• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 35
  • 23
  • 8
  • 8
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação, por meio de microtomografia computadorizada, da anatomia interna de incisivos inferiores / Internal anatomy of lower incisors evaluated by computerized microtomography

Leoni, Graziela Bianchi 26 January 2012 (has links)
O conhecimento do sistema de canais radiculares (SCR) é de fundamental importância para o sucesso do tratamento endodôntico. O objetivo deste estudo foi avaliar quantitativa e qualitativamente a anatomia do SCR de incisivos inferiores por meio de microtomografia computadorizada. A aquisição de fotomicrotomografia de 283 incisivos centrais (ICI) e 329 incisivos laterais inferiores (ILI) foi realizada por meio do microtomógrafo SkyScan modelo 1174. Estas imagens foram utilizadas para classificação do SCR de acordo com Vertucci que considera número e localização da divisão dos canais, variando do tipo I ao VIII. Da amostra inicial, 39 ICI e 35 ILI foram escaneados com resolução de 22,9 μm e reconstruídos para análises bidimensionais de: número, área, circularidade, diâmetro maior e menor a 1, 2, 3, 4 e 5 mm do forame apical; e análise tridimensional onde foram observados volume e área de superfície, número e localização de canais acessórios e classificação de acordo com Vertucci. Os resultados evidenciaram que, no terço apical, o número máximo de canais encontrados foi 3; a área aumentou progressivamente a cada milímetro avaliado; a circularidade variou entre 0,37 ± 0,21 (mínimo) e 0,52 ± 0,19 (máximo) demonstrando uma forma achatada destes canais; o diâmetro maior aumentou 95,45% nos ICI e 135,55% nos ILI enquanto o diâmetro menor aumentou 36,36% nos ICI e 66,67% nos ILI. A análise tridimensional revelou que em 76,92% dos ICI e 85,71% dos ILI foi possível a classificação de acordo Vertucci, com maior predominância do tipo I, com canal único, em 46,15% dos ICI e 54,29% dos ILI. Em 15,39% dos ICI e 11,43% de ILI foram identificadas dez novas morfologias. A média do volume (mm3) e da área de superfície (mm2) foram, respectivamente, de 4,38 ± 1,97 e 35,59 ± 11,72 para os ICI e 4,74 ± 1,33 e 38,91 ± 9,56 para os ILI. Os canais acessórios foram observados apenas no terço apical em 46,15% dos ICI e 28,57% dos ILI. Conclui-se que a microtomografia é um método não destrutivo, reprodutível e confiável para estudo de anatomia interna, sendo identificados dez novos tipos morfológicos de SCR de incisivos inferiores. / The knowledge of the root canal system (RCS) is of utmost importance to achieve success in the root canal treatment. The purpose of this study was to evaluate qualitative and quantitatively the RCS anatomy of mandibular incisors by means of microcomputed tomography. The image acquisition of 283 mandibular central incisors (MCI) and 329 mandibular lateral incisors (MLI) was performed using the SkyScan 1174 microtomography device. These images were used to classify the RCS from type I to VIII, considering the number and location of the canals, according to Vertuccis classification. From this sample, thirty-nine MCI and thirty-five MLI were scanned with a resolution of 22.9 μm and reconstructed in order to evaluate the number and location of the main and accessory canals, according to Vertucci\'s classification, the bidimensional parameters of area, roundness, major and minor diameters of the root canal at 1, 2, 3, 4 and 5 mm from the apical foramen, as well as the three-dimensional analysis of volume and surface area. In the apical third, it was found up to three root canals; the area progressively increased from the apical foramen; the roundness ranged from 0.37 ± 0.21 to 0.52 ± 0.19 demonstrating the flat-oval shape of the canals; the major and minor diameters increased 95.45% and 36.36% in the MCI and 135.55% and 66.67% in the MLI, respectively. The threedimensional analysis revealed that in 76.92% of MCI and 85.71% of MLI the RCS could be classified according to Vertucci\'s, and type I (one root canal) was found in 46.15% and 54.29% of MCI and MLI, respectively. Ten new types of root canal morphologies were observed in 15.39% of MCI and 11.43% of MLI. The mean volume (mm3) and surface area (mm2) were 4.38 ± 1.97 and 35.59 ± 11.72 in the MCI, and 4.74 ± 1.33 and 38.91 ± 9.56 in the MLI, respectively. Accessory canals were observed only in the apical third in 46.15% of MCI and 28.57% of MLI. It was concluded that the microtomography is a non-destructive, reproducible and reliable method for the study of the RCS that allowed the identification of ten new types of root canal morphologies in mandibular incisors.
22

Fatores que influenciam o manchamento marginal e superficial de restaurações de resina composta em dentes anteriores / Factors afeting marginal staining and surfasse staining of composite restoratios in anterior teeth

Silva, Paula Barcellos da 26 February 2015 (has links)
Submitted by Márcio Ropke (ropke13marcio@gmail.com) on 2017-06-14T13:42:31Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Fatores que influenciam o manchamento marginal e superficial de.pdf: 1050448 bytes, checksum: 6c04b94def0824534826c608686b39e3 (MD5) / Made available in DSpace on 2017-06-14T13:42:31Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Fatores que influenciam o manchamento marginal e superficial de.pdf: 1050448 bytes, checksum: 6c04b94def0824534826c608686b39e3 (MD5) Previous issue date: 2015-02-26 / Sem bolsa / Procedimentos restauradores estéticos de resina composta são confeccionados diariamente nos consultórios odontológicos, porém poucos estudos reportam o acompanhamento clínico da longevidade destas restaurações. O intuito deste estudo foi avaliar fatores que influenciam no manchamento superficial e marginal de restaurações de resina composta realizadas em dentes anteriores, dentre eles: o tipo de resina composta e sistema adesivo utilizado, a confecção ou ausência de bisel no preparo e a aplicação de um gel hidrossolúvel na última camada de resina. A partir da análise dos prontuários da Disciplina de Estágio em Atividades Clínicas Odontológicas do Programa de Pós-Graduação em Odontologia da Universidade Federal de Pelotas, entre o período de 2013 a 2014, 52 pacientes foram convidados a participar do estudo. Aceitaram participar 33 pacientes, que receberam 69 restaurações estéticas (Classe IV, Classe III e Faceta). As restaurações foram avaliadas de acordo com os critérios de avaliação clínica de restaurações propostos pela FDI (Federação Dentária Internacional). Os dados obtidos foram tabulados e submetidos à análise estatística usando o Stata versão 11.0. As análises de sobrevida foram realizadas pelo método Kaplan-Meier, para obtenção das curvas de sobrevida para as variáveis de interesse, seguido pelo teste Log-Rank, para comparação entre os grupos (p<0.05). Das 69 restaurações avaliadas, somente 4 restaurações foram consideradas falhas estéticas. As restaurações em que o preparo cavitário foi realizado com bisel apresentaram melhores resultados em relação ao manchamento marginal do que as que não tiveram o bisel confeccionado (p=0.002). Restaurações Classe IV foram as que apresentaram maior número de falhas em relação ao manchamento marginal (p=0.024). Embora ambos os tipos de resina composta apresentaram-se clinicamente aceitáveis, houve diferença para manchamento marginal (p=0.05), onde qualitativamente a IPS Empress Direct apresentou melhores escores que a Filtek Z-350. O tipo de sistema adesivo (p=0.476) e a aplicação ou não de gel hidrossolúvel sobre a superfície das restaurações (p=0.651) não apresentaram diferenças significativas. Em conclusão, as restaurações avaliadas apresentaram-se satisfatórias após um ano de acompanhamento clínico, mas restaurações confeccionadas com bisel tiveram um melhor desempenho em relação ao manchamento marginal. / Esthetic restorative procedures with composite resins are carried out daily in the dental practice, but few studies reported on the clinical longevity of these restorations. The purpose of this study was to evaluate the factors that influence marginal and surface staining of resin composite restorations placed in anterior teeth, including: the type of composite resin and adhesive system used, the presence or absence of bevel in the preparation and implementation of a hydrosoluble gel in the last resin layer. From the analysis of the files of the Internship Course in Dental Clinics Activities of the Graduate Program in Dentistry from the Federal University of Pelotas, in the period from 2013 to 2014, 52 patients were invited. Thisty-three patients took part in the study, and 69 restorations (Class IV, Class III and direct veneer) were evaluated according to the clinical evaluation criteria for restorations’ evaluation proposed by the FDI (World Dental Federation). Retrieved data were tabulated and statistically analyzed using Stata version 11.0. Survival analyzes were performed using the Kaplan-Meier method, to obtain the survival functions for the variables of interest, followed by the log-rank test for comparison between groups (p <0.05). Out of the 69 evaluated restorations, only 4 restorations failed due to aesthetic issues. Restorations placed on cavity preparations with bevel at the cavo-surface angle showed better results in relation to marginal staining than those who have not been placed in beveled cavity preparation (p=0.002). Class IV restorations showed the highest number of failures (p=0.024). Although both types of composite resin were clinically acceptable, there was statistically significant difference between resins for marginal staining (p=0.05), where qualitatively the Empress had better scores than the Z-350.The type of adhesive system (p=0.476) and the application or not water-soluble gel showed no significant difference (p=0.651). The results of this study revealed that the restorations were acceptable after one year of clinical follow-up, but restorations that were placed in beveled cavity preparation performed better regarding the marginal staining.
23

Avaliação, por meio de microtomografia computadorizada, da anatomia interna de incisivos inferiores / Internal anatomy of lower incisors evaluated by computerized microtomography

Graziela Bianchi Leoni 26 January 2012 (has links)
O conhecimento do sistema de canais radiculares (SCR) é de fundamental importância para o sucesso do tratamento endodôntico. O objetivo deste estudo foi avaliar quantitativa e qualitativamente a anatomia do SCR de incisivos inferiores por meio de microtomografia computadorizada. A aquisição de fotomicrotomografia de 283 incisivos centrais (ICI) e 329 incisivos laterais inferiores (ILI) foi realizada por meio do microtomógrafo SkyScan modelo 1174. Estas imagens foram utilizadas para classificação do SCR de acordo com Vertucci que considera número e localização da divisão dos canais, variando do tipo I ao VIII. Da amostra inicial, 39 ICI e 35 ILI foram escaneados com resolução de 22,9 &mu;m e reconstruídos para análises bidimensionais de: número, área, circularidade, diâmetro maior e menor a 1, 2, 3, 4 e 5 mm do forame apical; e análise tridimensional onde foram observados volume e área de superfície, número e localização de canais acessórios e classificação de acordo com Vertucci. Os resultados evidenciaram que, no terço apical, o número máximo de canais encontrados foi 3; a área aumentou progressivamente a cada milímetro avaliado; a circularidade variou entre 0,37 ± 0,21 (mínimo) e 0,52 ± 0,19 (máximo) demonstrando uma forma achatada destes canais; o diâmetro maior aumentou 95,45% nos ICI e 135,55% nos ILI enquanto o diâmetro menor aumentou 36,36% nos ICI e 66,67% nos ILI. A análise tridimensional revelou que em 76,92% dos ICI e 85,71% dos ILI foi possível a classificação de acordo Vertucci, com maior predominância do tipo I, com canal único, em 46,15% dos ICI e 54,29% dos ILI. Em 15,39% dos ICI e 11,43% de ILI foram identificadas dez novas morfologias. A média do volume (mm3) e da área de superfície (mm2) foram, respectivamente, de 4,38 ± 1,97 e 35,59 ± 11,72 para os ICI e 4,74 ± 1,33 e 38,91 ± 9,56 para os ILI. Os canais acessórios foram observados apenas no terço apical em 46,15% dos ICI e 28,57% dos ILI. Conclui-se que a microtomografia é um método não destrutivo, reprodutível e confiável para estudo de anatomia interna, sendo identificados dez novos tipos morfológicos de SCR de incisivos inferiores. / The knowledge of the root canal system (RCS) is of utmost importance to achieve success in the root canal treatment. The purpose of this study was to evaluate qualitative and quantitatively the RCS anatomy of mandibular incisors by means of microcomputed tomography. The image acquisition of 283 mandibular central incisors (MCI) and 329 mandibular lateral incisors (MLI) was performed using the SkyScan 1174 microtomography device. These images were used to classify the RCS from type I to VIII, considering the number and location of the canals, according to Vertuccis classification. From this sample, thirty-nine MCI and thirty-five MLI were scanned with a resolution of 22.9 &mu;m and reconstructed in order to evaluate the number and location of the main and accessory canals, according to Vertucci\'s classification, the bidimensional parameters of area, roundness, major and minor diameters of the root canal at 1, 2, 3, 4 and 5 mm from the apical foramen, as well as the three-dimensional analysis of volume and surface area. In the apical third, it was found up to three root canals; the area progressively increased from the apical foramen; the roundness ranged from 0.37 ± 0.21 to 0.52 ± 0.19 demonstrating the flat-oval shape of the canals; the major and minor diameters increased 95.45% and 36.36% in the MCI and 135.55% and 66.67% in the MLI, respectively. The threedimensional analysis revealed that in 76.92% of MCI and 85.71% of MLI the RCS could be classified according to Vertucci\'s, and type I (one root canal) was found in 46.15% and 54.29% of MCI and MLI, respectively. Ten new types of root canal morphologies were observed in 15.39% of MCI and 11.43% of MLI. The mean volume (mm3) and surface area (mm2) were 4.38 ± 1.97 and 35.59 ± 11.72 in the MCI, and 4.74 ± 1.33 and 38.91 ± 9.56 in the MLI, respectively. Accessory canals were observed only in the apical third in 46.15% of MCI and 28.57% of MLI. It was concluded that the microtomography is a non-destructive, reproducible and reliable method for the study of the RCS that allowed the identification of ten new types of root canal morphologies in mandibular incisors.
24

Arco de intrusão de três peças com retração simultânea dos incisivos superiores : estudo em elementos finitos / Guilherme Ortellado ; orientador, Odilon Guariza Filho

Ortellado, Guilherme, 1977- January 2012 (has links)
Tese (doutorado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2012 / Inclui bibliografias
25

Influência de dois tipos de retentores intra-radiculares e do tipo de coroa total na resistência e modo de fratura de raízes de incisivos superiores

Zamboni, Sandra Regina Oliveira Costa [UNESP] 22 July 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-07-22Bitstream added on 2014-06-13T20:45:50Z : No. of bitstreams: 1 zamboni_sroc_dr_sjc.pdf: 562964 bytes, checksum: 96289338fffdaef0884f0ad0364b5145 (MD5) / O objetivo neste estudo foi avaliar e comparar a resistência à fratura de incisivos centrais restaurados usando dois tipos de pinos intra-radiculares: núcleo metálico fundido e pinos de fibra de quartzo, reconstruídos com diferentes tipos de coroas. A hipótese nula testada foi que a resistência a fratura desses corpos de prova não apresentariam diferença quanto ao tipo de pino e tipo de coroa. Sessenta incisivos centrais superiores foram divididos em 6 grupos: G1- núcleo metálico fundido + coroa em cerômero, G2- núcleo metálico fundido + coroa metalo-cerâmica, G3- núcleo metálico fundido + coroa em e-max, G4 – pino de fibra de quartzo e pinos acessórios + coroa em cerômero, G5- pino de fibra de quartzo e pinos acessórios + coroa metalo-cerâmica e G6- pino de fibra de quartzo e pinos acessórios + coroa em e-max. Todos os espécimes foram submetidos à ciclagem mecânica com freqüência de 2 Hz e 500.000 ciclos com carga de 3Kg. Os corpos de prova foram submetidos a teste de compressão em uma máquina universal de ensaios (Emic) com velocidade de carga de 1,0 mm/min até a sua fratura. Os valores de resistência à fratura foram G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. A análise de variância (ANOVA) (p<0,05) mostrou diferença estatisticamente significante para os pinos. Quanto à análise de fratura, os núcleos metálicos fundidos apresentaram o maior número de amostras com fratura desfavoráveis quando comparados os pinos de fibra de quartzo. O conjunto pino de fibra restaurados com coroa metalo cerâmica, apresentou valor de resistência à fratura estatisticamente maior quando comparado aos demais grupos segundo o teste de Tukey (5%), Metalo cerâmica - 64,12±13,69 kgf, difere estatisticamente das demais coroas metal free - 52,59±9,88 kgf e cerômero - 51,20±10,08 kgf que... / The aim of this study was to compare the fracture resistance and failure of maxillary incisors restored using fiber post and metallic post under different types of full-coverage crowns. The null hypothesis tested was that fracture resistance and the failure pattern of these teeth were not affected by the use of fiber post, metallic post and typo of full coverage crown. Sixty maxillary incisors were divided into 6 groups of 10 each. G1- metallic post + metallic ceramic crowns, G2- metallic post + e-max system, G3- metallic post + cerômeros, G4- Fiber post and accessories post + metallic ceramic crowns, G5- Fiber post and accessories post + e-max system and G6- Fiber post and accessories post + cerômeros. The specimens were submitted a mechanical loading at a frequency of 2 Hz for a total of 500.000 cycles. After were taken to the Universal Test Machine for the fracture resistance at 1,0 mm/min speed. The fracture resistance values were G1- 47.44 ± 10.39, G2- 54.74 ±7.76, G3-49.71 ± 8.66, G4- 54.97 ± 8.67, G5-73.50 ± 11.83 e G6- 55.47 ± 10.62. Results show statistically significant differences in relation to the type of the posts (ANOVA) (p<0,05). Fracture analyses about metallic post showed the most unfavorable fracture and fiber post restored with metallic crown showed statistically significant difference in relation to the others groups. Tukey test (5%) showed Metallic-crown - 64,12±13,69 kgf, is statistically difference than the other crowns metal free - 52,59±9,88 kgf and Sinfony crowns - 51,20±10,08 kgf that was not different between itself. The result of this study indicate that the use of fiber posts increase their resistance to fracture and improve the prognosis in case of fracture
26

Estudo comparativo in vitro da resistência ao cisalhamento de discos metálicos de níquel-cromo, com ou sem tratamento de superfície, unidos à dentina bovina com quatro cimentos

Uemura, Eduardo Shigueyuki [UNESP] 21 June 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-06-21Bitstream added on 2015-01-26T13:30:17Z : No. of bitstreams: 1 000127814.pdf: 3655431 bytes, checksum: 12e1609540144e91b6188d471f4f987c (MD5) / O estudo foi realizado com oitenta incisivos inferiores bovinos. Os dentes foram extraídos, limpos, as raízes foram seccionadas, o tecido pulpar coronário foi removido e submetido à congelamento a -18°C, por um tempo máximo de 28 dias. A inclusão foi feita em gesso pedra tipo IV. Após o desgaste do esmalte, a dentina superficial foi preparada numa área de 5mm, sendo que a espessura de dentina remanescente foi padronizada (1 ,7 a 2mm). Os discos de liga de Ni-Cr tinham 3X5mm de diâmetro e todos foram submetidos a um ciclo de queima de cerâmica. Metade dos discos foram jateados com óxido de alumínio de 50µm.enquanto a outra metade não sofreu este tratamento. Após limpeza em ultra•som os discos foram cimentados à dentina com: cimento de fosfato de zinco-S.S.White (controle), cimento de ionômero de vidro modificado por resina (CIVMR) Fuji Plus-Fuji, Cimento Resinoso 3M-3M e cimento resinoso Panavia 21-Kuraray. Os dados, após análise estatística ANOVA e teste de Tukey (p< 0,05), mostraram para as variáveis cimento e tratamento de superfície dos discos metálicos os seguintes valores médios de resistência da união dentina/cimento/metal: cimento resinoso Panavia 21 com jateamento (18,29MPa), sem jateamento (17,87MPa); Cimento Resinoso 3M com jateamento (15,81MPa), sem jateamento (11,40MPa); CIVMR com jateamento (16,57MPa), sem jateamento (16,70MPa); cimento de fosfato de zinco com jateamento (3,35MPa), sem jateamento (0,9BMPa). As médias dos valores de resistências ao cisalhamento permitiram concluir: a) houve diferença estatisticamente significante entre o cimento controle e os cimentos em teste; b) não houve diferença estatisticamente significante entre o cimento resinoso Panavia 21 e o CIVMR, mas ambos foram estatisticamente diferentes do cimento resinoso 3M; c) houve diferença estatisticamente significante entre as médias de resistência dos espécimes jateados / This study was carried out with 80 bovine lower incisors. After extraction and debridement the teeth were cut in two parts (crown and roof), having the pulp tissue removed. Crowns were frozen at -18° C for a maximum period of 28 days and then embedded in type IV stone. Preparations were carried out in superficial dentin (minimum 5mm area) while the remaining dentin thickness was standardized (1.7 to 2mm). 80 Ni-Cr disks (3mm height, 5mm diameter) were submitted to a ceramic firing cycle. Half the disks had a 50µm AL2O3 blast while the other half did not. Cements used were: ZPC -SSW, GICRM Fuji Plus-Fuji; 3M resinous cement - 3M; resinous cement Panavia 21- Kuraray. After ANO VA statistical analysis and Tukey's test (p> 0.05), data showed the following shear bond strength mean values at the interface dentin/cement/Ni-Cr disks: dentin/Panavia 21/ blasted Ni-Cr disks (18,29MPa), dentin/Panavia 21/ non blasted Ni-Cr disks (17, 87MPa); dentin/Fuji Plus/blasted Ni-Cr disks (16,57MPa), dentin/Fuji Plus/non-blasted Ni-Cr disks (16.70MPa); dentin/3M resinous cement/blasted Ni-Cr disks (15.81 MPa), dentin/3M resinous cement/non-blasted Ni-Cr disks (11,40MPa); dentin/ZPC/blasted Ni-Cr disks (3,35 MPa), dentin/ZPC/non-blasted Ni-Cr disks (O,98MPa). Results lead to the conclusions: a) control and tested cements mean shear bond strength values showed a significant statistical difference; b) there was no significant statistical difference between Fuji Plus and Panavia mean shear bond strengths, though both values differed statistically from 3M resinous cement mean shear bond strength; c) blasted and non-blasted specimens mean shear bond strength values showed a statistical significant difference; d) There was no significant statistical difference between resin modified GICRM and Panavia 21 mean shear bond strength values, with or without Ni-Cr disks blasting
27

Protocolos de limpeza de dentina contaminada por diferentes soluções de efeito hemostático

Bernades, Karina de Oliveira 03 December 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências Farmacêuticas, 2014. / Submitted by Larissa Stefane Vieira Rodrigues (larissarodrigues@bce.unb.br) on 2015-02-10T19:21:41Z No. of bitstreams: 1 2014_KarinaDeOliveiraBernades.pdf: 13657967 bytes, checksum: 6c94c964283c8a35a990c7291b2a4ea2 (MD5) / Approved for entry into archive by Ruthléa Nascimento(ruthleanascimento@bce.unb.br) on 2015-02-11T17:46:50Z (GMT) No. of bitstreams: 1 2014_KarinaDeOliveiraBernades.pdf: 13657967 bytes, checksum: 6c94c964283c8a35a990c7291b2a4ea2 (MD5) / Made available in DSpace on 2015-02-11T17:46:50Z (GMT). No. of bitstreams: 1 2014_KarinaDeOliveiraBernades.pdf: 13657967 bytes, checksum: 6c94c964283c8a35a990c7291b2a4ea2 (MD5) / O objetivo deste trabalho foi avaliar a resistência de união ao microcisalhamento (RUMC) do cimento resino autoadesivo RelyX U200 (3M/ESPE) à dentina, em função de diferentes agentes contaminantes e protocolos de limpeza. Cento e cinco incisivos bovinos foram selecionados, limpos e armazenados em solução neutra de timol 0,1%. As superfícies vestibulares dos dentes foram desgastadas em máquina recortadora de gesso, as coroas foram separadas das raízes e incluídas em resina acrílica em tubos de PVC. Lixas de carbeto de silício foram utilizadas para planificação da superfície. Os dentes foram inicialmente divididos aleatoriamente em 5 grupos, quanto ao agente contaminante: C (Controle), V (ViscoStat), VC (ViscoStat Clear), E (Visine), D (Sure). Os 4 grupos contaminados foram então subdivididos em 5, quanto ao protocolo de limpeza: W (jato spray de água por 15s), A (ácido fosfórico 37%C + jato spray de água por 15s (JSA – 15s), E (EDTA por 60 segundos + JSA – 15s.), O (Jateamento com óxido de alumínio por 15s + JSA – 15s), P (profilaxia com pedra pomes por 15s + JSA – 15s). A delimitação da área de adesão foi conseguida com fita adesiva dupla-face. Tubos de amido (0,96 mm de diâmetro e 2 mm de altura) permitiram a confecção dos cilindros de resina, que coincide com a área delimitada. Os testes de resistência ao microcisalhamento foram realizados após 24 horas, em uma máquina de ensaios mecânicos de resistência ao cisalhamento (Bisco Shear Bond Tester) à velocidade de 0,5 mm/min e com célula de carga de 50 kN. A análise do padrão de fratura foi realizada utilizando lupa estereoscópica (SZX9, Olympus). Com caráter ilustrativo, um dente representativo de grupos previamente selecionados foram separados para observação em MEV. Os dados foram submetidos à ANOVA – 2 critérios e teste de Tukey (α=0,05). Os valores de média + desvio padrão para RUMC (MPa) encontrados foram:C (11,15 + 0,52)DEFG, VW (2,06 + 0,51)I, VA (0,98 + 0,39)I, VE (3,71 + 0,66)HI, VO (9,52 + 0,86)FG, VP (16,64 + 0,94)GHI, VCW (3,35 + 1,06)AB, VCA (7,06 + 0,99)BC, VCE (2,85 + 0,90)A, VCO (12,06 + 1,01)CDEF, VCP (10,22 + 0,81)EFG, EW (16,11 + 0,82)ABC, EA (4,34 + 0,70)HI, EE (1,35 + 0,34)I, EO (13,98 + 0,76)ABCDE, DW (12,90 + 1,08)BCDEF, DA (11,98 + 1,11)CDEF, DE (1,72 + 0,50)I, DO (17,78 + 0,95)A, DP (14,42 + 0,55)ABCD. Os contaminantes V e VC demonstraram os piores resultados. O protocolo de limpeza A deveria ser evitado e não utilizado para o contaminante V. O protocolo E não deveria ser utilizado para o material RelyX U200. Os protocolos P e O demonstraram ser eficicientes para todos os contaminantes. Considerando as limitações do presente estudo pode-se concluir que na presença de contaminação com agentes hemostáticos, a utilização de um protocolo de limpeza adequado é de fundamental importância para estabelecer uma resistência de união aceitável do cimento RelyX U200 à dentina. Saber as possíveis interações do agente contaminante com o método de limpeza é essencial para melhor escolha deste. _________________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate the microshear bond strength of self-adhesive cement RelyX U200 (3M/ESPE) to dentin, due to different hemostatic agents and cleasing protocol. One hundred and five bovine incisors were selected, cleaned and stored in neutral solution of 0.1% thymol. The buccal surfaces of the teeth were worn out in a plaster trimmer machine, the crowns were separated from the roots and embedded with acrylic resin in PVC tubes. It was used silicon carbide sandpaper for obtaining flat buccal surfaces. The teeth were ramdomly divided into 5 groups, according to the hemostatic agent: C (Control – no contamination), V (ViscoStat), VC (ViscoStat Clear, E (Visine), D (Sure). The 4 contaminated groups were then subdivided into 5, according the cleasing protocol: W ( water spray for 15s), A (phosphoric acid 37% for 15s + water spray for 15s), E (EDTA for 15s + water spray 15s), O (Aluminum oxide abrasion for 15s + water spray for 15s), P (Pumice prophylaxis for 15s + water spray for 15s). The delimitation of bonding area was achieve with adhesive double-sided tape. Starch tubes (0,96 mm diameter and 2 mm height) allowed manufacturing of cement cylinders, which coincide with delimited areas. The microshear strength tests were performed after 24h, a mechanical testing machine (Bisco Shear Bond Tester), speed 0,5 mm/min and load cell of 50 kN. The analysis of the fracture was performed using a stereomicroscope (SZX9, Olympus). With illustrative, one representative tooth of previously selected groups were observed in scanning electron microscopy. Data were analyzed by two-way ANOVA and Tukey tests (α=0,05). Results for microshear bond strength were: C (11,15 + 0,52)DEFG, VW (2,06 + 0,51)I, VA (0,98 + 0,39)I, VE (3,71 + 0,66)HI, VO (9,52 + 0,86)FG, VP (16,64 + 0,94)GHI, VCW (3,35 + 1,06)AB, VCA (7,06 + 0,99)BC, VCE (2,85 + 0,90)A, VCO (12,06 + 1,01)CDEF, VCP (10,22 + 0,81)EFG, EW (16,11 + 0,82)ABC, EA (4,34 + 0,70)HI, EE (1,35 + 0,34)I, EO (13,98 + 0,76)ABCDE, DW (12,90 + 1,08)BCDEF, DA (11,98 + 1,11)CDEF, DE (1,72 + 0,50)I, DO (17,78 + 0,95)A, DP (14,42 + 0,55)ABCD. Most fractures were type adhesive. The contaminants V and VC showed the worst results. The cleasing protocol A, should be avoid and not used to Fe2(SO4)3 .The protocol E should not be used to the material RelyX U200. The protocols P and O showed be efficient to all types of contaminants. Considering the limitations of this study it is concluded that in the presence of hemostatic agent contamination, the use of an adequated cleasing protocol is totally important to the establishment of an acceptable bond strength of RelyX U200 to dentin. Furthermore the knowledge of the possible interactions between contaminant and cleasing protocol is essential for better choice of this one.
28

Imunolocalização de CSF-1, OPG e RANKL no periodonto relacionado ao esmalte de incisivos de ratos em erupção normal e contida / Immunolocalization of CSF-1, OPG and RANKL in the enamel-related periodontium of rat incisors in normal and immobilized eruption

Neves, Juliana dos Santos, 1982- 18 February 2008 (has links)
Orientador: Pedro Duarte Novaes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T09:21:31Z (GMT). No. of bitstreams: 1 Neves_JulianadosSantos_M.pdf: 17773747 bytes, checksum: 861f7b8b208320f769d2c3c3c20302c5 (MD5) Previous issue date: 2008 / Resumo: Nos incisivos de ratos a face do alvéolo relacionada ao esmalte é continuamente reabsorvida do lado interno e neoformada no lado externo. Estudo realizado em nosso laboratório mostrou que em incisivos de ratos contidos por um período de 18 dias, há uma substituição de reabsorção óssea na face do alvéolo relacionada ao esmalte por neoformação óssea, onde osteoclastos foram substituídos por osteoblastos. CSF-1 e RANKL estimulam a proliferação e diferenciação de osteoclastos enquanto a OPG possui potente atividade inibitória da osteoclastogênese. O objetivo deste estudo foi analisar a distribuição e a intensidade do CSF-1, RANKL e OPG nos tecidos periodontais relacionados ao esmalte (PRE), de incisivos inferiores de ratos em erupção normal e após período de 18 dias de contenção, utilizando método imunohistoquímico e associando a análise quantitativa de osteoclastos. Quinze ratos Wistar machos tiveram seu incisivo inferior esquerdo imobilizado por meio de um fio de aço preso ao 1° molar inferior esquerdo por 18 dias. Quinze ratos com o incisivo esquerdo em erupção normal foram utilizados como controle. A taxa de erupção foi medida por meio de uma marca feita na face labial da coroa. No 18º dia de experimento os animais foram sacrificados e a região da crista alveolar do incisivo foi separada. Os incisivos de 12 ratos (6 controles e 6 contidos) foram fixadas e processadas para inclusão em Paraplast e reação imunohistoquímica foi realizada utilizando anticorpos primários anti-CSF-1, OPG e RANKL. A intensidade de marcação do folículo dentário foi quantificada através de medida da densidade óptica, utilizando o ¿software¿ de análise de imagens Leica QWin (Leica imaging systems, Cambridge, UK ) e ambos os grupos foram comparados pelo test t não-pareado. Para verificar a atividade osteoclástica, os incisivos de 18 ratos (9 controles e 9 contidos) foram fixadas e processadas para inclusão em Historesina e foram realizadas a evidenciação da fosfatase ácida resistente ao tartarato (TRAP) e a contagem de osteoclastos TRAP positivos presentes em toda a extensão do osso alveolar que circunda o esmalte. A contenção com fio de aço mostrou-se eficiente em imobilizar o incisivo. A diferença na quantidade de osteoclastos entre os grupos foi significante (p<0.001), sendo que no incisivo normofuncional a quantidade destes foi aproximadamente três vezes maior que no contido. Para o CSF-1 e OPG não houve, no folículo dentário, diferença estatisticamente significante na intensidade de marcação entre os grupos (p>0.05). Para RANKL o grupo contido apresentou-se com intensidade de marcação menor do que o normofuncional (p<0.01). As moléculas estudadas estavam presentes no PRE, da região da crista de incisivos inferiores de ratos, em erupção normal e contida, sendo que na condição contida houve uma diminuição na intensidade de RANKL e da quantidade de osteoclastos. Diante desta observação, podemos concluir que alterações nos tecidos que compõem o PRE no incisivo contido, modificam o balanço na relação RANKL/OPG alterando o metabolismo das células que participam da remodelação óssea / Abstract: In the rat incisors the face of the socket related to the enamel is resorpted continually on the inner side and formed on the outer side. A study accomplished at our laboratory showed that in rat incisors immobilized by a period of 18 days, there is a replacement of bone resorption in the face of the socket related to the enamel by bone formation, where osteoclasts were substituted by osteoblasts. CSF-1 and RANKL stimulate the proliferation and osteoclast differentiation while OPG has a potent osteoclastogenesis inhibitory activity. The aim of this study was to analyze the distribution and intensity of CSF-1, RANKL and OPG in periodontal tissues related to the enamel (PRE) of rat lower incisors, in normal eruption and after the period of 18 days of containment, using immunohistochemical technique and associating the quantitative analysis of osteoclasts. Fifteen male Wistar rats had their left lower incisor immobilized by means of a steel wire attached to the first left lower molar for 18 days. Fifteen rats with the left lower incisor in normal eruption were used as control. The eruption rate was measured using landmarks in the labial face of the crown. The animals were killed on day 18th and the region of the alveolar crest of the incisor was split. The incisors of 12 rats (6 control and 6 immobilized) were fixed and processed for embedding in Paraplast and immunohistochemical assay was accomplished using primary antibodies anti-CSF-1, OPG and RANKL. The immunostaining of the dental follicle was quantified by measure of the optical density, using the image analysis software Leica QWin (Leica imaging systems, Cambridge, UK) and both groups were compared by test t. To verify osteoclast activity, the incisors of 18 rats (9 control and 9 immobilized) were fixed and processed for embedding in Historesin and to make the tartrate resistant acid phosphatase (TRAP) evident. Osteoclasts TRAP positive in the whole length of the alveolar bone surrounding the enamel were counted. The incisor immobilization with steel wire was efficient. The difference in the number of osteoclasts between both rat groups was significant (p<0.001). In the normal incisor, the number of osteoclasts was threefold greater than in the immobilized tooth. In the dental follicle, there wasn't significant difference in the immunostaining intensity for CSF-1 and OPG between the groups (p>0.05). The immobilized incisor group showed immunostained intensity smaller than the normal incisor group (p <0.01). The studied molecules were present in PRE, in the region of the alveolar crest of rat lower incisor, in normal and immobilized eruption. There was a decrease in the intensity of RANKL immunostaining and in the number of osteoclasts in the immobilized condition. Hence, we concluded that changes in tissues of PRE, in the immobilized incisor, modify the RANKL/OPG ratio altering the metabolism of cells that participate in the bone remodeling / Mestrado / Histologia e Embriologia / Mestre em Biologia Buco-Dental
29

Efeito de doses cronicas oscilantes de fluoreto no desenvolvimento de fluorose dental em ratos / Effect of chronic oscillating fluoride doses on dental fluorosis development in rats

Catani, Danilo Bonadia 02 November 2010 (has links)
Orientadores: Livia Maria Andalo Tenuta, Jaime Aparecido Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T10:27:51Z (GMT). No. of bitstreams: 1 Catani_DaniloBonadia_D.pdf: 3182260 bytes, checksum: 1cbcbeff9370ac4ee3fd869799aca3fe (MD5) Previous issue date: 2010 / Resumo: O efeito do fluoreto (F) no desenvolvimento de fluorose dental em animais expostos a doses crônicas constantes é bem conhecido, mas não há informações sobre o efeito de doses crônicas oscilantes, o que foi estudado neste trabalho. Além disso, não há estudos comparando diferentes métodos de quantificação de defeito de esmalte induzido pelo F, o que também foi avaliado. O estudo foi composto por três trabalhos. Foram utilizadas ratas fêmeas da linhagem Wistar com idade de 35 dias, as quais receberam água e ração ad libitum durante um período suficiente para permitir o completo crescimento dos incisivos (70 a 78 dias). Após, os animais foram anestesiados, o sangue foi coletado e os incisivos, mandíbulas e fêmures, removidos após a morte por hemorragia. A concentração de F no plasma, nos incisivos e nos ossos foi determinada usando um eletrodo íon específico. No primeiro estudo, 20 ratas foram divididas casualmente em 5 grupos: quatro grupos receberam água com concentrações constantes de F (0; 12,5; 25 ou 37,5 µg F/mL) e o outro grupo recebeu água contendo 12,5 e 37,5 µg F/mL, alternados a cada 72 h (média de exposição igual a 25 µg F/mL). Não foi observada diferença nas variáveis metabólicas e na gravidade de fluorose dental entre o grupo que recebeu doses oscilantes e o grupo que recebeu dose correspondente à média das oscilações (p > 0,05). No segundo estudo, foram utilizadas 58 ratas, as quais foram divididas casualmente em grupos expostos a diferentes concentrações de F na água (0 a 75 µg F/mL) constantes ou alternantes (12,5 e 75 µg F/mL) por períodos assimétricos (2 ou 8 dias). A exposição a doses oscilantes de F resultou em concentrações de F no sangue e ossos e fluorose dental semelhantes às observadas nos animais expostos à média das oscilações em função do tempo utilizado. No terceiro estudo, foram utilizadas 35 ratas, divididas casualmente em 7 grupos de 5 animais cada, que receberam água em concentrações crescentes de F: 0; 12,5; 25; 50; 62,5; 75 ou 100 µg F/mL. Os incisivos foram utilizados para avaliar 5 métodos de quantificação de fluorose: radiomicrografia, microdureza, microscopia de luz polarizada, análise de fluorescência e análise da imagem da superfície do esmalte segundo o padrão de bandas claras e escuras presentes na superfície do esmalte fluorótico de ratos. Radiomicrografia, microdureza e microscopia de luz polarizada só foram capazes de detectar fluorose sob altas concentrações de F (= 50 µg/mL) e a análise de fluorescência não permitiu diferenciação entre os grupos. A análise da imagem da superfície do esmalte foi satisfatória para quantificar fluorose, mesmo nas menores concentrações de F utilizadas nesse estudo, e foi utilizada para quantificar fluorose nos estudo subsequentes. Os resultados dos estudos sugerem que o efeito biológico da exposição crônica a doses oscilantes de F reflete a média do efeito das doses oscilantes de acordo com o tempo de exposição. A análise da imagem da superfície do esmalte se mostrou um método adequado para quantificar fluorose em incisivos de ratos. / Abstract: The effect of fluoride (F) on the development of dental fluorosis in animals chronically exposed to constant F doses is well known, but there is no information about the effect of chronic oscillating doses, and this was evaluated in the present study. Moreover, there are no studies comparing different methods of quantification of enamel defects induced by F, which was also evaluated. The study comprised of three experiments. Wistar female rats, aged 35 days, received water and food ad libitum during enough time to allow the full growth of the incisors (70 to 78 days). After, the animals were anesthetized, blood was collected and femurs, mandible bones and incisors were removed after their death by bleeding. F concentration in the blood plasma, bones and teeth was determined using ion-specific electrode. In the first study, 20 rats were randomly divided into 5 groups: four groups received water with constant F concentration at 0, 12.5, 25 or 37.5 µg F/mL and the other group received water containing 12.5 and 37.5 µg F/mL, which were alternated at each 72 h (mean exposure equals to 25 µg F/mL). No difference in metabolic variables and in severity of dental fluorosis between the group which received oscillating doses and the group receiving 25 µg F/mL was observed (p > 0.05). In the second study, 58 rats were randomly divided into groups which were chronically exposed to different F concentration in the water (0 to 75 µg F/mL), constant or oscillating (12.5 and 75 µg F/mL) for different periods of length (2 or 8 days). Exposure to oscillating F doses resulted in F concentrations in blood plasma and bones and enamel fluorosis similar to those observed in groups receiving F concentrations equal to the means of the oscillating range, according to the period length. In the third study, 35 rats were randomly divided into 7 groups of 5 animals, which received water at increasing F concentrations: 0, 12.5, 25, 50, 62.5, 75 or 100 µg F/mL. Incisors were used to assess fluorosis using five quantification methods: transverse microradiography, cross-sectional microhardness, polarized bright microscopy, quantitative light-induced fluorescence and image analysis of the enamel surface based on the pattern of white and dark bands present on rat fluorotic enamel. Transverse microradiography, cross sectional microhardness and bright field microscopy were only able to detect the fluorotic defect in the rat incisor when high F concentrations (= 50 µg F/mL) were used and quantitative ightinduced fluorescence analysis did not allow the differentiation among the groups. The image analysis method of the enamel surface was satisfactory to quantify dental fluorosis, even at low F concentrations, and was used to evaluate fluorosis in the subsequent studies. The present study suggests that the biological effect of F when an animal is exposed chronically to oscillating F doses may reflect the effect of the mean of the oscillating doses, according to exposure length. The image analysis of the enamel surface was a suitable method to quantify enamel fluorosis in rat incisors. / Doutorado / Saude Coletiva / Doutor em Odontologia
30

Efeitos do chumbo na formação do esmalte fluorótico em ratos / Effects of lead in the formation of fluorotic enamel in rats

Giselle de Angelo Souza Leite 18 September 2009 (has links)
A co-exposição ao chumbo e ao flúor pode alterar o grau de fluorose dental, uma vez que ambos se depositam nos tecidos dentais. Ratos Wistar foram separados em 4 grupos: controle e 3 grupos que recebiam água contendo 100ppm de flúor (F), 30ppm de chumbo (Pb), ou 100ppm de F mais 30ppm de Pb desde a gestação. Análise do esmalte e determinação das dosagens de F no esmalte, dentina e osso foram realizadas nos animais com 81 dias. Defeitos nos incisivos dos ratos foram usados como escores em um índice que discriminou lesões na superfície como bandas, ilhas e cavidades. Não houve diferenças nas concentrações de F nos tecidos calcificados entre os grupos F e F+Pb. Os grupos controle e chumbo apresentaram esmalte normal. O grupo F+Pb apresentou defeitos de esmalte mais severos quando comparados com o grupo F (P<0.001). Este estudo mostrou que o Pb exacerbou a fluorose dental em roedores, sugerindo que a co-exposição ao PB pode explicar as diferenças na prevalência de fluorose. / Co-exposure to lead and fluoride may alter the degree of dental fluorosis, since both accumulate in calcified tissues. Wistar rats were allocated in four groups: control, and 3 groups that received water containing 100 ppm of fluoride (F), 30 ppm of lead (Pb), or 100 ppm of F and 30 ppm of Pb (F+Pb) since gestational age. Enamel analysis and F determinations in enamel, dentine, and bone were performed in 81-day-old animals. Incisor defects were scored using an index that discriminated surface lesions as bands, islets, and pits. There were no differences in the F concentration in calcified tissues between the F and F+Pb groups. The control and the Pb groups presented normal enamel. The F+Pb group presented more severe enamel defects compared with the F group (P<0.001). This study shows that Pb exacerbates dental fluorosis in rodents, suggesting that co-exposure to Pb may explain differences in fluorosis prevalence.

Page generated in 0.0459 seconds