• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 64
  • 48
  • Tagged with
  • 195
  • 195
  • 145
  • 132
  • 128
  • 128
  • 54
  • 47
  • 47
  • 47
  • 46
  • 40
  • 30
  • 28
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Validation in-vivo des techniques d’élastographie ultrasonore, invasive et non-invasive, à l’aide d’un modèle porcin

Valiallah, Hasti 10 1900 (has links)
Il est maintenant admis que la composition de la plaque athérosclérotique est un déterminant majeur de sa vulnérabilité à se rompre. Vu que la composition de la plaque affecte ses propriétés mécaniques, l'évaluation locale des propriétés mécaniques de la plaque d'athérome peut nous informer sur sa vulnérabilité. L'objectif est de comparer les techniques d’élastographie ultrasonores endovasculaire (EVE) et non-invasive (NIVE) en fonction de leur potentiel à identifier les composantes calcifiées et lipidiques de la plaque. Les acquisitions intravasculaire et extravasculaire ont été effectuées sur les artères carotidiennes de neuf porcs hypercholestérolémiques à l’aide d’un cathéter de 20 MHz et d'une sonde linéaire de 7.5 MHz, respectivement. Les valeurs de déformation radiale et axiale, rapportés par EVE et NIVE, ont été corrélées avec le pourcentage des zones histologiques calcifiées et lipidiques pour cinq plaques. Nos résultats démontrent une bonne corrélation positive entre les déformations et les composantes calcifiées (r2 = 0.82, P = 0.034 valeur par EVE et r2 = 0.80, P = 0.041 valeur par NIVE). Une forte corrélation entre les déformations axiales et les contenus lipidiques par NIVE (r2 = 0.92, P-value = 0.010) a été obtenue. En conclusion, NIVE et EVE sont des techniques potentielles pour identifier les composants de la plaque et aider les médecins à diagnostiquer précocement les plaques vulnérables. / It is now widely accepted that plaque composition is a major determinant of plaque’s vulnerability to rupture. Since composition of the plaque affects its mechanical properties, the local assessment of mechanical properties of atherosclerotic plaque may inform us about plaque’s vulnerability. The objective is to compare ultrasonic endovascular elastography (EVE) versus non-invasive vascular elastography (NIVE) according to their potential to identify plaque contents. Intravascular and extravascular acquisitions were performed on carotid arteries of nine hypercholesterolemic minipigs with a 20 MHz catheter and a 7.5 MHz standard probe, respectively. Radial and axial strain values, reported by EVE and NIVE respectively, were correlated with histological area of lipid and calcium for five plaques. Our results demonstrate a good positive correlation between strains and calcified contents (r2=0.82, P-value=0.034 by EVE and r2=0.80, P-value= 0.041 by NIVE). Additionally, there is a strong correlation between axial strains and lipid contents by NIVE (r2=0.92, P-value= 0.010). In conclusion, NIVE and EVE are the potential techniques to identify plaque components and to help physicians to early diagnose the vulnerable plaques.
132

A brain-computer interface for navigation in virtual reality

Alchalabi, Bilal 04 1900 (has links)
L'interface cerveau-ordinateur (ICO) décode les signaux électriques du cerveau requise par l’électroencéphalographie et transforme ces signaux en commande pour contrôler un appareil ou un logiciel. Un nombre limité de tâches mentales ont été détectés et classifier par différents groupes de recherche. D’autres types de contrôle, par exemple l’exécution d'un mouvement du pied, réel ou imaginaire, peut modifier les ondes cérébrales du cortex moteur. Nous avons utilisé un ICO pour déterminer si nous pouvions faire une classification entre la navigation de type marche avant et arrière, en temps réel et en temps différé, en utilisant différentes méthodes. Dix personnes en bonne santé ont participé à l’expérience sur les ICO dans un tunnel virtuel. L’expérience fut a était divisé en deux séances (48 min chaque). Chaque séance comprenait 320 essais. On a demandé au sujets d’imaginer un déplacement avant ou arrière dans le tunnel virtuel de façon aléatoire d’après une commande écrite sur l'écran. Les essais ont été menés avec feedback. Trois électrodes ont été montées sur le scalp, vis-à-vis du cortex moteur. Durant la 1re séance, la classification des deux taches (navigation avant et arrière) a été réalisée par les méthodes de puissance de bande, de représentation temporel-fréquence, des modèles autorégressifs et des rapports d’asymétrie du rythme β avec classificateurs d’analyse discriminante linéaire et SVM. Les seuils ont été calculés en temps différé pour former des signaux de contrôle qui ont été utilisés en temps réel durant la 2e séance afin d’initier, par les ondes cérébrales de l'utilisateur, le déplacement du tunnel virtuel dans le sens demandé. Après 96 min d'entrainement, la méthode « online biofeedback » de la puissance de bande a atteint une précision de classification moyenne de 76 %, et la classification en temps différé avec les rapports d’asymétrie et puissance de bande, a atteint une précision de classification d’environ 80 %. / A Brain-Computer Interface (BCI) decodes the brain signals representing a desire to do something, and transforms those signals into a control command. However, only a limited number of mental tasks have been previously detected and classified. Performing a real or imaginary navigation movement can similarly change the brainwaves over the motor cortex. We used an ERS-BCI to see if we can classify between movements in forward and backward direction offline and then online using different methods. Ten healthy people participated in BCI experiments comprised two-sessions (48 min each) in a virtual environment tunnel. Each session consisted of 320 trials where subjects were asked to imagine themselves moving in the tunnel in a forward or backward motion after a randomly presented (forward versus backward) command on the screen. Three EEG electrodes were mounted bilaterally on the scalp over the motor cortex. Trials were conducted with feedback. In session 1, Band Power method, Time-frequency representation, Autoregressive models and asymmetry ratio were used in the β rhythm range with a Linear-Discriminant-analysis classifier and a Support Vector Machine classifier to discriminate between the two mental tasks. Thresholds for both tasks were computed offline and then used to form control signals that were used online in session 2 to trigger the virtual tunnel to move in the direction requested by the user's brain signals. After 96 min of training, the online band-power biofeedback training achieved an average classification precision of 76 %, whereas the offline classification with asymmetrical ratio and band-power achieved an average classification precision of 80%.
133

Segmentation d’images intravasculaires ultrasonores

Roy Cardinal, Marie-Hélène 10 1900 (has links)
L'imagerie intravasculaire ultrasonore (IVUS) est une technologie médicale par cathéter qui produit des images de coupe des vaisseaux sanguins. Elle permet de quantifier et d'étudier la morphologie de plaques d'athérosclérose en plus de visualiser la structure des vaisseaux sanguins (lumière, intima, plaque, média et adventice) en trois dimensions. Depuis quelques années, cette méthode d'imagerie est devenue un outil de choix en recherche aussi bien qu'en clinique pour l'étude de la maladie athérosclérotique. L'imagerie IVUS est par contre affectée par des artéfacts associés aux caractéristiques des capteurs ultrasonores, par la présence de cônes d'ombre causés par les calcifications ou des artères collatérales, par des plaques dont le rendu est hétérogène ou par le chatoiement ultrasonore (speckle) sanguin. L'analyse automatisée de séquences IVUS de grande taille représente donc un défi important. Une méthode de segmentation en trois dimensions (3D) basée sur l'algorithme du fast-marching à interfaces multiples est présentée. La segmentation utilise des attributs des régions et contours des images IVUS. En effet, une nouvelle fonction de vitesse de propagation des interfaces combinant les fonctions de densité de probabilité des tons de gris des composants de la paroi vasculaire et le gradient des intensités est proposée. La segmentation est grandement automatisée puisque la lumière du vaisseau est détectée de façon entièrement automatique. Dans une procédure d'initialisation originale, un minimum d'interactions est nécessaire lorsque les contours initiaux de la paroi externe du vaisseau calculés automatiquement sont proposés à l'utilisateur pour acceptation ou correction sur un nombre limité d'images de coupe longitudinale. La segmentation a été validée à l'aide de séquences IVUS in vivo provenant d'artères fémorales provenant de différents sous-groupes d'acquisitions, c'est-à-dire pré-angioplastie par ballon, post-intervention et à un examen de contrôle 1 an suivant l'intervention. Les résultats ont été comparés avec des contours étalons tracés manuellement par différents experts en analyse d'images IVUS. Les contours de la lumière et de la paroi externe du vaisseau détectés selon la méthode du fast-marching sont en accord avec les tracés manuels des experts puisque les mesures d'aire sont similaires et les différences point-à-point entre les contours sont faibles. De plus, la segmentation par fast-marching 3D s'est effectuée en un temps grandement réduit comparativement à l'analyse manuelle. Il s'agit de la première étude rapportée dans la littérature qui évalue la performance de la segmentation sur différents types d'acquisition IVUS. En conclusion, la segmentation par fast-marching combinant les informations des distributions de tons de gris et du gradient des intensités des images est précise et efficace pour l'analyse de séquences IVUS de grandes tailles. Un outil de segmentation robuste pourrait devenir largement répandu pour la tâche ardue et fastidieuse qu'est l'analyse de ce type d'images. / Intravascular ultrasound (IVUS) is a catheter based medical imaging technique that produces cross-sectional images of blood vessels. These images provide quantitative assessment of the vascular wall, information about the nature of atherosclerotic lesions as well as the plaque shape and size. Over the past few years, this medical imaging modality has become a useful tool in research and clinical applications, particularly in atherosclerotic disease studies. However, IVUS imaging is subject to catheter ring-down artifacts, missing vessel parts due to calcification shadowing or side-branches, heterogeneously looking plaques and ultrasonic speckle from blood. The automated analysis of large IVUS data sets thus represents an important challenge. A three-dimensional segmentation algorithm based on the multiple interface fast-marching method is presented. The segmentation is based on region and contour features of the IVUS images: a new speed fonction for the interface propagation that combines the probability density functions (PDFs) of the vessel wall components and the intensity gradients is proposed. The segmentation is highly automated with the detection of the lumen boundary that is fully automatic. Minimal interactions are necessary with a novel initialization procedure since initial contours of the external vessel wall border are also computed automatically on a limited number of longitudinal images and then proposed to the user for acceptance or correction. The segmentation method was validated with in-vivo IVUS data sets acquired from femoral arteries. This database contained 3 subgroups: pullbacks acquired before balloon angioplasty, after the intervention and at a 1 year follow-up examination. Results were compared with validation contours that were manually traced by different experts in IVUS image analysis. The lumen and external wall boundaries detected with the fast-marching method are in agreement with the experts' manually traced contours with similarly found area measurements and small point-to-point contour differences. In addition, the 3D fast-marching segmentation method dramatically reduced the analysis time compared to manual tracing. Such a valdiation study, with comparison between pre- and post-intervention data, has never been reported in the IVUS segmentation literature. In conclusion, the fast-marching method combining the information on the gray level distributions and intensity gradients of the images is precise and efficient to analyze large IVUS sequences. It is hoped that the fast-marching method will become a widely used tool for the fastidious and difficult task of IVUS image processing.
134

Anatomo-functional magnetic resonance imaging of the spinal cord and its application to the characterization of spinal lesions in cats

Cohen-Adad, Julien 11 1900 (has links)
Les lésions de la moelle épinière ont un impact significatif sur la qualité de la vie car elles peuvent induire des déficits moteurs (paralysie) et sensoriels. Ces déficits évoluent dans le temps à mesure que le système nerveux central se réorganise, en impliquant des mécanismes physiologiques et neurochimiques encore mal connus. L'ampleur de ces déficits ainsi que le processus de réhabilitation dépendent fortement des voies anatomiques qui ont été altérées dans la moelle épinière. Il est donc crucial de pouvoir attester l'intégrité de la matière blanche après une lésion spinale et évaluer quantitativement l'état fonctionnel des neurones spinaux. Un grand intérêt de l'imagerie par résonance magnétique (IRM) est qu'elle permet d'imager de façon non invasive les propriétés fonctionnelles et anatomiques du système nerveux central. Le premier objectif de ce projet de thèse a été de développer l'IRM de diffusion afin d'évaluer l'intégrité des axones de la matière blanche après une lésion médullaire. Le deuxième objectif a été d'évaluer dans quelle mesure l'IRM fonctionnelle permet de mesurer l'activité des neurones de la moelle épinière. Bien que largement appliquées au cerveau, l'IRM de diffusion et l'IRM fonctionnelle de la moelle épinière sont plus problématiques. Les difficultés associées à l'IRM de la moelle épinière relèvent de sa fine géométrie (environ 1 cm de diamètre chez l'humain), de la présence de mouvements d'origine physiologique (cardiaques et respiratoires) et de la présence d'artefacts de susceptibilité magnétique induits par les inhomogénéités de champ, notamment au niveau des disques intervertébraux et des poumons. L'objectif principal de cette thèse a donc été de développer des méthodes permettant de contourner ces difficultés. Ce développement a notamment reposé sur l'optimisation des paramètres d'acquisition d'images anatomiques, d'images pondérées en diffusion et de données fonctionnelles chez le chat et chez l'humain sur un IRM à 3 Tesla. En outre, diverses stratégies ont été étudiées afin de corriger les distorsions d'images induites par les artefacts de susceptibilité magnétique, et une étude a été menée sur la sensibilité et la spécificité de l'IRM fonctionnelle de la moelle épinière. Les résultats de ces études démontrent la faisabilité d'acquérir des images pondérées en diffusion de haute qualité, et d'évaluer l'intégrité de voies spinales spécifiques après lésion complète et partielle. De plus, l'activité des neurones spinaux a pu être détectée par IRM fonctionnelle chez des chats anesthésiés. Bien qu'encourageants, ces résultats mettent en lumière la nécessité de développer davantage ces nouvelles techniques. L'existence d'un outil de neuroimagerie fiable et robuste, capable de confirmer les paramètres cliniques, permettrait d'améliorer le diagnostic et le pronostic chez les patients atteints de lésions médullaires. Un des enjeux majeurs serait de suivre et de valider l'effet de diverses stratégies thérapeutiques. De telles outils représentent un espoir immense pour nombre de personnes souffrant de traumatismes et de maladies neurodégénératives telles que les lésions de la moelle épinière, les tumeurs spinales, la sclérose en plaques et la sclérose latérale amyotrophique. / Spinal cord injury has a significant impact on quality of life since it can lead to motor (paralysis) and sensory deficits. These deficits evolve in time as reorganisation of the central nervous system occurs, involving physiological and neurochemical mechanisms that are still not fully understood. Given that both the severity of the deficit and the successful rehabilitation process depend on the anatomical pathways that have been altered in the spinal cord, it may be of great interest to assess white matter integrity after a spinal lesion and to evaluate quantitatively the functional state of spinal neurons. The great potential of magnetic resonance imaging (MRI) lies in its ability to investigate both anatomical and functional properties of the central nervous system non invasively. To address the problem of spinal cord injury, this project aimed to evaluate the benefits of diffusion-weighted MRI to assess the integrity of white matter axons that remain after spinal cord injury. The second objective was to evaluate to what extent functional MRI can measure the activity of neurons in the spinal cord. Although widely applied to the brain, diffusion-weighted MRI and functional MRI of the spinal cord are not straightforward. Various issues arise from the small cross-section width of the cord, the presence of cardiac and respiratory motions, and from magnetic field inhomogeneities in the spinal region. The main purpose of the present thesis was therefore to develop methodologies to circumvent these issues. This development notably focused on the optimization of acquisition parameters to image anatomical, diffusion-weighted and functional data in cats and humans at 3T using standard coils and pulse sequences. Moreover, various strategies to correct for susceptibility-induced distortions were investigated and the sensitivity and specificity in spinal cord functional MRI was studied. As a result, acquisition of high spatial and angular diffusion-weighted images and evaluation of the integrity of specific spinal pathways following spinal cord injury was achieved. Moreover, functional activations in the spinal cord of anaesthetized cats was detected. Although encouraging, these results highlight the need for further technical and methodological development in the near-future. Being able to develop a reliable neuroimaging tool for confirming clinical parameters would improve diagnostic and prognosis. It would also enable to monitor the effect of various therapeutic strategies. This would certainly bring hope to a large number of people suffering from trauma and neurodegenerative diseases such as spinal cord injury, tumours, multiple sclerosis and amyotrophic lateral sclerosis.
135

Étude du comportement électromécanique du ventricule gauche canin sous différents modes de stimulation

Vo Thang, Thanh-Thuy 02 1900 (has links)
La thérapie de resynchronisation cardiaque (CRT) est un traitement qui diminue la mortalité et améliore la qualité de vie des patients atteints d’insuffisance cardiaque et présentant un dyssynchronisme de la contraction ventriculaire gauche. Malgré le succès de cette thérapie, plus de 30% des patients ne présentent pas l’amélioration désirée. Plusieurs études portant sur le synchronisme électrique ou mécanique de la contraction ont été effectuées mais peu d’entres elles se sont attardées sur le couplage électromécanique à l'échelle macroscopique. Ce projet a comme objectif d’observer le comportement électromécanique des ventricules canins en présence d’un resynchronisateur cardiaque. Un logiciel a été développé pour permettre l’analyse des informations provenant de la cartographie endocardique sans contact et de la ventriculographie isotopique tomographique chez 12 sujets canins insuffisants. Pour observer la réponse mécanique suite à l’activation électrique, nous avons premièrement recalé les surfaces issues des 2 modalités. Ensuite, nous avons défini les limites du cycle cardiaque, analysé les signaux électriques et les courbes de déplacement de la paroi endocardique. Le début de la contraction est défini par un déplacement radial de 10% vers le centre du ventricule. Les résultats démontrent que la durée d’activation du ventricule gauche et la largeur du QRS augmentent en présence d’une stimulation externe et que les délais électromécaniques sont indépendants dans les modes de stimulation étudiés (sinusal, LVbasal, RVapex ou BIV) avec une moyenne de 84,56±7,19 ms. Finalement, nous avons noté que la stimulation basolatérale procure une fonction cardiaque optimale malgré une durée prolongée du QRS. / Cardiac Resynchronization Therapy (CRT) is known to decrease mortality rate and improve the quality of life for patients suffering from heart failure with left ventricular contraction dyssynchrony. However, it has been shown that 30% of patients do not respond to this therapy. Many studies have investigated the electrical or mechanical synchronism of contraction but few have studied the activation contraction coupling on a macroscopic level. The objective of this study is to observe the left ventricle’s electromechanical behaviour under biventricular stimulation. A software has been developed to analyse the data coming from non-contact mapping and blood pool SPECT for 12 dogs with heart failure. In order to observe the mechanical response following an electrical activation, we have registered 3D surfaces generated by the 2 modalities. Afterward, we defined the cardiac cycle limits, and we analyzed electrical signals as well as endocardial wall displacement curves where the onset of contraction was defined as a 10% inward radial displacement. Results show that both duration of left ventricular activation and QRS increase with pacing and that electromechanical delays are independent of stimulation mode (mean value 84,56 ± 7,19 ms). Finally, we observed that basolateral stimulation shows the best improvement for left ventricular function while presenting a long QRS duration.
136

Influence de l’agrégation érythrocytaire sur la migration axiale de microparticules simulant des plaquettes sanguines

Guilbert, Cyrille 06 1900 (has links)
Lors du phénomène d’hémostase primaire ou de thrombose vasculaire, les plaquettes sanguines doivent adhérer aux parois afin de remplir leur fonction réparatrice ou pathologique. Pour ce faire, certains facteurs rhéologiques et hémodynamiques tels que l’hématocrite, le taux de cisaillement local et les contraintes de cisaillement pariétal, entrent en jeu afin d’exclure les plaquettes sanguines de l’écoulement principal et de les transporter vers le site endommagé ou enflammé. Cette exclusion pourrait aussi être influencée par l’agrégation de globules rouges qui est un phénomène naturel présent dans tout le système cardiovasculaire selon les conditions d’écoulement. La dérive de ces agrégats de globules rouges vers le centre des vaisseaux provoque la formation de réseaux d’agrégats dont la taille et la complexité varient en fonction de l’hématocrite et des conditions de cisaillement présentes. Il en résulte un écoulement bi-phasique avec un écoulement central composé d’agrégats de globules rouges avoisinés par une région moins dense en particules où l’on peut trouver des globules rouges singuliers, des petits rouleaux de globules rouges et une importante concentration en plaquettes et globules blancs. De ce fait, il est raisonnable de penser que plus la taille des agrégats qui occupent le centre du vaisseau augmente, plus il y aura de plaquettes expulsées vers les parois vasculaires. L'objectif du projet est de quantifier, in vitro, la migration des plaquettes sanguines en fonction du niveau d’agrégation érythrocytaire présent, en faisant varier l’hématocrite, le taux de cisaillement et en promouvant l’agrégation par l’ajout d’agents tels que le dextran à poids moléculaire élevé. Cependant, le comportement non Newtonien du sang dans un écoulement tubulaire peut être vu comme un facteur confondant à cause de son impact sur l’organisation spatiale des agrégats de globules rouges. De ce fait, les études ont été réalisées dans un appareil permettant de moduler, de façon homogène, la taille et la structure de ces agrégats et de quantifier ainsi leur effet sur la migration axiale des plaquettes. Du sang de porc anti coagulé a été ajusté à différents taux d’hématocrite et insérer dans un appareil à écoulement de Couette, à température ambiante. Les plaquettes sanguines, difficilement isolables in vitro sans en activer certains ligands membranaires, ont été remplacées par des fantômes en polystyrène ayant un revêtement de biotine. La quantification de la migration de ces fantômes de plaquettes a été réalisée grâce à l’utilisation de membranes biologiques fixées sur les parois internes de l’entrefer du rhéomètre de Couette. Ces membranes ont un revêtement de streptavidine assurant une très forte affinité d’adhésion avec les microparticules biotynilées. À 40% d’hématocrite, à un cisaillement de 2 s-1, 566 ± 53 microparticules ont été comptées pour un protocole préétabli avec du sang non agrégeant, comparativement à 1077 ± 229 pour du sang normal et 1568 ± 131 pour du sang hyper agrégeant. Les résultats obtenus suggèrent une nette participation de l’agrégation érythrocytaire sur le transport des fantômes de plaquettes puisque l’adhésion de ces derniers à la paroi du rhéomètre de Couette augmente de façon quasi exponentielle selon le niveau d’agrégation présent. / During the primary hemostatis or thrombosis phenomenon, the human blood platelets must adhere to the vascular wall in order for them to perform their repairing or pathological function. To do so, certain rheological and hemodynamic factors such as the hematocrit, local shear rate and the wall shear stress, must come into play to exclude blood platelets from the main blood stream and transport them to the vicinity of the damaged or inflamed site. This exclusion could also be influenced by red blood cell aggregation which is a natural process present throughout the entire cardiovascular system under certain flow conditions. The displacement of these rouleaux of red blood cells towards the centre of the vessel induces the formation of 3D networks of aggregates whose size and complexity vary as a function of the hematocrit and the shearing conditions present. It results in a two phase flow with an inner core composed of red blood cell aggregates surrounded by single red blood cells or small aggregates and large numbers of white blood cells and platelets. It is therefore reasonable to believe that the larger the inner core becomes, the more platelets will be expulsed towards the vascular wall. The objective of the study was to quantify, in vitro, the lateral migration of blood platelets as a function of the level of red blood cell aggregation present, by changing the hematocrit, the shear rate and by promoting red blood cell aggregation with the use of agents such as high molecular weight dextran. However, the non Newtonian behavior of blood in tube flow can be seen as a confounding factor to the understanding of the spatial organization of the red blood cell aggregates. In this study, whole blood was circulated in a simple shear flow apparatus, which allowed to homogeneously modulate the red blood cell aggregate sizes and structure, and quantify their effect on the axial migration of blood platelets. Anticoagulated porcine bloods were adjusted to different hematocrits and inserted into a Couette flow apparatus, at room temperature. Blood platelets, difficult to isolate in vitro without activating in a non reproducible manner specific membrane ligands, were replaced with biotin coated fluorescent polystyrene beads. The quantification of the migration of these platelet ghosts was conducted with the use of biological membranes fixed on the interior walls of the Couette apparatus. These streptavidin coated membranes ensure a strong adhesive affinity with the biotynilated beads. At 40% hematocrit and at a shear of 2 s-1, 566 ± 53 micro particles were counted for non aggregated erythrocytes, 1077 ± 229 for aggregating red blood cells and 1568 ± 131 for hyper aggregating blood. The results obtained suggest a strong participation of the red blood cell aggregation on the transport of platelet ghosts since the number of ghost cells fixed on the wall of the Couette rheometer increases almost exponentially with the level of aggregation present.
137

Développement et validation de méthodes visant une utilisation optimale d'antennes réceptrices en imagerie par résonance magnétique

Gilbert, Guillaume 10 1900 (has links)
Différentes méthodes ayant pour objectif une utilisation optimale d'antennes radio-fréquences spécialisées en imagerie par résonance magnétique sont développées et validées. Dans un premier temps, il est démontré qu'une méthode alternative de combinaison des signaux provenant des différents canaux de réception d'un réseau d'antennes mène à une réduction significative du biais causé par la présence de bruit dans des images de diffusion, en comparaison avec la méthode de la somme-des-carrés généralement utilisée. Cette réduction du biais engendré par le bruit permet une amélioration de l'exactitude de l'estimation de différents paramètres de diffusion et de diffusion tensorielle. De plus, il est démontré que cette méthode peut être utilisée conjointement avec une acquisition régulière sans accélération, mais également en présence d'imagerie parallèle. Dans une seconde perspective, les bénéfices engendrés par l'utilisation d'une antenne d'imagerie intravasculaire sont étudiés. Suite à une étude sur fantôme, il est démontré que l'imagerie par résonance magnétique intravasculaire offre le potentiel d'améliorer significativement l'exactitude géométrique lors de mesures morphologiques vasculaires, en comparaison avec les résultats obtenus avec des antennes de surface classiques. Il est illustré qu'une exactitude géométrique comparable à celle obtenue grâce à une sonde ultrasonique intravasculaire peut être atteinte. De plus, plusieurs protocoles basés sur une acquisition de type balanced steady-state free-precession sont comparés dans le but de mettre en évidence différentes relations entre les paramètres utilisés et l'exactitude géométrique obtenue. En particulier, des dépendances entre la taille du vaisseau, le rapport signal-sur-bruit à la paroi vasculaire, la résolution spatiale et l'exactitude géométrique atteinte sont mises en évidence. Dans une même optique, il est illustré que l'utilisation d'une antenne intravasculaire permet une amélioration notable de la visualisation de la lumière d'une endoprothèse vasculaire. Lorsque utilisée conjointement avec une séquence de type balanced steady-state free-precession utilisant un angle de basculement spécialement sélectionné, l'imagerie par résonance magnétique intravasculaire permet d'éliminer complètement les limitations normalement engendrées par l'effet de blindage radio-fréquence de l'endoprothèse. / Specific methods for an optimal use of specialized magnetic resonance radiofrequency coils are developed and validated. First, an improved combination of signals from the different channels of an array coil is shown to lead to a significant reduction of the noise bias in diffusion images, in comparison to the generally accepted sum-of-squares combination method. This reduction of the noise bias is demonstrated to greatly improve the accuracy of the estimated diffusion and diffusion tensor parameters, both for a standard non-accelerated acquisition and when parallel imaging is used. In a second scope, the benefits arising from the use of an intravascular imaging antenna are investigated. Using a phantom study, it is demonstrated that intravascular magnetic resonance imaging offers the potential to improve the geometrical accuracy of morphological vascular measurements in comparison to standard surface magnetic resonance imaging and that a geometrical accuracy comparable to the one obtained using intravascular ultrasound can be reached. Several protocols based on a balanced steady-state free-precession sequence are compared in order to highlight the relations between several acquisitions parameters and the achieved geometrical accuracy. In particular, important relations between the vessel size, the vessel wall signal-to-noise ratio, the in-plane resolution and the achieved accuracy are illustrated. In a similar manner, the use of an intravascular antenna is demonstrated to be highly beneficial for an improved in-stent lumen visualization. When used with a balanced steady-state free-precession acquisition with a carefully chosen flip angle, intravascular magnetic resonance imaging can effectively eliminate the hindering aspect of the radiofrequency shielding effect caused by the presence of the vascular stent.
138

Paramétrisation de la rétrodiffusion ultrasonore érythrocytaire haute fréquence et pertinence comme facteur de risque de la thrombose veineuse

Yu, Francois T.H. 12 1900 (has links)
L’agrégation érythrocytaire est le principal facteur responsable des propriétés non newtoniennes sanguines pour des conditions d’écoulement à faible cisaillement. Lorsque les globules rouges s’agrègent, ils forment des rouleaux et des structures tridimensionnelles enchevêtrées qui font passer la viscosité sanguine de quelques mPa.s à une centaine de mPa.s. Cette organisation microstructurale érythrocytaire est maintenue par des liens inter-globulaires de faible énergie, lesquels sont brisés par une augmentation du cisaillement. Ces propriétés macroscopiques sont bien connues. Toutefois, les liens étiologiques entre ces propriétés rhéologiques générales et leurs effets pathophysiologiques demeurent difficiles à évaluer in vivo puisque les propriétés sanguines sont dynamiques et fortement tributaires des conditions d’écoulement. Ainsi, à partir de propriétés rhéologiques mesurées in vitro dans des conditions contrôlées, il devient difficile d’extrapoler leurs valeurs dans un environnement physiologique. Or, les thrombophlébites se développent systématiquement en des loci particuliers du système cardiovasculaire. D’autre part, plusieurs études cliniques ont établi que des conditions hémorhéologiques perturbées constituent des facteurs de risque de thrombose veineuse mais leurs contributions étiologiques demeurent hypothétiques ou corrélatives. En conséquence, un outil de caractérisation hémorhéologique applicable in vivo et in situ devrait permettre de mieux cerner et comprendre ces implications. Les ultrasons, qui se propagent dans les tissus biologiques, sont sensibles à l’agrégation érythrocytaire. De nature non invasive, l’imagerie ultrasonore permet de caractériser in vivo et in situ la microstructure sanguine dans des conditions d’écoulements physiologiques. Les signaux ultrasonores rétrodiffusés portent une information sur la microstructure sanguine reflétant directement les perturbations hémorhéologiques locales. Une cartographie in vivo de l’agrégation érythrocytaire, unique aux ultrasons, devrait permettre d’investiguer les implications étiologiques de l’hémorhéologie dans la maladie thrombotique vasculaire. Cette thèse complète une série de travaux effectués au Laboratoire de Biorhéologie et d’Ultrasonographie Médicale (LBUM) du centre de recherche du Centre hospitalier de l’Université de Montréal portant sur la rétrodiffusion ultrasonore érythrocytaire et menant à une application in vivo de la méthode. Elle se situe à la suite de travaux de modélisation qui ont mis en évidence la pertinence d’un modèle particulaire tenant compte de la densité des globules rouges, de la section de rétrodiffusion unitaire d’un globule et du facteur de structure. Ce modèle permet d’établir le lien entre la microstructure sanguine et le spectre fréquentiel du coefficient de rétrodiffusion ultrasonore. Une approximation au second ordre en fréquence du facteur de structure est proposée dans ces travaux pour décrire la microstructure sanguine. Cette approche est tout d’abord présentée et validée dans un champ d’écoulement cisaillé homogène. Une extension de la méthode en 2D permet ensuite la cartographie des propriétés structurelles sanguines en écoulement tubulaire par des images paramétriques qui mettent en évidence le caractère temporel de l’agrégation et la sensibilité ultrasonore à ces phénomènes. Une extrapolation menant à une relation entre la taille des agrégats érythrocytaires et la viscosité sanguine permet l’établissement de cartes de viscosité locales. Enfin, il est démontré, à l’aide d’un modèle animal, qu’une augmentation subite de l’agrégation érythrocytaire provoque la formation d’un thrombus veineux. Le niveau d’agrégation, la présence du thrombus et les variations du débit ont été caractérisés, dans cette étude, par imagerie ultrasonore. Nos résultats suggèrent que des paramètres hémorhéologiques, préférablement mesurés in vivo et in situ, devraient faire partie du profil de risque thrombotique. / The aggregation of erythrocytes is the main determinant of blood non Newtonian behaviour under low shearing flow conditions. When red blood cells (RBCs) aggregate, they form « rouleaux » and complex tridimensional structures that increase blood viscosity from a few mPa.s to a hundred mPa.s. The reversible RBC aggregation phenomenon is attributed to weak adhesive links between erythrocytes that are readily broken by increasing flow shearing. Blood bulk rheological properties have been comprehensively studied. However, the in vivo physiological impacts of abnormal clustering of RBCs are more difficult to assess. Clinical studies have identified altered hemorheology as a risk factor for thrombosis, but a clear etiological relationship between abnormal aggregation and thrombosis has not yet been established, in part because clinical conclusions were derived from correlative findings. It is to note that cardiovascular diseases such as deep venous thrombosis generally occur at specific locations within the vascular bed, suggesting a hemodynamic contribution to the development of this disease. Consequently, it is postulated that in vivo hemorheological characterization may help shed some light on the role of RBC hyper-aggregation on cardiovascular disorders. Ultrasound imaging, a non-invasive method relying on the propagation of mechanical waves within biological tissues, is sensitive to RBC aggregation. Indeed, the study of backscattered waves allows characterizing blood microstructure in vivo and in situ under physiological flow conditions. The work described in this thesis is based on prior simulation studies, performed at the Laboratory of Biorheology and Medical Ultrasonics of the University of Montreal Hospital Research Center, in which the backscattering of ultrasound from aggregating RBCs was modeled by considering a particle scattering strategy. In this approach, each RBC is a weak ultrasound scatterer (Born assumption) and the backscattering coefficient is modeled as the product of the RBC number density, the RBC backscattering cross section and a structure factor. This model relates variations in the backscattering coefficient to the RBC spatial organisation through the structure factor, which is the only parameter that changes during the aggregation process. A second order expansion in frequency of the structure factor was used to describe blood microstructure in terms of a packing factor W and an ensemble averaged aggregate diameter D. The model was first presented and validated by considering a homogenous shear flow condition using three broadband mono-element transducers. It was then extended in 2D to allow computation of parametric images in tube flow. An extrapolation based on the assumption that viscosity is related to the level of aggregation was used to compute local viscosity maps. Finally, a last contribution was the demonstration that a sudden increase in aggregation tendency directly promoted the formation of venous thrombosis in an experimental animal model. In that study, RBC aggregation, thrombus formation and flow variations were monitored longitudinally for two weeks using ultrasound. The results reported in this thesis suggest that rheological parameters on RBC clustering, ideally assessed in vivo and in situ, should be included in thrombosis risk profiling.
139

Développement et validation d'un instrument non-invasifde caractérisation du comportement musculaire respiratoire

Aïthocine, Elise 09 1900 (has links)
Les progrès en anesthésie et en réanimation ont pour objectifs la réduction de la durée de surveillance et l'amélioration de la qualité de la récupération. Pour le cas particulier de l'assistance respiratoire, la capacité de surveiller et d'optimiser l'adaptation entre le patient et sa machine d'assistance est déterminante pour la qualité et la conduite des soins. Ce travail de thèse concerne dans sa première partie la mise en place et la validation d'un outil instrumental permettant de caractériser un comportement respiratoire par l'étude cycle à cycle du délai d'activation inspiratoire entre les muscles des voies aériennes supérieures et de la cage thoracique. Cet outil doit prendre en compte les contraintes imposées par le milieu clinique telle qu'une mesure non-invasive des muscles respiratoires. Il repose sur une mesure électromyographique (EMG) de surface des muscles respiratoires. La mesure cycle à cycle et par voie de surface du délai d'activation est un véritable challenge dans un environnement clinique qui est fortement perturbé. La démarche choisie ici est double avec en parallèle : i) La mise en place d'un outil de détection d'évènements menée sous supervision. ii) La définition d'un protocole original sur sujets sains prenant en compte les contraintes cliniques et permettant de valider l'outil et de constituer une base de connaissances pour envisager l'automatisation des procédés dans un travail futur. D'un point de vue physiologique, l'influence de la fréquence respiratoire sur le délai d'activation de l'inspiration n'a pas été étudiée à ce jour. Ce délai a donc été mesuré en condition de normocapnie à différentes fréquences respiratoires imposées par un stimulus sonore. Une étude statistique montre que l'instrument permet de distinguer deux situations physiologiques du protocole expérimental, ce qui en dé- montre la sensibilité. La deuxième partie de ce travail de thèse s'inscrit dans le cadre d'une optimisation des méthodes de détection de singularités d'intérêt. La solution choisie ici se base sur l'intensité structurelle qui calcule la "densité" de maxima d'ondelettes à différentes échelles et permet une localisation des singularités d'un signal bruité. Une formulation de cet outil qui utilise la transformée de Berkner est proposée. Celle-ci permet le chaînage des maxima d'ondelette afin de positionner précisément les amers du signal. Le filtrage de l'artefact ECG dans l'EMG diaphragmatique sans signal de référence est proposé comme exemple d'application. / Better care in an anaesthesia and critical care could be achieved by reducing monitoring duration and improving the quality of recovery. For the particular case of respiratory assistance, the capacity to track and optimize patient-ventilator synchrony is essential to quality care. As a first step, this thesis adresses the development and validation of an instrument which characterizes respiratory behavior by studying the time lag between onset of upper airway muscles and rib cage muscles, cycle by cycle during respiration. This tool must take into account the constraints imposed by the clinical environment ; measuring respiratory muscles by surface electromyographic measurements (EMG). Measurement of the onset time lag, cycle by cycle and non invasively, is a true challenge in a critical care clinical environment. Here the approach is two-fold : i) The development of a tool for events detection. ii) The definition of an original protocol on healthy subjects. The tool development constitutes a knowledge bases to eventually develop automation of the processes in future work. From a physiological point of view, the influence of respiratory rate on the EMG onset time lag during inspiration has not been studied. Thus we measured this time lag in normocapnia at various respiratory rates imposed by a sound stimulus. Statistically, the instrumental tool can distinguish two physiological situations in this experimental protocol, which confirms its sensitivity. The second step of this thesis is part of an optimization of events detection methods with singularities of interest. The chosen solution is based on structural intensity which computes the "density" of the locations of the modulus maxima of a wavelet representation along various scales in order to identify singularities of an unknown signal. An improvement is proposed by applying Berkner transform which allows maxima linkage to insure accurate localization of landmarks. An application to cancel ECG interference in diaphragmatic EMG without a reference signal is also proposed. / Réalisé en cotutelle avec l'Université Joseph Fourier École Doctorale Ingénierie pour la Santé,la Cognition et l'Environnement (France)
140

Optimization and validation of a new 3D-US imaging robot to detect, localize and quantify lower limb arterial stenoses

Janvier, Marie-Ange 10 1900 (has links)
L’athérosclérose est une maladie qui cause, par l’accumulation de plaques lipidiques, le durcissement de la paroi des artères et le rétrécissement de la lumière. Ces lésions sont généralement localisées sur les segments artériels coronariens, carotidiens, aortiques, rénaux, digestifs et périphériques. En ce qui concerne l’atteinte périphérique, celle des membres inférieurs est particulièrement fréquente. En effet, la sévérité de ces lésions artérielles est souvent évaluée par le degré d’une sténose (réduction >50 % du diamètre de la lumière) en angiographie, imagerie par résonnance magnétique (IRM), tomodensitométrie ou échographie. Cependant, pour planifier une intervention chirurgicale, une représentation géométrique artérielle 3D est notamment préférable. Les méthodes d’imagerie par coupe (IRM et tomodensitométrie) sont très performantes pour générer une imagerie tridimensionnelle de bonne qualité mais leurs utilisations sont dispendieuses et invasives pour les patients. L’échographie 3D peut constituer une avenue très prometteuse en imagerie pour la localisation et la quantification des sténoses. Cette modalité d’imagerie offre des avantages distincts tels la commodité, des coûts peu élevés pour un diagnostic non invasif (sans irradiation ni agent de contraste néphrotoxique) et aussi l’option d’analyse en Doppler pour quantifier le flux sanguin. Étant donné que les robots médicaux ont déjà été utilisés avec succès en chirurgie et en orthopédie, notre équipe a conçu un nouveau système robotique d’échographie 3D pour détecter et quantifier les sténoses des membres inférieurs. Avec cette nouvelle technologie, un radiologue fait l’apprentissage manuel au robot d’un balayage échographique du vaisseau concerné. Par la suite, le robot répète à très haute précision la trajectoire apprise, contrôle simultanément le processus d’acquisition d’images échographiques à un pas d’échantillonnage constant et conserve de façon sécuritaire la force appliquée par la sonde sur la peau du patient. Par conséquent, la reconstruction d’une géométrie artérielle 3D des membres inférieurs à partir de ce système pourrait permettre une localisation et une quantification des sténoses à très grande fiabilité. L’objectif de ce projet de recherche consistait donc à valider et optimiser ce système robotisé d’imagerie échographique 3D. La fiabilité d’une géométrie reconstruite en 3D à partir d’un système référentiel robotique dépend beaucoup de la précision du positionnement et de la procédure de calibration. De ce fait, la précision pour le positionnement du bras robotique fut évaluée à travers son espace de travail avec un fantôme spécialement conçu pour simuler la configuration des artères des membres inférieurs (article 1 - chapitre 3). De plus, un fantôme de fils croisés en forme de Z a été conçu pour assurer une calibration précise du système robotique (article 2 - chapitre 4). Ces méthodes optimales ont été utilisées pour valider le système pour l’application clinique et trouver la transformation qui convertit les coordonnées de l’image échographique 2D dans le référentiel cartésien du bras robotisé. À partir de ces résultats, tout objet balayé par le système robotique peut être caractérisé pour une reconstruction 3D adéquate. Des fantômes vasculaires compatibles avec plusieurs modalités d’imagerie ont été utilisés pour simuler différentes représentations artérielles des membres inférieurs (article 2 - chapitre 4, article 3 - chapitre 5). La validation des géométries reconstruites a été effectuée à l`aide d`analyses comparatives. La précision pour localiser et quantifier les sténoses avec ce système robotisé d’imagerie échographique 3D a aussi été déterminée. Ces évaluations ont été réalisées in vivo pour percevoir le potentiel de l’utilisation d’un tel système en clinique (article 3- chapitre 5). / Atherosclerosis is a disease caused by the accumulation of lipid deposits inducing the remodeling and hardening of the vessel wall, which leads to a progressive narrowing of arteries. These lesions are generally located on the coronary, carotid, aortic, renal, digestive and peripheral arteries. With regards to peripheral vessels, lower limb arteries are frequently affected. The severity of arterial lesions are evaluated by the stenosis degree (reduction > 50.0 % of the lumen diameter) using angiography, magnetic resonance angiography (MRA), computed tomography (CT) and ultrasound (US). However, to plan a surgical therapeutic intervention, a 3D arterial geometric representation is notably preferable. Imaging methods such as MRA and CT are very efficient to generate a three-dimensional imaging of good quality even though their use is expensive and invasive for patients. 3D-ultrasound can be perceived as a promising avenue in imaging for the location and the quantification of stenoses. This non invasive, non allergic (i.e, nephrotoxic contrast agent) and non-radioactive imaging modality offers distinct advantages in convenience, low cost and also multiple diagnostic options to quantify blood flow in Doppler. Since medical robots already have been used with success in surgery and orthopedics, our team has conceived a new medical 3D-US robotic imaging system to localize and quantify arterial stenoses in lower limb vessels. With this new technology, a clinician manually teaches the robotic arm the scanning path. Then, the robotic arm repeats with high precision the taught trajectory and controls simultaneously the ultrasound image acquisition process at even sampling and preserves safely the force applied by the US probe. Consequently, the reconstruction of a lower limb arterial geometry in 3D with this system could allow the location and quantification of stenoses with high accuracy. The objective of this research project consisted in validating and optimizing this 3D-ultrasound imaging robotic system. The reliability of a 3D reconstructed geometry obtained with 2D-US images captured with a robotic system depends considerably on the positioning accuracy and the calibration procedure. Thus, the positioning accuracy of the robotic arm was evaluated in the workspace with a lower limb-mimicking phantom design (article 1 - chapter 3). In addition, a Z-phantom was designed to assure a precise calibration of the robotic system. These optimal methods were used to validate the system for the clinical application and to find the transformation which converts image coordinates of a 2D-ultrasound image into the robotic arm referential. From these results, all objects scanned by the robotic system can be adequately reconstructed in 3D. Multimodal imaging vascular phantoms of lower limb arteries were used to evaluate the accuracy of the 3D representations (article 2 - chapter 4, article 3 - chapter 5). The validation of the reconstructed geometry with this system was performed by comparing surface points with the manufacturing vascular phantom file surface points. The accuracy to localize and quantify stenoses with the 3D-ultrasound robotic imaging system was also determined. These same evaluations were analyzed in vivo to perceive the feasibility of the study.

Page generated in 0.0849 seconds