• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 120
  • 70
  • 23
  • 18
  • 17
  • 17
  • 16
  • 14
  • 14
  • 14
  • 14
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Investigação do processo de foto-ionização associativa em situações com baixa dimensão / Photoassociative ionization in situations with low dimensions

Paiva, Rafael Rothganger de 17 February 2009 (has links)
Neste trabalho estudamos o processo de foto-ionização associativa(PAI) em uma amostra fria de átomos de sódio com o objetivo entender os efeitos dos estados repulsivos e dimensão da colisão. Realizamos experimentos de PAI com duas cores em uma armadilha magneto-óptica adicionando um feixe de prova com intensidade, frequências e polarização ajustáveis. O formato dos átomos aprisionados também foi uma das variáveis no estudo da PAI. Para os átomos em formação esférica, observamos uma mudança marcante no comportamento da constante de taxa de formação da foto-ionização associativa(K) para um determinado domínio de frequências, e essa mudança no comportamento pode ser atribuída a participação de estados moleculares repulsivos na PAI e a formação de um possível cruzamento evitado entre os níveis moleculares. No atomotron ,armadilha atômica em forma de anel, variamos a polarização do laser de prova e constatamos que a razão entre K das polarizações paralela e perpendicular ao movimento dos átomos é igual a 4. Uma comparação entre K do atomotron e o da armadilha esférica em função da intensidade do feixe de prova, nos mostrou uma diferença no comportamento e no valor da constante de taxa. / Photoassociative ionization (PAI) in a cold sample of sodium atoms was the main subject of our studies as a way to understand the effects of repulsive states and collision dimensions. Two-color PAI experiment were preformed in a magneto-optical trap (MOT) trough the addition of a probe laser beam, the intensity, polarization and frequency of that probe laser were tunable. The shape of the trapped atoms also could be changed. In a spherical shape MOT, we observed a marked change in the PAI rate constant (K) for a definite frequency range, and that change can be attributed to the influence of repulsive molecular states and the a possible formation of an avoided crossing between molecular levels. In atomotron, ring shaped mot, we changed the polarization of the probe beam, and saw that the ratio between K for a polarization parallel to the atoms motion and a perpendicular one is 4. Comparing the K as a function of the intensity between a spherical shaped mot and atomotron showed us a difference in the behavior and the value of the rate constant.
92

Avaliação da metodologia de espectrometria de massas MALDI-TOF (VITEK MS®) para identificação de espécies de Aspergillus de importância médica / Evaluation of the MALDI-TOF mass spectrometry (VITEK MS®) methodology for the identification of clinically relevant Aspergillus

Antunes, Fernanda Marques Americo 29 March 2019 (has links)
A especiação de isolados clínicos de Aspergillus ganhou relevância nos últimos anos devido à descrição de espécies crípticas resistentes aos derivados azólicos. A identificação morfológica convencional não é capaz de discriminar as espécies de Aspergillus e o sequenciamento de DNA é uma técnica pouco adaptada a laboratórios clínicos. A espectrometria de massas por ionização/dessorção a laser auxiliada por matriz tempo-devoo (EM MALDI-TOF) é uma metodologia emergente que vem sendo explorada com intuito de fornecer identificação rápida e acurada de microrganismos, incluindo os fungos filamentosos de importância clínica. Entretanto, há poucos estudos avaliando a plataforma VITEK MS® para a identificação de espécies de Aspergillus. O presente estudo teve como objetivo fornecer dados adicionais sobre a performance dos sistemas do VITEK MS® e suas bibliotecas de espectros de referências (ER) In Vitro Diagnostics (IVD) e Research Use Only (RUO) para identificar as espécies de Aspergillus de relevância clínica. Uma biblioteca de ER in-house também foi construída e avaliada. Um total de 106 organismos foram avaliados por EM, incluindo 47 cepas provenientes das coleções de fungos do Westerdijk Fungal Biodiversity Institute (Holanda) e do LEMIUNIFESP, seis isolados ambientais (IMT-USP) e 53 isolados cínicos do HC-FMUSP. Foram utilizados dois protocolos de extração proteica, um recomendado pelo fabricante e outro empregando meio de cultura líquido para os isolados/cepas com baixa esporulação. Trinta e cinco organismos foram selecionadas para construir os ERs, e os 71 restantes foram usados para avaliação de desempenho das bibliotecas IVD, RUO e RUO+in-house. Entre os 71 organismos analisados, 91,5%, 84,5% e 100% tiveram identificação correta de gênero pelos bibliotecas IVD, RUO e RUO+in-house, respectivamente. Enquanto para identificação de espécie, as bibliotecas IVD, RUO e RUO+in-house mostraram 83,1%, 77,4% e 90,1% de identificações de espécie, respectivamente. Para as 16 espécies crípticas de Aspergillus analisadas, a identificação foi correta em 31,2%, 18,7% e 62,5%, pelos sistemas IVD, RUO e RUO+in-house, respectivamente. Entre as espécies crípticas resistentes aos derivados azólicos, o sistema IVD forneceu identificação correta para as espécies Aspergillus lentulus, Aspergillus calidoustus e Aspergillus sydowii. Entretanto, Aspergillus fumigatiaffinis e Neosartorya pseudofischeri foram erroneamente identificadas como Aspergillus fumigatus pelo sistema IVD. A biblioteca in-house demonstrou melhor performance, mas espécies filogeneticamente próximas como A. fumigatiaffinis e A. lentulus tiveram identificações cruzadas. Concluímos que o VITEK® MS demonstrou boa performance para a identificação das espécies de Aspergillus, porém para algumas espécies crípticas, há necessidade de melhoria das bibliotecas de espectro de referência comercializadas. Algumas espécies crípticas filogeneticamente relacionadas apresentaram espectros similares e são de difícil diferenciação por EM MALDI, mesmo com a construção de uma biblioteca de ER in-house com vários representantes de cada espécie / Aspergillus spp. identification has become more relevant in clinical practice since azoleresistant cryptic species have emerged in the last years. Conventional morphologic identification is not able to discriminate Aspergillus species and DNA sequencing is not feasible for clinical laboratories. Matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) is an emergent technology that has been explored to provide fast and accurate identification of microorganisms, including clinically relevant molds. However, only a few studies have explored the platform VITEK MS® for the identification of Aspergillus species. The present study aimed to provide additional data regarding the performance of the In Vitro Diagnostics (IVD) and Research Use Only (RUO) systems for the identification of Aspergillus species, including azoleresistant ones, and also to construct and to evaluate an in-house reference spectrum library. A total of 106 organisms were evaluated by MS, including 47 Aspergillus strains (Westerdijk Fungal Biodiversity Institute and LEMI-UNIFESP collections), six environmental (IMT-USP) and 53 clinical isolates (HC-FMUSP). Two protein extraction protocols were used, one recommended by the manufacturer and another with liquid broth for the organisms with poor sporulation. Thirty-five organisms were selected to construct the in-house reference spectrum library and the remaining 71 were used for the performance evaluation. Correct genus identification was provided in 91.5%, 84.5% and 100% by the IVD, RUO, and RUO+in-house reference spectrum libraries, respectively. Correct species identification was provided in 83.1%, 77.4% and 90.1% by the IVD, RUO, and RUO+in-house reference spectrum libraries, respectively. Among the 16 Aspergillus cryptic species, correct identification was provided in 31.5%, 18.7% and 62.5% by the IVD, RUO, and RUO+in-house reference spectrum libraries, respectively. Among the azole-resistant cryptic species, the IVD system provided correct identification for Aspergillus lentulus, Aspergillus calidoustus and Aspergillus sydowii. However, Aspergillus fumigatiaffinis and Neosartorya pseudofischeri were misidentified as Aspergillus fumigatus by the IVD system. The in-house library had better performance for the identification of Aspergillus cryptic species, but closely related taxa may be difficult to have correct differentiation by MALDI-TOF MS. In conclusion, VITEK® MS showed good performance for the identification of Aspergillus species and some azoleresistant species. However, a more robust reference spectrum library including more representatives of azole-resistant cryptic species may be necessary to achieve better identification performance of closely related taxa
93

Desenvolvimento de fontes radioativas seladas imobilizadas em resina epóxi para verificação de detectores utilizados em Medicina Nuclear / Development of sealed radioactive sources immobilized in Epoxy resin for verification of detectors used in nuclear medicine

Tiezzi, Rodrigo 04 February 2016 (has links)
As fontes radioativas seladas são usadas na verificação de detectores de câmara de ionização, os quais medem a atividade dos radioisótopos usados nas mais diversas áreas, como na Medicina Nuclear. A medida da atividade dos radioisótopos deve ser feita com exatidão, pois será administrada em um paciente. Para garantir o adequado funcionamento dos detectores de câmara de ionização, são estipulados ensaios normatizados pela Agência Internacional de Energia Atômica (IAEA) e a Comissão Nacional de Energia Nuclear (CNEN) utilizando-se fontes radioativas seladas de Bário-133, Césio-137 e Cobalto-57. Os testes avaliam a exatidão, precisão, reprodutibilidade e linearidade da resposta do equipamento. O foco deste trabalho foi o estudo e o desenvolvimento dessas fontes radioativas padrão de Bário-133, Césio-137 e Cobalto-57, utilizando um polímero, no caso resina epóxi comerciais do tipo éter diglicidílico do bisfenol A e um agente de cura a base de poliamina modificada da dietilenotriamina ,para imobilizar o material radioativo. A matriz polimérica apresenta a função primordial de fixar e imobilizar o conteúdo radioativo não permitindo seu vazamento dentro dos limites técnicos exigidos pelas normas de proteção radiológica no quesito de características de uma fonte selada e, adicionalmente, ter a capacidade de reter a emanação de quaisquer gases que venham a se formar durante o processo de fabricação e do período de vida útil deste artefato. O processo de manufatura de uma fonte selada padrão consiste no envasamento, em um frasco de geometria padronizada, de uma quantidade, em volume fixo, de uma matriz polimérica no interior da qual é adicionada e dispersada homogeneamente uma quantidade precisa e exata em atividade de um material radioativo padrão. Nesse sentido, realizou-se um estudo para a escolha da resina epóxi, analisando suas características e propriedades. Foram realizados estudos e testes, verificando a máxima miscibilidade da resina com a água (solução ácida, simulando as condições da solução radiativa), perdas de propriedades mecânicas e térmicas, bem como o controle de dose radioativa para a completa cura (irradiadores de cobalto).Foram produzidas fontes de césio-137 e bário-133, realizou-se testes para determinação do grau de homogeneidade na dispersão do material radioativo na matriz e testes de imersão das fontes seladas produzidas para verificar a estanqueidade do sistema desenvolvido, obtendo um resultado satisfatório de acordo com as normas. Analisando todos os resultados obtidos, as fontes seladas podem ser confeccionadas em matriz epóxi DGEBA e endurecedor poliamínico DETA modificado, desde que a quantidade de material radioativo, na forma de solução ácida, adicionado à composição não ultrapasse um teor de 20%. A cura da resina epóxi pode ser melhorada em relação a ambiente, com uso da irradiação desde que seja exposta a uma dose ao redor de 33 kGy durante a cura. Nos testes de estanqueidade, verificou-se que as fontes são estanques, as medições da atividade da água utilizada nos testes mostraram um valor inferior a 185 Bq (de acordo com a International Standard Organization- Radiation protection sealed radioactive sources - ISO 9978), comprovando a eficiência da resina epóxi como material para selar o material radioativo. Tendo a finalidade de criar uma tecnologia nacional capaz de suprir a demanda deste produto no mercado interno e atingir excelência em qualidade através da acreditação e certificação do produto junto aos órgãos competentes. / The radioactive sealed sources are used in verification ionization chamber detectors, which measure the activity of radioisotopes used in several areas, such as in nuclear medicine. The measurement of the activity of radioisotopes must be made with accuracy, because it is administered to a patient. To ensure the proper functioning of the ionization chamber detectors, standardized tests are set by the International Atomic Energy Agency (IAEA) and the National Nuclear Energy Commission using sealed radioactive sources of Barium-133, Cesium-137 and Cobalt-57. The tests assess the accuracy, precision, reproducibility and linearity of response of the equipment. The focus of this work was the study and the development of these radioactive sources with standard Barium-133 and Cesium-137, using a polymer, in case commercial epoxy resin of diglycidyl ether of bisphenol A (DGEBA) and a curing agent based on modified polyamine diethylenetriamine (DETA), to immobilize the radioactive material. The polymeric matrix has the main function of fix and immobilize the radioactive contents not allowing them to leak within the technical limits required by the standards of radiological protection in the category of characteristics of a sealed source and additionally have the ability to retain the emanation of any gases that may be formed during the manufacture process and the useful life of this artifact. The manufacturing process of a sealed source standard consists of the potting ,into bottle standardized geometry, in fixed volume of a quantity of a polymeric matrix within which is added and dispersed homogeneously to need and exact amount in activity of the radioactive materials standards. Accordingly, a study was conducted for the choice of epoxy resin, analyzing its characteristics and properties. Studies and tests were performed, examining the maximum miscibility of the resin with the water (acidic solution, simulating the conditions of radioactive solution), loss of mechanical and thermal properties, as well as the radioactive dose control for complete curing (cobalt irradiators). For this work was produced a sources of barium-133 and cesium -137,tests were conducted to determination the degree of homogeneity in the dispersion of the radioactive material in the matrix and immersion tests of sealed sources produced to verify the leakage (ISO 9978) of the developed system, occurring obtaining a satisfactory result. With the purpose of creating a national technology able to meet the demand of this product in the domestic market and achieve excellence in quality through accreditation and certification of the product by the appropriate bodies.
94

Padronização da espectrometria de massa MALDI-TOF para identificação de cepas de Trichosporon spp. de importância médica / Standardization of MALDI-TOF mass spectrometry for identification of Trichosporon spp of medical relevance

Almeida Júnior, João Nobrega de 01 April 2014 (has links)
O gênero Trichosporon é composto por leveduras artrosporadas do Filo Basidiomycota e é conhecido agente de infecção fúngica invasiva (IFI) em pacientes imunodeprimidos ou com outros fatores de risco. Em pacientes onco-hematológicos é a principal levedura responsável por IFI depois do gênero Candida. Entre as espécies responsáveis por infecções no homem encontram-se: T. asahii, T. inkin, T. mucoides, T. dermatis, T. jirovecii, T. ovoides, T. cutaneum, T. montevideense, T. domesticum, T. asteroides, T. coremiiforme, T. faecale, T. dohaense, T. lactis, T. japonicum. A tecnologia de identificação de fungos por espectrometria de massa (SM) MALDI-TOF ainda carece de padronização para identificação de fungos do gênero Trichosporon, mas a literatura mostra resultados encorajadores. O objetivo deste estudo é padronizar a técnica de espectrometria de massa MALDI-TOF para a identificação das espécies do gênero Trichosporon de importância médica. O estudo foi realizado em cooperação entre a Divisão de Laboratório Central do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (DLC, HC-FMUSP), Instituto de Medicina Tropical da USP (IMT-USP), Instituto Adolfo Lutz (IAL) e Laboratoire de Parasitologie-Mycologie do Hospital Saint Antoine de Paris, vinculado ao grupo de pesquisa INSERM/UPMC UMR S945 \"Immunité et Infection\" Faculté de Medecine et Université Pierre et Marie Curie de Paris. Noventa e três cepas/isolados foram analisado(a)s, sendo dezenove cepas de referência adquiridas junto à coleção holandesa Centraalbureau Schimmelcultures (CBS), 19 isolados do HC-FMUSP e IAL, e 55 isolados de diferentes hospitais franceses. A identificação molecular foi realizada através do sequenciamento da região IGS1 do rDNA e foi considerada como método de referência. O protocolo de extração de proteínas foi estabelecido através da comparação do desempenho de três metodologias (Bruker®, Cassagne et al., Sendid et al.). Os espectros de massa foram obtidos no laboratório de bacteriologia do Hospital Saint Antoine de Paris através do aparelho Microflex LT®. A interpretação dos resultados qualitativos e quantitativos (logscore) foi realizada através do Software Biotyper 3.0®. O desempenho de identificação do banco de espectros de referência Biotyper 3.0® foi comparado a outros cinco bancos criados a partir de espectros de referência (ERs) derivados de 18 cepas de referência CBS, sete isolados clínicos e 11 ERs do banco Biotyper 3.0. O protocolo de extração de proteínas descrito por Sendid et al. foi escolhido como protocolo de referência pois os espectros produzidos tiveram logscore superiores àqueles obtidos através do método do fabricante. O banco de ERs Biotyper 3.0® apresentou 32,3% de identificações corretas das espécies, sendo que o banco de ERs in house (número 5, constituído cepas CBS e isolados clínicos) apresentou 98,5% de identificações de espécies. Espectros de referência do banco de dados Biotyper 3.0® foram submetidos à identificação com a utilização dos ERs criados a partir de cepas CBS e isolados clínicos e foram evidenciados com erros de identificação: T. mucoides (2), T. ovoides (1) e T. cutaneum (2). Após padronização do protocolo de extração e criação de banco de ERs com cepas CBS e isolados clínicos caracterizados pelo sequenciamento da região IGS, a SM por MALDI-TOF apresentou-se como potente uma ferramenta para a identificação de fungos do gênero Trichosporon. O banco de ERs Biotyper 3.0® apresentou um fraco desempenho, relacionado a ERs que foram criados a partir de cepas mal identificadas / Trichosporon spp. are arthrospored yeasts from the Filum Basidiomycota that are known to produce invasive fungal infection (IFI) in patients with immunosupression or other risk factors. After Candida, Trichosporon is the second genus of yeasts responsible for IFI in patients with onco-hematological diseases. The most important species related to human infection are: T. asahii, T. inkin, T. mucoides, T. dermatis, T. jirovecii, T. ovoides, T. cutaneum, T. montevideense, T. domesticum, T. asteroides, T. coremiiforme, T. faecale, T. dohaense, T. lactis, T. japonicum. The technology of mass spectrometry (MS) for identification of Trichosporon species has not yet been standardized. However, preliminary promising results can be found in the literature. The objective of this study is to analyse and validate MS MALDI-TOF for the identification of Trichosporon species of medical relevance. This was a multicentric study with collaboration from the Central Laboratory Section from Clinics Hospital of the Medical School from the University of São Paulo (DLC-HCFMUSP), Tropical Medicine Institute from the University of São Paulo (IMT-USP), Instituto Adolfo Lutz (IAL) and Laboratoire de Parasitologie-Mycologie from the Hospital Saint Antoine of Paris and INSERM/UPMC UMR S945 \"Immunité et Infection\", Faculté de Medecine et Université Pierre et Marie Curie of Paris. Ninety three strains/isolates belonging to sixteen Trichosporon species were analysed. Nineteen were purchased from Centraalbureau Schimmelcultures (CBS) yeast collection, 19 belonged to HC-FMUSP and IAL collections, 55 belonged to different French collections. The reference identification method was the IGS1 rDNA sequencing. A protein extraction protocol was first established after comparing the performance of three different methodologies (Bruker(TM), Cassagne et al., Sendid et al.). The mass spectra were obtained through a Microflex LT(TM) mass spectrometer located at the bacteriology laboratory from Saint Antoine Hospital, Paris. Mass spectra, qualitative and quantitative results were produced through the software Biotyper 3.0(TM). The performance of the original main spectrum (MSP) library was compared to other 5 in house libraries built with the combination of MSPs derived from CBS strains (18), clinical strains (7) or (Bruker Daltonics/BD, Germany/USA) (11). The extraction protocol described by Sendid et al. showed better performance when compared to the manufacturer\'s one and was chosen for the subsequent extractions. Among the 6 different reference spectra databases tested, a specific one composed of 18 reference strains plus 7 clinical isolates (database 5) allowed the correct identification of 66 amongst 67 clinical isolates (98,5%). Biotyper 3.0 library produced only 32,3% of correct identifications. Biotyper\'s MSPs were submitted to cross-identification with MSPs derived from CBS strains and clinical isolates and misidentified original MSPs were identified: T. mucoides (2), T. ovoides (1) e T. cutaneum (2). While until now less widely applied to basidiomycetous fungi, MALDI-TOF appears to be a valuable tool for identifying clinical Trichosporon isolates at the species level. The MSP library Biotyper 3.0 showed a poorer performance which was due to misidentified strains utilized as reference for the MSPs
95

Medidas do primeiro coeficiente de Townsend de ionização em misturas gasosas utilizadas em microdosimetria / Measurements of the first Townsend ionization coefficient in gaseous mixtures employed in microdosimetry

Petri, Anna Raquel 17 April 2017 (has links)
Microdosímetros gasosos geralmente empregam uma mistura gasosa equivalente ao tecido humano mole (Tissue-equivalent Gas TEG), composta de um hidrocarboneto, dióxido de carbono e nitrogênio, de forma que o poder de freamento na mistura e no tecido sejam semelhantes. Entretanto, independentemente do hidrocarboneto adotado, dados tanto teóricos como experimentais do primeiro coeficiente de Townsend de ionização (α) nestas misturas são raros, ainda que a primeira TEG, cujo metano é o gás majoritário, tenha sido proposta em 1956 por Rossi e Failla e continue sendo amplamente utilizada. Neste trabalho, dados do parâmetro α em TEGs baseadas no metano (CH4 64,4%, CO2 32,4% e N2 3,2%) e nos isômeros do butano (C4H10 51,4%, CO2 42,3% e N2 6,3%) são apresentados pela primeira vez em geometria planar para a faixa de campo elétrico normalizado pela densidade do gás (E/N) entre 100 290 Td (1 Td = 10-21 V.m2). O método de medidas adotado baseia-se na técnica de Townsend pulsada, onde o primeiro coeficiente de Townsend pode ser determinando comparando a corrente elétrica no regime de avalanche e a corrente de ionização primária gerada pela incidência de um feixe de laser de nitrogênio em um eletrodo metálico (catodo) de uma câmara de geometria planar, sendo o anodo um eletrodo de alta resistividade (ρ=2×1010Ω.m). O aparato experimental, até então operado apenas em pressão atmosférica, foi modificado para também trabalhar em baixa pressão (120 hPa), de modo a aumentar a faixa de E/N investigada. A validação do método e das alterações do sistema de detecção foi realizada utilizando os três gases componentes das TEGs cujos parâmetros de transporte são amplamente estudados: o nitrogênio, o dióxido de carbono e o metano. Observou-se que o parâmetro na TEG com metano assemelha-se com os valores determinados para o metano puro. Na TEG baseada no isobutano, ele é compatível com o primeiro coeficiente de Townsend do dióxido de carbono para campos acima de 170 Td. Já o parâmetro na mistura com n-butano é intermediário entre os valores obtidos para o dióxido de carbono e o nitrogênio. Os resultados experimentais, disponíveis em forma tabular, foram comparados com os simulados utilizando o programa Magboltz 2, evidenciando boa concordância dentro da incerteza experimental. / Gaseous microdosimeters usually employ a Tissue-equivalent Gas (TEG), made of a hydrocarbon, carbon dioxide and nitrogen, in order to make similar the stopping power in this mixture and in the human soft tissue. Notwithstanding, regardless the chosen hydrocarbon, both theoretical and experimental data on the first Townsend ionization coefficient (α) in this mixtures are rare, even though the first TEG, which methane is the most abundant gas, was proposed in 1956 by Rossi and Failla and it has been widely employed since then. In this work, data on the parameter α in TEGs based on methane (CH4 64.4%, CO2 32.4%, and N2 3.2%) and butanes isomers (C4H10 51.4%, CO2 42.3% e N2 6.3%) are presented for the first time in planar geometry in the gas density-normalized electric field (E/N) range between 100 290 Td (1 Td = 10-21 V.m2). The adopted method is based on the Pulsed Townsend Technique, where the first Townsend coefficient can be determined by comparing the electric current in the avalanche mode and the primary ionization current, produced by an nitrogen laser beam incidence in a metallic electrode (cathode) of a parallel plate chamber, which the anode is a resistive electrode (ρ=2×1010Ω.m). The experimental setup, previously operated only at atmospheric pressure, was adapted to work also at low pressure (120 hPa), in order to increase the investigated E/N range. The validation of both method and detection system modifications was made by employing three TEGs components, nitrogen, carbon dioxide and methane, whose transport parameters are extensively studied. The parameter in the methane-based TEG follows the behavior observed in pure methane. In the isobutane-based TEG, it is compatible with the first Townsend coefficient in carbon dioxide for E/N above 170 Td. The parameter in the n-butane-based TEG lies between the obtained values of in carbon dioxide and nitrogen. The experimental results, included in tabular form, agree with those from Magboltz 2 simulations within the experimental uncertainties.
96

Nova estratégia para análise de contaminantes emergentes em águas residuais industriais por espectrometria de massas ambiente (PSI-MS) / A new strategy for analysis of emerging contaminants in industrial residual waters by ambient mass spectrometry (PSI-MS)

Rodrigues, Marcella Ferreira 28 February 2018 (has links)
Submitted by Franciele Moreira (francielemoreyra@gmail.com) on 2018-04-04T11:53:17Z No. of bitstreams: 2 Dissertação - Marcella Ferreira Rodrigues - 2018.pdf: 1869503 bytes, checksum: 8b0fc83d8e1366a8a5952aa48164bfd3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-04-04T13:25:36Z (GMT) No. of bitstreams: 2 Dissertação - Marcella Ferreira Rodrigues - 2018.pdf: 1869503 bytes, checksum: 8b0fc83d8e1366a8a5952aa48164bfd3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-04-04T13:25:36Z (GMT). No. of bitstreams: 2 Dissertação - Marcella Ferreira Rodrigues - 2018.pdf: 1869503 bytes, checksum: 8b0fc83d8e1366a8a5952aa48164bfd3 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-02-28 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Water is an essential natural resource for life that is compromised by the release of emerging contaminants, including synthetic hormones. These compounds can be released directly through industrial effluents and indirectly through domestic sewage. Monitoring emergent contaminants (ECs) in the aquatic environment has become a priority as they pose risks to human health and the environment because of their ability to deregulate the endocrine system. Thus, verification analyzes of the emerging contaminants produced by the pharmaceutical industries are required. The most common analytical methods for analysis of this class of compounds involve the use of liquid or gas chromatography coupled to tandem mass spectrometry (MS / MS) with procedures for the preparation of long samples and long chromatographic runs. In this study, a methodology was developed for the analysis of emerging contaminants in raw and treated industrial wastewater from a local industry's hormone production line by an environmental ionization technique known as Paper Spray Ionization (PSI). Here, we have proposed an analytical approach based on the use of waxed papers. Analyzes of the synthetic hormones levonorgestrel and algestone acetophenide occurred by adding the sample to a triangular paper that was moistened with methanol solution (0.1% formic acid). The paper was fixed at the input of the mass spectrometer through a metal clip which provided a voltage to the paper. The analytical curves presented a linear correlation coefficient above 0.99. For the hormone levonorgestrel the intra-day and inter-day precision ranged from 0.5 to 5.3%, accuracy ranged from -7.0 to 4.2% while recovery ranged from 82.2 to 101.3%. For the hormone algestone acetophenide the intra-day and inter-day precision ranged from 0.9 to 10.7%, accuracy ranged from -7.7 to 8.9% while recovery ranged from 88.4 to 101.6%. The levonorgestrel hormone was also analyzed with the classic LC-MS method, showing consistent results between the two approaches, thus confirming the reliability of the proposed method. / A água é um recurso natural essencial para vida que ultimamente está comprometido pela descarga de contaminantes emergentes, dentre os quais, hormônios sintéticos. Esses compostos podem ser lançados diretamente através de efluentes industriais e indiretamente através de esgoto doméstico. O monitoramento de contaminantes emergentes (ECs) no ambiente aquático tem se tornado uma prioridade, visto que eles apresentam riscos para a saúde humana e para meio ambiente devido a sua capacidade de desregular o sistema endócrino. Dessa forma, é necessário análises de verificação dos contaminantes emergentes produzidos pelas indústrias farmacêuticas. Os métodos analíticos mais comuns para análises dessa classe de compostos envolvem o uso de cromatografia líquida ou gasosa, acoplado a espectrometria de massas tandem (MS/MS) com procedimentos de preparos de amostras demorados e longas corridas cromatográficas. Neste trabalho desenvolveu-se uma metodologia para análise de contaminantes emergentes em água residual industrial bruta e tratada de uma linha de produção de hormônios de uma indústria local, por uma técnica de ionização ambiente conhecida como Paper Spray Ionization (PSI), cuja principal vantagem é o preparo mínimo de amostra. Neste trabalho, a técnica de PSI com papel contendo barreiras de parafinas foi empregada para análise de hormônios em águas residuárias. As análises dos hormônios sintéticos levonorgestrel e algestona acetofenida ocorreram através da adição da amostra sobre um papel triangular que foi umedecido com solução de metanol (0,1% de ácido fórmico). O papel foi fixado na entrada do espectrômetro de massas através de um clipe metálico que forneceu uma voltagem ao papel. As curvas analíticas apresentaram coeficiente de correlação linear acima de 0,99. Para o hormônio levonorgestrel a precisão intra-dias e inter-dias variou de 0,5 a 5,3%, a exatidão variou de -7,0 a 4,2% enquanto a recuperação variou de 82,2 a 101,3%. Para o hormônio algestona acetofenida a precisão intra-dias e inter-dias variou de 0,9 a 10,7%, a exatidão variou de -7,7 a 8,9% enquanto a recuperação variou de 88,4 a 101,6%. O hormônio levonorgestrel também foi analisado com o método clássico LC-MS, mostrando resultados consistentes entre as duas abordagens, confirmando assim a confiabilidade do método proposto.
97

Medidas do primeiro coeficiente de Townsend de ionização em misturas gasosas utilizadas em microdosimetria / Measurements of the first Townsend ionization coefficient in gaseous mixtures employed in microdosimetry

Anna Raquel Petri 17 April 2017 (has links)
Microdosímetros gasosos geralmente empregam uma mistura gasosa equivalente ao tecido humano mole (Tissue-equivalent Gas TEG), composta de um hidrocarboneto, dióxido de carbono e nitrogênio, de forma que o poder de freamento na mistura e no tecido sejam semelhantes. Entretanto, independentemente do hidrocarboneto adotado, dados tanto teóricos como experimentais do primeiro coeficiente de Townsend de ionização (α) nestas misturas são raros, ainda que a primeira TEG, cujo metano é o gás majoritário, tenha sido proposta em 1956 por Rossi e Failla e continue sendo amplamente utilizada. Neste trabalho, dados do parâmetro α em TEGs baseadas no metano (CH4 64,4%, CO2 32,4% e N2 3,2%) e nos isômeros do butano (C4H10 51,4%, CO2 42,3% e N2 6,3%) são apresentados pela primeira vez em geometria planar para a faixa de campo elétrico normalizado pela densidade do gás (E/N) entre 100 290 Td (1 Td = 10-21 V.m2). O método de medidas adotado baseia-se na técnica de Townsend pulsada, onde o primeiro coeficiente de Townsend pode ser determinando comparando a corrente elétrica no regime de avalanche e a corrente de ionização primária gerada pela incidência de um feixe de laser de nitrogênio em um eletrodo metálico (catodo) de uma câmara de geometria planar, sendo o anodo um eletrodo de alta resistividade (ρ=2×1010Ω.m). O aparato experimental, até então operado apenas em pressão atmosférica, foi modificado para também trabalhar em baixa pressão (120 hPa), de modo a aumentar a faixa de E/N investigada. A validação do método e das alterações do sistema de detecção foi realizada utilizando os três gases componentes das TEGs cujos parâmetros de transporte são amplamente estudados: o nitrogênio, o dióxido de carbono e o metano. Observou-se que o parâmetro na TEG com metano assemelha-se com os valores determinados para o metano puro. Na TEG baseada no isobutano, ele é compatível com o primeiro coeficiente de Townsend do dióxido de carbono para campos acima de 170 Td. Já o parâmetro na mistura com n-butano é intermediário entre os valores obtidos para o dióxido de carbono e o nitrogênio. Os resultados experimentais, disponíveis em forma tabular, foram comparados com os simulados utilizando o programa Magboltz 2, evidenciando boa concordância dentro da incerteza experimental. / Gaseous microdosimeters usually employ a Tissue-equivalent Gas (TEG), made of a hydrocarbon, carbon dioxide and nitrogen, in order to make similar the stopping power in this mixture and in the human soft tissue. Notwithstanding, regardless the chosen hydrocarbon, both theoretical and experimental data on the first Townsend ionization coefficient (α) in this mixtures are rare, even though the first TEG, which methane is the most abundant gas, was proposed in 1956 by Rossi and Failla and it has been widely employed since then. In this work, data on the parameter α in TEGs based on methane (CH4 64.4%, CO2 32.4%, and N2 3.2%) and butanes isomers (C4H10 51.4%, CO2 42.3% e N2 6.3%) are presented for the first time in planar geometry in the gas density-normalized electric field (E/N) range between 100 290 Td (1 Td = 10-21 V.m2). The adopted method is based on the Pulsed Townsend Technique, where the first Townsend coefficient can be determined by comparing the electric current in the avalanche mode and the primary ionization current, produced by an nitrogen laser beam incidence in a metallic electrode (cathode) of a parallel plate chamber, which the anode is a resistive electrode (ρ=2×1010Ω.m). The experimental setup, previously operated only at atmospheric pressure, was adapted to work also at low pressure (120 hPa), in order to increase the investigated E/N range. The validation of both method and detection system modifications was made by employing three TEGs components, nitrogen, carbon dioxide and methane, whose transport parameters are extensively studied. The parameter in the methane-based TEG follows the behavior observed in pure methane. In the isobutane-based TEG, it is compatible with the first Townsend coefficient in carbon dioxide for E/N above 170 Td. The parameter in the n-butane-based TEG lies between the obtained values of in carbon dioxide and nitrogen. The experimental results, included in tabular form, agree with those from Magboltz 2 simulations within the experimental uncertainties.
98

Análise de sistemas de aterramento com hastes concretadas submetidos a correntes impulsivas.

BEZERRA, Gabriel Vidal Negreiros. 25 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-25T17:58:53Z No. of bitstreams: 1 GABRIEL VIDAL NEGREIROS BEZERRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 5032226 bytes, checksum: 900940f480110db5450f19583af7d19d (MD5) / Made available in DSpace on 2018-04-25T17:58:53Z (GMT). No. of bitstreams: 1 GABRIEL VIDAL NEGREIROS BEZERRA – DISSERTAÇÃO (PPGEE) 2017.pdf: 5032226 bytes, checksum: 900940f480110db5450f19583af7d19d (MD5) Previous issue date: 2017-03-30 / CNPq / Neste trabalho é realizada uma avaliação da resposta impulsiva de aterramento com haste concretada, considerando o efeito da ionização do solo. Para isso, o aterramento foi representado e simulado utilizando uma ferramenta computacional de simulação em três dimensões por meio do método dos elementos finitos. A representação computacional, bem como a validação da mesma, foi feita tomando-se como base dados experimentais apresentados na literatura. O fenômeno da ionização do solo foi implementado ponto a ponto, utilizando o equacionamento do modelo dinâmico de ionização do solo, possibilitando que aterramentos com diferentes formatos geométricos sejam avaliados. Avaliou-se a impedância transitória de uma haste concretada padronizada para solos com diferentes resistividades. Além disso, procedeu-se com uma análise da resposta impulsiva da haste concretada para diferentes parâmetros geométricos, a saber: raio do concreto envolvente, comprimento vertical da haste concretada, comprimento vertical do concreto envolvente e profundidade da haste concretada em relação ao nível do solo. Por fim, propõem-se limites práticos e sugestões de dimensões para a haste concretada, de forma que a reposta impulsiva seja otimizada. / In this research, was performed an impulsive response evaluation of concrete encased groundings, considering de soil ionization effect. In order to achive this, the grouding was represented and simulated in three dimensions using a finite element method software. The computational representation and validation were performed using experimental data presented in the literature. The soil ionization effect was implemented in a point form, allowing evaluate groudings with different geometric formats. It was studied the transient impedance of a standard concrete encased rod placed in soils with different resistivity values. Furthermore, was performed a transient response analysis for different geometric parameters of the concrete encased rod, namely: the concrete radius, the vertical length of the concrete encased rod, the vertical length of the concrete encased rod, the surrounding concrete and the depth of the concrete encased rod in relation to the soil surface. Finally, practical limits and suggested dimensions for the concrete encased rod are proposed, in order to optimize the impulse response.
99

Desenvolvimento de fontes radioativas seladas imobilizadas em resina epóxi para verificação de detectores utilizados em Medicina Nuclear / Development of sealed radioactive sources immobilized in Epoxy resin for verification of detectors used in nuclear medicine

Rodrigo Tiezzi 04 February 2016 (has links)
As fontes radioativas seladas são usadas na verificação de detectores de câmara de ionização, os quais medem a atividade dos radioisótopos usados nas mais diversas áreas, como na Medicina Nuclear. A medida da atividade dos radioisótopos deve ser feita com exatidão, pois será administrada em um paciente. Para garantir o adequado funcionamento dos detectores de câmara de ionização, são estipulados ensaios normatizados pela Agência Internacional de Energia Atômica (IAEA) e a Comissão Nacional de Energia Nuclear (CNEN) utilizando-se fontes radioativas seladas de Bário-133, Césio-137 e Cobalto-57. Os testes avaliam a exatidão, precisão, reprodutibilidade e linearidade da resposta do equipamento. O foco deste trabalho foi o estudo e o desenvolvimento dessas fontes radioativas padrão de Bário-133, Césio-137 e Cobalto-57, utilizando um polímero, no caso resina epóxi comerciais do tipo éter diglicidílico do bisfenol A e um agente de cura a base de poliamina modificada da dietilenotriamina ,para imobilizar o material radioativo. A matriz polimérica apresenta a função primordial de fixar e imobilizar o conteúdo radioativo não permitindo seu vazamento dentro dos limites técnicos exigidos pelas normas de proteção radiológica no quesito de características de uma fonte selada e, adicionalmente, ter a capacidade de reter a emanação de quaisquer gases que venham a se formar durante o processo de fabricação e do período de vida útil deste artefato. O processo de manufatura de uma fonte selada padrão consiste no envasamento, em um frasco de geometria padronizada, de uma quantidade, em volume fixo, de uma matriz polimérica no interior da qual é adicionada e dispersada homogeneamente uma quantidade precisa e exata em atividade de um material radioativo padrão. Nesse sentido, realizou-se um estudo para a escolha da resina epóxi, analisando suas características e propriedades. Foram realizados estudos e testes, verificando a máxima miscibilidade da resina com a água (solução ácida, simulando as condições da solução radiativa), perdas de propriedades mecânicas e térmicas, bem como o controle de dose radioativa para a completa cura (irradiadores de cobalto).Foram produzidas fontes de césio-137 e bário-133, realizou-se testes para determinação do grau de homogeneidade na dispersão do material radioativo na matriz e testes de imersão das fontes seladas produzidas para verificar a estanqueidade do sistema desenvolvido, obtendo um resultado satisfatório de acordo com as normas. Analisando todos os resultados obtidos, as fontes seladas podem ser confeccionadas em matriz epóxi DGEBA e endurecedor poliamínico DETA modificado, desde que a quantidade de material radioativo, na forma de solução ácida, adicionado à composição não ultrapasse um teor de 20%. A cura da resina epóxi pode ser melhorada em relação a ambiente, com uso da irradiação desde que seja exposta a uma dose ao redor de 33 kGy durante a cura. Nos testes de estanqueidade, verificou-se que as fontes são estanques, as medições da atividade da água utilizada nos testes mostraram um valor inferior a 185 Bq (de acordo com a International Standard Organization- Radiation protection sealed radioactive sources - ISO 9978), comprovando a eficiência da resina epóxi como material para selar o material radioativo. Tendo a finalidade de criar uma tecnologia nacional capaz de suprir a demanda deste produto no mercado interno e atingir excelência em qualidade através da acreditação e certificação do produto junto aos órgãos competentes. / The radioactive sealed sources are used in verification ionization chamber detectors, which measure the activity of radioisotopes used in several areas, such as in nuclear medicine. The measurement of the activity of radioisotopes must be made with accuracy, because it is administered to a patient. To ensure the proper functioning of the ionization chamber detectors, standardized tests are set by the International Atomic Energy Agency (IAEA) and the National Nuclear Energy Commission using sealed radioactive sources of Barium-133, Cesium-137 and Cobalt-57. The tests assess the accuracy, precision, reproducibility and linearity of response of the equipment. The focus of this work was the study and the development of these radioactive sources with standard Barium-133 and Cesium-137, using a polymer, in case commercial epoxy resin of diglycidyl ether of bisphenol A (DGEBA) and a curing agent based on modified polyamine diethylenetriamine (DETA), to immobilize the radioactive material. The polymeric matrix has the main function of fix and immobilize the radioactive contents not allowing them to leak within the technical limits required by the standards of radiological protection in the category of characteristics of a sealed source and additionally have the ability to retain the emanation of any gases that may be formed during the manufacture process and the useful life of this artifact. The manufacturing process of a sealed source standard consists of the potting ,into bottle standardized geometry, in fixed volume of a quantity of a polymeric matrix within which is added and dispersed homogeneously to need and exact amount in activity of the radioactive materials standards. Accordingly, a study was conducted for the choice of epoxy resin, analyzing its characteristics and properties. Studies and tests were performed, examining the maximum miscibility of the resin with the water (acidic solution, simulating the conditions of radioactive solution), loss of mechanical and thermal properties, as well as the radioactive dose control for complete curing (cobalt irradiators). For this work was produced a sources of barium-133 and cesium -137,tests were conducted to determination the degree of homogeneity in the dispersion of the radioactive material in the matrix and immersion tests of sealed sources produced to verify the leakage (ISO 9978) of the developed system, occurring obtaining a satisfactory result. With the purpose of creating a national technology able to meet the demand of this product in the domestic market and achieve excellence in quality through accreditation and certification of the product by the appropriate bodies.
100

Avaliação da glicosilação não enzimática (glicação) sobre a fosfolipases A2 secretórias pró-inflamatórias isoladas de venenos de serpentes / Evaluation of non enzymatic glycosylation (glycation) on phospholipase A2 secretory pro-inflammatory isolated from snake venoms

Oliveira, Simone Cristina Buzzo 02 August 2011 (has links)
Orientador: Marcos Hikari Toyama / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-17T12:20:31Z (GMT). No. of bitstreams: 1 Oliveira_SimoneCristinaBuzzo_D.pdf: 2257171 bytes, checksum: dafe56777caf52fdf6e83be317bb28f9 (MD5) Previous issue date: 2011 / Resumo: O objetivo deste trabalho foi avaliar o efeito de glicações sobre a PLA2 secretórias isoladas do veneno das serpentes Crotalus durissus collilineatus e Bothrops jararacussu. A técnica de MALDI-TOF foi usado para comprovar a glicação dos carboidratos nas PLA2: a PLA2 de Cdcolli apresentou glicação a 6 moléculas de D-Glicose e de 5 moléculas de D-Lactose, mas aparentemente não houve glicação com nenhuma molécula de D-Galactose; a BthTX-I apresentou glicação com 5 moléculas de D-Glicose, 1 molécula de D-Galactose e 4 moléculas de D-Lactose; a BthTX-II apresentou ligação a 6 moléculas de D-Glicose, a 1 molécula de D-Galactose e a 4 moléculas de D-Lactose; além disso, a dimerização das PLA2 não ocorreu. A glicação da PLA2 de Cdcolli com D-Glicose e D-Lactose aumentou sua atividade enzimática e mudou seu perfil alostérico, da mesma forma, esses carboidratos aumentaram a ação edematogênica e anularam a atividade citotóxica dessa PLA2. No entanto, D-Lactose e D-Glicose diminuíram o efeito miotóxico e modificaram o perfil de agregação plaquetária da PLA2 de Cdcolli nativa, embora apenas a D-Lactose tenha diminuído significantemente a agregação. A glicação de BthTX-I a D-Glicose e D-Galactose diminuiu sua ação edematogênica, e sua glicação aos carboidratos testados diminuiu seu efeito miotóxico. A glicação de BthTX-II a D-Lactose diminuiu sua atividade enzimática, a ação edematogência foi diminuída pela glicação a todos os carboidratos, enquanto a glicação a D-Glicose e D-Galactose diminuíram seu efeito miotóxico. A fluorescência intrínseca apresenta mudanças na estrutura terciária de BthTX-I e BthTX-II após a glicação e o dicroísmo circular sugere modificação na estrutura secundária da PLA2 de Cdcolli. Além disso, a modelação da PLA2 de Cdcolli apresentou várias regiões da proteína livres onde pode estar ocorrendo a glicação. Esse resultados sugerem que a glicação modifica a estrutura da PLA2, modulando de forma diferente a atividade enzimática e o efeito biológico, possivelmente a mudança estrutural ou mesmo os carboidratos ligados a estrutura da PLA2 estão modificando sua afinidade a receptores de membrana. Adicionalmente, os resultados evidenciam que os sítios responsáveis pelas atividades enzimática e biológica estão em lugares diferentes dentro da estrutura da PLA2 / Abstract: The objective of this work was evaluate the effect of glycations in the secretory PLA2 isolated from Crotalus durissus collilineatus (Cdcolli) and Bothrops jararacussu (BthTX-I, catalytic inative K49 and BthTX-II, catalytic active D49) rattlesnake venom. The MALDI-TOF technic was used to test the glycation in the PLA2: Cdcolli showed glycation to 6 molecules of D-Glucose and 5 molecules of D-Lactose, but no glycation to D-Galactose; the BthTX-I showed glycation to 5 molecules of D-Glucose, 1 molecule of D-Galactose and 4 molecules of D-Lactose; the BthTX-II showed glycation to 6 molecules of D-Glucose, 1 molecule of D-Galactose and 4 molecules of D-Lactose. The glycation of PLA2 from Cdcolli to D-Glucose and D-Lactose increased the enzymatic activity and changed its alosteric profile, in the same way, theses carbohydrates increased the edematogenic effect and annuled the citotoxic activity. However, D-Lactose and D-Glucose decreased the miotoxic effect and changed the platelet aggregation profile of native PLA2, although only D-Lactose had decreased the aggregation. The glycation of BthTX-I to D-Glicose and D-Galactose decreased the edematogenic effect and its glycation to all carbohydrates decreased the miotoxic effect. The glycation of BthTX-II to D-Lactose decreased its enzymatic activity; the edematogenic effect was decreased by the glycation to all the carbohydrates, while the glycation to D-Glucose and D-Galactose decreased the miotoxic effect. The intrinsec fluorescence shows changes in the terciary structure of BthTX-I and BthTX-II after glycation and the circular dichroism suggests modification in the secundary structure of glycated PLA2 from Cdcolli. Besides, the structure modelation shows many free areas in the PLA2 from Cdcolli, where the glycation can be happening. Theses results suggest that the glycation modifies the structure of PLA2, modulating in a different way the enzymatic and the biologic activity; probably the structure changes or even the linked carbohydrates to the PLA2 structure are modifying the affinity for membrane receptors. Additionally, the results show that the enzymatic and biological sites are in different areas in the PLA2 structure. / Doutorado / Bioquimica / Doutor em Biologia Funcional e Molecular

Page generated in 0.0315 seconds