Avaliação da resistência de união proporcionada por diferentes tipos de cimentos resinosos em pilares híbridos de zircônia

Lacerda, Gabriel Pinheiro 27 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-05T13:56:21Z No. of bitstreams: 1 gabrielpinheirolacerda.pdf: 1840814 bytes, checksum: 711c6aedc66cee4634cf4c1d2a8d1317 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-07T15:38:01Z (GMT) No. of bitstreams: 1 gabrielpinheirolacerda.pdf: 1840814 bytes, checksum: 711c6aedc66cee4634cf4c1d2a8d1317 (MD5) / Made available in DSpace on 2016-06-07T15:38:01Z (GMT). No. of bitstreams: 1 gabrielpinheirolacerda.pdf: 1840814 bytes, checksum: 711c6aedc66cee4634cf4c1d2a8d1317 (MD5) Previous issue date: 2015-04-27 / O propósito deste estudo foi avaliar in vitro, a resistência de união entre os constituintes dos pilares híbridos de zircônia, comparando diferentes tipos de cimentos resinosos. Para a realização do presente estudo foram confeccionadas trinta peças de zircônia com formato anatômico de primeiro molar inferior direito. Estas foram divididas em três grupos de acordo com os cimentos resinosos a serem utilizados para cimentá-las sobre bases metálicas de titânio: Grupo A- cimento auto adesivo de dupla ativação, Grupo B- cimento de dupla ativação convencional e Grupo C- cimento quimicamente ativado. Posteriormente ao processo de cimentação, os 30 corpos de prova foram armazenados em água destilada por 24 horas em temperatura ambiente e em seguida, foram submetidos à ciclagem térmica em equipamento específico sendo submetidos a banhos em 5o C e 55o C, com 30 segundos de permanência em cada banho, tempo de deslocamento de 2 segundos, totalizando 6.000 ciclos. Os testes de ciclagem mecânica foram realizados com os corpos de prova imersos em água destilada a 37o C, com carga de 100N, frequência de 2Hz e 200.000 ciclos. Após os testes termomecânicos, os espécimes foram submetidos a testes de tração na máquina de ensaio universal EMIC DL 2000. Os valores de resistência de união foram obtidos em Quilograma Força (Kgf) para cada espécime. Os dados obtidos pelo ensaio de tração foram submetidos ao teste ANOVA, com nível de significância de 5%. Anterior a realização deste teste, os dados foram verificados quanto a sua normalidade e homocedasticidade pelos testes de Shapiro-Wilk e Bartlett, respectivamente. Por meio de um estereomicroscópio verificou-se que o modo de falha de cimentação do tipo adesiva, entre cimento resinoso e superfície de zircônia, ocorreu em todos os corpos de provas. Conclui-se que os diferentes tipos de cimentos resinosos testados neste estudo se comportaram de maneira eficiente na cimentação das duas peças dos pilares híbridos de zircônia. / Objective: The purpose of this study was to evaluate in vitro by means of tensile test, the bond strength of the constituents of zirconia abutments of two pieces in unit restorations on implants with prosthetic connections cone morse type, comparing three different types of cements resinous. Materials and Methods: Thirty zirconia pieces with the mandibular first molar format were divided into three groups according to the cement to be used to cement them on metal titanium bases: Group A- Relyx U200, Group B- Panavia F 2.0 and Group C- Multilink. Subsequently the process of cementing, the 30 specimens were stored in distilled water for 24 hours at room temperature and then were submited to thermal cycling in specific equipment undergoing baths in 5°C and 55°C, with 30 seconds remaining in each bath, 2 seconds travel time, totaling 6.000 cycles. The mechanical cycling tests were performed with the samples immersed in distilled water at 37°C, with 100N load, frequency of 2Hz and 200.000 cycles. After the thermomechanical tests, the specimens were subjected to tensile tests in a universal testing machine EMIC DL 2000. The bond strength values were supplied by the computer of the testing machine, and obtained in kilogram force (Kgf) individually for each specimen. The data obtained hair tensile test were submitted when ANOVA test, with significance level of 5 %. Previous conducting this test, the were data are checked for normality and homocedasticity those testicles - Wilk Shapiro and Bartlett, respectivamente. By means of hum stereomicroscope has been found that the adhesive cementation failure mode to type, resin cement and surface zirconia occurred in all the evidence of bodies. It is concluded that the three types of resin cements tested in this study behaved way efficient cementation of two parts of hybrid pillars of zirconia.
12

Desarrollo de recubrimientos híbridos osteoinductores para implantes dentales

Hernández Escolano, Miriam 09 March 2012 (has links)
En la actualidad, en el desarrollo de implantes metálicos y, en particular el de los dentales, se necesitan métodos innovadores que permitan desarrollar nuevos procesos y materiales con mayor velocidad de osteointegración, para conseguir una unión hueso-implante óptima en todo tipo de pacientes, incluso en aquellos donde el uso de implantes dentales se desaconseja por tener mermada la capacidad para la regeneración ósea. El titanio y algunas de sus aleaciones son materiales reconocidos como biocompatibles y los más empleados para la fabricación de implantes dentales. Sin embargo, en algún tipo de pacientes, los tiempos necesarios para la osteointegración son más elevados de lo deseable. Así pues, poder reducir los tiempos de cirugía requeridos en este tipo de operaciones, así como poder abarcar un mayor abanico de posibles pacientes tiene una gran relevancia clínica. Una vía innovadora e incipiente para solucionar este inconveniente consiste en desarrollar nuevos recubrimientos osteoinductores que mejoren las propiedades de los implantes metálicos dentales. El objetivo principal de esta Tesis Doctoral se centra en desarrollar recubrimientos con propiedades osteoinductoras para implantes dentales metálicos que mejoren su osteointegración, de forma que se reduzcan los tiempos para su integración. Se pretende dotar además a estos recubrimientos de una propiedad añadida, como es la capacidad de liberación de agentes terapéuticos cuando la situación lo requiera, evitando, por un lado las infecciones o procesos inflamatorios y, por otro lado, la ingesta de medicamentos por cualquier otra vía. Para alcanzar estos objetivos, se propone la preparación de un recubrimiento híbrido orgánico-inorgánico obtenido mediante procesos de tipo sol-gel. La idea base subyacente en los desarrollos efectuados se centra en conseguir que el contacto del implante metálico con los tejidos vivos pueda establecerse a través de un material degradable con el tiempo que potencie la adhesión y proliferación celular, y la posterior mineralización. / Hernández Escolano, M. (2012). Desarrollo de recubrimientos híbridos osteoinductores para implantes dentales [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/14981
13

[en] RESISTANCE ANALYSIS OF FIXED ZIRCONIA BRIDGES APPLIED IN SCREWED DENTAL PROSTHESIS / [pt] ANÁLISE DA RESISTÊNCIA DE PONTES FIXAS EM ZIRCÔNIA APLICADAS EM PRÓTESES DENTÁRIAS APARAFUSADAS

JOSE ALEX GONCALVES DE GALIZA 10 March 2015 (has links)
[pt] Esse trabalho teve como objetivo principal avaliar a resistência à falha da infraestrutura de uma prótese parcial fixa em zircônia de três elementos e aparafusada sobre implantes, através de análise de tensões por elementos finitos e determinação da resistência à fadiga da estrutura. Como objetivo secundário, foram avaliadas as distribuições das tensões nos demais componentes da prótese. Na análise de tensões, dois modelos distintos foram gerados, sendo o primeiro com prótese, implantes e parafusos similares àqueles adotados na clínica odontológica. Um segundo modelo, usado como controle, adotou uma geometria simplificada. As cargas mastigatórias foram aquelas usuais da literatura especializada e a análise por elementos finitos foi realizada através do programa Ansys Workbench 14.5. Os resultados das distribuições de tensões mostraram semelhanças entre os dois modelos, com pequenas variações relacionadas às geometrias empregadas. As tensões calculadas ficaram abaixo dos limites de resistência mecânica da zircônia e das ligas de titânio. No cálculo da vida em fadiga da prótese de zircônia um modelo analítico foi adotado prevendo uma vida infinita para o componente. / [en] The main goal of this work was to evaluate the failure resistance of a zirconia fixed partial denture of three elements screwed on implants by means of a finite element stress analysis and the determination of the fatigue strength of the structure. As a secondary objective, the stress distributions in the other components of the prosthesis were evaluated. In order to promote the stress analysis, two different models were generated, the first making use of prosthesis, implants and screws similar to those adopted in the dental clinic. A second model, used as control, adopted a simplified geometry. The masticatory loads were those presented usually in the literature and finite element analysis was performed making use of Ansys Workbench 14.5 program. The stress distribution results showed similarity in both models, with small variations related to the adopted geometries. The calculated stresses were smaller than the ultimate strength of the zirconia and titanium alloys. Concerning the fatigue life of the zirconia prosthesis an analytical model was adopted and estimated an infinite life for the component.
14

Análise da liberdade rotacional de pilares para prótese unitária de hexágono externo submetidos à ciclagem mecânica / Evaluation of abutment rotational freedom of external hexagon single implat restoration after mechanical cycling

Piantino, Marcela Caffarena Junqueira 30 August 2010 (has links)
A estabilidade da prótese na junção parafusada está diretamente relacionada ao seu grau de adaptação e assentamento bem como à pré-carga que é gerada para unir os componentes. O afrouxamento e/ ou fratura do parafuso do pilar e também a desadaptação rotacional na interface implante/ pilar têm sido relatados como os maiores problemas encontrados em reabilitações unitárias parafusadas, em especial áreas de pré-molares e molares. Desta forma, o objetivo deste estudo foi avaliar a liberdade rotacional (LR) de 20 pilares protéticos tipo UCLA calcináveis (10 totalmente plásticos e 10 com a base usinada em Tilite - Neodent Implante Osteointegrável), fundidos em liga de NiCr e Tilite, respectivamente, sobre 10 implantes de hexágono externo (Hexágono Externo, HE Neodent Implante Osteointegrável) para próteses unitárias e, também o torque de afrouxamento do parafuso do pilar, submetidos à ciclagem mecânica. Um dispositivo foi fabricado para medir os ângulos de liberdade rotacional entre os hexágonos de implante e pilar em três diferentes tempos: antes e após o processo de fundição e depois da ciclagem mecânica. Os grupos foram classificados de acordo com as leituras de LR: (1) pilares novos + implantes novos; (2) pilares fundidos + implantes novos; (3) pilares fundidos + implantes, ambos ciclados; (4) outros pilares novos + implantes ciclados e (5) os mesmos pilares após fundição + implantes ciclados. Foram medidas as distâncias entre os lados e vértices do hexágono externo dos implantes e interno dos pilares. Para a realização da ciclagem mecânica, foi utilizada uma máquina de ensaio cuja carga média aplicada foi de 120 N em sentido axial, com componente oblíquo, a uma freqüência de 101 ciclos por minuto (1,8 Hz), durante 500.000 ciclos. O torque de aperto dos parafusos de fixação foi de 32 N.cm e o de afrouxamento mensurado após fadiga. Atestada a normalidade da amostra aplicou-se o teste t de Student para comparações em par (p<0,05). Os resultados encontrados foram: para LR (em graus): Grupo Tilite (1) 2,930 ± 0,273; (2) 4,506 ± 2,448; (3) 5,126 ± 2,885; (4) 3,229 ± 0,235; (5) 2,813 ± 0,406; Grupo NiCr: (1) 4,684 ± 0,788; (2) 3,21 ± 1,370; (3) 3,818 ± 1,904; (4) 6,029 ± 0,503; (5) 4,421 ± 2,499. A análise estatística revelou que não houve significância entre nenhuma das diferentes leituras de LR tanto para os pilares do grupo NiCr quanto para os do Tilite; todavia, quando a comparação foi feita entre os pilares, houve diferença estatística significativa para as leituras (1) e (4), com maiores valores para os pilares plásticos calcináveis. O destorque para o grupo NiCr foi de 13,26 ± 4,32 N.cm com perda de torque de 41,44% e, para o grupo Tilite de 13,72 ± 7,36 N.cm e perda de torque de 42,88%. Houve expressiva perda de torque para ambos os grupos, porém não houve diferença estatística na comparação entre as ligas. A quantidade de ciclos aplicada não foi suficiente para alterar de forma significativa a LR nos conjuntos implante/ pilar quando avaliados para cada tipo de liga. A aplicação de cargas cíclicas alterou de forma significativa as dimensões dos implantes. / Prosthesis stability is related to misfit and screw joint preload. The screw loosening or fracture and rotational misfit have been related as the major problems in screwed single implant restorations, especially in molar or premolar areas. The aim of this study was to evaluate the rotational freedom and detorque of 20 UCLA type abutment (10 plastic and 10 machined abutments) cast in NiCr and NiCrTi alloys respectively, over 10 external hexagon implants submitted to mechanical cycling. A device was made to measure the rotational freedom between the implant hexagon and abutment in three different times: before and after the cast procedure and after the mechanical cycling. Groups were classified according the rotational misfit register: (1) new abutments + new implants; (2) cast abutments + new implants; (3) cycled cast abutments + cycled implants; (4) new abutments + cycled implants, and, (5) cast abutments + cycled implants. Measurements were made in the sides and vertices of external hexagon of the implants and internal hexagon of the abutments. Specimens were positioned with 30° of inclination in relation to the vertical axis in an eletromechanical machine for mechanical cycling (5.0x105 cycles) using 120N axial load and 1.8 Hz of frequence. The abutment screws were tightened to a torque of 32N.cm and the detorque measurement was registered after mechanical cycling. The rotational freedom results were: NiCrTi groups - (1) 2.930 ± 0.273; (2) 4.506 ± 2.448; (3) 5.126 ± 2.885; (4) 3.229 ± 0.235; (5) 2.813 ± 0.406; and NiCr groups - (1) 4.684 ± 0.788; (2) 3.21 ± 1.370; (3) 3.818 ± 1.904; (4) 6.029 ± 0.503; (5) 4.421 ± 2.499. Statistical analysis (p<0.05) showed that there is not significance among the different rotational freedom of NiCrTi or NiCr abutments; but there is statistically significant difference between (1) and (4) with higher values to the plastic abutments. Detorque of NiCr group was 13.26±4.32N.cm (-41.44%) and to the NiCrTi group was 13.72±7.36N.cm (-42.88%) but there is not statistically significant difference between the alloys. The mechanical cycling did not statistically influence the rotational freedom in the abutment/implant system when evaluated to each alloy but influenced the implant dimension.
15

Análise da liberdade rotacional de pilares para prótese unitária de hexágono externo submetidos à ciclagem mecânica / Evaluation of abutment rotational freedom of external hexagon single implat restoration after mechanical cycling

Marcela Caffarena Junqueira Piantino 30 August 2010 (has links)
A estabilidade da prótese na junção parafusada está diretamente relacionada ao seu grau de adaptação e assentamento bem como à pré-carga que é gerada para unir os componentes. O afrouxamento e/ ou fratura do parafuso do pilar e também a desadaptação rotacional na interface implante/ pilar têm sido relatados como os maiores problemas encontrados em reabilitações unitárias parafusadas, em especial áreas de pré-molares e molares. Desta forma, o objetivo deste estudo foi avaliar a liberdade rotacional (LR) de 20 pilares protéticos tipo UCLA calcináveis (10 totalmente plásticos e 10 com a base usinada em Tilite - Neodent Implante Osteointegrável), fundidos em liga de NiCr e Tilite, respectivamente, sobre 10 implantes de hexágono externo (Hexágono Externo, HE Neodent Implante Osteointegrável) para próteses unitárias e, também o torque de afrouxamento do parafuso do pilar, submetidos à ciclagem mecânica. Um dispositivo foi fabricado para medir os ângulos de liberdade rotacional entre os hexágonos de implante e pilar em três diferentes tempos: antes e após o processo de fundição e depois da ciclagem mecânica. Os grupos foram classificados de acordo com as leituras de LR: (1) pilares novos + implantes novos; (2) pilares fundidos + implantes novos; (3) pilares fundidos + implantes, ambos ciclados; (4) outros pilares novos + implantes ciclados e (5) os mesmos pilares após fundição + implantes ciclados. Foram medidas as distâncias entre os lados e vértices do hexágono externo dos implantes e interno dos pilares. Para a realização da ciclagem mecânica, foi utilizada uma máquina de ensaio cuja carga média aplicada foi de 120 N em sentido axial, com componente oblíquo, a uma freqüência de 101 ciclos por minuto (1,8 Hz), durante 500.000 ciclos. O torque de aperto dos parafusos de fixação foi de 32 N.cm e o de afrouxamento mensurado após fadiga. Atestada a normalidade da amostra aplicou-se o teste t de Student para comparações em par (p<0,05). Os resultados encontrados foram: para LR (em graus): Grupo Tilite (1) 2,930 ± 0,273; (2) 4,506 ± 2,448; (3) 5,126 ± 2,885; (4) 3,229 ± 0,235; (5) 2,813 ± 0,406; Grupo NiCr: (1) 4,684 ± 0,788; (2) 3,21 ± 1,370; (3) 3,818 ± 1,904; (4) 6,029 ± 0,503; (5) 4,421 ± 2,499. A análise estatística revelou que não houve significância entre nenhuma das diferentes leituras de LR tanto para os pilares do grupo NiCr quanto para os do Tilite; todavia, quando a comparação foi feita entre os pilares, houve diferença estatística significativa para as leituras (1) e (4), com maiores valores para os pilares plásticos calcináveis. O destorque para o grupo NiCr foi de 13,26 ± 4,32 N.cm com perda de torque de 41,44% e, para o grupo Tilite de 13,72 ± 7,36 N.cm e perda de torque de 42,88%. Houve expressiva perda de torque para ambos os grupos, porém não houve diferença estatística na comparação entre as ligas. A quantidade de ciclos aplicada não foi suficiente para alterar de forma significativa a LR nos conjuntos implante/ pilar quando avaliados para cada tipo de liga. A aplicação de cargas cíclicas alterou de forma significativa as dimensões dos implantes. / Prosthesis stability is related to misfit and screw joint preload. The screw loosening or fracture and rotational misfit have been related as the major problems in screwed single implant restorations, especially in molar or premolar areas. The aim of this study was to evaluate the rotational freedom and detorque of 20 UCLA type abutment (10 plastic and 10 machined abutments) cast in NiCr and NiCrTi alloys respectively, over 10 external hexagon implants submitted to mechanical cycling. A device was made to measure the rotational freedom between the implant hexagon and abutment in three different times: before and after the cast procedure and after the mechanical cycling. Groups were classified according the rotational misfit register: (1) new abutments + new implants; (2) cast abutments + new implants; (3) cycled cast abutments + cycled implants; (4) new abutments + cycled implants, and, (5) cast abutments + cycled implants. Measurements were made in the sides and vertices of external hexagon of the implants and internal hexagon of the abutments. Specimens were positioned with 30° of inclination in relation to the vertical axis in an eletromechanical machine for mechanical cycling (5.0x105 cycles) using 120N axial load and 1.8 Hz of frequence. The abutment screws were tightened to a torque of 32N.cm and the detorque measurement was registered after mechanical cycling. The rotational freedom results were: NiCrTi groups - (1) 2.930 ± 0.273; (2) 4.506 ± 2.448; (3) 5.126 ± 2.885; (4) 3.229 ± 0.235; (5) 2.813 ± 0.406; and NiCr groups - (1) 4.684 ± 0.788; (2) 3.21 ± 1.370; (3) 3.818 ± 1.904; (4) 6.029 ± 0.503; (5) 4.421 ± 2.499. Statistical analysis (p<0.05) showed that there is not significance among the different rotational freedom of NiCrTi or NiCr abutments; but there is statistically significant difference between (1) and (4) with higher values to the plastic abutments. Detorque of NiCr group was 13.26±4.32N.cm (-41.44%) and to the NiCrTi group was 13.72±7.36N.cm (-42.88%) but there is not statistically significant difference between the alloys. The mechanical cycling did not statistically influence the rotational freedom in the abutment/implant system when evaluated to each alloy but influenced the implant dimension.
16

Isolamento e cultura de células tronco mesenquimais da polpa dental e comparação de implantes dentários para cães estudos / Isolation and culture of stem cells mesenchymal of dental pulp and comparison of dental implants fro dogs studies in vitroin vitro

Aramburú Junior, Jaime Sardá 25 November 2015 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / This work was developed in two stages, described in scientific papers format. The goal of the first article was to adjust the techniques described in the literature for the isolation and culture of dental pulp cells to the physical and economic conditions of the research laboratory where the research was conducted. The methodology of this study was oriented by obtaining the pulp tissue from five deciduous teeth of dogs, which were digested in simple solution collagenase type 1 with positive results for the isolation. The outcome of the study was the isolation and cell culture of dental pulp with a lower cost and with enough cells for use in therapy. In the second study, the objective was to compare the in vitro resistance of dental implants with masticatory force dogs reported in the scientific literature. For materials and methods three different diameters dental implants 3.3mm, 4mm and 5mm were tested for static strength by applying compressive force on them. The result was a direct relationship to the resistance between the diameter and the applied force. Therefore, we can conclude that the method of isolation of dental pulp cells and culture of this study is similar to that described in the literature, but with the simplified methodology. And chewing strength of dogs can vary greatly, therefore we recommend possible the use of dental implants with a larger diameter. / Este trabalho foi desenvolvido em duas etapas, descritas no formato de artigos científicos. O objetivo do primeiro artigo foi ajustar às técnicas descritas na literatura para o isolamento e cultura da polpa dental para as condições físicas e econômicas do laboratório de pesquisa onde foi realizada a mesma. E a metodologia deste estudo foi orientada pela obtenção do tecido pulpar de cinco dentes decíduos de cães, que foram digeridos em solução simples de colagenase tipo 1 com resultados positivos para os isolamentos. O resultado do estudo foi o isolamento e cultura de células da polpa dental a um custo menor e com suficiente de células para utilização em terapia. No segundo estudo, o objetivo foi comparar a resistência in vitro de implantes dentários com cães de força mastigatória relatado na literatura científica. Para os materiais e métodos do estudo três diâmetros diferentes de implantes dental 3,3 mm, 4mm e 5mm foram testados quanto a resistência pela aplicação de força estática de compressão sobre eles. O resultado obtido foi de uma relação direta para a resistência entre o diâmetro e a força aplicada. Por isso, podemos concluir que o método de isolamento e cultura de células da polpa dental deste estudo é semelhante ao descrito na literatura, porém com a metodologia simplificada. E a força mastigatória dos cães pode variar, por isto é recomendado sempre que possível o uso de implante dental de maior diâmetro.
17

Avaliação da sobrecarga em pilares e região periimplantar de implantes cone Morse, ferulizados ou não ferulizados: análise tridimensional em elementos finitos

Magalhães, Guilherme Carminati de 27 February 2015 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / This study evaluated the stress distribution in abutments on Morse taper implants and peri-implantar surrounding bone supporting fixed partial dentures, splinted or non-splinted, under axial and oblique loading. The study simulates by means of Finite Element Analysis the loss of two posterior mandibular elements: 1st premolar and 2nd premolar. For mandible simulation a tridimensional box with Type II bone was simulated. The implant system and abutment were obtained using CAD models transferred by the company. Were used Morse taper Implant Titamax CM-Cortical Ø 3.75mm x 9.0mm and Abutment Pilar CM with 2,5mm height (Neodent, Curitiba, PR, Brazil) divided in two groups according the prosthetic rehabilitation: splinted and non-splinted; subjected to two types of loading: axial simulating functional masticatory contact and oblique simulating parafunctional occlusal contact. The implants were positioned 1.5mm under bone level according manufactures recommendation and the abutments were installed with aid of CAD software. The data were analyzed after dynamic loading of 100N in axial direction in the buccal cusp and the oblique loading (angle of 45o) in the distal-lingual cusp; both on 2nd premolar. The results showed lower tensions for F Group on axial loading for both abutment (77.37MPa) and peri-implantar surrounding bone (118.58MPa); however for NF Group axial loading demonstrated similar values as described previously. The oblique loading promoted higher stress for both abutment (505,67MPa) and peri-implantar surrounding bone (505,67MPa). The crowns splinting promotes lower stress on F Group abutment when compared with NF Group regardless the loading type. The stresses on peri-implantar surrounding bone during occlusal axial loading are similar regardless the surface contact between the prosthesis. / Este trabalho avaliou a distribuição de tensões geradas nos pilares protéticos sobre implantes cone Morse e no osso periimplantar que suportam próteses parciais fixas, ferulizadas ou não ferulizadas, sob carregamento axial e oblíquo. O estudo simulou, por meio de Análise em Elementos Finitos, a perda de dois elementos dentais posteriores inferiores: 1° pré-molar e 2° pré-molar. Para simulação da mandíbula, uma caixa tridimensional com propriedades de osso tipo 2 foi confeccionada. O sistema de implante e pilares foram obtidos por meio de modelos em CAD cedidos pela empresa. O estudo utilizou implantes cone Morse (CM) Titamax CM-Cortical® Ø 3,75mm x 9,0mm e Pilar CM de 2,5mm de altura (Neodent, Curitiba, PR, Brasil) dividido em dois grupos, de acordo com a reabilitação protética: ferulizadas e não ferulizadas, cada modelo foi então submetido a dois tipos de carregamento: axial, simulando contato mastigatório funcional e obliquo, simulando contato oclusal parafuncional. Os implantes foram posicionados 1,5mm abaixo da margem óssea, segundo recomendação do fabricante, e os pilares foram instalados com auxilio de software tipo CAD. Os dados foram analisados após aplicação de carregamento dinâmico com força de 100N em direção axial na cúspide vestibular e o carregamento oblíquo (angulação de 45°) na cúspide distolingual, ambos no 2° pré-molar. Os resultados demonstram menores valores de tensão para o grupo F sob carregamento axial, tanto para o pilar (77,37MPa) quanto para o osso periimplantar (118,58MPa); entretanto, mesmo para o grupo NF o carregamento axial demonstrou valores semelhantes aos descritos anteriormente. O carregamento obliquo gera maiores tensões tanto para o pilar (505,67MPa) quanto para o osso periimplantar (505,67MPa) em ambos os grupos. Conclui-se que a ferulização das coroas gera menor tensão no pilar protético no grupo F quando comparado ao grupo NF independente do carregamento. As tensões a nível ósseo periimplantar, durante carregamento oclusal axial apresentaram-se semelhantes independente do tipo de superfície de contato entre as próteses. / Mestre em Odontologia