Spelling suggestions: "subject:"La electrocatalysis"" "subject:"La electrodialysis""
11 |
Electrochemical studies of carbon-based materialsWisetsuwannaphum, Sirikarn January 2014 (has links)
Graphene, as a recently discovered carbon allotrope, possesses with it many outstanding properties ranging from high electrical conductivity to great mechanical strength. Single layer graphene can be prepared by mechanical cleavage of graphite or by a more sophisticated method, CVD. However, the scale-up process for these preparation techniques is still unconvincing. Solution-processed graphene from exfoliation of graphite oxide on the other hand provides an alternative prospect resulting in the formation of graphene nanoplatelets (GNPs), which can be readily manipulated to tailor-suit various application demands. The main aim of the thesis is to explore the possibility and availability of this versatile method to produce graphene nanoplatelet and its composites with good all-round performance in energy and bioanalytical applications. A range of physical and chemical characterisation techniques were utilised including SEM, TEM, AFM, XPS, XRD, DLS, FTIR, Raman and UV-Vis spectroscopy in order to investigate the structural and chemical information of the graphene-based materials prepared. Functionalisation of graphene oxide with polyelectrolyte polymer could facilitate deposition of platinum nanoparticles in the formation of Pt-GNPs composites. The resultant composite was employed for bioanalytical application in the detection of an important neurotransmitter, glutamate, based on glutamate oxidase enzyme. The performance of Pt-GNPs based glutamate sensor exhibited enhanced sensitivity and prolonged stability compared to the sensors based on Pt decorated diamond or glassy carbon electrodes. The significant interfering effect from concomitant electrochemically active biological compounds associated with Pt-GNPs electrode however could be alleviated via opting for Prussian blue deposited GNPs electrode instead. The oppositely charged Pt-GNPs due to different functionalising polymers were also subject to self-assembly, which was enabled by the electrostatic interaction of the opposite charges of Pt-GNPs. The self-assembled film showed enhanced mechanical stability than the conventional drop-casted film and provided reasonably good activity towards oxidation of hydrogen peroxide. Three-component composite of graphene, nanodiamond and polyaniline was prepared via in-situ polymerisation for usage as an electrode material in electrochemical capacitors ("supercapacitors"). The addition of graphene was shown to significantly enhance specific capacitance while nanodiamond could improve the stability of the electrode by strengthening the polymer core. Another approach to produce a supercapacitor was via electrodeposition of nickel and cobalt hydroxides on graphene oxide film corporated with bicarbonate salt. The film was then subject to thermal reduction of GO and expansion of graphene layers within the film was observed. This leavening process enhanced the surface area of graphene film and thus the higher specific capacitance was obtained. The decoration of nickel and cobalt hydroxides onto the film also boosted the specific capacitance further however the poor cycling stability of the heated film still remained an issue. Graphene nanoplatelets were also used as a support for electrodeposition of Pt nanoparticles for methanol oxidation in acidic media. The preferential phase of the Pt deposited and large surface area of graphene in comparison to other carbon supports studied led to good catalytic activity being observed.
|
12 |
Desenvolvimento e aplicações de eletrodos de ouro confeccionados a partir de discos compactos graváveis (CD-Rs) / Development and applications of gold electrodes confectioned from recordable compact disc (CD-RS)Richter, Eduardo Mathias 22 January 2001 (has links)
O presente trabalho descreve uma forma inédita e simples de construção de eletrodos de ouro (CDtrodos) a partir de discos compactos graváveis (CD-Rs). Os CD-Rs possuem em sua constituição uma película de ouro com uma espessura entre 50 e 100 nm e com área aproximada de 100 cm2. Esta superfície de ouro pode ser facilmente utilizada para construção de eletrodos convencionais usados em células estacionárias ou em células em fluxo. Além disso, a espessura nanométrica do filme de ouro também pode ser utilizada para construção de microeletrodos de banda com áreas inferiores a 10-6 cm2. Devido ao fato do CD-R ser produzido em escala comercial, o custo do mesmo é muito baixo, tornando possível sua utilização na forma de eletrodos descartáveis. Para comprovar a viabilidade da utilização destes filmes na confecção de eletrodos, seu desempenho foi comparado com o de eletrodo de ouro comercial, sendo observado um comportamento análogo. Diferentes maneiras de utilização do disco compacto gravável foram testadas, tanto em amostras sintéticas, como também, em amostras reais. Utilizando o método de redissolução potenciométrica à corrente constante (CCPSA), foram analisadas amostras de mercúrio em água potável e em água do mar, adaptando o CD-R a uma célula de injeção em fluxo. Nestes estudos, o limite de detecção de mercúrio situou-se em 250 ng L-1, utilizando-se tempo de deposição de 300 segundos. Estudos preliminares em células estacionárias levaram a limites de detecção inferiores. Em célula estacionária, foram realizadas análises de cobre em aguardente e em água potável. Em alguns casos, os resultados obtidos com as amostras reais foram comparados com outra técnica (E.A.A.), onde os resultados obtidos foram muito próximos a àqueles obtidos com os eletrodos de ouro. Análises em água de abastecimento, mostraram que em células estacionárias o limite de detecção para cobre situa-se em 30 ng L-1, para tempos de deposição de 600 segundos. / This work describes an original and novel form of construction of gold electrodes (CDtrodes) from recordable CDs (CD-Rs). The CD-Rs contain in its constitution a fine gold layer with a thickness from 50 to 100 nm and an approx. 100 cm2 of area. This surface can be easily used for construction of conventional electrodes for stationary or flow electrochemical cells. Moreover, the nanometer thickness of the gold film can be employed for the construction of microelectrodes with areas smaller than 10-6 cm2. Due to the fact that CD-Rs are produced on commercial scale, the cost of each unit is very low, a feature that enables the use of these electrodes in disposable form. To prove the suitability of these films to make gold electrodes, their performance was compared with the response of a commercial electrode, and a similar behavior was observed. Different applications of recordable compact disk were tested either with synthetic or real samples. Using the Constant-Current Potentiometric Stripping Analysis (CCPSA) method, mercury was analyzed in seawater and drinking water samples, fitting the CD-R to flow injection analysis cell. In these studies, the detection limit for mercury was found to be 250 ng L-1, with a deposition time of 300 seconds. Preliminary studies involving stationary cells allowed lower detection limits for mercury to be attained. With a stationary cell, the analyses of copper in sugar cane spirits and drinking water were carried out. In some instances, comparisons were made between this and another analytical technique (namely A.A.S.) where the results were very close with the ones obtained with the gold electrodes. Analysis of drinking water showed that for stationary cells the detection limit for copper is 30 ng L-1, with a deposition time of 600 s.
|
13 |
Determinação eletroanalítica e cromatográfica de Metilparabeno. Uma comparação estatística / Electroanalytical and chromatographic determination of Methylparaben. A statistical comparisonMendonça, Camila Domingues 31 July 2015 (has links)
A cromatografia a líquido de alta eficiência e a voltametria de onda quadrada foram estudadas e comparadas estatisticamente para a detecção do contaminante emergente metilparabeno (MePa). Os parabenos vêm sendo amplamente utilizados como conservantes em cosméticos, alimentos e remédios. É crescente o número de estudos que visam à detecção dos parabenos em virtude dos males causados à saúde humana, devido às suas características de serem carcinogênicos e interferentes endócrinos. Para determinação cromatográfica, foi desenvolvido um método analítico que utilizou filtração à vácuo seguida de análise cromatográfica acoplada a um detector UV. O eletrodo de diamante dopado com boro (BDD) foi utilizado para determinação eletroanalítica de MePa pela técnica voltamétrica. Para a análise cromatográfica, foi observada boa linearidade (0,999) na faixa de 0,5 a 30 mgL-1, com limite de detecção e quantificação de 0,49 mgL-1 e 0,73 mgL-1, respectivamente, para amostra de água natural superficial e para a amostra de cosmético 1,26 mgL-1 e 1,88 mgL-1, respectivamente. A dependência da corrente pelo pH e os parâmetros eletroquímicos (frequência, amplitude e step) foram estudados para obtenção de condições experimentais ótimas na determinação de MePa. Foi observado que o eletrólito suporte ideal é o tampão PBS 0,1 molL-1 (pH 7,5). Linearidade adequada (0,998), na mesma faixa de trabalho, com limite de detecção e quantificação de 0,43 mgL-1 e 1,44 mgL-1, respectivamente, foram encontrados para a técnica voltamétrica. Os métodos utilizados em ambas as técnicas foram validados em uma amostra de água natural superficial, coletada em região pouco impactada, e em uma amostra de cosmético. Utilizando o método cromatográfico, foram obtidos intervalos de recuperação entre 95,6% e 101,6% com RSD inferior a 4,8% (n = 3) e entre 78,0% e 99,8% com RSD inferior a 2,2% (n = 3) para amostras de água natural superficial e de cosmético, respectivamente. Na determinação eletroanalítica, soluções fortificadas daquelas amostras mostraram intervalo de recuperação entre 92,6% e 106,4%, com um desvio-padrão relativo (RSD) inferior a 9,76% (n = 3), para amostra de água superficial natural, e entre 90,0% e 112,6% com RSD inferior a 7,4% (n = 3), para amostra de cosmético. Os resultados das detecções cromatográfica e eletroanalítica foram comparados e analisados estatisticamente segundo o método de Miller e Miller. Através do teste t de Student pareado, demonstrou-se que a metodologia eletroanalítica é capaz de determinar MePa com boa precisão tal como a técnica padrão de detecção, a cromatografia, na faixa de trabalho de 1,0 a 30 mgL-1. / The high performance liquid chromatography and square wave voltammetry have been studied and compared statistically to detect the emerging contaminant methylparaben (MePa). Parabens have been widely used as preservatives in cosmetics, food and drugs. It is increasing the number of studies that aimed the detection of parabens because of its possible hazardous effect in the human health, as probably being carcinogenics and endocrine disruptors. For chromatographic determination, an analytical method that used vacuum filtration followed by chromatographic analysis coupled to a UV detector was developed. The boron doped diamond electrode (BDD) was used to electroanalytical determination to MePa by voltammetric technique. The chromatographic analysis showed good linearity (0.999) in the range from 0.5 to 30 mgL-1, with detection and quantification limit of 0.49 mgL-1 and 0.73 mgL-1, respectively, for natural surface water sample and to the cosmetic sample 1.26 mgL-1 and 1.88 mgL-1, respectively. The dependence of the current to pH and electrochemical parameters (frequency, amplitude and step) were studied to obtain the optimal experimental conditions in determining MePa. It has been observed that the ideal supporting electrolyte is PBS 0.1 molL-1 (pH 7.5). Adequate linearity (0.998), in the same working range, with detection and quantification limit of 0.43 mgL-1 and 1.44 mgL-1, respectively, were found for the voltammetric technique. The methods used in both techniques were validated in a sample of natural surface water, collected in little impacted region, and a cosmetic sample. Using the chromatographic method were obtained recovery intervals between 95.6% and 101.6% with RSD less than 4.8% (n = 3) and between 78.0% and 99.8% with RSD less than 2.2% (n = 3) for samples of natural surface water and cosmetic, respectively. In electroanalytic determination, fortified solutions of those samples showed a recovery range between 92.6% and 106.4% with a relative standard deviation (RSD) less than 9.76% (n = 3) for natural surface water sample and between 90.0% and 112.6% with RSD less than 7.4% (n = 3), for cosmetic sample. The results of chromatographic and electroanalytical detections were compared and statistically analyzed by the Miller and Miller\'s method. Using the Student\'s paired t-test, it was demonstrated that electroanalytical methodology is able to determine MePa with good accuracy as standard detection technique, chromatography, on working range of 1.0 to 30 mgL-1.
|
14 |
Análise de moléculas secretadas por populações celulares utilizando técnicas eletroanalíticas / Cell secreted molecules analysis by electroanalytical techniquesOliveira, André Guimarães de 21 December 2012 (has links)
O ácido cis-11-metil-2-dodecenóico (DSF), substância utilizada como autoindutor nos sistemas de Quorum Sensing da bactéria Xanthomonas axonopodis pv. citri, foi utilizado como um modelo de estudos para a análise de moléculas secretadas por populações celulares utilizando técnicas eletroanalíticas. Cultivos celulares provenientes de três linhagens diferentes da bactéria Xanthomonas axonopodis pv. citri foram utilizados para os estudos. Uma linhagem selvagem (WT), que produzia DSF em quantidades naturalmente observadas, e duas linhagens geneticamente modificadas. Em uma linhagem (ΔC) a modificação genética resultava em elevada produção de DSF, para a segunda (ΔF) o resultado era a anulação da produção do autoindutor. As principais técnicas analíticas utilizadas foram: voltametria cíclica, eletroforese capilar e cromatografia líquida (com detecção UV-Vis e acoplada a espectrometria de massas), sendo a última para efeitos de comparação. Procedimentos de extração líquido-líquido com solventes orgânicos foram realizados como etapas de pré-tratamento de amostras, visando diminuir a quantidade de interferentes e realizar uma pré-concentração do analito. Três metodologias principais foram adotadas. Uma primeira voltada para a diferenciação dos cultivos celulares, analisando-se ou os sobrenadantes provenientes dos cultivos ou os extratos resultantes dos pré-tratamentos desses sobrenadantes, tendo como principal foco a identificação de um sinal diferencial entre os cultivos que correspondesse às quantidades de DSF, ou seja, inexistente para a linhagem ΔF, de alta intensidade para linhagem ΔC e de intensidade intermediária para a linhagem WT. A segunda metodologia foi baseada no uso de uma molécula modelo para realizar experimentos e obter dados como parâmetros físico-químicos, o ácido láurico (ácido dodecanóico) foi escolhido por sua semelhança estrutural e facilidade de obtenção, curvas de calibração e experimentos de separação de moléculas com estrutura semelhante foram realizados com a técnica de eletroforese capilar. Uma terceira metodologia foi desenvolvida utilizando o padrão do ácido cis-11-metil-2-dodecenóico (DSF), curvas de calibração foram obtidas com o padrão isolado apresentando ótimas linearidades, tanto com a técnica de eletroforese capilar quanto com cromatografia líquida com detecção UV-Vis, experimentos de adição de padrão às amostras também foram executados. Os experimentos realizados com as amostras não apresentaram os resultados esperados, os problemas foram associados principalmente à quantidade de interferentes na amostra e a baixa concentração do analito nos cultivos, sendo que os métodos de extração realizados não foram suficientes para solucioná-los. O insucesso da técnica de voltametria cíclica foi associado ao envenenamento do eletrodo, devido à alta quantidade de compostos orgânicos presentes na amostra, e dúvidas relacionadas à eletroatividade do DSF. As dificuldades encontradas com a técnica de eletroforese capilar foram associadas à alta força iônica da amostra, presença de interferentes e baixa concentração do analito nos cultivos. Mesmo os experimentos realizados com cromatografia líquida acoplada a detecção com espectrometria de massas não atenderam às expectativas, dificultando a elucidação dos problemas encontrados até então e impossibilitando o desenvolvimento de uma metodologia que atendesse aos objetivos propostos. / Cis-11-methyl-2-dodecenoic acid, also known as DSF (autoinducer of the Quorum Sensing system used by the bacteria Xanthomonas axonopodis pv. citri) was explored as a study model for the cell secreted molecules analysis by electroanalytical techniques. Cell cultures from three different cell lines of the bacteria Xanthomonas axonopodis pv. citri were used for this study. A wild type (WT), which produced DSF in naturally observed quantities and two genetically modified ones. One of the lines (ΔC) had a genetic modification that resulted in an elevated production of DSF, and the other (ΔF) had a modification that stopped DSF production. Main analytical techniques used were: cyclic voltammetry, capillary electrophoresis and liquid chromatography (with UV-Vis detection and coupled with mass spectrometry), this last one was used with comparison purposes. Liquid-liquid extractions with organic solvents were realized as sample pre-treatment steps aiming the reduction of interfering species and analyte pre-concentration. Three main methodologies were adopted. One based in the differentiation of cell cultures analyzing or the cell culture supernatants or the resulting extracts from the pre-treatment steps. The main focus was the identification of a differential signal between the cultures that corresponded to the DSF quantities, in other words, null for the ΔF line, high intensity for the ΔC line and a an intermediary intensity for the WT line. The second methodology was based in experiments with a model molecule to obtain some data such as physical-chemistry parameters. Lauric acid (dodecanoic acid) was chosen for its structural similarity and easily acquisition. Calibration curves and similar structure molecules separation experiments were realized using capillary electrophoresis. Third and last methodology was developed using standard cis-11-methyl-2-dodecenoic acid (DSF). Calibration curves were obtained with the isolated standard showing great linearities using both capillary electrophoresis and liquid chromatography with UV-Vis detection. Experiments of standard addiction to the samples were also realized. Experiments using the samples did not show the expected results. Problems found were mainly associated with high amount of interfering species and low analyte concentration at the cultures, extraction methods used were not enough to solve this. The failures with the cyclic voltammetric techniques were associated to electrode poisoning, due to the high amount of organic compounds present at the sample, and DSF lack of electroactivity. Difficulties found with capillary electrophoresis were associated with the samples high ionic strength, presence of interfering species and low analyte concentration. Even liquid chromatography coupled with mass spectrometry experiments didn\'t attended the expectations. Making it difficult to elucidate the problems and not allowing the development of a methodology that could achieve the proposed objectives.
|
15 |
Determinação eletroanalítica e cromatográfica de Metilparabeno. Uma comparação estatística / Electroanalytical and chromatographic determination of Methylparaben. A statistical comparisonCamila Domingues Mendonça 31 July 2015 (has links)
A cromatografia a líquido de alta eficiência e a voltametria de onda quadrada foram estudadas e comparadas estatisticamente para a detecção do contaminante emergente metilparabeno (MePa). Os parabenos vêm sendo amplamente utilizados como conservantes em cosméticos, alimentos e remédios. É crescente o número de estudos que visam à detecção dos parabenos em virtude dos males causados à saúde humana, devido às suas características de serem carcinogênicos e interferentes endócrinos. Para determinação cromatográfica, foi desenvolvido um método analítico que utilizou filtração à vácuo seguida de análise cromatográfica acoplada a um detector UV. O eletrodo de diamante dopado com boro (BDD) foi utilizado para determinação eletroanalítica de MePa pela técnica voltamétrica. Para a análise cromatográfica, foi observada boa linearidade (0,999) na faixa de 0,5 a 30 mgL-1, com limite de detecção e quantificação de 0,49 mgL-1 e 0,73 mgL-1, respectivamente, para amostra de água natural superficial e para a amostra de cosmético 1,26 mgL-1 e 1,88 mgL-1, respectivamente. A dependência da corrente pelo pH e os parâmetros eletroquímicos (frequência, amplitude e step) foram estudados para obtenção de condições experimentais ótimas na determinação de MePa. Foi observado que o eletrólito suporte ideal é o tampão PBS 0,1 molL-1 (pH 7,5). Linearidade adequada (0,998), na mesma faixa de trabalho, com limite de detecção e quantificação de 0,43 mgL-1 e 1,44 mgL-1, respectivamente, foram encontrados para a técnica voltamétrica. Os métodos utilizados em ambas as técnicas foram validados em uma amostra de água natural superficial, coletada em região pouco impactada, e em uma amostra de cosmético. Utilizando o método cromatográfico, foram obtidos intervalos de recuperação entre 95,6% e 101,6% com RSD inferior a 4,8% (n = 3) e entre 78,0% e 99,8% com RSD inferior a 2,2% (n = 3) para amostras de água natural superficial e de cosmético, respectivamente. Na determinação eletroanalítica, soluções fortificadas daquelas amostras mostraram intervalo de recuperação entre 92,6% e 106,4%, com um desvio-padrão relativo (RSD) inferior a 9,76% (n = 3), para amostra de água superficial natural, e entre 90,0% e 112,6% com RSD inferior a 7,4% (n = 3), para amostra de cosmético. Os resultados das detecções cromatográfica e eletroanalítica foram comparados e analisados estatisticamente segundo o método de Miller e Miller. Através do teste t de Student pareado, demonstrou-se que a metodologia eletroanalítica é capaz de determinar MePa com boa precisão tal como a técnica padrão de detecção, a cromatografia, na faixa de trabalho de 1,0 a 30 mgL-1. / The high performance liquid chromatography and square wave voltammetry have been studied and compared statistically to detect the emerging contaminant methylparaben (MePa). Parabens have been widely used as preservatives in cosmetics, food and drugs. It is increasing the number of studies that aimed the detection of parabens because of its possible hazardous effect in the human health, as probably being carcinogenics and endocrine disruptors. For chromatographic determination, an analytical method that used vacuum filtration followed by chromatographic analysis coupled to a UV detector was developed. The boron doped diamond electrode (BDD) was used to electroanalytical determination to MePa by voltammetric technique. The chromatographic analysis showed good linearity (0.999) in the range from 0.5 to 30 mgL-1, with detection and quantification limit of 0.49 mgL-1 and 0.73 mgL-1, respectively, for natural surface water sample and to the cosmetic sample 1.26 mgL-1 and 1.88 mgL-1, respectively. The dependence of the current to pH and electrochemical parameters (frequency, amplitude and step) were studied to obtain the optimal experimental conditions in determining MePa. It has been observed that the ideal supporting electrolyte is PBS 0.1 molL-1 (pH 7.5). Adequate linearity (0.998), in the same working range, with detection and quantification limit of 0.43 mgL-1 and 1.44 mgL-1, respectively, were found for the voltammetric technique. The methods used in both techniques were validated in a sample of natural surface water, collected in little impacted region, and a cosmetic sample. Using the chromatographic method were obtained recovery intervals between 95.6% and 101.6% with RSD less than 4.8% (n = 3) and between 78.0% and 99.8% with RSD less than 2.2% (n = 3) for samples of natural surface water and cosmetic, respectively. In electroanalytic determination, fortified solutions of those samples showed a recovery range between 92.6% and 106.4% with a relative standard deviation (RSD) less than 9.76% (n = 3) for natural surface water sample and between 90.0% and 112.6% with RSD less than 7.4% (n = 3), for cosmetic sample. The results of chromatographic and electroanalytical detections were compared and statistically analyzed by the Miller and Miller\'s method. Using the Student\'s paired t-test, it was demonstrated that electroanalytical methodology is able to determine MePa with good accuracy as standard detection technique, chromatography, on working range of 1.0 to 30 mgL-1.
|
16 |
Nanostructured Metal Electrodes for Wool Processing and ElectroanalysisCruickshank, Amy Clare January 2007 (has links)
The research presented in this thesis firstly concerns the use of electrochemical techniques to develop approaches to wool processing which have a lower impact on the environment than conventional chemical methods. Wool is a sulfur rich substrate and current methods used in wool processing often rely on sulfur-based reducing agents such as metabisulfite. However, due to increasing concern over the environmental impacts of metabisulfite, alternative methods are of interest. Electrochemical techniques have been applied to the process of wool setting in the presence of thiol setting agents. Wool disulfide bonds are reduced during this process and the thiol setting agent is converted to the disulfide. Efficient conversion of the disulfide back to the thiol setting agent would allow catalytic amounts of thiols to be used in wool setting. The electroreduction of cystine and 2-hydroxyethyl disulfide has been examined at a range of metal and carbon electrodes to find efficient methods of generating the corresponding thiols, cysteine and 2-mercaptoethanol respectively. Gold and silver were identified as the most efficient electrode materials. In industrial wool processing, the use of large-scale metal electrodes is expensive and therefore, high surface area gold and silver nanoparticle electrodes were fabricated by electrochemically depositing the metals onto low-cost carbon substrates. The most efficient electrochemical system for generating the thiol setting agent involved the electroreduction of cystine at the gold nanoparticle electrode and this system was used to successfully demonstrate that wool setting can be achieved using relatively low concentrations of cysteine. Further research was carried out to investigate methods for the controlled preparation of metal nanoparticle electrodes and their utility for detecting hydrogen peroxide was examined. A simple and versatile approach for the preparation of tethered gold nanoparticle assemblies was developed by exploiting electrostatic interactions between citrate-capped gold nanoparticles and amine tether layers attached to carbon surfaces. The nanoparticle assemblies were optimised for the detection of hydrogen peroxide by selecting the size and density of electrostatically assembled nanoparticles. The number of amine functionalities on the surface and the assembly conditions controlled the nanoparticle density. Nanostructured palladium electrodes fabricated using vapour deposition methods to immobilise palladium nanoparticles directly onto carbon substrates were also examined for the electroanalysis of hydrogen peroxide.
|
17 |
Électrodes macroporeuses d’oxyde d’indium dopé à l’étain préparées par électrofilage pour l’analyse spectroélectrochimique / Macroporous electrospun indium tin oxide electrodes for spectroelectrochemical analysisMierzwa, Maciej 07 December 2017 (has links)
Il y a un intérêt croissant concernant la découverte de nouvelles méthodes commercialement viables pour réaliser des analyses spectro-électrochimiques — combinant des techniques électrochimiques et spectrales. Pour ce faire, nous avons préparé un matériau d'électrode transparent et conducteur, l’oxyde d’indium dopé à l’étain. Nous avons utilisé la technique d’électrofilage conduisant à la formation de fibres très fines avec une surface spécifique élevée. Ces électrodes ont ensuite été recouvertes d'une couche supplémentaire de silice poreuse et fonctionnalisée pour maximiser la surface spécifique et introduire des propriétés de détection supplémentaires. Le dispositif a été utilisé dans la détection du bleu de méthylène qui est un colorant industriel mais également un polluant environnemental. il a été mis en évidence qu’avec l'utilisation d'une telle électrode, il était possible de détecter des concentrations inférieures aux niveaux environnementaux nocifs. Enfin, les électrodes fonctionnalisées ont également été utilisées avec succès pour générer une luminescence plus intense et plus stable, ce qui ouvre de nouvelles perspectives pour la conception de capteurs spectroélectrochimiques / There is a growing interest in finding new and commercially viable methods of performing a spectroelectrochemical analysis which combines electrochemical and spectral techniques. For this purpose, an electrode material that is transparent and conductive needs to be prepared. In this work, such electrode was prepared by electrospinning which is a technique capable of forming very thin fibers with high surface area. Those electrodes were also covered with additional layer of porous and functionalized silica to maximize the surface area and introduced additional sensing properties. This material was used in the detection of methylene blue which is an industrial dye and an environmental pollutant. It was found that using such electrode it was possible to detect concentrations that are smaller than the harmful environmental levels. Finally, the layers were also used with success to generate luminescence which is opening new prospects for the design of spectroelectrochemical sensors
|
18 |
Sensores e Biossensores EletroquÃmicos: Ferramentas VersÃteis para a DeterminaÃÃo de Contaminantes Ambientais. / Electrochemical sensors and biosensors: versatile tools for the environmental contaminants determinationFrancisco Wirley Paulino Ribeiro 30 July 2014 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / No presente trabalho apresentou-se o emprego de sensores e de biossensores eletroquÃmicos para a determinaÃÃo dos pesticidas endossulfam (EDS), tiabendazol (TBZ) e cloridrato de formetanato (FMT) em amostras de cana-de-aÃÃcar, tomate, manga, uva e Ãguas naturais. AlÃm disso, informaÃÃes acerca do mecanismo redox dos pesticidas EDS, TBZ e FMT tambÃm foram apresentadas. Os sensores consistiram em eletrodos de gota pendente de mercÃrio (HMDE, do inglÃs Hanging Mercury Drop Electrode), de diamante dopado com boro (EDDB) e de carbono vÃtreo modificado com nanotubos de carbono de paredes mÃltiplas funcionalizados e ftalocianina de cobalto (CV/NTCPMF-FcCo-Naf.0,5%). Para os biossensores, a enzima Lacase (Lac) foi imobilizada pelo mÃtodo de ligaÃÃes cruzadas sobre ouro previamente modificado com nanopartÃculas de ouro (Au/NpAu/Lac-Glu.2%) e sobre eletrodo modificado com NTCPMF-FcCo (CV/NTCPMF-FcCo-Naf.0,5%/Lac-Glu.2%). A reduÃÃo do EDS foi regida por processo quase-reversÃvel. TBZ sofreu oxidaÃÃo irreversÃvel sobre EDDB e CV/NTCPMF-FcCo-Naf.0,5%. FMT sobre EDDB apresentou oxidaÃÃo irreversÃvel do tipo quÃmico-eletroquÃmico. No entanto, mecanismo eletroquÃmico-quÃmico-eletroquÃmico foi observado para FMT sobre CV/NTCPMF-FcCo-Naf.0,5%, totalizando quatro processos de oxidaÃÃo (um irreversÃvel, dois quase-reversÃveis e um reversÃvel). Os valores dos limites de detecÃÃo (LD) e de quantificaÃÃo (LQ) calculados foram: LD = 0,121 mg kgâ1 e LQ = 0,406 mg kgâ1 (EDS sobre HMDE), LD = 0,074 mg kgâ1 e LQ = 0,247 mg kgâ1 (EDS sobre CV/NTCPMF-FcCo-Naf.0,5%/Lac-Glu.2%), LD = 0,052 mg kgâ1 e LQ = 0,177 mg kgâ1 (TBZ sobre EDDB), LD = 0,019 mg kgâ1 e LQ = 0,064 mg kgâ1 (TBZ sobre CV/NTCPMF-FcCo-Naf.0,5%), LD = 0,094 mg kgâ1 e LQ = 0,311 mg kgâ1 (TBZ sobre CV/NTCPMF-FcCo-Naf.0,5%/Lac-Glu.2%), LD = 0,094 mg kgâ1 e LQ = 0,314 mg kgâ1 (FMT sobre EDDB), LD = 0,025 mg kgâ1 e LQ = 0,083 mg kgâ1 (FMT sobre CV/NTCPMF-FcCo-Naf.0,5%), LD = 0,088 mg kgâ1 e LQ = 0,299 mg kgâ1 (FMT sobre Au/NpAu/Lac-Glu.2%). Estes valores estÃo de acordo com os limites mÃximos de resÃduos estabelecidos pela AgÃncia Nacional de VigilÃncia SanitÃria para os pesticidas EDS, TBZ e FMT (0,01 a 10,0 mg kgâ1).Os valores dos percentuais de recuperaÃÃo calculados variaram de 70,89 a 117,32%, com desvio padrÃo relativo entre 0,18 e 7,58%. Portanto, os resultados obtidos comprovaram que as metodologias eletroanalÃticas desenvolvidas podem ser consideradas alternativas promissoras para a determinaÃÃo de pesticidas em matrizes alimentares e ambientais. / The present work emphasized the use of electrochemical sensors and biosensors for the determination of endosulfan (EDS, organochlorine), thiabendazole (TBZ, benzimidazole) and formetanate hydrochloride (FMT, carbamate) pesticides in sugar cane, tomato, mango, grape and natural waters samples. Furthermore, insights of redox mechanistic of EDS, TBZ and FMT pesticide were also presented. The hanging mercury drop electrode (HMDE), boron-doped diamond electrode (BDDE) and cobalt phthalocyanine with functionalyzed multi-walled carbon nanotube modified glassy carbon electrode (Naf.0.5%-PcCo-fMWCNT/GCE) sensors were used. For biossensors, Laccase enzyme (Lac) was imobilized via cross-linking onto a gold electrode previously modified with gold nanoparticles (Glu.2%-Lac-AuNp/Au) and onto a PcCo-fMWCNT modified electrode (Glu.2%-Lac/Naf.0.5%-PcCo-fMWCNT/GCE). EDS was reduced by quase-reversible process. TBC was oxidized by an irreversible process on a BDDE and Naf.0.5%-PcCo-fMWCNT/GCE. The electrochemical response of FMT on a BDDE showed the irreversible oxidation mechanism of the type chemical-electrochemical. However, the electrochemical-chemical-electrochemical mechanism was observed for FMT at Naf.0.5%-PcCo-fMWCNT/GCE with four oxidation process (one irreversible, two quase-reversible and one reversible processes). The detection limits (DL) and quantification limits (QL) calculated values were: DL = 0.121 mg kgâ1 and QL = 0.406 mg kgâ1 (EDS at HMDE), DL= 0.074 mg kgâ1 and QL = 0.247 mg kgâ1 (EDS at Glu.2%-Lac/Naf.0.5%-PcCo-fMWCNT/GCE), DL = 0.052 mg kgâ1 and QL = 0.177 mg kgâ1 (TBZ at BDDE), DL = 0.019 mg kgâ1 and QL = 0.064 mg kgâ1 (TBZ at Naf.0.5%-PcCo-fMWCNT/GCE), DL = 0.094 mg kgâ1 and QL = 0.311 mg kgâ1 (TBZ at Glu.2%-Lac/Naf.0.5%-PcCo-fMWCNT/GCE), DL = 0.094 mg kgâ1 and QL = 0.314 mg kgâ1 (FMT at BDDE), DL = 0.025 mg kgâ1 and QL = 0.083 mg kgâ1 (FMT at Naf.0.5%-PcCo-fMWCNT/GCE), DL = 0.088 mg kgâ1 and QL = 0.299 mg kgâ1 (FMT at Glu.2%-Lac-AuNp/Au). These values are according to maximum residue limits established by National Health Surveillance Agency for EDS, TBZ and FMT pesticides (0.01 a 10.0 mg kgâ1). The calculated recovery percentages varied from 70.89 to 117.32% with relative standard desviation from 0.18 to 7.58%. Thus, electrochemical sensors and biosensors can be considered as an alternative tool for pesticides determination in foods and environmental matrices.
|
19 |
Análise de moléculas secretadas por populações celulares utilizando técnicas eletroanalíticas / Cell secreted molecules analysis by electroanalytical techniquesAndré Guimarães de Oliveira 21 December 2012 (has links)
O ácido cis-11-metil-2-dodecenóico (DSF), substância utilizada como autoindutor nos sistemas de Quorum Sensing da bactéria Xanthomonas axonopodis pv. citri, foi utilizado como um modelo de estudos para a análise de moléculas secretadas por populações celulares utilizando técnicas eletroanalíticas. Cultivos celulares provenientes de três linhagens diferentes da bactéria Xanthomonas axonopodis pv. citri foram utilizados para os estudos. Uma linhagem selvagem (WT), que produzia DSF em quantidades naturalmente observadas, e duas linhagens geneticamente modificadas. Em uma linhagem (ΔC) a modificação genética resultava em elevada produção de DSF, para a segunda (ΔF) o resultado era a anulação da produção do autoindutor. As principais técnicas analíticas utilizadas foram: voltametria cíclica, eletroforese capilar e cromatografia líquida (com detecção UV-Vis e acoplada a espectrometria de massas), sendo a última para efeitos de comparação. Procedimentos de extração líquido-líquido com solventes orgânicos foram realizados como etapas de pré-tratamento de amostras, visando diminuir a quantidade de interferentes e realizar uma pré-concentração do analito. Três metodologias principais foram adotadas. Uma primeira voltada para a diferenciação dos cultivos celulares, analisando-se ou os sobrenadantes provenientes dos cultivos ou os extratos resultantes dos pré-tratamentos desses sobrenadantes, tendo como principal foco a identificação de um sinal diferencial entre os cultivos que correspondesse às quantidades de DSF, ou seja, inexistente para a linhagem ΔF, de alta intensidade para linhagem ΔC e de intensidade intermediária para a linhagem WT. A segunda metodologia foi baseada no uso de uma molécula modelo para realizar experimentos e obter dados como parâmetros físico-químicos, o ácido láurico (ácido dodecanóico) foi escolhido por sua semelhança estrutural e facilidade de obtenção, curvas de calibração e experimentos de separação de moléculas com estrutura semelhante foram realizados com a técnica de eletroforese capilar. Uma terceira metodologia foi desenvolvida utilizando o padrão do ácido cis-11-metil-2-dodecenóico (DSF), curvas de calibração foram obtidas com o padrão isolado apresentando ótimas linearidades, tanto com a técnica de eletroforese capilar quanto com cromatografia líquida com detecção UV-Vis, experimentos de adição de padrão às amostras também foram executados. Os experimentos realizados com as amostras não apresentaram os resultados esperados, os problemas foram associados principalmente à quantidade de interferentes na amostra e a baixa concentração do analito nos cultivos, sendo que os métodos de extração realizados não foram suficientes para solucioná-los. O insucesso da técnica de voltametria cíclica foi associado ao envenenamento do eletrodo, devido à alta quantidade de compostos orgânicos presentes na amostra, e dúvidas relacionadas à eletroatividade do DSF. As dificuldades encontradas com a técnica de eletroforese capilar foram associadas à alta força iônica da amostra, presença de interferentes e baixa concentração do analito nos cultivos. Mesmo os experimentos realizados com cromatografia líquida acoplada a detecção com espectrometria de massas não atenderam às expectativas, dificultando a elucidação dos problemas encontrados até então e impossibilitando o desenvolvimento de uma metodologia que atendesse aos objetivos propostos. / Cis-11-methyl-2-dodecenoic acid, also known as DSF (autoinducer of the Quorum Sensing system used by the bacteria Xanthomonas axonopodis pv. citri) was explored as a study model for the cell secreted molecules analysis by electroanalytical techniques. Cell cultures from three different cell lines of the bacteria Xanthomonas axonopodis pv. citri were used for this study. A wild type (WT), which produced DSF in naturally observed quantities and two genetically modified ones. One of the lines (ΔC) had a genetic modification that resulted in an elevated production of DSF, and the other (ΔF) had a modification that stopped DSF production. Main analytical techniques used were: cyclic voltammetry, capillary electrophoresis and liquid chromatography (with UV-Vis detection and coupled with mass spectrometry), this last one was used with comparison purposes. Liquid-liquid extractions with organic solvents were realized as sample pre-treatment steps aiming the reduction of interfering species and analyte pre-concentration. Three main methodologies were adopted. One based in the differentiation of cell cultures analyzing or the cell culture supernatants or the resulting extracts from the pre-treatment steps. The main focus was the identification of a differential signal between the cultures that corresponded to the DSF quantities, in other words, null for the ΔF line, high intensity for the ΔC line and a an intermediary intensity for the WT line. The second methodology was based in experiments with a model molecule to obtain some data such as physical-chemistry parameters. Lauric acid (dodecanoic acid) was chosen for its structural similarity and easily acquisition. Calibration curves and similar structure molecules separation experiments were realized using capillary electrophoresis. Third and last methodology was developed using standard cis-11-methyl-2-dodecenoic acid (DSF). Calibration curves were obtained with the isolated standard showing great linearities using both capillary electrophoresis and liquid chromatography with UV-Vis detection. Experiments of standard addiction to the samples were also realized. Experiments using the samples did not show the expected results. Problems found were mainly associated with high amount of interfering species and low analyte concentration at the cultures, extraction methods used were not enough to solve this. The failures with the cyclic voltammetric techniques were associated to electrode poisoning, due to the high amount of organic compounds present at the sample, and DSF lack of electroactivity. Difficulties found with capillary electrophoresis were associated with the samples high ionic strength, presence of interfering species and low analyte concentration. Even liquid chromatography coupled with mass spectrometry experiments didn\'t attended the expectations. Making it difficult to elucidate the problems and not allowing the development of a methodology that could achieve the proposed objectives.
|
20 |
Desenvolvimento e aplicações de eletrodos de ouro confeccionados a partir de discos compactos graváveis (CD-Rs) / Development and applications of gold electrodes confectioned from recordable compact disc (CD-RS)Eduardo Mathias Richter 22 January 2001 (has links)
O presente trabalho descreve uma forma inédita e simples de construção de eletrodos de ouro (CDtrodos) a partir de discos compactos graváveis (CD-Rs). Os CD-Rs possuem em sua constituição uma película de ouro com uma espessura entre 50 e 100 nm e com área aproximada de 100 cm2. Esta superfície de ouro pode ser facilmente utilizada para construção de eletrodos convencionais usados em células estacionárias ou em células em fluxo. Além disso, a espessura nanométrica do filme de ouro também pode ser utilizada para construção de microeletrodos de banda com áreas inferiores a 10-6 cm2. Devido ao fato do CD-R ser produzido em escala comercial, o custo do mesmo é muito baixo, tornando possível sua utilização na forma de eletrodos descartáveis. Para comprovar a viabilidade da utilização destes filmes na confecção de eletrodos, seu desempenho foi comparado com o de eletrodo de ouro comercial, sendo observado um comportamento análogo. Diferentes maneiras de utilização do disco compacto gravável foram testadas, tanto em amostras sintéticas, como também, em amostras reais. Utilizando o método de redissolução potenciométrica à corrente constante (CCPSA), foram analisadas amostras de mercúrio em água potável e em água do mar, adaptando o CD-R a uma célula de injeção em fluxo. Nestes estudos, o limite de detecção de mercúrio situou-se em 250 ng L-1, utilizando-se tempo de deposição de 300 segundos. Estudos preliminares em células estacionárias levaram a limites de detecção inferiores. Em célula estacionária, foram realizadas análises de cobre em aguardente e em água potável. Em alguns casos, os resultados obtidos com as amostras reais foram comparados com outra técnica (E.A.A.), onde os resultados obtidos foram muito próximos a àqueles obtidos com os eletrodos de ouro. Análises em água de abastecimento, mostraram que em células estacionárias o limite de detecção para cobre situa-se em 30 ng L-1, para tempos de deposição de 600 segundos. / This work describes an original and novel form of construction of gold electrodes (CDtrodes) from recordable CDs (CD-Rs). The CD-Rs contain in its constitution a fine gold layer with a thickness from 50 to 100 nm and an approx. 100 cm2 of area. This surface can be easily used for construction of conventional electrodes for stationary or flow electrochemical cells. Moreover, the nanometer thickness of the gold film can be employed for the construction of microelectrodes with areas smaller than 10-6 cm2. Due to the fact that CD-Rs are produced on commercial scale, the cost of each unit is very low, a feature that enables the use of these electrodes in disposable form. To prove the suitability of these films to make gold electrodes, their performance was compared with the response of a commercial electrode, and a similar behavior was observed. Different applications of recordable compact disk were tested either with synthetic or real samples. Using the Constant-Current Potentiometric Stripping Analysis (CCPSA) method, mercury was analyzed in seawater and drinking water samples, fitting the CD-R to flow injection analysis cell. In these studies, the detection limit for mercury was found to be 250 ng L-1, with a deposition time of 300 seconds. Preliminary studies involving stationary cells allowed lower detection limits for mercury to be attained. With a stationary cell, the analyses of copper in sugar cane spirits and drinking water were carried out. In some instances, comparisons were made between this and another analytical technique (namely A.A.S.) where the results were very close with the ones obtained with the gold electrodes. Analysis of drinking water showed that for stationary cells the detection limit for copper is 30 ng L-1, with a deposition time of 600 s.
|
Page generated in 0.1078 seconds