• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 851
  • 34
  • 32
  • 32
  • 31
  • 23
  • 9
  • 9
  • 9
  • 7
  • 5
  • 5
  • 3
  • 2
  • Tagged with
  • 881
  • 881
  • 560
  • 490
  • 219
  • 205
  • 156
  • 118
  • 104
  • 98
  • 87
  • 85
  • 83
  • 81
  • 76
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
391

Rehabilitation of fully edentulous maxilla = retrospective survival analysis of dental implants in native x autogenous bone and proposed technique for bone reconstruction with rhBMP-2 = Reabilitações de maxilas totalmente edêntulas: análise retrospectiva de sobrevida de implantes dentários em osso nativo x enxerto autógeno e proposta de técnica para reconstrução óssea com rhBMP-2 / Reabilitações de maxilas totalmente edêntulas : análise retrospectiva de sobrevida de implantes dentários em osso nativo x enxerto autógeno e proposta de técnica para reconstrução óssea com rhBMP-2

Moraes, Paulo Hemerson de, 1982- 24 August 2018 (has links)
Orientador: José Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T03:15:23Z (GMT). No. of bitstreams: 1 Moraes_PauloHemersonde_D.pdf: 8285563 bytes, checksum: e294a6dc0647058066633e61386f29b1 (MD5) Previous issue date: 2013 / Resumo: Em maxilas severamente absorvidas, como tratamento de reabilitação, podem ser utilizados os implantes dentais osseointegráveis convencionais. Todavia, nestas situações, estão presentes obstáculos para a instalação dos implantes como: quantidade insuficiente e qualidade inadequada do osso encontrado na maxila. Nestas situações, são necessárias cirurgias reconstrutivas para restabelecer as dimensões do rebordo avelolar em espessura e altura possibilitando assim a instalação adequada destes implantes. Geralmente, essas reconstruções utilizam osso autógeno retirado de algum sitio doador do paciente, como a calota craniana, costela e crista do ilíaco. Alternativamente, com os avanços da engenharia tecidual, a rhBMP-2 (recombinant human bone morphogenethic protein-2) surgiu eliminando a necessidade de qualquer remoção de sítio doador como também qualquer outro biomaterial nas reconstruções ósseas dos maxilares deixando o procedimento com menor morbidade e maior aceitabilidade dos pacientes. Desta forma, a presente pesquisa apresenta 2 estudos descritos nos capítulos a seguir. CAPÍTULO 1: O objetivo deste estudo foi avaliar a sobrevida de implantes instalados em osso nativo de maxilas como também nas reconstruídas com osso autógeno. Foi obtido um acompanhamento de 8-10 anos com pacientes de ambos os grupos reabilitados com próteses fixas sobre implantes dentais. O sucesso dos implantes em maxilas reconstruídas com ósso autogeno não apresentaram diferenças estatísticas à implantes inseridos em maxilas com osso nativo. CAPÍTULO 2: O objetivo deste estudo foi apresentar uma nova técnica de reconstrução óssea de maxila utilizando rhBMP-2 objetivando previsibilidade e melhores resultados no aumento do volume ósseo necessário. A técnica sugerida ofereceu bons resultados no volume ósseo a ser obtido nas reconstruções ósseas de maxila com rhBMP-2. / Abstract: In maxillary severely absorbed as rehabilitation treatment, can be used conventional dental implants. However, these situations are present obstacles to the installation of the implants as insufficient and inadequate quality of bone found in the jaw , as well as the expansion of the maxillary sinus pneumatization . In these situations, it is necessary reconstructive surgery to restore the dimensions of thickness and height on rim thus allowing proper installation of these implants. Generally, these reconstructions using autogenous bone taken from a donor site from the patient , such as calota craneal , rib and the iliac crest . Alternatively, with advances in tissue engineering, rhBMP-2 (recombinant human bone morphogenethic protein-2) appeared eliminating the need to remove any donor site as well as any other biomaterial in the maxila bone reconstruction procedure with leaving the lower morbidity and higher patient acceptability. Given the above, this research presents two studies described in the following chapters. CHAPTER 1: The objective of this study was to evaluate the survival of implants placed in native bone in the maxilla as well as in maxilla reconstructed with autogenous bone. We obtained a follow-up of 8-10 years with both groups of patients rehabilitated with fixed prostheses on dental implants. The survival of implants in maxilla was reconstructed with autogenous bone implants inserted into the lower maxilla with native bone. CHAPTER II: The objective of this study was to present a new technique for reconstruction of maxilla bone using rhBMP-2 seeking precision in increased bone volume needed. The suggested technique offered precision in bone volume to be obtained in the maxilla bone reconstruction with rhBMP-2. / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
392

Análise extensométrica e do desajuste marginal de infra-estruturas implanto-retidas nas configurações linear e compensada com diferentes coifas sob aplicação de cargas axiais e não axiais / Analysis of marginal misfit and strain gauge in implant-supported frameworks using straight line and offset placement with different copings under axial and non-axial load

Abreu, Celina Wanderley de, 1982- 19 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T03:08:59Z (GMT). No. of bitstreams: 1 Abreu_CelinaWanderleyde_D.pdf: 708429 bytes, checksum: e7e9243a443a7387eced5b96c49b0b3c (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo in vitro, foi analisar microscopicamente o desajuste vertical e passivo e quantificar a deformação usando análise de extensometria durante aplicação de carga axial e não-axial em prótese parcial fixa implanto-suportada de três elementos, variando a posição dos implantes, linear (L) ou compensada (C) e o tipo de coifa protética, plástica (P) ou colar metálico (M). Três implantes cone morse posicionados linear e três numa configuração compensada foram inseridos em dois blocos de poliuretano. Pilares microunit foram parafusados nos implantes aplicando torque de 20 Ncm. Coifas plásticas e com colar metálico foram parafusados nos pilares que receberam enceramentos padronizados. Os padrões de cera foram fundidos em liga Co-Cr (n=5) e separados em quatro grupos: G1- L/P; G2- L/M; G3- C/P e G4- C/M. Quatro strain gauges (SG) foram colados na superfície de cada bloco tangencialmente aos implantes. Os parafusos de retenção das supra-estruturas foram parafusados nos pilares com torque de 10 Ncm e, em seguida, foram aplicadas as cargas. A magnitude da microdeformação em cada strain gauge foi registrada em unidade de microdeformação (??). Os níveis de desajuste vertical foram mensurados com todos os parafusos apertados com torque de 10 Ncm e o desajuste passivo com apenas um parafuso apertado. A análise do desajuste foi feita utilizando microscópio óptico com precisão de 0,5 ?m e 120x de aumento. Os dados foram analisados estatisticamente pela ANOVA e teste de Tukey (p<0.05). Não foi observada diferença estatisticamente significativa para desajuste passivo (p>0.05), porém houve diferença no desajuste vertical para o fator configuração (p=0.0257). Na quantidade de deformação por meio da extensometria foi encontrada diferença no fator configuração (p=0.0005). Após o teste Tukey foi observada uma diferença entre L/P (306.1±82.25) e C/P (146.6±93.64). Não houve diferença significante entre carga axial e não axial. Existiu evidência de que a posição offset é capaz de reduzir a deformação em torno do implante. Em adição, o tipo de carga, axial ou não-axial até 2mm não teve influência e o tipo de coifa usado também não interferiu / Abstract: The aim of this in vitro study was microscopically analyzing the vertical and passive misfit and quantify the strain development using strain gauge analysis during axial and non-axial loading in three-element implant-supported FPDs, varying the arrangement of the implants: straight line (L) and offset (O) and the type of prosthetic coping used: plastic (P) or metallic collar (M). Three Morse taper implants arranged in a straight line and three implants arranged in an offset manner were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, using a torque of 20Ncm. Plastic and metallic collar copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in Co-Cr alloy (n=5), making a total of four groups: G1- L/P; G2- L/M; G3- O/P and G4- O/M. Four strain gauges (SG) were bonded on the surface of each block tangential to the implants. The superstructure's occlusal screws were tightened onto the microunit abutments using 10 Ncm torque with a manual torque driver and then an axial load was applied. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (??). An optical microscope, with 0.5 ?m of measurement accuracy and 120x magnification, was used to evaluate the vertical fit with all of the screws tightened to 10 Ncm torque and the passive fit with only one screw tightened to the appropriate torque. The data were analyzed statistically by ANOVA and Tukey's test (p<0.05). There was not statistically significant difference for passive misfit (p>0.05), but a significant difference existed in vertical misfit for the factor of configuration (p=0.0257). A significant difference was also observed for strain for the factor of configuration (p=0.0005). The Tukey's test revealed difference between L/P (306.1±82.25) and O/P (146.6±93.64). There was not statistically significant difference between axial and non-axial load. There was evidence that the offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or non-axial did until 2 mm not have an influence and the type of coping used did not interfere / Doutorado / Protese Dental / Doutor em Clínica Odontológica
393

Estudo in vitro da biomecânica de prótese fixa implantossuportada por meio da extensometria linear elétrica / In vitro biomechanical study of implant prosthesis fixed by means of linear electrical extensometry

Ribeiro, Lívia Forster, 1978- 20 August 2018 (has links)
Orientador: Wilkens Aurélio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T01:35:28Z (GMT). No. of bitstreams: 1 Ribeiro_LiviaForster_M.pdf: 2135600 bytes, checksum: 328020004d2dfccf85672ad44205aa07 (MD5) Previous issue date: 2012 / Resumo: Este estudo in vitro teve como objetivo, avaliar as deformações de implantes e componentes protéticos de uma prótese parcial fixa implantossuportada, submetida às cargas axiais por meio da extensometria elétrica. Foi confeccionado um modelo experimental, simulando um hemi-arco desdentado, referente aos elementos 15 ao 18, reabilitados com análogos de implantes osseointegrados, na posição dos elementos 15 e 17, e um corpo de prova simulando uma prótese parcial fixa metálica constituída de liga de Níquel-Cromo (Ni-Cr), com os pônticos localizados nos elementos 16 e 18, sendo este último com extensão em cantilever. Na região cervical dos análogos e cervicais dos pilares, foram fixados quatro extensômetros um em cada face, mesial, distal, vestibular e palatina. No corpo de prova foram fixados quatro extensômetros na cervical da prótese. O corpo de prova foi submetido a um teste de cargas axiais controladas, utilizando o sistema de aquisição de dados AqDados e AqDAnalysis (ADS0500IP- Lynx). Os ensaios mecânicos, com cargas estáticas compressivas axiais de 150N, foram realizados em máquina universal de ensaio DL EMIC 2000 0,5mm/min. Os resultados obtidos neste estudo mostraram que todos os componentes avaliados apresentaram valores consistentes de deformação por compressão e/ou tração, em função do carregamento aplicado (p<0,0001). Desta forma, foi possível concluir que as deformações observadas entre a região cervical do corpo de prova, pilares protéticos e análogos de implantes foram significativamente diferentes entre si (p<0,005 ou p<0,001), e que os fenômenos mecânicos observados foram de natureza deflectiva com características de compressão e tração. As comparações realizadas no plano horizontal mostraram diferenças estatisticamente significantes, na região dos análogos dos implantes, e as comparações realizadas no plano vertical exibiram diferenças significativas entre os componentes do sistema de um dos análogos estudados / Abstract: This study in vitro aimed to evaluate the deformation of implants and prosthetic components of implant-fixed partial denture, subjected to axial loads by means of strain gages. We made an experimental model simulating a hemi-arch edentulous, referring to the elements 15 to 18, similar rehabilitated with osseointegrated implants in the position of the elements 15 and 17, and a sample simulating a fixed partial denture metal alloy consisting of Nickel-Chromium (Ni-Cr), with elements located in pontics 16 and 18, the latter extending in cantilever. In the cervical region of the pillar analogs and neck, four strain gauges were attached one on each side, mesial, distal, buccal and palatal. In the sample have been set in four strain gages neck of the prosthesis, two strain gages under the pontic element and under the region on the cantilever. The sample has been subjected to an axial load controlled test, using the data acquisition system and AqDados AqDAnalysis (ADS0500IP-Lynx). The mechanical tests with static compressive axial 150N, were performed on universal testing machine EMIC DL 2000 0.5 mm / min. The results of this study showed that all components evaluated had consistent values of compression set and / or traction as a function of applied load (P <0.0001). Thus, was possible to conclude that the observed deformations of the cervical region of the body of evidence, pillars and similar prosthetic implants were significantly different (P <0.005 or 0.001), and the mechanical phenomena observed in nature were deflected with characteristics of compression and tension. The comparisons made in the horizontal plane showed statistically significant differences in the analogous region of the implants, and the comparisons made in the vertical plane showed significant differences between the system components of a similar study / Mestrado / Protese Dental / Mestre em Clínica Odontológica
394

Mensurações verticais para planejamento de mini-implantes palatinos em telerradiografia em norma lateral e tomografia computadorizada de feixe cônico / Vertical measurements for planning palatal mini-implants in lateral radiograph and cone beam computed tomography

Barbosa, Gabriella Lopes de Rezende, 1988- 20 August 2018 (has links)
Orientador: Solange Maria de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T06:56:36Z (GMT). No. of bitstreams: 1 Barbosa_GabriellaLopesdeRezende_M.pdf: 1476954 bytes, checksum: 655317fdf41b3d0e2548c438c0fe7358 (MD5) Previous issue date: 2012 / Resumo: Os objetivos deste estudo foram comparar as mensurações lineares referentes à altura óssea palatina na região de primeiros pré-molares superiores para inserção de miniimplantes palatinos por meio de imagens de telerradiografia em norma lateral (TNL), tomografia computadorizada de feixe cônico (TCFC) e telerradiografia reconstruída do exame tomográfico (telerradiografia virtual); assim como comparar as alturas ósseas das regiões medianas e paramedianas do sítio avaliado. Para tanto, foram utilizadas 110 imagens de TNL, telerradiografia virtual e TCFC, dos mesmos pacientes. Para avaliação das alturas nas imagens, foi realizada mensuração da distância entre a intersecção do longo eixo do primeiro pré-molar com o assoalho do palato duro e o assoalho nasal, a qual correspondeu à dimensão do osso disponível para inserção de mini-implantes de ancoragem. Para avaliação das alturas medianas e paramedianas no corte tomográfico na região de primeiro pré-molar, foram realizadas mensurações da distância entre a camada cortical do assoalho nasal e a cortical do palato duro nos sítios central, 3 mm à direita e à esquerda, 6 mm à direita e à esquerda. As mensurações foram realizadas por três avaliadores. Os valores encontrados da TNL não diferiram estatisticamente (p>0,05) da TCFC (padrão-ouro), sendo comparáveis aos do exame tomográfico. Já os valores da telerradiografia virtual diferiram estatisticamente (p<0,05) tanto da TCFC quanto da TNL, sendo medidas subestimadas quando comparadas ao padrão-ouro e à técnica radiográfica. Quando comparadas as medidas dos sítios avaliados, não houve diferença estatística (p>0,05) entre as alturas paramedianas e a central. Concluiu-se que as mensurações realizadas para planejamento de inserções de mini-implantes palatinos na região dos primeiros prémolares são comparáveis nos exames de TNL e em reconstruções multiplanares de TCFC, e subestimadas nos exames de telerradiografia virtual. Concluiu-se também que as regiões paramedianas bilaterais a 3mm e 6mm da sutura palatina na região avaliada possuem altura óssea comparável à região mediana do palato / Abstract: The aims of this study were to compare linear measurements related to the palatal bone thickness in the region of first premolars to insert palatal mini-implants on images of conventional lateral radiography (CLR), cone beam computed tomography (CBCT) and reconstructed radiography from CBCT scan (virtual radiograph), as well as compare the thickness of the bone regions of the median and paramedian site assessed. For this purpose, 110 images of CLR, virtual radiography and CBCT of the same patient were used. To evaluate the thicknesses on the images, measurements was performed between the distance of the intersection of the long axis of the first premolar to the hard palate floor and nasal floor, which corresponded to the relevant dimension of available bone for insertion of mini-implants. To evaluate the thickness in median and paramedian regions on CT slice in the region of first premolar, measurements were made between the cortical layer of the nasal floor and hard palate, on central site and paramedian sites 3 mm and 6 mm bilaterally. The measurements were performed by three evaluators. The values found on TNL were not statistically different (p> 0.05) of CBCT (gold standard).The values of the virtual radiography were statistically different (p <0.05) from CBCT and TNL, being underestimated when compared to the gold standard and the radiographic technique. When comparing the measurements of the sites studied, there was no statistical difference (p> 0.05) between the thicknesses of the central site and paramedian sites. It was concluded that the measurements made for planning palatal mini-implants, at the level of the first premolars, is comparable on TNL and multiplanar reconstructions of CBCT, while underestimated in virtual radiography examinations. It is also concluded that the bilateral paramedian regions at 3mm and 6mm from the palatal suture, in the region evaluated, have bone thickness comparable to the median region of the palate / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
395

Influência da prótese parcial removível implanto-retida sobre a mastigação e ingestão de nutrientes / Influence of implant retained removable partial denture on mastication and nutrient intake

Campos, Camila Heitor, 1985- 21 August 2018 (has links)
Orientador: Renata Cunha Matheus Rodrigues Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T19:03:37Z (GMT). No. of bitstreams: 1 Campos_CamilaHeitor_M.pdf: 2422429 bytes, checksum: 76c19be5f9518ea87df73f84487061c9 (MD5) Previous issue date: 2012 / Resumo: A reabilitação de arcos parcialmente dentados por meio de próteses parciais removíveis (PPR), sobretudo aqueles com ausência de dentes posteriores, apresentam limitações relativas ao suporte da prótese, que nestes casos é dividido entre dentes e mucosa, estruturas com diferentes resiliências. A associação de implantes osseointegrados à base da PPR tem como proposta atenuar estas limitações e trazer benefícios para o paciente, porém, a literatura sobre este assunto é escassa. Desta forma, este estudo se propôs a avaliar o efeito da associação de implantes osseointegrados pela adição de encaixe posterior implanto-retido à base de PPR mandibulares sobre o limiar de deglutição e ingestão de nutrientes. Oito voluntários (idade média = 60,1 ± 6,6 anos) apresentando edentulismo total maxilar e parcial mandibular (Classe I de Kennedy) foram selecionados e reabilitados com próteses totais (PT) maxilares e PPR mandibulares. Após dois meses de uso das novas próteses, as variáveis acima citadas foram mensuradas. Em uma segunda etapa, os mesmos voluntários receberam dois implantes osseointegrados bilaterais na região de molares inferiores. Após o período de osseointegração, foram adicionados encaixes do tipo bola aos implantes e à base da PPR, e após dois meses de uso das PPR implanto-retidas as variáveis foram novamente mensuradas. O limiar de deglutição foi avaliado por meio da contagem do número de ciclos mastigatórios realizados para a mastigação de uma porção de amendoim até o paciente sentir que está na iminência de deglutir. Foi ainda realizado o cálculo do tamanho mediano de partículas trituradas (X50), utilizando o material teste mastigável Optocal, pelo método de fracionamento de peneiras. O estado nutricional foi avaliado por meio de diário alimentar de três dias, e posteriormente foi traduzido em valores nutricionais por meio da utilização da Tabela Brasileira de Composição de Alimentos. Foram realizadas análises comparativas pareadas, sendo utilizados os testes T de Student e Wilcoxon para nível de significância de 5%. Embora não tenha ocorrido mudança no número de ciclos mastigatórios necessários à deglutição após a inserção do encaixe implanto-retido (P>0,05), houve redução significativa do X50 (P<0,05). Observou-se, ainda, aumento na ingestão de calorias (P=0,008) e no consumo diário de carboidratos (P=0,003), proteína (P=0,023), cálcio (P=0,006), fibras (P=0,040) e ferro (P=0,038). Não foram detectadas alterações na ingestão de gordura e no IMC (P>0,05). Pode-se concluir que a associação de implantes às PPR por meio encaixe do tipo bola apresenta efeito positivo sobre a mastigação e ingestão de nutrientes em pacientes com arcos Classe I de Kennedy / Abstract: The rehabilitation of partially dentate arches with removable partial dentures (RPD), especially those with absence of posterior teeth, have limitations regarding RPD support, divided between teeth and mucosa, with different structures resilience. The association of dental implants beneath RPD base proposal is to reduce these limitations and bring benefits to patients; however, the literature on this is scarce. Therefore, this study aimed to assess the impact of the use of a posterior implant retainer for free-end RPD on the swallowing threshold and nutrient intake. For this purpose, eight volunteers (mean age = 60.1 ± 6.6 years) presenting maxillary edentulism and mandibular partially dentate arch (Kennedy Class I) were selected and rehabilitated with maxillary complete dentures (PT) and mandibular RPD. After two months of use of the new prosthesis, the variables were measured. In a second step, the same volunteers received two osseointegrated implants, bilaterally in the region of mandibular first molars. After healing time, ball attachments were added to the implants and fitted on the RPD base, providing retention, and after two months of using, the variables were again measured. The swallowing threshold was assessed by counting the number of masticatory cycles and by calculating the median particle size reduction (X50). The number of masticatory cycles performed for chewing a portion of peanuts until the patient felt need to swallow was registered by the researcher. The X50 value was determined by sieve fractioning method using the chewable test material Optocal. Nutritional state was assessed by three-day food diary and further compared to the Brazilian Food Composition Table. Comparative analyzes were made by using the Paired Student's t-test and Wilcoxon Rank-test, depending on the normality distribution of data, and for 5% of significance level. Although there was no change in the number of chewing cycles needed to swallow after implant insertion (P>0.05), there was a significant reduction in the average size of the particle to be swallowed (P<0.05). There was also an increase in energy intake (P=0.008) and daily consumption of carbohydrates (P=0.003), protein (P=0.023), calcium (P=0.006), fiber (P=0.040) and iron (P=0.038). No changes were detected in fat intake and BMI (P>0.05). It can be concluded that the association of implants to RPD by ball attachment insertion may have positive effect on chewing and nutrient intake in patients with Class I Kennedy arches / Mestrado / Protese Dental / Mestra em Clínica Odontológica
396

Comparação entre substitutos osseos de origem bovina sobre o processo de regeneração ossea guiada em defeitos perimplantares : analise histologica e histometrica em tibia de cães

Asprino, Luciana, 1974- 14 April 2003 (has links)
Orientador: Jose Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T08:29:38Z (GMT). No. of bitstreams: 1 Asprino_Luciana_M.pdf: 3041173 bytes, checksum: a32815e20344c2ce2ae3fe3771a3e21c (MD5) Previous issue date: 2003 / Resumo: O objetivo deste trabalho foi avaliar, através de análise histológica e histométrica a interferência da matriz óssea bovina desmineralizada e da proteína óssea morfogenética no processo de regeneração óssea guiada em defeitos perimplantares. Para isso foram instalados três implantes em cada tíbia de quatro cães, sendo que dois cães foram sacrificados no 21°, e dois no 42° dias pós-operatório. Foi confeccionado um defeito perimplantar a cada implante, que foram preenchidos e recobertos com membrana de colágeno. No grupo controle o defeito foi preenchido com osso autógeno particulado, no grupo MOS com matriz óssea bovina e no grupo SMP com um "pool" de SMPs adsorvido à hidroxiapatita. A análise histológica mostrou neoformação óssea preenchendo totalmente os defeitos perimplantares no período pós-operatório de 21 dias, com maior maturação óssea no período pós-operatório de 42 dias, nos três grupos estudados. Os dados histométricos revelaram que a média de neoformação óssea no período de 42 dias foi significativamente superior a média de neoformação óssea no período de 21 dias. Entre os grupos houve maior neoformação óssea para o Grupo BMP, nos dois períodos. Porém só houve diferença estatística significante em relação ao Grupo MOS no período pós operatório de 21 dias. Diante da metodologia empregada, a SMP induziu maior neoformação óssea do que os outros grupos e que a BMP e MOS empregadas comprovaram sua efetividade como substitutos ósseos / Abstract: The aim of this study was evaluate histologically and histometrically the effect of a bovine demineralized bone matrix and bone morphogenetic protein on guided bone regeneration process in bone fenestration defects associated with dental implants. Therefore, three titanium implants were placed in each tibia of four dogs and the defects were filled with autogenous bone, bovine demineralized bone matrix (BBM) and a "pool" of bone morphogenetic protein bound to hidroxyapatite. Ali defects were protected with collagen membranes. After the periods of three and six weeks the animais were sacrified. The histological results showed bone neoformation filling totally the defects at three weeks, and greatest bone maturation at six weeks in ali groups. The histometric results revealed better scores of bone deposition at six weeks with estatistical difference at three weeks, in ali samples. Among the groups, BMP group was the one that showed the best results, in both periods. However, there was only estatistical difference to the MOB group at the period of three weeks. Within the limits of the present study, the BMP provided better scores of bone deposition, and that the BMP and BBM can be used like bone substitutes / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
397

Analise da adaptação de estruturas de proteses sobre implantes pre-fabricadas ou fundidas em titanio, antes e apos soldagem a laser

Alves, Bruno Pereira 03 August 2018 (has links)
Orientador : Mauro Antonio de Arruda Nobilo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T10:06:47Z (GMT). No. of bitstreams: 1 Alves_BrunoPereira_D.pdf: 1001479 bytes, checksum: c0e104047b0ff3ab21357a7d0f93f791 (MD5) Previous issue date: 2003 / Doutorado
398

Analise in vitro da infiltração bacteriana e das desadaptações na interface implante/conector protetico em cinco sistemas de implantes endoosseos

Amaral, Jose Ivo Queiroz do 03 August 2018 (has links)
Orientador: Renato Mazzonetto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T19:00:30Z (GMT). No. of bitstreams: 1 Amaral_JoseIvoQueirozdo_D.pdf: 1822272 bytes, checksum: f6376ccbe26730cf7498f99e4595888d (MD5) Previous issue date: 2003 / Doutorado
399

Caracterização de revestimentos de hidroxiapatia depositados por aspersão termica a plasma sobre a liga Ti-13Nb-13Zr para aplicação em implantes dentarios

Lima, Petronio Medeiros 22 November 2004 (has links)
Orientador : Cecilia Amelia de Carvalho Zavaglia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T02:52:27Z (GMT). No. of bitstreams: 1 Lima_PetronioMedeiros_D.pdf: 6348939 bytes, checksum: 54056cc426bd5ba4ea2e3b938bed037d (MD5) Previous issue date: 2004 / Resumo: A liga Ti-13Nb-13Zr tem sido proposta como um novo biomaterial metálico por apresentar em sua fonnulação alguns dos elementos metálicos de maior biocompatibilidade (Ti, Nb, Zr e Ta), além de apresentar excelente resistência à corrosão e baixo módulo de elasticidade (E). A liga Ti-13Nb-13Zr, foi obtida por metalurgia do pó. Substratos desta liga foram a seguir revestidos com hidroxiapatita (HA) por aspersão ténnica a plasma visando viabilizar a sua utilização como implantes dentários. Foram utilizadas técnicas de caracterização desses substratos revestidos para avaliação dos efeitos da HA sobre a cristalinidade e propriedades fisicas, mecânicas, eletroquímicas e biológicas dos revestimentos. Foram obtidos revestimentos de boa qualidade com baixa porosidade, baixo nível de partículas não fundidas, sem trincas e com boa adesão. O ensaio de resistência ao risco mostrou-se ser um ensaio reprodutível. A liga Ti13Nb-13Zr revestida com HA é ligeiramente mais resistente à corrosão que a liga não revestida. A liga revestida com HA e não revestida não apresentaram efeitos citotóxico frente à cultura de células osteoblástcas testada. A liga revestida com HA apresentou melhor adesão em cultura de células osteoblásticas a longo tempo de estudo in vitro em comparação com a liga Ti-13Nb-13Zr não revestida / Abstract: The Ti-13Nb-13Zr alloy has been proposed as a new metallic biomaterials wich stands out for introducing in its fonnulation three of the four metallic elements of larger biocompatibility (Ti, Nb, Zr, Ta), besides introducing, low elasticity modulus and excellent corrosion resistance. The Ti-13Nb-13Zr alloy was obtained from powder metallurgy. Substrates of this alloy were coated with hydroxyapatite (HA) deposited by thermal plasma aspersion aiming to make possible its utilization in dental implants. There were used techniques of characterization for these coated substrates to evaluate effects of hydroxyapatite on the crystalinity and physical, mechanical, electrochemical and biological properties of the coatings. There were obtained good quality coatings with low porosity, low leveI of not fused particles, without crack and with good adhesion. The resistance scratch test showed to be a reproducible test. The alloy coated HA is lightly more resistant to the corrosion that the uncoated alloy. The alloy coated HA and uncoated did not show any type of cytotoxicity for culture osteoblastic cells. The HA coated a lloy did present better adhesion results for culture osteoblastic cells the long time of study in vitro in comparison to the Ti-13Nb-13Zr alloy uncoated one / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
400

Precisão de medidas lineares em imagens tomograficas

Guedes, Fabio Ribeiro 24 February 2005 (has links)
Orientador: Glaucia Maria Bovi Ambrosano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:10:26Z (GMT). No. of bitstreams: 1 Guedes_FabioRibeiro_M.pdf: 16708948 bytes, checksum: 136372754eec5ecaf8e3293298f9b330 (MD5) Previous issue date: 2005 / Resumo: Foi identificado o fator de magnificação de tomógrafos convencionais e comparado a mangnificação fornecida pelos fabricantes, e a confiabilidade de medidas lineares das imagens tomográficas corrigidas, quando comparadas às mensurações reais nos segmentos ósseos. Foram utilizadas 16 mandíbulas humanas maceradas edêntulas, e selecionada região correspondente aos incisivos, caninos, pré-molares e molares bilateralmente. Em cada região foram fixados sobre a crista óssea e na região vestibular, um fio ortodôntico com 5,0 milímetros de comprimento, que foi utilizado como guia radiográfico. Os equipamentos utilizados neste trabalho foram os tomógrafos convencionais Quint Sectograph, Orthopantomograph OP100, X Mind TOME, e computadorizados Somatom Esprit com reconstrução multiplanar e Toshiba X vision EX com software Denta Scan. As mandíbulas foram posicionadas nos tomógrafos convencionas conforme as especificações dos fabricantes e obtidas as imagens. Para os tomógrafos computadorizados as mandíbulas foram posicionadas com suas bases perpendiculares ao solo e obtidas as imagens axiais ara posterior reconstrução oblíquo-sagital das regiões. Após obtidas as imagens, foram mensuradas a altura e espessura óssea de cada região, corrigindo-se as medidas com base a ampliação do guia radiográfico e em seguida com o fator de magnificação dado pelo fabricante. As mandíbulas foram seccionadas exatamente nas regiões selecionadas, e realizadas as medidas da altura e espessura óssea, obtendo-se os valores reais por região. As magnificações calculadas, por meio do guia radiográfico dos tomógrafos convencionais, foram comparados pelo teste t, com os fornecidos pelos fabricantes, observando-se diferenças significativas para os três tomógrafos convencionais. A altura e espessura óssea corrigidas pela ampliação do guia radiográfico apresentaram diferenças estatisticamente significativas (p<0,05) pelo teste de Dunnett para as medidas do tomógrafo computadorizado Somatom Esprit quando comparadas com as dimensões reais. A medida da altura óssea corrigida com o fator de magnificação fornecido pelo fabricante demonstrou diferenças para os tomógrafos (p<0,05) com exceção do tomógrafo computadorizado Toshiba X vision EX, e para espessura óssea observou-se diferenças para o tomógrafo Quint Sectograph e Somatom Esprit quando comparados com as dimensões reais (p<0,05). Concluiu-se que as diferenças de magnificação calculadas, comparadas com as fornecidas pelos fabricantes não possuem significância clínica. As mensurações da altura e espessura ósseas foram precisas com exceção das realizadas no tomógrafo computadorizado com reconstrução multiplanar Somatom Sprit / Abstract: The magnification factors of conventional tomography was identified and compared them to the factors provided by the manufacturers, and the reliability of linear measurements achieved on corrected tomographic images, when compared to the real measurements on the bone segments. Sixteen dry edentulous human mandibles were used, and the area corresponding to the incisors, canines, premolars and molars were selected bilaterally. A 5.0-mm long orthodontic wire was fixated on the bone crest and buccal region of each area, to be used as a radiographic guide. The equipments used in this study were the conventional tomography Quint Sectograph, Orthopantomograph OP100, X Mind TOME, and the computerized tomography Somatom Esprit with multiplanar reconstruction and Toshiba X Vision EX with the Denta Scan software. The mandibles were positioned on the conventional scanners following the manufacturers¿ instructions, and the images were obtained. As to the computerized scanners, the mandibles were positioned with their bases perpendicular to the ground, and axial images were achieved for later oblique-sagittal reconstruction of the regions. After achievement of the images, the bone height and thickness of each region were measured, with correction of measurements based on the magnification of the radiographic guide and then according to the magnification factor supplied by the manufacturer. The mandibles were sectioned at the selected areas and bone height and thickness were directly measured, for achievement of the real values for each region. The magnification factors calculated by utilization of the radiographic guide for the conventional tomography were compared to those provided by the manufacturers by the t test, which revealed significant differences for the three conventional scanners. The bone height and thickness with correction according to magnification of the radiographic guide presented statistically significant differences (p<0.05) according to the Dunnett test for the measurements achieved on the computerized tomography Somatom Esprit compared to the real dimensions. The bone height corrected according to the magnification factor provided by the manufacturer demonstrated differences for the scanners (p<0.05), except for the computerized tomography Toshiba X vision EX, with differences in bone thickness for the Quint Sectograph and Somatom Esprit tomography compared to the real dimensions (p<0.05). It was concluded that differences between the magnification factors calculated compared to those provided by the manufacturers do not have any clinical implication; also, measurements of bone height and thickness were reliable, except for those achieved on the computerized tomography with multiplanar reconstruction Somatom Sprit / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica

Page generated in 0.0759 seconds