliação dos resultados do grupo hidrológico C e D, a avaliação de um modelo de solução para reduzir o volume de água excedente dentro da sub bacia analisada, os dispositivos de retardo nos lotes, os dispositivos de retardo em áreas públicas e APP´s, as diretrizes básicas para implantação de políticas públicas. No capítulo 9, conclui-se que, as soluções técnicas e as políticas públicas adotadas no período estudado não foram satisfatórias, resultando em acúmulos de problemas ambientais e desastres naturais, principalmente as inundações bruscas urbanas; o município possui material cartográfico que oferece condições para elaboração de projetos bem estruturados, necessitando melhorar a qualidade e precisão da altimetria e também que a aplicação do cadastro técnico correlacionado à estudos hidrológicos e a aplicação conjunta de hidráulica produzem resultados seguros e portanto confiáveis para a solução dos problemas estudados. / In Santa Catarina, as well as throughout the country, and even the world has become a common occurrence of urban flooding, they are difficult to control and considerable material damage, environmental damage and even loss of life. Faced with thousands of people suffering from a recurring basis with the problems of floods every rainy season, the public administration and municipal department responsible for water resources have a challenging mission to point out solutions and proposals for improvements to the urban drainage system for the city . The aim of this search is to apply the technical cadastre evaluation and monitoring of urban sprawl, its correlation with the urban drainage and occurrences of flash floods in the river basin Criciúma. For this purpose, the methodology used part of the method for characterization and data collection, analysis method and evaluation method. Among the findings related to river basin Criciúma listed for each outcome analysis and evaluation process, is presented in Chapter 4, the characterization of the historical evolution of urban occupation, where are the analysis of Master Plans 1957, 1973, 1984 and 1999, and the Advancement of urban expansion and evaluation of photogrammetric flights, 1956, 1978 and 2006. Chapter 5 presents the hydrological and physical characterization, presenting the survey data and equation of rainfall heavy rains, the configuration of the river basin, the unit hydrograph and morphometric characterization, in Chapter 6 presents the measurement of the drainage system, which consists the Register of macro drainage, river system, the Rio Criciúma, the Register of micro drainage, sediment production and sanitary sewers in the drainage system, in Chapter 7 presents the characterization and quantification of sealing, which sets forth the waterproofing public roads, by paving the lots internal to buildings, the soil above the soil with vegetation, rivers and wetlands area, average and maximum coefficients of runoff and calculations Curver Number - CN, in the occupation of the basement is the determination hydrologic soil group and the geology of the basin, is presented in chapter 8 the discussions, which evidenced the Evaluation of the results of hydrologic group C and D, Evaluation of a model solution to reduce the volume of excess water within the sub basin analyzed the devices in lots delay, the delay devices in public areas and APP, the Basic Guidelines for implementation of public policies and GUIDELINES. In chapter 9, it is concluded that the technical solutions and policies adopted during the study period were not satisfactory, resulting in accumulation of environmental problems and natural disasters, especially urban flash floods, the city has to offer cartographic material conditions for the preparation project and structured, needing to improve the quality and accuracy of altimetry and also that the application of technical cadastre correlated with hydrological studies and joint implementation of hydraulics produce reliable results and therefore trusted to solve the problems studied.
262

Avaliação quali-quantitativa de uma vala de infiltração pluvial em termos de retenção de contaminantes: Estudo de caso: Distrito do Campeche - Florianópolis-Santa Catarina

Pacheco, Elisa Ferreira January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2015. / Made available in DSpace on 2016-10-19T12:38:39Z (GMT). No. of bitstreams: 1 338947.pdf: 5597103 bytes, checksum: 116ff6b00bbc8e5f5b72e7db1a1c8048 (MD5) Previous issue date: 2015 / As estruturas de infiltração pluvial visam o controle do escoamento superficial e da poluição difusa. No Brasil existe uma lacuna no sentido de integrar os impactos no ambiente subterrâneo com o estudo da drenagem urbana no que se refere tanto aos volumes infiltrados, qualidade do solo e quanto à qualidade das águas do escoamento superficial. Neste contexto esta dissertação visa avaliar o desempenho quali-quantitativo de uma vala de infiltração pluvial, instalada no Município de Florianópolis-SC, por intermédio da análise do comportamento hidráulico da estrutura e da caracterização quali-quantitativa do escoamento superficial. Este projeto foi realizado em acordo de cooperação com a prefeitura de Florianópolis-SC, implementando-se um laboratório de campo em escala real no Distrito do Campeche, para auxiliar a Prefeitura no refinamento de seus sistemas infiltração pluvial, adotados. A avaliação da estrutura foi composta pela instrumentalização e monitoramento quali-quantitativo da água do escoamento pluvial, para os seguintes parâmetros: condutividade, pH, turbidez , sólidos totais, sólidos dissolvidos, sólidos suspensos, demanda química de oxigênio, Carbono orgânico total (COT), nutrientes (nitrito, fósforo total), metais pesados (Cd, Cu, Pb, Zn, Cr, Fe e Mn). Para as amostras de solo foram realizadas às análises de granulometria, Capacidade de Troca de Cátions (CTC), pH em H20 e em KCl, teor de matéria orgânica, teor de Argila Dispersa em Água, e teor total dos metais cádmio, chumbo, cobre, cromo, manganês, níquel e zinco. No controle do escoamento superficial a vala apresentou um ótimo desempenho hidráulico como técnica compensatória de Infiltração. Na caracterização qualitativa do solo este apresentou valores acima do valor de referência de qualidade, para todos os metais pesados, os valores de pH foram atípicos em consequência dos altos teores de matéria orgânica. Os valores turbidez, Cd, Pb e Cr na água do escoamento superficial ficaram acima do valor limite estabelecidos pelo CONAMA 357. Na Análise dos Componentes Principais da qualidade do escoamento superficial na ACP1 foi identificado o fenômeno de acumulo de sedimentos nos período de estiagem, sendo a deposição de sólidos diretamente proporcional ao volume de escoamento na entrada da vala de infiltração. E uma segunda ACP2 foi caracterizada pela correlação da turbidez com matéria orgânica. Assim, a vala funciona como fonte de contaminantes para o ambiente subterrâneo devido ao tipo de solo arenoso e a alta concentração de contaminantes na água do escoamento superficial.<br> / Abstract : The rain infiltration structures seek to control superficial runoff and diffuse pollution. In Brazil, there is a gap to integrate the impacts on underground environment with the study of urban drainage in relation to both infiltrated volumes, soil quality and the quality of the water runoff. In this context, this dissertation aims to assess the qualitative and quantitative performance of a rainwater infiltration trench, located in the municipality of Florianopolis-SC, through the hydraulic behavior analysis of the structure and qualitative and quantitative characterization of surface runoff. This project was conducted in cooperation agreement with the Municipality of Florianópolis, SC, implementing a full-scale field laboratory in the District of Campeche, to assist the City Hall in the refinement of their rainwater infiltration systems adopted.The evaluation of the structure was composed by instrumentation and qualitative and quantitative monitoring of water from runoff, for the following parameters: conductivity, pH, turbidity, total solids, dissolved solids, suspended solids, chemical oxygen demand, total organic carbon (TOC) , nutrients (nitrite, total phosphorus), heavy metals (cobalt, chromium, cadmium, copper, lead, nickel, zinc, manganese and iron).For soil samples, it was conducted particle size analysis, Cation Exchange Capacity (CEC), pH in water (H20) and potassium chloride (KCl), organic matter content, dispersed clay content in water, and the total content of the following metals, cadmium, lead, copper, chromium, manganese, nickel and zinc. In controlling runoff, the drainage trench had a great hydraulic performance as a compensatory technique of infiltration. In the qualitative characterization of soil, it showed values above the quality reference value for all heavy metals, and pH values were atypical because of high levels of organic matter. The turbidity values, Cd, Pb and Cr in the water runoff were above the limit set by CONAMA 357. Analysis of the principal components of quality of runoff in ACP1 has identified the phenomenon of accumulation of sediments in the dry season, and the deposition of solids directly proportional to the volume flow at the entrance of the infiltration trench. In addition, the second ACP2 was characterized by correlation of the turbidity with organic matter. Thus, the infiltration trench functions as a source of contaminants to the subterranean environment due to the sandy soil type and the high concentration of contaminants in the water runoff.
263

A paisagem de rios urbanos

Porath, Soraia Loechelt January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Arquitetura e Urbanismo / Made available in DSpace on 2012-10-22T05:43:58Z (GMT). No. of bitstreams: 1 201715.pdf: 10941945 bytes, checksum: df26ca5d089290baa18520b44370adab (MD5) / Os rios têm sido uma presença constante na formação e crescimento das cidades. Desde os primórdios das civilizações, por uma questão de sobrevivência e utilidade, servem como fonte de recursos e meio de circulação. Porém, os rios urbanos são mal compreendidos. São entendidos como um limite ao crescimento das cidades, um obstáculo a ser transposto, e desta forma, não recebem tratamento adequado. Vistos como um problema de drenagem urbana, localizados em fundos de lote e tratados como local de despejos, os rios não vêm sendo considerados como elementos enriquecedores na construção da paisagem urbana. Sob o aspecto físico e da forma urbana, os rios são fortes elementos da paisagem. Eles estruturam o tecido urbano que lhes é próximo, tornando-se muitas vezes eixos de desenvolvimento do desenho da cidade. Eles delimitam a configuração urbana e, em alguns casos, servem como divisa de municípios. O desenho urbano ocasiona as transformações na paisagem, na morfologia urbana e nas áreas adjacentes aos rios. Para compreendermos a dinâmica urbana e ambiental através do tempo, mostrando como os diferentes elementos se alteram ou persistem, analisamos através de um estudo de caso, as transformações que ocorreram no Rio Itajaí-Açu, na cidade de Blumenau/SC, desde a fundação até os dias atuais.
264

Aspectos qualitativos da água subterrânea no Campus da UFSM, Santa Maria - RS / Qualitative aspects of groundwater at UFSM Campus, Santa Maria RS

Moreira, Celina Maria Dutra 28 February 2005 (has links)
Nowadays there is an expressive increase of the use of groundwaters because of the lower cost for treatment, distribution and, mainly the scarcity of hydrous resources. Over the years 40 tubular wells were drilled to supply provide about 17.000 people, who circulate at UFSM Campus, according to data given from University Cityhall, only 20 wells are working, to provide average waste of 850m3/day of water taking for basis an average of 50 liters for person a day (NBR 7229/93). This supplying is all done for tubular wells and groundwaters are exploted by two kinds of rigs, through compressor or submerse pump. Like this, it was had the objective investigates the potability situation and readiness of the groundwaters in the Campus, through the collection and preparation of the database, analysis of the condition of operation of the wells, evaluation of the physiochemical and bacteriological quality of the waters of those wells, besides to investigate the available hydrodynamic parameters and to supply technical subsidize goes the granting of the resources groundwaters hydrous of the studied area. Identified that some wells present geological profiles of perforation and physiochemical and bacteriological analyses of the waters accomplished with some frequency. And the waters plows in agreement with the hidro-sanitary demands and with the established norms goes human consumption (OMS and it would Carry nº518/04). Later, with the software Surfer 8.0 the space distribution of the altitude was acted, depth, static level and flows of the wells, besides the net of flow of the groundwaters. Still the geological map, profiles lithological was elaborated and geological of the wells. It was simulated situations of word pumping in order to supply subsidize to the administration of the groundwaters in the Campus of UFSM. It was verified that there isn t a good control for piezometric levels, and according data of wells statics levels, according to its historic function, it was observed that they had lowered by the years and decrease of drainage. These results may be come from an increase of water consume or weather alterations, which change the capacity for reloading the aquifer, according to what was observed in the development of the weather hydric balance in the last five years. Aquifer System investigated is plain with wells depth oscillating between 51m and 128m and it belongs to Paraná s Basin, belonging to Guarani Aquifer System. / Atualmente há um aumento significativo do uso das águas subterrâneas, devido ao menor custo de tratamento, distribuição e, principalmente, escassez de recursos hídricos. Ao longo dos anos foram perfurados 40 poços tubulares para abastecer cerca de 17.000 pessoas, que circulam no Campus da UFSM, segundo a Prefeitura Universitária. Entretanto, apenas 20 poços estão ativos, para suprir um consumo médio de 850m³/dia de água tomando por base um consumo de 50 litros por pessoa dia (NBR 7229/93). Esse abastecimento é feito totalmente por poços tubulares e as águas subterrâneas são explotadas por meio de dois tipos de equipamentos, por compressor ou bomba submersa. Assim, teve-se como objetivo investigar a situação de potabilidade e disponibilidade das águas subterrâneas no Campus, através da coleta e preparação de um banco de dados, análise da condição de funcionamento dos poços, avaliação da qualidade físico-química e bacteriológica das águas desses poços, além de investigar os parâmetros hidrodinâmicos disponíveis e fornecer subsídios técnicos para a outorga dos recursos hídricos subterrâneos da área estudada. Identificou-se que alguns poços apresentam perfis geológicos de perfuração e análises físico-químicas e bacteriológicas das águas realizadas com certa periodicidade. Sendo que as águas estão de acordo com as exigências hidro-sanitárias e com as normas estabelecidas para consumo humano (OMS e Portaria nº518/04). Posteriormente, com o programa Surfer 8.0 representou-se a distribuição espacial da altitude, profundidade, nível estático e vazões dos poços, além da rede de fluxo das águas subterrâneas. Ainda elaborou-se o mapa geológico, perfis litológicos e geológicos dos poços. Simulou-se situações de bombeamento a fim de fornecer subsídios à gestão das águas subterrâneas no Campus da UFSM. Verificou-se também que não há um bom controle dos níveis piezométricos e conforme os dados de nível estático dos poços, notou-se que sofreram rebaixamento no decorrer dos anos e diminuição da vazão, fatores provavelmente oriundos do aumento do consumo de água ou das alterações climáticas que alteram a capacidade de recarga do aqüífero conforme observado no desenvolvimento do balanço hídrico climático dos últimos cinco anos. O sistema aqüífero explorado é raso com profundidades dos poços variando entre 51m a 128m e faz parte da Bacia do Paraná, pertencendo ao Sistema Aqüífero Guarani.
265

LEVANTAMENTO DA VULNERABILIDADE DOS RECURSOS HÍDRICOS SUBTERRÂNEOS NO MUNICÍPIO DE DONA FRANCISCA RS / RISING OF THE VULNERABILITY OF THE GROUNDWATER HYDRIC RESOURCES IN THE MUNICIPAL DISTRICT OF DONA FRANCIS C A - RS

Maziero, Leandro 28 February 2005 (has links)
The correct use and administration of the natural resources are of fundamental importance for the economical development and well to be social of a nation. The main objective of the work is the analysis of the natural vulnerability of the ground waters in the municipal district of Dona Francisca/RS. For this the model DRASTIC was used. This model is subdivided in seven factors, which are: D = depth of the static level; R = total recharge; A = half aquifer; S = soils; T = Topography; I = impact in the vadose zone; C = hydraulic conductivity. To this group of factors weights are attributed in agreement with the reduction capacity of pollutant that each it possesses. That is done in the intention of quantifying a called value of potential index of pollution. The vulnerability indexes suggested by the model extend of <35 (protected area) up to >120 (obligatory protection area). In the Municipal district of Dona Francisca, Rio Grande do Sul State southern of Brazil. Was arrived to indexes contained in the intervals of 65 - 95 (vulnerable area 38% of the total), high vulnerability in the interval 95 120 (38% of the total area) by last bigger than > 120 (obligatory protection area 10%). They were simulated 21 wells, being 12 of the type manual drilled and 9 of the tubular type. They were spaced in GIS (Geographical Information System) with the use of the software Surfer 8 the following parameters: electric conductivity, total dissolved solids (TDS), potentiometric surface and the vulnerability index. Through the software Spring 4.1 were mapped the use of the earth, the geology and the steepness of the land. Starting from the mapping of the potentiometric surface was verified a tendency of ground water flow of northwest to southeast. Through the rising of the natural vulnerability of the mapped area can be defined the use and occupation of the soils location and potentiality contaminant activities dispose in this area of 104 Km2. / O correto uso e gerenciamento dos recursos naturais são de fundamental importância para o desenvolvimento econômico e bem estar social de uma nação. Assim, o objetivo deste trabalho é a análise da vulnerabilidade natural das águas subterrâneas no município de Dona Francisca/RS. Para tal análise, lançou-se mão do modelo DRASTIC. O referido modelo é subdividido em em sete fatores, quais sejam: D= profundidade do nível estático; R= recarga total; A= meio aqüífero; S= solos; T= topografia; I= impacto na zona vadosa; C= condutividade hidráulica. A este conjunto de fatores são atribuídos pesos de acordo com a capacidade de atenuação de poluentes que cada um possui. Isto é feito no intuito de quantificar um valor chamado de índice de vulnerabilidade. Os índices sugeridos pelo modelo se estendem de <35 (área protegida) até >120 (área de proteção obrigatória). No Município de Dona Francisca/RS, extremo sul do Brasil, foram simulados 21 poços. Destes, chegou-se às classes Área Vulnerável (38% da área) com índices contidos entre de 65 95; Muito Vulnerável (52% da área) no intervalo de 95 a 120 e por fim, na classe de Proteção Obrigatória (10% da área) na classe > 120, numa área total de 104 Km2. Dos 21 poços, 12 são do tipo cacimba e 9 do tipo tubular. Foram espacializados em SIG (Sistema de Informações Geográficas) com o uso do Aplicativo Surfer 8 os seguintes parâmetros: condutividade elétrica, sólidos totais dissolvidos (STD), superfície potenciométrica e vulnerabilidade. Por meio do Aplicativo Spring 4.1 foram espacializados a declividade do terreno, a geologia e o uso da terra. A partir da espacialização da superfície potenciométrica constatou-se uma tendência de fluxo subterrâneo de noroeste para sudeste/sul. Por meio do levantamento da vulnerabilidade natural da área pode-se definir espacialmente o uso e ocupação dos solos. Assim, torna-se possível avaliar a melhor localização para dispor atividades potencialmente contaminantes no Município de Dona Francisca/RS, em relação a vulnerabilidade natural dos aqüíferos.
266

ESTUDO DA DINÂMICA HÍDRICA DE UM RESERVATÓRIO AFETADO PELA CONSTRUÇÃO DE UM SEGUNDO RESERVATÓRIO A MONTANTE / STUDY OF THE WATER BALANCE OF A RESERVOIR AFFECTED BY THE CONSTRUCTION OF A SECOND RESERVOIR TO THE UPSTREAM

Andreis, Caren 23 July 2004 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The construction of reservoirs in sequence in the same basin has produced great problems in rural environment. It is supposed that reservoirs constructed in downstream of a second reservoir have their discharge affluent altered, or reduced, what generates conflict among proprietaries, since the proprietary of a reservoir in a downstream, will always be supposedly the harm one. The present paper has as objective to determine if, in fact, there are reductions and what the intensity of this reduction in the discharge affluent of a reservoir is (denominate here R1), that suffers influence of a second reservoir (R3), constructed in upstream. To come up to the methodology simulations were done through the use of the methodology of the water balance in reservoirs. The results show that, when the water is not taken off from R3 to irrigation, this do not influence practically anything in the water balance and the storage of R1. When the water is taken off from R3 to irrigation, this influences the storage volume in R1, but not up to the point of lacking water to irrigation of the proposed areas to the two reservoirs. When considered the dynamic capacity to determine the irrigation areas of R1 and R3, the greater total irrigation area was obtained in the simulation that considered the existence of two reservoirs, being the irrigation areas of these, determined from our dynamic capacities. In this case, the result of irrigation areas was 290 ha, more 90 ha than when only considered the static capacities in the estimation of the irrigation areas. / A construção de reservatórios em seqüência em uma mesma bacia hidrográfica tem gerado grandes problemas no meio rural. Supõe-se que reservatórios construídos à jusante de outro reservatório têm sua vazão afluente alterada, ou melhor, reduzida, o que gera conflitos entre os proprietários destes, uma vez que o proprietário do reservatório a jusante, supostamente, sempre será o prejudicado. O presente trabalho tem como objetivo determinar se realmente há reduções e qual a intensidade desta redução na vazão afluente de um reservatório (aqui denominado R1), que sofre influência de outro reservatório (R3), construído à montante. Para tal, foram feitas simulações a partir da metodologia do balanço hídrico de reservatórios. Os resultados demonstram que, quando não há a retirada de água do R3 para irrigação, este não influencia praticamente nada o balanço hídrico e o armazenamento do R1. Quando há a retirada de água do R3 para irrigação este influencia os volumes armazenados no R1, porém não a ponto de faltar água para irrigação das áreas propostas para os dois reservatórios. Quando considerada a capacidade dinâmica na determinação das áreas de irrigação de R1 e R3, a maior área total de irrigação foi obtida na simulação que considerou a existência dos dois reservatórios, sendo as áreas de irrigação destes, determinadas a partir de suas capacidades dinâmicas. Neste caso, a área total de irrigação resultante foi de 290 ha, 90 ha a mais do que quando consideradas as capacidades estáticas no cálculo das áreas de irrigação.
267

PLANO DE PROTEÇÃO DE AQÜÍFEROS A PARTIR DE VARIÁVEIS AMBIENTAIS / AQUIFERS PROTECTION PLAN THE FROM AMBIENT VARIABLES

Dutra, Denecir de Almeida 10 May 2005 (has links)
The available water reserve, economically viable for the human consumption, only restricts that parcel that if finds in the superficial and groundwater form, that represents only 0.7% of the water fresh existing in the surface of the Land. Like this, the present study it had as objective generality to propose a plan of protection of aquifers for the watershed of the Arroio Ferreira, located in the city of Santa Maria/RS. The specific objectives were to identify the from partner-ambient variables of the watershed, to elaborate plain of information with the use of the technology GIS and to establish the crossing of the information plans, being gotten itself thus zones of aquifers protection. In this way, defined five zones of protection of the aquifers: Zone I - Immediate protection, Zone II - Restriction and control, Zone III - Without restriction, Zone IV - Prevention and Zone V - Direct influence of watercourse, adapted of the norms established for the protection of the wells and areas of aquifers recharge, as well as of previous works. As we could observe the watershed of the Arroio Ferreira presents propitious natural conditions to the contamination of groundwaters, beyond to belong hydrogeology of the Aquifer System Guarani. The generated plans of information with the use of the technology GIS, had assisted for the definitions of the zones of protection of the aquifers. Conclude, therefore that, the preservation of the amount and the quality of the groundwater, as much for this as for the future generations, not only depends on the actions of the professionals of the area, but also of each individual of the society, respecting the restrictions and conditions proposals to the implantation or development of socioeconomic as activities, as well as of the measures of control of the sources of pollution in each zone of protection. / A reserva de água disponível, economicamente viável para o consumo humano, restringe-se somente aquela parcela que se encontra na forma de água superficial e subterrânea, que representa apenas 0,7% da água doce existente na superfície da Terra. Deste modo, o presente estudo teve como objetivo geral propor um plano de proteção dos aqüíferos para a microbacia hidrográfica do Arroio Ferreira, localizado no município de Santa Maria/RS. Sendo os objetivos específicos identificar as variáveis sócio-ambientais da microbacia, elaborar planos de informação com o uso das técnicas de SIG e estabelecer o cruzamento dos planos de informação, obtendo-se assim zonas de proteção dos aqüíferos. Desta forma, definiu-se cinco zonas de proteção dos aqüíferos: Zona I - Proteção imediata, Zona II - Restrição e controle, Zona III - Sem restrição, Zona IV Prevenção e Zona V Influência direta de cursos d água, adaptadas das normas estabelecidas para a proteção dos poços e áreas de recarga aqüífera, bem como de trabalhos anteriores. Como pudemos observar a microbacia do Arroio Ferreira apresenta condições naturais propícias à contaminação das águas subterrâneas, além de fazer parte hidrogeológicamente do Sistema Aqüífero Guarani. Os planos de informação gerados com o uso das técnicas de geoprocessamento, auxiliaram para as definições das zonas de proteção dos aqüíferos. Conclui-se, portanto que, a preservação da quantidade e da qualidade da água subterrânea, tanto para esta como para as futuras gerações, depende não somente das ações dos profissionais da área, mas também de cada indivíduo da sociedade, respeitando as restrições e condições propostas à implantação ou desenvolvimento de atividades socioeconômicas, bem como das medidas de controle das fontes de poluição em cada zona de proteção.
268

AVALIAÇÃO DA QUALIDADE DA ÁGUA E DOS RESÍDUOS SÓLIDOS NO SISTEMA DE DRENAGEM URBANA / EVALUATION OF WATER QUALITY AND LITTER IN THE URBAN DRAINAGE SYSTEM

Brites, Ana Paula Zubiaurre 25 February 2005 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work was developed to evaluate the pollutant load of water and litter, transmitted by the net of urban drainage, in two catchments, located at Santa Maria RS. Water quality and litter data were collected and compared between catchments and used to determine how they are affected by variables such as precipitation, land use, physical characteristic of the area and antecedent dry weather period. The cachtment Cancela area is 4,95km², with 56% of urban area; the size of cachtment Alto da Colina is 3,34 km², with 22,3% of urban area. Water quality characteristics were evaluated through the parameters: BOD, total and faecal coliforms, electric conductivity, turbidity, pH, solid suspended and temperature. The litter were appraise through the quantification in weight and volume. The results indicate that the catchment Cancela presented larger diffuse and litter load than the catchment Alto da Colina, showing the degradation process, associate to the characteristics of each studied area, as size and, mainly, to use and occupation of the soil. The two areas present high degradation process due to human activities such as the growth of urbanization, the sewer spilling and release of litter in the receiving bodies. / O desenvolvimento deste trabalho teve como objetivo avaliar a carga poluente da água e de resíduos sólidos, veiculados pela rede de drenagem urbana, em duas bacias hidrográficas, localizadas na cidade de Santa Maria - RS, onde os resultados encontrados foram comparados entre si, obtendo-se um prognóstico quanto aos fatores intervenientes, alterando variáveis como: precipitação, uso e ocupação do solo, características físicas da área e período de tempo seco antecedente ao evento. A bacia hidrográfica Cancela possui área de 4,95km², com 56% da área urbana; a bacia Alto da Colina possui área de 3,34 km², com 22,3% da área urbana. As características de qualidade da água foram avaliadas através dos parâmetros: DBO5, coliformes totais e fecais, condutividade elétrica, turbidez, pH, sólidos suspensos e temperatura. Os resíduos sólidos foram avaliados através da quantificação em peso e volume. Os resultados indicam que a bacia hidrográfica Cancela apresentou carga difusa e de resíduos maior que a bacia hidrográfica Alto da Colina, mostrando o processo de degradação, associado às características de cada área estudada, como tamanho e, principalmente, uso e ocupação do solo. As duas áreas apresentam processo de degradação elevado devido às atividades antrópicas, como o crescimento da urbanização, o despejo de esgoto e lançamento de resíduos sólidos nos corpos receptores.
269

Desenvolvimento de uma ferramenta personalizada em sistema de informações geográficas, para identificar áreas de risco a inundação em obras lineares: uma aplicação prática em dutovias

Cucolo, Fabiano Felipe [UNESP] 10 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-10Bitstream added on 2014-06-13T20:54:19Z : No. of bitstreams: 1 cucolo_ff_me_rcla.pdf: 421868 bytes, checksum: 77b170aee7a37f3fcdaa490d2c6cf75a (MD5) / Este trabalho atende projetos que pretendem utilizar análises hidrológicas em sistemas de informação geográfica até então pouco exploradas. Analises hidrológicas para inundação são realizadas a anos, porem ainda pouco exploradas quando o assunto é voltado ao mapeamento. Este projeto tem como objetivo determinar uma análise geográfica sobre inundação, explorando os métodos disponíveis para sistema de informações geográficas, assim como explorá-los detalhadamente. Neste estudo a aplicação se deu em uma obra linear – dutovia. / This work meets projects that intend to use hydrological analysis in geographic information systems, today few explored. Hydrologic analysis for flooding are carried out to years, but still poorly exploited when it is back to mapping. This project to determine a geographical analysis of flood, exploring the methods available for geographic information systems, and exploit them further. In this study the application was in a pipeline.
270

Estudo do assoreamento e sua relação com a vida útil do reservatório Represa Velha, CEPTA/IBAMA, Pirassununga/SP

Bufon, André Gustavo Mazzini [UNESP] 03 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-03Bitstream added on 2014-06-13T20:23:25Z : No. of bitstreams: 1 bufon_agm_dr_rcla.pdf: 6403012 bytes, checksum: c784c56fb01a8bcc3cc685a03f66bd99 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho teve como finalidade aplicar análise espacial, visando elaborar um modelo estocástico para determinação do tempo de vida útil de um reservatório de pequeno porte localizado no Centro de Pesquisa e Gestão de Recursos Pesqueiros Continentais (CEPTA/IBAMA)/Pirassununga (SP). Para elaboração do modelo foram utilizados dois métodos: densidade aparente do sedimento utilizando câmaras de sedimentação e batimetria do reservatório. As variáveis estudadas revelaram para o potencial hidrogeniônico (pH) concentrações entre 8,71 e 2,15; oxigênio dissolvido no fundo entre 12,48 e 0,20 mg.L-1; temperatura da água no fundo entre 28,85 e 16,00ºC; transparência da água entre 1,30 e 0,25 m; material em suspensão total entre 618,30 e 2,45 mg.L-1; material em suspensão inorgânico entre 425,80 e 0,20 mg.L-1; material em suspensão orgânico entre 192,60 e 2,15 mg.L-1 e condutividade elétrica da água no fundo entre 40,00 e 5,00 æS.cm-1. Quanto aos resultados da batimetria, verificou-se que houve perda significativa de profundidade durante o ano de 1998. Ao comparar as análises de batimetria e material em suspensão total (MST) verificou-se a perda da profundidade durante os 4 anos estudados de -1,32 m e pela câmara de sedimentação observou-se um ganho de sedimento de 584,05 mg.L-1. Como conclusão obteve-se o valor de 50 anos como o tempo de vida útil da represa. / The purpose of this work is to apply space analysis aiming elaborate a stochastic model for time determination of useful life of a small size reservoir at the Centre of Research and Administration of Continental Fishing Resources (CEPTA/IBAMA)/Pirassununga (SP). For model elaboration were used two methods: apparent density of the sediment using reservoir sedimentation and bathymetry cameras. The studied variables revealed for the pH concentrations between 8,71 and 2,15; oxygen dissolved in the bottom between 12,48 and 0,20 mg.L -1; water temperature in the bottom between 28,85 and 16,00ºC; water transparency between 1,30 and 0,25 m; material in total suspension between 618,30 and 2,45 mg.L-1; material in inorganic suspension between 425,80 and 0,20 mg.L-1; material in organic suspension between 192,60 and 2,15 mg.L-1 and electric conductivity of water in the bottom between 40,00 and 5,00 æS.cm-1. Regarding bathymetry results, it verified that there was significant loss of depth during the year of 1998. When comparing bathymetry and material analyses in total suspension it was verified depth loss during the 4 years studied of -1,32 m and by the sedimentation camera a sediment gain of 584,05 mg.L-1 was observed. As conclusion it obtained the value 50 year as time of useful life for dam.

Page generated in 0.0489 seconds