• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 1
  • Tagged with
  • 39
  • 39
  • 16
  • 12
  • 11
  • 11
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estampagem incremental do titânio comercialmente puro àplicação em implante craniano

Castelan, Jovani January 2010 (has links)
Este trabalho apresenta um estudo sobre o uso do processo de estampagem incremental empregando chapas de titânio comercialmente puro. O modelo do componente empregado como foco do trabalho foi um implante craniano a base de titânio. Este tipo de implante é usado, por exemplo, em casos de acidentes em que a camada óssea do crânio foi perdida. Com auxílio de um sistema computacional CAD (Computer Aided Design), foi desenvolvido um modelo 3D, a partir de imagens de tomografia computadorizada. Foram determinadas as características mecânicas e biomédicas das chapas de titânio F67 - grau 2 e, através de software CAM, foi possível gerar as trajetórias de ferramenta, utilizadas na usinagem do molde e na estampagem da chapa. Os testes práticos demostraram que a estampagem incremental proporcionou maiores deformações do que a estampagem convencional e qual a estratégia de usinagem que proporcionou a maior homogeneidade na distribuição de espessura e conformidade dimensional das chapas estampadas. / This work present a research about the incremental sheet forming process, using commercially pure titanium sheets. The model of component used like focus on work was a titanium cranial implant. This kind of implant is used, e.g., in cases of accidents where skull bone was lost. With aided of a CAD computacional system (Computer Aided Design), was development a 3D model, with images of computadorized tomography. It was determined the mechanical and biomedical properties of the F67 grade 2 titanium sheet and, through CAM software, it was possible development the tool path, used in the milling mold and sheet forming. The pratical tests showed the incremental forming provided greater than convencional forming and which the tool movement strategy that provided better homogeneity in the thickness distribution and dimensional conformity of the forming sheets.
32

Estampagem incremental do titânio comercialmente puro àplicação em implante craniano

Castelan, Jovani January 2010 (has links)
Este trabalho apresenta um estudo sobre o uso do processo de estampagem incremental empregando chapas de titânio comercialmente puro. O modelo do componente empregado como foco do trabalho foi um implante craniano a base de titânio. Este tipo de implante é usado, por exemplo, em casos de acidentes em que a camada óssea do crânio foi perdida. Com auxílio de um sistema computacional CAD (Computer Aided Design), foi desenvolvido um modelo 3D, a partir de imagens de tomografia computadorizada. Foram determinadas as características mecânicas e biomédicas das chapas de titânio F67 - grau 2 e, através de software CAM, foi possível gerar as trajetórias de ferramenta, utilizadas na usinagem do molde e na estampagem da chapa. Os testes práticos demostraram que a estampagem incremental proporcionou maiores deformações do que a estampagem convencional e qual a estratégia de usinagem que proporcionou a maior homogeneidade na distribuição de espessura e conformidade dimensional das chapas estampadas. / This work present a research about the incremental sheet forming process, using commercially pure titanium sheets. The model of component used like focus on work was a titanium cranial implant. This kind of implant is used, e.g., in cases of accidents where skull bone was lost. With aided of a CAD computacional system (Computer Aided Design), was development a 3D model, with images of computadorized tomography. It was determined the mechanical and biomedical properties of the F67 grade 2 titanium sheet and, through CAM software, it was possible development the tool path, used in the milling mold and sheet forming. The pratical tests showed the incremental forming provided greater than convencional forming and which the tool movement strategy that provided better homogeneity in the thickness distribution and dimensional conformity of the forming sheets.
33

Estampagem incremental do titânio comercialmente puro àplicação em implante craniano

Castelan, Jovani January 2010 (has links)
Este trabalho apresenta um estudo sobre o uso do processo de estampagem incremental empregando chapas de titânio comercialmente puro. O modelo do componente empregado como foco do trabalho foi um implante craniano a base de titânio. Este tipo de implante é usado, por exemplo, em casos de acidentes em que a camada óssea do crânio foi perdida. Com auxílio de um sistema computacional CAD (Computer Aided Design), foi desenvolvido um modelo 3D, a partir de imagens de tomografia computadorizada. Foram determinadas as características mecânicas e biomédicas das chapas de titânio F67 - grau 2 e, através de software CAM, foi possível gerar as trajetórias de ferramenta, utilizadas na usinagem do molde e na estampagem da chapa. Os testes práticos demostraram que a estampagem incremental proporcionou maiores deformações do que a estampagem convencional e qual a estratégia de usinagem que proporcionou a maior homogeneidade na distribuição de espessura e conformidade dimensional das chapas estampadas. / This work present a research about the incremental sheet forming process, using commercially pure titanium sheets. The model of component used like focus on work was a titanium cranial implant. This kind of implant is used, e.g., in cases of accidents where skull bone was lost. With aided of a CAD computacional system (Computer Aided Design), was development a 3D model, with images of computadorized tomography. It was determined the mechanical and biomedical properties of the F67 grade 2 titanium sheet and, through CAM software, it was possible development the tool path, used in the milling mold and sheet forming. The pratical tests showed the incremental forming provided greater than convencional forming and which the tool movement strategy that provided better homogeneity in the thickness distribution and dimensional conformity of the forming sheets.
34

Análise da resistência à corrosão e ao desgaste do aço inoxidável austenítico ASTM F 138 tratado por laser / Corrosion and wear resistance analysis of ASTM F 138 austenitic stainless steel treated by laser

Larosa, Maria Aparecida 16 August 2018 (has links)
Orientador: Maria Clara Filippini Ierardi / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-16T17:12:39Z (GMT). No. of bitstreams: 1 Larosa_MariaAparecida_D.pdf: 10660809 bytes, checksum: a977970425db7202c5a36a0e2a30a789 (MD5) Previous issue date: 2010 / Resumo: No presente trabalho, o aço inoxidável austenítico ASTM F 138, empregado na fabricação de implantes ortopédicos temporários e permanentes, foi submetido a tratamento de superfície por laser, com o intuito de analisar as modificações microestruturais resultantes deste tratamento e seus efeitos na resistência à corrosão e ao desgaste microabrasivo. A caracterização microestrutural foi feita por microscopia óptica, microscopia eletrônica de varredura, microdureza Vickers e difração de raios-X. Para analisar o comportamento em corrosão do aço, antes e após o tratamento, foram realizados três tipos diferentes de ensaios eletroquímicos usando solução de Ringer como eletrólito. O comportamento em desgaste foi avaliado a partir de ensaios por microabrasão do tipo esfera-sobre-placa, utilizando como abrasivos uma suspensão de partículas de carboneto de silício (SiC) em água destilada e uma suspensão de SiC em solução de Ringer. Após o tratamento por laser, o aço apresentou uma microestrutura refinada constituída por dendritas de austenita, com um aumento de aproximadamente 23% na dureza e com melhoria frente à corrosão e ao desgaste. / Abstract: In this work, ASTM F 138 austenitic stainless steel, used in temporary and permanent orthopaedic implants manufacture, was subjected to laser surface treatment. The purpose is analyze the microstructural changes resulting from this treatment and their effects on the microabrasive wear and corrosion resistance. The microstructural characterization was performed by optical microscopy, scanning electron microscopy, Vickers microhardness and X-ray diffraction. In order to analyze the corrosion behavior, three different types of electrochemical tests were carried out before and after treatment, using Ringer's solution as electrolyte. The wear behavior was evaluated using ball-cratering microabrasive wear tests, using slurry of silicon carbide particles (SiC) in distilled water and slurry of SiC in Ringer's solution. After laser treatment, the steel presented a refined microstructure consisted of austenite dendrites, with a 23% hardness increase and improved corrosion and wear resistance. / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
35

Estudo de tratamentos térmicos e acabamentos de superfície na liga Ti-6Al-4V produzida via DMLS para aplicação em implantes / Study of heat treatments and surface finishes in Ti-6Al-4V alloy produced by DMLS for use in implants

Longhitano, Guilherme Arthur, 2015 26 August 2018 (has links)
Orientador: Maria Clara Filippini Ierardi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-26T21:12:43Z (GMT). No. of bitstreams: 1 Longhitano_GuilhermeArthur_2015_M.pdf: 10352364 bytes, checksum: 6157c8c85d67a80202c0078ff2bd5901 (MD5) Previous issue date: 2016 / Resumo: No presente trabalho, a liga de titânio Ti-6Al-4V, empregada em implantes ortopédicos permanentes ou temporários devido à sua biocompatibilidade, foi produzida a partir da manufatura aditiva utilizando o processo de Sinterização Direta de Metais por Laser (DMLS). O material foi submetido a diferentes tratamentos térmicos com o intuito de modificar suas propriedades mecânicas, e a acabamentos de jateamento, ataque químico e polimento eletroquímico para analisar os efeitos dos mesmos no acabamento de superfície. As modificações resultantes após os tratamentos térmicos e acabamentos de superfície foram analisadas por microscopia óptica, microscopia eletrônica de varredura, difração de raios-X, medidas de rugosidade e massa, microdureza Vickers, e ensaios de tração e compressão. No estudo de acabamentos de superfície, o menor valor de rugosidade foi obtido após as etapas de jateamento e ataque químico combinadas. O acabamento de jateamento é responsável por deixar uma superfície com rugosidade uniforme, enquanto o ataque químico é responsável pela limpeza da superfície e redução da rugosidade. As amostras foram submetidas aos tratamentos térmicos nas temperaturas de 850 ºC, 950 ºC e 1050 ºC durante uma hora com resfriamento em forno. Foi constatado que quanto maior a temperatura empregada, maior é a ductilidade do material e, por outro lado, menor é a resistência mecânica. Tal fato ocorreu devido à maior nucleação e crescimento da fases 'alfa' e 'beta' no material, que apresentava inicialmente uma estrutura constituída por martensita hexagonal ('alfa'). A condição de tratamento térmico a 950 ºC foi a que apresentou a melhor relação de propriedades mecânicas, satisfazendo os requerimentos da norma ASTM F136 para a utilização da liga Ti-6Al-4V em implantes / Abstract: In this study, the Ti-6Al-4V titanium alloy, used in permanent or temporary orthopedic implants due to its biocompatibility, was produced by additive manufacturing using the Direct Metal Laser Sintering (DMLS) process. The material was subjected to different heat treatments in order to modify their mechanical properties, and to the surface finishes of blasting, chemical etching and electropolishing to analyze their effects on surface finish. The resulting changes after the heat treatments and surface finishes were analyzed by optical microscopy, scanning electron microscopy, X-ray diffraction, roughness and mass measurements, Vickers microhardness, and tensile and compression tests. In surface finishes study, the lowest roughness value was obtained after the combined steps of blasting and chemical etching. The blasting finish is responsible for leaving a surface with uniform roughness, while the chemical etching is responsible for cleaning the surface and reducing roughness. The samples were subjected to heat treatments at temperatures of 850 °C, 950 °C and 1050 °C for one hour followed by furnace cooling. It has been found that the higher the temperature employed, the higher the ductility of the material and, on the other hand, the lower the mechanical strength. This happened due to increased nucleation and growth of 'alfa' and 'beta' phases in the material, which initially had a structure made of hexagonal martensite ('alfa'). The condition of heat treatment at 950 ° C showed the best relation of mechanical properties, meeting the requirements of ASTM F136 for the use of Ti-6Al-4V alloy in implants / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
36

Transformações de fases e relação entre microestrutura e propriedades mecânicas de ligas Ti-Nb-Fe para aplicações biomédicas : concepção de implantes ortopédicos com rigidez gradual / Phase transformation and relationship between microstructure and mechanical properties of Ti-Nb-Fe for biomedical applications : design of orthopedic implants with graded stiffness

Lopes, Éder Sócrates Najar, 1982- 23 August 2018 (has links)
Orientador: Rubens Caram Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-23T09:33:56Z (GMT). No. of bitstreams: 1 Lopes_EderSocratesNajar_D.pdf: 9279894 bytes, checksum: a2ed77cd79f48134e7daf5bc705afb0e (MD5) Previous issue date: 2013 / Resumo: Ligas de Ti do tipo ? metaestável exibem comportamento singular no tocante à possibilidade de manipulação de seu comportamento mecânico. Nessas ligas, a rigidez pode ser alterada por meio do controle das fases presentes, o que permite que esses materiais sejam incluídos no seleto grupo dos materiais com gradientes funcionais (functionally graded materials - FGM). Neste trabalho, objetivou-se projetar, produzir, processar, caracterizar e aplicar ligas Ti-Nb com adições do elemento ? estabilizador de baixo custo Fe. As ligas foram produzidas por fusão a arco voltaico e submetidas a diversas condições de tratamento térmico, incluindo solubilização acima da temperatura ?-transus, resfriamento rápido até a temperatura ambiente e tratamentos térmicos de envelhecimento entre 260 °C e 400 °C. A caracterização envolveu calorimetria diferencial de varredura, difração de raios-X e dureza Vickers em alta temperatura, análises metalográficas e de módulo de elasticidade por técnicas acústicas, ensaios de tração e mapeamento de rigidez por meio de nanoindentação. Os resultados obtidos mostram a retenção completa da fase ? para a liga Ti-30Nb-3Fe solubilizada e resfriada rapidamente e permitem também, compreender a decomposição da fase martensita ?" e a nucleação das fases ? e ?. A adição do elemento Fe tornou a cinética de transformação de fases bem mais lenta, propiciando, sob algumas condições, a supressão da fase ?, que é conhecida por aumentar a dureza em detrimento da ductilidade. Tais resultados foram utilizados no estabelecimento de condições ideais de processamento que permitem obter componentes ortopédicos com rigidez gradual. Finalmente, o conhecimento adquiro foi usado na fabricação de placas e parafusos de osteossíntese a partir da liga Ti-30Nb-3Fe com gradientes de funcionalidade / Abstract: Metastable ? Ti alloys exhibit singular behavior regarding the possibility of manipulating their mechanical behavior. In these alloys, the stiffness can be changed by controlling phases, which allows these materials to be included in the select group of functionally graded materials (FGM). This study aimed to design, produce, process, characterize and apply Ti-Nb alloys with addition of Fe, an inexpensive ? stabilizing element. These alloys were produced by arc melting and subjected to different heat treatment conditions, including solution above the ?- transus temperature, quenching to room temperature and aging heat treatments between 260 °C and 400 °C. Characterization involved differential scanning calorimetry, X-ray diffraction and Vickers hardness at high temperature, metallographic analyzes, elastic modulus by acoustic techniques, tensile test and stiffness mapping via nanoindentation. The results obtained show complete retention of the ? phase in the Ti-30Nb-3Fe alloy after solution in the ? field and rapid cooling to room temperature and also allow understanding martensite ?" decomposition and nucleation of the ? and ? phases. It was found that Fe additions make the phase transformation kinetics much slower, providing, for some conditions, suppression of the ? phase precipitation, which is known to increase the hardness at the expense of ductility. These results were used to establish optimal processing conditions, resulting in orthopedic component with graded stiffness. Finally, the knowledge acquired was used in the manufacturing of osteosynthesis plates and screws with functionality graded from the Ti-30Nb-3Fe / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
37

Desenvolvimento de filmes de carbono tipo diamante (DCL) obtidos pelo processo de imersão em plasma para implantes osteoarticulares / Development of diamond-like carbon (DCL) coatings produced by plasma immersion process for orthopaedic implants

Uzumaki, Emilia Tieko 24 February 2006 (has links)
Orientador: Cecilia A. C. Zavaglia / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-07T02:27:14Z (GMT). No. of bitstreams: 1 Uzumaki_EmiliaTieko_D.pdf: 44142340 bytes, checksum: e8db433907d2fd2f88b260ed4cd8a791 (MD5) Previous issue date: 2006 / Resumo: O carbono tipo diamante ("diamond-like carbon" - DLC) tem demonstrado características, como alta dureza, baixo atrito, resistência ao desgaste e à corrosão, e biocompatibilidade, que podem melhorar as propriedades de implantes sólidos e articulados. O processo de imersão em plasma vem sendo usado para depositar DLC em substratos tridimensionais, pois, com esta técnica, se consegue melhor adesão do que com as técnicas convencionais. Neste trabalho, filmes de DLC foram depositados, pelo processo de imersão em plasma, em lamínulas de vidro, silício e liga de titânio Ti-13Nb-13Zr. A caracterização da microestrutura, morfologia, dureza e adesão dos filmes de DLC foi feita por espectroscopia Raman, microscopia eletrônica de varredura (MEV), microscopia de força atômica (MFA), nanoindentação e ensaio de puxamento. Como exemplos de peças tridimensionais, filmes de DLC foram depositados em implantes osteoarticulares de quadril e joelho, titânio poroso (esponja de célula-aberta, semelhante à estrutura do osso esponjoso, expandida a vácuo), facas industriais, bisturi cirúrgico, engrenagem de motor, tubos de quartzo e de alumínio, e outros objetos. O filme obtido apresentou boas propriedades mecânicas, aumentando em 2 vezes a dureza da liga de Ti, alta adesão (filme sem interface definida e sem delaminação), resistência ao desgaste, baixa rugosidade e uniformidade de deposição em superfícies tridimensionais. Os resultados de corrosão (polarização de Tafel e espectroscopia de impedância eletroquímica em fluido corporal simulado) mostraram que o revestimento de DLC melhora a resistência da liga de Ti à corrosão. No ensaio de biocompatibilidade in vitro, com células fibroblásticas, foram estudados a citotoxicidade, adesão e morfologia celular (estudo citoquímico, microscopia de contraste de fase, MEV e MFA). No ensaio de biocompatibilidade in vivo, a liga de Ti-13Nb-13Zr, revestida com DLC, foi investigada em tecido muscular e ósseo de ratos após 4 e 12 semanas do procedimento cirúrgico. A interface formada entre o DLC e o tecido foi investigada por histologia convencional, e os implantes retirados por MEV. A interface entre o implante e o tecido ósseo, não descalcificado, foi estudada por MEV na modalidade retroespalhamento. Os resultados mostraram a biocompatibilidade in vitro e in vivo do filme de DLC, e foi verificado também que os implantes revestidos com DLC possuem resposta biológica mais favorável do que os implantes não revestidos / Abstract: Diamond-like carbon (DLC) films are often considered a suitable coating material for orthopaedic applications. It has proven characteristics, such as hardness, wear resistance, low friction coefficient and biocompatibility that improve the properties of solid and articulated implants. Recently, the plasma immersion process was used to deposit DLC films with superior adhesion properties to those prepared with conventional techniques. DLC coatings were deposited on glass coverslips, silicon (Si) and Ti-13Nb-13Zr substrates using the plasma immersion process. The microstructure, morphology, roughness, hardness and adhesion of DLC films were characterized using Raman spectroscopy, scanning electron microscopy (SEM), atomic force microscopy (AFM), nanoindentation and pull-test. As examples, DLC films produced by plasma immersion were deposited on industrial knives, surgical knives, knee implants, femoral heads (of hip prostheses), titanium foams, transmission gears of motorcycles, aluminium pipes, quartz pipes, and others objects. The corrosion susceptibility of DLC coatings produced by plasma immersion was studied in a simulated body fluid environment (Hanks' solution) using polarization test and electrochemical impedance spectroscopy (EIS). Electrochemical results showed that DLC coating produced by plasma immersion could improve corrosion resistance, and no significant damage has been observed. Vero cells (fibroblasts) were utilized for the in vitro biocompatibility studies, by cytotoxicity, adhesion and cell morphology (phase contrast microscopy, SEM, AFM, and cytochemical study). DLC-coated Ti-13Nb-13Zr was investigated in an animal model using the muscular tissue and femoral condyles of rats for intervals of 4 and 12 weeks postoperatively. The interface between the implants and tissue were analysed by light microscopy, and the removed implants by SEM. The SEM by backscattering was used to access the interface between the implants the bone tissue without decalcifying. Our results indicate that DLC coatings are biocompatible in vitro and in vivo / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
38

ESTUDO DA RECRISTALIZAÇÃO DINÂMICA DURANTE A DEFORMAÇÃO A QUENTE DE UM AÇO ISO 5832-9 / STUDY OF THE DYNAMIC RECRYSTALLIZATION DURING THE DEFORMATION THE HOT ONE OF A STEEL ISO 5832-9

Nascimento, Luciene Araujo 25 February 2010 (has links)
Made available in DSpace on 2016-08-18T18:19:27Z (GMT). No. of bitstreams: 1 LUCIENE ARAUJO NASCIMENTO.pdf: 1402629 bytes, checksum: b9ce204098b2c4fe0362b6792a692744 (MD5) Previous issue date: 2010-02-25 / FUNDAÇÃO DE AMPARO À PESQUISA E AO DESENVOLVIMENTO CIENTIFICO E TECNOLÓGICO DO MARANHÃO / Austenitic stainless steels have low economic value compared to titanium and its alloys, considered the most resistant to corrosion in biological environment, and for over fifty years are widely used in the manufacture of orthopedic implants, particularly in public health service. Currently the ISO 5832-1 steel (ASTM F 138) is the most used in the manufacture of orthopedic prosthesis, especially the temporary ones. However, because it is susceptible to localized corrosion when in contact with human tissue, it is being gradually replaced by austenitic stainless steel of low carbon and high nitrogen called ISO 5832-9. The same is already used extensively in Europe and the United States, while in Brazil it's use is more recent and smaller scale. This work investigates the behavior of dynamic recrystallization in an ISO 5832-9 steel through hot torsion tests and optical microscopy, for different conditions of temperature, strain and strain rate. It was found through the plastic flow curves of the studied material crystallizes dynamically and that the high value of its apparent activation energy for deformation can be attributed to the presence of a large amount of precipitated particles and nitrogen dissolved in the matrix. Micrographs confirmed that tests carried out at low temperatures reveal a strong retardation of dynamic recrystallization. Moreover, the presence of serrated grain boundaries and nucleation of new grains in the old deformed grain boundaries, are strong indications that the recrystallization occurred by a necklace mechanism. The behavior of the average recrystallized grain size, DDRX, with temperature resembles the behavior of the austenitic grain growth in microalloyed steels. The presence of a minimum in the behavior of DDRX with the strain rate can be attributed to a minimum strain rate required to cause the greatest amount of dynamics precipitation. / Os aços inoxidáveis austeníticos possuem um baixo valor econômico quando comparados ao titânio e suas ligas, considerados os mais resistentes à corrosão em meio biológico, e há mais de cinquenta anos são amplamente utilizados na confecção de implantes ortopédicos, em especial no serviço de saúde pública. Atualmente o aço ISO 5832-1 (ASTM F 138) é o mais utilizado na confecção de próteses ortopédicas, principalmente as temporárias. Entretanto, devido o mesmo ser suscetível à corrosão localizada quando em contato com tecido humano, ele está sendo gradativamente substituído pelo aço inoxidável austenítico de baixo teor de carbono e alto teor de nitrogênio denominado de ISO 5832-9. O mesmo já é utilizado em larga escala na Europa e nos Estados Unidos, enquanto no Brasil a sua utilização é mais recente e em menor escala. Este trabalho investiga o comportamento da recristalização dinâmica em um aço ISO 5832-9, através de ensaios de torção a quente e microscopia ótica, para diferentes condições de temperatura, deformação e taxa de deformação. Foi constatado através das curvas de escoamento plástico que o material estudado recristaliza dinamicamente e, que o alto valor da sua energia de ativação aparente para a deformação pode ser atribuído à presença de uma grande quantidade de partículas de precipitados e ao nitrogênio em solução na matriz. Micrografias confirmam que ensaios realizados a baixas temperaturas revelam um forte retardamento da recristalização dinâmica. Além disso, a presença de contornos de grão serrilhados e nucleação de novos grãos nos antigos contornos de grãos deformados, são fortes indícios de que a recristalização ocorreu por mecanismo colar. O comportamento do tamanho de grão médio recristalizado, DDRX, com a temperatura, se assemelha ao comportamento do crescimento de grão austeníticos de aços microligados. A presença de um mínimo no comportamento do DDRX com a taxa de deformação pode ser atribuído a uma taxa de deformação mínima necessária para que ocorra a maior quantidade de precipitação dinâmica.
39

Propriedades de corrosão e caracterização química – metalográfica de próteses em aços inoxidáveis ISO 5832-9 e F138, removidas de pacientes

Silva, Elison da Fonseca e 26 November 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-05-03T13:18:17Z No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-13T13:33:58Z (GMT) No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) / Made available in DSpace on 2017-05-13T13:33:58Z (GMT). No. of bitstreams: 1 elisondafonsecaesilva.pdf: 5310395 bytes, checksum: c89f2c8b3846fc7ab92440accf66f534 (MD5) Previous issue date: 2010-11-26 / Este trabalho estudou a composição química e metalográfica (microestrutura, tamanho de grão, teor de inclusões) de aços inoxidáveis austeníticos, desenvolvidos para aplicações como biomateriais, utilizados na fabricação de implantes ortopédicos, removidos de pacientes afetados por quadro inflamatório, e comparou as superfícies das amostras, através da Microscopia Eletrônica de Varredura (MEV) após ataque eletroquímico. Os resultados da análise química, por Espectrometria de Emissão Ótica e Microanálise por Dispersão de Energia (EDS), mostraram que todos os grupos apresentaram conformidade com as normas ASTM F138-92 e ABNT NBR ISO 5832-9:2008. O tamanho de grão foi determinado por Microscopia Ótica e Microscopia Eletrônica de Varredura (MEV). As superfícies das amostras foram analisadas por Microscopia Eletrônica de Varredura (MEV), depois de serem submetidos a ensaio de polarização cíclica potenciodinâmica em potencial de 50 mV após a região passiva em meio de solução de Ringer Lactato e solução de NaCl 0,9 mol.L-1na temperatura de 36,5 oC. Essas análises por MEV foram conduzidas nas amostras para identificar o tipo de corrosão apresentada. Concluiu-se que todos os implantes apresentavam tamanho de grão superior ao recomendado pela norma. Constatou-se também a presença de ferrita delta em oito dos doze implantes removidos, que de acordo com a norma ASTM 138-92, não deveria ser percebida microscopicamente com um aumento de 100 vezes. Verificou-se ainda que em meio de NaCl, o aço ISO 5832-9 ao contrário do aço F138, não apresentou nenhuma forma de corrosão localizada. Em solução de Ringer lactato, após ataque por 15 min. no potencial de 1000 mV/ECS foi notada a presença de pites no aço ISO 5832-9. O ensaio de polarização cíclica revelou que um dos aços, identificado como ISO 5832 9 apresentou resistência à corrosão localizada muito superior ao outro identificado como F 138, além de não liberar íons metálicos nas soluções eletrolíticas. Essa propriedade é principalmente atribuída ao aumento da estabilidade do filme passivo, que por sua vez, é favorecida pela presença do nitrogênio em solução sólida intersticial na austenita do aço ISO 5832-9. Os ensaios de polarização revelaram-se úteis para indicar a baixa resistência à corrosão por pites exibida “in-vitro” pelas próteses. As amostras do aço F 138 após serem submetidas ao ensaio eletroquímico em solução de Ringer lactato apresentaram perdas de 63% de níquel e 26% de ferro em relação à composição inicial. Tais elementos foram deslocados eletroquimicamente na forma iônica para a solução de Ringer lactato, onde formaram precipitados sendo, portanto, um forte indicador de que as reações sofridas pelos portadores das próteses foram motivadas por esses íons metálicos, que são posteriormente incorporados no organismo. Pretende-se com os resultados dessa pesquisa propor aos órgãos governamentais reguladores de normas técnicas e de vigilância sanitária, bem como a médicos e hospitais que exijam dos fabricantes de próteses de aços inoxidáveis laudos técnicos que atestem a qualidade dos implantes, onde cada lote de fabricação das peças seja acompanhado por certificados garantindo a composição química e as características metalográficas especificadas pelas norma existentes no Brasil. / This work has studied the chemical and metallographic composition (microstructure, grain size, inclusion rate) of austenitic stainless steels which were developed to be applied as biomaterials, and used in the production of orthopedical implants, removed from patients which had been affected by inflammation; it has also been compared the sample surfaces, by means of scanning electronic microscopy (SEM) after electrochemical attack. The results of chemical analysis, performed by optical emission spectroscopy and Energy Dispersive Spectroscopy (EDS) have shown that all samples are in agreement with the ASTM F138-92 e ABNT NBR ISO 5832-9:2008 regulations, whereas the grain size has been determined by optical microscopy and SEM. The surfaces of the samples were analyzed by SEM and EDS techniques; samples were submitted to potentiodynamic cyclic polarization tests in 50 mV potential after the passivation region in Ringer lactate and NaCl 0,9 mol.L-1 solutions at 36,5C; such SEM measurements were done to identify the type of corrosion over the samples. It has been concluded that all implants showed average grain sizes above the recommended by the regulations; also the presence of delta ferrite in eight of the twelve investigated implants has been seen, which according to the ASTM 138-92 regulation this would not been possible even with a 100-fold increase at the optical microscope. It has also been verified that in NaCl medium the ISO 5832-9 steel did not present any kind of localized corrosion, instead of F 138 steel; in Ringer lactate solution, after 15 minutes attack at 1000mV/SCE, has been noted the presence of pits for ISO 5832-9 steel. The cyclic polarization measurements have revealed that one of the investigated steels, named ISO 5832-9, presented a very high resistance to localized corrosion when compared to the F 138 samples, besides they did not release metallic ions to the electrolytic solutions. This characteristic can be mainly attributed to the increasing of the passivation film stability, which is also favored by the presence of nitrogen atoms in the solid solution composing the structure of ISO 5832-9 steel. The pit corrosion tests have shown very useful to indicate the low resistance to pit corrosion, present “in-vitro” in all the studied samples. The EDS mapping analysis of F 138 samples, submitted to electrochemical attack in Ringer lactate medium, have shown a loss of 63% of nickel and 26% of iron, when compared to the initial composition; such metals were electrochemically solubilized to the Ringer lactate solution, where they can probably precipitate from the solution, being a strong indication that the reactions taking place in the patients have been motivated by these metal ions, which can be incorporated by the human body. The obtained results of this work are the basis of a tentative proposition to the governmental organisms which are the responsible for the regulation of the technical specifications for the prosthesis producers, requiring from them technical reports assuring the quality for the implant pieces, i.e., for each manufacturing lot a description or a special certificate containing the chemical composition and the metallographic characteristics specified by the Brazilian laws.

Page generated in 0.4883 seconds