• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 6
  • 1
  • Tagged with
  • 49
  • 18
  • 16
  • 13
  • 12
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Carbono modificado com nanopartículas superparamagnéticas como materiais estratégicos em química analítica e ambiental / Carbon modified with superparamagnetic nanoparticles as strategic materials in analytical and environmental chemistry

Alceu Totti Silveira Junior 19 September 2017 (has links)
O carbono, em suas muitas formas distintas, tem sido largamente empregado como material adsorvente, do tratamento de água à tecnologia industrial em virtude de sua boa performance, baixo custo e compatibilidades biológica e ambiental. Nesta tese foi verificada a associação sinérgica entre carvão ativo e nanopartículas superparamagnéticas de óxido de ferro ensejando a exploração entre a capacidade adsortiva e o magnetismo para o desenvolvimento de processos de remoção de contaminantes de meios aquosos e melhorando sua análise por meio de concentração magnética. Para este propósito, nanopartículas magnéticas recobertas com ácidos oleico ou esteárico foram especialmente preparadas e combinadas com carvão ativo em proporções variadas (1, 5, 10, 20, 25, 50 % m/m), seguindo rigoroso controle químico. Os materiais de carbono magnetizáveis mantém suas afinidades química e característica porosa do material precursor com alguma diminuição de sua área superficial, embora exibindo uma forte atração por campos magnéticos externos, permitindo sua fácil concentração e remoção. Estes materiais foram extensivamente caracterizados por técnicas como BET, FTIR, XRD, DLS, SEM, TG/DTA, VSM e SQUID. Por conveniência, o compósito a 10 % de nanopartículas de magnetita foi escolhido como o principal a ser utilizado na maioria das aplicações exibindo ampla área superficial (700 m2.g-1), volume e diâmetro médio de poro (0,487 cc.g-1 e 8,5 nm, respectivamente) e uma magnetização de saturação de 5 emu.g-1, com histerese desprezível à temperatura ambiente. Suas características adsorventes foram exploradas com sucesso na captura de corantes orgânicos (pararosanilina e azul de metileno), nitrobenzeno, bisfenol-A e BTEX (benzeno, tolueno, etilbenzeno e o,m,p-xilenos), bem como para íons de metais pesados como Hg(II), Pb(II) e Ag(I) em solução aquosa. Estudos eletroanalíticos foram feitos explorando o efeito de pré-concentração magnética na superfície do eletrodo após realizar estudos de adsorção envolvendo o levantamento de isotermas afim de investigar parâmetros como capacidade adsortiva e constantes de adsorção. Em todos os casos, um elevado aumento de aumento na sensibilidade foi obtido através do confinamento magnético em relação aos métodos convencionais. Desta forma, o emprego do compósito de carbono com nanopartículas de óxido de ferro superparamagnéticas demonstrou ser uma ferramenta poderosa a ser explorada em Química Analítica e Ambiental. / Carbon in many distinct forms has been widely employed as absorbing material in industrial and water technology because of its good performance, low cost and bio/environmental compatibility. In this doctoral thesis, a synergistic association of activated carbon with superparamagnetic Fe3O4 nanoparticles was carried out, aiming the exploitation of their combined absorption capability and magnetism, for developing new processes of removing contaminants from water and improving their analysis by means of magnetic concentration effect. For this purpose, magnetite nanoparticles coated with stearic or oleic acids were specially prepared and combined with activated carbon, at several proportions (1, 5, 10, 20, 25, 50 % m/m), following a rigorous chemical and analytical control. The magnetized carbon materials kept the original porous characteristics and molecular affinity of the original absorber, with some decrease of the active surface area, but exhibiting a strong attraction by the magnetic field, allowing their easy concentration and removal. Such materials were extensively characterized by BET, FTIR, XRD, DLS, SEM, TG/DTA, VSM and SQUID techniques. For convenience, the carbon material containing 10 % of magnetite was elected as principal, exhibiting a surface area of 700 m2 g-1, average volume and porous diameter of 0,487 cm3 g-1 and 8,5 nm, respectively, and a saturation magnetization of 5 emu g-1, with null hysteresis at room temperature. Its absorbing characteristics were successfully explored for the capture of organic dyes (pararosaniline, and methylene blue), bisphenol-A, and BTEX (benzene, toluene, ethylbenzene, and o,m,p-xilene), as well as hazardous, heavy metal ions, such as Hg(II), Pb(II) and Ag(I) in aqueous solution. Electroanalytical studies were carried out by exploring the magnetic pre-concentration effect on the electrodes, after performing a detailed adsorption study involving the construction of isotherms, in order to evaluate the equilibrium and mass capacity parameters. In all the cases, a great increase of sensitivity was attained by the magnetic confined method, in relation to the conventional methods. In this way, the use of carbon with superparamagnetic nanoparticles demonstrated a powerful strategy to be explored in environmental and analytical chemistry.
42

Eletrodos modificados pela codeposição eletroquímica de metais e óxidos de molibdênio: estrutura, composição e propriedades / Electrodes modified by the electrochemical codeposition of metals and molybdenum oxides: Structure, composition and properties

Luís Kosminsky 23 October 2003 (has links)
Filmes de óxidos de molibdênio, com ou sem a inclusão de metais, foram eletroquimicamente depositados sobre eletrodos de carbono vítreo em solução de Mo(VI) com pH ajustado em 2,5 ou 3,0. Estes filmes foram caracterizados por Soft X-ray Spectroscopy (SXS), X-ray Diffraction (XRD) e Rutherford Backscattering Spectroscopy (RBS). A coordenação local dos sítios de Mo foram analizadas. As configurações estruturais locais do Mo foram avaliadas quando diferentes números de ciclos de potencial foram empregados na modificação dá superfície do eletrodo. Alguns metais (Pt, Pd, Rh e Cu) foram codepositados com as espécies de Mo e seu efeito nos materiais obtidos foi investigado. O grau de ocupação do orbital 4d do Mo foi examinado como um indicador da existência de interações entre o Mo e o metal codepositado. A incorporação de Pt no filme de óxidos na superfície de um eletrodo de ouro foi caracterizada por espectroscopia PIXE. O eletrodo modificado por óxidos de molibdênio foi estudado em faixas de potencial positivas frente à oxidação de nitrito (NO2-) e de óxido nítrico (NO). A relação entre a porosidade do filme e a presença de água em seus interstícios foi examinada e a capacidade de retenção de NO e NO2 foi também investigada. O eletrodo modificado foi usado como um sensor amperométrico em um sistema de injeção em fluxo (FIA) e o método foi empregado na determinação de nitrito em amostras de lingüiça. A oxidação de H2O2 foi investigada em superfície recoberta por filme de óxidos de Mo com Pt codepositada. O efeito do pH, do potencial e do tempo de pré-redução do filme de Pt e MoOx foi discutida. O comportamento eletroquímico dos filmes codepositados de Rh, Pd, Pt ou Cu e MoOx foi caracterizados comparativamente pela redução do iodato e pela oxidação do nitrito e do etanol nestes substratos. H4MogO26 foi empregado para preparar filmes contendo molibdênio e sua resposta eletroquímica foi comparada com as obtidas com o filme depositado por procedimento usual. O filme de óxidos de molibdênio foi usado com sucesso na imobilização de um complexos de Ru(III) na superfície de carbono vítreo. / Molybdenum oxide films with and without metal inclusion were electrochemically deposited on glassy carbon electrodes from Mo(VI) solutions at pH 2.5 or pH 3.0. These films were characterized by Soft X-ray Spectroscopy (SXS), X-ray Diffraction (XRD) and Rutherford Backscattering Spectroscopy (RBS). The local coordination of Mo sites was analyzed. The Mo local structure configurations were evaluated when different number of potential cycles were employed in the modification of the electrode surface. Some metaIs (Pt, Pd, Rh and Cu) were codeposited with the Mo species and their effect on the obtained material was investigated. The occupancy leveI of the 4d orbital of Mo was examined as an indicator of interactions between Mo and codeposited metals. The incorporation of Pt in the oxide film at a gold electrode surface was characterized by PlXE spectroscopy. The electrode modified by molybdenum oxides was studied at positive potential ranges for the oxidation of nitrite (NO2-) and nitric oxide (NO). The relationship between the porosity of the film and its water content was exarnined and the entrapment of NO and NO2 was also investigated. The modified electrode was used as an amperometric sensor in a flow injection configuration and the method was employed in the deterrnination of nitrite in sausage samples. The oxidation of H2O2 was investigated at surfaces covered by the Mo filrn with codeposited Pt. The effect of pH and potential and time of pre-reduction on the response of the film with Pt was discussed. The electrochemical behaviour of codeposited films of Rh, Pd, Pt or Cu and Mo MoOx was characterized comparatively for the reduction of iodate and the oxidation of nitrite and ethanol. 4MogO26 was also employed to prepare films containing molybdenum and their electrochemical responses were compared with those obtained by using the film electrodeposited by the usual procedure. The molybdenum oxide film was successfully used for the immobilization of Ru(III) complex at glassy carbon surfaces.
43

Uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas / Use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry

Allan Cezar Vieira dos Santos 09 June 2006 (has links)
Esta dissertação descreve o uso de técnicas eletroanalíticas em fluxo no estudo da adsorção de Cd(II), Pb(II) e Cu(II) em vermiculita visando tratamento alternativo para efluentes da indústria de tintas. O estudo indicou que na faixa de pH entre 4 e 6 não há diferença entre a utilização de vermiculita expandida ou não-expandida na remoção dos íons. Observou-se que nos pH\'s avaliados o tempo de interação de 180 minutos foi suficiente para que o sistema atingisse o equilíbrio. Pode-se afirmar que a vermiculita não expandida apresenta as seguintes ordens de afinidade pelo cátions considerados: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). Nas condições de trabalho, os ensaios envolvendo a coluna de vermiculita não evidenciaram uma melhor capacidade de extração dos íons estudados frente ao sistema de extração em batelada. Percentuais de extração da ordem de 76% em amostra de efluente no sistema em batelada reforçam a viabilidade do uso da vermiculita como adsorvente destes metais. Um método SIA-ASV (análise por injeção seqüencial - voltametria de redissolução anódica) foi proposto e validado. Para um tempo de deposição de 80 s e vazão de 10 µLs-1, os limites de detecção foram 0,06, 0,09 e 0,16 µmolL-1 para Cd, Pb e Cu, respectivamente, além de apresentar uma faixa linear de trabalho entre 0,2 e 9,0 µmolL-1. / This dissertation describes the use of flow electroanalytical techniques to study the adsorption of Cd(II), Pb(II) and Cu(II) onto vermiculite aiming an alternative treatment of wastewater from coatings industry. The study indicated that under pH range from 4 to 6 there is no difference on using expanded or not expanded vermiculite for removal of ions. It was also observed that at any evaluated pH, a 180 minutes interaction time was long enough to allow the system reach equilibrium. It\'s possible to state that non-expanded vermiculite presents the following affinity orders by the studied ions: pH 4: Cu(II) < Cd(II) < Pb(II); pH 5: Cu(II) ? Cd(II) < Pb(II); pH 6: Cd(II) < Cu(II) < Pb(II). At working conditions, tests involving vermiculite columns didn\'t show a better performance on extracting these ions when faced to batch extraction systems. Extraction percentuals of about 76% were obtained using a sample of coatings industry wastewater, reinforcing the viability of the use of vermiculite as an adsorbent of these metals. A SIA-ASV (sequential injection analysis - anodic stripping voltammetry) method was proposed and validated. For a deposition time of 80 s and a flow rate of 10 µL s-1, detection limits were 0.06, 0.09 and 0.16 µmol L-1 to Cd, Pb and Cu, respectively; a linear working range, between 0.2 and 9.0 µmol L-1 was also determined.
44

Desenvolvimento de eletrodos de pasta de carbono modificados com filmes de azul da prússia / Development of carbon paste electrodes modified with Prussian Blue films

Viviane Midori Ivama 24 February 2003 (has links)
Os eletrodos de pasta de carbono modificados com Azul da Prússia foram preparados usando a voltametria cíclica, deposição a um potencial controlado e a deposição a dois potenciais controlados. O último método foi melhor e produziu eletrodos modificados com alta sensibilidade e estabilidade durante a redução catalítica de peróxido de hidrogênio. A composição da solução modificadora foi 3,0 mmol L-1 de FeCl3 e 2,0 mmol L-1 de K3[Fe(CN)6] em pH 2,0 com HCI. O sistema de eletrodos foi imerso na solução modificadora e + 0,4 V foi aplicado no eletrodo de trabalho durante 2 minutos. Depois, o potencial foi revertido para - 0,4 V por mais 2 minutos. O processo total foi repetido mais duas vezes. Além disso, para melhorar a estabilidade dos eletrodos de pasta de carbono modificados com Azul da Prússia (EPC-AP), estes foram ciclados em solução contendo 1,0 m mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI na faixa de potencial - 0,4V &#8804; Eapl &#8804; 0,6V a 60 mV s-1 (50 ciclos). Estes eletrodos, denominados de EPC-AP-Rh, foram secos a temperatura ambiente por 24 horas antes de serem utilizados. Os EPC-AP-Rh apresentaram boa estabilidade durante sucessivos ciclos, com os picos anódico e catódico, referentes a 0,30 V e 0,18 V inicialmente atribuídos para um processo redox envolvendo Branco da Prússia / Azul da Prússia. Cálculos com (Ep,a + Ep,c / 2), é 0,24 V. Em solução tampão citrato de potássio / ácido cítrico contendo 0,5 mol L-1 de KCI, pH 6,1, as correntes de picos variam linearmente com a velocidade de varredura 0,025 Vs-1 &#8804; &#957; &#8804; 0,400 V s-1 mostrando que o processo é governado por difusão de íons do eletrólito suporte para a superfície do eletrodo (durante a etapa de redução) ou do eletrodo para a solução (durante a etapa de oxidação) para manter a eletroneutralidade. O excesso superficial foi 4,3 10-8 mol cm-2, calculado usando a carga anódica obtida pelo voltamograma cíclico, depois da subtração do fundo de carga referente a um eletrodo não modificado de pasta de carbono em solução eletrólito suporte (1,0 x 10-3 mol L-1 de RhCl3, 0,05 mol L-1 de KCI e 0,02 mol L-1 de HCI, &#957; = 60 mV s-1). O eletrólito suporte usado para detecção para determinação de peróxido de hidrogênio foi o tampão10 mmol L-1 de citrato de potássio/ 2 mmol L-1 de ácido cítrico, pH 6,1 (força iônica= 0,16 mol L-1) contendo 0,5 mol L-1 de KCI. A ausência deste eletrólito ou a presença de íons fosfatos diminui a estabilidade deste sensor. Peróxido de hidrogênio foi determinado a 0,04 V (vs EAg/AgCI, KCI sat) na faixa linear de 5,1 x 10-5 mol L-1 a 8,6 x 10-4 mol L-1 com sensibilidade média de 1,4 &#177; 0,2 A mol-1 L cm-2 e limite de detecção de (2,5 &#177; 0,02) x 10-5 mol L-1. Neste potencial aplicado a contribuição da corrente de redução do oxigênio foi de 8,0 % na presença de 1,0 mmol L-1 de H2O2. Curvas analíticas obtidas durante a determinação de peróxidos de hidrogênio ao longo de 5 dias, cada curva analítica representa uma média de 6 curvas amperométricas consecutivas, que desempenhou em cada dia, apresentando uma diminuição de somente 27% na sensibilidade do eletrodo modificado. Quando fora de uso o eletrodo foi armazenado em solução 0,5 mol L-1 de KCI. A um potencial aplicado de 0,04 V não foi detectada uma interferência do mediador ou oxidação direta do ácido úrico. A interferência de ácido ascórbico foi apenas significativa para potenciais iguais ou superiores a 0,060 V. / Prussian Blue carbon paste modified electrodes were prepared using cyclic voltammetry and deposition atone and two controlled potentials. The last method was the best and produced modified electrodes with higher sensitivity and stability during the catalytic reduction of hydrogen peroxide. The composition of the modifying solution was 3.0 mmol L-1 FeCl3, 2.0 mmol L-1 K3[Fe(CN)6] in pH 2.0 with HCI. The electrode system was immersed in the modifying solution and + 0.4 V was applied to the working electrode during two minutes. After, the potential was just reverted to - 0.4 V once more two minutes. The total process was repeated twice. Further, to improve the stability of the Prussian Blue carbon paste modified electrodes (PB-CPME), they were cycled in a solution containing 1.0 mmol L-1 RhCl3, 0,05 mol L-1 KCI and 0.02 mol L-1 HCI in a - 0.4 &#8804; E &#8804; 0.6 V potential range at 60 mV s-1 (50 cycles). These electrodes, denominated of Rh-PBCPME, were dried at ambient temperature during 24 hours before use. The Rh-PBCPME shows good stability during successive cycles, with anodic and cathodic peaks recorded at 0.30 V and 0.18 V being attributed to a redox process involving Prussian White / Prussian Blue couple. Em, calculated as (Ep,a + Ep,c/2), is 0.24 V. In potassium citrate/ citric acid buffer solution containing 0.5 mol L-1 KCI, pH 6.1, the peak currents changed linearly with the square of sweep velocity in the range 0.025 Vs-1 &#8804; v &#8804; 0.400 Vs-1 showing that the process is governed by ion diffusion from support electrolyte to the electrode surface (during the reduction step) or from the electrode to the solution (during the oxidation step) to ensure the electroneutrality rule. The modifier surface excess was 4.3 x 10-8 mol cm-2, calculated using the anodic charge obtained from cyclic voltammograms, after subtraction of the background charge recorded with an unmodified carbon paste electrode in an electrolyte support solution (1.0 mmol L-1 RhCl3, 0.5 mol L-1 KCI and 0.02 mol L-1 HCI, v = 60 mV s-1). The supporting electrolyte used to detection of hydrogen peroxide was 10 mmol L-1 potassium citrate/ 2 mmol L-1 Citric acid buffer, pH 6.1 (ionic strength = 0.16 mol L-1) containing 0.5 mol L-1 KCI. The absence of this electrolyte or the presence of phosphate ions decreased the stability of the sensor. Hydrogen peroxide was detected at 0.04V (vs EAg/AgCI, KCI sat) in 5.1 x 10-5 - 8.6 x 10-4 mol L-1 linear range with sensitivity of 1.4 &#177; 0.2) A mo1-1 L cm-2 and detection limit of (2.5 &#177; 0.02) x 10-5 mol L-1. At this applied potential the contribution of oxygen reduction current was 8.0 % in the presence of 1.0 mmol L-1 H2O2. Analytical curves obtained during hydrogen peroxide detections along 5 days, ach one of them representing an average of 6 consecutive amperometric analytical curves, carried out in the same day, showed a decrease of only 27 % in the sensitivity of the modified electrodes. When was not using the electrode was kept, 0.5 mol L-1 KCI. At 0.04 V applied potential no interference was detected due to mediated or direct oxidation of uric acid. The interference of ascorbic acid was only significant to 0.060 V or higher applied potentials.
45

Esudo do aço inoxidável especial UNS S31254 visando seu emprego em técnicas eletroanalíticas / Study of special stainless steel UNS S31254 aiming its use in electroanalytical techniques

Lúcia Helena Terra 19 August 2004 (has links)
O aço especial UNS S31254 (aço 254), um aço inoxidável austenítico contendo 20,1% de cromo, 18,4% de níquel e 6,42% de molibdênio foi estudado com o objetivo de ser aplicado em técnicas eletroanalíticas, tais como a potenciometria, a condutimetria e como eletrodo indicador em medidas de pH. Os estudos eletroanalíticos foram precedidos de curvas de polarização potenciostáticas e potenciodinâmicas e de ensaios não eletroquímicos (FTICR, MEV e XPS), em que se caracterizou a presença do filme passivante. Grande parte dos estudos incluíram, para efeito de comparação, os aços UNS S 31603 (aço 316 L) e UNS S31678 (aço F 138), o primeiro de largo emprego comercial e o último, aplicável em implantes ortopédicos. Os estudos, realizados a 25° C, se iniciaram com a caracterização eletroquímica dos referidos materiais imersos em meios aquosos de ácidos clorídrico, acético, nítrico, sulfúrico e galacturônico, e dos sais cloreto de sódio, sulfato de sódio e nitrato de sódio, variando-se a concentração do eletrólito. O aço 254 se mostrou passivado, na grande maioria dos meios estudados, em toda a faixa de potenciais que se estende do potencial de corrosão (Ecorr, potencial de circuito aberto estacionário) até o potencial de transpassivação (onde ocorre o rompimento do filme e, na maioria dos meios, a oxidação generalizada da superfície e a reação H2O/O2). Em meio de ácido acético a faixa de potencial em que o referido aço se mantém passivado é a mais ampla, indicando que o rompimento do filme passivo exige maior energia, em virtude do maior teor de molibdênio superficial detectado por MEV. A corrosão por pite foi observada em meios de HCI e de NaCI a potenciais mais positivos do que o de transpassivação. A caracterização da superfície por MEV mostrou que as inclusões presentes no aço são constituídas basicamente de óxidos de alumínio e de cálcio. A análise por XPS da superfície do aço 254 apenas polido e exposto ao ar revelou a presença de Mo (VI) na superfície; em meio de NaCI 0,15 mol L-1 há o enriquecimento gradual de Mo (VI) quando se varia o potencial desde o Ecorr, passando por um potencial passivo e se estendendo a um potencial 50 mV acima do potencial de transpassivação. O aço 254 pode ser empregado em substituição à platina em todas as determinações eletroanalíticas realizadas neste trabalho, envolvendo titulações potenciométricas, medidas condutimétricas e determinação de pH. Em medidas de pH em sistemas com força iônica mais baixa, entretanto, é necessário um controle mais adequado do tratamento superficial, além dos realizados neste trabalho, para que a resposta do petencial seja mais rápida. Estes estudos podem contribuir para baixar o custo de análises industriais e de experimentos que venham a ser realizados em laboratórios diáticos. / Special UNS S31254 stainless steel (254 SS), an austenitic stainless steel with 20.1% Cr, 18.4% Ni and 6.42% Mo has been studied in order to be applied in electroanalytical techniques as potentiometry, conductimetry and as a sensor in pH measurements. The electroanalytical studies were preceded of potentiostatic and potentiodynamic polarization curves. The surface characterization was made using FTCIR, SEM and XPS as techniques. The studies have included, for comparison, UNS S 31603 (316 L SS) and UNS S31678 (F 138 SS); the former is commercially employed in a large extension and the latter is applicable in orthopedic implants. The experiments were made at 25° C, beginning with the electrochemical characterization of the ferrous materiais in different aqueous media: chloridric, acetic, sulfuric, nitric and D-galacturonic acids and saline solutions of sodium chloride, sodium sulfate and sodium nitrate, changing the electrolyte concentration. SS 254 is passivated in most of the studied media, on the entire potential range analyzed (from corrosion potential to transpassivation potential). In acetic media it was observed the largest potential range where 254 SS is passivated, indicating that a higher energy is necessary to disrupt the passivant film, due to a higher Mo concentration at the surface, detected using SEM. Pitting corrosion was observed in HCl and NaCl media at potential more positive than Etr. SEM surface characterizations have shown aluminium oxide and calcium oxide inclusions. XPS analyses have indicated the presence of Mo (VI) on the polished surface and that there is a gradual Mo (VI) increasing, in solution, when the potential changes from Ecorr to E > Etr. 254 SS can be used in potentiometric and conductimetric titrations and as a sensor electrode for pH measurements. However, in biological applications a more adequate surface treatment is needed in order to obtain rapid responses. Overall the results suggest that 254 can be used as substitute of platinum in different electroanalytical techniques. This finding contributes to lower the cost of experiments to be performed in didactic laboratories and/or industrial analyses.
46

Desenvolvimento de métodos eletroanalíticos (análise por redissolução e eletroforese capilar) para a determinação de metais e ânions em combustíveis e derivados de petróleo / Development of electroanalytical methods (Stripping Analysis and Capillary Electrophoresis) for the determination of metals and anions in fuels and petroleum-based products

Muñoz, Rodrigo Alejandro Abarza 15 March 2006 (has links)
Neste trabalho foram desenvolvidos métodos eletroanalíticos (redissolução potenciométrica e voltamétrica) para a determinação de metais (mercúrio, cobre, chumbo e zinco) em petróleo, óleo diesel, óleo lubrificante e álcool combustível. Para analisar álcool, foi também desenvolvido um método por eletroforese capilar, que possibilita a determinação de cátions (sódio, potássio e cálcio) e ânions (cloreto, sulfato e nitrato). Procedimentos envolvendo a utilização de fornos de microondas (focalizadas - que opera a pressão atmosférica - e com cavidade, que promove a digestão em frascos pressurizados) para a decomposição de petróleo, óleo diesel e óleo lubrificante são descritos. As determinações de cobre e mercúrio por redissolução potenciométrica apresentaram melhores limites de detecção do que a voltametria de redissolução de onda quadrada nas amostras digeridas, utilizando eletrodos de ouro confeccionados a partir de CDs graváveis (Cdtrodos), como eletrodo de trabalho. Para a determinação de chumbo e zinco nas mesmas amostras digeridas, os melhores resultados foram obtidos com eletrodos de filme de mercúrio e utilizando a voltametria de redissolução potenciométrica. Perdas de mercúrio por volatilização foram verificadas quando as amostras foram digeridas em fornos de microondas focalizadas. Para os demais metais, a utilização deste forno foi vantajosa por proporcionar melhores limites de detecção devido à utilização de maiores massas de amostra no processo de digestão. A utilização de um banho ultrassônico de bancada para promover a extração de cobre e chumbo de óleos lubrificantes na presença da mistura 1:1 (v/v) de HClconc. e H2O2 (30% m/v) mostrou-se eficiente. Trinta minutos de exposição à energia ultrassônica foram necessários para a extração quantitativa de ambos os metais. Nas soluções extratoras, o teor dos metais foi determinado por voltametria de redissolução anódica, usando CDtrodos. Os limites de detecção do método para a determinação de cobre e chumbo foram, respectivamente, de 23 e 67 ng g-1 de óleo, aplicando 120 s de tempo de deposição. A voltametria de redissolução anódica em eletrodo de ouro possibilitou a determinação de cobre e chumbo em álcool combustível, sem qualquer tratamento prévio das amostras. Limites de detecção de 120 e 235 ng L-1 para cobre e chumbo, respectivamente, foram obtidos aplicando 15 min de tempo de deposição. Alternativamente, a evaporação do etanol seguido da redissolução em água desionizada permitiu a determinação dos metais por análise de redissolução. Todos os resultados obtidos utilizando diferentes metodologias de decomposição de amostras foram comparados com os resultados obtidos por análises por espectrometria de absorção atômica com forno de grafite. O método envolvendo a evaporação prévia, seguida da redissolução dos íons em meio aquoso também se mostrou muito favorável para realizar a determinação de cátions e ânions por eletroforese capilar em amostras de etanol hidratado combustível. Os íons Na+, K+ e Ca2+, Cl-, NO3- e SO42- foram encontrados nas amostras analisadas. Os limites de detecção destes íons se encontram na faixa de 0,06 e 0,18 mg L-1. / In this work eletroanalytical methodologies (potentiometric stripping analysis and anodic stripping voltammetry) for the determination of metals (mercury, copper, lead, and zinc) in crude oil, lubricating oil, diesel fuel, and ethanol fuel are proposed. A capillary electrophoresis method for ethanol fuel was developed to determine cations (sodium, potassium, and calcium) and anions (chloride, sulphate, and nitrate). Microwave digestion methods using different ovens (a focused microwave oven – operating at atmospheric pressure, and a cavity microwave oven, which employs pressurized vessels) for crude oil, lubricating oil, and diesel fuel are described. The determination of copper and mercury by potentiometric stripping analysis presents better detection limits than stripping voltammetric determinations for the digested sample analysis. Loss of mercury by volatilization was verified when samples were digested in the focused microwave oven. Otherwise, this oven presented some advantages for the other metals, as the improved detection limits due to the employment of higher sample mass for the digestion process. The use of a ultrasonic bath to promote the extraction of copper and lead from lubricating oils in the presence of 1:1 (v/v) HClconc and H2O2 (30% m/v) was efficient. Thirty minutes of ultrasonic exposure were necessary for quantitative exctraction of copper and lead. Anodic stripping voltammetry using gold CDtrodes was applied for metal determination in the extracted solutions. The detection limits of the proposed method for copper and lead were 23 and 67 ng g-1, respectively, under application of 120 seconds as deposition time. Anodic stripping voltammetry at a gold electrode was used for the determination of copper and lead in ethanol fuel, without any prior sample treatment. Detection limits of 120 and 235 ng L-1 for copper and lead, respectively, were attained applying 900 s as deposition time. Alternatively, the ethanol evaporation followed by re-suspension in deionised water allowed the metals determination by stripping analysis. All results obtained for sample decomposition methods were compared with the ones obtained by electrothermal atomic absorption spectrometric determinations. The method, which employs prior ethanol evaporation followed by re-suspension in deionised water, was applied for the determination of cations and anions by capillary electrophoresis in the hydrated ethanol fuel (automotive fuel). Na+, K+, Ca2+, Cl-, NO3-, and SO42- ions were found in the analyzed samples. The detection limits for these ions were situated between 0.06 and 0.18 mg L-1.
47

Development of new types of composite electrodes based on natural clays and their analytical applications / Développement de nouveaux types d'électrodes composites à base d'argiles naturelles et leurs applications analytiques

Maghear, Adela 12 November 2013 (has links)
Le travail de thèse est consacré au développement d'électrodes composites à base d'argiles naturelles et à leur caractérisation électrochimique à des fins analytiques, notamment pour le dosage de cations métalliques (Cu2+) et de quelques substances à visée thérapeutique. Le premier chapitre expérimental est consacré à une étude comparée des caractéristiques chimiques, structurales et physico-chimiques de deux argiles naturelles extraites sur deux sites en Roumanie. Il apparaît que l'argile de Valea Chioarului, de type montmorillonite, présente les propriétés les plus intéressantes avec une surface spécifique importante (190 m2/g). Le deuxième chapitre fait état d'une analyse prospective des deux argiles comme matériaux d'électrodes en utilisant un film composite argile/poly-électrolyte. Trois molécules d'intérêt pharmaceutique ont été choisies pour cible, l'acide ascorbique, la riboflavine et l'acétaminophène. Cette dernière molécule peut être détectée soit par oxydation directe, soit via une réaction électro-enzymatique avec la peroxydase de raifort. Les troisième et quatrième chapitres sont consacrés à l'utilisation d'argiles échangées par des cations ammonium pour la détection du cuivre. Ainsi, l'argile de Valea Chioarului a été échangée partiellement avec du tétrabutylammumium. La perméabilité des films d'organo-argile recouverts d'un film de cellulose a été étudiée en utilisant différentes sondes électro-actives de charge différentes, Ru(NH3)63+, [Fe(CN)6]3-, Fc(MeOH)2. Les conditions expérimentales ont été ensuite optimisées pour la détection du Cu(II) et Cd(II) avec ces électrodes modifiées en voltammétrie à vague carrée. Dans le dernier chapitre, une configuration originale d'électrode modifiée a été mise au point. Il s'agit d'électrodes composites argile-silice mésoporeuse préparée par électrodéposition en présence ou non d'un tensioactif, le cétyltriméthylammonium. La perméabilité des films a également été étudiée avec les mêmes molécules que précédemment. Il apparait que l'extraction du tensio-actif conduit à des films homogènes très poreux et stables qui présentent des propriétés d'accumulation du Cu(II) / The thesis is devoted to the development of composite electrodes based on natural clays and their electrochemical characterization for analytical purposes, in particular for the determination of metal cations (Cu2+) and some therapeutic substances. The first experimental chapter is devoted to a comparative study of the chemical, structural and physico-chemical properties of two natural clays extracted from two sites in Romania. It appears that Valea Chioarului clay, of montmorillonite type, has the most interesting properties with a high specific surface area (190 m2/g). The second chapter presents a prospective analysis of the two clays as electrode materials using a clay/polyelectrolyte composite film. Three target molecules of pharmaceutical interest have been selected: ascorbic acid, riboflavin, and acetaminophen. This last molecule can be detected either by direct oxidation or through an electro-enzymatic reaction with horseradish peroxidase. The third and fourth chapters are devoted to the use of clays exchanged by ammonium cations for copper detection. Thus, Valea Chioarului clay was partially exchanged with tétrabutylammumium. The permeability of the organoclay films coated with a cellulose membrane was studied by using different electroactive probes of different charging, Ru(NH3)63+, [Fe(CN)6]3-, Fc(MeOH)2. The experimental conditions were then optimized for the detection of Cu (II) and Cd (II) with the modified electrodes by square wave voltammetry. In the last chapter, an original modified electrode configuration was developed. This implies composite mesoporous silica-clay electrodes prepared by electrodeposition in the presence or absence of a surfactant, like cetyltrimethylammonium. The permeability of the films was also investigated with the above mentioned molecules. It appears that the extraction of the surfactant leads to very stable and homogeneous porous films that show Cu (II) accumulation properties
48

Desenvolvimento de métodos eletroanalíticos (análise por redissolução e eletroforese capilar) para a determinação de metais e ânions em combustíveis e derivados de petróleo / Development of electroanalytical methods (Stripping Analysis and Capillary Electrophoresis) for the determination of metals and anions in fuels and petroleum-based products

Rodrigo Alejandro Abarza Muñoz 15 March 2006 (has links)
Neste trabalho foram desenvolvidos métodos eletroanalíticos (redissolução potenciométrica e voltamétrica) para a determinação de metais (mercúrio, cobre, chumbo e zinco) em petróleo, óleo diesel, óleo lubrificante e álcool combustível. Para analisar álcool, foi também desenvolvido um método por eletroforese capilar, que possibilita a determinação de cátions (sódio, potássio e cálcio) e ânions (cloreto, sulfato e nitrato). Procedimentos envolvendo a utilização de fornos de microondas (focalizadas - que opera a pressão atmosférica - e com cavidade, que promove a digestão em frascos pressurizados) para a decomposição de petróleo, óleo diesel e óleo lubrificante são descritos. As determinações de cobre e mercúrio por redissolução potenciométrica apresentaram melhores limites de detecção do que a voltametria de redissolução de onda quadrada nas amostras digeridas, utilizando eletrodos de ouro confeccionados a partir de CDs graváveis (Cdtrodos), como eletrodo de trabalho. Para a determinação de chumbo e zinco nas mesmas amostras digeridas, os melhores resultados foram obtidos com eletrodos de filme de mercúrio e utilizando a voltametria de redissolução potenciométrica. Perdas de mercúrio por volatilização foram verificadas quando as amostras foram digeridas em fornos de microondas focalizadas. Para os demais metais, a utilização deste forno foi vantajosa por proporcionar melhores limites de detecção devido à utilização de maiores massas de amostra no processo de digestão. A utilização de um banho ultrassônico de bancada para promover a extração de cobre e chumbo de óleos lubrificantes na presença da mistura 1:1 (v/v) de HClconc. e H2O2 (30% m/v) mostrou-se eficiente. Trinta minutos de exposição à energia ultrassônica foram necessários para a extração quantitativa de ambos os metais. Nas soluções extratoras, o teor dos metais foi determinado por voltametria de redissolução anódica, usando CDtrodos. Os limites de detecção do método para a determinação de cobre e chumbo foram, respectivamente, de 23 e 67 ng g-1 de óleo, aplicando 120 s de tempo de deposição. A voltametria de redissolução anódica em eletrodo de ouro possibilitou a determinação de cobre e chumbo em álcool combustível, sem qualquer tratamento prévio das amostras. Limites de detecção de 120 e 235 ng L-1 para cobre e chumbo, respectivamente, foram obtidos aplicando 15 min de tempo de deposição. Alternativamente, a evaporação do etanol seguido da redissolução em água desionizada permitiu a determinação dos metais por análise de redissolução. Todos os resultados obtidos utilizando diferentes metodologias de decomposição de amostras foram comparados com os resultados obtidos por análises por espectrometria de absorção atômica com forno de grafite. O método envolvendo a evaporação prévia, seguida da redissolução dos íons em meio aquoso também se mostrou muito favorável para realizar a determinação de cátions e ânions por eletroforese capilar em amostras de etanol hidratado combustível. Os íons Na+, K+ e Ca2+, Cl-, NO3- e SO42- foram encontrados nas amostras analisadas. Os limites de detecção destes íons se encontram na faixa de 0,06 e 0,18 mg L-1. / In this work eletroanalytical methodologies (potentiometric stripping analysis and anodic stripping voltammetry) for the determination of metals (mercury, copper, lead, and zinc) in crude oil, lubricating oil, diesel fuel, and ethanol fuel are proposed. A capillary electrophoresis method for ethanol fuel was developed to determine cations (sodium, potassium, and calcium) and anions (chloride, sulphate, and nitrate). Microwave digestion methods using different ovens (a focused microwave oven – operating at atmospheric pressure, and a cavity microwave oven, which employs pressurized vessels) for crude oil, lubricating oil, and diesel fuel are described. The determination of copper and mercury by potentiometric stripping analysis presents better detection limits than stripping voltammetric determinations for the digested sample analysis. Loss of mercury by volatilization was verified when samples were digested in the focused microwave oven. Otherwise, this oven presented some advantages for the other metals, as the improved detection limits due to the employment of higher sample mass for the digestion process. The use of a ultrasonic bath to promote the extraction of copper and lead from lubricating oils in the presence of 1:1 (v/v) HClconc and H2O2 (30% m/v) was efficient. Thirty minutes of ultrasonic exposure were necessary for quantitative exctraction of copper and lead. Anodic stripping voltammetry using gold CDtrodes was applied for metal determination in the extracted solutions. The detection limits of the proposed method for copper and lead were 23 and 67 ng g-1, respectively, under application of 120 seconds as deposition time. Anodic stripping voltammetry at a gold electrode was used for the determination of copper and lead in ethanol fuel, without any prior sample treatment. Detection limits of 120 and 235 ng L-1 for copper and lead, respectively, were attained applying 900 s as deposition time. Alternatively, the ethanol evaporation followed by re-suspension in deionised water allowed the metals determination by stripping analysis. All results obtained for sample decomposition methods were compared with the ones obtained by electrothermal atomic absorption spectrometric determinations. The method, which employs prior ethanol evaporation followed by re-suspension in deionised water, was applied for the determination of cations and anions by capillary electrophoresis in the hydrated ethanol fuel (automotive fuel). Na+, K+, Ca2+, Cl-, NO3-, and SO42- ions were found in the analyzed samples. The detection limits for these ions were situated between 0.06 and 0.18 mg L-1.
49

Interfacial Phenomena at the Graphene-Liquid-Interface in Nanostructure Devices: Faradaic Effect, Edge-Gating and Van Der Waals Heterostructures

Neubert, Tilmann Joachim 03 February 2022 (has links)
In dieser Arbeit werden verschiedene Aspekte des Designs und der Funktionsweise von in Flüssigkeit betriebenen Graphen-basierten Sensoren untersucht, wodurch neue Einblicke in grundlegende Prozesse an der Graphen-Flüssigkeits-Grenzfläche gewonnen werden. Zunächst wird die Wirkung redoxaktiver Moleküle in der Elektrolytlösung in elektrochemisch gesteuerten Graphen-FETs untersucht. Während des Betriebs kann ein heterogener Elektronentransfer stattfinden, der zu Faradayschen Strömen am Graphenkanal führt. Diese führen zu Verschiebungen der Transferkurve von Graphen, da die Graphen-Flüssigkeits-Grenzfläche eine nur teilweise polarisierbare Elektrode darstellt. Dies wird als „Faradayscher Effekt“ bezeichnet. Er unterscheidet sich grundlegend von typischen Transduktionsmechanismen. Parameter, die den Faradayschen Effekts beeinflussen, werden detailliert untersucht. So sind die Verschiebungen z.B. abhängig von der Graphenkanalfläche. Der zweite Abschnitt konzentriert sich auf die Kante von Graphen, die einen nanoskopischen eindimensionalen Defekt des zweidimensionalen Materials darstellt. In dieser Arbeit wird ein neuer Graphen-FET vorgestellt, der auf der Steuerung von Graphen nur über die elektrochemische Doppelschicht an der Kante basiert. Um dies zu erreichen, wird der basale Teil des Graphens durch eine Passivierung vollständig von der Elektrolytlösung abgeschirmt. Des Weiteren wird gezeigt, dass die Kante des Graphens durch elektrochemische Modifizierung kovalent funktionalisiert werden kann, wodurch die Ladungsdichte an der Graphenkanten-Flüssigkeits-Grenzfläche effektiv verändert wird. Dabei bleiben die vorteilhaften Eigenschaften der Devices erhalten. Schließlich wird ein neuartiger Ansatz zu Untersuchungen an der Graphenkante in Form von mit hexagonalem Bornitrid-verkapseltem Graphen-Elektroden verfolgt. Die elektroanalytische Detektion von Ferrocenmethanol und Dopamin an der Graphenkante mittels zyklischer Voltammetrie wird an diesen Elektroden gezeigt. / Several aspects of the design and function of sensors based on graphene operated in liquid have been investigated in this thesis, providing new insight into fundamental processes at the graphene-liquid-interface. First, the effect of the presence of redox active molecules in the analyte solution of electrochemically gated graphene FETs is explored. During operation, heterogeneous electron transfer may occur at relevant potentials leading to Faradaic currents at the graphene channel. These lead to doping-like shifts of the transfer curve of graphene, as the graphene-liquid-interface represents a partially polarizable electrode. Due to the origin of the shifts, this observation is termed “Faradaic effect”. It is fundamentally different from typically discussed transduction mechanisms. Parameters influencing the direction and magnitude of the Faradaic effect are discussed in detail, e.g. the shifts are the stronger, the larger the area of the graphene channel. The second part focuses on the edge of graphene, which represents a nanoscopic one-dimensional defect of the two-dimensional material. Here, a new type of graphene FET is introduced based on electrochemical gating of graphene exclusively via the electrical double layer at its edge. To achieve edge-gating, the basal part of graphene is passivated by a photoresist and shielded entirely from interaction with the solution. It is demonstrated that the edge of graphene can be functionalized covalently via electrografting. This changes the charge density at the graphene edge-liquid-interface effectively, while maintaining the favorable transfer characteristics of the devices. Finally, a novel approach towards graphene edge devices was pursued in the form of hexagonal boron nitride encapsulated graphene. The electrochemical detection of ferrocene methanol and dopamine was demonstrated in standard and fastscan cyclic voltammetry at the edge of graphene in these devices.

Page generated in 0.0562 seconds