• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • Tagged with
  • 21
  • 14
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Valores normativos de força isocinética dos extensores do joelho em mulheres idosas

Pereira, Juscélia Cristina 22 August 2018 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação em Educação Física, 2018. / OBJETIVOS: Fornecer valores normativos da força isocinética dos extensores do joelho em mulheres idosas e verificar a implicação funcional da classificação proposta. Além disso, desenvolver e validar uma equação para a predição de valores de referência da força isocinética. MÉTODOS: Foi avaliado um total de 500 mulheres idosas com idade entre 60 e 84 anos (67,51 ± 5,70 anos). A força dos extensores do joelho foi avaliada pelo pico de torque (PT) isocinético absoluto e relativo à massa corporal, utilizando o dinamômetro isocinético Biodex System na velocidade de 60°/s. O desempenho funcional foi avaliado pelo teste de sentar e levantar cinco vezes (Five Times Sit to Stand- FTSTS) e Timed Up & Go (TUG). As participantes foram categorizadas em cinco faixas etárias (60-64; 65-69; 70-74; 75-79; 80-84), e os percentis 20, 40, 60 e 80 foram identificados e empregados como pontos de corte para fins de classificação da força isocinética. A comparação do desempenho funcional entre os níveis de classificação foi efetuada por meio dos testes ANOVA one-way e Qui-quadrado. Adicionalmente, foi investigada a acurácia das equações de Neder et al. (1999) e Gross et al. (1989). A equação de referência, proposta pelo presente estudo, foi desenvolvida por meio de regressão linear múltipla do tipo backward. Para as comparações das médias do PT mensurados com os preditos pelas equações de referência, foi utilizado o teste t-Student pareado. O percentual do predito foi calculado para cada equação (PT medido / PT de referência * 100). Foi ainda utilizado o método de Bland-Altman, para avaliar a concordância entre os valores observados e esperados, de acordo com as equações de referência. RESULTADOS: Como esperado, a força isocinética dos extensores do joelho diminui significativamente com o avanço da idade. Idosas classificadas nos estratos inferiores de força isocinética exibiram desempenho reduzido nos testes funcionais (p<0,05). As equações de Neder et al. (1999) e Gross et al. (1989) superestimaram significativamente os valores de PT (ambos p<0,001) e apresentaram viés médio de 6,79 Nm e 6,75 Nm, respectivamente. Relativamente a essas equações, a equação desenvolvida pelo presente estudo PT (Nm): 39,72- [1,24 x idade (anos)] + [0,44 x massa corporal (kg)] + [69,70 x estatura (m)] apresentou erro médio significativamente menor (aproximadamente 40%). CONCLUSÕES: O desempenho funcional se mostrou reduzido entre as idosas classificadas nos estratos inferiores de força do quadríceps, indicando potencial aplicação desses valores em ambientes clínicos e de pesquisa. Além disso, as equações de referência (Neder et al. e Gross et al.) não são adequadas para mulheres idosas; a equação desenvolvida no presente estudo apresentou erro médio consideravelmente menor e, portanto, com valores de referência mais adequados. / OBJECTIVES: To provide normative values of knee extensors isokinetic strength for older women and verify the functional implication of the proposed classification. We also aimed at developing and validating an equation to individually predict reference values of isokinetic strength. METHODS: A total of 500 women with age ranging from 60 to 84 years (67.51± 5.70 years) took part in this project. Knee extensors strength was measured using an isokinetic dynamometer (Biodex system) at the speed of 60º/s; peak torque (PT) was expressed in absolute values and relative to body weight. The Timed Up and Go and the 5 times Sit-to-Stand test were used for functional performance evaluation. Participants were categorized into age groups of five years range (60-64, 65-69, 70-74, 75-79, 80-84) and the 20th, 40th, 60th, and 80th percentiles were used as cutting points to classify the isokinetic strength. We used the one-way ANOVA and Chi-Square tests to compare the functional performance between the classification levels. Additionally, the accuracy of the equations developed by Neder et al. (1999) and Gross et al. (1989) were investigated. The reference equation was developed using backward multiple linear regression. Paired Student’s t test was used to compare measured PT with those predicted by the reference equations. The percentage of the predicted was calculated for each equation (measured PT/reference PT*100). The Bland-Altman method evaluated the agreement between the values observed and expected according to the reference equations. RESULTS: As expected, the knee extensors isokinetic strength significantly decreased with age. Volunteers classified in the lower isokinetic strength strata showed reduced performance in the functional tests (both p<0.05). The equations described by Neder et al. (1999) and Gross et al. (1989) significantly overestimated measured PT values (both p<0.001), with mean bias of 6.79 Nm and 6.75 Nm, respectively. Regarding these equations, the equation developed in this study PT (Nm): 39.72 – [1.24 x age (years)] + [0.44 x body mass (kg)] + [69.70 x stature (m)] presented significantly lower mean error (approximately 40%). CONCLUSIONS: Reduced physical function was observed among individuals classified in the lower percentile groups, indicating a potential application in preventive and therapeutic settings. Furthermore, available reference equations (Neder et al. and Gross et al.) are not suitable for older women; the equation developed in the present study provided considerably lower average error and thus with more suitable reference values in this population.
2

Sensibilidade da avaliação isocinética do quadril à mudança dos parâmetros de realização do exame / Sensitivity of the isokinetic evaluation of the hip to the change in the parameters of the examination

Santana, Tiago Silva 10 April 2017 (has links)
Postula-se que a alteração do eixo do dinamômetro isocinético influencie os resultados da avaliação isocinética da articulação do quadril, todavia essa afirmação não foi testada experimentalmente. O objetivo desta pesquisa foi quantificar a influência da mudança dos parâmetros de avaliação isocinética na articulação do quadril em sujeitos saudáveis. Este é um estudo tipo transversal com 32 quadris de indivíduos saudáveis. Inicialmente, foi realizada avaliação isocinética para flexo-extensão e adução-abdução do quadril com o eixo do dinamômetro alinhado com o trocânter maior para ambos os movimentos. A seguir, a avaliação foi repetida com o eixo posicionado 3 centímetros cranial para a avaliação de flexo-extensão e na interseção da linha formada entre a espinha ilíaca póstero-superior e o centro da linha poplítea e a linha formada entre os trocânteres. Cada avaliação foi realizada em 5 repetições nas velocidades de 60°/s e 180°/s. Houve diferença estatisticamente significante dos parâmetros de avaliação isocinética com a mudança da posição dos eixos para o trabalho muscular no movimento de flexão do quadril na velocidade de 60°/s. Para o movimento de extensão, apenas a variável pico de torque em 60°/s não apresentou diferença estatística significante. No movimento de abdução, as variáveis pico de torque e potência apresentaram diferença significante em ambas as velocidades. Para o movimento de adução, a variável pico de torque e trabalho apresentaram diferença significante em ambas as velocidades. A magnitude da diferença do trabalho muscular foi maior que 6% em todos os movimentos, exceto para flexão a 180°/s e abdução a 60°/s Conclui-se que a mudança do eixo de movimentação do quadril de fato impõe modificações sensíveis nos resultados de pico de torque, trabalho e potência do exame isocinético do quadril em diferentes velocidades angulares e posições. / It is postulated that the change in the isokinetic dynamometer axis influences the results of the isokinetic evaluation of the hip joint, but this assertion has not been experimentally tested. The objective of this research was to quantify the influence of the change of the isokinetic evaluation parameters on the hip joint in healthy subjects. This is a cross-sectional study with 32 hips of healthy individuals. Initially, an isokinetic evaluation was performed for flexion-extension and adduction-abduction of the hip with the dynamometer axis aligned with the greater trochanter for both movements. Next, the evaluation was repeated with the cranial axis positioned for flexion-extension evaluation and at the intersection of the line formed between the posterior-superior iliac spine and the center of the popliteal line and the line formed between the trochanters. Each evaluation was performed in 5 repetitions at speeds of 60°/s and 180°/s. There was a statistically significant difference of the isokinetic evaluation parameters with the change of the position of the axis for the muscular work in the movement of hip flexion at the speed of 60°/s. For the extension movement, only the peak torque variable at 60°/s did not present a significant statistical difference. In the abduction movement, the peak torque and power variables showed a significant difference in both velocities. For the adduction movement, the peak torque and work variable presented significant difference at both speeds. The magnitude of the muscle work difference was greater than 6% in all movements, except for 180°/s flexion and 60°/s abduction. It is concluded that the change in the axis of hip movement does impose sensible changes in the results of peak torque, work and power in hip isokinetic examination at different angular velocities and positions.
3

Avaliação volumétrica e funcional do músculo glúteo máximo submetido a gluteoplastia de aumento com implantes de silicone / Volumetric and functional evaluation of the gluteus maximus muscle after augmentation gluteoplasty using silicone implants

Fernando Serra Guimarães 20 August 2014 (has links)
A operação para aumento de glúteos com implantes teve início no fim da década de 1960, entretanto a técnica intramuscular, considerada padrão atualmente, foi descrita cerca de 30 anos depois. Cirurgiões e pacientes apresentam crescente interesse na realização do aumento de glúteos haja vista que sua frequência apresenta aumento nos últimos anos. A utilização de implantes intramusculares que superam o volume do músculo em mais de cinquenta por cento configura uma situação nova que deve ser estudada. O tecido muscular estriado esquelético apresenta grande suscetibilidade para atrofia secundariamente à compressão, e sendo o glúteo máximo um músculo importante na manutenção da postura ereta, deambulação, corrida e salto, é necessário pesquisar possíveis alterações musculares decorrentes da operação. O objetivo deste estudo é avaliar o volume e força do músculo glúteo máximo ao longo de 12 meses após a introdução de implantes intramusculares, o posicionamento destes implantes no interior da musculatura e mudanças antropométricas obtidas com a operação. Foram selecionadas 48 mulheres, 24 candidatas a gluteoplastia de aumento com implantes compuseram o grupo de estudo e 24 candidatas a mamoplastia de aumento compuseram o grupo controle de acordo com os critérios de inclusão e exclusão. As pacientes foram avaliadas em quatro momentos diferentes: pré-operatório e após três, seis e 12 meses da operação. Em todas as etapas foi realizada avaliação clínica nutricional, tomografia computadorizada com reconstrução 3D e teste isocinético. Todas as pacientes permaneceram afastadas de atividades físicas durante três meses após a operação. Foram utilizados implantes glúteos em gel coesivo de base oval e superfície lisa com volumes de 350 cm3 e 400 cm3. O nível de significância estatística foi mantido em 5%. As pacientes candidatas a gluteoplastia apresentaram valores da relação entre as medidas da cintura e do quadril maiores que aquelas do grupo controle. A operação de aumento glúteo com implantes demonstrou eficácia na melhora desta relação. Os implantes apresentaram posição obliqua com inclinação semelhante à das fibras musculares após três meses da operação, independente da posição em que foram inseridos. As pacientes do grupo de estudo apresentaram atrofia muscular após 12 meses em 6,14% à esquerda e 6,43% à direita, as pacientes do grupo controle não apresentaram atrofia. A força muscular apresentou redução do valor de torque máximo durante a flexão do quadril a 30 /s em ambos os grupos e aumento do torque máximo durante a adução a 60 /s apenas no grupo de estudo. Concluímos que a introdução de implante de silicone no interior do músculo glúteo máximo causa atrofia muscular após 12 meses. As variações na força deste músculo nesse período não podem ser atribuídas primariamente à operação ou à presença dos implantes em seu interior. Os implantes permaneceram em posição obliqua. O aumento de glúteos com implantes gera mudanças antropométricas nas mulheres submetidas a esta operação. / The gluteal augmentation surgery using implants began in the late 1960s, however intramuscular technique, which is considered standard today, was described about 30 years later. Plastic surgeons and patients have increased interest in gluteal augmentation given the fact that the operation has been more frequently in recent years. The use of intramuscular implants that overcomes the muscle volume in more than fifty percent configures a new situation that should be studied. The skeletal muscle tissue shows high susceptibility to atrophy secondary to compression, and the gluteus maximus is an important muscle in the maintenance of erect posture, walking, running and jumping, it is necessary to investigate possible muscle changes resulting from the operation. The objective of this study is to assess the volume and strength of the gluteus maximus muscle during 12 months after the introduction of the implants, the position of these implants within the muscles and anthropometric changes obtained with the operation. 48 women were selected, 24 candidates for gluteal augmentation composed the study group and 24 candidates for breast augmentation composed the control group according to the criteria of inclusion and exclusion. The patients were evaluated at four different moments: pre-operatively and after three, six and 12 months of the operation. At all stages of the study, was carried out nutritional evaluation, CT with 3D reconstruction and isokinetic testing. All patients remained away from physical activities for three months after the operation. Cohesive gel, oval base and smooth surface gluteal implants were used with volumes of 350 cm3 and 400 cm3. The level of statistical significance was 5%. The patients who were candidates for gluteoplasty presented bigger waist to hip ratio than those of the control group. The operation of gluteal augmentation using implants has shown to be effective in improving this ratio. The implants showed similar oblique position of the muscle fibers after three months of operation, regardless of the position in which they were placed. The patients in the study group had muscle atrophy after 12 months, 6.14% 6.43% left and right, the control patients showed no atrophy. Muscle strength decreased the maximum torque during hip flexion at 30 /s in both groups and increased maximum torque during the adduction at 60 /s only in the study group. We conclude that the introduction of silicone implant within the gluteus maximus muscle causes muscle atrophy after 12 months. Variations in the strength of this muscle during this period cannot be attributed primarily to the operation or the presence of implants. The implants remained in oblique position. The gluteal augmentation surgery generates anthropometric changes in women who have undergone this operation.
4

Efeitos de um programa de fisioterapia aquática em mulheres com osteoporose

Nonato, Guilherme de Paula Marinho 30 June 2010 (has links)
Made available in DSpace on 2016-06-02T20:19:14Z (GMT). No. of bitstreams: 1 3234.pdf: 645016 bytes, checksum: 9479adc52c79a01657c8e46490bb2ca7 (MD5) Previous issue date: 2010-06-30 / Universidade Federal de Sao Carlos / Osteoporosis has been considered the most common metabolic disease, affecting about one third of postmenopausal women, accounting for a high rate of morbidity and mortality. This study was to evaluate the effects of a treatment program for aquatic therapy of muscle performance and balance in women with osteoporosis. We selected 40 volunteers, with a densitometric diagnosis of osteoporosis at the beginning and end of treatment, the volunteers underwent a physical therapy evaluation consisting of anamnesis, evaluation of peak torque and work normalized by body mass and power isometric and isokinetic 60 ° / sea 120 ° / s knee and ankle muscles in the dominant (D) and nondominant (ND) with five repetitions, with concentric contractions performed on the isokinetic dynamometer Biodex Multi-Joint System 2. The postural control was assessed by questionnaire Berg, the Time Up and Go test (TUG) and the force platform BERTEC. After the initial assessment, a researcher who was not part of the research generated through computer, a randomization list and placed one by one, in opaque envelopes, which were not translucent sealed. Participants were selected consecutively through the withdrawal of the envelope, and assigned to two groups: control group (CG) and intervention group (IG). The treatment was performed twice a week with one hour for 12 weeks in therapy pool. It is noteworthy that the GC has received the same treatment of the GI, after 12 weeks. Normality was tested using the Shapiro-Wilk test. For comparison of, we used the nonparametric Mann-Whitney test to compare results before and after physical therapy, we used the nonparametric Wilcoxon test. For the evaluation of qualitative data was used chi-square test. It was adopted a significance level of 5% (p &#8804; 0.05). In isokinetic knee with a speed of 60 ° / s, there was a significant improvement in the IM variable peak torque normalized by body mass during flexion and extension of member D and ND, the work variable normalized by body mass significant improvement in member D in flexion and in extension of GI, and variable muscle power, no significant improvement in GI and GC. When evaluated the knee joint with a speed of 120 ° / s, significant improvement was observed in all variables of GI and CG no significant improvement and work in variable proportion to body weight not only significant improvement in knee extension of GI ND . In the evaluation of ankle at the speed 60 ° / s, variable work normalized by body mass and muscle power was a significant improvement in all variables of GI. For the evaluation of balance, significant improvement was found for the questionnaire Berg, TUG and some variables of the force platform IM This training program was effective for improving muscle strength in some muscle groups important for maintaining the standing posture and activities of everyday life, thus reducing the risk of falls. / A osteoporose vem sendo considerada a doença metabólica mais comum, atingindo cerca de um terço das mulheres na pós-menopausa, sendo responsável por um alto índice de morbidade e mortalidade. O objetivo deste estudo foi avaliar os efeitos de um programa de tratamento de fisioterapia aquática sobre o desempenho muscular e equilíbrio de mulheres com osteoporose. Foram selecionadas 40 voluntárias, com diagnóstico densitométrico de osteoporose; ao inicio e término do tratamento as voluntárias foram submetidas a uma avaliação fisioterapêutica composta por uma anamnese, avaliação do pico de torque e trabalho normalizado pela massa corpórea e potência isométrica e isocinética a 60°/s e a 120°/s da musculatura do joelho e tornozelo no membro dominante (D) e não dominante (ND) com 5 repetições, com contrações concêntricas realizadas no dinamômetro isocinético Biodex Multi-Joint System 2. O controle postural foi avaliado pelo questionário de Berg, pelo teste Time up and Go (TUG) e com a plataforma de força Bertec. Após a avaliação inicial, um pesquisador que não participou da pesquisa gerou, por meio de computador, uma lista de randomização e a colocou, uma a uma, em envelopes opacos, não translúcidos que foram selados. Os participantes foram sorteados de forma consecutiva, por meio, da retirada do envelope, e alocados em dois grupos: Grupo controle (GC) e Grupo intervenção (GI). O tratamento foi realizado duas vezes por semana, com uma hora de duração, durante 12 semanas em piscina terapêutica. Cabe ressaltar que o GC recebeu o mesmo tratamento do GI, após as 12 semanas. A normalidade foi testada por meio do Teste de Shapiro-Wilk. Para a comparação entre os grupos, foi utilizado o teste não paramétrico Mann-Whitney, para comparação dos resultados antes e após o tratamento fisioterapêutico utilizou-se o teste não paramétrico de Wilcoxon. Para a avaliação dos dados qualitativos foi utilizado o teste Qui-Quadrado. Foi adotado um nível de significância de 5% (p&#8804;0,05). Na avaliação isocinética de joelho com velocidade de 60°/s houve uma melhora significativa do GI na variável pico de torque normalizado pela massa corpórea durante a flexão e extensão do membro D e ND , na variável trabalho normalizado pela massa corpórea houve melhora significativa no membro D tanto na flexão quanto na extensão do GI, e na variável potência muscular, não houve melhora significativa GI e GC. Quando avaliada a articulação do joelho com velocidade de 120°/s, foi observado melhora significativa em todas as variáveis do GI e o GC não houve melhora significativa e na variável trabalho proporcional ao peso corporal só não houve melhora significativa na extensão do joelho ND do GI. Na avaliação de tornozelo na velocidade 60°/s, na variável trabalho normalizado pela massa corpórea e potência muscular ocorreu um melhora significativa em todas as variáveis do GI. Para a avaliação do equilíbrio, a melhora significativa foi encontrada para o questionário de Berg, TUG e algumas variáveis da plataforma de força do GI Este programa de treinamento mostrou-se efetivo para melhora da força muscular de alguns grupos musculares importantes para manutenção da postura ortostática e atividades do dia a dia, diminuindo assim o risco de quedas.
5

Avaliação volumétrica e funcional do músculo glúteo máximo submetido a gluteoplastia de aumento com implantes de silicone / Volumetric and functional evaluation of the gluteus maximus muscle after augmentation gluteoplasty using silicone implants

Fernando Serra Guimarães 20 August 2014 (has links)
A operação para aumento de glúteos com implantes teve início no fim da década de 1960, entretanto a técnica intramuscular, considerada padrão atualmente, foi descrita cerca de 30 anos depois. Cirurgiões e pacientes apresentam crescente interesse na realização do aumento de glúteos haja vista que sua frequência apresenta aumento nos últimos anos. A utilização de implantes intramusculares que superam o volume do músculo em mais de cinquenta por cento configura uma situação nova que deve ser estudada. O tecido muscular estriado esquelético apresenta grande suscetibilidade para atrofia secundariamente à compressão, e sendo o glúteo máximo um músculo importante na manutenção da postura ereta, deambulação, corrida e salto, é necessário pesquisar possíveis alterações musculares decorrentes da operação. O objetivo deste estudo é avaliar o volume e força do músculo glúteo máximo ao longo de 12 meses após a introdução de implantes intramusculares, o posicionamento destes implantes no interior da musculatura e mudanças antropométricas obtidas com a operação. Foram selecionadas 48 mulheres, 24 candidatas a gluteoplastia de aumento com implantes compuseram o grupo de estudo e 24 candidatas a mamoplastia de aumento compuseram o grupo controle de acordo com os critérios de inclusão e exclusão. As pacientes foram avaliadas em quatro momentos diferentes: pré-operatório e após três, seis e 12 meses da operação. Em todas as etapas foi realizada avaliação clínica nutricional, tomografia computadorizada com reconstrução 3D e teste isocinético. Todas as pacientes permaneceram afastadas de atividades físicas durante três meses após a operação. Foram utilizados implantes glúteos em gel coesivo de base oval e superfície lisa com volumes de 350 cm3 e 400 cm3. O nível de significância estatística foi mantido em 5%. As pacientes candidatas a gluteoplastia apresentaram valores da relação entre as medidas da cintura e do quadril maiores que aquelas do grupo controle. A operação de aumento glúteo com implantes demonstrou eficácia na melhora desta relação. Os implantes apresentaram posição obliqua com inclinação semelhante à das fibras musculares após três meses da operação, independente da posição em que foram inseridos. As pacientes do grupo de estudo apresentaram atrofia muscular após 12 meses em 6,14% à esquerda e 6,43% à direita, as pacientes do grupo controle não apresentaram atrofia. A força muscular apresentou redução do valor de torque máximo durante a flexão do quadril a 30 /s em ambos os grupos e aumento do torque máximo durante a adução a 60 /s apenas no grupo de estudo. Concluímos que a introdução de implante de silicone no interior do músculo glúteo máximo causa atrofia muscular após 12 meses. As variações na força deste músculo nesse período não podem ser atribuídas primariamente à operação ou à presença dos implantes em seu interior. Os implantes permaneceram em posição obliqua. O aumento de glúteos com implantes gera mudanças antropométricas nas mulheres submetidas a esta operação. / The gluteal augmentation surgery using implants began in the late 1960s, however intramuscular technique, which is considered standard today, was described about 30 years later. Plastic surgeons and patients have increased interest in gluteal augmentation given the fact that the operation has been more frequently in recent years. The use of intramuscular implants that overcomes the muscle volume in more than fifty percent configures a new situation that should be studied. The skeletal muscle tissue shows high susceptibility to atrophy secondary to compression, and the gluteus maximus is an important muscle in the maintenance of erect posture, walking, running and jumping, it is necessary to investigate possible muscle changes resulting from the operation. The objective of this study is to assess the volume and strength of the gluteus maximus muscle during 12 months after the introduction of the implants, the position of these implants within the muscles and anthropometric changes obtained with the operation. 48 women were selected, 24 candidates for gluteal augmentation composed the study group and 24 candidates for breast augmentation composed the control group according to the criteria of inclusion and exclusion. The patients were evaluated at four different moments: pre-operatively and after three, six and 12 months of the operation. At all stages of the study, was carried out nutritional evaluation, CT with 3D reconstruction and isokinetic testing. All patients remained away from physical activities for three months after the operation. Cohesive gel, oval base and smooth surface gluteal implants were used with volumes of 350 cm3 and 400 cm3. The level of statistical significance was 5%. The patients who were candidates for gluteoplasty presented bigger waist to hip ratio than those of the control group. The operation of gluteal augmentation using implants has shown to be effective in improving this ratio. The implants showed similar oblique position of the muscle fibers after three months of operation, regardless of the position in which they were placed. The patients in the study group had muscle atrophy after 12 months, 6.14% 6.43% left and right, the control patients showed no atrophy. Muscle strength decreased the maximum torque during hip flexion at 30 /s in both groups and increased maximum torque during the adduction at 60 /s only in the study group. We conclude that the introduction of silicone implant within the gluteus maximus muscle causes muscle atrophy after 12 months. Variations in the strength of this muscle during this period cannot be attributed primarily to the operation or the presence of implants. The implants remained in oblique position. The gluteal augmentation surgery generates anthropometric changes in women who have undergone this operation.
6

Sensibilidade da avaliação isocinética do quadril à mudança dos parâmetros de realização do exame / Sensitivity of the isokinetic evaluation of the hip to the change in the parameters of the examination

Tiago Silva Santana 10 April 2017 (has links)
Postula-se que a alteração do eixo do dinamômetro isocinético influencie os resultados da avaliação isocinética da articulação do quadril, todavia essa afirmação não foi testada experimentalmente. O objetivo desta pesquisa foi quantificar a influência da mudança dos parâmetros de avaliação isocinética na articulação do quadril em sujeitos saudáveis. Este é um estudo tipo transversal com 32 quadris de indivíduos saudáveis. Inicialmente, foi realizada avaliação isocinética para flexo-extensão e adução-abdução do quadril com o eixo do dinamômetro alinhado com o trocânter maior para ambos os movimentos. A seguir, a avaliação foi repetida com o eixo posicionado 3 centímetros cranial para a avaliação de flexo-extensão e na interseção da linha formada entre a espinha ilíaca póstero-superior e o centro da linha poplítea e a linha formada entre os trocânteres. Cada avaliação foi realizada em 5 repetições nas velocidades de 60°/s e 180°/s. Houve diferença estatisticamente significante dos parâmetros de avaliação isocinética com a mudança da posição dos eixos para o trabalho muscular no movimento de flexão do quadril na velocidade de 60°/s. Para o movimento de extensão, apenas a variável pico de torque em 60°/s não apresentou diferença estatística significante. No movimento de abdução, as variáveis pico de torque e potência apresentaram diferença significante em ambas as velocidades. Para o movimento de adução, a variável pico de torque e trabalho apresentaram diferença significante em ambas as velocidades. A magnitude da diferença do trabalho muscular foi maior que 6% em todos os movimentos, exceto para flexão a 180°/s e abdução a 60°/s Conclui-se que a mudança do eixo de movimentação do quadril de fato impõe modificações sensíveis nos resultados de pico de torque, trabalho e potência do exame isocinético do quadril em diferentes velocidades angulares e posições. / It is postulated that the change in the isokinetic dynamometer axis influences the results of the isokinetic evaluation of the hip joint, but this assertion has not been experimentally tested. The objective of this research was to quantify the influence of the change of the isokinetic evaluation parameters on the hip joint in healthy subjects. This is a cross-sectional study with 32 hips of healthy individuals. Initially, an isokinetic evaluation was performed for flexion-extension and adduction-abduction of the hip with the dynamometer axis aligned with the greater trochanter for both movements. Next, the evaluation was repeated with the cranial axis positioned for flexion-extension evaluation and at the intersection of the line formed between the posterior-superior iliac spine and the center of the popliteal line and the line formed between the trochanters. Each evaluation was performed in 5 repetitions at speeds of 60°/s and 180°/s. There was a statistically significant difference of the isokinetic evaluation parameters with the change of the position of the axis for the muscular work in the movement of hip flexion at the speed of 60°/s. For the extension movement, only the peak torque variable at 60°/s did not present a significant statistical difference. In the abduction movement, the peak torque and power variables showed a significant difference in both velocities. For the adduction movement, the peak torque and work variable presented significant difference at both speeds. The magnitude of the muscle work difference was greater than 6% in all movements, except for 180°/s flexion and 60°/s abduction. It is concluded that the change in the axis of hip movement does impose sensible changes in the results of peak torque, work and power in hip isokinetic examination at different angular velocities and positions.
7

Efeito das sessões de familiarização sobre o pico de torque e taxa de desenvolvimento de torque = comparações entre jovens, meia idade e idosos = Effect of familiarization sessions on peak torque and rate of torque development : comparisons among young, middle age and elderly / Effect of familiarization sessions on peak torque and rate of torque development : comparisons among young, middle age and elderly

Fazolin, Marcio Aparecido Franco de Godoy, 1981- 04 September 2013 (has links)
Orientador: Cláudia Regina Cavaglieri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Física / Made available in DSpace on 2018-08-22T16:14:08Z (GMT). No. of bitstreams: 1 Fazolin_MarcioAparecidoFrancodeGodoy_M.pdf: 1352810 bytes, checksum: bb34bcd02d7a93531f2f4ca3be5a26c0 (MD5) Previous issue date: 2013 / Resumo: A contração muscular isocinética, assim como a isométrica balística, tem sido utilizada para determinar o pico de torque (PT) e a taxa de desenvolvimento de torque (TDT), consideradas importantes variáveis neuromusculares. Sessões de familiarização são necessárias para a verificar a estabilidade das medidas em diferentes protocolos de verificar a estabilidade destas medidas. No entanto, ainda não estão claro quantas sessões de familiarização são necessários para estabilizar tais componentes em diferentes idades. O objetivo deste estudo foi determinar o número de sessões de familiarização necessárias para alcançar a estabilidade da medida no PT e TDT a partir da contração isométrica balística e o PT a partir da contração isocinética nas velocidades 60º/s, 180º/s, 240º/s e 300º/s, nas faixas etárias. Sessenta e quatro sujeitos saudáveis participaram de dois protocolos de familiarização: o isométrico balístico, com 31 sujeitos dividos em jovem (idade de 22,75 ± 4,53 anos), meia-idade (idade de 50,45 ± 6,12 anos) e idosos (idade de 67,80 ± 7,28 anos); e o protocolo isocinético com 33 sujeitos dividos em jovens (idade de 21,92 ± 2,57), meia idade (idade de 47,20 ± 5,18 anos) e idosos (idade de 62,08 ± 3,53 anos). Foram realizadas quatro sessões de testes no dinamômetro isocinético separadas por 72h. De acordo com ANOVA, não foram observadas diferenças estatisticamente significantes entre os grupos e entre as sessões respectivamente (jovens, P = 0,92, P = 0,74; meia idade, P = 0,98, P = 0,99; idoso, P = 0,99, P = 0,69) para o protocolo isométrico balístico. Por outro lado, o protocolo isocinético apresentou uma variabilidade nas sessões de familiarização em relação às velocidades angulares analisadas (60º/s e 240ºs, jovem, P = 0,007 e P = 0,02 e meia idade, P = 0,01 e P = 0,007 e grupo idoso 240º/s e 300ºs, P = 0,02 e P = 0,05). Em conclusão, é possível que o nível de atividade física dos sujeitos e o tipo de protocolo utilizado tenham influenciado nas respostas do presente estudo. Os efeitos emanados do processo de envelhecimento parecem influenciar de forma mais acentuada as respostas do PT em contrações isocinéticas / Abstract: The muscular isokinetic contraction, as well as ballistic isometric, has been used to determine the peak torque (PT) and the rate of torque development (RTD), considered important neuromuscular variables. Familiarization sessions are necessary to verify the stability of neuromuscular measures in different protocols. However, it is unclear yet how many familiarization sessions are needed to stabilize these components at different ages. The aim of this study was to determine the number of familiarization sessions required to reach the stability of measure in the PT and RTD from the ballistic isometric contraction and in the PT from the isokinetic contraction at speeds 60°/s, 180º/s, 240º/s and 300º/s in different groups. Sixty-four healthy subjects participated in two familiarization protocols: the ballistic isometric , with 31 subjects divided in, young (age 22.75 ± 4.53 years), middle-age (age 50.45 ± 6.12 years) and elderly (age 67.80 ± 7.28 years): and isokinetic protocol with 33 subjects divided in young (age 21.92 ± 2.57 years), middle age (age 47.20 ± 5.18 years) and elderly (age 62.08 ± 3.53 years). There were four test sessions in isokinetic dynamometer with 72h apart. According to ANOVA, there were no statistically significant differences among groups and among sessions respectively (young P = 0.92, P = 0.74; middle age, P = 0.98, P = 0.99; elderly, P = 0.99, P = 0.69) for the ballistic isometric protocol In the other hand, the isokinetic protocol showed variability in familiarization sessions related to angular velocities analyzed. The number of familiarization sessions to reach the stabilization of PT was divergent angular in angular velocities. In conclusion, it is possible that the level of physical activity of the subjects and the type of protocol used have influenced on responses of the present study. The effects arisen from the aging process seem influence more sharply the responses of PT in isokinetic contractions / Mestrado / Atividade Fisica Adaptada / Mestre em Educação Física
8

Aplicação de protocolo de 8 semanas de treinamento utilizando Método Pilates : avaliação eletromiográfica da musculatura abdominal e pico de torque no dinamômetro isocinético / Evaluation of eight weeks of Pilates sessions : eletromyographic responses and peak torque of the abdominal muscles

Gavião, Kelly Cristina, 1985- 26 August 2018 (has links)
Orientador: Antonio Carlos de Moraes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Física / Made available in DSpace on 2018-08-26T22:48:29Z (GMT). No. of bitstreams: 1 Gaviao_KellyCristina_M.pdf: 2542214 bytes, checksum: b165bdb8314f9d07e2bdb39460e1f45f (MD5) Previous issue date: 2015 / Resumo: O presente trabalho teve como objetivo verificar a influência de oito semanas de sessões de Método Pilates nas respostas eletromiográficas e pico de torque da musculatura abdominal, em jovens do sexo feminino. Foram selecionadas para o estudo 20 voluntárias universitárias, com idade entre 18 e 25 anos, fisicamente ativas, que foram classificadas, aleatoriamente, em dois grupos: Grupo experimental (GE) e grupo Controle (GC). As voluntárias do grupo experimental foram submetidas a oito semanas de treinamento utilizando exercícios do Método Pilates no solo (MAT Pilates), enquanto as voluntárias do grupo controle não receberam intervenção. Antes e após as oito semanas de treinamento, todas as voluntárias foram submetidas à avaliação isocinética da musculatura abdominal por meio do dinamômetro isocinético da marca BIODEX® e avaliação eletromiográfica da musculatura abdominal utilizando eletrodos (superfície) ativos e o Sistema de Aquisição e Análise de Sinais MP150 da BIOPAC System, contendo 16 canais. Os músculos abdominais foram analisados de forma conjunta e os eletrodos de superfície foram posicionados bilateralmente no ventre dos músculos reto abdominal, fibras superiores e inferiores, e músculos oblíquo externo abdominal. Os dados dos sinais eletromiográficos brutos foram expressos em RMS (root mean square). Os dados obtidos após o treinamento foram comparados com os dados obtidos no período pré-treinamento e aos dados obtidos na avaliação do grupo controle. Os valores referentes ao protocolo realizado no dinamômetro isocinético, expressos em newton metro (Nm), foram baseados no pico de torque de cada voluntária durante a execução do teste. Foi empregada a análise de variância (ANOVA) seguida de post hoc de Tukey. A significância estatística adotada foi de 5% (p < .05). Paras valores referentes ao protocolo de eletromiografia, expressos em root-mean-square (RMS), foi empregada a análise de variância (ANOVA). A significância estatística adotada foi de 5% (p < .05). Foi possível observar que os maiores valores de pico de torque de flexão de tronco foram encontrados nos indivíduos do grupo experimental quando comparados ao grupo controle após a realização do protocolo, porém sem diferença significativa nos valores de pico de torque da extensão de tronco. Para os dados de ativação de fibras musculares, houve aumento significativo na ativação da musculatura abdominal analisada do grupo experimental, após a realização do protocolo e quando comparado ao grupo controle. Em conclusão, o protocolo utilizado teve influência positiva no fortalecimento e ativação de fibras da musculatura abdominal analisada / Abstract: The purpose of this study was to verify the influence of eight weeks of Pilates sessions in electromyographic responses and peak torque of the abdominal muscles in young women. Twenty female university volunteers, aged between 18 and 25 years old, physically active participated in this investigation and were divided randomly into two groups: experimental group (GE) and control group (GC). The volunteers of the experimental group underwent eight weeks of training using the Pilates Method exercises on the ground (MAT Pilates), while the volunteers in the control group received no intervention. Before and after eight weeks of training, all the volunteers were submitted to isokinetic abdominal muscles evaluation using an isokinetic dynamometer (Biodex®), also electromyographic activity of the abdominal muscles using active electrodes (surface) using the Data Acquisition System MP150 (BIOPAC System) with 16 channels. The abdominal muscles were analyzed together. The surface electrodes were placed bilaterally in the rectus abdominis muscles, upper and lower fibers, and obliquus externus muscles. Data from raw electromyographic signals were expressed in RMS (root mean square). The data obtained after training were compared with the data obtained in the pre-training period and also obtained in the evaluation of the control group. The values regarding the protocol performed at the isokinetic dynamometer expressed in newton meters (Nm), were based on peak torque of each volunteer during the test run. Analysis of variance (ANOVA) followed by post hoc Tukey was used. The used statistical significance was 5% (p <.05). For figures on electromyography protocol, expressed in root-mean-square (RMS), we used analysis of variance (ANOVA). The statistical significance used was 5% (p <.05). It was observed that the highest peak values of trunk flexion torque were found in the subjects in the experimental group compared with the control group after the completion of the protocol, but with no significant difference in the peak torque values of trunk extension. For muscle fiber activation data, there was a significant increase activation of the abdominal muscles analyzed in the experimental group after the completion of the protocol and compared to the control group. In conclusion, the protocol used had a positive influence in strengthening and activation of the abdominal muscles analyzed fibers / Mestrado / Biodinamica do Movimento e Esporte / Mestra em Educação Física
9

Análise isocinética dos músculos rotadores do ombro em atletas de basquetebol adaptado e indivíduos sedentários com lesão medular / Isokinetic muscle Analysis shoulder rotators in adapted basketball athletes and sedentary individuals with spinal cord injury

Freitas, Poliane Silva 26 July 2016 (has links)
A articulação do ombro é muito solicitada em indivíduos com lesão medular usuários de cadeira de rodas, seja no deslocamento diário, na propulsão da cadeira de rodas ou na prática paradesportiva. Diante dessa realidade, este estudo teve por objetivo avaliar e comparar o desempenho muscular através do pico de torque corrigido pela a massa corporal, o trabalho e a potência dos grupos musculares do manguito rotador, relacionados aos movimentos de rotação interna e externa dos ombros, em atletas de basquetebol em cadeira de rodas, com trauma raquimedular, comparando-os com indivíduos com trauma raquimedular, sedentários, utilizando como instrumento o dinamômetro isocinético da marca 4 BIODEX®. Foram avaliados 36 indivíduos com trauma raquimedular, com níveis de lesão completa abaixo de T1 e idades entre 18 e 45 anos. Sendo 18 indivíduos atletas de basquetebol em cadeira de rodas e 18 indivíduos cadeirantes sedentários. Os testes isocinéticos foram realizados na posição sentada, com o ombro em 45° de abdução no plano da escápula e 30° de flexão no plano frontal, com amplitude de movimento de 70°, sendo 40° em rotação externa e 30° para rotação interna. O protocolo foi realizado por meio do teste isocinético com cinco repetições para as velocidades de 60°/s e 180°/s, com propósito de avaliar o pico de torque/peso e o trabalho, e 10 repetições em 300°/s para avaliar a potência muscular, em ambos os ombros, com intervalo de 1 minuto, entre as repetições. As comparações entre as variáveis foram analisadas com o teste do quiquadrado ou teste exato de Fisher. Para a análise das diferenças entre as médias das variáveis contínuas, utilizou-se o teste t, com nível de significância de 5%. Como resultado, observou-se semelhança das variáveis antropométrica entre os grupos; o pico de torque/peso, o trabalho e a potência muscular dos rotadores internos e externos de ambos os ombros dos atletas de basquetebol em cadeira de rodas foram significativamente maiores quando comparados com o grupo controle, em todas as velocidades testadas (P <0,001); também foi encontrada uma correlação do ganho de força muscular com o tempo de lesão medular. Conclui-se que os atletas cadeirantes apresentaram maior desempenho muscular em relação aos cadeirantes que não praticavam nenhum tipo de esporte. / The shoulder joint is much, requested in individuals with spinal cord injury wheelchair users, at offset journal, in wheelchair propulsion, as well as in practice to-sports. Facing this reality, the present research aimed to evaluate and compare the performance through muscle peak torque fixed by body mass, the work and the power of the rotator cuff muscle groups, related to the movements of internal and external rotation of the shoulder, in basketball, wheelchair athletes with spinal cord injury, comparing them to individuals with spinal cord injury, sedentary using as an instrument the isokinetic dynamometer 4 BIODEX® brand. 36 individuals were evaluated with spinal cord injury, with complete injury levels below T1 and between the ages of 18 to 45 years. Being 18 individuals athletes of wheelchair basketball and wheelchair accessible, sedentary individuals 18. The isokinetic tests were performed in a sitting position, with the shoulder in 45° of abduction in scapula and 30° of flexion in the frontal plane, with range of motion of 70°, and 40° in external rotation and 30° for internal rotation. The Protocol was carried out through the isokinetic test with 5 reps for 60°/s speeds and 180°/s with purpose to assess the peak torque/weight and work, and 10 repetitions at 300°/s to assess muscle power, in both shoulders, with 1 minute interval between repetitions. The comparisons between the variables were assessed the Chi-square test or Fisher\'s exact test. For the analysis of the differences between the media of the variables keep, used the t test, with a significance level of 5%. As a result, it was observed there similarity between the groups Anthropometric, that the peak torque/weight work and muscle power of internal and external rotators of both shoulders of the athletes of wheelchair basketball was significantly higher when compared with the control group, the tested velocities (P < 0.001) and correlation of muscle strength gain with time of spinal cord injury. It is concluded that the wheelchair athletes has increased muscle performance in relation to wheelchair users who do not practice any kind of sport.
10

Efeitos do envelhecimento e da osteoporose na cifose torácica, na propriocepção e no torque dos músculos do tronco. / v Effects of aging and osteoporosis on thoracic kyphosis, on proprioception and on trunk muscle torque.

Granito, Renata Neves 18 February 2005 (has links)
Made available in DSpace on 2016-06-02T20:19:28Z (GMT). No. of bitstreams: 1 DissRNG.pdf: 2309849 bytes, checksum: 187c8c568d92e6cc123d4d1a8efa1bf3 (MD5) Previous issue date: 2005-02-18 / Universidade Federal de Sao Carlos / The aim of this study was to evaluate the effects of aging and osteoporosis on thoracic kyphosis degree, on extensors and flexors trunk muscles torque and on proprioception. Moreover, this study investigated the possible correlation among the variables studied in this work. It was evaluated 40 voluntary women, divided in four distinct groups: Young Group (10 women) aged between 20 and 30 years old, Adult Group (10 women) aged between 40 and 50 years old, Old Group (10 women) aged more than 60 years old and Osteoporotic Group (10 women) aged the same as the previous group, however with diagnosis of osteoporosis on spine. The volunteers were submitted to a previous interview, to a bone densitometry to quantify the bone mineral density of lumbar spine and to an x-ray of the thoracic spine in lateral view to verify the thoracic kyphosis degree. Moreover, the volunteer were submitted to a proprioception evaluation and to the isokinetic test of the trunk muscles, both performed on the BIODEX SYSTEM 3 equipment. Data were statistically analyzed (p &#8804; 0, 05). The results showed that thoracic kyphosis degree was significantly greater in the Osteoporotic Group, followed by the Old Group, Adult and the Young Group. It was found a significant reduction on the trunk extensor torque imposed by ageing and aggravated by osteoporosis. The ageing process was still responsible for a reduction on the trunk flexor torque, but this condition was not exacerbated by osteoporosis. The extensor torque was greater than the flexor, during both eccentric and concentric contractions, in both velocities of the isokinetic test. However, there were no significant differences between the groups on the extensor and flexor torque relation. The older volunteers, with and without osteoporosis, showed a greater proprioceptive deficit than the younger volunteers. It was found a significant negative correlation between bone mineral density with kyphosis degree and positive correlation between mineral density and trunk extensor torque. The thoracic kyphosis degree showed a negative correlation with the trunk extensor torque and a positive correlation with age and proprioceptive deficit. This study concluded that the physiologic aging process is responsible for an increased thoracic kyphosis, a reduction of the extensor and flexor trunk torques and a reduction of the proprioceptive sensibility. The osteoporosis amplifies the increase in thoracic kyphosis and the reduction on the trunk extensor torque imposed by age. However, the osteoporosis does not have any effect on the aging reduction of flexor torque of trunk muscles and on proprioceptive deficit. / A proposta deste estudo foi verificar os efeitos do envelhecimento e da osteoporose no grau de cifose torácica, no torque extensor e flexor dos músculos do tronco e na propriocepção, além de correlacionar estas variáveis visando verificar a interdependência entre elas. Para isso, foram avaliadas 40 mulheres voluntárias, dispostas em quatro grupos distintos. O Grupo Adultojovem foi composto por 10 mulheres com idade entre 20 e 30 anos, o Grupo Adulto por 10 mulheres dos 40 aos 50 anos de idade, o Grupo Idoso sem Osteoporose foi composto por 10 mulheres com idade superior a 60 anos e, por fim, o Grupo Idoso com Osteoporose incluiu 10 mulheres da mesma faixa etária do grupo anterior, porém com diagnóstico de osteoporose na coluna vertebral. As voluntárias foram submetidas a uma entrevista inicial, ao exame de densitometria óssea, com o intuito de quantificar a massa óssea da coluna vertebral, e a radiografia da coluna torácica em vista lateral, para determinação do grau de cifose torácica. Além disso, as voluntárias foram submetidas ao teste de propriocepção e ao teste isocinético dos músculos do tronco, ambos realizados no equipamento BIODEX SYSTEM 3. Os dados foram analisados estatisticamente (p &#8804; 0,05). Verificou-se que o grau de cifose torácica foi significativamente maior no grupo idoso com osteoporose, seguido pelo grupo idoso sem osteoporose, adulto e, por fim, o grupo adulto-jovem. Os resultados demonstraram também uma diminuição no pico de torque extensor do tronco imposta pelo envelhecimento e agravada pela osteoporose. O envelhecimento também foi responsável por uma diminuição no torque flexor do tronco, no entanto esta condição não foi exacerbada pela osteoporose. O torque extensor foi maior que o flexor, durante tanto as contrações excêntricas como as concêntricas, nas duas velocidades do teste isocinético. Porém, não existiram diferenças significativas entre os grupos na relação entre os torques extensor e flexor do tronco. As voluntárias idosas, com e sem osteoporose, apresentaram um déficit proprioceptivo significativamente maior que as adultasjovens. Houve correlação significativa da densidade mineral óssea da coluna com o grau de cifose torácica (correlação negativa) e com o torque extensor do tronco (correlação positiva). O grau de cifose torácica correlacionou-se, negativamente, com o torque extensor do tronco e, positivamente, com a idade e com o déficit proprioceptivo. O estudo conclui que o envelhecimento fisiológico é responsável por aumento do grau de cifose torácica, diminuição no torque extensor e flexor do tronco e diminuição na sensibilidade proprioceptiva. A osteoporose acentua esse aumento no grau de cifose torácica e o declínio no torque extensor do tronco, porém não agrava a diminuição no torque flexor, nem o deficit proprioceptivo.

Page generated in 0.0384 seconds