• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 30
  • 12
  • 12
  • 2
  • Tagged with
  • 88
  • 54
  • 49
  • 30
  • 30
  • 30
  • 24
  • 17
  • 12
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Solcellers effektivitet vid integrerat eller applicerat montage / Solar cells efficiency of integrated or applicated montage

Larsson, August January 2019 (has links)
Sweden has a climate target to get a total renewable electricity production by 2040, in order to succeed with the goal, the proportion of solar energy needs to increase. Increased environmental awareness and increased profitability of solar cells have led to an increase. A new way of attaching solar cells to buildings is by integrating them into building materials. A solution that optimizes material, makes the installation easier and creates better design. Today, there is concern that the temperature of the solar cells may become very high as their cooling decreases. The consequences of an increased temperature in the solar cells is that the efficiency of the electricity production decreases. The purpose of this study is therefore to increase understanding of the influence of modular temperature on electricity production. The aim of the study was to find out how much electricity production [kWh/m2, year] varies in solar cells depending on whether they are applied to buildings or if they are integrated into building materials for solar cells placed in Nordic climate. In order to do this, a calculation model was built in Simulink Matlab to calculate how the modular temperature varied during the varying weather conditions that occur during a year in Gothenburg. Air flow in the gap is created by self-convection. Some periods blew the wind into the gap in the ceiling and then the wind was also assumed to contribute with an air flow. In order to describe the self-conception, a theoretical relationship was established, to describe how the wind influenced the airflow of the roof, a connection from an experimental study was used. With the help of the calculated calculation model, it was possible to determine how much electricity production varied during integrated or applied assembly in Gothenburg. The result found was an increase of 4% for ceiling-mounted and 2% respectively for wall-mounted solar cells with applied mounting compared to integrated installation. The model was also tested for a warmer and a colder climate, Rome and Luleå. The conclusion was that building-applied solar cells can increase electricity production by up to 4% for solar cells on roofs and up to 2% for solar cells placed on the wall in Nordic climate compared to fully integrated solar cells, an air gap is therefore more effective for solar cells placed on roofs than on the wall. It was found that in warmer climates, as in Rome, the corresponding increase in electricity production was about double that for both roof and wall, an air gap is therefore more efficient in a warmer climate.
22

Thinning and turbulence in aqueous films

Winkler, Michael January 2011 (has links)
This thesis covers the topic ”Thinning and Turbulence in Aqueous Films”. Experimental studies in two-dimensional systems gained an increasing amount of attention during the last decade. Thin liquid films serve as paradigms of atmospheric convection, thermal convection in the Earth’s mantle or turbulence in magnetohydrodynamics. Recent research on colloids, interfaces and nanofluids lead to advances in the developtment of micro-mixers (lab-on-a-chip devices). In this project a detailed description of a thin film experiment with focus on the particular surface forces is presented. The impact of turbulence on the thinning of liquid films which are oriented parallel to the gravitational force is studied. An experimental setup was developed which permits the capturing of thin film interference patterns under controlled surface and atmospheric conditions. The measurement setup also serves as a prototype of a mixer on the basis of thermally induced turbulence in liquid thin films with thicknesses in the nanometer range. The convection is realized by placing a cooled copper rod in the center of the film. The temperature gradient between the rod and the atmosphere results in a density gradient in the liquid film, so that different buoyancies generate turbulence. In the work at hand the thermally driven convection is characterized by a newly developed algorithm, named Cluster Imaging Velocimetry (CIV). This routine determines the flow relevant vector fields (velocity and deformation). On the basis of these insights the flow in the experiment was investigated with respect to its mixing properties. The mixing characteristics were compared to theoretical models and mixing efficiency of the flow scheme calculated. The gravitationally driven thinning of the liquid film was analyzed under the influence of turbulence. Strong shear forces lead to the generation of ultra-thin domains which consist of Newton black film. Due to the exponential expansion of the thin areas and the efficient mixing, this two-phase flow rapidly turns into the convection of only ultra-thin film. This turbulence driven transition was observed and quantified for the first time. The existence of stable convection in liquid nanofilms was proven for the first time in the context of this work. / Diese Diplomarbeit behandelt das Thema ”Dünnung und Turbulenz in wässrigen Filmen”. Experimente in zweidimensionalen Systemen erfuhren in den vergangenen Jahren zunehmend an Aufmerksamkeit. Dünne Flüssigkeitsschichten dienen als Modell für atmosphärische Konvektion, thermische Konvektion im Erdmantel oder Turbulenz in der Magnetohydrodynamik. Aktuelle Forschung im Bereich der Kolloide, Grenzflächen und Nanofluidik führt zu Fortschritten in der Entwicklung von Mikromixern (”lab-on-a-chip”). In diesem Projekt wird eine detaillierte Beschreibung eines Dünnfilmexperiments mit Fokus auf die besonderen Oberflächenkräfte vorgestellt. Die Auswirkung der Turbulenz auf die Dünnung von parallel zur Gravitationskraft orientierten Flüssigkeitsschichten wurde untersucht. Es wurde ein Experiment entwickelt, welches die Aufnahme von Dünnschichtinterferenzmustern unter kontrollierten Oberflächenbedingungen und Atmosphäre erlaubt. Der Messaufbau dient auch als Prototyp eines Mixers auf Basis von thermisch induzierter Turbulenz in Flüssigkeitsfilmen mit Dicken im Nanometerbereich. Die Konvektion wird durch das Platzieren eines gekühlten Kupferstabs in der Mitte des Films realisiert. Der Temperaturgradient zwischen Stab und äußerer Atmosphäre resultiert in einem Dichtegradienten in dem flüssigen Film, sodass durch unterschiedliche Auftriebskräfte Turbulenz erzeugt wird. In der vorliegenden Arbeit ist die thermisch getriebenen Konvektion an Hand eines neu entwickelten Verfahrens (Cluster Imaging Velocimetry - CIV) zur Ermittlung des strömungsrelevanten Vektorfelder (Geschwindigkeit und Deformation) charakterisiert worden. Auf Basis dieser Erkenntnisse wurde die im Experiment vorherrschende Strömung in Hinsicht auf ihre Mischungseigenschaften im Vergleich zu theoretischen Modellen untersucht und die Mischungseffizienz berechnet. Die gravitationsgetriebene Ausdünnung der Flüssigkeitsschicht unter Einfluss der Turbulenz wurde analysiert. Durch starke Scherkräfte kommt es lokal zur Bildung ultradünner Domänen bestehend aus ”Newton black film”. Diese Zweiphasenströmung geht durch das exponentielle Ausdehnen der dünnen Bereiche und die effiziente Mischung sehr schnell in eine Konvektion von ausschließlich ultradünnem Film im Gleichgewichtszustand über. Dieser turbulenzgetriebene Übergang wurde zum ersten Mal beobachtet und quantifiziert. Die Existenz stabiler Konvektion in flüssigen Nanofilmen ist zum ersten Mal im Rahmen dieser Arbeit belegt worden.
23

Analyse konvektiver Transportprozesse während der Magnetoelektrolyse

Mühlenhoff, Sascha 13 August 2012 (has links) (PDF)
Untersuchung konvektiver Transportprozesse innerhalb einer auf der Lorentz-Kraft basierenden Strömung während der elektrolytischen Abscheidung.
24

Effect of melt convection on microstructure evolution of peritectic Nd-Fe-B and Ti-Al alloys

Biswas, Kaushik 25 September 2008 (has links) (PDF)
In dieser Arbeit wurde der Einfluss der Schmelzkonvektion auf das erstarrende Gefüge von peritektischen Nd-Fe-B – und TiAl-Legierungen mit Hilfe neuartiger Methoden untersucht. Da die magnetischen und mechanischen Eigenschaften dieser technisch relevanten Legierungen stark vom Gefüge und insbesondere vom Volumenanteil der properitektischen Phase abhängen, sind diese Untersuchungen von großem Interesse. Auf der Basis der numerischen Simulationen der Schmelzkonvektionsmoden und des elektromagnetischen Problems in einer induktiv beheizten Schmelze, die am Forschungszentrum Dresden-Rossendorf durchgeführt wurden, wurden am IFW Dresden neuartige Versuchsaufbauten entwickelt, die die Modifizierung der Konvektion in einer Metallschmelze ermöglichen. Dies sind ein Aufbau zur erzwungenen Schmelzrotation in einem Tiegel und eine modifizierte Floating-Zone-Anlage. Die erzwungene Schmelzrotation, bei der der Schmelztiegel mit einer definierten Frequenz rotiert, führt in Übereinstimmung mit der Simulation zu einer starken Reduzierung der Konvektion in Abhängigkeit von der Frequenz. Diese Methode wurde auf Nd-Fe-B-Legierungen angewendet mit dem Ziel, die Bildung der unerwünschten weichmagnetischen Eisenphase zu unterdrücken bzw. deren Volumenanteil zu reduzieren. Im Ergebnis konnte der Volumenanteil der properitektischen Phase mit diesem Verfahren um 38.5 % reduziert werden. Das dendritische Gefüge wurde einer ausführlichen statistischen Analyse unterzogen, bei der die Abstände der sekundären Dendritenarme (SDAS) gemessen wurden. Es konnte gezeigt werden, dass die SDAS sich mit steigender Frequenz der Tiegelrotation, was einer reduzierten Schmelzkonvektion entspricht, verringern. Die Verringerung des Volumenanteils der properitektischen Eisenphase und der SDAS wird mit dem reduzierten konvektiven Massentransport unter reduzierter Schmelzkonvektion erklärt. Starke interdendritische Strömung reduziert die Dicke der Diffusionsgrenzschicht um die properitektische Phase. Dadurch wird der Stofftransport durch die Grenzschicht erleichtert. Kleinere Dendritenarme werden in die Schmelze zurückgeschmolzen, wodurch sich der Abstand zwischen den verbleibenden Dendritenarmen vergrößert. Eine Floating-Zone-Anlage, die das tiegelfreie Prozessieren von Metallschmelzen erlaubt wurde so modifiziert, dass mit Hilfe eines Doppelspulensystems eine zusätzliche wohl definierte elektromagnetische Kraft eingebracht wird, über die eine sehr intensive (Zweiphasenrührer in Parallelschaltung) bzw. stark verringerte Strömung (Doppelspule in Reihenschaltung) in der Schmelze eingestellt werden kann. Die experimentellen Ergebnisse der Untersuchungen am Nd-Fe-B-System mit der Doppelspule in Reihenschaltung zeigten, dass sich bei einem optimalen Spulenabstand von 5,1 mm die geringste Schmelzkonvektion ergab, wobei der Anteil des a-Eisen-Volumenanteils weiter verringert werden konnte. Im Gegensatz dazu wurde mit dem Zweiphasenrührer in Parallelschaltung eine sehr starke Schmelzkonvektion mit einem maximalen Volumenanteil der a-Eisen-Phase eingestellt, wobei durch die starke Rührung ein Wechsel der Morphologie von dendritisch zu globular zu beobachten war. Die Untersuchungen zum Einfluss der starken Schmelzkonvektion wurden auf ein weiteres peritektisch erstarrendes System ausgedehnt, um eine generalisierte Aussage zum Einfluss der Konvektion auf Gefüge und Eigenschaften peritektisch erstarrender Legierungen zu erhalten. Die ausgewählte Ti45Al55 - Legierung erstarrte unter starker Schmelzkonvektion ebenfalls globulitisch, wobei Reste dendritisch erstarrter properitektischer Phase gefunden wurden. Der Volumenanteil der properitektischen Phase steigt dabei mit zunehmender Rührwirkung an. Der Wechsel der Morphologie von dendritisch zu globular/dendritisch kann mit sphärischem Wachstum oder Fragmentierung der Dendritenarme erklärt werden. Die mechanischen Eigenschaften unter unterschiedlicher Schmelzkonvektion erstarrter Ti45Al55 – Legierung wurden bei Druckversuchen untersucht. Es wurde eine signifikant höhere plastische Verformbarkeit an der unter starker Schmelzkonvektion erstarrten Ti45Al55 – Legierung gefunden. Dies wird der isotropen spherischen Morphologie der lamellaren a2/g-Phase zugeordnet, während die anisotrope Orientierung der dendritisch- lamellaren Phase unerwünschte plastische Eigenschaften zeigt. Die Untersuchungen des Einflusses der Schmelzkonvektion auf das Gefüge peritektisch erstarrender Legierungen zeigten, dass ein maßgeschneidertes Gefüge durch optimale Wahl der Schmelzkonvektion möglich ist und damit magnetische bzw. mechanische Eigenschaften verbessert werden können. Die Kontrolle der Schmelzkonvektion ist daher ein geeignetes Mittel gewünschte Gefüge und Eigenschaften in Abhängigkeit von den Prozessabläufen einzustellen. / In this work, the effect of melt convection on the microstructure evolution of peritectic Nd-Fe-B and Ti-Al alloy systems was studied using novel techniques. The microstructural formation including the change in volume fraction and morphology of the properitectic phase influences the magnetic and mechanical properties for the Nd-Fe-B and Ti-Al alloy systems, respectively. On the basis of numerical simulations by the research group of Dr. Gunter Gerbeth from Department of Magnetohydrodynamics, Forschungszentrum Dresden-Rossendorf, two types of specially designed facilities were developed where melt convection can be altered by changing a number of parameters. These are: forced rotation facility and modified floating zone facility. According to the numerical simulation, an additional crucible rotation suppresses the internal melt motion significantly during forced rotation experiments, where the molten alloy is rotated at a well-defined frequency. This method was applied during the solidification of Nd-Fe-B alloys with the aim to suppress the volume fraction of undesired soft magnetic a-Fe phase. As a result, the volume fraction of properitectic phase with this method can be reduced up to 38 %. A detailed statistical analysis of secondary dendritic arm spacing (SDAS) measurements of a-Fe showed that the SDAS decreases as the rotational frequency increases and melt convection decreases. The reduction in the phase fraction and SDAS of properitectic phase is attributed to the reduced convective mass transfer under reduced melt motion. At high fluid velocity and low rotational frequency, the stronger interdendritic flow reduces the solute boundary layer and increases the transfer of solute through the interface. The smaller dendrite arms dissolve into the melt and thus the SDAS becomes higher than that of the samples solidified at higher rotational frequencies with reduced melt convection. Floating zone facility, which allows contactless heating without any contamination for highly reactive melts, was modified with a double coil system so that an additional electromagnetic force is introduced inside the melt. This induces either very intensive (two-phase stirrer in parallel connection coil system) or very reduced flow (series connection coil system) inside the melt The experimental results of series connection coil system showed that a reduced melt convection state is achieved near 5.1 mm coil distance where a-Fe volume fraction becomes minimum. On the contrary, the parallel coil system experiments showed that a-Fe volume fraction becomes maximum when the phase shift between the coils is close to 90°. The morphology of the a-Fe becomes globular due to spherical growth under strong convection. The study on the effect of strong stirring was extended to another alloy to get a generalized idea about the influence of melt convection on the microstructure development and resulting properties of peritectic alloys. Peritectic Ti45Al55 alloys were investigated by the two-phase stirrer using the coils connected in parallel to study the effect of enhanced melt convection. The increase in the properitectic phase fraction together with a strong change in the morphology from dendritic to spherical were observed in the stirred samples. The increase in the properitectic phase fraction occurs due to the enhanced effective mass transfer under strong melt convection. The change in morphology of the properitectic phase is attributed to spherical growth or fragmentation of dendrite arms under strong convection. The mechanical properties of Ti45Al55 alloys, which are solidified at different convection states, were studied. There was a significantly higher plastic deformability of stirred samples compared to unstirred samples. The coarse anisotropic orientation of the dendritic lamellar phase is detrimental for the plastic deformability, which is absent in the stirred samples due to the spherical and discrete morphology of the properitectic phase. This study indicates that tailored microstructure can be obtained either by decreasing (e.g. for Nd-Fe-B alloy) or increasing (e.g. for Ti-Al alloy) the convection state using effective techniques inside the melt to improve the magnetic and mechanical properties, respectively. Thus, controlling convection is a useful way to get favorable microstructure according to the process need.
25

Experimentelle Untersuchung des Einflusses von porös beschichteten Heizflächen auf vollständige Siedekennlinien von aufwärts-strömendem Wasser im einseitig beheizten Rechteckkanal

Goldschmidt, Robert. Unknown Date (has links) (PDF)
Techn. Universiẗat, Diss., 2004--Berlin.
26

Alternativa uppvärmningsmetoder : Inom gjutjärnsproduktion med avseende på ergonomi och flöde

Bäcklin, Josefine January 2017 (has links)
Syfte: Arbetets syfte är att undersöka befintlig produktionsutrustning och vad för alternativa metoder som kan appliceras utifrån en mer flödes inriktad och ergonomisk produktion. För att identifiera bristande faktorer har följande frågeställningar valts att besvaras: Vilka kriterier finns för att uppnå goda resultat för uppvärmningsprocess? Hur kan uppvärmningsmetoder skiljas åt och vilken metod skulle kunna appliceras på fallstudie-företaget? Hur kan ergonomiska principer bidra till en bättre arbetsmiljö? Metod: Studien har baserats på en fallstudie för att undersöka valda frågeställningar. Det möj-liggör en unik vinkel för ett specifikt fall, men med en kopplande litteraturstudie skapar ett bredare synfält vid analys av problemet. Tillvägagångssättet har innefattat processkartläggning, litteraturstudie och analys av data. Det har krävts observationer, intervjuer samt rådgivning från experter inom värmebehandlingscentrum för att uppfylla syftet och besvara frågeställningarna. Studiens resultat: Resultatet av studien har bevisats genom en processkartläggning över nuläget hos fallstudieföretaget. Kartläggning har skett för valda processer samt över ergonomin vid utförandet av arbetsuppgifterna. Brister har upptäckts genom produktionsutrustning som genererar defekta detaljer samt är inte utformad efter arbetarens fysiska begränsningar. Arbetsprocesserna hamnar inom minst gula nivåer, där rekommendationer är att ändra arbetsupplägget för att minska belastningen hos arbetaren. Det finns ett kritiskt arbetsmoment som indikerar en röd nivå, där arbetaren manuellt skjuter in och drar ut gods på över 100 kilogram i en dålig arbetsställning. Arbetsmetoderna har använts i över 30 år och även om antal anställda har reducerats har ingen förändring i upplägget skett. För att undvika att slita ut arbetaren krävs en im-plementation av förändring över arbetssättet, då momenten måste anpassas till att en arbetare utför dem.De tre frågeställningarna som har hjälp studiens framfart har besvarats och analyserats. Förslag till förbättringar har gjorts gällande alternativa metoder till uppvärmningsprocessen samt ergo-nomiska riktlinjer. En kombination av lösningsförslag presenteras i slutet av analysen där ett framtida upplägg gällande layout och kombination av produktionsutrustning i flödet ges som förslag. Slutsats: Arbetet har uppfyllt syftet genom processkartläggningen av befintlig produktionsut-rustning samt analys över alternativa metoder. Studien besvara de tre frågeställningarna som har möjliggjort en analys över produktionsutrustningen och ergonomi. Analysen över arbetet i gjutjärnsproduktionen har indikerat att investering i ny uppvärmningsprocess krävs. Förslag har angivits till ett framtida läge inom produktionen. Rekommendationer: För att fullfölja de förbättringar som har lyfts upp genom studien krävs vidare studier över att investera i en ny uppvärmningsprocess samt arbetsupplägget kring pro-cessen så som förändring av batchstorlekar, transportsätt och om racks är en optimal metod för att transportera godset. Om fallstudieföretaget ska fortsätta konkurrera bör en påbörjan till LEAN produktion genom ett första steg att analysera produktionssystemet.
27

Satellite observations of convection and their implications for parameterizations

Quaas, Johannes, Stier, Philip January 2016 (has links)
Parameterization development and evaluation ideally takes a two-step approach (Lohmann et al., 2007). Insight into new processes, and initial parameterization formulation should be guided by theory, process-level observations (laboratory experiments or field studies) or, if these are unavailable, by high-resolution modelling. However, once implemented into large-scale atmospheric models, a thorough testing and evaluation is required in order to assure that the parameterization works satisfactorily for all weather situations and at the scales the model is applied to. Satellite observations are probably the most valuable source of information for this purpose, since they offer a large range of parameters over comparatively long time series and with a very large, to global, coverage. However, satellites usually retrieve parameters in a rather indirect way, and some quantities (e.g., vertical wind velocities) are unavailable. It is thus essential for model evaluation 1. to assure comparability; and, 2. to develop and apply metrics that circumvent the limitations of satellite observations and help to learn about parameterizations. In terms of comparability, the implementation of so-called \"satellite simulators\" has emerged as the approach of choice, in which satellite retrievals are emulated, making use of model information about the subgrid-scale variability of clouds, and creating summary statistics (Bodas-Salcedo et al., 2011; Nam and Quaas, 2012; Nam et al., 2014). In terms of process-oriented metrics, a large range of approaches has been developed, e.g. investigating the life cycle of cirrus from convective detrainment (Gehlot and Quaas, 2012), or focusing on the details of microphysical processes (Suzuki et al., 2011). Besides such techniques focusing on individual parameterizations, the data assimilation technique might be exploited, by objectively adjusting convection parameters and learning about parameter choices and parameterizations in this way (Schirber et al., 2013).In this chapter, we will first introduce the available satellite data, consider their limitations and the approaches to account for these, and then discuss observations-based process-oriented metrics that have been developed so far.
28

Validierung des konvektiven Wärmeübergangs der Freeware Z88Aurora® mithilfe analytischer Beispiele und kommerzieller Software

Wittmann, Johannes, Hüter, Florian, Roppel, Matthias, Dinkel, Christian, Rieg, Frank 05 July 2019 (has links)
Die Finite Elemente Analyse hat sich in vielen industriellen Anwendungsgebieten zu einem elementaren Werkzeug für den Produktentwicklungsprozess entwickelt. Zu diesen Anwendungsbereichen zählen u. a. der Fahrzeugbau, die Medizintechnik und der Sondermaschinenbau. Neben Strömungssimulationen und der numerischen Berechnung von elastomechanischen Strukturen sind auch thermomechanische Analysen mithilfe der FEA durchführbar. Kleine und mittelständische Unternehmen können jedoch nicht immer auf einen wirtschaftlichen Einsatz von kommerziellen FEA-Tools zurückgreifen und sind folglich auf Freeware Programme wie Z88Aurora® angewiesen. Die häufig für den Entwickler interessierende stationäre Wärmeleitung und die aus dem Temperaturunterschied resultierende thermische Dehnung von Bauteilkomponenten gehören längst zum Tagesgeschäft. Für eine realitätsnahe Auslegung von beispielsweise Kühlkörpern oder Rippen muss zusätzlich die konvektive Wärmeübertragung berücksichtigt werden. Hierbei wird der Wärmetransport zwischen einer Bauteiloberfläche und dem Umgebungsmedium, wie z. B. Luft oder Kühlwasser, untersucht. Diese erweiterte Abbildung der Temperaturanalyse definiert als Randbedingung eine Wärmestromdichte auf einer Bauteiloberfläche, welche proportional zur Temperaturdifferenz beider Systemkomponenten ermittelt wird. Zudem gehen nichtlineare Einflüsse aus den Materialeigenschaften des Fluids und aus dem entstehenden Strömungsverhalten über den sog. Wärmeübergangskoeffizienten in die Simulation ein. Aufgrund dieser Komplexität kann über empirisch ermittelte Korrelationsgleichungen die Bestimmung des Wärmeübergangskoeffizienten erreicht werden. Diese Erweiterung des Thermomoduls wird in der neuen Version von Z88Aurora®V5 dem Anwender zur Produktentwicklung angeboten. Eine für den industriellen Einsatz essentielle Validierung der Berechnungsergebnisse wird über analytische Vergleichsrechnungen am Beispiel einer Kühlrippe nachgewiesen.
29

Analyse konvektiver Transportprozesse während der Magnetoelektrolyse

Mühlenhoff, Sascha 19 July 2012 (has links)
Untersuchung konvektiver Transportprozesse innerhalb einer auf der Lorentz-Kraft basierenden Strömung während der elektrolytischen Abscheidung.
30

Det invändiga tätskiktets historia / The history of the indoor environmentsealing

Liljekvist, Adam, Svensson, Danny January 2021 (has links)
Att bygga täta hus är något som alltid eftersträvats. Till en början var det för att öka den inre komforten med att förhindra drag i golv och väggar för att senare få förståelsen för hur otätheter kan var skadlig för våra konstruktioner i form av de termiska drivkrafterna i konvektion och diffusion genom byggnadsskalet. Då byggnadskraven och regelverken blivit hårdare har byggnadsbranschen och forskarsamfundet utvecklat nya lösningar för att konstruera tätare hus. Med syftet att öka och bredda den allmänna, grundläggande förståelsen och kunskapen inom området görs en historisk sammanställning om hur täthet har uppnåtts. Sammanställningen börjar vid 1800-talets slut i den moderna byggnadskonsten ursprung. I varje epok undersöks vilka typer av lösningar som kan förväntas att finnas i olika konstruktioner och hustyper, vilka forskningsrapporter och litteratur har legat till grund för den historiska utvecklingen samt vilka regelverk som varit styrande under respektive epok. Arbetet fokuserar enbart på den svenska utvecklingen inom täthet och berör enbart träkonstruktioner.En litteraturstudie är det som ligger till grund för rapporten där rapporter, tidskrifter och byggnadsanvisningar granskas. En dialog har förts med utredningsingenjör Stig Johansson.Syftet med dialogen har varit för att kunna ge vägledning samt för att belysa viktiga tidpunkter som bör undersökas.  Vidare undersöks när man började förstå att tätheten inte enbart påverkade komforten utan också påverkade effektiviteten hos ventilationssystemen och värmeisoleringen, det vill säga den totala energiförbrukningen. Arbetet visar att läckaget är som störst i skarvar mellan yttervägg och vindsbjälklag, yttervägg och golvbjälklag, i folie/pappskarvar samt vid genomföringar genom tätskiktet. Här har olika metoder använts för att uppnå så god täthet som möjligt. Allt ifrån klämning av skarvar till häftning och tejpning. Tätning reagerar olika på fukt och beständigheten hos de olika lösningarna kan vara olika efter några år. Studien visar att det var i början av 70-talet som forskarsamfundet förstod hur tätheten påverkade energihushållningen och ventilationen. Då togs metoder fram för tryckmätning av konstruktioner och energihushållningen kunde då beräknas.  Följande slutsatser kan dras ifrån studien: Det invändiga tätskiktet har förändrats väldigt mycket under det senaste århundradet, antagligen har förändringen varit styrd av ”trial and error”. Förändringen i materialval ifrån förhydningspapp till plastfolie beror främst på plastfoliens lätthanterlighet vid förvaring och montering. Det finns inte ett entydigt svar till när man insåg att det invändiga tätskiktet gjort mer nytta än att enbart täta mot drag. Men troligtvis var det kring 20-talet då begreppet diffusion diskuteras i rapporter. Monteringstekniken har förändrats mycket sedan plastfolien lanserades på marknaden. Antagligen är denna förändring driven dels av ”trial and error” tillsammans med de forskningar som upptäckten av felen har motiverat. / Building houses with proper indoor environmental sealing is something that always has been strived after. At the beginning the purpose was to increase indoor comfort by stopping gusts of wind in floors and ceilings. Later, understanding was gained how leaks can be damaging for our constructions in the shape of thermal forces in convection and diffusion through the environment sealing. With the purpose of increasing and broadening the general, basic understanding and knowledge in the field a compilation from a historical perspective of how isolation is achieved. This essay is focused solely on the Swedish development in isolation of wooden structures. The foundation of this essay is based on a literature study where rapports, periodicals and building instructions are examined.  Another area of study that is examined here is when a proper understanding of the benefits of isolation was reached in relation to its impact on the efficiency of ventilation systems and heat isolation, which impacts the total energy consumption.  The following conclusion can be made from the study:  The indoor environment sealing has changed a lot in the latest hundred years and the change was probably made by ”trial and error”. The change in material is probably due to the easiness when using the plastic folie.      There is not only one answer to when the realization was made that the indoor sealing had more of a purpose than protection against gusts. But it was probably in the 1920´s.  The installation technique has change since the introduction of the plastic folie. The change was probably made by ”trial and error” or in a combination with the scientific discoveries that was made.

Page generated in 0.0734 seconds