• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 639
  • 7
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 656
  • 403
  • 112
  • 66
  • 62
  • 47
  • 46
  • 43
  • 39
  • 39
  • 37
  • 36
  • 33
  • 32
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

Desenvolvimento de um leitor digital de absorbância microprocessado / SILVA, A. J. Development of a digital reader Absorbance microprocessor . Dissertation (Master) Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto - SP, 2011.

Silva, Aldriano José da 04 March 2011 (has links)
O espectrofotômetro, aparelho muito utilizado para realizar leituras de absorbância e/ou transmitância de amostras laboratoriais, pode ser aplicado para a realização de leituras do dosímetro químico Fricke Xilenol Gel. Este aparelho, por possuir componentes eletrônicos avançados e ser importado, apresenta um custo elevado e acaba muitas vezes se tornando um dispositivo inviável para medidas mais simples e rotineiras. O presente estudo implementou-se um aparelho portátil e de baixo custo, para que medidas específicas de absorbância possam ser feitas em laboratórios de ensino de física e que possa ser aplicado como leitor de dosímetros géis, como o acima citado. Este monoespectrofotômetro é constituído por uma fonte LED (próximo a 590 nm), um fotodiodo para avaliação da intensidade da luz transmitida e um display de LCD. Tal leitor permite a comunicação com microcomputadores via porta USB, facilitando o trabalho do usuário para manipular os resultados das medidas. A principal finalidade é voltada para uso acadêmico, no entanto, devido ao seu baixo custo e simplicidade, poderá também ser direcionado para atender outros segmentos como ambulatorial, industrial, cosmético, biológico, agronômico, dentre outros. / The spectrophotometer, a device often used to perform absorbance readings and or transmittance of laboratory samples, can be applied to perform readings in the chemical dosimeter Fricke Xylenol Gel. This device, once it has advanced electronics components and is imported, has an elevated cost and often ends up becoming an impractical device for most simple measurements and routine. This study implemented a device portable and inexpensive, so that specific measurements absorbance can be made in teaching laboratories of physics and that can be applied as a gel dosimeter reader, like the above. This monospectrophotometer consists of a LED source of visible light (near 590 nm), a photodiode to assess the intensity of transmitted light and an LCD display. This reader allows communication with computers via USB port, making it easier for users to manipulate the results of the measurements. The main purpose is directed for academic use, however, due to its low cost and simplicity, may also be applied to attend other segments such as outpatient, industrial, cosmetic, biological, agronomic, among others.
262

Estudo de gradientes térmicos e deformações em "whitetopping" ultradelgado. / Thermal gradients and deformations in ultra-thin witetopping.

Pereira, Deividi da Silva 10 March 2001 (has links)
Propiciado pela construção de uma pista experimental inteiramente instrumentada com medidores de deformação e de temperatura na Cidade Universitária, este trabalho buscou o entendimento de inúmeros fatores intervenientes no desempenho do whitetopping ultradelgado, recente técnica de manutenção de pavimentos asfálticos com a utilização de delgadas placas de concreto, sob tráfego característico urbano, em condições tipicamente tropicais de uso, sobre uma pequena espessura de concreto asfáltico remanescente de fresagem. Com o intuito de nortear o problema em questão, além da revisão bibliográfica, foram realizados levantamentos periódicos das condições estruturais e funcionais deste pavimento; leituras contínuas de temperaturas e deformações obtidas por meio de um sistema automatizado de captação de dados junto aos instrumentos colocados no interior das placas; caracterização dos gradientes térmicos presentes nas placas durante as diferentes estações climáticas do ano. Foram realizadas provas de carga, estáticas e dinâmicas, com intuito de verificar os reais níveis de deformação aos quais as placas estariam sujeitas quando da interação com o tráfego; posteriormente, realizou-se modelagem numérica por meio de um programa de elementos finitos objetivando uma comparação com os dados obtidos nas provas de carga, analisando inclusive o posicionamento da linha neutra neste pavimento composto. Por fim, em uma sucinta abordagem sobre as deflexões antes e depois da execução do whitetopping ultradelgado, observou-se o tipo de comportamento estrutural do pavimento nas condições em que o experimento foi realizado. Ao término da pesquisa, inferiu-se que os gradientes térmicos dependem de vários fatores climáticos que não somente a temperatura ambiente, importando também a irradiação solar, o número de horas de sol, a velocidade de crescimento e decréscimo da temperatura ambiente; os gradientes térmicos encontrados não são importantes para o acréscimo nos níveis de tensões nas placas, não alterando assim a vida à fadiga do whitetopping ultradelgado, considerada a magnitude destes gradientes, as diminutas dimensões das placas e ainda a presença de aderência na interface concreto e concreto asfáltico. Em provas de carga, concluiu-se que os valores de tensões obtidos em campo mantêm grandezas semelhantes com os provenientes de modelos numéricos e ainda observou-se o vasto potencial de utilização das provas dinâmicas. Dado o excelente desempenho observado nas condições do experimento, mesmo com as placas aderidas a uma delgada camada asfáltica, fator que diferentemente do relatado no exterior não comprometeu o desempenho, não foi possível fazer uma avaliação em termos funcionais do desempenho deste tipo de pavimento. Verificou-se a significativa redução nas deflexões após a execução das placas, visualizando inclusive a transferência de cargas entre sucessivas placas, quando mantida a integridade estrutural das demais camadas do pavimento. / In this work, several factors affecting behavior and performance of ultra-thin whitetopping were evaluated taking advantage of a full scale experimental pavement, restored by applying such technique. Temperatures and thermal gradients in concrete thin slabs were evaluated by almost one year, comprising al the seasons. Load tests were carried out to allow strains measurements on concrete as well to define the deflection basins on whitetopped pavements. The experimental research has permitted to verify the dependence of thermal gradients on air temperature and solar radiation among other factors. It was observed that the thermal gradients practically do not affect behavior of the thin slabs. Stresses received from load tests compared to finite element generated stresses shown to maintain a good and closed relation. Due to good performance observed along the experiment it became not possible to establish patterns of functional performance. Expressive decrease of deflection level was observed over concrete overlays allowing to infer some load transfer on joints when the slabs are to be laid over non distressed old asphalt pavements.
263

Avaliação da qualidade de margem de preparos cavitários realizados com diferentes técnicas e instrumentos / Margin quality of cavity preparations with different techniques and instruments

Francischone, Ana Carolina 11 September 2009 (has links)
Há mais de 50 anos, a Odontologia usa a mesma tecnologia para a preparação de cavidades, que é a alta velocidade com ponta diamantada e brocas carbides. Novos estudos e novas técnicas têm sido proporcionada para que haja uma opção a mais para esse procedimento no tratamento para os pacientes. Surgiram, então, novas tecnologias no mercado odontológico para eliminação mecânica da cárie e preparação de cavidades, como alta pressão de ar associado a jato de areia, aparelho de Laser, contra- ângulo multiplicador e ultrassom associado a pontas diamantadas. Mas por serem tecnologias novas, há ainda necessidade de pesquisas para a constatação de que realmente poderão vir a ser técnicas alternativas ou até substituir a tecnologia clássica que vem sendo utilizada com bons resultados. Assim, o propósito desta pesquisa foi avaliar, através de microscopia eletrônica de varredura (MEV), as margens cavitárias com e sem acabamento, realizadas com pontas diamantadas e CVDentus, associadas a diferentes tipos de dispositivos e mecanismo de ação. Os resultados encontrados mostraram não haver diferenças estatisticamente significantes (p<0.05) entre as condições testadas, nas comparações individuais, com exceção dos grupos G4 x G7 (Alta velocidade+ Ponta Diamantada Preparo + Baixa Rotação + Ponta Diamantada para acabamento x Ultrassom + CVDentus Preparo 50% + Contra-ângulo). Concluiu-se que todas as formas de acabamento das margens cavitárias, testadas nesta pesquisa, são confiáveis e podem ser utilizadas. O uso do aparelho de ultrassom deve ser recomendado nas potências variando entre 50% a 75% para preparos cavitários. / For more than 40 years, dentistry has used the same technology for cavity preparation, high-speed rotation systems with diamond burs. New studies and techniques have been performed to develop a new treatment option for patients. Thus, new technologies have been possible such as high pressure sandblasting systems, laser devices, multiplying low-speed rotation, and finally, the ultra-sound with diamond burs. However, whether these new technologies can be an alternative or substitute for old practices with standard results is not known. The aim of this study was to evaluate by SEM cavity preparation margins with and without finishing, made by diamond burs and the CVDentus system associated to different devices and action forms. The results showed no statistically significant differences (p<.05) among the tested conditions on individual comparisons, except for GIV x GVII (highspeed rotation plus diamond bur + low-speed rotation plus diamond finishing bur x ultra-sound plus CVDentus 50% power plus low-speed rotation). It was concluded that all finishing modes on margin cavities are reliable and can be used in clinical practice. The use of the ultra-sound device can be recommended within 50-75% power for cavity preparations.
264

Desenvolvimento de metodologia eletroanalítica para a determinação do herbicida glifosato / Development of electroanalytic methodology for determination of the herbicide glyphosate

Coutinho, Cláudia Flávia Breda 22 August 2008 (has links)
Neste trabalho, são abordados os estudos relativos a interação entre Cu(II) e glifosato e também o desenvolvimento de metodologias eletroanalíticas para determinação do herbicida glifosato. Inicialmente, o complexo Cu(II)-glifosato foi estudo por meio de técnicas espectrofotométricas e eletroanalíticas (voltametria de onda quadrada) e encontrou-se os valores de comprimento de onda máximo do complexo (231 e 731 nm) e também o valor da constante de estabilidade condicional do complexo 1:1 Cu(II)-glifosato (log K = 7,9). O estudo inicial da interação entre glifosato e o microeletrodo de cobre, em meio de tampão fosfato, mostrou que o herbicida dissolve a camada de óxidos, aumentando a corrente anódica do microeletrodo, levando a formação de um complexo solúvel entre Cu(II) e glifosato. Esta interação foi estuda por meio de técnicas voltamétricas, curvas de polarização, espectroscopia de impedância eletroquímica, voltametria hidrodinâmica, entre outras. Estes estudos complementares forneceram dados importantes sobre o processo de dissolução causado pelo glifosato, tais como, potencial de corrosão, densidade de corrente de corrosão e inclinação de Tafel, valores de resistência de transferência de carga e constante aparente de transferência eletrônica, coeficiente de difusão do complexo e constante de velocidade aparente da reação, além de imagens de microscopia eletrônica de varredura e de microscopia de força atômica do processo de corrosão do cobre. Após estudar este processo de dissolução, esta reação foi utilizada para o desenvolvimento de uma metodologia de análise de glifosato utilizando detecção coulométrica com (micro)eletodo de cobre aliada a cromatografia líquida. A instrumentação (software, célula eletroquímica e minipotenciostato) desenvolvida neste trabalho foi utilizada com sucesso na determinação de glifosato em amostras de alimentos e água. As metodologias de análise de glifosato utilizando detecção coulométrica com (micro)eletrodo de cobre aliada a cromatografia liquida, apresentaram limites de detecção adequados para a análise deste herbicida em diversas matrizes (100 &micro;g L-1 para sucos de frutas, 32 &micro;g L-1 e 1,9 &micro;g L-1 para amostras de água e 53 &micro;g Kg-1 para amostras de soja). A detecção coulométrica com micro(eletrodo) de cobre apresentou algumas vantagens sobre a detecção com métodos ópticos, tais como, análise direta e rápida, ou seja, não são necessárias demoradas reações de derivatização da amostra; sem etapas de extração/limpeza da amostra; pré-concentração optativa; baixo custo das análises, quando comparado aos preços dos reagentes de derivatização e instrumentação simples e de baixo custo. / In this work, the interaction between Cu(II) and glyphosate was investigated and electroanalytical methodologies was developed for determination of this herbicide. Initially, the Cu(II)-glyphosate complex was studied through spectrophotometric and electroanalytical techniques (square wave voltammetry) and it was found the values of maximum wavelength of the complex (231 and 731 nm) and also the value for the constant of conditional stability of the 1:1 Cu(II)-glyphosate complex (log K = 7,9). The initial study of the interaction between glyphosate and the copper microelectrode, in phosphate buffer, showed that the herbicide dissolves the layers of oxides, increasing the anodic current of the microelectrode, taking the formation of a soluble complex between Cu(II) and glyphosate. This interaction was studies through cyclic voltammetry, polarization curves, electrochemical impedance espectroscopy, hydrodynamic voltammetry, among others. These complemental studies supplied important data about the electrode dissolution process caused by glyphosate, such as, corrosion potential, density of corrosion current and Tafel slope, resistance of heterogeneous charge-transfer reaction, diffusion coefficient of the complex and apparent rate constant of reaction, besides images of scanning electron microscopy and of atomic force microscopy of the corrosion process for metallic copper. After studying the copper dissolution process, this reaction was used for the development of a new methodology for glyphosate analysis using coulometric detection with copper microelectrode allied to the liquid chromatography The instrumentation (software, electrochemical cell and a minipotentiostat) developed in this work was used with success in the determination of glyphosate in samples of foods and water. The methodologies of glyphosate analysis using coulometric iv detection with copper microelectrode allied to the liquid chromatography, presented appropriate detection limits for the analysis of this herbicide in several matrixes (100 &micro;g L-1 for fruit juices, 32 &micro;g L-1 and 1,9 &micro;g L-1 for water samples and 53 &micro;g Kg-1 for soy samples). The coulometric detection with copper microelectrode presented some advantages when compared with the detection with optical methods, such as, direct and fast analysis, in other words, it is not necessary derivatization reaction of the sample; without extraction/clean-up step of the sample; the sample pre-concentration is optional; low cost of the analyses, when compared to the prices of the derivatization reagents and simple and low cost instrumentation.
265

Uma contribuição à instrumentação para o monitoramento do processo de fresamento de topo. / A contribution of instrumentation for process monitoring of end mills.

Flores Cisneros, César Abraham 28 July 2006 (has links)
A cadeia da instrumentação para o monitoramento do desgaste da ferramenta por emissão acústica está constituída por sensores, condicionador de sinal, conversor A/D e transmissor. A seleção ou projeto de cada uma das etapas é de suma importância para manter o conteúdo do sinal de emissão acústica (neste caso a fonte de emissão acústica é a usinagem). O sinal de emissão acústica de interesse tem componentes que vão dos 100kHz a 1 MHz. Devido às características do projeto, são desenvolvidos o condicionador e o transmissor. São apresentados os projetos do pré-amplificador e filtro (que pertencem ao condicionador), os quais realizam suas respectivas funções de amplificação e filtragem. O pré-amplificador, cuja função é a de fortalecer o sinal fraco na saída do sensor, amplifica o sinal em 20 dB. Ele tem uma resposta plana na faixa de interesse (freqüências inferiores a 1 MHz). O filtro, que é do tipo banda passante, tem por função eliminar as componentes vinculadas às vibrações mecânicas e os ruídos elétricos e eletromagnéticos, assim como evitar o fenômeno do \"aliasing\" no processamento do sinal. Ele não deixa passar as componentes do sinal de freqüências inferiores a 100 kHz e superiores a 1 MHz. Tem uma resposta plana na banda de interesse, o que garante a manutenção do formato do sinal. São consideradas nos projetos indicados as respostas dos componentes eletrônicos para as freqüências de trabalho e a proteção dos circuitos contra ruídos na alimentação dos mesmos. / The instrumentation for tool wear monitoring by acoustic emission is composed by sensors, signal conditioner, A/D converter and transmitter. The selection or project of each step is very important to keep the container of acoustic emission signal (in this case the source of acoustic emission is the metal cutting). The interesting acoustic emission signal has its components, which comes from 100 kHz to 1 MHz. In spite of the project characteristics, the conditioner and the transmitter are developed. The projects of the pre-amplifier and the filter are presented (they belong to the conditioner), which makes their functions of amplification and filtration. The pre-amplifier, which function is to amplify the weak signal on the output of the sensor, amplifies the signal by 20 dB. It has a flat response on the frequency range (frequencies less than 1 MHz). The filter, which is the type of flat-band, has the function of eliminating the components connected to the mechanic vibrations and the electric/electromagnetic noises, therefore to avoid the aliasing phenomenon on the signal processing. It attenuates the signal components of frequencies lower than 100 kHz and higher than 1 MHz. There is a flat response on the frequency range, which warrants the maintenance of the signal format. It is considered into the projects indicated the electronic components\' responses to the work frequencies and the circuit protection against noises into their feeding.
266

Sistemas de sensoriamento embarcado para uso em controle de aplicações de insumos agrícolas à taxa variável / On board sensing system to control variable rate agricultural inputs

Tangerino, Giovana Tripoloni 08 October 2009 (has links)
O desenvolvimento de sistemas com capacidade de unir ferramentas tecnológicas é de grande importância para oferecer apoio à Agricultura de Precisão e estimular a criação de grupos interdisciplinares para obter resultados favoráveis à produtividade agrícola. O objetivo desse trabalho é estudar as aplicações de sensoriamento embarcado em máquinas agrícolas, explorando a interface da agricultura com a computação e as engenharias mecânica e elétrica por meio de conceitos e tecnologias de sistemas de medidas. Foram desenvolvidos dois sistemas de sensoriamento embarcados. No primeiro realizou-se coleta de informações sobre refletância e altura das plantas em cultura de cana-de-açúcar. No segundo realizou-se coleta de informações e controle de aplicação de fertilizantes à taxa variável baseado em informações de refletância em cultura de milho. Utilizou-se os sensores Crop Circle (medidas de refletância para monitoramento de status da planta), Sonar (medida de altura de plantas) e GPS (Sistema de Posicionamento Global), com os quais foram realizados ensaios para determinar possíveis fontes de erro em uma operação agrícola. Os sistemas desenvolvidos cumpriram o papel de integradores de conhecimento, possibilitando observações práticas sobre necessidades, falhas e acertos no desenvolvimento de sistemas embarcados para uso em aplicações agrícolas / The development of systems able to join different technological tools is very important in order to provide support for Precision Agriculture and it stimulates the creation of interdisciplinary teams to obtain favorable results to increase agricultural productivity. The main goal of this work is to study applications of embedded sensing systems in agricultural machines, exploring the interface between computer science, mechanical, electrical, and agricultural engineering using concepts and technologies of measurement systems. It was developed two on board sensing systems. The first system collected the data of crop reflectance and plant height in sugar cane growing area. The second one controlled the variable rate fertilizer distribution based on reflectance of maize crop. Were used the sensors Crop Circle (reflectance to monitor the status of the plant), Sonar (plant height) and GPS (Global Positioning System), which were applied to detect some possible error sources during field operation. The systems developed fulfilled the role of integrating knowledge, providing practical observations about the needs, failures and successes in developing embedded systems for use in agricultural production
267

Amplificador para registro de potenciais corticais

CARDOSO, Marcelo Ramos 02 February 2005 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-01-08T17:27:39Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-01-16T15:29:40Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5) / Made available in DSpace on 2013-01-16T15:29:40Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AmplificadorRegistroPotenciais.pdf: 1573358 bytes, checksum: c63088be31befb563c0bd2c13bcb865f (MD5) Previous issue date: 2005 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Vários órgãos do corpo humano manifestam suas funções por meio de atividades elétricas. A medição desses e de outros biopotenciais pode fornecer indícios importantes que permitem o estudo do funcionamento real dos órgãos. Tais medições não constituem tarefa simples porque envolvem aquisição de dados de sinais cujas amplitudes podem ser na faixa entre 1 μV e 10 mV e também porque, no ambiente em que são feitos esses registros, estão presentes diversos tipos de sinais interferentes que causam degradação da relação sinal/ruído. Logo, o projeto do condicionador de biopotencial deve ser cercado de cuidados para que o circuito final reúna as melhores características de desempenho. Neste trabalho apresenta-se um estudo da origem dos biopotenciais, suas características, os circuitos utilizados para ganho e filtragem do sinal, além das interferências presentes nos sistemas de medições e alguns circuitos para redução desses sinais. É desenvolvido então, um condicionador para registro de biopotenciais corticais com blocos de filtragem e ganho do sinal em até 40 000. Os testes com o condicionador foram realizados registrando o potencial cortical provocado visual e o eletroencefalograma, e nos resultados experimentais é possível observar um desempenho satisfatório do equipamento. / Many organs in the human body manifest their functions through electric activities. Measurements of these and other biopotentials can provide vital clues that permits study as real functions of the organs. These measurements are not an easy task because envolves extremely low amplitudes data acquisition, between 1 μV and 10 mV, and also because these bioelectric recordings are often disturbed by an excessive level of interference presents, resulting in signal/noise degradation. Therefore, the biopotential amplifier project must be associated with precaution to final circuit can meet great characteristics in such signals measureming. This work shows a study about biopotentials origins, their characteristics, circuits used in signal amplifiering and filtering, interferences present in measurement systems and some circuits used to reduce such interferences. Thereafter, is developed a cortical biopotential amplifier with filtering and gain blocks. The tests with amplifier where realized by registering a visual evoked potential and the electroencephalogram. In the experimental results is possible to observe a satisfactory equipment performance.
268

Avaliação do uso do laser de Er: YAG sobre a remoção da camada de 'smear' das paredes dos canais radiculares com achatamento mésio-distal submetidos à instrumentação rotatória / Evaluation of the use of the laser of Er: YAG on the removal of the layer of ' smear ' of the walls of the roots canals with mesio-distal flattening submitted to the rotatory instrumentation.

Fabio Heredia Seixas 02 October 2003 (has links)
No tratamento endodôntico, várias fases de igual importância são necessárias para a realização de uma terapêutica bem sucedida, entre elas podemos citar a instrumentação. Apesar de todas as técnicas e instrumentos propostos para a Endodontia, o sucesso esperado ainda não foi alcançado. Tanto a instrumentação manual quanto à rotatória não resulta na limpeza das áreas polares dos canais radiculares com achatamento mésio-distal. No intuito de obter melhor resultado clínico, avaliou-se “in vitro” a remoção da camada de “smear” das paredes dos canais radiculares de 40 dentes incisivos inferiores portadores de achatamento mésio-distal submetidos à instrumentação rotatória por meio da técnica “Free Tip Preparation”, utilizando o laser de Er: YAG nos parâmetros de 140 e 250 mJ. Para tanto, a fibra óptica do aparelho foi deslocada lentamente, com velocidade de 2 mm/s, até o orifício cervical na câmara pulpar, na parede vestibular e lingual da raiz; e sua eficácia na remoção da “smear” foi comparada aos grupos onde se utilizou apenas Hipoclorito a 2,5% e Hipoclorito de sódio a 2,5% alternado com EDTA a 17%. Os dentes foram analisados por meio de microscopia eletrônica de varredura, e as fotomicrografias das áreas mais representativas dos terços médio e apical foram avaliadas por três examinadores diferentes, com grau mínimo de Mestre, que observaram a quantidade da camada de “smear” presente nas amostras em relação a três padrões. Os examinadores, sem que tivessem o conhecimento prévio de qual dos grupos estavam avaliando, atribuíram escores de 1 a 4 as fotomicrografias, de acordo com a quantidade da camada de “smear” visualizada. Os dados obtidos foram submetidos à análise estatística não-paramétrica, comparando-se os diferentes grupos estudados (teste de Kruskal-Wallis) e os terços radiculares (teste de Wilcoxcon). Os resultados mostraram que, quanto à quantidade da “smear” encontrada nos grupos estudados, o grupo que utilizou Hipoclorito a 2,5% alternado com EDTA apresentou os canais radiculares mais limpos seguido do grupo do laser 250 mJ e posteriormente pelos grupos do laser Er: YAG a 140 mJ e do hipoclorito a 2,5%, que não apresentaram diferença estatisticamente significante entre si. Quanto aos terços, o apical apresentou maior quantidade da “smear” em comparação com o terço médio (p< 0,01). / Manual or rotary instrumentation techniques do not efficiently clean mesio-distal flattened root canals. This study evaluated, in vitro, smear layer removal of 40 mesio-distal flattened root canals after rotary instrumentation. The teeth were then divided into 4 groups: group 1: rotary instrumentation and 2.5% sodium hypochlorite used as irrigating solution; group 2: instrumented as group 1 and followed by Er: YAG laser irradiation (140mJ input/10Hz), withdrawn at 2mm/s from the apical to the cervical region touching the buccal walls the procedure was then repeated for the lingual wall); group 3: instrumented as group 1 and followed by Er: YAG laser irradiation (250mJinput/10Hz) withdrawn at 2mm/s from the apical to the cervical region touching the buccal walls the procedure was then repeated for the lingual wall) and group 4: instrumented as group 1 and alternated with 17% EDTA Teeth were split longitudinally and prepared for examination under scanning electron microscopy. Scores from 1 to 4 were given to the fotomicrographs by three independent evaluators, and these data was submitted to statistical analysis. The teeth where alternated 17% EDTA were used (group 4) showed less amount of smear layer, followed by the group irradiated with 250mJinput/10Hz (group 3), the group irradiated with 140mJ input/10Hz and the group where only sodium hypochlorite was used. The apical third presented more smear layer than the middle third (p<00.1).
269

Estudo da detecção eletroquimica, empregando eletrodos modificados com policinilina, tendo em vista o desenvolvimento de microssensores para a detecção de aditivos alimentares

Igarashi, Massaki de Oliveira January 2009 (has links)
Orientador: Roberto Jacobe Rodrigues. / DIssertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Engenharia da Informação, 2009.
270

Monitoramento de sinais biomédicos baseado em computação móvel

SERIGIOLI, Nilton January 2011 (has links)
Orientador: Rodrigo Reina Muñoz. / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Engenharia da Informação.

Page generated in 0.0965 seconds