• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 571
  • 11
  • 11
  • 11
  • 11
  • 11
  • 11
  • 10
  • 10
  • 7
  • 1
  • Tagged with
  • 584
  • 256
  • 128
  • 124
  • 86
  • 85
  • 84
  • 63
  • 61
  • 56
  • 54
  • 52
  • 45
  • 42
  • 40
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Laboratório Virtual versus Laboratório Material: a aprendizagem de física com intervenções tradicionais e investigativas

Xavier, Agamenon Pereira 10 August 2018 (has links)
Submitted by Agamenon Xavier (agapxavier@yahoo.com.br) on 2018-08-31T13:34:21Z No. of bitstreams: 1 Tese_Agamenon_Xavier_PPGEFHC.pdf: 4228684 bytes, checksum: 8252b4fe56b143b98504117665b8f3f1 (MD5) / Approved for entry into archive by NUBIA OLIVEIRA (nubia.marilia@ufba.br) on 2018-09-25T20:41:21Z (GMT) No. of bitstreams: 1 Tese_Agamenon_Xavier_PPGEFHC.pdf: 4228684 bytes, checksum: 8252b4fe56b143b98504117665b8f3f1 (MD5) / Made available in DSpace on 2018-09-25T20:41:21Z (GMT). No. of bitstreams: 1 Tese_Agamenon_Xavier_PPGEFHC.pdf: 4228684 bytes, checksum: 8252b4fe56b143b98504117665b8f3f1 (MD5) / A presente pesquisa investigou a aprendizagem de conteúdos formais de estudantes do Ensino Médio, contrapondo abordagens investigativas e tradicionais no laboratório virtual e material. Os métodos utilizados foram fundamentalmente quantitativos, pautados nos modelos probabilísticos e técnicas da modelagem Rasch, testes estatísticos, bem como na perspectiva de aprendizagem da teoria de habilidades dinâmicas. Participaram da pesquisa aproximadamente setecentos indivíduos, incluindo o primeiro momento de construção e validação dos instrumentos de intervenção e coleta de dados, e num segundo momento através das intervenções educacionais nas aulas de Física de doze turmas do Ensino Médio. Comparando os dados dos estudantes submetidos a diferentes abordagens, tivemos evidências de maior aprendizagem para aqueles participantes na abordagem investigativa comparada os estudantes submetidos à abordagem tradicional. Ao compararmos os dados dos estudantes participantes em diferentes ambientes, houve evidência de maior aprendizagem dos estudantes submetidos às intervenções no laboratório material, comparados àqueles submetidos a intervenção no laboratório virtual. Por sua vez, ao investigarmos os resultados dos estudantes submetidos a intervenções associando abordagem e ambiente, tivemos evidência que na abordagem tradicional, o laboratório material favorece mais a aprendizagem de conteúdo formal do que o laboratório virtual. Já com abordagem investigativa, houve indícios de que a aprendizagem de conteúdo formal é a mesma para a intervenção no laboratório material e virtual. Contudo, considerando o laboratório virtual, as evidências são de que a abordagem investigativa favorece mais a aprendizagem de conteúdo formal do que a abordagem tradicional. E por fim, tivemos indícios de que no laboratório material tanto a abordagem investigativa quanto a tradicional favorecem a aprendizagem de conteúdos formais da mesma maneira. / The present research investigated the learning of formal contents of students of High School, contrasting inquiry and traditional approaches in the virtual and material laboratory. The methods used were mainly quantitative, based on probabilistic models and techniques of Rasch modeling, statistical tests, as well as from the perspective of learning the Dynamic Skill Theory. Approximately 700 individuals participated in the study, including the first moment of construction and validation of intervention instruments and data collection, and secondly by means of the educational interventions in the physics classes of twelve high school classes. Measuring the data of students submitted to different approaches, we had evidence of greater learning for those participants in the comparative inquiry approach to the students submitted to the traditional approach. When we compare the data of the students who participated in different environments, we can find more evidences of learning in the students submitted to interventions in the material laboratory, in comparison to those submitted to intervention in the virtual laboratory. On the other hand, when we investigated the results of the students submitted to interventions that associate approach and environment, we had evidence that, in the traditional approach, the material laboratory favors more the learning of formal content than the virtual laboratory. Already with an inquiry approach, there were indications that the learning of formal content is the same for the intervention in the material and virtual laboratory. However, considering the virtual laboratory, it was conclude that the inquiry approach favors more formal content learning than the traditional approach. Finally, we have had indications that in the material laboratory the both inquiry approaches favor the learning of formal contents in the same way.
222

Avaliação dos parâmetros de compressibilidade da camada de argila mole da Baixada de Jacarepaguá, após longo período de sobrecarga de aterro. / Evaluation of Compressibility Parameters of a soft Clay layer at Baixada de Jacarepaguá after a long period of an embankment surcharge.

Bianca da Silva Baldez 30 August 2013 (has links)
Foram realizados ensaios de adensamento, SIC e CRS, em amostras retiradas de um depósito argiloso muito mole, na Baixada de Jacarepaguá, 15 anos após a execução de um aterro. As amostras foram retiradas do mesmo local onde foram obtidas as amostras da primeira campanha, por ocasião do projeto. Os ensaios CRS, realizados com diferentes velocidades de deformação, são comparados aos resultados dos ensaios SIC da campanha atual de investigação. Os parâmetros geotécnicos da camada de argila muito mole, 15 anos após a construção do aterro, são comparados aos parâmetros da camada original. O aumento das tensões de sobreadensamento e redução do OCR são obtidos da interpretação dos ensaios atuais. A grandeza do recalque foi inferida a partir da nova estratigrafia, através da espessura atual da camada na região investigada, pela variação do índice de vazios e pela variação do teor médio de umidade. Os recalques previstos originalmente, incluindo a parcela de compressão secundária, são comparados aos recalques inferidos e medidos através de placa de recalque. As principais conclusões da pesquisa sugerem que a qualidade dos corpos de prova da primeira campanha foram superiores aos atuais, apesar dos cuidados com a amostragem, transporte das amostras e preparação dos corpos de prova no laboratório na segunda campanha de ensaios. Atribuiu-se esta ocorrência ao processo construtivo, que impôs movimentação excessiva ao maciço argiloso, interferindo com suas características de maior uniformidade em seu processo de deposição natural. Os ensaios de adensamento com diferentes velocidades de carregamento apresentaram comportamento similar, com variação da posição relativa das curvas e x σv, com ensaios mais rápidos exibindo maiores índices de vazios. As curvas do índice de vazios versus tensão efetiva ilustram, de forma acentuada, a redução significativa do índice de vazios da segunda campanha em relação ao solo natural, antes do lançamento do aterro. Os recalques previstos e os obtidos, seja pela instrumentação, seja pelos demais registros, indicam valores bastante próximos, em face da variabilidade da estratigrafia e dos parâmetros geotécnicos inerentes à natureza dos depósitos sedimentares. / SIC and CRS consolidation tests have been performed on samples obtained from a very soft clay deposit from Jacarepaguá lowland, 15 years after the execution of a fill. The samples have been extracted from the same site where preliminary samples had been obtained at designing phase. The CRS tests have been performed at different strain velocities and compared to the SIC tests results carried out for the second investigation campaign. The geotechnical parameters of the very soft clay 15 years after fill construction are compared to the parameters of the natural shallow clay. The increase in pre-consolidation pressure and OCR reduction has been obtained after interpretation of the actual tests results. The settlement extent has been inferred from the new stratigraphy, due to the actual thickness of the layer in the investigated region, by the variation in void ratio and by the reduction in soil water content. The settlements originally predicted, including the secondary compression, are compared to the settlement obtained from different estimations and to those obtained from instrumentation. The main conclusions suggest that the sample quality from the first investigation were superior than from the actual one, in spite of the careful sampling, transportation and preparation in the laboratory for the second investigation campaign. This occurrence has been attributed to the construction process, imposing excessive movement of the clayey mass, with great interference on the uniformity of its characteristics when compared to its natural deposition. The consolidation tests with different strain velocity presented similar results, with variation in the relative position of the e x σv curve, with the tests with higher strain velocity showing higher void indices. The e x σv curves illustrate in an accentuated means the significant reduction in void ratio from the first to the second laboratory test campaign, due to the fill construction. The predicted settlements and that actually obtained by the instrumentation or by other sources indicate similar values compared to the stratification variability of the geotechnical parameters inherent to the natural origin of the sedimentary deposits.
223

Gestão de resíduos químicos em laboratório universitário. Estudo de caso: Laboratório de Engenharia Sanitária, Faculdade de Engenharia UERJ. / Chemical waste management in the university laboratory. A case study: Laboratory of Sanitary Engineering, Faculty of Engineering - UERJ.

Patrizzia Cappelletti Rocha 23 February 2011 (has links)
Ao longo da história do homem, as universidades têm exercido um papel fundamental na geração de conhecimentos e tecnologias com o fim maior de melhorar a qualidade de vida de nossa sociedade. Em contrapartida, além de produzir os benefícios oriundos da aplicação dos conhecimentos e tecnologias, as pesquisas científicas produzem também diversos tipos de resíduos potencialmente poluidores e tóxicos os quais não estão sendo descartados e tratados corretamente. A falta de políticas institucionais de gerenciamento de resíduos nas universidades além de proporcionar a poluição dos corpos receptores de seus efluentes, a deterioração das tubulações coletoras de esgoto e, danos a eficiência das estações de tratamento de esgoto, também contribui para a geração de um passivo ambiental nas universidades, os quais são acumulados anualmente à espera de tratamento adequado em precárias condições de armazenamento. Dentro deste cenário, o presente estudo visa caracterizar e avaliar o gerenciamento dos resíduos químicos do Laboratório de Engenharia Sanitária (LES) da Universidade do Estado do Rio de Janeiro (UERJ). Quanto aos meios, foram realizadas pesquisas bibliográficas, eletrônicas e documentais, assim como entrevistas com os principais atores do gerenciamento dos resíduos no laboratório foco deste estudo. O estudo revela que o gerenciamento dos resíduos gerados em tal laboratório é realizado de maneira incipiente. As metodologias utilizadas em todas as etapas do gerenciamento, desde a geração dos resíduos até a destinação final dos mesmos carecem de melhorias para também a melhora da qualidade ambiental das atividades de pesquisa e de ensino do laboratório. Além da inexistência de normas internas para a padronização e controle do processo de gerenciamento, o laboratório também carece de estrutura física e financeira para a adequação do processo. A partir do diagnóstico deste cenário, foi possível o reconhecimento de riscos relacionados às características dos reagentes químicos somados as condicionantes ambientais do laboratório, mais especificamente, às condicionantes presentes no local do armazenamento dos resíduos. Tais riscos possuem a natureza de riscos químicos, físicos, toxicidade e riscos de explosão. Ainda na caracterização deste cenário, foi possível o reconhecimento do não cumprimento de legislações pertinentes ao tema. Conclui-se que, de maneira geral, as universidades carecem de investimentos na temática de gestão ambiental nas políticas institucionais e dia-a-dia das universidades. O laboratório em questão também não foge a esta realidade e, por tal razão, também carece de investimentos financeiros, investimentos em treinamento e investimentos na estruturas físicas para todos estes darem suporte a implantação de um gerenciamento de resíduos eficiente e consistente. / Along the human history, universities have had a fundamental role on the knowledge and technology generation to apply them to improve our society quality. In other hand, to provide these results, scientific research produces various kinds of wastes and toxic pollutants which are not disposed properly. The absence of waste management institutional policies in universities provides the pollution of effluent receiving bodies (water resources), deterioration of pipes and sewage systems, affect the efficiency of sewage treatment plants and also contributes to the generation of passives environmental in universities which the amount of chemical waste generated expects for appropriate treatment in precarious storage conditions. On this background, this paper aims to characterize and evaluate the Laboratory of Sanitary Engineering (SLE) chemical waste management located at State University of Rio de Janeiro (UERJ). The applied metodology, used literature searches, and electronic documents, as well as interviews with management laboratorys waste responsible observation on site. This case study aimed to characterize and evaluate the procedures for chemical waste management of LES in order to propose improvements in such management. The study reveals that management of waste generated on this lab is performed inchoately. The used methods in all phases of management, from the generation of waste to dispose of them need to be improved to also improve the quality of environmental research and teaching laboratory. In addition to the absence of internal standardization norms and absence of the management process control, the lab also lacks the physical and financial structure to adequate the management process. Since this scenario diagnosed, it was possible to recognize the risks associated with chemical reagents characteristics summed the environmental conditions of the laboratory, more specifically, the constraints on site storage of waste. These risks have the nature of chemical, physical, toxicity and explosion hazards risks. Still on the characterization this scene, it was possible the recognition of non-compliance laws relevant to scenario. This paper conclusion is that, in general, universities need more investment in the theme of environmental management in an institutional way. The studied laboratory also does not escape this reality and dust that reason, also lacks financial investments, investments in training and investment in physical infrastructure in the laboratory for all these give support to the deployment of an effective waste management and consistent.
224

O laboratório de ensino de matemática nas práticas do 4º ciclo do ensino fundamental

Bermudes, Filipe Pinel Berbert 04 April 2014 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2014-12-16T18:59:36Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.Filipe Pinel Berbert Bermurdes.texto completo.pdf: 2316820 bytes, checksum: b5b0774c7ab1e082f6ca73dadda930e1 (MD5) / Approved for entry into archive by Elizabete Silva (elizabete.silva@ufes.br) on 2014-12-19T18:20:30Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.Filipe Pinel Berbert Bermurdes.texto completo.pdf: 2316820 bytes, checksum: b5b0774c7ab1e082f6ca73dadda930e1 (MD5) / Made available in DSpace on 2014-12-19T18:20:31Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao.Filipe Pinel Berbert Bermurdes.texto completo.pdf: 2316820 bytes, checksum: b5b0774c7ab1e082f6ca73dadda930e1 (MD5) Previous issue date: 2014 / Nem sempre a Matemática é vista de forma favorável pelos alunos do Ensino Fundamental. Na realidade, o que temos observado na prática, é que toda turma que conhecemos apresenta um grupo significativo de alunos com preconceitos e resistência a respeito do que acreditam ser a Matemática. Isso tem motivado algumas reflexões, alguns estudos e algumas experiências de vários autores e professores acerca do Ensino. Dentre elas, destacam-se as práxis de laboratório para o ensino da Matemática. Em particular, pretendo abordar as práticas de Laboratório de Matemática para o 8º e 9º ano do Ensino Fundamental, o chamado 4º ciclo, principalmente pela disponibilidade do material humano (alunos/turmas de 8º e 9º ano) a quem tenho tido por anos a oportunidade de lecionar. Como paralelo ao trabalho que venho propor está o livro didático que temos adotado nos últimos anos, Matemática Bianchini de Edwaldo Bianchini. Ele será minha referência ao propor as práticas complementares em laboratório nos quatro grandes eixos de estudo da Matemática do Ensino Fundamental: Números e Operações, Espaço e Forma, Grandezas e Medidas e Tratamento da Informação. Frente a tal desafio, foram utilizados, como referencial teórico, Mendes, Almeida, Lachinni, Polya, os Parâmetros Curriculares Nacionais entre outros, complementando-se com literatura digital publicada na internet em forma de artigos, monografias, etc.
225

Verificação do desempenho do ensaio de adensamento CRS comparado ao SIC. / Cheking the performance of consolidation test CRS compared to SIC.

Karina Almeida Vitor 30 November 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A presente dissertação objetiva a verificação do desempenho dos ensaios do tipo CRS, com velocidade controlada, quando comparados aos ensaios de adensamento oedométricos convencionais, SIC. O ensaio SIC é executado em vários estágios de carga, cada qual com vinte e quatro horas de duração e razão unitária entre o incremento de tensão e a tensão anterior, requerendo um prazo total de cerca de 10 dias para sua execução. Já o ensaio de adensamento com velocidade controlada, CRS, tem sua duração bastante reduzida, o que levou diversos pesquisadores da área de Geotecnia a concentrarem esforços no estudo de seu desempenho, visando sua utilização mais ampla. Para este estudo foi adquirido equipamento da empresa Hogentogler Inc., designado por GeoStar. Sua instalação, montagem e calibração foram realizadas no Laboratório de Mecânica dos Solos. Foram executados ensaios em corpos de prova obtidos de amostras de caulim, preparadas em laboratório, e também em amostras de solos originários de dois depósitos de diferentes regiões no Estado do Rio de Janeiro: baixada de Jacarepaguá e Itaboraí. A dissertação procurou detalhar a execução dos ensaios, as dificuldades da interpretação das planilhas originadas pelo sistema de aquisição de dados, acoplado ao equipamento GeoStar, as mudanças efetuadas, as ocorrências não previstas, a análise e interpretação dos resultados e a comparação dos parâmetros obtidos com os ensaios SIC e CRS. Procurou-se estudar o efeito da velocidade de deformação, histórico de tensões, qualidade dos corpos de prova, parâmetros do ensaio, facilidade de execução e desempenho. Verificou-se a simplicidade, rapidez e o desempenho satisfatório do ensaio CRS. Sugere-se estender estudos semelhantes a outros locais e, principalmente, a amostras de qualidade superior, na expectativa de confirmar as conclusões detalhadas nesta pesquisa. / This thesis aims to check the performance of the constant rate of strain consolidation test, CRS, compared to the conventional oedometer test, SIC. The SIC test is usually performed in several load stages with load increment of unity, each stage left on for 24hr. The test duration last nearly 10 days. On the other hand, the constant rate of strain consolidation test, CRS, is performed in a much shorter interval. This aspect led many geotechnical researchers to focus efforts in studying the CRS performance, aiming their wider use in practice. The CRS equipment called GeoStar of Hogentogler Inc. has been imported from EUA for the use in this research. Its installation, assembly and calibration have been carried out in the laboratory of Soil Mechanics. CRS and SIC tests have been performed in caulim specimens, molded in the laboratory, and also in soil samples from two deposits of different sites in Rio de Janeiro State: Jacarepaguá and Itaboraí. The author attempted to detail the tests procedures, the difficulties of interpreting the worksheets that come along with the data acquisition system, necessary changes made in the worksheets, the unforeseen events, analysis and interpretation of results and comparison of the parameters obtained with the SIC and CRS tests. The author studied the effect of strain rate, tension history, sample disturbance, test parameters, ease of execution and test performance. The simplicity, short duration and satisfactory performance of CRS tests have been observed. The author suggests the extension of the studies to other sites, and especially the extraction of higher quality samples, hoping to confirm the findings detailed in this research.
226

Estudo dos efeitos oxidantes sobre a resposta inflamatória pulmonar em ratos expostos a diferentes concentrações de formaldeído.

Murta, Giselle Luciane January 2015 (has links)
Programa de Pós-Graduação em Ciências Biológicas. Núcleo de Pesquisas em Ciências Biológicas, Pró-Reitoria de Pesquisa e Pós Graduação, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2015-04-30T16:38:37Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_EstudoEfeitosResposta.pdf: 2201627 bytes, checksum: 51d5fa9566e6d964416a0a539ec8cb81 (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2015-04-30T16:48:51Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_EstudoEfeitosResposta.pdf: 2201627 bytes, checksum: 51d5fa9566e6d964416a0a539ec8cb81 (MD5) / Made available in DSpace on 2015-04-30T16:48:51Z (GMT). No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) DISSERTAÇÃO_EstudoEfeitosResposta.pdf: 2201627 bytes, checksum: 51d5fa9566e6d964416a0a539ec8cb81 (MD5) Previous issue date: 2015 / O aumento da morbidade e da mortalidade de doenças inflamatórias no trato respiratório tais como asma, enfisema e bronquite têm sido correlacionadas com a exposição de indivíduos a poluentes ambientais incluindo matéria particulada e substâncias químicas como o formaldeído (FA). O FA é um agente de ligação cruzada que reage com macromoléculas celulares, tais como proteínas, ácidos nucléicos e moléculas com baixo peso molecular, tais como aminoácidos, e tem sido relacionado a processos inflamatórios, bem como ao estresse oxidativo. O presente estudo teve como objetivo analisar os efeitos oxidantes sobre a resposta inflamatória pulmonar em ratos Fischer expostos a diferentes concentrações de FA. Para isso, vinte e oito ratos Fischer foram divididos em quatro grupos, com sete animais por grupo. O grupo controle (GC) foi exposto ao ar ambiente e três grupos foram expostos a diferentes concentrações de FA a 1% (FA1), 5% (FA5) e 10% (FA10). Após a eutanásia, foram coletados o sangue, o lavado broncoalveolar (LBA) e os pulmões para as análises bioquímicas e morfométricas. O LBA mostrou que a exposição ao formaldeído por cinco dias foi capaz de aumentar a quantidade de células inflamatórias nos pulmões dos ratos expostos ao formaldeído a 10% em relação ao GC. Mudanças também foram observadas no perfil celular em FA5 e FA10 com um aumento de macrófagos e linfócitos em FA10 e linfócitos em FA5 em relação ao GC. A atividade da NADPH-oxidase no sangue apresentou-se elevada em FA5 e FA10 em relação ao GC e houve aumento na produção de quimiocinas pró-inflamatórias (CCL2, CCL3 e CCL5) no plasma de animais dos grupos expostos ao FA. A atividade da enzima superóxido dismutase (SOD) apresentou aumento e a relação glutationa reduzida/oxidada (GSH/GSSG) apresentou redução em FA5 e a atividade da enzima catalase (CAT) apresentou aumento no grupo FA1, ambos em relação ao GC. Houve aumento na peroxidação lipídica e na formação de proteína carbonilada em FA10 em relação ao GC. Também observamos aumento nas quimiocinas CCL2 e CCL5 nos grupos expostos em relação ao GC. Quanto às análises morfométricas, o FA5 apresentou um aumento na área de luz alveolar (Aa) e uma redução na densidade de volume (Vv) de septo alveolar em relação ao GC. Nossos resultados apontam para o potencial do formaldeído em promover a lesão de vias aéreas tanto pelo aumento do processo inflamatório quanto pelo desequilíbrio redox. __________________________________________________________________________ / ABSTRACT: The increased morbidity and mortality of inflammatory diseases such as asthma, bronchitis and emphysema in the respiratory tract have been correlated with the exposure of individuals to environmental pollutants including particulate matter and chemical substances such as formaldehyde (FA). The FA is a crosslinking agent that reacts with cellular macromolecules such as proteins, nucleic acids and molecules with low molecular weight such as amino acids, and it has been linked to inflammatory processes and oxidative stress. This study aimed to analyze the oxidative effects on pulmonary inflammatory response in Fischer rats exposed to different concentrations of FA. Twenty-eight Fischer rats were divided into four groups with seven animals per group. The control group (CG) was exposed to ambient air and three groups were exposed to different concentrations of FA 1% (FA1), 5% (FA5) and 10% (FA10). Blood, bronchoalveolar lavage (BAL) and lungs were collected for biochemical and morphometric analyzes after euthanasia. The BAL fluid showed that exposure to formaldehyde for five days was able to increase the amount of inflammatory cells in the lungs of rats exposed to formaldehyde 10% in comparison to the CG. Changes were also observed in FA5 and FA10 cell profiles with an increase of macrophages and lymphocytes in FA10 and lymphocytes in FA5 compared to the CG. The activity of NADPH oxidase in the blood had been higher in FA5 and FA10 compared to the CG and there was increased production of pro-inflammatory chemokines (CCL2, CCL5 and CCL3) in the plasma of groups exposed to FA. The activity of superoxide dismutase enzyme (SOD) had an increase and reduced/oxidized glutathione ratio (GSH / GSSG) had an decrease in FA5 and the activity of the catalase enzyme (CAT) showed an increase in FA1 group, both in relation to the CG. There was an increase in lipid peroxidation and protein carbonyl formation in FA10 compared to the CG. We also observed an increase in CCL2 and CCL5 chemokines in the treatment groups compared to the CG. As for the morphometric analysis, the FA5 showed an increase in the alveolar area (Aa) and a reduction in volume density (Vv) of the septal compared to the CG. Our results point out to the potential of formaldehyde in promoting airway injury by increasing the inflammatory process as well as by the redox imbalance.
227

ESTUDO DA CONDUTIVIDADE HIDRÁULICA DE SOLOS PARA A DISPOSIÇÃO DE RESÍDUOS SÓLIDOS NA REGIÃO DE SANTA MARIA / STUDY OF THE HYDRAULIC CONDUCTIVITY OF SOILS FOR DISPOSAL OF SOLID WASTE IN THE REGION OF SANTA MARIA

Pinto, Juliane dos Santos 22 December 2005 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The study of hydraulic conductivity of soil is an important stage in the geotecnical investigations, aiming at the use of compacted soils as impermeabilizing mineral layers, for the base and cover of sanitary land-fill sites. This paper presents the study of hydraulic conductivity (k) of natural and compacted soils of the Santa Maria region, in the area called Caturrita which was chosen for the future installation of the sanitary land-fill of this city, localized near the current solid waste disposal site of Santa Maria (Robaina, 2002). In this place a detailed geological-geotecnical investigation was undertaken. The objective of this investigation was the identification, classification and characterization of the soils of seventeen drilling profiles (P1 to P17) distributed in the area of study; the majority were executed with a manual boring-tool, of which samples were collected for laboratory tests. For all profiles characterization tests were performed (Atterberg limits, granulometric analysis, density of grains). In one typical profile (P1) complementary tests were made such as, chemical tests, X-ray diffraction, compaction and hydraulic conductivity tests with of rigid and flexible walls permeameters. For this study of hydraulic conductivity a flexible wall permeameter with a simplified triaxial chamber was assembled similar to that of Bjerrum and Huder (1957). In situ tests were performed of the following type: infiltration hole, ring infiltrometer, and piezometer, which evaluated the characteristics of soil in its natural condition. Through the investigations two layers (layers 1 and 2) were identified in this area. Layers 1 are more superficial, and constituted of horizon A and finally horizon B. In the lower layer 2 (horizon C), with a reddish colour, the soil shows characteristics of alteration of sedimentary rocks. The results of in situ tests k show similar values between each other, because the infiltration tests have values of k in the order of 10-5 m/s, in the same order of magnitude as the results with piezometer in layer 1. The values of k of layer 2 were in the order of 10-7 and 10-8 m/s in the natural state. The compacted samples had values of k in the order 10-9 and 10-10 m/s. The results of k in the flexible wall permeameter were higher for undisturbed samples, and compacted samples resulted in values in the order of 10-9 m/s. Values of k of this order are indicated as natural impermeabilizing barriers in sanitary land-fills. / O estudo da condutividade hidráulica de solos é uma etapa importante nas investigações geotécnicas, visando a utilização de solos compactados como camadas impermeabilizantes minerais, para base e revestimento de cobertura de aterros sanitários. Este trabalho apresenta o estudo da condutividade hidráulica (k) de solos naturais e compactados da região de Santa Maria, na área denominada Caturrita, a qual foi pré-selecionada como futura instalação do aterro sanitário desta cidade, localizada próximo ao atual local do depósito de resíduos sólidos de Santa Maria, o chamado lixão da Caturrita (Robaina, 2002). Neste local foi realizada uma investigação geológica-geotécnica detalhada. Esta investigação teve como objetivo a identificação, classificação e caracterização de solos através de 17 perfis (P1 a P17) de sondagem distribuídos na área do empreendimento, na maioria executados com trado manual, dos quais coletaram-se amostras para ensaios de laboratório. Em todos os perfis foram realizados ensaios de caracterização (limites de Atterberg, granulometria com e sem defloculante e peso específico real dos grãos). Em um perfil típico (P1) foram realizados ensaios complementares, tais como: ensaios químicos, difração de raios-X, ensaios de compactação e condutividade hidráulica com permeâmetro de parede flexível. Para o estudo da condutividade hidráulica foi montado para esta pesquisa o permeâmetro de parede flexível com câmara triaxial simplificada, similar ao proposto por Bjerrum e Huder (1957). In situ foram realizados ensaios do tipo: cava de infiltração, infiltrômetro de anel, e com a técnica do piezômetro, os quais avaliam as características do solo em condições naturais. Através das investigações foram identificadas na área duas camadas (camadas 1 e 2) para os perfis de solo, sendo que a camada 1 mais superficial é constituída por um horizonte A e eventualmente um horizonte B. Na camada 2 (horizonte C) mais inferior, com coloração avermelhada, possui características de alteração de rochas sedimentares. Os resultados dos ensaios k in situ apresentaram valores semelhantes entre si, sendo que o ensaio de infiltração teve valores na ordem de 10-5 m/s, na mesma ordem dos resultados com piezômetro na camada 1. A camada 2 os valores de k foram da ordem de 10-7 e 10-8 m/s no estado natural. Os corpos compactados tiveram valores de k na ordem 10-9 a 10-10 m/s. Os resultados de k em permeâmetro de parede flexível foram mais elevados para amostras indeformadas, e nos corpos de prova compactados resultaram valores na ordem de 10-9m/s. Valores de k desta ordem são indicados como barreiras naturais impermeabilizantes em aterros sanitários.
228

Perfil eletroforético e cromatográfico das hemoglobinas S-like

Ondei, Luciana de Souza [UNESP] 29 August 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-08-29Bitstream added on 2014-06-13T20:33:44Z : No. of bitstreams: 1 ondei_ls_me_sjrp.pdf: 1659909 bytes, checksum: 0234670a460d2993f23cb77243c91e66 (MD5) / As hemoglobinas (Hb) variantes, originadas em sua maioria por simples substituições de aminoácidos, resultam de mudanças na seqüência de nucleotídeos. Atualmente, o número de Hb anormais identificadas tem aumentado devido à melhoria nas metodologias de análises, porém muitos laboratórios de rotina não estão preparados para a correta identificação dos mutantes. A Hb S é uma variante de Hb bem caracterizada que apresenta prevalência variável nas diferentes regiões do Brasil. No entanto, há uma variedade de Hb que apresenta padrão de migração eletroforética semelhante ao da Hb S em pH alcalino as quais são denominadas “Hb S-like”, podendo ser erroneamente diagnosticadas e com suas freqüências subestimadas. Neste trabalho foram estabelecidos os valores referenciais de Hb por HPLC em portadores de Hb S e determinados os perfis eletroforético e cromatográfico das Hb “S-like” dentre as amostras enviadas ao LHGDH. Foram encontradas as Hb Hasharon, Hb D-Los Angeles, Hb Korle-Bu, Hb Lepore, Hb D-Iran, Hb tipo G, Hb Queens, Hb Montgomery e Hb Q-Índia. Também foram encontrados casos de associação entre dois mutantes de cadeia beta. As eletroforeses em pH alcalino e pH ácido foram utilizadas para o rastreamento inicial das Hb variantes e as eletroforeses de cadeias polipeptídicas em ambos pH foram realizadas para a identificação da cadeia globínica alterada. As análises cromatográficas permitiram o direcionamento dos prováveis mutantes, sendo também possível a quantificação precisa das frações de variantes. Desta forma, a associação de metodologias laboratoriais clássicas de diagnóstico é fundamental para o levantamento das suspeitas fenotípicas. Os perfis da Hb S e das Hb “S-like” estabelecidos neste estudo auxiliarão no diagnóstico dessas Hb variantes em serviços de saúde. / The variants hemoglobin (Hb) originated mainly by simple amino acid substitutions, result of nucleotides sequences changes. Currently, the number of abnormal hemoglobin identified has increased due to improvement in the analysis methodologies, but many routine laboratories are not prepared for the correct mutants identification. The Hb S is a variant Hb well characterized that shows variable prevalence in different regions of Brazil. However, there is a diversity of Hb that present electrophoretic migration on alkaline pH similar to Hb S, named Hb S-like, which can be incorrectly diagnosed and with their frequencies underestimated. At the present study the reference ranges for Hb S obtained by HPLC were established, and the electrophoretic and cromatographic profile for Hb S like were determined. The Hb Hasharon, Hb D-Los Angeles, Hb Korle-Bu, Hb Lepore, Hb D-Iran, Hb tipo G, Hb Queens, Hb Montgomery e Hb Q-Índia were found. Cases of association between two mutants of beta chain were also found. The electrophoresis on alkaline pH and acid pH were utilized to the initial screen of these variants Hb and the globin chains electrophoresis in both pH were performed to identify the mutant globin chain. The chromatographic analysis permitted the identification of the likely variant hemoglobin and also facilitated the exact quantification of variants. Therefore, the association of the classical laboratory methods of diagnostic is fundamental for the identification of variant Hb suspect. The Hb S and Hb S-like profile determined in this study will help in the diagnostic of these variants Hb in healthy service.
229

Avaliação de métodos para tratamento de resíduos químicos originados em laboratórios biológicos

Fonseca, Janaína Conrado Lyra da [UNESP] 19 April 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-04-19Bitstream added on 2014-06-13T20:26:03Z : No. of bitstreams: 1 fonseca_jcl_dr_araiq.pdf: 990419 bytes, checksum: e085f09b617e177af79386bb8d35d879 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Substâncias perigosas são freqüentemente utilizadas em laboratórios de ensino e pesquisa das Universidades. Até pouco tempo não existia preocupação com o destino destas substâncias após o uso. Tinha-se a falsa idéia de que como a Universidade utiliza poucas quantidades, de diferentes produtos, seu efeito ao ambiente era irrelevante. Felizmente atualmente este cenário é outro e as Universidades estão implementando programas de gerenciamento e em alguns poucos casos, de tratamento de resíduos. Diferentemente de agentes biológicos, substâncias químicas não possuem um procedimento de degradação que seja eficaz às diferentes classes e é necessário o desenvolvimento de diferentes métodos para diferentes produtos. Este trabalho adaptou métodos degradativos apresentados na literatura à três substâncias, escolhidas por sua toxicidade e pelo volume gerado anualmente das mesmas: brometo de etídeo (BE), formaldeído e fenol. A degradação do BE foi monitorada por fluorescência e pela concentração de Carbono Orgânico Total (COT), como BE é mutagênico seu produto de degradação foi submetido ao teste de mutação gênica com Salmonella thiphimurium (teste de Ames) utilizando as linhagens TA97a, TA98 e TA100, para avaliar se havia perdido esta característica. Observou-se que embora todos os tratamentos apresentassem a mesma resposta quanto a fluorescência, o ensaio mutagênico mostrou que apenas dois procedimentos poderiam ser realmente empregados. Os demais resíduos (fenol e formaldeído) tiveram seus produtos de degradação avaliados por COT e segundo as premissas da legislação estadual para efluentes em ambos os casos os resíduos apresentaram uma boa redução da carga orgânica. A toxicidade dos produtos formados foi avaliada por testes ecotoxicológicos (Daphna magna) e como todo formaldeído e fenol foram oxidados essa propriedade foi efetivamente eliminada. / Hazardous substances often have been used in university teaching and researching laboratories as well. Few years ago there was not the concern about the destiny of these substances after their application. There was the wrong concept as the university use a few quantities of different kind of products, the behavior of these products in the environment were insignificant. Fortunately, nowadays the context has changed and the universities have established management programs of waste treatment. Distinctly of biological agents, chemicals substances do not have a model is better (or pattern) of destruction efficient to so many categories or types. So it is necessary the development of different methods for different products. This present work adjusted degradative methods presented on the literature for three different substances, chosen by their toxicity and quantity yearly storage: ethidium bromide (EB); formaldehyde and phenol. The degradation of EB was observed by fluorescence and by total carbon organic concentration, as BE is mutagenic, its degradation product was submitted to mutagenicity test with Salmonella thiphimurium (Ames test) using TA97a, TA98 and TA100, for evaluate original characteristics. The obtained data shown that although all of treatments presented the same answer for the fluorescence, the mutagenic assay has shown that just two methods could be efficiently used. The another products (phenol and formaldehyde) have had yours degradatives products evaluated by TOC according the supposition from the state legislation for wastewater, in both cases the results data shown reduction organic The toxicity of products in this case were evaluated by ecotoxicological tests (Daphnia magna), as all formaldehyde and phenol have been oxidized the toxicity was banished. Even tough the results obtained shown that methods are simple and could be applied for own creators in situ, just follow the methods shown in these work.
230

Associação entre os níveis de D-dímero, produtos de degradação da fibrina/fibrinogênio (PDF) e troponina cardíaca T na investigação dos distúrbios tromboembólicos

Moresco, Rafael Noal January 2005 (has links)
Resumo não disponível

Page generated in 0.2755 seconds