• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • Tagged with
  • 73
  • 73
  • 47
  • 38
  • 32
  • 30
  • 22
  • 19
  • 16
  • 15
  • 15
  • 14
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Duração da ventilação mecânica em pediatria: impacto da introdução de avaliações diárias e teste de respiração espontânea / The impact of daily evaluation and spontaneous breathing test on the duration of pediatric mechanical ventilation: A randomized controlled trial

Flavia Andrea Krepel Foronda 25 April 2013 (has links)
Introdução: Ventilação mecânica (VM) é frequente em crianças com insuficiência respiratória aguda e está associada a complicações, sendo, portanto, necessários esforços para encurtar a sua duração. Objetivos: Verificar se a realização de avaliações diárias e testes de respiração espontânea (TRE), poderiam encurtar a duração da VM em crianças, quando comparado ao desmame habitualmente realizado em pediatria. Objetivos secundários incluíram a avaliação da taxa de falha de extubação e a necessidade de ventilação não invasiva (VNI). Desenho: Estudo prospectivo, randomizado, controlado. Ambiente: Duas unidades de cuidados intensivos pediátricos, em Hospitais Universitários no Brasil. Pacientes: Crianças entre 28 dias e 15 anos de idade que estavam recebendo VM por pelo menos 24 horas no período de julho 2007 a julho 2009. Intervenções: Os pacientes foram aleatoriamente designados para um dos dois protocolos de desmame. No grupo de teste, as crianças foram submetidas a avaliações diárias para verificar prontidão para desmame, depois foi realizado TRE com pressão de suporte de 10 cm H2O e PEEP de 5 cm H2O por um período de 2 horas. O TRE foi repetido no dia seguinte nas crianças que não passaram no primeiro teste. No grupo controle, o desmame foi realizado por critérios clínicos e laboratoriais como de rotina nas unidades. Resultados: 294 crianças elegíveis foram randomizadas, sendo 155 para o grupo de teste e 139 para o grupo controle. O tempo de VM foi menor no grupo de teste onde a duração mediana foi de 3,5 dias (95% intervalo de confiança [IC]: 3,0-4,0) em comparação com o grupo controle onde a mediana do tempo de VM foi de 4,7 dias (95% IC: 4,1-5,3) (p = 0,013). Esta redução significativa na duração da VM não foi associada a um aumento das taxas de falha de extubação ou VNI e representa uma redução de 30% no risco de permanecer em VM (Risco Relativo: 0,70). Conclusões: A avaliação diária para verificar a prontidão para o desmame combinada ao TRE reduziu a duração de VM em crianças, sem aumentar a taxa de falha de extubação ou a necessidade de VNI / Introduction: Mechanical ventilation (MV) is common in children with acute respiratory failure and is associated with several complications requiring efforts to shorten its duration. Objectives: To assess whether the combination of daily evaluation and use of a spontaneous breathing test (SBT) could shorten the duration of mechanical ventilation as compared with weaning based on our standard of care. Secondary outcome measures included extubation failure rate and the need for noninvasive ventilation (NIV).Design: A prospective, randomized, controlled trial. Setting: Two pediatric intensive care units at university hospitals in Brazil. Patients: The trial involved children between 28 days and 15 years of age who were receiving MV for at least 24 hours. Interventions: Patients were randomly assigned to one of two weaning protocols. In the test group, the children underwent a daily evaluation to check readiness for weaning and then submitted to an SBT with 10 cm H2O pressure support and a PEEP of 5 cm H2O for 2 hours. The SBT was repeated the next day for children who failed it. In the control group, weaning was performed according to standard care procedures. Measurements and main results: A total of 294 eligible children were randomized, with 155 to the test group and 139 to the control group. The time to extubation was shorter in the test group, where the median MV duration was 3.5 days (95% confidence interval [CI], 3.0 to 4.0) as compared to 4.7 days (95% CI, 4.1 to 5.3) in the control group (p=0.0127). This significant reduction in the MV duration for the intervention group was not associated with increased rates of extubation failure or NIV. It represents a 30% reduction in the risk of remaining on MV (hazard ratio: 0.70). Conclusions: A daily evaluation to check readiness for weaning combined with a SBT reduced the MV duration for children on MV for more than 24 hours, without increasing the extubation failure rate or the need for NIV
52

Ventilação mecânica não-invasiva em crianças com insuficiência respiratória aguda: uma revisão sistemática da literatura / Non invasive ventilation for children with acute respiratory failure: a systematic rewiew

Carolina Silva Gonzaga 12 December 2007 (has links)
INTRODUÇÃO: A ventilação não-invasiva consiste na aplicação de pressão positiva na via aérea do paciente através de máscaras e interfaces sem a utilização de uma cânula intratraqueal. A presença da cânula na traquéia e outros fatores relacionados à ventilação invasiva convencional são responsáveis por diversas complicações. O uso da ventilação não-invasiva e o desenvolvimento de estudos sobre o tema têm aumentado nos últimos anos, com o objetivo de prevenir ou amenizar as complicações da ventilação invasiva. Em grupos selecionados de pacientes adultos, a ventilação nãoinvasiva é responsável pela diminuição da necessidade de intubação, mortalidade e custos hospitalares. Em pediatria, o número de estudos ainda é reduzido. OBJETIVOS: 1) Descrever os aspectos gerais relacionados ao uso da ventilação não-invasiva (interfaces, ventiladores, modos, pressões, tempo de uso e cuidados) em crianças e adolescentes com insuficiência respiratória aguda. 2) Avaliar a eficácia e a efetividade do uso da ventilação não-invasiva em crianças e adolescentes com insuficiência respiratória aguda. 3) Descrever as complicações da ventilação não-invasiva em crianças e adolescentes com insuficiência respiratória aguda. METODOLOGIA: Foi realizada uma revisão sistemática da literatura nas seguintes bases de dados: Medline, Lilacs, Embase e Colaboração Cochrane, no período de 1966 a maio de 2006, utilizando os seguintes termos: ventilação não-invasiva, CPAP, BIPAP, falha respiratória aguda, hipoxemia e hipercapnia. Os desfechos analisados incluíam: necessidade de intubação, mortalidade, efeitos sobre a oxigenação e ventilação. RESULTADOS: Das 120 publicações encontradas, 11 foram incluídas nesta revisão, sendo um ensaio clínico randomizado, uma revisão sistemática e nove séries de casos, envolvendo um total de 145 pacientes. A ventilação não-invasiva acarretou melhora clínica, e gasométrica dos pacientes. Apenas quatro, dos cento e quarenta e cinco pacientes, morreram. A maioria dos estudos, porém, não tinha grupo controle, o que impossibilitou uma análise da relação causal entre a ventilação não-invasiva em estudo e os efeitos encontrados. CONCLUSÕES: Devido ao reduzido número de ensaios clínicos randomizados, os dados mais atuais sugerem que a ventilação não-invasiva é ainda uma terapia experimental para crianças com IRtA / INTRODUCTION: The non invasive ventilation consists of the application of positive pressure in the airway of the patient through masks and interfaces without the use of a traqueal cannula. The presence of the cannula in the trachea and other factors related to the conventional invasive ventilation is responsible for diverse complications. The use of the non invasive ventilation and the development of studies on the subject have increased in the last years, with the objective to prevent and to brighten up the complications of the invasive ventilation. In selected groups of adult patients use of non invasive ventilation provides effective respiratory support while avoiding the need for endotracheal intubation and mortality decrease. OBJECTIVES: 1) Describe the general aspects related to the use of the non invasive ventilation (interfaces, fans, ways, pressures, time of use and cares) in children and adolescents with acute respiratory insufficience. 2) Avaliar the efficacy and the effectiveness of the use of the non invasive ventilation in children and adolescents with acute respiratory insufficience. 3) Describe the complications of the non invasive ventilation in children and adolescents with acute respiratory insufficience. METHODOLOGY: The medology consisted of a systematic review of literature on non invasive ventilation. The research was performed using: Medline, Lilacs, Embase and Cochrane Collaboration in the period of 1966 to the May of 2006, using the following terms: non invasive ventilation, CPAP, BIPAP, acute respiratory failure, hipoxemia and hipercapnia. The outcomes evaluted were: necessity of endotracheal intubation, mortality, effect on the oxygenation and ventilation. RESULTS: Of the 120 publications founded, 11 were to analyse the eficacy of the non invasive ventilation in the treatment of acute respiratory failure in pediatric patients. Of the 11 clinical trials, one was systematic review, one was randomized clinical trial and six were case series, involving a total of 145 patients. A decrease in respiratory rate, heart rate and an improvment in oxigenation and ventilation were related in all patients. Only four patients (4/145) died. However, the majority of the studies did not have control group what it disabled an analysis of the causal relation enters the non invasive ventilation in study and the outcomes evaluated. CONCLUSIONS:Because the reduced number of randomizaded clinical trials, the current data suggest that the non invasive ventilation is still an experimental therapy for children with acute respiratory failure
53

Análise dos critérios para ajuste do suporte ventilatório da ventilação mecânica / Analysis of criteria for ventilatory support adjustment of mechanical ventilation

Renata Pletsch Assunção 22 November 2016 (has links)
Introdução: A assistência ventilatória adequada é imprescindível para o tratamento do paciente ventilado artificialmente. A busca por parâmetros para realizar o ajuste ótimo e que tenham aplicação fácil a beira leito como, por exemplo, métodos não-invasivos, são desejáveis. Objetivo: analisar a acurácia diagnóstica das variáveis do padrão respiratório, da P0.1 esofágica e traqueal, para o ajuste da assistência ventilatória em pressão de suporte. Métodos: Vinte e sete pacientes internados em unidade de terapia intensiva foram consecutivamente incluídos no estudo. Todos pacientes estavam no modo de pressão de suporte, que foi aumentada para 20 cmH2O e diminui em passos de 3 cmH2O, até 2 cmH2O ou antes se o paciente apresentasse sinais de desconforto respiratório. Os pacientes foram monitorizados com cateteres para medidas de pressão esofágica e gástrica, com uma peça proximal ao tubo para mensurar a pressão traqueal a partir da oclusão da via aérea e com um pneumotacógrafo para medidas de fluxo. Durante todos níveis de suporte, foram gravados os dados dos cateteres esofágicos, gástricos, da traquéia, dados hemodinâmicos e do padrão respiratório. O ajuste da assistência ventilatória foi classificado como adequado, insuficiente e excessivo de acordo com critérios pré-estabelecidos. Resultados: Foram analisados 210 períodos com diferentes pressões de suporte e em 49% destes períodos a assistência foi excessiva, enquanto em 3,8% a assistência foi insuficiente. No início do estudo, enquanto os pacientes ainda estavam com a assistência ventilatória ajustada pela equipe assistente, 48,2% apresentavam assistência ventilatória excessiva. Pela pequena incidência de períodos com assistência ventilatória insuficiente, não foi avaliado a acurácia das variáveis para diagnóstico de assistência insuficiente. Para diagnosticar assistência ventilatória excessiva, a variável do padrão respiratório que se mostrou mais acurada foi a frequência respiratória, com sensibilidade de 90% e especificidade de 88% quando a frequência respiratória foi menor que 17 incursões por minuto. Outras variáveis do padrão respiratório não mostraram elevada acurácia. Também para o diagnóstico de assistência excessiva, foi elevada a acurácia da P0.1 esofágica (sensibilidade de 81% e especificidade de 70% quando P0.1 <= 1,9) e da P0.1 traqueal (sensibilidade de 81% e especificidade de 70% quando P0.1 <= 2,1). Conclusão: A ocorrência de assistência ventilatória excessiva foi significativamente maior que a assistência ventilatória insuficiente. A frequência respiratória menor que 17 foi a variável do padrão respiratório com maior acurácia para diagnosticar assistência ventilatória excessiva. As P0.1 esofágica e traqueal também tiveram acurácia elevas, mas menores que a frequência respiratória . / Introdution: The adequate assistance is essential for the treatment of mechanically ventilated patient. The search of parameters to achieve the optimal adjustment and with easy application to bedside, for example, non-invasive methods. Objective: Analyze the diagnostic accuracy of the breathing pattern variables, esophageal and tracheal P0.1 for adjustment of mechanical ventilation in pressure support ventilation. Methods: Twenty-seven patients in intensive care unit were consecutively included in the study. All patients were in the pressure support mode, which was raised to 20 cmH2O and decreased in steps of 3 cmH2O up to 2 cmH2O or earlier if the patient had signs of respiratory distress. Patients were monitored with catheters for esophageal and gastric pressure measurements, with the T-piece was used close to the tube to measure tracheal pressure during an airway occlusion and a pneumotachograph for flow measurements. Data was recorded for all support levels to esophageal, gastric, and tracheal pressures, also hemodynamic data and ventilatory pattern. The adjustment of mechanical ventilation was classified as adequate assistance, overassistance and underassistance according to pre-established criteria. Results: Two hundred and ten periods were analyzed with different pressures of support and 49% of these periods were overassistance, while 3,8% these periods were underassistance. At baseline, while patients were still ventilatory assistance set by assistance staff, 48,2% had overassistance. Due to the low incidence of periods with underassistance, the variables accurancy has not been evaluated. The variable breathing pattern that was more accurate diagnosing overassistance was the respiratory rate (90% sensitivity and specificity of 88 % when the respiratory rate was less than 17 breaths per minute). Other variables of the breathing pattern did not show high accuracy although esophageal P0.1 (sensitivity 81 % and specificity of 70 % when P0.1 <= 1,9) and tracheal P0.1 (sensitivity 81 % and specificity of 70 % when P0.1 <= 2,1) were high accuracy diagnosing overassistance. Conclusion: The occurrence of overassistance was significantly higher than underassistance. The respiratory rate below 17 was the variable breathing pattern more accurate to predict overassistance. The esophageal and tracheal P0.1 also had high accuracy but lower than the respiratory rate
54

Ventilação mecânica não-invasiva em crianças com insuficiência respiratória aguda: uma revisão sistemática da literatura / Non invasive ventilation for children with acute respiratory failure: a systematic rewiew

Gonzaga, Carolina Silva 12 December 2007 (has links)
INTRODUÇÃO: A ventilação não-invasiva consiste na aplicação de pressão positiva na via aérea do paciente através de máscaras e interfaces sem a utilização de uma cânula intratraqueal. A presença da cânula na traquéia e outros fatores relacionados à ventilação invasiva convencional são responsáveis por diversas complicações. O uso da ventilação não-invasiva e o desenvolvimento de estudos sobre o tema têm aumentado nos últimos anos, com o objetivo de prevenir ou amenizar as complicações da ventilação invasiva. Em grupos selecionados de pacientes adultos, a ventilação nãoinvasiva é responsável pela diminuição da necessidade de intubação, mortalidade e custos hospitalares. Em pediatria, o número de estudos ainda é reduzido. OBJETIVOS: 1) Descrever os aspectos gerais relacionados ao uso da ventilação não-invasiva (interfaces, ventiladores, modos, pressões, tempo de uso e cuidados) em crianças e adolescentes com insuficiência respiratória aguda. 2) Avaliar a eficácia e a efetividade do uso da ventilação não-invasiva em crianças e adolescentes com insuficiência respiratória aguda. 3) Descrever as complicações da ventilação não-invasiva em crianças e adolescentes com insuficiência respiratória aguda. METODOLOGIA: Foi realizada uma revisão sistemática da literatura nas seguintes bases de dados: Medline, Lilacs, Embase e Colaboração Cochrane, no período de 1966 a maio de 2006, utilizando os seguintes termos: ventilação não-invasiva, CPAP, BIPAP, falha respiratória aguda, hipoxemia e hipercapnia. Os desfechos analisados incluíam: necessidade de intubação, mortalidade, efeitos sobre a oxigenação e ventilação. RESULTADOS: Das 120 publicações encontradas, 11 foram incluídas nesta revisão, sendo um ensaio clínico randomizado, uma revisão sistemática e nove séries de casos, envolvendo um total de 145 pacientes. A ventilação não-invasiva acarretou melhora clínica, e gasométrica dos pacientes. Apenas quatro, dos cento e quarenta e cinco pacientes, morreram. A maioria dos estudos, porém, não tinha grupo controle, o que impossibilitou uma análise da relação causal entre a ventilação não-invasiva em estudo e os efeitos encontrados. CONCLUSÕES: Devido ao reduzido número de ensaios clínicos randomizados, os dados mais atuais sugerem que a ventilação não-invasiva é ainda uma terapia experimental para crianças com IRtA / INTRODUCTION: The non invasive ventilation consists of the application of positive pressure in the airway of the patient through masks and interfaces without the use of a traqueal cannula. The presence of the cannula in the trachea and other factors related to the conventional invasive ventilation is responsible for diverse complications. The use of the non invasive ventilation and the development of studies on the subject have increased in the last years, with the objective to prevent and to brighten up the complications of the invasive ventilation. In selected groups of adult patients use of non invasive ventilation provides effective respiratory support while avoiding the need for endotracheal intubation and mortality decrease. OBJECTIVES: 1) Describe the general aspects related to the use of the non invasive ventilation (interfaces, fans, ways, pressures, time of use and cares) in children and adolescents with acute respiratory insufficience. 2) Avaliar the efficacy and the effectiveness of the use of the non invasive ventilation in children and adolescents with acute respiratory insufficience. 3) Describe the complications of the non invasive ventilation in children and adolescents with acute respiratory insufficience. METHODOLOGY: The medology consisted of a systematic review of literature on non invasive ventilation. The research was performed using: Medline, Lilacs, Embase and Cochrane Collaboration in the period of 1966 to the May of 2006, using the following terms: non invasive ventilation, CPAP, BIPAP, acute respiratory failure, hipoxemia and hipercapnia. The outcomes evaluted were: necessity of endotracheal intubation, mortality, effect on the oxygenation and ventilation. RESULTS: Of the 120 publications founded, 11 were to analyse the eficacy of the non invasive ventilation in the treatment of acute respiratory failure in pediatric patients. Of the 11 clinical trials, one was systematic review, one was randomized clinical trial and six were case series, involving a total of 145 patients. A decrease in respiratory rate, heart rate and an improvment in oxigenation and ventilation were related in all patients. Only four patients (4/145) died. However, the majority of the studies did not have control group what it disabled an analysis of the causal relation enters the non invasive ventilation in study and the outcomes evaluated. CONCLUSIONS:Because the reduced number of randomizaded clinical trials, the current data suggest that the non invasive ventilation is still an experimental therapy for children with acute respiratory failure
55

Avaliação do consumo de oxigênio e do gasto energético durante o teste de respiração espontânea / Evaluation of oxygen consumption and resting energy expenditure during spontaneous breathing test

Alessandra Fabiane Lago 08 December 2014 (has links)
Introdução: O desmame ventilatório é definido como o processo de liberação do suporte ventilatório e como avaliação dessa fase é conduzido o Teste de Respiração Espontânea (TRE). Um dos mais utilizados modos de TRE é a Pressão Positiva Contínua em Vias Aéreas (CPAP), a qual se aplica uma pressão positiva contínua tanto na inspiração quanto na expiração. Contudo, junto com os modos ventilatórios pode ser utilizado a Compensação Automática do Tubo (ATC) cujo objetivo é compensar a resistência imposta pelo tubo endotraqueal. Objetivos: O principal objetivo deste estudo foi comparar o Consumo de Oxigênio (VO2) a o Gasto Energético (GE) pela calorimetria indireta (CI) durante o TRE em CPAP com e sem a ATC. Métodos: O estudo foi randomizado, controlado tipo cross-over com quarenta pacientes em nove leitos de um Centro de Terapia Intensiva de um hospital terciário universitário (Hospital das Clínicas de Ribeirão Preto Universidade de São Paulo, Brasil). Os participantes foram alocados aleatoriamente no grupo 1, no qual era iniciado o TRE em CPAP em uso da ATC e posteriormente em CPAP sem o uso da ATC, ou no grupo 2, no qual era iniciado o TRE em CPAP sem a ATC e em seguida CPAP com a utilização da ATC. Resultados: Cinco pacientes foram excluídos depois da randomização por falha durante o TRE. Dos trinta e cinco restantes a maioria foi do sexo masculino (51%). A média de idade foi de 61,4 ± 16,1 anos. A diferença de VO2 entre os TREs com ATC e sem ATC foi de -1,6 mL.Kg-1.min-1; p=0,23 e intervalo de confiança de 95%: (-4,36; 1,07). Em relação ao GE a diferença foi de -5,4 kcal/d-1; p=0,5 e intervalo de confiança de 95%: (-21,67; 10,79) durante a comparação dos TREs em CPAP com e sem ATC. Conclusão: Não foram observadas diferenças quando se comparou os valores relacionados ao VO2 e GE durante o TRE com e sem ATC. / Introduction: Weaning from mechanical ventilation is defined as the process of release of ventilatory support and how the evaluation of this phase is conducted in the spontaneous breathing test (SBT). One of the most used modes of SBT is the Continuous Positive Airway Pressure (CPAP)which applies a continuous positive pressure in both inspiration and expiration. However, together with the mechanical ventilation modes it can be used the Automatic Tube Compensation (ATC) which compensates the resistance imposed by the endotracheal tube. Objectives: The main goal of this study was to compare the Oxygen Consumption (VO2) and Resting Energy Expenditure (REE) by indirect calorimetry (IC) during the SBT in CPAP with and without ATC. Methods: The study was a prospective randomized, controlled crossover trial, that enrolled 40 patients, in a 9-bed Intensive Care Unit of a tertiary University Hospital. (Clinics Hospital of Ribeirão Preto Medical School, University of São Paulo, Brazil). Participants were randomly allocated in Group 1, in which it was started the SBT in CPAP with ATC and later on CPAP without ATC, or in Group 2, which was started the SBT on CPAP without ATC and then CPAP with ATC.Results: Five patients were excluded after randomization for failure of the SBT. The thirty-five remaining patients were most male (51%). The mean age of the sample was 61.4 ± 16.1 years. The difference of VO2 between the SBT with ATC and no ATC obtained a value of -1.6 mL.Kg-1.min-1; p = 0.23 and 95% confidence interval: (-4.36; 1.07). To analyze the difference of REE between the SBT with ATC and no ATC, it was obtained an estimated value of -5.4 kcal/d-1, p = 0.5 and 95% and confidence interval (-21.67; 10.79). Conclusions: There were no differences in the comparison of VO2 and REE during the SBT with and without ATC.
56

Comparação entre os modos Neurally Adjusted Ventilatory Assist e Ventilação com Pressão de Suporte como ventilação protetora em pacientes com síndrome do desconforto respiratório agudo / Comparison between Neurally Adjusted Ventilatory Assist and Pressure Support Ventilation to deliver protective ventilation in patients with acute respiratory distress syndrome

Silva, Fabia Diniz 29 March 2017 (has links)
Introdução: A ventilação mecânica protetora, que consiste na utilização de volumes correntes iguais ou menores do que 6 ml/kg de peso ideal e pressão de platô abaixo de 30 cmH2O, é recomendada para pacientes com Síndrome do Desconforto Respiratório Agudo (SDRA). Esta estratégia geralmente necessita de ventilação controlada e sedação. Neurally Adjusted Ventilatory Assist (NAVA) ou Pressão de Suporte (PSV), que são modos ventilatórios de assistência parcial, poderiam ser alternativas para oferecer ventilação protetora, mas nesses modos o volume corrente (VC) varia em proporção ao esforço do paciente e não sabemos se é possível manter ventilação protetora. Objetivo: Comparar o VC, padrão respiratório e sincronia paciente-ventilador no modo NAVA com o modo PSV em pacientes com SDRA. Métodos: Realizamos um estudo clínico randomizado cruzado comparando NAVA e PSV em pacientes com SDRA admitidos nas UTIs participantes (NCT01519258). Os pacientes foram ventilados com NAVA e PSV por 15 minutos cada, em ordem aleatória. O suporte inspiratório em NAVA e PSV foram titulados antes da randomização para gerar VC de 4-6ml/kg, enquanto outros parâmetros ventilatórios incluindo PEEP (pressão positiva ao final da expiração) e FIO2 (fração inspirada de oxigênio) foram mantidos constantes. Fluxo, pressão de pico (Ppico) e atividade elétrica do diafragma (AEdi) foram capturados do ventilador usando Servo Tracker (Maquet, Suécia), e os ciclos foram processados com MatLab (Mathworks, EUA), que automaticamente detectava esforços inspiratórios e calculava frequência respiratória (FR) e VC. A detecção de eventos de assincronia foi baseada na análise das curvas do ventilador. Utilizamos teste-t pareado para comparar NAVA e PSV, e valores de p < 0,05 foram considerados significativos. Resultados: 20 pacientes foram incluídos e 14 pacientes completaram o estudo. O VC ficou em níveis protetores, 5,8 ± 1,1 em NAVA e 5,6±1,0 em PSV, p = 0,455. Não houve diferença entre FR (24 ± 7 e 23 ± 7) e AEdi [10,8 (6,3-16,1) e 10,1 (6,7-12,8)] comparando NAVA e PSV, respectivamente. A Ppico foi maior em NAVA (21 ± 3) do que em PSV (19 ± 3), p= 0,001, porém permaneceu em níveis protetores. A pressão parcial de oxigênio (PaO2) foi maior em NAVA [88 (69-96)] do que em PSV [80 (66-96)], p = 0,045 e a relação PaO2/FIO2 foi maior em NAVA [241 (203-265)] em comparação com PSV [236 (144-260)], p = 0,050. O atraso de disparo foi mais comum na PSV [21% (15-51)] do que no NAVA [3% (0,3-14)] (p = 0,002). O duplo disparo foi mais observado em NAVA do que em PSV (p = 0,105) e esforços ineficazes foram incomuns e similares nos dois modos (p = 0,371). A mediana do Índice de Assincronia foi de 33% (20-66%) no PSV e 13% (5-27%) no NAVA (p= 0,0003). Conclusão: Durante a ventilação mecânica protetora, NAVA e PSV apresentaram padrão respiratório semelhante, mas NAVA melhorou a troca gasosa e reduziu a assincronia paciente-ventilador em relação ao PSV. Em pacientes com SDRA que apresentam esforços inspiratórios, NAVA pode ser uma alternativa para oferecer ventilação mecânica protetora / Rationale: Protective mechanical ventilation, which consists of the use of tidal volumes equal or less than 6 ml/kg of predicted body weight and plateau pressure below 30 cmH2O, is recommended for patients with Acute Respiratory Distress Syndrome (ARDS). But it usually requires controlled ventilation and sedation. Using Neurally Adjusted Ventilatory Assist (NAVA) or Pressure Support Ventilation (PSV), which are partial ventilatory modes, could be an alternative to offer protective ventilation, but in these modes tidal volume (Vt) varies in proportion to patient effort and we don´t know if it is possible to maintain protective ventilation. Objective: To compare Vt, respiratory pattern and patient-ventilator asynchrony in NAVA with PSV in patients with ARDS. Methods: We conducted a randomized crossover clinical trial comparing NAVA and PSV in patients with ARDS admitted to ICUs (NCT01519258). Patients were ventilated with NAVA and PSV for 15 minutes each, in random order. Inspiratory support in NAVA and PSV were titrated prior to randomization to deliver Vt of 4-6mL/Kg, while other respiratory parameters including PEEP (positive end-expiratory pressure) and FIO2 (fraction of inspired oxygen) were kept constant. Flow, Peak airway pressure (Paw) and electrical activity of the diaphragm (EAdi) were captured from the ventilator using Servo Tracker (Maquet, Sweden), and cycles were processed with MatLab (Mathworks, USA), which automatically detected inspiratory efforts and calculated respiratory rate (RR) and Vt. Dectection of asynchrony events was based on analysis of the ventilator curves. We used paired t-test to compare NAVA and PSV, and p values <0.05 were considered significant. Results: 20 patients were included and 14 patients completed the study. Tidal volume was kept within protective levels, 5.8 ± 1.1 in NAVA and 5.6 ± 1.0 in PSV, p = 0.455. There was no difference in the RR (24 ± 7 and 23 ± 7) and EAdi [10.8 (6.3-16.1) and 10.1 (6.7-12.8)] comparing NAVA and PSV, respectively. Paw was higher in NAVA (21 ± 3) than in PSV (19 ± 3), p = 0.001, but remained in protective levels. The partial pressure of oxygen (PaO2) was higher in NAVA [88 (69-96)] than in PSV [80 (66-96)], p = 0.045 and PaO2/FIO2 ratio was higher in NAVA [241 (203 -265)] compared to PSV [236 (144-260)], p = 0.050. Trigger delay was more common in PSV [21% (15-51)] than in NAVA [3% (0.3-14)] (p=0.020). Double triggering was observed more frequently in NAVA than in PSV (p=0.105) and ineffective efforts were uncommon and similar in both modes (p=0.371). The median of the Asynchrony Index was 33% (20-66%) in PSV and 13% (5-27%) in NAVA (p = 0.0003). Conclusion: During protective mechanical ventilation, NAVA and PSV presented similar respiratory pattern, while NAVA improved gas exchange and reduced patient-ventilator asynchrony in relation to PSV. In patients with ARDS with inspiratory efforts, NAVA may be an alternative to provide protective mechanical ventilation
57

Ventilação mecânica não invasiva com pressão positiva em vias aéreas, em pacientes HIV/AIDS com lesão pulmonar aguda e insuficiência respiratória: estudo de avaliação do melhor valor de PEEP / Noninvasive ventilation with positive airway pressure in HIV/AIDS patients with acute lung injury and respiratory failure: study to assess the best level of PEEP

Anjos, Carlos Frederico Dantas 06 October 2011 (has links)
INTRODUÇÃO: A síndrome da imunodeficiência adquirida (AIDS) é atualmente uma pandemia, e as doenças pulmonares são a principal causa de morbidade e mortalidade dos pacientes com AIDS. Nesse sentido, as infecções respiratórias são frequente causa de hipoxemia e morte. Os pacientes com AIDS e insuficiência respiratória hipoxêmica frequentemente necessitam de ventilação mecânica invasiva, a qual é independentemente associada com mortalidade. A ventilação não invasiva com pressão positiva refere-se à oferta de assistência ventilatória mecânica sem a necessidade de invasão artificial das vias aéreas, sendo reconhecida por melhorar a oxigenação e a dispneia dos pacientes com insuficiência respiratória hipoxêmica, principalmente se aplicada de forma sequencial e progressiva, e esta pode reduzir a necessidade de ventilação mecânica invasiva nestes pacientes. Tendo em vista as incertezas quanto à resposta da oxigenação a PEEP nos pacientes com AIDS com insuficiência respiratória aguda hipoxêmica e usando o racional da pressurização progressiva das vias aéreas e seu potencial benefício na oxigenação sanguínea, nós fizemos a hipótese de que o incremento sequencial dos níveis de PEEP até 15 cmH2O pode melhorar a oxigenação sanguínea sem afetar o conforto e a hemodinâmica do paciente. O objetivo principal deste estudo foi investigar os efeitos de diferentes sequências de níveis de PEEP aplicado de forma não invasiva sobre as trocas gasosas, a sensação de dispneia e os padrões hemodinâmicos em pacientes com AIDS e insuficiência respiratória aguda hipoxêmica. O objetivo secundário foi avaliar o tempo livre de ventilação mecânica invasiva em 28 dias e a mortalidade hospitalar em 60 dias. MÉTODOS: Foram estudados 30 pacientes adultos com HIV/AIDS e insuficiência respiratória aguda hipoxêmica. Todos os pacientes receberam uma sequência randomizada de PEEP não invasivo (os valores usados foram 5, 10 ou 15 cmH2O) por vinte minutos. A PEEP foi fornecida através de máscara facial com pressão suporte (PSV) de 5 cmH2O e uma FiO2 = 1. Um período de washout de 20 minutos com respiração espontânea foi permitido entre cada PEEP. Variáveis clínicas e uma gasometria arterial foram registradas após cada etapa de PEEP. RESULTADOS: Analisando os 30 pacientes, a oxigenação melhorou linearmente com a elevação da PEEP, contudo, estudando os pacientes conforme a PEEP inicial randomizada, a oxigenação foi similar independentemente da primeira PEEP randomizada (5, 10 ou 15 cmH2O), e somente o subgrupo com PEEP inicial = 5 cmH2O melhorou mais a oxigenação quando PEEPs maiores foram usadas. A PaCO2 também aumentou junto com a elevação da PEEP, especialmente com uma PEEP = 15 cmH2O. O uso de PSV = 5 cmH2O foi associado com significante e consistente melhora da sensação subjetiva de dispnéia e da frequência respiratória com PEEP de 0 a 15 cmH2O. CONCLUSÕES: Os pacientes com SIDA e insuficiência respiratória hipoxêmica melhoram a oxigenação com a elevação progressiva e sequencial da PEEP até 15 cmH2O, contudo a elevação da PaCO2 limita a PEEP até 10 cmH2O. Uma PSV = 5 cmH2O promove uma melhora da sensação subjetiva da dispnéia independentemente do uso de PEEP / INTRODUTION: The acquired immunodeficiency syndrome (AIDS) is a pandemic, and lung diseases are the leading cause of morbidity and mortality and are often associated with respiratory infections, hypoxemia and death. The noninvasive ventilation with positive pressure refers to the provision of mechanical ventilatory assistance without the need for artificial airway invasion, being recognized for improving oxygenation and dyspnea in patients with hipoxemic respiratory failure. Patients with AIDS and hypoxemic respiratory failure often require invasive mechanical ventilation, which is independently associated with mortality. Given the uncertainties about response in oxygenation with PEEP in patients with AIDS with acute hypoxemic respiratory failure and using the rational for progressive pressurization of the airway and its potential benefits on blood oxygenation, we made the hypothesis that increased levels of sequential PEEP up to 15 cmH2O may improve blood oxygenation without affecting the comfort and hemodynamics of the patient. The main objective of this study was to investigate the effects of different sequences of PEEP levels on gas exchange, the sensation of dyspnea and hemodynamics in patients with AIDS and acute hypoxemic respiratory failure. The secondary objective was to assess the time free of invasive mechanical ventilation in 28 days and hospital mortality within 60 days. METHODS: We studied 30 adults patients with HIV/AIDS and acute hypoxemic respiratory failure. All patients received a randomized sequence of noninvasive PEEP (the values used were 5,10 or 15 cmH2O) for twenty minutes. PEEP was delivered via face mask with pressure support (PSV) of 5 cmH2O and FiO2 = 1. A washout period of 20 minutes with spontaneous breathing was allowed between each PEEP trial. Clinical variables and arterial blood gases were recorded after each PEEP step. RESULTS: Analyzing the 30 patients, oxygenation improved linearly with increasing PEEP, however studying the patients randomized according to the initial PEEP, oxygenation was similar regardless of the first randomized PEEP (5,10 or 15 cmH2O), and only the subgroup with initial PEEP = 5 cmH2O further improve the oxygenation when high PEEP were used. The PaCO2 also rose beside the PEEP elevation, especially with a PEEP = 15 cmH2O. The use of PSV = 5 cmH2O was associated with significant and consistent improvement of subjective sensation of dyspnea and respiratory rate with a PEEP from 0 to 15 cmH2O. CONCLUSION: AIDS-patients with hypoxemic respiratory failure improve oxygenation with a progressive sequential elevation of PEEP up to 15 cmH2O, however the elevation of PaCO2 limit the PEEP up to 10 cmH2O. A PSV = 5 cmH2O promotes an improvement of subjective sensation of dyspnea independently from the use of PEEP
58

Comparação entre os modos Neurally Adjusted Ventilatory Assist e Ventilação com Pressão de Suporte como ventilação protetora em pacientes com síndrome do desconforto respiratório agudo / Comparison between Neurally Adjusted Ventilatory Assist and Pressure Support Ventilation to deliver protective ventilation in patients with acute respiratory distress syndrome

Fabia Diniz Silva 29 March 2017 (has links)
Introdução: A ventilação mecânica protetora, que consiste na utilização de volumes correntes iguais ou menores do que 6 ml/kg de peso ideal e pressão de platô abaixo de 30 cmH2O, é recomendada para pacientes com Síndrome do Desconforto Respiratório Agudo (SDRA). Esta estratégia geralmente necessita de ventilação controlada e sedação. Neurally Adjusted Ventilatory Assist (NAVA) ou Pressão de Suporte (PSV), que são modos ventilatórios de assistência parcial, poderiam ser alternativas para oferecer ventilação protetora, mas nesses modos o volume corrente (VC) varia em proporção ao esforço do paciente e não sabemos se é possível manter ventilação protetora. Objetivo: Comparar o VC, padrão respiratório e sincronia paciente-ventilador no modo NAVA com o modo PSV em pacientes com SDRA. Métodos: Realizamos um estudo clínico randomizado cruzado comparando NAVA e PSV em pacientes com SDRA admitidos nas UTIs participantes (NCT01519258). Os pacientes foram ventilados com NAVA e PSV por 15 minutos cada, em ordem aleatória. O suporte inspiratório em NAVA e PSV foram titulados antes da randomização para gerar VC de 4-6ml/kg, enquanto outros parâmetros ventilatórios incluindo PEEP (pressão positiva ao final da expiração) e FIO2 (fração inspirada de oxigênio) foram mantidos constantes. Fluxo, pressão de pico (Ppico) e atividade elétrica do diafragma (AEdi) foram capturados do ventilador usando Servo Tracker (Maquet, Suécia), e os ciclos foram processados com MatLab (Mathworks, EUA), que automaticamente detectava esforços inspiratórios e calculava frequência respiratória (FR) e VC. A detecção de eventos de assincronia foi baseada na análise das curvas do ventilador. Utilizamos teste-t pareado para comparar NAVA e PSV, e valores de p < 0,05 foram considerados significativos. Resultados: 20 pacientes foram incluídos e 14 pacientes completaram o estudo. O VC ficou em níveis protetores, 5,8 ± 1,1 em NAVA e 5,6±1,0 em PSV, p = 0,455. Não houve diferença entre FR (24 ± 7 e 23 ± 7) e AEdi [10,8 (6,3-16,1) e 10,1 (6,7-12,8)] comparando NAVA e PSV, respectivamente. A Ppico foi maior em NAVA (21 ± 3) do que em PSV (19 ± 3), p= 0,001, porém permaneceu em níveis protetores. A pressão parcial de oxigênio (PaO2) foi maior em NAVA [88 (69-96)] do que em PSV [80 (66-96)], p = 0,045 e a relação PaO2/FIO2 foi maior em NAVA [241 (203-265)] em comparação com PSV [236 (144-260)], p = 0,050. O atraso de disparo foi mais comum na PSV [21% (15-51)] do que no NAVA [3% (0,3-14)] (p = 0,002). O duplo disparo foi mais observado em NAVA do que em PSV (p = 0,105) e esforços ineficazes foram incomuns e similares nos dois modos (p = 0,371). A mediana do Índice de Assincronia foi de 33% (20-66%) no PSV e 13% (5-27%) no NAVA (p= 0,0003). Conclusão: Durante a ventilação mecânica protetora, NAVA e PSV apresentaram padrão respiratório semelhante, mas NAVA melhorou a troca gasosa e reduziu a assincronia paciente-ventilador em relação ao PSV. Em pacientes com SDRA que apresentam esforços inspiratórios, NAVA pode ser uma alternativa para oferecer ventilação mecânica protetora / Rationale: Protective mechanical ventilation, which consists of the use of tidal volumes equal or less than 6 ml/kg of predicted body weight and plateau pressure below 30 cmH2O, is recommended for patients with Acute Respiratory Distress Syndrome (ARDS). But it usually requires controlled ventilation and sedation. Using Neurally Adjusted Ventilatory Assist (NAVA) or Pressure Support Ventilation (PSV), which are partial ventilatory modes, could be an alternative to offer protective ventilation, but in these modes tidal volume (Vt) varies in proportion to patient effort and we don´t know if it is possible to maintain protective ventilation. Objective: To compare Vt, respiratory pattern and patient-ventilator asynchrony in NAVA with PSV in patients with ARDS. Methods: We conducted a randomized crossover clinical trial comparing NAVA and PSV in patients with ARDS admitted to ICUs (NCT01519258). Patients were ventilated with NAVA and PSV for 15 minutes each, in random order. Inspiratory support in NAVA and PSV were titrated prior to randomization to deliver Vt of 4-6mL/Kg, while other respiratory parameters including PEEP (positive end-expiratory pressure) and FIO2 (fraction of inspired oxygen) were kept constant. Flow, Peak airway pressure (Paw) and electrical activity of the diaphragm (EAdi) were captured from the ventilator using Servo Tracker (Maquet, Sweden), and cycles were processed with MatLab (Mathworks, USA), which automatically detected inspiratory efforts and calculated respiratory rate (RR) and Vt. Dectection of asynchrony events was based on analysis of the ventilator curves. We used paired t-test to compare NAVA and PSV, and p values <0.05 were considered significant. Results: 20 patients were included and 14 patients completed the study. Tidal volume was kept within protective levels, 5.8 ± 1.1 in NAVA and 5.6 ± 1.0 in PSV, p = 0.455. There was no difference in the RR (24 ± 7 and 23 ± 7) and EAdi [10.8 (6.3-16.1) and 10.1 (6.7-12.8)] comparing NAVA and PSV, respectively. Paw was higher in NAVA (21 ± 3) than in PSV (19 ± 3), p = 0.001, but remained in protective levels. The partial pressure of oxygen (PaO2) was higher in NAVA [88 (69-96)] than in PSV [80 (66-96)], p = 0.045 and PaO2/FIO2 ratio was higher in NAVA [241 (203 -265)] compared to PSV [236 (144-260)], p = 0.050. Trigger delay was more common in PSV [21% (15-51)] than in NAVA [3% (0.3-14)] (p=0.020). Double triggering was observed more frequently in NAVA than in PSV (p=0.105) and ineffective efforts were uncommon and similar in both modes (p=0.371). The median of the Asynchrony Index was 33% (20-66%) in PSV and 13% (5-27%) in NAVA (p = 0.0003). Conclusion: During protective mechanical ventilation, NAVA and PSV presented similar respiratory pattern, while NAVA improved gas exchange and reduced patient-ventilator asynchrony in relation to PSV. In patients with ARDS with inspiratory efforts, NAVA may be an alternative to provide protective mechanical ventilation
59

Titulação da PEEP rápida versus lenta guiadas por tomografia de impedância elétrica em pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca: estudo clínico randomizado / Fast versus slow PEEP trial guided by electrical impedance tomography in hypoxemic patients following cardiac surgery: randomized controlled trial

Nakamura, Maria Aparecida Miyuki 04 April 2018 (has links)
OBJETIVO: avaliar a concordância entre duas titulações decrementais de PEEP guiadas por tomografia de impedância elétrica (TIE): uma rápida, com tempo total inferior a 7 minutos, e uma lenta, com 40 minutos, e comparar os efeitos hemodinâmicos causados pelas duas titulações; e como objetivo secundário, comparar os efeitos fisiológicos da PEEP ótima escolhida pela TIE com a PEEP escolhida pela tabela PEEP-FiO2 do ARDSNet, durante 4 horas de ventilação mecânica. MÉTODOS: Trata-se de um estudo clínico, randomizado, unicêntrico que incluiu pacientes hipoxêmicos no pós-operatório imediato de cirurgia cardíaca. Os pacientes foram randomizados em 3 grupos: Titulação Rápida, Titulação Lenta ou Controle (tabela PEEP-FiO2 do ARDSNet). Os grupos Titulação Rápida e Titulação Lenta foram submetidos a duas titulações de PEEP guiadas pela TIE (uma rápida e uma lenta) precedidas de manobra de recrutamento alveolar. A titulação da PEEP foi realizada da PEEP de 23 cmH2O até a PEEP de 5 cmH2O, em passos decrementais de 2 cmH2O, com duas durações: 40 segundos na Titulação Rápida ( < 7 minutos no total), ou 4 minutos na Titulação Lenta (40 minutos no total). A PEEP ótima (PEEPTIT) foi definida como a menor PEEP com menos de 5% de colapso estimado pela TIE. No grupo Controle, a PEEP foi ajustada de acordo com a oxigenação, baseada no protocolo ARDSNet. Todos os pacientes permaneceram em ventilação mecânica por 4 horas com a PEEP de acordo com seu grupo, e foram monitorados com TIE durante todo estudo. A comparação entre as manobras de Titulação Rápida e Lenta incluiu as seguintes variáveis: colapso recrutável e hiperdistensão estimados pela TIE, valor da PEEPTIT, menor pressão arterial média e dose de noradrenalina durante as titulações. A comparação com o grupo controle incluiu: nível de PEEP, complacência do sistema respiratório, driving pressure, colapso e hiperdistensão estimados pela TIE (associação entre o ZMIN - que representa a aeração - e a Complacência Z avaliados regionalmente), e oxigenação (PaO2/FiO2) ao longo das 4 horas de acompanhamento. RESULTADOS: Não houve diferença entre colapso e hiperdistensão estimados pela Titulação Rápida e Lenta, nem nos valores de PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0,13). A pressão arterial média foi maior durante a titulação rápida (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0,035) e não houve diferença no uso de noradrenalina. A PEEPTIT pela TIE foi significativamente mais alta do que a PEEP do Grupo Controle. Os grupos Titulação Rápida e Lenta apresentaram comportamentos semelhantes após ajuste da PEEPTIT, e houve aumento significativo na complacência do sistema respiratório no primeiro minuto, que permaneceu maior que a condição basal ao final das 4 horas (T. Lenta: 0,73 ± 0,2 vs 0,89 ± 0,1 mL/cmH2O/Kg do peso predito, P < 0,001; T. Rápida: 0,7 ± 0,1 vs 0,85 ± 0,2 mL/cmH2O/Kg do peso predito, P < 0,001); com a melhora da complacência houve redução da driving pressure e, ao final das 4 horas, esta permaneceu menor que no tempo basal. No grupo controle, a complacência não mudou durante as 4 horas de ventilação mecânica (0,63 ± 0,1 vs 0,58 ± 0,1 mL/cmH2O/Kg do peso predito, P=0,34) e a driving pressure aumentou significativamente. A oxigenação melhorou nos três grupos, mas foi mais alta nos grupos PEEPTIT guiados pela TIE. Após ajuste da PEEPTIT, em ambos os grupos (Titulação Rápida e Lenta) houve aumento da aeração nas regiões dependente e não dependente, recrutamento na região dependente e não houve hiperdistensão na região não dependente, mesmo com a PEEP mais alta. No grupo controle, de acordo com a tabela PEEP-FiO2, a necessidade de PEEP diminuiu ao longo do tempo (6,1 ± 1,4 cmH2O no tempo 4 horas), causando redução da aeração. CONCLUSÕES: Houve concordância entre titulações rápida e lenta guiadas pela TIE em relação à PEEPTIT, estimativa de colapso e hiperdistensão para cada passo de PEEP; a titulação rápida da PEEP pôde ser realizada com menor repercussão hemodinâmica quando comparada com a titulação convencional lenta. A PEEP individualizada pela TIE melhorou a complacência, reduziu a driving pressure e melhorou a oxigenação, sem causar hiperdistensão quando comparada com protocolo ARDSNet. Descritores: respiração com pressão positiva; mecânica respiratória; impedância elétrica; tomografia; procedimentos cirúrgicos cardíacos; respiração artificial; insuficiência respiratória; tomografia de impedância elétrica / OBJECTIVE: to assess the agreement of \"optimum-PEEP\" values selected by two decremental PEEP trials guided by electrical impedance tomography (EIT): a Fast one lasting less than 7 minutes, and a Slow one lasting 40 minutes, and to compare the hemodynamic effects caused by these two trials; as secondary objectives, we aimed at comparing the physiological effects of the optimum-PEEP chosen by EIT (Fast or Slow) with those chosen by ARDSNet PEEP-FiO2 table during the subsequent 4 hours of mechanical ventilation. METHODS: in this single center, randomized controlled trial, hypoxemic patients immediately after cardiac surgery were randomized into three groups: Fast Titration (FAST-EIT), Slow Titration (SLOW-EIT) and Control (ARDSNet PEEP-FiO2 table). After recruiting maneuvers, and starting from a PEEP of 23 cmH2O, the FAST-EIT and SLOW-EIT groups were submitted to decremental PEEP trials, in steps of 2 cmH2O, until reaching 5 cmH2O, with two different durations: 40 seconds (the entire maneuver lasted < 7 minutes) or 4 minutes (entire maneuver lasted 40 minutes). The optimum-PEEP (PEEPTIT) was defined as the lowest PEEP with less than 5% of collapse estimated by EIT. In the control group, PEEP was adjusted according to oxygenation based on ARDSNet protocol. All patients were ventilated for 4 hours with PEEP according to their randomized groups, and all were monitored with EIT during the study. The comparison between Fast and Slow PEEP trials included: recruitable collapse and hyperdistension estimated by EIT, level of optimum PEEP, lowest mean arterial pressure and norepinephrine doses during the trials. The comparison with the control group included: level of PEEP, compliance and driving pressure, collapse (aeration) and hyperdistension estimated with EIT, and oxygenation (PaO2/FiO2) during 4 hours of mechanical ventilation. RESULTS: There was no difference between recruitable collapse and hyperdistension estimated by EIT between Fast and Slow maneuvers, as well as for the PEEPTIT (13 ± 4 vs 14 ± 4 cmH2O, P=0.13). Mean arterial pressure was higher during the Fast maneuver in comparison to the Slow maneuver (92mmHg [IQ25-75%: 81-111] vs 83mmHg [71-93], P=0.035), without differences in norepinephrine. FAST-EIT and SLOW-EIT groups presented similar changes during the time: after set PEEPTIT there was an immediate and significant improvement in respiratory-system compliance, which remained above baseline condition during the 4 hours of mechanical ventilation (SLOW-EIT: from 0.73 ± 0.2 to 0.89 ± 0.1 mL/cmH2O/Kg of PBW, P < 0.001; FAST-EIT: from 0.7 ± 0.1 to 0.85 ± 0.2 mL/cmH2O/Kg of PBW, P < 0.001); as respiratory compliance improved, driving pressure significantly reduced and remained lower than the baseline condition after 4 hours. In the control group, respiratory compliance did not change between baseline and 4 hours (from 0.63 ± 0.1 to 0.58 ± 0.1 mL/cmH2O/Kg of PBW, P=0.34) but driving pressure significantly increased as PEEP decreased. Oxygenation improved in all groups, but it was higher in the EIT groups. After setting PEEPTIT in both EIT groups (Fast or Slow), there was an increase in aeration in both, nondependent and dependent regions. In contrast, regional compliance increased in the dependent region and didn\'t change in nondependent region, suggesting that the strategy caused long-lasting recruitment of dependent regions and did not produced hyperdistension of non-dependent lung. In the control group, the required PEEP, adjusted by ARDSNet PEEP-FiO2 table, decreased along the time, causing evident collapse in EIT derived signals. CONCLUSION: There was no difference between recruitable collapse and hyperdistension estimated by EIT and PEEPTIT between Fast and Slow maneuvers; Fast PEEP trial guided by EIT could be performed in less than 7 minutes, with less hemodynamic consequences than the traditional Slow maneuver. Individualized PEEP guided by EIT improved respiratory compliance, reduced driving pressure and improved oxygenation without causing hyperdistension - when compared to a PEEP set according the ARDSNet protocol
60

Utilização da nova definição de Berlim no diagnóstico da síndrome do desconforto respiratório agudo em crianças criticamente doentes / Utilization of the new Berlin definition for the diagnosis of acute respiratory distress dyndrome in critically ill children

Eliane Roseli Barreira 20 March 2018 (has links)
INTRODUÇÃO: Em 1994, a Conferência de Consenso Americano-Europeu estabeleceu pela primeira vez critérios diagnósticos para definir a Síndrome do Desconforto Respiratório Agudo, critérios estes utilizados desde então em adultos e crianças. Em 2012, uma nova definição - a chamada definição de Berlim - foi proposta para adultos, porém sem referências quanto à sua aplicabilidade na faixa etária pediátrica. O objetivo deste estudo foi avaliar a prevalência, os desfechos e os fatores associados à ocorrência de Síndrome do Desconforto Respiratório Agudo em crianças, utilizando a definição de Berlim, em comparação à definição da Conferência de Consenso Americano-Europeu. MÉTODOS: Estudo de coorte prospectivo, multicêntrico, realizado entre março e setembro de 2013 em oito Unidades de Terapia Intensiva Pediátrica no estado de São Paulo. Todas as crianças de 1 mês a 15 anos admitidas nos centros participantes foram consideradas elegíveis e avaliadas diariamente quanto à presença de Síndrome do Desconforto Respiratório Agudo, de acordo com as definições da Conferência de Consenso Americano-Europeu e de Berlim, com os respectivos desfechos. RESULTADOS: Dentre os 562 pacientes admitidos no estudo, 58 (10,3%) e 57 (10%) pacientes desenvolveram Síndrome do Desconforto Respiratório Agudo, de acordo com as definições da Conferência de Consenso Americano-Europeu e de Berlim, respectivamente. Dentre os pacientes diagnosticados, conforme a definição de Berlim, nove (16%) tiveram Síndrome do Desconforto Respiratório Agudo leve, 21 (37%) moderada e 27 (47%) grave. Em comparação com pacientes que não desenvolveram a síndrome, pacientes com Síndrome do Desconforto Respiratório Agudo tiveram maior número de comorbidades, maiores escores de gravidade à admissão, maior tempo de internação hospitalar, maior duração de ventilação mecânica e maior mortalidade (p < 0,05). As comparações de desfechos entre as três categorias de gravidade de acordo com a definição de Berlim mostraram diferenças significativas no número de dias livres de ventilação mecânica (21, 20 e 5 dias, p < 0,001) e de mortalidade (0, 15% e 41%, p=0,02) entre pacientes com Síndrome do Desconforto Respiratório Agudo leve, moderada e grave, respectivamente. Estas diferenças foram observadas apenas para pacientes com Síndrome do Desconforto Respiratório Agudo grave em relação aos outros dois grupos. Não foram observadas diferenças no tempo de internação em UTI e tempo de internação hospitalar entre as três categorias de gravidade. CONCLUSÕES: A definição de Berlim é capaz de identificar um subgrupo de pacientes com piores desfechos, conforme demonstrado pelo menor número de dias livres de ventilação mecânica e maior mortalidade em crianças com Síndrome do Desconforto Respiratório Agudo grave / INTRODUCTION: In 1994, the American-European Consensus Conference first established the diagnostic criteria to define Acute Respiratory Distress Syndrome. Since then, these criteria have been used to define the syndrome in both adults and children. In 2012, a new definition - the so-called Berlin definition - was proposed to be used in adults, but no references were made regarding its applicability in children. The objective of this study was to evaluate the prevalence, outcomes and risk factors associated with the development of Acute Respiratory Distress Syndrome in children according to the Berlin definition as compared with the American-European Consensus Conference definition. METHODS: A prospective, multicenter cohort study conducted from March to September 2013 at eight Pediatric Intensive Care Units located at the state of Sao Paulo. All children aged 1 month to 15 years old who met eligibility criteria were evaluated daily for the presence of Acute Respiratory Distress Syndrome according to the American-European Consensus Conference and the Berlin definitions, and related outcomes. RESULTS: Of the 562 patients included, Acute Respiratory Distress Syndrome developed in 58 (10.3%) and 57 (10%) patients, according to the American-European Consensus Conference and the Berlin definitions, respectively. Among patients diagnosed according to the Berlin definition, 9 (16%) were classified as mild, 21 (37%) moderate, and 27 (47%) severe. Patients with Acute Respiratory Distress Syndrome had a significantly higher number of comorbidities, higher severity scores at admission, longer hospital length of stay, longer duration of mechanical ventilation and higher mortality (p < 0.05) than patients who did not develop the syndrome. Comparisons across the three severity categories according to the Berlin definition showed significant differences in the number of ventilator-free days (21, 20 and 5 days, p < 0.001) and mortality (0.15% and 41%, p < 0.02) for patients with mild, moderate and severe Acute Respiratory Distress Syndrome, respectively. Differences were observed only for patients with severe Acute Respiratory Distress Syndrome compared with the two other severity groups. No differences in Pediatric Intensive Care or hospital length of stay were observed across the three categories. CONCLUSIONS: The Berlin definition can identify a subgroup of patients with distinctly worse outcomes, as shown by the reduced number of ventilator-free days and higher mortality for children with severe Acute Respiratory Distress Syndrome

Page generated in 0.0607 seconds