• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 27
  • 3
  • Tagged with
  • 66
  • 66
  • 22
  • 21
  • 11
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Magnetic Resonance Imaging in Proximity to Metal Implants at 3 Tesla / Magnetresonanzbildgebung nahe metallischer Implantate bei 3 Tesla

Bachschmidt, Theresa January 2015 (has links) (PDF)
Magnetic resonance imaging is derogated by the presence of metal implants and image quality is impaired. Artifacts are categorized according to their sources, the differences in susceptibility between metal and tissue and the modulation of the magnetic radiofrequency (RF) transmit field. Generally, these artifacts are intensified at higher field strength. The purpose of this work is to analyze the efficiency of current methods used for metal artifact reduction at 3T and to investigate improvements. The impact of high-bandwidth RF pulses on susceptibility-induced artifacts is tested. In addition, the benefit of a two-channel transmit system with respect to shading close to total hip replacements and other elongated metal structures in parallel to the magnetic field is analyzed. Local transmit/receive coils feature a higher peak B1 amplitude than conventional body coils and thus enable high-bandwidth RF pulses. Susceptibility-induced through-plane distortion relates reciprocally to the RF bandwidth, which is evaluated in vitro for a total knee arthroplasty. Clinically relevant sequences (TSE and SEMAC) with conventional and high RF pulse bandwidths and different contrasts are tested on eight patients with different types of knee implants. Distortion is rated by two radiologists. An additional analysis assesses the capability of a local spine transmit coil. Furthermore, B1 effects close to elongated metal structures are described by an analytical model comprising a water cylinder and a metal rod, which is verified numerically and experimentally. The dependence of the optimal polarization of the transmit B1 field, creating minimum shading, on the position of the metal is analyzed. In addition, the optimal polarization is determined for two patients; its benefit compared to circular polarization is assessed. Phantom experiments confirm the relation of the RF bandwidth and the through-plane distortion, which can be reduced by up to 79% by exploitation of a commercial local transmit/receive knee coil at 3T. On average, artifacts are rated “hardly visible” for patients with joint arthroplasties, when high-bandwidth RF pulses and SEMAC are used, and for patients with titanium fixtures, when high-bandwidth RF pulses are used in combination with TSE. The benefits of the local spine transmit coil are less compared to the knee coil, but enable a bandwidth 3.9 times as high as the body coil. The modulation of B1 due to metal is approximated well by the model presented and the position of the metal has strong influence on this effect. The optimal polarization can mitigate shading substantially. In conclusion, through-plane distortion and related artifacts can be reduced significantly by the application of high-bandwidth RF pulses by local transmit coils at 3T. Parallel transmission offers an option to substantially reduce shading close to long metal structures aligned with the magnetic field. Effective techniques dedicated for metal implant imaging at 3T are introduced in this work. / Metallimplantate beeinträchtigen die Funktionsweise der Magnetresonanztomographie und verschlechtern die Bildqualität. Die Artefakte werden entsprechend ihres Ursprungs kategorisiert, in einerseits Suszeptibilitätsunterschiede zwischen Metall und Gewebe und andererseits die Modulation des B1-Feldes. Im Allgemeinen verstärken sich diese Artefakte bei höheren Feldstärken. Das Ziel dieser Arbeit ist es, die Effizienz vorhandener Methoden zur Artefaktreduktion bei 3T zu bewerten und mögliche Verbesserungen herauszuarbeiten. Der Einfluss von breitbandigen Hochfrequenz-Pulsen (HF-Pulsen) auf Suszeptibilitätsartefakte wird untersucht. Zusätzlich wird der Einfluss eines Zwei-Kanal Sendesystems auf Abschattungen analysiert, die in der Nähe von Hüftimplantaten und anderen länglichen Implantaten auftreten, welche parallel zu B0 liegen. Im Gegensatz zu konventionellen Ganzkörper-Sendespulen erlauben lokale Sende-/Empfangsspulen eine höhere maximale B1-Amplitude, die breitbandigere HF-Pulse ermöglicht. Die reziproke Abhängigkeit der Suszeptibilitätsartefakte in Schichtrichtung zur HF-Bandbreite wird in vitro für eine Kniegelenkplastik evaluiert. An acht Patienten mit verschiedenen Knieimplantaten werden klinisch relevante Sequenzen (TSE und SEMAC) mit konventionellen und breitbandigen HF-Pulsen in verschiedenen Kontrasten getestet und die Verzerrungen werden von zwei Radiologen bewertet. Eine weitere Studie untersucht das Potenzial einer lokalen Sendespule für die Wirbelsäule. Darüberhinaus werden B1-Effekte nahe länglicher Metallstrukturen durch ein analytisches Modell beschrieben, das numerisch und experimentell überprüft wird. Des Weiteren wird die Abhängigkeit der optimalen Polarisation des B1-Feldes, die minimale Abschattung verursacht, von der Position des Metalls untersucht. Für zwei Patienten wird die optimale Polarisation bestimmt und deren Vorteil gegenüber der zirkularen Polarisation analysiert. Phantomversuche bestätigen die Abhängigkeit zwischen HF-Bandbreite und der Schichtverzerrung, die durch die Verwendung einer lokalen Kniespule mit Sende- und Empfangsfunktion bei 3T um 79% reduziert werden kann. Die Artefakte bei Patienten mit Vollimplantaten, bzw. Titanimplantaten, werden als "kaum sichtbar" bewertet, wenn SEMAC, bzw. TSE, mit breitbandigen HF-Pulsen kombiniert appliziert wird. Im Vergleich zur lokalen Kniespule fallen die Vorteile der lokalen Wirbelsäulen-Sendespule geringer aus; dennoch kann die 3,9-fache HF-Bandbreite der Ganzkörpersendespule erreicht werden. Die B1-Modulation aufgrund von Metall wird im dargestellten Modell gut wiedergegeben und die Position des Metalls im Objekt hat großen Einfluss auf den Effekt. Die Verwendung der optimalen Polarisation kann Abschattungen stark reduzieren. Zusammenfassend können Artefakte aufgrund von Schichtverzerrungen durch die Verwendung lokaler Sendespulen und breitbandiger HF-Pulse bei 3T stark abgeschwächt werden. Die individuelle Wahl der Polarisation des B1-Feldes bietet eine gute Möglichkeit, Abschattungen in der Nähe von länglichen Metallstrukturen zu reduzieren, soweit diese näherungsweise parallel zu B0 ausgerichtet sind. Somit werden in dieser Arbeit wirksame Methoden zur Metallbildgebung bei 3T eingeführt.
52

Reconstruction methods for the frequency-modulated balanced steady-state free precession MRI-sequence / Rekonstruktionsmethoden für die frequenz-modulierte balanced steady-state free precession MRT-Sequenz

Slawig, Anne January 2018 (has links) (PDF)
This work considered the frequency-modulated balanced steady-state free precession (fm-bSSFP) sequence as a tool to provide banding free bSSFP MR images. The sequence was implemented and successfully applied to suppress bandings in various in vitro and in vivo examples. In combination with a radial trajectory it is a promising alternative for standard bSSFP applications. First, two specialized applications were shown to establish the benefits of the acquisition strategy in itself. In real time cardiac imaging, it was shown that the continuous shift in frequency causes a movement of the bandings across the FOV. Thus, no anatomical region is constantly impaired, and a suitable timeframe can be found to examine all important structures. Furthermore, a combination of images with different artifact positions, similar to phase-cycled acquisitions is possible. In this way, fast, banding-free imaging of the moving heart was realized. Second, acquisitions with long TR were shown. While standard bSSFP suffers from increasing incidence of bandings with higher TR values, the frequency-modulated approach provided banding free images, regardless of the TR. A huge disadvantage of fm-bSSFP, in combination with the radial trajectory, is the decrease in signal intensity. In this work a specialized reconstruction method, the multifrequency reconstruction for frequency-modulated bSSFP (Muffm), was established, which successfully compensated that phenomena. The application of Muffm to several anatomical sites, such as inner ear, legs and cardiac acquisitions, proofed the advantageous SNR of the reconstruction. Furthermore, fm-bSSFP was applied to the clinically highly relevant task of water-fat separation. Former approaches of a phase-sensitive separation procedure in combination with standard bSSFP showed promising results but failed in cases of high inhomogeneity or high field strengths where banding artifacts become a major issue. The novel approach of using the fm-bSSFP acquisition strategy with the separation approach provided robust, reliable images of high quality. Again, losses in signal intensity could be regained by Muffm, as both approaches are completely compatible. Opposed to conventional banding suppression techniques, like frequency-scouts or phase-cycling, all reconstruction methods established in this work rely on a single radial acquisition, with scan times similar to standard bSSFP scans. No prolonged measurement times occur and patient time in the scanner is kept as short as possible, improving patient comfort, susceptibility to motion or physiological noise and cost of one scan. All in all, the frequency-modulated acquisition in combination with specializes reconstruction methods, leads to a completely new quality of images with short acquisition times. / In dieser Arbeit wird eine Modifikation der balanced steady-state free precession (bSSFP) Sequenz betrachtet. Die frequenzmodulierte bSSFP-Sequenz (fm-bSSFP) kann die sonst typischen Band-Artefakte in bSSFP-MR-Bildern verhindern. Die Sequenz wurde im Rahmen der Arbeit am MR-Scanner implementiert und erfolgreich in verschiedenen in-vitro- und in-vivo-Beispielen angewendet. In Kombination mit einer radialen Trajektorie erwies es sich als eine vielversprechende Alternative für alle Standard-bSSFP Anwendungen. Zuerst wurden zwei spezialisierte Anwendungen gezeigt, um die Vorteile der Akquisitionsstrategie an sich darzustellen. Am Beispiel der Echtzeit-Herzbildgebung konnte mit Hilfe der kontinuierlichen Frequenzverschiebung eine Bewegung der Bänder über das FOV erzeugt werden. Somit wird keine anatomische Region ständig von Artefakten überlagert und für jeden Bereich kann ein geeigneter Zeitrahmen gefunden werden, um die wichtigen Strukturen darzustellen und zu untersuchen. Darüber hinaus ist eine Kombination von Bildern mit verschiedenen Artefaktpositionen möglich, ähnlich zu mehreren Aufnahmen mit verschiedenen Phasenzyklen. Auf diese Weise wurde eine schnelle Bildgebung des sich bewegenden Herzens ohne Bandartefakte realisiert. Zusätzlich wurden Aufnahmen mit langen Repetitionszeiten (TR) untersucht. Während in der Standard-bSSFP die Häufigkeit von Bandartefakten mit steigendem TR-Wert zunimmt, lieferte der frequenzmodulierte Ansatz Banding-freie Bilder unabhängig vom TR. Ein großer Nachteil von fm-bSSFP in Kombination mit der radialen Trajektorie ist der Verlust von Signalintensität bei der Rekonstruktion. In dieser Arbeit wurde eine spezielle Rekonstruktionsmethode namens Muffm (mulitfrequency reconstruction for frequency-modulated bSSFP) etabliert, die diesen Verlust erfolgreich kompensieren kann. Die Anwendung von Muffm an verschiedenen anatomischen Strukturen, wie Innenohr, Bein und Herzaufnahmen, bestätigte das vorteilhafte Signal-zu-Rausch-Verhältnis, dass durch die spezielle Rekonstruktion gewonnen werden kann. Darüber hinaus wurde die fm-bSSFP auf die klinisch interessante Wasser-Fett-Trennung angewandt. Frühere Ansätze eines phasenempfindlichen Trennverfahrens in Kombination mit Standard-bSSFP zeigten vielversprechende Ergebnisse, scheiterten jedoch in Fällen hoher Inhomogenität oder hoher Feldstärken an den auftretenden Bandartefakten. Der neue Ansatz, diesen Separationsalgorithmus mit der fm-bSSFP-Akquisitionsstrategie zu verbinden, lieferte robuste, zuverlässige Bilder von hoher Qualität. Auch hier konnten entstehende Verluste in der Signalintensität durch Muffm zurückgewonnen werden, da beide Ansätze vollständig kompatibel sind. Im Gegensatz zu herkömmlichen Bandunterdrückungstechniken, wie Frequenz-Scouts oder die Aufnahme mehrerer Bilder mit verschiedenen Phasenzyklen, beruhen alle in dieser Arbeit etablierten Rekonstruktionsverfahren auf einer einzigen radialen Aufnahme. Die Messzeiten sind daher identisch zur Aufnahme einer Standard-bSSFP Messung. Das Verfahren ermöglicht eine deutliche Verkürzung der Aufenthaltsdauer im Scanner bei einer gleichzeitigen Garantie ein artefaktfreies Bild zu erhalten. Damit ist es insbesondere für Patienten von Vorteil, die unter Platzangst oder sonstigen Beschwerden leiden, die ein langes Stillliegen erschweren. Außerdem werden Bewegungsartefakte, physiologisches Rauschen und nicht zuletzt die Kosten eines Scans minimiert. Insgesamt bietet die frequenzmodulierte bSSFP Aufnahme in Kombination mit spezialisierten Rekonstruktionsverfahren neue Möglichkeiten zur schnellen Aufnahme von Bildern ohne Bandartefakte.
53

Accelerated non-Cartesian cardiovascular MR Imaging at 3T and 7T / Beschleunigte nicht-kartesische MRT Herzbildgebung bei 3T und 7T

Eirich, Philipp January 2022 (has links) (PDF)
In this work, accelerated non-Cartesian Magnetic Resonance Imaging (MRI) methods were established and applied to cardiovascular imaging (CMR) at different magnetic field strengths (3T and 7T). To enable rapid data acquisition, highly efficient spiral k-space trajectories were created. In addition, hybrid sampling patterns such as the twisting radial lines (TWIRL) k-space trajectory were studied. Imperfections of the dynamic gradient system of a MR scanner result in k-space sampling errors. Ultimately, these errors can lead to image artifacts in non-Cartesian acquisitions. Among other reasons such as an increased reconstruction complexity, they cause the lack of spiral sequences in clinical routine compared to standard Cartesian imaging. Therefore, the Gradient System Transfer Functions (GSTFs) of both scanners were determined and used for k-space trajectory correction in post-correction as well as in terms of a pre-emphasis. The GSTF pre-emphasis was implemented as a fully automatic procedure, which enabled a precise correction of arbitrary gradient waveforms for double-oblique slice orientations. Consequently, artifacts due to trajectory errors could be mitigated, which resulted in high image quality in non-Cartesian MRI. Additionally, the GSTF correction was validated by measuring pre-emphasized spiral gradient outputs, which showed high agreement with the theoretical gradient waveforms. Furthermore, it could be demonstrated that the performance of the GSTF correction is superior to a simple delay compensation approach. The developed pulse sequences were applied to gated as well as real-time CMR. Special focus lied on the implementation of a spiral imaging protocol to resolve the beating heart of animals and humans in real time and free breathing. In order to achieve real-time CMR with high spatiotemporal resolution, k-space undersampling was performed. For this reason, efficient sampling strategies were developed with the aim to facilitate compressed sensing (CS) during image reconstruction. The applied CS approach successfully removed aliasing artifacts and yielded high-resolution cardiac image series. Image reconstruction was performed offline in all cases such that the images were not available immediately after acquisition at the scanner. Spiral real-time CMR could be performed in free breathing, which led to an acquisition time of less than 1 minute for a whole short-axis stack. At 3T, the results were compared to the gold standard of electrocardiogram-gated Cartesian CMR in breath hold, which revealed similar values for important cardiovascular functional and volumetric parameters. This paves the way to an application of the developed framework in clinical routine of CMR. In addition, the spiral real-time protocol was transferred to swallowing and speech imaging at 3T, and first images were presented. The results were of high quality and confirm the straightforward utilization of the spiral sequence in other fields of MRI. In general, the GSTF correction yielded high-quality images at both field strengths, 3T and 7T. Off-resonance related blurring was mitigated by applying non-Cartesian readout gradients of short duration. At 7T, however, B1-inhomogeneity led to image artifacts in some cases. All in all, this work demonstrated great advances in accelerating the MRI process by combining efficient, undersampled non-Cartesian k-space coverage with CS reconstruction. Trajectory correction using the GSTF can be implemented at any scanner model and enables non-Cartesian imaging with high image quality. Especially MRI of dynamic processes greatly benefits from the presented rapid imaging approaches. / In der vorliegenden Arbeit wurden Methoden der beschleunigten Magnetresonanztomographie (MRT) etabliert, welche auf nicht-kartesischer Datenaufnahme beruhen. Diese wurden insbesondere in der Herzbildgebung bei verschiedenen Magnetfeldstärken (3T und 7T) angewendet. Der Fokus lag auf der Entwicklung von hocheffizienten spiralförmigen k-Raum Trajektorien, mit dem Zweck sehr kurze Aufnahmezeiten zu ermöglichen. Zusätzlich wurde eine hybride k-Raum Trajektorie untersucht, die sogenannte "twisting radial lines (TWIRL)" k-Raum Trajektorie. Ungenauigkeiten des dynamischen Gradientensystems eines MRT Scanners resultieren in fehlerbehafteter k-Raum Abtastung während der Datenaufnahme. In der nicht-kartesischen Bildgebung kann dies letztendlich zu Artefakten im rekonstruierten Bild führen. Zusammen mit anderen Hemmnissen, wie beispielsweise einer komplexeren Bildrekonstruktion, sind sie verantwortlich dafür, dass noch immer mehrheitlich kartesische Bildgebungssequenzen in der klinischen Routine durchgeführt werden. Aus diesem Grund wurden die Übertragungsfunktionen der Gradientensysteme der verwendeten MRT Scanner (eng. "Gradient System Transfer Function (GSTF)") bestimmt und für k-Raum Trajektorienkorrekturen verwendet. Diese Korrektur wurde sowohl in der Bildrekonstruktion nach bereits erfolgter Datenaufnahme angewendet als auch im Rahmen einer Vorverstärkung bevor die Gradienten ausgespielt werden. Diese Vorverstärkung wurde als vollständig automatisierter Prozess implementiert und ermöglichte eine präzise Korrektur beliebig gewählter Gradientenfunktionen aller Schichtorientierungen. Auf diesem Wege konnten die durch Trajektorienfehler verursachten Bildartefakte kompensiert werden, was zu hoher Bildqualität in der nicht-kartesischen MRT Bildgebung führte. Des Weiteren wurde die Gradientenkorrektur durch Messungen der tatsächlich ausgespielten Gradientenformen validiert. Diese wiesen eine hohe Übereinstimmung mit den theoretisch zu erwarteten Gradientenformen auf. Darüber hinaus wurde gezeigt, dass die auf der Impulsantwort basierende, umfassende Gradientenkorrektur eine höhere Bildqualität ermöglicht als eine einfache Korrektur mittels globaler Zeitverschiebungen. Die entwickelten MRT Sequenzen wurden sowohl in der segmentierten als auch in der Echtzeit-Herzbildgebung angewendet. Im Speziellen lag der Fokus auf der Implementierung eines Protokolls für die spirale MRT Bildgebung, welche das schlagende Herz von Tieren und Menschen in Echtzeit und freier Atmung auflösen kann. Um Echtzeit-Herzbildgebung mit hoher räumlicher und zeitlicher Auflösung zu vereinen, wurde der k-Raum unterabgetastet. In diesem Zusammenhang wurden Strategien zur effizienten und komprimierten Datenaufnahme entwickelt, unter Anwendung der Modell-basierten "Compressed Sensing" (CS)-Technik. Diese Methode reduziert Aliasing-Artefakte in der Bildrekonstruktion von unterabgetasteten Daten und ermöglicht deshalb hochaufgelöste, dynamische Echtzeit-Bilderserien des schlagenden Herzens. Allerdings wurden die gemessenen Daten stets extern rekonstruiert, sodass die Bilder nicht unmittelbar nach der Aufnahme am MRT Scanner verfügbar waren. Die spirale Echtzeit-Herzbildgebung konnte in freier Atmung durchgeführt werden, was eine Messzeit aller Schichten in der kurzen Herzachse in unter 1 Minute ermöglichte. Bei 3T wurden die Ergebnisse mit dem Goldstandard der mittels eines Elektrokardiogramms segmentierten kartesischen Herzbildgebung im Atemstopp verglichen und es konnte gezeigt werden, dass wichtige funktionelle und volumetrische Herzparameter übereinstimmen. Dies ebnet den Weg zur Anwendung des entwickelten Protokolls in der klinischen Routine der Herzbildgebung am MRT. Darüber hinaus wurde das Protokoll in der Echtzeit-Bildgebung von Schlucken und Sprechen bei 3T getestet. Die Ergebnisse waren ebenfalls von hoher Qualität und bestätigen den unkomplizierten Transfer der spiralen Sequenz in andere Bereiche der MRT Bildgebung. Insgesamt lieferte die GSTF-Korrektur Bilder von hoher Qualität bei beiden Feldstärken, 3T und 7T. Eine durch off-Resonanz verursachte Bildunschärfe wurde durch kurze Auslesezeiten der nicht-kartesischen Gradienten abgeschwächt. Allerdings führte B1-Inhomogenität in manchen Fällen zu Bildartefakten bei 7T. Die vorliegende Arbeit stellt einen wesentlichen Beitrag zur Beschleunigung des MRT Bildgebungsprozesses dar, indem effiziente, unterabgetastete nicht-kartesische k-Raum Trajektorien mit der CS-Rekonstruktionstechnik kombiniert wurden. Trajektorien-Korrektur basierend auf der GSTF kann prinzipiell an jedem MRT Scanner implementiert werden und legt den Grundstein für nicht-kartesische Bildgebung mit hoher Bildqualität. Insbesondere die Bildgebung von dynamischen Prozessen profitiert von den hier vorgestellten beschleunigten Methoden zur Datenaufnahme.
54

Diagnose der linksventrikulären Hypertrophie bei Hämodialyse-PatientInnen anhand von Echokardiographie und EKG im Vergleich zum CMRI / Diagnosis and quantification of left ventricular mass by ecg and echocardiography compared to cardiac magnet resonance imaging in hemodialysis patients

Grebe, Sören January 2022 (has links) (PDF)
In der Gruppe der Hämodialyse-PatientInnen besteht ein deutlich erhöhtes Risiko an kardiovaskulären Ereignissen zu versterben. Korrespondierend hierzu weisen Hämodia-lyse-PatientInnen eine erhöhte Prävalenz an linksventrikulärer Hypertrophie (LVH) auf. Diese gilt als starker unabhängiger Risikofaktor für kardiovaskuläre Mortalität. Auf-grund der prognostischen Aussagekraft dient die Bewertung des linksventrikulären Massenindex (LVMI) sowie die Diagnose einer LVH vor allem in prospektiven Studien als ein bedeutendes Werkzeug zur Beurteilung des kardiovaskulären Risikos. Die Be-stimmung der LVH kann anhand von bildgebenden Verfahren (u.a. Echokardiographie, CMRI) oder dem EKG erfolgen. Die CMRI-Messung wird gegenwärtig als Goldstan-dard zur Messung der LVH betrachtet. Die 2D geführte M-mode-Methode der Echokardiographie zur Bestimmung der LVM zeichnet sich durch seine einfache und schnelle Durchführbarkeit aus und wird deshalb trotz präziserer Messverfahren wie dem 3D-Verfahren sowie diverser Einschränkungen weiterhin von der American Society of Echocardiography (ASE) als Screening-Methode und zur Untersuchung großer PatientInnenpopulationen empfohlen. Die empfohlene ASE-Formel überschätzt jedoch den LVMI nachweislich im Vergleich zum CMRI-Messverfahren. Die Überschätzung zeigte sich abhängig von der Höhe des LVMI. Es wird vermutet, dass die zunehmende Überschätzung Folge der geometrischen Grundan-nahmen ist, welche den LV vereinfachend als Ellipsoid mit konstantem L/D-Verhältnis annimmt. Dieses Verhältnis scheint sich jedoch bei zunehmender Herzgröße zu verän-dern, was wiederum zu einer Fehleinschätzung des LVMI führt. Die Teichholz (Th)-Formel korrigiert das L/D-Verhältnis mithilfe einer kurvilinearen Anpassung an den linksventrikulären Durchmesser und zeigte kürzlich in einer PatientInnengruppe mit Aor-tenstenose die geringste Tendenz der Überschätzung bei PatientInnen mit LVH. In der vorliegenden Studie wurden die echokardiographischen Formeln – ASE und Th – mit dem CMRI-Messverfahren verglichen. Beide Formeln zeigten eine deutliche Überschät-zung des LVMI. Die Th-Formel demonstrierte jedoch neben einer besseren Überein-stimmung zum CMRI, eine insgesamt geringere Überschätzung des LVMI sowie eine sukzessive Abnahme der Überschätzung mit zunehmendem LVMI. Zusammenfassend kann festgehalten werden, dass die Th-Formel der ASE-Formel in Bezug auf die Be-rechnung des LVMI bei Hämodialyse-PatientInnen insbesondere bei PatientInnen mit LVH überlegen ist. Weitere Studien sind jedoch erforderlich, um die Th-Formel in grö-ßeren Hämodialyse-PatientInnen-Kohorten mit höheren LVMI-Werten zu testen sowie um den prognostischen Wert der Th-Formel im Vergleich zur ASE-Formel zu ermitteln. Die klassischen EKG-Indices und -Scores zur Feststellung einer LVH wiesen, wie be-reits in anderen CMRI-Vergleichsstudien gezeigt, eine schlechte Sensitivität bei guter Spezifität auf. Aufgrund dessen verlor das EKG zunehmend an Bedeutung als Scree-ning-Untersuchung. In dieser Studie wurde der Versuch unternommen die Sensitivität durch zwei Lösungsansätze zu verbessern, einerseits durch die Kombination verschiede-ner EKG-Kriterien und andrerseits durch eine Adjustierung der EKG-Kriterien an den mittels Bioimpedanz gemessenen Fettmassenanteil. Die Kombination verschiedener EKG-Kriterien erzielte eine deutlich erhöhte Sensitivität von >70 %. Auch die Anpas-sung der EKG-Kriterien an den individuellen Fettmassenanteil könnte ein hilfreicher Lösungsansatz zur Verbesserung der Sensitivität bei Adipositas darstellen. / Left ventricular hypertrophy (LVH) is highly prevalent in patients on hemodialysis. LVH, as measured by the left ventricular mass index (LVMI), is a strong predictor of cardiovascular disease (CVD). Consequently, a reliable and valid method to detect LVH is needed for both clinical and scientific implications. For the assessment of left ventricular mass (LVM), cardiac magnetic resonance imaging (CMR) has been established as the most accurate and reproducible method. However, given its limited availability and high cost, CMR is not practical for clinical use in large-scale clinical studies. In contrast, the two-dimensional (2D) targeted M-mode transthoracic echocardiography (TTE) and ecg is preferred in the clinical context because of its widespread availability, low cost, simple handling, and extensive evidence base. Nevertheless, echocardiographic linear measurement and LVM calculation by cube function formulas have their own limitations. The current recommended formula from the American Society of Echocardiography (ASE) is based on special geometric assumptions, which may become inaccurate in the presence of asymmetric hypertrophy, eccentric remodeling, or distortion of left ventricular (LV) geometry and may lead to an incremental overestimation of LVMI. Teichholz et al. designed a formula that includes a volume-correcting function in order to minimize the error inter alia in patients with LVH. A recent CMR study investigating patients with aortic stenosis demonstrated that the Teichholz (Th) formula had a lower tendency to overestimate the value within a population with increased LVMI. Here, we investigated the performance of two echocardiographic formulas, ASE and Th, in calculating LVMI in patients on hemodialysis. TTE and CMR data for 95 hemodialysis patients who participated in the MiREnDa trial were analyzed. The LVMI was calculated by two-dimensional (2D) TTE-guided M-mode measurements employing the American Societ y of Echocardiography (ASE) and Teichholz (Th) formulas, which were compared to the reference method, CMR. LVH was present in 44% of patients based on LVMI measured by CMR. LVMI measured by echocardiography correlated moderately with CMR, ASE: r = 0.44 (0.34–0.62); Th: r = 0.44 (0.32–0.62). Compared to CMR, both echocardiographic formulas overestimated LVMI (mean ΔLVMI (ASE-CMR): 19.5 ± 19.48 g/m2, p < 0.001; mean ΔLVMI (Th-CMR): 15.9 ± 15.89 g/m2, p < 0.001). We found greater LVMI overestimation in patients with LVH using the ASE formula compared to the Th formula. Stratification of patients into CMR LVMI quartiles showed a continuous decrease in ΔLVMI with increasing CMR LVMI quartiles for the Th formula (p < 0.001) but not for the ASE formula (p = 0.772). Bland-Altman analysis showed that the Th formula had a constant bias independent of LVMI. Both methods had good discrimination ability for the detection of LVH (ROC-AUC: 0.819 (0.737–0.901) and 0.808 (0.723–0.892) for Th and ASE, respectively). The ASE and Th formulas overestimate LVMI in hemodialysis patients. However, the overestimation is less with the Th formula, particularly with increasing LVMI. The results suggest that the Th formula should be preferred for measurement of LVMI in chronic hemodialysis patients. Shown in other CMRI comparative studies the ECG indices and scores for detecting LVH had poor sensitivity with good specificity. Because of this, ECG became increasingly less important as a screening method. To improve the sensitivity by two approaches, on the one hand by combining different ECG criteria and on the other hand by adjusting the ECG criteria to the fat mass measured by bioimpedance. The combination of different ECG criteria achieved a significantly increased sensitivity of >70 %. The adjustment of the ECG criteria to the individual fat mass could also be a helpful approach to improve the sensitivity in obesity.
55

Accelerated inversion recovery MRI of the myocardium using spiral acquisition / Beschleunigte Inversion-Recovery MR-Bildgebung des Myokards mit spiralen Auslesezügen

Portmann, Johannes January 2023 (has links) (PDF)
This work deals with the acceleration of cardiovascular MRI for the assessment of functional information in steady-state contrast and for viability assessment during the inversion recovery of the magnetization. Two approaches are introduced and discussed in detail. MOCO-MAP uses an exponential model to recover dynamic image data, IR-CRISPI, with its low-rank plus sparse reconstruction, is related to compressed sensing. MOCO-MAP is a successor to model-based acceleration of parametermapping (MAP) for the application in the myocardial region. To this end, it was augmented with a motion correction (MOCO) step to allow exponential fitting the signal of a still object in temporal direction. Iteratively, this introduction of prior physical knowledge together with the enforcement of consistency with the measured data can be used to reconstruct an image series from distinctly shorter sampling time than the standard exam (< 3 s opposed to about 10 s). Results show feasibility of the method as well as detectability of delayed enhancement in the myocardium, but also significant discrepancies when imaging cardiac function and artifacts caused already by minor inaccuracy of the motion correction. IR-CRISPI was developed from CRISPI, which is a real-time protocol specifically designed for functional evaluation of image data in steady-state contrast. With a reconstruction based on the separate calculation of low-rank and sparse part, it employs a softer constraint than the strict exponential model, which was possible due to sufficient temporal sampling density via spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on dynamic and on inversion recovery data. Thus, motion correction is rendered unnecessary with it. IR-CRISPI was equipped with noise suppression via spatial wavelet filtering. A study comprising 10 patients with cardiac disease show medical applicability. A comparison with performed traditional reference exams offer insight into diagnostic benefits. Especially regarding patients with difficulty to hold their breath, the real-time manner of the IR-CRISPI acquisition provides a valuable alternative and an increase in robustness. In conclusion, especially with IR-CRISPI in free breathing, a major acceleration of the cardiovascular MR exam could be realized. In an acquisition of less than 100 s, it not only includes the information of two traditional protocols (cine and LGE), which take up more than 9.6 min, but also allows adjustment of TI in retrospect and yields lower artifact level with similar image quality. / Diese Arbeit behandelt die Beschleunigung der kardiovaskulären MRT zum Erfassen funktioneller Information bei Steady-State-Kontrast und zur Unter- suchung der Vitalität bei Wiederherstellung der Magnetisierung nach ihrer Inversion. Zwei Ansätze werden eingeführt und im Detail diskutiert: MOCO- MAP, welches ein exponentielles Modell nutzt, um dynamische Daten zu rekonstruieren, und IR-CRISPI, welches mit seinem “low-rank plus sparse"- Algorithmus mit Compressed Sensing verwandt ist. MOCO-MAP ist der Nachfolger der modellbasierten Beschleunigung des Parameter-Mappings (MAP) für die Anwendung im Bereich des Myokards. Hierzu wurde es mit einer Bewegungskorrektur (MOCO) versehen, um expo- nentielles Fitten eines unbewegten Objects in Zeitrichtung zu ermöglichen. Das Einbringen dieses physikalischen Vorwissens zusammen mit dem Erzwin- gen von Konsistenz mit den Messdaten wird dazu genutzt, iterativ eine Bildfolge aus Daten einer deutlich kürzeren Messung als herkömmlich zu rekonstruieren (< 3 s gegenüber ca. 10 s). Die Ergebnisse zeigen die Umsetz- barkeit der Methode sowie die Nachweisbarkeit von Delayed Enhancements im Myokard, aber deutliche funktionelle Abweichungen und Artefakte bereits aufgrund von kleinen Ungenauigkeiten der Bewegungskorrektur. IR-CRISPI geht aus CRISPI hervor, welches zur Auswertung von funk- tionellen Echtzeitdaten bei konstantem Kontrast dient. Mit der Rekon- struktion durch getrennte Berechnung von niedrigrangigem und dünnbe- setztem Matrixanteil wird hier bei der Datenrekonstruktion weniger stark eingeschränkt als bei einem strikten exponentiellen Modell. Die pirale Auf- nahmeweise erlaubt hierzu ausreichend effiziente k-Raumabdeckung. Die “low-rank plus sparse"-Rekonstruktion ist kompatibel mit dynamischen und mit Inversion-Recovery-Daten. Eine Bewegungskorrektur ist folglich nicht nötig. IR-CRISPI wurde mit einer Rauschunterdrückung durch räumliche Wavelet- Filterung versehen. Eine Studie, die 10 Patienten einschließt, zeigt die Eignung für die medizinische Anwendung. Der Vergleich mit herkömm- lichen Aufnahmetechniken lässt auf den gewonnenen diagnostischen Nutzen schließen. Besonders für Patienten, die Schwierigkeiten mit dem Luftanhal- ten haben, eröffnet diese Echtzeitaufnahmemethode eine wertvolle Alterna- tive und erhöhte Stabilität. Am Ende konnte gerade mittels IR-CRISPI eine bemerkenswerte Beschleu- nigung der kardiovaskulären MR-Untersuchung verwirklicht werden. Trotz der kurzen Aufnahmezeit von weniger als 100 s für den kompletten linken Ven- trikel schließt es nicht nur die Information zweier herkömmlicher Protokolle mit ein (Cine und LGE), die zusammen mehr als 9,6 min dauern, sondern es erlaubt zusätzlich auch das Einstellen der TI-Zeit im Nachhinein und liefert Ergebnisse mit geringerem Artefaktlevel bei ähnlicher Bildqualität
56

Temporal predictability of threat: Evaluation of differential involvement of amygdala and BNST, and relevance for therapy response prediction in spider phobia / Zeitliche Vorhersagbarkeit von Bedrohung: Evaluation der unterschiedlichen Aktivierung von Amygdala und BNST sowie die Relevanz für die Vorhersagbarkeit von Therapieerfolg bei der Spinnenphobie

Siminski, Niklas January 2023 (has links) (PDF)
Predictability of threat is one of the key modulators of neural activity in fear and anxiety-related threat processes and there is a considerable number of studies focusing on the exact contribution of centromedial amygdala and Bed nucleus of stria terminalis (BNST) in animals as well as in humans. In this research field, some studies already investigated the differential involvement of both areas during temporally predictable and unpredictable threat processes in humans. However, these studies showed several limitations e.g. small sample size, no predictable threat conditions, no separation of anticipation and confrontation processes, which should be addressed in future studies. Furthermore, evidence for group-based inter-individual differences of amygdala and BNST activity during predictable and unpredictable threat processes have not been studied extensively. Several studies suggest a relevant role of the amygdala and BNST activity in phobic processes in patients with specific phobia, but no study so far has investigated the exact contribution of centromedial amygdala (CM) and BNST during temporally predictable and unpredictable threat processes in specific phobia. This thesis consisted of three studies and aimed to evaluate the exact contribution of CM and BNST during temporally predictable and unpredictable threat anticipation and confrontation with the use of an optimized functional magnetic resonance imaging (fMRI) paradigm, which aimed to solve methodological limitations of recent studies. Study 1 used a large sample of healthy participants who were grouped based on NPSR1 genotype, and study 2 and study 3 used a sample of patients with spider phobia. In sum, the results of all three studies indicated, that BNST is more relevant for anticipation processes as compared to the CM. Contrary, during the confrontation phase the CM displays a greater relevance for threat confrontation processes. In recent years, various studies have investigated the extent to which treatment success can be predicted in patients with anxiety disorders based on pre-treatment fMRI activity. Therefore, this was investigated for the first time in study 3 in patients with spider phobia during temporally predictable and unpredictable threat processes. Results indicated that independent of temporal predictability lower anterior cingulate cortex (ACC) activity during threat anticipation and engaged BNST during threat confrontation might be benefitting factors for successful therapy response in spider phobia. / Die Vorhersagbarkeit der Bedrohung ist einer der wichtigsten Modulatoren der neuronalen Aktivität bei angst- und furchtbezogenen Bedrohungsprozessen, und es gibt eine beträchtliche Anzahl von Studien, die sich mit der unterschiedlichen Beteiligung der zentromedialen Amygdala (CM) und des Bed nucleus of stria terminalis (BNST) während dieser Prozesse sowohl bei Tieren als auch beim Menschen beschäftigen. In diesem Forschungsfeld untersuchten bereits einige Studien die exakte Beteiligung beider Areale während zeitlich vorhersehbarer und unvorhersehbarer Bedrohungsprozesse beim Menschen. Diese Studien wiesen jedoch einige Limitationen auf (z.B. geringe Stichprobengröße, keine vorhersagbaren Bedrohungsbedingungen, gemeinsame Analyse der Aktivierung über Antizipations- und Konfrontationsphasen hinweg), die in zukünftigen Studien verbessert werden sollten. Zudem gibt es bisher wenige Studien, welche die unterschiedliche Beteiligung der Amygdala und des BNST während Bedrohungsprozessen auf Grundlage gruppenbasierter inter-individueller Unterschiede untersucht haben. Mehrere Studien deuten auf eine erhöhte Aktivierung sowohl der Amygdala als auch des BNST während phobischer Angstprozesse bei Patient*Innen mit einer spezifischen Phobie hin. Allerdings hat bisher jedoch noch keine Studie die Aktivierung der CM und des BNST während zeitlich vorhersagbarer und unvorhersagbarer phobischer Bedrohungsprozesse bei Patient*Innen direkt verglichen. Unter Verwendung eines optimierten funktionelle Magnetresonanztomographie (fMRT)-Paradigmas, das darauf abzielte, methodische Probleme der bisherigen Studien zu lösen, wurde in dieser Arbeit die unterschiedliche Aktivierung von CM und BNST während zeitlich vorhersehbarer und unvorhersehbarer Bedrohungsantizipation und -konfrontation in einer großen Stichprobe gesunder Teilnehmer, die anhand des NPSR1-Genotyps gruppiert wurden (Studie 1), und Patient*Innen mit einer Spinnenphobie untersucht (Studie 2 und Studie 3). In Summe zeigten die Ergebnisse aller drei Studien, dass im Vergleich zur CM der BNST für Antizipationsprozesse relevanter ist. Hingegen zeigte die CM in der Konfrontationsphase mit einer Bedrohung eine größere Aktivierung als der BNST. In den letzten Jahren haben verschiedene Studien untersucht, inwieweit der Behandlungserfolg bei Patient*Innen mit einer Angststörung anhand der fMRT-Aktivität vor der Behandlung vorhergesagt werden kann. Daher wurde in Studie 3 dies erstmals bei Patient*Innen mit einer Spinnenphobie während zeitlich vorhersehbarer und unvorhersehbarer Bedrohungsprozesse untersucht. Die Ergebnisse deuteten darauf hin, dass eine geringere Aktivität im anterioren cingulären Cortex (ACC) während phobischen Antizipationsprozessen und eine höhere Aktivierung im BNST während der Konfrontation mit phobischen Stimuli günstige Faktoren für den Therapieerfolg bei Spinnenphobie sein könnten.
57

Variational networks in magnetic resonance imaging - Application to spiral cardiac MRI and investigations on image quality / Variational Networks in der Magnetresonanztomographie - Anwendung auf spirale Herzbildgebung und Untersuchungen zur Bildqualität

Kleineisel, Jonas January 2024 (has links) (PDF)
Acceleration is a central aim of clinical and technical research in magnetic resonance imaging (MRI) today, with the potential to increase robustness, accessibility and patient comfort, reduce cost, and enable entirely new kinds of examinations. A key component in this endeavor is image reconstruction, as most modern approaches build on advanced signal and image processing. Here, deep learning (DL)-based methods have recently shown considerable potential, with numerous publications demonstrating benefits for MRI reconstruction. However, these methods often come at the cost of an increased risk for subtle yet critical errors. Therefore, the aim of this thesis is to advance DL-based MRI reconstruction, while ensuring high quality and fidelity with measured data. A network architecture specifically suited for this purpose is the variational network (VN). To investigate the benefits these can bring to non-Cartesian cardiac imaging, the first part presents an application of VNs, which were specifically adapted to the reconstruction of accelerated spiral acquisitions. The proposed method is compared to a segmented exam, a U-Net and a compressed sensing (CS) model using qualitative and quantitative measures. While the U-Net performed poorly, the VN as well as the CS reconstruction showed good output quality. In functional cardiac imaging, the proposed real-time method with VN reconstruction substantially accelerates examinations over the gold-standard, from over 10 to just 1 minute. Clinical parameters agreed on average. Generally in MRI reconstruction, the assessment of image quality is complex, in particular for modern non-linear methods. Therefore, advanced techniques for precise evaluation of quality were subsequently demonstrated. With two distinct methods, resolution and amplification or suppression of noise are quantified locally in each pixel of a reconstruction. Using these, local maps of resolution and noise in parallel imaging (GRAPPA), CS, U-Net and VN reconstructions were determined for MR images of the brain. In the tested images, GRAPPA delivers uniform and ideal resolution, but amplifies noise noticeably. The other methods adapt their behavior to image structure, where different levels of local blurring were observed at edges compared to homogeneous areas, and noise was suppressed except at edges. Overall, VNs were found to combine a number of advantageous properties, including a good trade-off between resolution and noise, fast reconstruction times, and high overall image quality and fidelity of the produced output. Therefore, this network architecture seems highly promising for MRI reconstruction. / Eine Beschleunigung des Bildgebungsprozesses ist heute ein wichtiges Ziel von klinischer und technischer Forschung in der Magnetresonanztomographie (MRT). Dadurch könnten Robustheit, Verfügbarkeit und Patientenkomfort erhöht, Kosten gesenkt und ganz neue Arten von Untersuchungen möglich gemacht werden. Da sich die meisten modernen Ansätze hierfür auf eine fortgeschrittene Signal- und Bildverarbeitung stützen, ist die Bildrekonstruktion ein zentraler Baustein. In diesem Bereich haben Deep Learning (DL)-basierte Methoden in der jüngeren Vergangenheit bemerkenswertes Potenzial gezeigt und eine Vielzahl an Publikationen konnte deren Nutzen in der MRT-Rekonstruktion feststellen. Allerdings besteht dabei das Risiko von subtilen und doch kritischen Fehlern. Daher ist das Ziel dieser Arbeit, die DL-basierte MRT-Rekonstruktion weiterzuentwickeln, während gleichzeitig hohe Bildqualität und Treue der erzeugten Bilder mit den gemessenen Daten gewährleistet wird. Eine Netzwerkarchitektur, die dafür besonders geeignet ist, ist das Variational Network (VN). Um den Nutzen dieser Netzwerke für nicht-kartesische Herzbildgebung zu untersuchen, beschreibt der erste Teil dieser Arbeit eine Anwendung von VNs, welche spezifisch für die Rekonstruktion von beschleunigten Akquisitionen mit spiralen Auslesetrajektorien angepasst wurden. Die vorgeschlagene Methode wird mit einer segmentierten Rekonstruktion, einem U-Net, und einem Compressed Sensing (CS)-Modell anhand von qualitativen und quantitativen Metriken verglichen. Während das U-Net schlecht abschneidet, zeigen die VN- und CS-Methoden eine gute Bildqualität. In der funktionalen Herzbildgebung beschleunigt die vorgeschlagene Echtzeit-Methode mit VN-Rekonstruktion die Aufnahme gegenüber dem Goldstandard wesentlich, von etwa zehn zu nur einer Minute. Klinische Parameter stimmen im Mittel überein. Die Bewertung von Bildqualität in der MRT-Rekonstruktion ist im Allgemeinen komplex, vor allem für moderne, nichtlineare Methoden. Daher wurden anschließend forgeschrittene Techniken zur präsizen Analyse von Bildqualität demonstriert. Mit zwei separaten Methoden wurde einerseits die Auflösung und andererseits die Verstärkung oder Unterdrückung von Rauschen in jedem Pixel eines untersuchten Bildes lokal quantifiziert. Damit wurden lokale Karten von Auflösung und Rauschen in Rekonstruktionen durch Parallele Bildgebung (GRAPPA), CS, U-Net und VN für MR-Aufnahmen des Gehirns berechnet. In den untersuchten Bildern zeigte GRAPPA gleichmäßig eine ideale Auflösung, aber merkliche Rauschverstärkung. Die anderen Methoden verhalten sich lokal unterschiedlich je nach Struktur des untersuchten Bildes. Die gemessene lokale Unschärfe unterschied sich an den Kanten gegenüber homogenen Bildbereichen, und Rauschen wurde überall außer an Kanten unterdrückt. Insgesamt wurde für VNs eine Kombination von verschiedenen günstigen Eigenschaften festgestellt, unter anderem ein guter Kompromiss zwischen Auflösung und Rauschen, schnelle Laufzeit, und hohe Qualität und Datentreue der erzeugten Bilder. Daher erscheint diese Netzwerkarchitektur als ein äußerst vielversprechender Ansatz für MRT-Rekonstruktion.
58

Beurteilung subklinischer akuter zellulärer Abstoßungsreaktion nach Herztransplantation: Vergleich der kardialen Magnetresonanztomographie mit der endomyokardialen Biopsie

Krieghoff, Christian 26 September 2016 (has links) (PDF)
Für Patienten mit fortgeschrittener Herzinsuffizienz ist die Herztransplantation die einzige kurative Therapieoption. Die akute Abstoßungsreaktion ist ein entscheidender Faktor der Mortalität nach Transplantation. Zur Früherkennung einer Abstoßungsreaktion gilt nach wie vor die Endomyokardbiopsie als Goldstandard. Diese stellt jedoch ein invasives Verfahren mit seltenen, aber potentiell schwerwiegenden Komplikationen dar. In der vorliegenden Studie wurde die diagnostische Wertigkeit der kardialen Magnetresonanztomographie zur Detektion der Abstoßungsreaktion nach Herztransplantation untersucht. Als Referenz diente die Myokardbiopsie mit histologischer Beurteilung nach dem Schema der International Society of Heart and Lung Transplantation (ISHLT). Insbesondere bei Kombination mehrerer Parameter konnte ein hoher negativ prädiktiver Wert zum Ausschluss einer akuten Abstoßungsreaktion erzielt werden. Dagegen waren Spezifität und positiv prädiktiver Wert zu gering, um eine Therapie-Änderung alleine auf Basis eines positiven MRT-Befundes zu rechtfertigen.
59

Untersuchung von Trainingseffekten bei der Verwendung einer auditorischen P300-basierten EEG Gehirn-Computer Schnittstelle mittels fMRI Analyse / Investigation of training effects of a P300-based EEG brain-computer interface using fMRI analysis

Leinfelder, Teresa January 2022 (has links) (PDF)
In dieser Dissertation untersuchten wir die neuronalen Korrelate des Training-Effektes einer auditorischen P300 Gehirn-Computer Schnittstelle mittels fMRI Analyse in einem prä-post Design mit zehn gesunden Testpersonen. Wir wiesen in drei Trainings-sitzungen einen Trainingseffekt in der EEG-Analyse der P300 Welle nach und fanden entsprechende Kontraste in einer prä-post Analyse von fMRI Daten, wobei in allen fünf Sitzungen das gleiche Paradigma verwendet wurde. In der fMRI Analyse fanden wir fol-gende Ergebnisse: in einem Target-/ Nichttarget Kontrast zeigte sich verstärkte Aktivie-rung in Generatorregionen der P300 Welle (temporale und inferiore frontale Regionen) und interessanterweise auch in motorassoziierten Arealen, was höhere kognitiver Pro-zesse wie Aufmerksamkeitslenkung und Arbeitsspeicher widerspiegeln könnte. Der Kon-trast des Trainingseffektes zeigte nach dem Training einen stärkeren Rebound Effekt im Sinne einer verstärkten Aktivierung in Generatorregionen der P300 Welle, was eine ver-besserte Erkennung und Prozessierung von Target-Stimuli reflektieren könnte. Eine Ab-nahme von Aktivierung in frontalen Arealen in diesem Kontrast könnte durch effizientere Abläufe kognitiver Prozesse und des Arbeitsgedächtnis erklärt werden. / In this dissertation we investigated the neuronal correlates of the training effect of an auditory P300-based brain-computer interface using fMRI analysis in a prae-post de-sign in a group of ten healthy probands. We showed a training effect during three training sessions with EEG analysis of the P300 wave and found corresponding contrasts in a prae-post analysis of fMRI data, while using the same paradigma in all sessions. In the fMRI analysis we found the following results: in a target / nontarget contrast we found enhancement of activation in generator regions of the P300 wave such as temporal and inferior frontal areas and interestingly also in motor associated areas which could reflect higher cognitive processes such as attention and working memory. In the contrast of the effects of training we found a stronger rebound effect as a correlate of stronger activation after training in generator regions of P300, possibly reflecting better discrimination and processing of stimuli. The decrease of activation in frontal areas in this contrast could be explained by increased efficiency of cognitive processing and working memory through training.
60

Moderators of exposure-based treatment outcome in anxiety disorders: an fMRI approach / Moderatoren des Expositionserfolgs bei Angststörungen: ein fMRT-basierter Ansatz

Seeger, Fabian Reinhard January 2023 (has links) (PDF)
Even though exposure-based cognitive behavioral therapy (CBT) constitutes a first-line treatment for anxiety disorders, a substantial proportion of patients does not respond in a clinically significant manner. The identification of pre-treatment patient characteristics that are associated with treatment outcome might aid in improving response rates. Therefore, the present doctoral thesis aimed at investigating moderators of treatment outcome in anxiety disorders: first, we investigated the neural correlates of comorbidity among primary panic disorder/agoraphobia (PD/AG) and secondary social anxiety disorder (SAD) moderating treatment outcome towards exposure-based CBT. Second, pre-treatment functional resting-state connectivity signatures of treatment response in specific phobia were studied. Within the first study, we compared PD/AG patients with or without secondary SAD regarding their clinical and neurofunctional outcome towards a manualized CBT treatment focusing on PD/AG symptoms. Prior to treatment, PD/AG+SAD compared to PD/AG-SAD patients exhibited a specific neural signature within the temporal lobe, which was attenuated to the level of PD/AG-SAD patients afterwards. CBT was equally effective in both groups. Thus, comorbidity among those two anxiety disorders did not alter treatment outcome substantially. This might be due to the high overlap of shared pathophysiological features within both disorders. In the second study, we assessed pre-treatment functional resting-state connectivity within a sample of spider phobic patients that were treated with massed in virtuo exposure. We found responders already prior to treatment to be characterized by stronger inhibitory frontolimbic connectivity as well as heightened connectivity between the amygdala and regions related to the ventral visual stream. Furthermore, patients demonstrating high within-session extinction exhibited pronounced intrinsic prefrontal connectivity. Our results point to responders exhibiting a brain prepared for the mechanism of action of exposure. Taken together, results highlight the major impact of pre-treatment characteristics on treatment outcome. Both, PD/AG+SAD patients as well as responders within the SpiderVR study exhibited heightened activation or connectivity within the ventral visual pathway and the amygdala. Pronounced visual processing together with enhanced executive control and emotion regulation seem to constitute a fruitful soil for successful exposure. The results provide starting points for personalized treatment approaches in order to improve treatment success in the anxiety disorders. Future studies are needed to investigate the benefit of neuroscientifically informed CBT augmentation strategies such as repetitive transcranial magnetic stimulation. / Obwohl expositionsbasierte kognitive Verhaltenstherapie (KVT) bei Angststörungen als Behandlungsmethode der Wahl gilt, profitieren viele Patient*innen nicht in klinisch bedeutsamer Weise. Durch die Identifikation von Patient*innenmerkmalen mit Bezug zum Therapieerfolg bereits vor Behandlungsbeginn könnte das Therapieansprechen verbessert werden. Die vorliegende Arbeit hat sich daher die Identifikation von Moderatoren des Behandlungserfolgs zum Ziel gesetzt. Zunächst untersuchten wir die neuronalen Korrelate einer Komorbidität zwischen Panikstörung/Agoraphobie und sozialer Phobie (SAD) und deren moderierenden Einfluss auf den Behandlungserfolg. Daneben wurden Merkmale der funktionellen Ruhe-Konnektivität, die mit dem Therapieerfolg bei spezifischer Phobie in Zusammenhang stehen, untersucht. In der ersten Studie untersuchten wir Panikpatient*innen mit und ohne sekundäre SAD in Bezug auf ihr klinisches und neurofunktionelles Behandlungsergebnis unter Anwendung einer manualisierten KVT. Panikpatient*innen mit sekundärer SAD zeigten vor Therapiebeginn im Vergleich zu Panikpatient*innen ohne SAD ein spezifisches Aktivierungsmuster im Temporallappen, welches sich nach der Behandlung dem der Patient*innen ohne SAD anglich. Die KVT war in beiden Gruppen gleich erfolgreich. Die Ergebnisse deuten darauf hin, dass eine Komorbidität hier keinen substanziellen Einfluss auf den Therapieerfolg hat. Dies könnte in der überlappenden Pathophysiologie begründet sein. In der zweiten Studie untersuchten wir die funktionelle Ruhe-Konnektivität bei Spinnenphobiker* innen, die anschließend mit einer massierten Expositionstherapie in virtueller Realität behandelt wurden. Therapie-Responder waren hierbei durch eine verstärkte inhibitorische fronto-limbische Konnektivität vor Therapiebeginn sowie eine ebenfalls verstärkte Kopplung von Amygdala und Regionen des ventralen Objekterkennungspfades gekennzeichnet. Zugleich wiesen Patient*innen mit hoher within-session Extinktion eine verstärkte intrinsische präfrontale Konnektivität auf. Die Ergebnisse deuten auf eine verbesserte neuronale Vorbereitung auf inhibitorisches Lernen bei Patient*innen mit gutem Therapieansprechen hin. Zusammenfassend unterstreichen die Ergebnisse die Relevanz von Patient*inneneigenschaften für den Therapieerfolg. Sowohl Panikpatient*innen mit sekundärer SAD als auch die Responder der SpiderVR-Studie wiesen erhöhte Aktivierung bzw. Konnektivität zwischen der Amygdala und dem ventralem Objekterkennungspfad auf. Zusammen mit einer stärkeren exekutiven Kontrolle und Emotionsregulation scheint eine verstärkte visuelle Verarbeitung einem guten Therapieerfolg dienlich zu sein. Die Behandlungsergebnisse könnten auf Basis neurowissenschaftlicher Erkenntnisse durch den Einsatz zusätzlicher Methoden wie der repetitiven transkraniellen Magnetstimulation verbessert werden.

Page generated in 0.0879 seconds