• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 851
  • 34
  • 32
  • 32
  • 31
  • 23
  • 9
  • 9
  • 9
  • 7
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 881
  • 881
  • 560
  • 490
  • 219
  • 205
  • 156
  • 118
  • 104
  • 98
  • 87
  • 85
  • 83
  • 81
  • 76
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Regeneração óssea de defeitos circunferenciais criados cirurgicamente ao redor de implantes submersos. Estudo experimental em cães /

Rossi, Fabio. January 2011 (has links)
Orientador: Daniele Botticelli / Banca: Wilson Roberto Poi / Banca: Idelmo Rangel Garcia Júnior / Banca: Márcio de Moraes / Banca: Thaís da Silveira Rodrigues / Resumo: Objetivo: descrever o processo de reparo em defeitos marginais ao redor de implantes submersos 1mm abaixo ou acima da crista óssea. Estudo experimental em cães. Material e Métodos: Em 12 cães labradores, todos os pré-molares inferiores e primeiros molares foram extraídos bilateralmente. Três meses após as extrações, foi realizada a incisão sobre o rebordo e o descolamento dos retalhos de espessura total do lado direito da mandíbula. Foram preparados dois sítios cirúrgicos para instalação de implantes, com a região marginal alargada em 5mm de diâmetro para obtenção de um gap de 0,5 mm na região mesial (defeito pequeno) e um gap de 1,25 mm na região distal (defeito grande). Os parafusos de cobertura foram colocados aos implantes e os retalhos suturados para permitir um processo de cicatrização totalmente submerso. Posteriormente, foram realizados os mesmos procedimentos experimentais no lado esquerdo da mandíbula. O momento da realização dessas cirurgias e as eutanásias foram planejados de forma a se obter biópsias com 5, 10, 20, 30 dias de pósoperatórios. Após a eutanásia, os cortes histológicos foram processados laboratorialmente para análise histomorfométrica. Resultados: Aos 30 dias pós-operatório, os defeitos ósseos apresentaram-se parcialmente preenchidos por osso neoformado em todos os espécimes. A formação óssea ocorreu originando-se a partir da base do defeito e das paredes laterais. Um maior volume de osso neoformado foi observado nos defeitos grandes quando comparado aos pequenos. A maior parte de osso neoformado nos defeitos grandes formou-se entre o décimo e vigésimo dias de pósoperatórios. Entretanto, o contorno do osso neoformado localizou-se a uma distância similar da superfície do implante (aproximadamente 0,4 mm) em ambos os tipos de defeitos, no... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: to describe the healing of marginal defects below or above one millimeter of dimension around submerged implants in a dog model. Material and Methods: In 12 Labrador dogs, all mandibular premolars and first molars were extracted bilaterally. After 3 months of healing, full-thickness flaps were elevated in the edentulous region of the right side of the mandible. Two recipient sites were prepared and the marginal 5 mm were widened to such an extent to obtain, after implant installation, a marginal gap of 0.5 mm at the mesial site (small defect) and of 1.25 mm at the distal site (large defect). Titanium healing caps were affixed to the implants and the flaps were sutured allowing a fully-submerged healing. The experimental procedures were subsequently performed in the left side of the mandible. The timing of the experiments and sacrifices were planned in such a way to obtain biopsies representing the healing after 5, 10, 20, 30 days. Ground sections were prepared and histomorphometrically analyzed. Results: The filling of the defect with newly formed bone was incomplete after one month of healing in all specimens. Bone formation occurred from the base and the lateral walls of the defects. A larger volume of new bone was formed in the large compared to the small defects. Most of the new bone at the large defect was formed between the 10 and the 20-day period of healing. After one month of healing, the outline of the newly formed bone was, however, located at a similar distance from the implant surface (about 0.4 mm) at both defect types. Only minor newly formed bone in contact with the implant, starting from the base of the defects, was seen at the large defects (about 0.8 mm) while a larger amount was detected at the small defects (about 2.2 mm). Conclusion: Marginal defects around titanium... (Complete abstract click electronic access below) / Doutor
162

Distribuição das tensões em próteses protocolo mandibulares com diferentes extensões de cantilever e material de revestimento oclusal /

Medeiros, Rodrigo Antonio de. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Marcelo Ferraz Mesquita / Resumo: Neste estudo objetivamos a avaliação da distribuição de tensões na interface osso/implante, por meio do método da fotoelasticidade, em próteses mandibulares tipos protocolos de Branemark, com diferentes extensões de cantilever, materiais de recobrimento estético e uso de intermediários. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula, contendo cinco implantes 4.0x13 mm hexágono externo (HE) entre os forames mentonianos. Os grupos foram divididos da seguinte forma: Grupo 1 - UCLA e barra metálica; Grupo 2 - UCLA e revestimento oclusal em resina acrílica; Grupo 3 - UCLA e revestimento em cerâmica; Grupo 4 - Intermediário e barra metálica; Grupo 5 - Intermediário e revestimento em resina acrílica; Grupo 6 - Intermediário e revestimento em cerâmica. Com auxílio de uma máquina de ensaio EMIC inicialmente as forças de 70 N foram aplicadas em um ponto anterior, no implante mais posterior e em diferentes extensões de cantilever (até 37,5mm do último implante) na barra metálica e posteriormente nas próteses confeccionadas com barra metálica e revestimento em cerâmica e resina acrílica. Por meio de imagens fotográficas e auxílio do programa Adobe Photoshop CS6 nas imagens obtidas após o teste foi realizada a análise das tensões de acordo com o número de franjas de alta intensidade e de acordo com a concentração e área de distribuição dessas tensões nos grupos testados. Os resultados mostraram um maior número de franjas de alta tensão com o aumento do cantilever, e melhor distribuição das tensões foram para os grupos com as próteses confeccionadas em resina acrílica e para os grupos que continham componente intermediário. Concluímos que o uso de intermediários com próteses protocolo em resina acrílica e a ausência do cantilever tende a apresentar menores números de franjas de alta tensão ao redor dos implantes / Abstract: The aim of this study was to assess the stress distribution, through photoelastic method, on mandibular implant-supported prostheses (Brånemark protocol), associated with different cantilever lengths, aesthetic coating materials and implant abutment. One photoelastic model of an edentulous mandible was made. The model contained five external hexagon implants (HE) with 4.0mm diameters and 13mm lengths placed between the mental foramen. The groups were divided as follows: Group 1 - UCLA and metal bar; Group 2 - UCLA and occlusal acrylic resin coating; Group 3 - UCLA and porcelain coating; Group 4 - Abutment and metal bar; Group 5 - Abutment and acrylic resin coating; Group 6 - Abutment and porcelain coating. A force was applied, using a universal testing machine (EMIC), in different regions - in the most anterior implant, in the most posterior implant and in different cantilever extensions (up to 37.5 mm from the last implant) - in the metal bar and later in the metal bar with porcelain and acrylic resin coated prostheses. The results were obtained through photograph images and the Adobe Photoshop CS6 software was used for qualitative analysis. The analysis was performed according to the number of fringes with high intensity and to the stress distribution area. The results showed a greater number of high stress fringes as the cantilever extension increases. Groups with acrylic resin coating and with abutments exhibited greater stress distribution. We concluded that the use of abutments in acrylic resin protocol prostheses and the absence of the cantilever tends to decrease stress around implants / Mestre
163

Efeito da deficiência de magnésio sobre o metabolismo do tecido ósseo /

Belluci, Marina Montosa. January 2012 (has links)
Resumo: O magnésio (Mg+2) é um mineral que possui um importante papel na homeostase mineral, podendo afetar diretamente a função das células ósseas e a formação da hidroxiapatita. Entretanto, até o presente momento existem poucos estudos avaliando os mecanismos relacionados à alteração do metabolismo ósseo frente à deficiência de Mg. O objetivo desse estudo foi avaliar, in vitro, o efeito da deficiência de magnésio sobre a osteoclastogênese e atividade de osteoclastos. Também foi objetivo avaliar, in vivo, o efeito da deficiência de magnésio na dieta sobre o metabolismo ósseo, doença periodontal e tecido ósseo ao redor de implantes com osseointegração estabelecida. Para o estudo in vitro, foram avaliadas células indiferenciadas da medula óssea de ossos longos e mandíbula de camundongos. As células foram cultivadas em plástico e sobre tecido ósseo, em meios de cultura com diferentes concentrações de Mg (0.8 Mm que é considerada a quantidade adequada de Mg; e meios com redução do Mg, 0.4 Mm; 0.08 Mm; e 0 Mm). Após 3 dias de cultura, foram avaliadas a viabilidade celular, a taxa de proliferação celular e a expressão gênica, por PCR, de genes relacionadas à osteoclastogênese (c-fms, RANK, DC STAMP, c-fos, TNF-α e IL-1β) e ao metabolismo do Mg (TRPM-7 e MRS2). Após 6 dias de cultura, foram avaliados os parâmetros: número de células osteoclásticas (coloração de TRACP), atividade (liberação de TRACP) e taxa de proliferação celular. Após 8 dias de cultura a atividade dos osteoclastos foi avaliada por análise de pit de reabsorção. Para o estudo in vivo, foram utilizados 30 ratos, divididos em 2 grupos: grupo controle (CTL), que recebeu dieta com conteúdo adequado de magnésio, e grupo Mg, que recebeu dieta... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Magnesium (Mg) deficiency is very common condition in the world population. This mineral has an important role on bone homeostasis. However, there has been little research regarding the mechanisms in which magnesium deficiency alters bone metabolism. Also, the understanding of the factors associated to bone metabolism is of interesting for the prognosis of oral therapies, such as on periodontal disease and on osseointegrated dental implants. The aim of this study was to evaluate, in vitro, whether Mg deficiency affects the formation and/or activity of osteoclasts. And also to evaluate, in vivo, the effect of Mg intake deficiency on bone metabolism, periodontal disease and the bone tissue around osseointegrated implants. For the in vitro study, bone marrow cells from long bone and jaw of mice were seeded on plastic and on bone in medium containing different concentrations of Mg (0.8 mM which is 100% of the normal value, 0.4, 0.08 and 0 mM). The effect of Mg deficiency was evaluated on cell viability after 3 days and proliferation rate after 3 and 6 days, as was mRNA expression of osteoclastogenesis-related genes (M-CSF, RANK, c-fos, DC STAMP, TNF-α and IL-1β) and Mg-related genes (TRPM7 and MRS2). After 6 days of incubation, the number of tartrate resistant acid phosphatase-positive multinucleated cells (TRACP+-MNCs) was determined, and the TRACP activity of the medium was measured. Osteoclastic activity was assessed at 8 days by resorption pit analysis. For the in vivo studies, 30 rats received an implant in the right tibial metaphysis. After 60 days for healing of the implants, the animals were divided into groups according to the diet received. Control group (CTL) received a standard diet with adequate... (Complete abstract click electronic access below) / Orientador: Silvana Regina Perez Orrico / Coorientador: Carlos Rossa Junior / Banca: Denise Carleto Andia / Coorientador: Vicent Everts / Banca: Juliana Rico Pires / Banca: Paulo Sergio Cerri / Banca: Joni Augusto Cirelli / Doutor
164

Influência de uma superfície modificada por fluoretos na osseointegração de implantes dentais em ratos diabéticos /

Fontanari, Lucas Amaral. January 2013 (has links)
Orientador: José Eduardo Cezar Sampaio / Co-orientador: Elcio Marcantonio Junior / Banca: Humberto Osvaldo Schwartz Filho / Co-orientador: Silvana Regina Perez Orrico / Banca: Ana Emilia Faria Pontes / Banca: Joni Augusto Cirelli / Banca: Eduardo Hochuli Vieira / Resumo: Estudos pré-clínicos e clínicos têm demonstrado que algumas condições sistêmicas como o Diabetes mellitus podem alterar o processo de reparo ósseo. Na cavidade bucal, o diabetes pode estar associado à deficiência na osseointegração e pior prognóstico no tratamento com implantes dentais. Assim, modificações na superfície dos implantes que favoreçam a reparação do tecido ósseo poderiam ajudar a compensar as influências deletérias relacionadas ao diabetes. Este estudo tem por objetivo avaliar, em animais diabéticos, a influência de uma superfície modificada por fluoretos na osseointegração. A amostra consistiu de 180 ratos (90 para teste biomecânico e 90 para histometria) aleatoriamente divididos em três grupos de 60 animais: grupo controle (Grupo C), composto por ratos saudáveis; grupo Diabetes descompensado, composto por animais em que foi realizada indução de Diabetes mellitus (Grupo D); e grupo Diabetes Controlado (Grupo DC) em que o diabetes induzido experimentalmente foi controlado com administração de insulina. O diabetes foi induzido em ratos por injeção de estreptozotocina. Após 4 semanas da indução, cada animal recebeu 2 implantes nas metáfises tibiais proximais, sendo 1 de superfície maquinada (M) e o outro de superfície tratada com fluoretos (F). Os animais foram sacrificados 2, 4 e 6 semanas após a instalação dos implantes. A resistência biomecânica foi avaliada ex-vivo por meio do torque de remoção, e a qualidade do tecido ósseo formado ao redor dos implantes por meio de cortes histológicos não descalcificados, aonde mediu-se a superfície de contato osso/implante (BIC) e a fração de área de tecido ósseo entre as roscas do implante (BAFO). Os dados numéricos (peso, glicemia, torque de remoção, BIC e BAFO) foram avaliados estatisticamente por meio do teste de normalidade de Shapiro-Wilk e pelos testes paramétricos ANOVA complementado pelo... / Abstract: Pre-clinical and clinical studies have been showed that some systemic diseases like the diabetes mellitus may alter the bone repair process. At the oral cavity, the diabetes may be associated with poor osseointegration of dental implants and worsening of the prognosis of dental implants treatment. Thus, modifications on the dental implants surfaces that enhance the bone repair could help to offset the deleterious influences related to diabetes. The aim of this study was to evaluate, in diabetic rats, the influence of different implants surfaces on the osseointegration. A sample of 180 rats (90 for the biomechanical analysis and 90 for the histometric analysis) was randomly allocated in 3 groups of 60 rats each: Control Group (C): Healthy animals; Non-controlled diabetes Group (D): Animals with uncontrolled diabetes; Controlled Diabetes Group (DC): Animals with controlled diabetes. The diabetes was induced by injection of streptozotocin and it was controlled by injectios of insulin. After 4 weeks of the diabetes induction, all the animals received 1 implant in each tibia, one with a machined surface (M) and the other one with a fluoride surface modification. The animals were euthanized 2, 4 and 6 weeks after the implants placement. The biomechanical analysis was performed ex vivo by means of removal torque resistance, and the quality of the bone tissue formed around the implants was assessed by histometric analysis of bone / implant contact (BIC) and bone area between the threads of the implant (BAFO). The numerical data (Weight, Glicemic index, removal torque, BIC, and BAFO) were evaluated by the normality test of Shaprio-Wilk and the one-way Anova complemented by the Tukey's test. All the statistical test were applied with a significance level of 5%. Regarding the biomechanical analysis, for the machined surface implants, the group D showed lower removal torque values (p <0.05) than the group C... / Doutor
165

Efeito da altura do pilar de diferentes cimentos e das ciclagens térmica e mecânica sobre a resistência máxima á tração de infraestruturas metálicas cimentadas /

Alfenas, Bruna Fernandes Moreira. January 2013 (has links)
Orientador: José Mauricio dos Santos Nunes Reis / Banca: João Neudenir Arioli Filho / Banca: Marcelo Ferraz Mesquita / Resumo: Este estudo avaliou (1) o efeito da altura do pilar, dos diferentes cimentos e da termociclagem e (2) o efeito dos diferentes cimentos e da ciclagem mecânica sobre a resistência máxima à tração (RMT) de restaurações implantossuportadas cimentadas. Pilares de titânio (UCLA), com alturas de 4,0 e 6,0 mm (1), ou 4,0 mm (2), foram torqueados com 32 N.cm a análogos de implantes HI. Infraestruturas em Co-Cr, jateadas com óxido de alumínio 50 μm foram cimentadas com: Fosfato de Zinco- FZ; RelyX Luting 2- RXL2; C & B Cement- C&B; RelyX U100- RXU100 e RelyX Temp NE- RXTNE. Os conjuntos foram submetidos aos ensaios de tração (0,5 mm/min) após: 1- armazenagem em saliva artificial a 37 ºC durante 24 h (controle), 2- termociclagem (10.000 ciclos, 5,0 e 55 °C, 30 s de imersão), ou 3- ciclagem mecânica (106 ciclos, 140 N, 15 Hz). Os dados foram analisados por (1) 3- way ANOVA e Dunnett, e (2) 2-way ANOVA e Tukey HSD (α=0,05). Independentemente da altura do pilar, não houve diferença nos resultados dos grupos sem termociclagem (p≥0,05). Após termociclagem, houve aumento (p<0,05) na RMT nos pilares de 6,0 mm. Após ciclagem mecânica, houve diminuição (p<0,05) nos resultados de RMT produzidos por RXL2. A altura do pilar influenciou os resultados do RXL2, que produziu RMT mais elevada com os pilares de 6,0 mm. Com exceção do RXL2, a ciclagem mecânica não comprometeu a RMT das infraestruturas cimentadas. Em determinadas condições, o RXTNE produziu RMT semelhante à alguns cimentos finais. / Abstract: This study evaluate (1) the effect of abutment height, different cements and thermocycling, and (2) the effect of different cements and cyclic loading on the ultimate tensile strength (UTS) of cement-retained/implant-supported cast restorations. UCLA-type abutments with 4.0 and 6.0-mm height (1), or 4.0-mm height (2) were torqued to with 32 N.cm to internal hexagon dental implant replicas. Copings casted in Co-Cr, sandblasted with 50-μm aluminum oxide particles were cemented with: Zinc Phosphate- ZP; RelyX Luting 2- RXL2; C & B Cement- C&B; RelyX U100- RXU100 and RelyX Temp NE- RXTNE. The assemblies were submitted to the tensile test (0.5 mm/min) after: 1- storage in artificial saliva at 37 °C for 24 h (control), 2- thermocycling (10,000 cycles, 5.0 and 55 ºC, 30-s dwell time), or 3- cyclic loading (106 cycles, 140 N, 15 Hz). Data were analyzed by (1) 3-way ANOVA and Dunnett tests, and (2) 2-way ANOVA and Tukey HSD tests (α=0.05). Regardless of the abutments' heights, no significant differences were found among the UTS of the nonthermocycled groups (p≥0.05). After thermocycling, an increasing in the UTS was observed for the 6.0-mm abutments (p<0.05). After cyclic loading, the UTS values produced by RXL2 were decreased (p<0.05). The abutment's heights used affected the RXL2 results, which produced higher results with the 6.0-mm abutments. With the exception of RXL2, cyclic loading did not detrimentally affect the UTS of the cemented castings. In some conditions, the provisional cement RXTNE produced similar UTS to some definitive cements. / Mestre
166

Reciclagem de cavacos para a formação de carbonetos de titânio no metal de solda produzido por soldagem GTAW em aço-carbono /

Fagundes Júnior, José Gedael. January 2015 (has links)
Orientador: Juno Gallego / Co-orientador: Vicente Afonso Ventrella / Banca: Hidekasu Matsumoto / Banca: Warley Augusto Pereira / Resumo: O titânio é um metal nobre e possui excelentes propriedades biomecânicas, podendo assim ser plenamente aceito pelo organismo humano. A grande demanda na utilização de implantes dentários, fabricados a partir de ligas de titânio traz consigo um aumento significativo na geração de resíduos (cavacos), resultantes dos processos de usinagem empregados. Com o objetivo de reduzir os impactos ambientais, soluções alternativas para a reutilização de tais resíduos têm sido estudadas. O carboneto de titânio (TiC) possui elevada dureza, o que potencialmente permitiria a sua utilização como reforço em revestimentos antidesgaste aplicados em equipamentos das indústrias sucroalcooleira e mineradoras. Neste trabalho cavacos de ligas a base de titânio foram processadas e utilizadas como matéria prima para a fabricação de consumíveis experimentais. Revestimentos foram produzidos sobre amostras de aço-carbono por soldagem à arco elétrico com proteção gasosa e eletrodo de tungstênio, GTAW. A caracterização microestrutural do metal de solda foi realizada por microscopia eletrônica de varredura (MEV) e difração de raios-X (DRX). O comportamento mecânico dos revestimentos foi analisado por meio de um ultramicrodurômetro digital. Verificou-se que a microestrutura do metal de solda era composta por partículas não prismáticas de alta dureza distribuídas em uma matriz ferrítica. Análises químicas composicionais feitas por microanálise mostraram diferenças na concentração de titânio entre a matriz e as partículas, onde maiores teores deste elemento foram identificados. A análise cristalográfica confirmou que houve a formação de carbonetos de titânio e ferrita no metal de solda, comprovando a viabilidade no uso de cavacos de titânio para a fabricação de revestimentos duros / Abstract: The titanium element is a noble metal and it owns excellent biomechanical properties and can be accepted by human organism. The enormous necessity for utilization of dental implants fabricated with titanium alloys have caused an increased in generation of scraps or residues (chips) as a result of machining processes applied. Aiming to reduce the environmental impact, alternative solutions for reutilization of these residues have been studied. Titanium carbide (TiC) presents high hardness and potentially can be applied as hardfacing against wear in sugar-cane and mining equipment. In this work, chips of titanium from ASTM F67 (pure Ti) and ASTM F136 (Ti-6Al-4V) have been processed and used as a row material for fabrication of experimental hardfacing consumables. Weld metals were produced in low carbon steel specimens using GTAW processes (Gas Tungsten Arc Welding). The microstructures were investigated by scanning electron microscopy (SEM) and X-ray diffraction (XRD) techniques. The mechanical behavior of the weld metals was analyzed by a dynamic ultra-micro hardness tester. The microstructure of the welding metal was composed of non-prismatic and very hard particles surrounded by softer ferritic matrix. Measures made by electron dispersive spectroscopy (EDS) showed difference of the concentration of titanium trough the particle, where larger contents of titanium were found, and the matrix. The crystallographic analyses performed by XRD reinforced the formation of titanium carbides and ferrite in the welding metal and justifying the viability in using titanium chips as an alternative fabrication of hardfacing / Mestre
167

Estudo da distribuição das tensões geradas por implantes odontológicos com diferentes perfis de rosca

Chimendes, Luis Henrique [UNESP] 17 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-17Bitstream added on 2014-06-13T18:34:49Z : No. of bitstreams: 1 chimendes_lh_me_guara.pdf: 1177725 bytes, checksum: d07ba490bc7382650c018bc1d64cd30d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Muitas das características do implante estão relacionadas com sua longevidade, e uma dessas é o perfil de rosca empregado no projeto de sua criação. Assim, este estudo teve como objetivo analisar a distribuição da tensão gerada por implantes com diferentes perfis de rosca, através do método dos elementos finitos, num modelo bidimensional. Foram realizados oito modelos matemáticos de implantes mantendo-se as mesmas dimensões e modelo do conjunto implante e tecido ósseo, houve alteração somente no desenho do perfil de rosca empregado. Através do programa Ansys, simulou-se um carregamento axial de 100 N para todos os modelos, e os resultados das tensões obtidos foram analisados à luz do critério de Von Mises. Desse modo, observaram-se, modificando o desenho da rosca, variações de tensão no implante de até 30%, no osso compacto de até 40%, e no osso esponjoso de até 70%. Levando-se em conta o que foi observado, percebe-se a grande importância no planejamento do desenho das roscas do implante. Dentre os perfis de rosca analisados, dois modelos propostos na inovação obtiveram melhores resultados na distribuição de tensão no tecido ósseo. / Many features of the implant are related to their longevity, and one of them is the profile of screw employed in the project of creation. Thus the present study aimed to analyze the distribution of stress generated by implants with different profiles threaded, through the finite element method in a two-dimensional model. Were up eight models of implants and has been the same size and model of the whole implant and bone tissue, there was only change in the design of screw profile employee. Through the program ANSYS, is a simulated axial loading of 100 N for all models, and the results of the tensions were analyzed in light of the criterion of Von Mises. Thus, there were, modifying the design of screw, variations of tension in the implantation of up to 30% in the compact bone of up to 40% and the spongy bone of up to 70%. Taking into account what has been observed, it is very important in planning the design of the threads of the implant. Among the scenarios analyzed threads, two proposed models in innovation obtained better results in the distribution of stress in bone tissue.
168

Retorque de parafusos de pilares protéticos com recobrimento de carbono tipo diamante: uma análise da manutenção do torque após fadiga mecânica

Canavezi, Rafaela Cristiane [UNESP] 10 December 2015 (has links) (PDF)
Made available in DSpace on 2016-06-07T17:12:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-12-10. Added 1 bitstream(s) on 2016-06-07T17:17:17Z : No. of bitstreams: 1 000865436.pdf: 1601189 bytes, checksum: c34e3709b85d75f0d4c7ed707ac9c2a8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esta pesquisa se propôs verificar a manutenção do torque, após fadiga mecânica, de parafusos de pilares protéticos com recobrimento de carbono tipo diamante (DLC) e com dopagem de diamantes (CD-DLC) submetidos ao retorque, em conexões hexagonais externa (HE) e interna (HI). Implantes HE e HI e diferentes tratamentos do parafuso protético foram alocados em grupos experimentais (n = 5): sem tratamento e não submetidos a fadiga (HE-CON) (HI-CON); sem tratamento fadigados (HECONF) (HI-CONF); com DLC fadigado (HE-DLCF) (HI-DLCF) e com CDDLC fadigados (HE-CD-DLCF) (HI-CD-DLCF). Os recobrimentos de DLC e CD-DLC foram depositados a plasma pelo método PECVD. As amostras (implante + parafusos + coroa metálica), que já haviam sido expostas a 1 milhão de ciclos de fadiga, foram retorqueadas com torquímetro digital, com o torque recomendado pelo fabricante 30 N (HE) e 20 N (HI), e submetidos novamente a 1 milhão de ciclos mecânicos. Ao término da fadiga, os parafusos foram destorqueados para verificar a manutenção do torque. Parafusos de cada grupo experimental foram selecionados para observação em MEV. A análise estatística foi realizada pelo teste Anova 2- Fatores (α = 0,05). Não houve interação entre os fatores em estudo (p = 0,765); o tratamento dos parafusos (p = 0,638) e o tipo de conexão (p = 0,615) não apresentaram diferença estatística. Alterações como danos nas roscas do parafuso e remoção do filme foram observados entre os grupos experimentais. Os grupos com revestimento apresentaram pouco ou nenhum dano nas roscas dos parafusos. O revestimento de DLC e CDDLC parece não ter interferido na adaptação do parafuso ao implante. Parafusos protéticos recobertos com DLC e CD-DLC, após o retorque, não elevaram a manutenção do torque / The study analyzed the torque maintain of the screw abutments, with coating of diamond-like carbon (DLC) and doping of diamond (CD-DLC), submitted the retorque in external hexagonal (EH) and internal (IH) connections; after mechanical fatigue. HE and HI implants and different treatments of the abutments screws were divided into experimental groups (n = 5): untreated and not subjected to fatigue (EH-CON) (IHICON); fatigued untreatment (EH-CONF) (IH-CONF); fatigued with DLC (EH- DLCF) (IH-DLCF) and fatigued with CD-DLC (EH-CD-DLCF) (IH-CD-DLCF). The DLC and CD-DLC coating was deposited by plasma, PECVD method. Samples (Implant + abutment screew + metal crown), which had been exposed to 1 million fatigue cycles were retorquiadas, digital torque wrench, to the torque recommended by the manufacturer 30 N (HE) and 20 N (HI), and submitted again to 1 million cycles mechanics. At the end of fatigue, the screws were destorquiados to check the maintenance of torque. Screws from each experimental group were selected for observation by SEM. Statistical analysis was performed by ANOVA 2 Factors test (α = 0.05). There was no interaction among the factors studied (p = 0.765); the treatment of screws (p = 0.638) and the connection type (p = 0.615) showed no statistical difference. The microscopy images showed damage the threads and covering the presence of HI connections. Changes such as damage on the screws threads and film removal were observed among the experimental groups. The coating groups showed little or no damage on the screws threads. The DLC and CD-DLC coating did not interfere in the screw adaptation on the implant. Abutments screew coating with DLC and CD-DLC, after retorque, no raised torque maintenance
169

Efeito da administração de alendronato, a longo prazo, sobre as propriedades mecânicas do tecido ósseo, sua reparação e mineralização ao redor de implantes osseointegráveis. Estudo em ratas /

Verzola, Mario Henrique Arruda. January 2014 (has links)
Orientador: Silvana Regina Perez Orrico / Banca: Idelma Rangel Garcia Junior / Banca: Ana Paula de Souza Faloni / Banca: Morgana Rodrihues Guimarães / Banca: José Eduardo César Sampaio / Resumo: Este estudo teve como objetivo avaliar, em ratas, o efeito da terapia a longo prazo com bifosfonato sobre o processo de reparo e mineralização óssea ao redor de implantes e sobre as propriedades mecânicas do tecido ósseo. Para isso, 160 ratas foram distribuídas aleatoriamente em 2 grupos: grupo alendronato (ALD), no qual os animais receberam administração subcutânea de alendronato uma vez por semana, e grupo controle (CTL), no qual os animais receberam administração semanal de placebo, durante todo o período experimental. Após 120 dias do início do tratamento, um implante de titânio foi instalado na metáfise tibial, de ambos os lados. Dez animais de cada grupo foram sacrificados nos dias 5, 10, 15, 20, 25, 30, 45 e 60 pós-cirurgia, sendo retirados os fêmures e as tíbias. Os fêmures foram avaliados quanto à densitometria óssea e testes mecânicos. As tíbias contendo os implantes foram avaliadas quanto ao torque de remoção, análise histométrica (%BIC e %BAFO), microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva de raios-X (EDS), mapeamento da mineralização além de arranjo e distribuição do colágeno. Os resultados quanto à densitometria óssea demonstraram maiores valores para os animais do grupo ALD em relação ao grupo CTL, em todos os períodos de avaliação, com exceção do período de 15 dias. Os resultados dos testes mecânicos, de forma geral, demonstraram maior resistência à fratura (força máxima) e maior capacidade de absorção de energia (tenacidade) no grupo ALD em relação ao grupo CTL até o período de 45 dias. Para a rigidez, no período de 45 dias o grupo ALD apresentou valores significativamente maiores, entretanto sem diferença entre os grupos aos 60 dias. Em relação à resiliência, o grupo ALD demonstrou valores significativamente maiores somente no período de 45 dias. A droga influenciou no torque de remoção... (Resumo completo, acesse link abaixo) / Abstract: The aim of this study was evaluate in female rats, the effect of long-term therapy with bisphosphonate on the healing process and bone mineralization around implants and on the mechanical properties of bone tissue. One hundred sixty female rats were randomly allocated into two equally sized groups: the alendronate (ALD) group, which received the subcutaneous administration of alendronate (1 mg/kg/week), and the control (CTL) group which the animals received weekly the subcutaneous administration of saline solution (placebo) for the entire experimental period. After 120 days of the treatment initiation, in the booth groups, one titanium implant was installed in the tibia metaphysis. Ten animals in each group were euthanized at: 5, 10, 15, 20, 25, 30, 45, or 60 days after surgery, and their femurs and tibias were removed. The femurs were evaluated regarding bone mineral density (BMD), and mechanical tests. The tibias samples with the implants were evaluated by removal torque, histometric analysis (% BIC and % BAFO), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), mapping of mineralization and arrangement and distribution of the collagen. The results regarding bone densitometry showed higher values for the animals of ALD group compared with the CTL group at all evaluation periods, except for the period of 15 days. The results of mechanical tests, in general, showed higher fracture resistance (maximum force) and higher capacity of energy absorption (tenacity) in the ALD group compared with the CTL group until the 45 day. In the 45 days, the stiffness showed significantly higher values in the ALD group, however at 60 days no difference was observed between the groups. Regarding the resilience, the ALD group showed significantly higher values in the 45 days. The drug influenced the removal torque of implants with significantly higher values for ALD group until ...(Complete abstract electronic acess below) / Doutor
170

Influência da nicotina na osseointegração de implantes instalados em tíbias de ratos : avaliação biomecânica, histológica, histométrica e imunoistoquímica /

Faleiros, Paula Lazilha. January 2016 (has links)
Orientador: Alvaro Francisco Bosco / Coorientador: Juliano Milanezi de Almeida / Coorientador: Valdir Gouveia Garcia / Banca: Letícia Helena Theodoro / Banca: Edilson Ervolino / Banca: Marcio Zaffalon Casati / Banca: Leandro Araújo Fernandes / Resumo: Objetivo: Avaliar do ponto de vista biomecânico, histomorfométrico, histoquímico e através de marcadores imunoistoquímicos a influência da terapia com laser em baixa intensidade (LLLT) na osseointegração de implantes instalados em tíbias de ratos modificados ou não sistemicamente pela nicotina. Materiais e métodos: Um total de 120 ratos (Wistar) foi distribuído em dois grandes grupos experimentais (n = 60) submetidos a duas aplicações diárias de solução salina (Veh) ou nicotina (Nic). Após 30 dias, implantes de titânio (2.2 mm x 4 mm) foram instalados na metáfise proximal de ambas as tíbias de todos os animais. Grupos experimentais de diferentes tratamentos locais do alvéolo cirúrgico previamente a instalação do implante (n = 30) foram criados no momento da cirurgia: Veh - nenhum tratamento; Veh/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade; Nic - nenhum tratamento; Nic/LLLT - irradiação do alvéolo cirúrgico com laser em baixa intensidade. O laser utilizado foi o Thera Lase (InGaAlP 660 nm, modo de aplicação contínuo, em contato com a área, 35 mW, 0,14 J, 4,9 J/cm2, por 4 segundos). Dez animais de cada grupo foram eutanasiados aos 15, 30 e 60 dias pós-operatórios. As tíbias direitas foram submetidas à análise de torque reverso e posteriormente processadas para confecção de cortes histológicos descalcificados, corados por hematoxilina e eosina, vermelho picrosirius ou submetidos a reações imunoistoquímicas com os anticorpos primários policlonais: HIF-1 ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: To evaluate, from biomechanical, histomorphometric, histochemical stand point and through of immunohistochemical markers, the influence of low level laser therapy (LLLT) on the osseointegration of implants placed in the tibias of nicotine systemically modified (or not) rats. Materials and methods: A total of 120 rats (Wistar) was assigned into two major experimental groups (n = 60) underwent two-daily-applications of saline (Veh) or nicotine (Nic). After thirty days, titanium implants (2.2 mm x 4 mm) were placed in the proximal metaphysis of both tibiae from all animals. Experimental groups of different surgical alveolus local treatments prior to implant placement (n = 30) were created at the moment of the surgery: Veh - no local treatment; Veh/LLLT - irradiation of surgical alveoli with low level laser; Nic - no local treatment; Nic/LLLT - irradiation of surgical alveoli with low level laser. The laser used was Thera Lase® (InGaAIP 660 nm, in continuous mode, in contact with the area, 35 mW, 0.14 J, 4.9 J/cm2, for 4 seconds). Ten animals from each group were euthanized at 15, 30 and 60 days postoperative. The right tibiae were submitted to reverse-torque analysis and, then processing in order to prepare decalcified histological sections, stained either by hematoxylin and eosin or picrosirius red or subjected to immunohistochemical reactions with the primary polyclonal antibodies: HIF-1 α, VEGF, BMP-2, RUNX-2, OCN, ALP, RANKL, OPG and TRAP. From left tibias were p... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0855 seconds