Spelling suggestions: "subject:"dvd"" "subject:"bvd""
1 |
A Study on Core Competence of In Vitro Diagnostic Device Industry- A Case of ST CompanyFan, Chien-Chia 06 June 2012 (has links)
Medical examination is the use of modern physical and chemical methods, laboratory technology, medical equipment for clinical diagnosis and treatment, provide a reference. In vitro diagnostic medical devices (IVD) known as the medical testing equipment in addition to early and accurate diagnosis, as well as effective monitoring of patient treatment. "Medical Technology" is a very professional industry knowledge and application of the medical laboratory is through the manufacturers to develop transferred to the medical practitioners, industrial and information technology improved rapidly in recent years, resulting in the medical inspection of product innovation; as knowledge economy era, the diversification of customer needs, business risk increases, more intense market competition, companies want to stand out in a competitive environment, it is necessary to construct their own core competence in order to create competitive advantage. Operators to think about how to find, identify the core competitiveness of the way, helping the enterprise training, consolidation, application and conversion of the core competitiveness in order to obtain sustainable competitive advantage.
In this study, on the one hand through literature, to understand the definition of the core competence, type and resolution; the other hand, the AHP method, defined in accordance with the core competence of literature, characteristics, and characteristics of the industry of medical testing equipment industry made the questionnaire,expert questionnaire, and a successful visit to the case of high-end decision-making management of mid-level management and senior grassroots cadres of 20 experts, to discuss the company's core competence of medical testing equipment.
According to the results: the core competence of the medical testing equipment industry in order (1) after-sales service, (2) professional and executive power, (3) high-end quality of decision making, (4) Product Marketing, (5) Management capabilities, (6) network capacity, (7) human Resource Management, (8) product competence, (9) organizational culture, (10) logistics Management, (11) Brand / goodwill (12) market coverage.
|
2 |
Micro-Biosensor Devices for Biochemical Analysis ApplicationsZhang, Han 01 May 2020 (has links)
A biosensor is an analytical device integrating a biological element and a physicochemical transducer that convert a biological response into a measurable signal. The advantages of biosensors include low cost, small size, quick, sensitivity and selectivity greater than the conventional instruments. Biosensors have a wide range of applications ranging from clinical diagnostics through to environmental monitoring, agriculture industry, et al.
The different types of biosensors are classified based on the sensor device as well as the biological material. Biosensors can be broadly classified into (piezoelectric, etc.), electrochemical biosensors (potentiometric, amperometric, etc.), and optical types of biosensors (fiber optics, etc.).
Here, we introduce a novel microfluidics-integrated biosensor platform system that can be flexibly adapted to form individual biosensors for different applications. In this dissertation, we present five examples of different emerging areas with this biosensor system including anti-cancer drug screening, glucose monitoring, heavy metal elements measurement, obesity healthcare, and waterborne pathogen DNA detection. These micro-biosensors have great potential to be further developed to emerging portable sensing devices especially for the uses in the developing and undeveloped world. At the last chapter, Raman spectroscopy applied to assess gestational status and the potential for pregnancy complications is presented and discussed. This technique could significantly benefit animal reproduction.
|
3 |
Dégénérescence discale et outils de diagnostics : couplage d'un modèle osmotico-mécanique et d'imagerie de résonance magnétique nucléaire / Disc degeneration and diagnosis toolsGhiss, Moncef 09 September 2014 (has links)
La dégénérescence discale (DD) est un problème majeur de santé publique dans les pays industrialisés où elle touche une grande partie de la population. Elle est considérée comme l'une des premières causes de consultation antidouleur et d'arrêt de maladie particulièrement en France. La présente étude s'inscrit dans le cadre du diagnostic de la DD et plus largement de l'évaluation de la fonctionnalité et de la viabilité du disque intervertébral (DIV).Le DIV est un fibrocartilage hétérogène qui assure d'une part la mobilité du rachis et d'autre part la distribution des contraintes mécaniques entre les vertèbres. Ces deux propriétés principales sont liées à la fois au contenu hydrique et à la présence des protéoglycanes (PG) dans le DIV.Plusieurs études ont montré l'importance de la teneur en eau du DIV sur son comportement biomécanique. Le but de notre étude est constitué de deux étapes:1. suivre avec une méthode d'Imagerie de Résonance Magnétique (IRM), les variations de morphologie et d'hydratation sous un chargement mécanique, 2. suivre avec une modélisation numérique, les évolutions des paramètres mécaniques notamment la rigidité, le coefficient de Poisson et la perméabilité intrinsèque du DIV.Les résultats ainsi obtenus sont conformes avec la littérature et le comportement retenu adhère parfaitement avec le cadre expérimental. Ce travail d'exploration de la viabilité discale apporte des informations importantes dans la compréhension du comportement osmotico-mécanique du DIV. / Disc diseases are major public health problem in industrialized countries where they affect a large proportion of the population. Disc degeneration (DD) is considered to be one of the leading causes of pain consultation and sick leave in France. This study is an attempt to diagnose DD and more generally an assessment of the functionality and viability of the InterVertebral Disc (IVD). The IVD is an heterogeneous cartilage, that ensures rachis mobility and optimal stress redistribution between vertebrae. These two main properties are linked to the hydric content and the presence of proteoglycans (PG) which decline in a natural process throughout life. This degenerative process is in some case accelerated, leading to the Degenerative Disc Diseases (DDD) or troubles. Several studies have shown the importance of the water content of the disc on its biomechanical behavior. The aims of our study are:1. to follow with Magnetic Resonance Imaging (MRI), the variation in morphology and hydration under mechanical stress,2. to follow with a numerical model, the changes in mechanical parameters such as stiffness, Poisson's ratio and the intrinsic permeability of the IVD.The post-processing on Magnetic Resonance (MR) data allowed reconstructing the 3D deformation under a known mechanical load and deducing the porosity of the disc. The results obtained are conform with the literature and the adopted behavior adheres perfectly with the experimental data. This study demonstrates also, the ability to calculate the mechanical parameters of an IVD, providing precious information to understand the mechanical behaviour and hence judge the viability of the IVD.
|
4 |
Restoration of Aluminum Aerospace Parts and Coatings Using Cold Gas Dynamic SprayingMacDonald, Daniel January 2014 (has links)
The majority of the structural weight of many common commercial aircrafts is composed of high strength aluminum alloys. The properties of high performance aluminum alloys such as a high strength to weight ratio (specific strength), ease of recycling, crash energy absorption capacity, and corrosion resistance make them ideal for use in the aerospace field. As a result of the high performance nature of the parts and specific properties of the materials, manufacturing requires intricate casting, precision machining, and specific heat treatments – which results in expensive components. As a result of its excellent corrosion resistance properties, pure aluminum coatings are commonly used in the aerospace field for corrosion protection of steel, aluminum alloy components, and titanium alloy components. The common method to deposit these coatings is called ion vapour deposition (IVD). These IVD aluminum coatings provide the coating adhesion, coverage, thickness, and corrosion resistance required to protect the part. The present study was motivated by the potential use of the cold gas dynamic spray (CGDS) process to repair a) damaged aluminum alloy aerospace parts and b) damaged pure aluminum IVD coatings. The primary research objective was to successfully produce these repairs using commercially available aluminum alloy feedstock powders deposited with commercially available CGDS equipment. This work was treated as prequalification work for The Boeing Company to commercialize this process and therefore the repairs aim to meet the same standards (military and industrial) required of the original aluminum alloy parts and IVD aluminum coatings.
The use of CGDS was shown in this research to be a very promising as a process for the restoration of aluminum alloy aerospace components. The adhesion strength of the repaired aluminum components was found to be well above the accepted range for thermally sprayed repairs according to industrial standards. The repairs were subjected to a highly corrosive environment and showed only minor pitting. These sites could be reduced in the future with improved machining techniques and attention to surface detail prior to exposure to the salt fog. The only requirement that the repaired components did not meet was for the wear properties of the anodized layer, measured thought Taber abrasion testing. The results of this test, at times, approached the desired values, and it is believed that, in the future, the quality and consistency of the coatings could be improved and the test would meet industrial standards.
The results of this research show that the use of CGDS as a process for the restoration of damaged aluminum IVD coatings is possible and is a promising alternative to conventional methods. The CGDS coatings were scrutinized to the same level as required of IVD coatings when they replaced toxic cadmium coatings in the late 1980s. The coating adhesion, demonstrated through glass bead abrasion and strip rupture testing, was shown to meet the current industrial standards. The corrosion testing of the repairs resulted in no visible red rust of the steel components, even when the steel was exposed.
|
5 |
Direct Assessment of Osmotic Pressure within Intervertebral Disc Tissue via a Needle Micro-OsmometerKeckler, Jesse 26 August 2019 (has links)
No description available.
|
6 |
Metodologías bioanalíticas para el diagnóstico in vitro de alergia a antibióticos ß-lactámicosJuárez Rodriguez, María José 12 July 2022 (has links)
[ES] Los fármacos pertenecientes a la familia de los ß-lactámicos son los antibióticos más usados en todo el mundo. Estudios recientes revelan que hasta un 10% de la población refiere haber presentado síntomas alérgico, esta porción de la población se considera "alérgica".
En el diagnóstico de la alergia a antibióticos ß-lactámicos existen varios tipos de pruebas que sirven para orientar y confirmar la presencia de una alergia, clasificadas como ensayos in vivo e in vitro. En lo que se refiere a los ensayos in vivo, la detección de los procesos alérgicos más comunes se realiza mediante pruebas de exposición oral controladas, y pruebas intraepidérmicas e intradérmicas. No obstante, estas pruebas tienen sus limitaciones como es el riesgo de inducir reacciones alérgicas sistémicas graves. Por todo ello, su práctica requiere personal entrenado. Este requisito limitan la realización de este tipo de pruebas a centros hospitalarios especializados.
La aplicación y desarrollo de técnicas de diagnóstico in vitro tiene como objetivo llegar a un diagnóstico de la alergia sin riesgos para el paciente. Entre las distintas pruebas serológicas y celulares que se pueden emplear, la detección de IgE específica es una de las más extendidas debido a que, dada su sensibilidad y especificidad, y mayor seguridad.
Los sistemas de diagnóstico in vitro actuales utilizan una instrumentación analítica cara y de gran tamaño, así como materiales desechables caros, manejados por personal cualificado, por lo que este tipo de pruebas se realizan únicamente por servicios de alergia y/o análisis clínicos de grandes centros sanitarios. En consecuencia, hay una necesidad de desarrollar nuevos métodos de diagnóstico que cumplan los requisitos de sensibilidad, rapidez, sencillez, multiplexado y portabilidad, a un precio reducido para su implantación en todo tipo de laboratorios clínicos de los diferentes niveles de atención sanitaria.
Por este motivo, en esta tesis doctoral se plantea como objetivo principal la puesta a punto de un inmunoensayo múltiple, utilizando la tecnología de disco compacto para la detección y cuantificación in vitro de niveles de IgE específica a un amplio espectro de antibióticos ß-lactámicos en muestras de suero humano.
Las limitaciones más críticas para la determinación de IgE específica multianalito mediante métodos inmunoquímicos son las relacionados con la sensibilidad y selectividad. Por lo tanto, una parte importante de la tesis se ha centrado en la preparación y caracterización de un panel antígenos ß-lactámicos, selección de inmunoreactivos, formato y estudio de diferentes parámetros claves del inmunoensayo.
Otra parte importante de la tesis se ha enfocado en abordar la mejora de la reproducibilidad de los resultados. La estrategia ha consistido en estudiar diferentes sistemas de calibración con el objetivo de estandarizar la cuantificación de los métodos in vitro de diagnóstico de este tipo de alergias. Para ello, se han evaluado las prestaciones de la calibración homóloga, heteróloga y el uso de un patrón interno, comparado sus prestaciones analíticas (relación señal ruido, sensibilidad, reproducibilidad, etc.) con el sistema de referencia. Finalmente, la validación del inmunoensayo se realizó con un conjunto de 101 muestras de suero de pacientes y controles. Los resultados obtenidos han sido comparados con los obtenidos mediante las técnicas de referencia, mostrando una mejor sensibilidad, especificidad, precisión, y linealidad.
La capacidad múltiplex de la tecnología de disco compacto permitió llevar a cabo paralelamente estudios de reactividad cruzada frente a diferentes antibióticos ß-lactámicos esclareciendo el patrón de reconocimiento de los pacientes. En esta línea de trabajo, el uso de otras estrategias de conjugación de haptenos ha resultado en la mejora de la sensibilidad clínica del ensayo, identificando nuevos epítopos / [CA] Els fàrmacs que pertanyen a la família dels beta-lactams, són els antibiòtics d'us més estès a tot el món. Estudis recents posen de manifest que fins un 10% de la població ha presentat símptomes d'al·lèrgia, essent considerats població al·lèrgica als beta-lactams. En el diagnòstic de l'al·lèrgia front aquest tipus d'antibiòtics, existeixen diferents tipus de proves que serveixen per orientar i confirmar la presència d'una al·lèrgia, classificades com assajos in vivo i in vitro. Pel que fa als assajos in vivo, la detecció dels processos al·lèrgics més comuns es realitza mitjançant proves d'exposició oral controlades, i proves intra-epidèrmiques i intradèrmiques. No obstant això, aquestes proves tenen les seues limitacions com és el risc d'induir reaccions al·lèrgiques sistèmiques greus. Per tot això, la seua pràctica requereix personal entrenat. Aquests requisits limiten la realització d'aquesta mena de proves a centres hospitalaris especialitzats. L'aplicació i desenvolupament de tècniques de diagnòstic in vitro té com a objectiu arribar a un diagnòstic de l'al·lèrgia sense riscos per al pacient. Entre les diferents proves serològiques i cel·lulars que es poden emprar, la detecció d'IgE específica és una de les més esteses donada la seua sensibilitat, especificitat, i major seguretat. Els sistemes de diagnòstic in vitro actuals utilitzen una instrumentació analítica cara i de gran grandària, així com materials d'un sol ús també cars, que requereixen de personal qualificat, per la qual cosa aquest tipus de proves es realitzen únicament per serveis d'al·lèrgia i/o anàlisis clíniques de grans centres sanitaris. En conseqüència, hi ha una necessitat de desenvolupar nous mètodes de diagnòstic que complisquen els requisits de sensibilitat, rapidesa, senzillesa, multiplexatge i portabilitat, a un preu reduït per a la seua implantació en tota mena de laboratoris clínics dels diferents nivells d'atenció sanitària. Per aquest motiu, en aquesta tesi doctoral es planteja com a objectiu principal la posada a punt d'un immunoassaig múltiple, utilitzant la tecnologia de disc compacte per a la detecció i quantificació in vitro de nivells d'IgE específica a un ampli espectre d'antibiòtics ß-lactáms en mostres de sèrum humà. Les limitacions més crítiques per a la determinació d'IgE específica multianàlit mitjançant mètodes inmunoquímics estan directament relacionades amb la sensibilitat i selectivitat. Per tant, una part important de la tesi s'ha centrat en la preparació i caracterització d'un panell antígens ß-lactáms, selecció d'inmunoreactius, del format d'assaig i estudi de diferents paràmetres claus de l'immunoassaig. Una altra part important de la tesi s'ha enfocat a abordar la millora de la reproductibilitat dels resultats. L'estratègia ha consistit a estudiar diferents sistemes de calibratge amb l'objectiu d'estandarditzar la quantificació dels mètodes in vitro de diagnòstic d'aquesta mena d'al·lèrgies. Per a això, s'han avaluat les prestacions del calibratge homòleg, heteròleg i l'ús d'un patró intern, comparant les seues prestacions analítiques (relació senyal soroll, sensibilitat, reproductibilitat, etc.) amb el sistema de referència. Finalment, la validació de l'immunoassaig es va realitzar amb un conjunt de 101 mostres de sèrum de pacients i controls. Els resultats obtinguts han sigut comparats amb els obtinguts mitjançant les tècniques de referència, mostrant una millor sensibilitat, especificitat, precisió, i linealitat. La capacitat múltiplex de la tecnologia de disc compacte va permetre dur a terme paral·lelament estudis de reactivitat creuada enfront de diferents antibiòtics ß-lactáms esclarint el patró de reconeixement dels pacients. En aquesta línia de treball, l'ús d'altres estratègies de conjugació d'haptens ha resultat en la millora de la sensibilitat clínica de l'assaig, identificant nous epítops / [EN] ß-lactam antibiotics are one of the most widely used antimicrobials worldwide. However, up to 10% of the population reports having presented allergic symptoms derived from their consumption. Consequently, this portion of the population is considered "allergic".
In the diagnosis of allergy to ß-lactam antibiotics there are several types of tests that serve to orient and confirm the presence of an allergy. These diagnostic methods are classified as in vivo and in vitro assays. Regarding in vivo tests, the most standardized tests are the provocation, prick and intradermal test. The aim of these assays is to observe the response produced by the different beta-lactam antibiotics in the patient after oral or cutaneous administration. Despite their wide use, these tests have their limitations, such as the risk of inducing severe systemic allergic reactions. Therefore, their practice requires specialized professionals for their indication, performance and interpretation. This requirement limit the performance of this type of test to specialized hospitals.
The use and development of in vitro diagnostic techniques can overcome these disadvantages and allow the diagnosis of allergy without risks. In vitro assays are less invasive and therefore neither pose a risk of adverse reactions. Among the different serological and cellular tests that can be used, the detection of specific IgE is one of the most widespread due to its sensitivity and specificity.
Current in vitro diagnostic systems use expensive and bulky analytical instrumentation and high-cost single-use materials, handled by qualified professionals. Therefore, such tests are performed only by allergy and/or clinical analysis services of hospitals or by companies specialized in clinical diagnostics. Consequently, there is a need to develop new diagnostic methods that can be implemented in all types of clinical laboratories at diverse levels of health care, meeting the requirements of sensitivity, speed, simplicity, multiplexing and portability at a reduced price.
For this reason, the main objective of this doctoral thesis is the development of a multiplex immunoassay using compact disc technology for the detection and quantification of specific IgE levels to a wide variety of ß-lactam antibiotics in human serum samples.
The most crucial limitations for the determination of multianalyte specific IgE by immunochemical methods are those related to sensitivity and selectivity. Hence, an important part of the thesis has been focused on the preparation and characterization of a pool of beta-lactam antigens, selection of immunoreagents, format and optimization of different critical parameters of the immunoassay.
Another important aspect of the thesis has been focused on improving the reproducibility of the results. The strategy consisted of studying different calibration systems with the aim of standardizing the quantification of in vitro diagnostic tests for this type of allergy. To achieve that goal, the performance of homologous and heterologous calibration and the use of an internal standard have been evaluated, comparing their analytical performance (signal-to-noise ratio, sensitivity, reproducibility, etc.) with the reference system.
Finally, the validation of the immunoassay was performed with a total of 101 serum samples from patients and controls. The results obtained have been compared with those obtained using the reference techniques, showing improved sensitivity, specificity, precision, and linearity.
The multiplex capability of the compact disc technology allowed carrying out parallel cross-reactivity studies against different beta-lactam antibiotics both from the penicillin family and from other families, elucidating the recognition profile. Following this working line, the use of other hapten conjugation strategies improved clinical sensitivity of the assay by identifying new epitopes. / Juárez Rodriguez, MJ. (2022). Metodologías bioanalíticas para el diagnóstico in vitro de alergia a antibióticos ß-lactámicos [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/184011 / Premios Extraordinarios de tesis doctorales
|
7 |
Diseño, obtención y caracterización de proteínas recombinantes a partir de determinantes antigénicos asociadas a reacciones alérgicas a ß-lactámicos.Quintero Campos, Pedro 16 January 2023 (has links)
Tesis por compendio / [ES] El diagnóstico de alergias a antibióticos ß-lactámicos incluye el uso de pruebas in vivo no satisfactorias ya que consumen mucho tiempo y conllevan el riesgo de provocar una nueva reacción alérgica. Por otro lado, los métodos in vitro basados en la inmunodetección de IgE alérgeno-específica generan una información muy valiosa, confirmando o descartando la alergia y postulándose como una alternativa de diagnóstico segura. A pesar de ello, las pruebas in vitro actuales carecen de sensibilidad y exactitud, con un 81% de falsos negativos, lo que limita su uso diagnóstico.
Esto ha desencadenado una creciente demanda de nuevas pruebas in vitro basadas en la inmunodetección de IgE, el biomarcador presente en suero más estudiado en alergia. Sin embargo, la falta de estándares de referencia de IgE alérgeno-específica ha imposibilitado la validación y estandarización de los métodos, lo que hace que los resultados de las distintas pruebas no sean comparables. Además, dicha falta de estándares de referencia hace que las concentraciones de IgE específica se calculen a partir de una curva de calibración de IgE total mediante una interpolación heteróloga, lo que ha demostrado no ser totalmente correcto.
Por los motivos mencionados, en esta tesis doctoral se plantea como objetivo principal el diseño, obtención y caracterización de proteínas recombinantes con reactividad frente a antibióticos ß-lactámicos.
Esta investigación comienza con la puesta a punto de un inmunoensayo en placa ELISA con detección quimioluminiscente para la cuantificación de IgE específica. El ensayo desarrollado permitió determinar IgE específica por debajo de 0.1 IU/mL (0.24 ng/mL), permitiendo así la identificación de pacientes alérgicos con una mayor sensibilidad, utilizando solo 25 ¿L de muestra (suero). El inmunoensayo mostró una buena sensibilidad (64.6%), así como una excelente especificidad (100%), que mejoran significativamente el carácter predictivo de las pruebas in vitro existentes.
A continuación, se abordó la obtención y caracterización de proteínas recombinantes similares a las IgE específicas de los ß-lactámicos utilizando la metodología Phage Display. La primera aproximación se trata de una proteína formada por dos nanoanticuerpos que mimetiza el comportamiento de una IgE específica. De esta manera, se obtuvieron proteínas recombinantes en las que uno de los nanoanticuerpos reconoce selectivamente un determinante antigénico de un antibiótico ß-lactámico, mientras que el otro reconoce específicamente al parátopo de un anticuerpo detector anti-IgE. Estas construcciones resultaron ser estables y funcionales.
El papel de estas proteínas recombinantes como calibrador homólogo se estudió determinando la concentración de IgE específica a penicilina G presente en suero mediante un ensayo quimioluminiscente. El método desarrollado duplicaba la sensibilidad clínica (66%) frente al método de referencia (28%), mientras que mantenía una especificidad clínica del 100%.
Alcanzado este punto, la tesis se centró en la producción de IgE específica recombinante utilizando como material de partida el ADN de un paciente alérgico a amoxicilina y penicilina G. A partir del material genético aislado, mediante Phage Display, ingeniería de anticuerpos y métodos de expresión en células de insecto se consiguió producir una IgE específica recombinante. De esta manera, se obtuvo un producto biológico que cumple con los requisitos para su adopción como material de referencia en ensayos in vitro. Igualmente, se utilizó como calibrador homólogo para la determinación de IgE específica a amoxicilina. Se alcanzó un límite de detección de 0.05 IU/mL con el que se conseguía un aumento de la sensibilidad clínica (73%) que cuadruplicaba al método de referencia (16%), manteniendo la especificidad clínica en el 100%. / [CA] El diagnòstic d'al·lèrgies a antibiòtics ß-lactàmics inclou l'ús de proves in vivo no satisfactòries, ja que consumeixen molt de temps i comporten el risc de provocar una nova reacció al·lèrgica. D'altra banda, els mètodes in vitro basats en la immunodetecció d'IgE al·lergen-específica generen una informació molt valuosa, confirmant o descartant l'al·lèrgia i postulant-se com una alternativa de diagnòstic segura. Tanmateix, a les proves in vitro actuals hi ha una manca de sensibilitat i exactitud, amb un 81% de falsos negatius, cosa que en limita l'ús diagnòstic.
Tot això ha desembocat en una demanda creixent de noves proves in vitro basades en la immunodetecció d'IgE, el biomarcador present en sèrum més estudiat en al·lèrgia. No obstant això, la manca d'estàndards de referència d'IgE al·lergen-específica ha impossibilitat la validació i estandardització dels mètodes, cosa que fa que els resultats de les diferents proves no siguen comparables. A més, aquesta manca d'estàndards de referència fa que les concentracions d'IgE específica es calculen a partir d'una corba de calibratge d'IgE total mitjançant una interpolació heteròloga, un mètode que ha demostrat no ser totalment correcte ja que no es pren en consideració la interacció entre el determinant antigènic i la IgE específica.
Pels motius mencionats, en aquesta tesi doctoral es planteja com a objectiu principal el disseny, l'obtenció i la caracterització de proteïnes recombinants amb reactivitat davant dels antibiòtics ß-lactàmics.
Aquesta investigació comença amb la posada a punt d'un immunoassaig en placa ELISA amb detecció quimioluminiscent per a la quantificació d'IgE específica. L'assaig desenvolupat va permetre determinar IgE específica per baix de 0.1 IU/mL (0.24 ng/mL), el que permet la identificació de pacients al·lèrgics amb més sensibilitat, utilitzant només 25 ¿L de mostra (sèrum). L'immunoassaig mostra una bona sensibilitat (64.6%), així com una excel·lent especificitat (100%), que milloren significativament el caràcter predictiu de les proves in vitro existents.
A continuació, es va abordar l'obtenció i la caracterització de proteïnes recombinants similars a les IgE específiques dels ß-lactàmics utilitzant la metodologia Phage Display. La primera aproximació és una proteïna formada per dos nanoanticossos que mimetitza el comportament d'una IgE específica. D'aquesta manera, es van obtenir proteïnes recombinants en què un dels nanoanticossos reconeix selectivament un determinant antigènic d'un antibiòtic ß-lactàmic, mentre que l'altre reconeix específicament el paràtop d'un anticòs detector anti-IgE (Omalizumab). Aquestes construccions van resultar estables i funcionals.
El paper d'aquestes proteïnes recombinants com a calibrador homòleg es va estudiar determinant la concentració d'IgE específica a penicil·lina G present en sèrum mitjançant un assaig quimioluminiscent. El mètode desenvolupat duplicava la sensibilitat clínica (66%) respecte del mètode de referència (28%), mentre que mantenia una especificitat clínica del 100%.
Assolit aquest punt, la tesi es va centrar en la producció d'IgE específica recombinant utilitzant com a material de partida l'ADN d'un pacient al·lèrgic a amoxicil·lina i penicil·lina G. En combinació amb la metodologia Phage Display, enginyeria d'anticossos i mètodes d'expressió en cèl·lules d'insecte, es va aconseguir produir una IgE específica recombinant. D'aquesta manera, es va obtenir un producte biològic que compleix els requisits per ser adoptat com a material de referència en assajos in vitro. Igualment, es va utilitzar com a calibrador homòleg per a la determinació d'IgE específica a amoxicil·lina. Es va assolir un límit de detecció de 0.05 IU/mL amb què s'aconseguia un augment de la sensibilitat clínica (73%) que quadriplicava al mètode de referència (16%), mantenint l'especificitat clínica al 100%. / [EN] The diagnosis of ß-lactam antibiotics allergy involves using unsatisfactory in vivo tests that are time-consuming and carry the risk of triggering a new allergic reaction. On the other hand, in vitro methods based on allergen-specific IgE immunodetection generate precious information, confirming or ruling out allergies and postulating themselves as a safe diagnostic alternative. Despite this, current in vitro tests lack sensitivity and accuracy, with 81% false negatives limiting their diagnostic use.
This has led to a growing demand for new in vitro tests based on the immunodetection of IgE, the most studied biomarker in serum allergy. However, the lack of reference standards for allergen-specific IgE has made it impossible to validate and standardize methods, which means that the results of the different tests are not comparable. Furthermore, this lack of reference standards means that specific IgE concentrations are calculated from a total IgE calibration curve by heterologous interpolation, which has been shown not to be entirely correct.
For the reasons mentioned above, the main objective of this doctoral thesis is to design, obtain and characterize recombinant proteins with reactivity against ß-lactam antibiotics.
This research begins with developing an ELISA immunoassay with chemiluminescent detection for quantifying specific IgE. The assay developed allowed the determination of specific IgE below 0.1 IU/mL (0.24 ng/mL), thus allowing the identification of allergic patients with greater sensitivity, using only 25 µL of sample (serum). The immunoassay showed good sensitivity (64.6%) and excellent specificity (100%), significantly improving the predictive character of existing in vitro tests.
Next, the obtaining and characterizing recombinant proteins similar to ß-lactam-specific IgE was approached using the Phage Display methodology. The first approach deals with a protein consisting of two single-domain antibodies that mimics the behavior of a specific IgE. In this way, recombinant proteins were obtained in which one of the nanobodies selectively recognizes an antigenic determinant of a ß-lactam antibiotic, while the other specifically recognizes the paratope of an anti-IgE detector antibody. These constructs were found to be stable and functional.
The role of these recombinant proteins as a homologous calibrator was studied by determining the concentration of penicillin G-specific IgE present in serum by employing a chemiluminescent assay. The developed method doubled the clinical sensitivity (66%) compared to the reference method (28%), while maintaining a clinical specificity of 100%.
At this point, the thesis focused on the production of recombinant specific IgE using as starting material the DNA of a patient allergic to amoxicillin and penicillin G. in combination with the Phage Display, antibody engineering and expression methods in insect cells, a recombinant-specific IgE was produced. In this way, a biological product was obtained that meets the requirements for its adoption as reference material in in vitro assays. Likewise, it was used as a homologous calibrator for the determination of specific IgE to amoxicillin. A detection limit of 0.05 IU/mL was achieved, which increased clinical sensitivity (73%) fourfold compared to the reference method (16%), while maintaining clinical specificity at 100%. / This work was supported by CSIC 2007-348, ANII FMV 2019_156321, and ANII FMV 2018_148245. P.Q.-C. acknowledges financial support from Generalitat Valenciana through the research staff training program (GVA ACIF/2018/173). This research was also funded by Agencia Estatal de Investigación (PID2019-110713RB-I00, FEDER), program UPV-La FE 2019 (P105 VALBIOAL), and PROMETEO/ 2020/094 / Quintero Campos, P. (2022). Diseño, obtención y caracterización de proteínas recombinantes a partir de determinantes antigénicos asociadas a reacciones alérgicas a ß-lactámicos [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/191429 / Compendio
|
8 |
Fúze a akvizice v IVD / Mergers and Acquisitions in IVDGašpar, Tomáš January 2011 (has links)
The essential goal of the thesis is to confirm or reject the hypothesis that mergers and acquisitions are an effective way how to grow the value of a company, especially in the regulated environment of the Czech healthcare. The theses focuses mainly on human IVD laboratories though the most of the content relates to the healthcare as a whole. On one hand the theses offers a view of the pure theory of M&A's, on the other hand its connection to reality.The basic processes are the definition of the IVD market, analyses of the sources of income in the healthcare in relation to the possibilities of company value growth. At the end of the thesis the hypothesis is verified by a real lab acquisition case.
|
9 |
Kvantifikace axiálního systému člověka metodou TVS / Quantification of the axial system of humans by the TVS methodBenyovszky, Adam January 2015 (has links)
Title: Quantification of the axial system of humans by the TVS method Objective: The aim of this thesis is to introduce the TVS method as an adequate method for determining the biomechanical properties of the human axial system (AS). Method: This thesis presents data analysis from a series of case studies, which were obtained during the development of the TVS method. The data for the analysis were selected by the TVS measurements two times during the pregnancy of six women. On two sections of AS (Th2-Th9 and T11-L2), we examined the ability to soften vibrations of AS with regard to the stage of pregnancy. The results are quantified and provide information about the resonant frequencies, stiffness and damping of selected parts of AS. Results: The TVS method seemed to be adequate to provide information about the change of mechanical properties in depending on the selected parameter and allows the quantification of the biomechanical properties of AS. The results showed the improvement of damping parameter in case of four respondents, whereas the deterioration in case of two respondents. Keywords: IVD, Transfer Vibration through Spine, transmitting mechanical vibrations by the axial system, damping and throughput AS
|
10 |
Investigation of MarrowMAX: Increased Mitotic Index and Improved Metaphase Quality in Bone Marrow SamplesBaroudi, Raghad January 2024 (has links)
In this study, the efficacy of MarrowMAX, a new IVD-certified culture medium for bone marrow samples, was evaluated and compared to the in-house modified culture medium RPMI-1640, which is routinely used at the Academic Hospital in Uppsala for chromosomal analysis. The hypothesis was that the new culture medium MarrowMAX would lead to an increased number of metaphases, resulting in a higher mitotic index, better spreading, and improved metaphase morphology. Twenty patient samples were cultured in parallel using both media and subjected to identical methods for sample preparation and staining for chromosomal analysis. The results demonstrated significant differences between MarrowMAX and RPMI-1640 for one-day, two-day, and three-day cultures. However, no significant differences were observed for directly harvested cultures and overnight colcemid cultures. These findings suggest that MarrowMAX is more effective than RPMI-1640, resulting in a higher frequency of metaphases, which is crucial for detailed chromosomal analysis. This was further confirmed by flow cytometry analysis, showing a higher number of proliferated cells in the MarrowMAX culture compared to the RPMI-1640 culture, in one representative sample. MarrowMAX's enhanced capacity to promote cell growth and structure in a laboratory setting indicates its potential as a promising alternative to RPMI-1640 for future diagnostic applications, potentially leading to faster diagnoses and improved treatment efficacy for patients with hematological conditions.
|
Page generated in 0.0501 seconds